    TransAccess 200

    Quick Start GuideCongratulations on your purchase of theTransAccess 200. This Quick Start

    Guide describes the steps necessary to

    unpack, install, and initialize your new

    equipment. It is strongly recommended

    that you read this entire document beforeproceeding.

    ________________________________________________________________

    Rev. 4 940-00008-002

    This document is supplemental to the full

    Operations Manual for the TransAccess 200.

    ____________________________________________________________

    08/03/04

  • 8/9/2019 TA 200 Quick Start R4

    2/12

  • 8/9/2019 TA 200 Quick Start R4

    3/12

    C

    Match the holes in the mounting ears tothe tapped holes in the relay rack.Attach theshelf to

    the rack. Be sure to mount the equipment so that it

    matches the mounting space boundaries

    on the rack. All 4 holes must line up.

    Use #12-24 screws.

    D

    Install the airbaffle(s)

    (Optional).

    Install air baffles if

    airflow would

    otherwise berestricted.

    The baffle mountingears may already be attached.

    For offset mounting reverse the ears.

    The tray of the baffle must be slanted up towards the rear.

    Match the holes in the air baffle with the tapped holes in the relay rack directlybelow the installed shelf.

    Use #12-24 screws.

    Note: An air baffle may not be required if there is appropriate vent space.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    4/12

    E

    Note that the TransAccess 200 may be

    shipped with two or more RedundancyInterface Modules (RIMs) already

    installed.

    Install the

    RedundancyInterface

    Module(s)(RIMs).

    Install RIMs in the appropriate slots on

    the back of the TransAccess 200 shelf.

    One OUT RIM and one IN RIM arerequired per Service Module pair. Note

    the keying feature.

    Firmly insert the RIM into the shelf until it is fully engaged. Secure each RIM with

    the screws provided.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    5/12

    Step 2

    Install Office Wiring

    A

    Connect OfficeBattery.

    Connect "A" and/or "B" -48V to J33 on therear of the TransAccess 200 shelf. (Refer to

    Section 2.5 in the Operations Manual for pinouts.

    Connect corresponding ground connections to

    J33 also.

    Use up to 12 gauge wire (14 gauge

    recommended).

    Do not turn the power on.

    B

    Connect Minor and Major alarms to J32 on the

    rear of the TransAccess 200 shelf.Connect Office

    Alarms.

    Use up to 18 gauge wire.

    Common, Normally-open, and Normally-

    closed contacts are provided.

    See Section 2.5 of the Operations Manual for

    more details.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    6/12

    C

    Connect T1/E1 connections using

    Turin Networks PM13/PM13E

    IN/OUT cables (part number 815-00064-XXX).

    ConnectPM13/PM13E

    Module facilitiesto the RIMs.

    Connect T3/STS-1/AU3 connections

    using Turin Networks coax cableassembly (part number 815-00033-

    XXX).

    D

    Connect OMX3Module tofacilities or

    PM13/PM13E.

    Connect T3/STS1/AU3

    connections using Turin

    Networks Coax Cableassembly (part number

    815-00082-XXX).

    Note: Installing aTerminal RIM Set (part

    numbers 820-00082-001, 810-00072-001/002, 810-00073-001) eliminates the need

    for external coaxial cable connections to the PM13/PM13E Modules.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    7/12

    Step 3

    Install Modules

    A

    Install MPUModules.

    Install one or two (for redundancyoperation) MPU Modules into the left-

    most slots of the TransAccess 200 shelf.

    Each module must fully engage with theconnector in the backplane. Tighten the

    thumbscrew on the front of the MPU

    Module.

    Note: Modules may be pre-installed in the

    TransAccess 200 at the factory.

    B

    Install up to 14 Service Modules into the

    slots adjacent to the MPU Modules.Install Service

    Modules.

    The Service Modules must be installed inthe appropriate slots to match the

    Redundancy Interface Modules

    configurations at the rear.

    Each module must fully engage with the

    connector in the backplane. Tighten thethumbscrew on the front of each module.

    Note: Modules may be pre-installed in the TransAccess 200 shelf at the factory.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    8/12

    C

    ConnectOpticalCables

    Connect two optical cables

    to each OMX3 Module.Be very gentle whensliding in the connectors.

    Note: Eye Protection isrecommended in areas

    near fiber optic equipment.

    To avoid possible eye damage, connect the fiber cables to the OMX3 modules prior

    to inserting them into the shelf. Do not remove optical cables while the OMX3module is plugged into the shelf.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    9/12

    Step 4

    Power-up & Initialize the shelf

    A

    Power-up theTransAccess

    200 shelf.

    Turn on "A" and/or "B" Battery by

    throwing the appropriate switch or

    inserting the appropriate fuse at the

    Distribution Fuse Panel.

    After the MPU status LED turnsgreen, momentarily (less than 1

    second) press the Lamp Test button on

    either MPU Module. The LED on

    each module in the shelf should illuminate.

    RTN

    B

    Connect theUser InterfaceDevice (UID).

    Connect the User Interface

    Device (UID) (customer-supplied PC or Terminal) to the

    User System Interface (USI) port

    on the MPU Module.

    Note: the UID may be connected

    to either MPU Module.

    Use Turin Networks cable 815-

    00011-XXX.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    10/12

    C

    Launch theterminalprogram on

    the UID.

    Start a VT100 terminal program.(Settings are VT100 emulation,

    Data Bits = 8, Parity = none, Stop

    Bit = 1, Flow Control = none, BaudRate = 1200 up to 115,200)

    Press "Enter" twice to initiate

    communications with theTransAccess 200.

    Enter the password at the Login prompt (default is "admin" to login).

    ____________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

    D

    Select "System" at the top-levelmenu.

    "Discover"the node

    configuration. Select "Discover" in the drop-down

    menu.

    Type "y" to confirm your choice

    and press "Enter".

    E

    Select "MPU" at the top-level

    menu..

    Select "IP/SNMP Config" in the

    drop-down menu.

    Set the IP

    Address andgateway for

    Telnet/SNMPO eration

    Move the cursor to the IP and

    Gateway locations and enter the

    address. ^S to save.

    ________________

  • 8/9/2019 TA 200 Quick Start R4

    11/12

    F

    .Configurethe moduleoptions.

    From the Main Menu, select "Service Module", then "PM13/PM13E" or "OMX3".

    Under "PM13/PM13E" for example, select "Configuration" and "Line".

    Configure the "Line" settings as required. Change the default template to alter the

    default configuration.

    Press the "Tab" key to

    switch to the Dropconfiguration.

    An LBO setting of "0" takes a T1 out of service. All 28 T1's are disabled by default.

    Note: Defaultconfiguration settings areloaded when the

    TransAccess 200 is

    initially powered up. Youonly need to change those

    configuration parameters

    that will not remain at the

    default settings.

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

  • 8/9/2019 TA 200 Quick Start R4

    12/12

    ____________________________________________________________________________________________________________________________

    08/03/04 Rev. 4 940-00008-002

    G

    Connect appropriate test set(s) to the OC3/STM-1,T3/STS-1/AU3, and T1/E1 facilities connections.Verify integrityof the circuits.

    Verify error-free transmission through eachTransAccess 200 service module.

    If errors occur, check the configuration

    (especially LBO settings) and retest.