table of contents department of public...
TRANSCRIPT
8.54
6.02
1.701.50
2.78
20.87
2.24
T R A I N I N G H A L L 0 2T R A I N I N G H A L L 0 1
STO.KITCHEN
A U D I OR O O M
MO
VA
BL
E
PA
RT
IT
IO
N
S T A I R W A Y MAIN ENTRY
P O R C H R A M PR A M P
W A L K W A Y W A L K W A Y
C A N O P Y L I N E
C A N O P Y L I N EC A N O P Y L I N E
C A N O P Y L I N E
C A N O P Y L I N E
CA
NO
PY
LIN
E
CA
NO
PY
LIN
E
CA
NO
PY
LIN
E
O F F I C EA R E A
INFORMATIONDESK
WAIT ING AREA
H A L L W A Y
TOILET AREA(MALE)
PRO
JEC
TOR
SCRE
EN
PRO
JEC
TOR
SCRE
EN
UP L O U N G E
TOILET AREA(FEMALE)
G U A R DH O U S E
CO
VE
RE
D
WA
LK
WA
Y
PE
RI
ME
TE
R
FE
NC
E
DR
IV
E
WA
Y
P E R I M E T E R F E N C E
M A I N R O A D
M A I N E N T R Y
REPUBLIC OF THE PHILIPPINESDEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
DISTRICT/CITY/MUNICIPALITY
LAND USE AND ZONING
LINE AND GRADE
ARCHITECTURAL
STRUCTURAL
SANITARY/PLUMBING
ELECTRICAL
MECHANICAL
THE SITE
VICINITY MAP
N O T D R A W N T O S C A L EA
N
SITE DEVELOPMENT PLAN
A
SCALE: 1:150mts.
TABLE OF CONTENTS
SHT. NO. CONTENTS
A R C H I T E C T U R A L
PERSPECTIVE
N O T D R A W N T O S C A L E
A
VICINITY MAPSITE DEVELOPMENT PLANPERSPECTIVE
A1
GROUND FLOOR PLANREFLECTED CEILING PLAN
S T R U C T U R A L
E L E C T R I C A L
N O T H I N G F O L L O W S
A2 FRONT, & REAR ELEVATION
A3ROOF DECK PLANRIGHT & LEFT-SIDE ELEVATIONS
CROSS SECTIONSCHEDULE OF DOORS & WINDOWS
LONGITUDINAL SECTION
S1FOUNDATION PLANDECK FRAMING PLAN
TYP. 2-WAY SLAB DETAIL
TYP. RAMP DETAILSTIFFENER-MASONRY CONNECTION DETAIL
E1
TYP. CEILING DETAIL
S2
STAIRWAY DETAILSPOT DETAILSCHEDULE OF BEAMS, COLUMNS, & FOOTINGS
P L U M B I N G
P1 WASTE DISPOSAL PLUMBING LAYOUTSWATER SUPPLY PLUMBING LAYOUTS
LIGHTING OUTLET LAYOUTCONVENIENCE OUTLET LAYOUT
GENERAL NOTES
ELECTRICAL LOAD SCHEDULEPANEL BOARD DIAGRAM
ELECTRICAL SYMBOLS
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:
DATE:
PTR NO: 7563565
A R C H I T E C T
SHEET CONTENT:PROJECT TITLE:APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
A
1
1
10
Ar. ANDREW JETHRO A. TUMABIENE,uap
PRC NO: 0034472
DATE: 07-18-18
TIN NO: 472-435-260
PERSPECTIVE
SITE DEVELOPMENT PLAN
VICINITY MAP
T
OWNER:
TUMABIENE DESIGN | ARCHITECTURE" D E S I G N I N G D U R A B I L I T Y I N A E S T H E T I C "
TEMPORARY PENTHOUSE DETAILBLOW-UP TOILET DETAIL (MALE)A4LAVATORY COUNTER DETAILBLOW-UP TOILET DETAIL (FEMALE)
TYP. RAILING DETAILWF-01 DETAIL
TYP. COLUMN DETAIL
TYP. BEAM DETAILCONC. CANOPY DETAIL
P2WASTE DISPOSAL ISOMETRIC VIEW
