Turn OFF the power and remove the old thermostat 1 4 Complete installation 5 Prepare Receiver Box for installation 2 Install the Receiver Box 3 T T T T S S A) B) B) Surface wiring C) Replace the cover Connect 2 thermostat wires to the T and T terminals and close cover. Remember to use the same wires that you connected to the Receiver Box when connecting to the thermostat. min 0.25mm 2 max 1.5mm 2 To ensure your safety, always make sure mains power is switched OFF before accessing wiring. Before removing the old thermostat take a picture of the old thermostat’s wiring as reference then proceed to installation. Needed during installation: Cable with 2 wires from the Receiver Box (R4H810A) to thermostat. Cable with 2 wires from the boiler to Receiver Box. The Receiver Box requires 230V power The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 - 1.5 meters from the floor. Maximum cable length between Receiver box and thermostat: 15m for 0.5mm² cable or 20m for 1.0mm² cable. WEEE Directive 2012/19/EC Waste Electrical and Electronic Equipment directive At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product. Must be installed by a competent person! Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Before installation of the Receiver Box Find a suitable location near to the boiler. Loosen the front screw to remove cover or tighten it when the cover is back in place. Using a screwdriver open wallplate terminal cover to connect wires Max 6 mm Please refer to the wiring diagrams over the page Optional Coverplate installation 1.2-1.5 m C) Attach the thermostat to the wallplate when finished. After powering up both devices the green LED is on. Turn ON mains power to the Heating Appliance and Receiver Box. Push the button to check if the boiler switches on. Button lights green. After power up, SETUP is displayed on the thermostat’s screen. A) Wall box or Rear Wiring Hinge open the terminal block flap to access the cables and wall box screw holes. Use the cable clamps to secure the surface wiring. Locate the hinges at the top of the cover and wall plate, close the cover and secure with the screw. Install the T6 thermostat Compatible with 24-230V on/off and OpenTherm® appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with electric heating (240V). Need help? For assistance please visit: getconnected.honeywellhome.com 200 Berkshire Place, Winnersh Triangle Berkshire RG41 5RD Phone: 0300 130 1299 Approvals Hereby, Pittway Sarl declares that the radio equipment type T6H700RW is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://hwllhome.co/DoC Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHz ErP: Class V (+3%), (EU) 811/2013 T6 Smart Thermostat EN Installation Manual 32308180-001 F

Upload: others

Post on 01-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: T6 Smart Thermostat - Honeywell Home · 2020. 11. 24. · The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2

Turn OFF the powerand remove the old thermostat1

4 Completeinstallation5

Prepare Receiver Boxfor installation2 Install the

Receiver Box3

TTT

TSS

A) B)

B) Surface wiring

C) Replace the cover

Connect 2 thermostat wires to the T and T terminals and close cover.

Remember to use the same wires that you connected to the Receiver Box when connecting to the thermostat.

min 0.25mm2 max 1.5mm2

To ensure your safety, always make sure mains power is switched OFF before accessing wiring.

Before removing the old thermostat take a picture of the old thermostat’s wiringas reference then proceed to installation.

Needed during installation:

Cable with 2 wires from the Receiver Box (R4H810A) to thermostat.

Cable with 2 wires from the boiler to Receiver Box.

The Receiver Box requires 230V power

The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 - 1.5 meters from the floor.

Maximum cable length between Receiver box and thermostat:15m for 0.5mm² cable or 20m for 1.0mm² cable.

WEEE Directive 2012/19/EC Waste Electrical and Electronic Equipment directive

At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.

Must be installed by a competent person!Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

Before installation of the Receiver Box

Find a suitable location near to the boiler.

Loosen the front screw to remove cover or tighten itwhen the cover is back in place.

Using a screwdriver open wallplate terminal cover to connect wires

Max 6 mm

Please refer to the wiring diagrams over the page

Optional Coverplate installation

1.2-1.5 m

C) Attach the thermostat to the wallplate when finished.

After powering up both devices the greenLED is on.

Turn ON mains power to the Heating Appliance and Receiver Box.

Push the button to check if the boiler switches on.Button lights green.

After power up, SETUP is displayedon the thermostat’sscreen.

A) Wall box or Rear WiringHinge open the terminal block flap to access the cables and wall box screw holes.

Use the cable clamps to secure the surface wiring.

Locate the hinges at the top of the cover and wall plate, close the cover and secure with the screw.

Install theT6 thermostat

Compatible with 24-230V on/off and OpenTherm® appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with electric heating (240V).

Need help? For assistance please visit: getconnected.honeywellhome.com

200 Berkshire Place, Winnersh TriangleBerkshire RG41 5RDPhone: 0300 130 1299

ApprovalsHereby, Pittway Sarl declares that the radio equipment type T6H700RW is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://hwllhome.co/DoC

Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHzErP: Class V (+3%), (EU) 811/2013

T6 Smart ThermostatEN Installation Manual

32

30

81

80

-00

1 F

Page 2: T6 Smart Thermostat - Honeywell Home · 2020. 11. 24. · The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2

Set Up andconfiguration6

Wiring Diagrams

A) Wiring forbasic 230Vboiler

B) Wiring forCombi boiler

C) Wiring forOpenThermboiler

D) Wiring fortwo-portzone valve

Boiler

Receiver Box

s s

ThermostatReceiver Box

T1 T2

Boiler*

s s

Thermostat

Receiver Box

Boiler*

s s

Thermostat

T1 T2

Receiver Box

s s

Thermostat

V4043

For other wiringdiagrams visit:

Lyric

Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds.

In the advanced menu the following settings can be adjusted:

AMPM

AM

PM

AM

PM

*1234

1 2 3 4 5 6

*****230****

5 sec

LANGUAGE

OPENTHERM

CYCLE RATE

MINIMUM ON TIME

HEAT RANGE

SCHEDULE OPTIONS

OPTIMISE

CLOCK

LOW LOAD CONTROL

TEMPERATURE OFFSET

RESET

FAILSAFE

English

6

ON 0 = OFF, 1 = ON

OFF

-

-

0 = OFF, 1 = ON

0.0ºC -1.5 ºC to 1.5ºC

Factory, schedule, WiFi and HomeKit reset

Clock format: 1 = 12h, 2 = 24hSetup time and date

1 minute

3, 6, 9 or 12

Daily

Opt. start OFFOpt. stop OFF

Opt. start: 0 = OFF, 1 = ON, 2 = Delayed startOpt. stop: 0 = OFF, 1 = ON

Format: 24hTime: --:--Date: 01/09/16

1, 2, 3, 4 or 5 minutes

Min = 5.0ºCMax = 35.0ºC

1 = Daily schedule, 2 = 5+2 days schedule

Min: 5ºC to 21ºC, Max: 21ºC to 35ºC

Menu Item Default Options0 = English, 1 = Français, 2 = Español3 = Deutsch, 4 = Nederlands, 5 = Italiano

OpenTherm boiler data when available

EXTERNAL SENSOR No sensor 0 = No sensor, 1 = Room sensor

4) Touch to finalise setup.

( to setup using the App is currently unsupported)

***SETUP****

SETUP

**LANGUAGE**

*CLOCK

SETUP

1) Touch to begin setting up the thermostat.

2) Select your language.

3) Set the clock format, time and date.

SETUP

CONFIGURE W

https://hwllhome.co/uk-wiring

Pittway Sarl, Z.A. La Pièce 41180 Rolle, Switzerland

* See boiler specificationsfor correct terminals

Country of origin : UK

© 2020 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International Inc. This product is manufactured by Resideo and its affiliates.