CATCH BASIN DETAILSEPTIC VAULT DETAIL
P3WATER SUPPLY ISOMETRIC VIEW
MATERIAL SPECIFICATIONS
GENERAL NOTESLEGEND
REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
A B' C' D EB C
4.45
0.45
4.00
0.20
1.80
0.50
1.50
0.70
NATURAL GRADE LINE0
450FIN. FLOOR LINE
4450ROOF DECK LINE
0.80
4.20
3.00
1.20
P O R C H( E L E V . ±0 . 4 0 m )
R O O F D E C K A R E A
PLASTER FINISH w/ HOR. GROOVESspaced @ 0.30m STAGGERED
STONE CLADDING WALL FINISH
TEMPORARY PENTHOUSE FORSTAIRWAY
ROOF DECK SLAB MIXED w/WATERPROOFING COMPOUND
CONCRETE CANOPY 01 RECESSED PLASTER FINISH w/ HOR.GROOVES spaced @ 0.30mSTAGGERED
CONC. CANOPY
7050APEX LINE
F F
2.60
B AL C ON Y L I N E
C A N O P Y L I N EC A N O P Y L I N E
BALC
ON
Y L
INE
CA
NO
PY
LIN
E
BALC
ON
Y L
INE
LEGEND:
CL-01- DROP CEILING 70cm SUSPENDED FROM BOT. OF SLAB w/ 14" THK. MARINE PLYWOOD ON A 2" X 2" CEILING JOIST spaced@ 40cm O.C BOTH WAYS & 2" WD. CORNICE ALL AROUND.
CL-02- DROP CEILING 90cm SUSPENDED FROM BOT. OF SLAB w/ 14" THK. MARINE PLYWOOD ON A 2" X 2" CEILING JOIST spaced@ 40cm O.C BOTH WAYS & 2" WD. CORNICE ALL AROUND.
CL-03- DROP CEILING, ALIGNED TO BEAM w/ 14" THK. MARINE PLYWOOD ON A 2" X 2" CEILING JOIST spaced @ 40cm O.C BOTHWAYS & 2" WD. CORNICE ALL AROUND.
CL-04- FLAT CEILING - PLASTERED BOT. OF SLAB FINISH.
PL
PL PL PL
PLPL PL
PLPL
DLDL
DL
DL
DL DL
DL DL
C A N O P Y L I N E
C A N O P Y L I N EC A N O P Y L I N E C A N O P Y L I N E
CA
NO
PY
LIN
E
17.675.06 3.77 3.72 5.11
3.58 1.49 1.78 3.34
13.30
6.75
6.55
1.48
2.85
2.23
13.00
6.75
6.25
1.98
1.35
2.92
17.673.30 4.42 4.84 5.11
2.58 2.53
A B' C' D EB C
1
2
3
CL-03
CL-03
CL-01
CL-01
CL-03
CL-01
CL-02CL-02
CL-02 CL-02
CL-02
CL-04
CL-04
S T A I R W A Y
CM CM CM CM
CM CM
CM
1.50 1.8
0
2.40
2.40
CL-01 CL-01 CL-01
CL-01 CL-01 CL-01 CL-01
CL-03
CL-03
CL-04
CL-04
SECCROSS
SECLONG
PLAN
SECTION
0.40
0.40
0.400.40
*VAR
IES
TOP OF SLAB/BEAM
BOT. OF CEILING
CONC. SLAB
2"x2" HANGER2"x2" CEILING JOISTspaced @ 40cm O.Cboth ways
14" thick MARINE PLYWOOD w/2" WD CORNICE ALL AROUND
2"x2" CEILING JOISTspaced @ 40cm O.Cboth ways
4.45
0.45
4.00
0.60
3.40
6.001.50 0.80
6.001.50
0.50
AB'C'DE BC
NATURAL GRADE LINE0
450FIN. FLOOR LINE
4450ROOF DECK LINER O O F D E C K A R E A
STONE CLADDING WALL FINISH
ROOF DECK SLAB MIXED w/WATERPROOFING COMPOUND
P L A N T B O X P L A N T B O X
TEMPORARY PENTHOUSE FORSTAIRWAY
7050APEX LINE
2.60
T R A I N I N G H A L L 0 2T R A I N I N G H A L L 0 1
STO.KITCHEN
A U D I OR O O M
MO
VA
BL
E
PA
RT
IT
IO
N
S T A I R W A Y MAIN ENTRY
P O R C H R A M P
P L A N T B O X
R A M P
P L A N T B O X P L A N T B O X P L A N T B O XP L A N T B O X
W A L K W A Y W A L K W A Y
1.50
1.50
C A N O P Y L I N E
C A N O P Y L I N EC A N O P Y L I N E
C A N O P Y L I N E
C A N O P Y L I N E
CA
NO
PY
LIN
E
1.20
2.40
CA
NO
PY
LIN
E
CA
NO
PY
LIN
E
O F F I C EA R E A
INFORMATIONDESK
WAIT ING AREA
H A L L W A Y
TOILET AREA(MALE)
TOILET AREA(FEMALE)
PRO
JEC
TOR
SCRE
EN
PRO
JEC
TOR
SCRE
EN
1.50
UP
17.675.06 3.77 3.72 5.11
L O U N G E
3.58 1.49 1.78 3.34
13.30
6.75
6.55
1.48
2.85
2.23
13.00
6.75
6.25
1.98
1.35
2.92
1.20
17.673.30 4.20 5.06 5.11
2.58 2.53
A B' C' D EB C
1
2
3
60x60cm FLOOR TILESGLAZED (WHITE)
60x60cm FLOOR TILESGLAZED (WHITE)
60x60cm FLOOR TILESGLAZED (WHITE)
60x60cm FLOOR TILESTEXTURED
SECCROSS
SECLONG
1.20
0.801.5
0
60x60cm FLOOR TILESTEXTURED
SEE RAMP RAILINGDETAILS
ACCORDION TYPEMOVABLE PARTITION(SOUND PROOF)
40x40cm FLOOR TILESSEMI-GLAZED
SEE STAIR RAILINGDETAILS
2.22
0.72
1.50
2.521.8
00.7
2
3.00
GROUND FLOOR PLAN
SCALE:A
1:100mts.
A
2
2
10
GROUND FLOOR PLAN
REFLECTED CEILING PLAN
FRONT ELEVATION
REAR ELEVATION
TYP. CEILING DETAIL
REFLECTED CEILING PLAN
SCALE:A
1:100mts.
F R O N T E L E V A T I O N
SCALE:A
1:100mts.
R E A R E L E V A T I O N
SCALE:A
1:100mts.
G R O U N D F L O O R
TYP. CEILING DETAIL
SCALE:A
1:20mts.
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:
DATE:
PTR NO: 7563565
A R C H I T E C T
SHEET CONTENT:PROJECT TITLE:APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
Ar. ANDREW JETHRO A. TUMABIENE,uap
PRC NO: 0034472
DATE: 07-18-18
TIN NO: 472-435-260
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
F F
F FF F
DOOR 01
TYPE
QTY LOC
2.50m x 3.60m ALUMINUM FRAMEDOUBLE GLASS DOOR with FIXEDGLASS1-SET(S)REFER TO PLANS & ELEVATIONS
FIN. FLR. LINE
2.50
0.40
2.10
0.20
1.90
0.40
1.500.70 0.70
2.103.60
DOOR 03
TYPE
QTY LOC
2.10m x 0.90m ALUMINUM FRAMEGLASS DOOR3-SET(S)
FIN. FLR. LINE
2.10
0.900.80
REFER TO PLANS & ELEVATIONS
DOOR 04
TYPE
QTY LOC
2.10m x 0.80m ALUMINUM FRAMEGLASS DOOR3-SET(S)
2.10
0.800.70
REFER TO PLANS & ELEVATIONS
FIN. FLR. LINE
DOOR 05
TYPE
QTY LOC
2.10m x 0.70m PANEL DOOR w/ACCESSORIES3-SET(S)
FIN. FLR. LINE
2.10
0.800.70
REFER TO PLANS & ELEVATIONS
DOOR 06
TYPE QTY LOC
1.55m x 0.60m FLUSH DOOR2-SET(S)
FIN. FLR. LINE
0.20
0.700.60
1.75 1.5
5
REFER TO PLANS & ELEVATIONS
DOOR 02
TYPE
QTY LOC
2.10m x 1.50m DOUBLE FLUSH 1/4LITE DOOR w/ ACCESSORIES2-SET(S)REFER TO PLAN
FIN. FLR. LINE
2.10
1.500.70 0.70
WINDOW 01
TYPE
QTY LOC
1.60m x 3.00m ALUMINUM FRAMESLIDING WINDOW w/ FIXED GLASS1-SET(S)
FIN. FLR. LINE
F F F F F
WINDOW 02
TYPE
QTY LOC
1.60m x 2.40m ALUMINUM FRAMESLIDING WINDOW w/ FIXED GLASS
FIN. FLR. LINE
F F F F
2.50
0.90
1.20
3.00EQ
0.40
EQ EQEQEQ
2.50
0.90
1.20
2.40EQ
0.40
EQ EQEQ
REFER TO PLANS & ELEVATIONS REFER TO PLANS & ELEVATIONS4-SET(S)
WINDOW 03
TYPE
QTY LOC
1.60m x 1.80m ALUMINUM FRAMEAWNING WINDOW w/ FIXED GLASS
STAIR LANDING FLR. LINE
REFER TO PLANS & ELEVATIONS1-SET(S)
1.80
0.20
1.20
0.40
1.80EQ EQ
2.10
0.90
1.200.60 0.60
WINDOW 04
TYPE
QTY LOC
1.20m x 1.20m ALUMINUM FRAMESLIDING WINDOW
FIN. FLR. LINE
1.20
REFER TO PLANS & ELEVATIONS1-SET(S)
2.10
0.90
1.200.60 0.60
WINDOW 05
TYPE
QTY LOC
1.20m x 1.20m ALUMINUM FRAMEFIXED GLASS WINDOW
FIN. FLR. LINE
1.20
REFER TO PLANS & ELEVATIONS1-SET(S)
F
WINDOW 06
TYPE
QTY LOC
2-SET(S)
FIN. FLR. LINE
0.40m x 1.20m ALUMINUM FRAMEAWNING WINDOW
2.10
1.70
1.200.60 0.60
0.40
REFER TO PLANS & ELEVATIONS
F F
4.45
0.45
4.00
0.60
3.40
CL-01CL-02CL-03
TRAINING HALL O1(ELEV. ±0.45m)
AUDIORO O MSTORAGE
STAIRLANDING(ELEV. ±2.00m)
CL-04 CL-04
P O R C H( E L E V . ± 0 . 4 0 m )
ROOF DECK SLAB w/ 3-COATS OFMULTI-HIGH QUALITY WATERPROOFINGR O O F D E C K A R E A
(ELEV. ±4.45m)
1 2 3
4.45
0.45
4.00
0.60
3.40
NATURAL GRADE LINE0
450FIN. FLOOR LINE
4450ROOF DECK LINE
4" WD CONCRETE ZOCALLOWALL AROUND STAIRWELL RIM
0.10
SEE TYP.RAILING DETAIL
7050APEX LINE
2.60
4.45
0.45
4.00
0.50
3.50
1 2 3
P O R C H( E L E V . ± 0 . 4 0 m )
R O O F D E C K A R E A
NATURAL GRADE LINE0
450FIN. FLOOR LINE
4450ROOF DECK LINE
STONE CLADDING WALL FINISH
1"GROOVE
TEMPORARY PENTHOUSE FORSTAIRWAY
7050APEX LINE
2.60
A B' C' D EROOF DECK SLAB w/ 3-COATS OFMULTI-HIGH QUALITY WATERPROOFING
TRAINING HALL O1(ELEV. ±0.45m)
TRAINING HALL O2(ELEV. ±0.45m)
R O O F D E C K A R E A(ELEV. ±4.40m) (ELEV. ±4.45m)
4.45
0.45
4.00
0.60
NATURAL GRADE LINE0
450FIN. FLOOR LINE
4450ROOF DECK LINE
3.40
CL-01 CL-01 CL-01 CL-01
CEILING LINE
3.20
(ELEV. ±0.20m)
CL-04
ACCORDION TYPEMOVABLE PARTITION(SOUND PROOF)
CEILING LINE
123
4.45
0.45
4.00
0.60
3.40
NATURAL GRADE LINE0
450FIN. FLOOR LINE
4450ROOF DECK LINE
P O R C H( E L E V . ± 0 . 4 0 m )
PLASTER FINISH w/ HOR. GROOVESspaced @ 0.30m STAGGERED
STONE CLADDING WALL FINISH
R O O F D E C K A R E A
ROOF DECK SLAB MIXED w/WATERPROOFING COMPOUND
TEMPORARY PENTHOUSE FORSTAIRWAY
CONC. CANOPY
7050APEX LINE
2.60
2% SLOPE(MAINTAIN)
2% SLOPE(MAINTAIN)
R O O F D E C K A R E A
TEMPORARYPENTHOUSE FORSTAIRWAY
C A N O P Y L I N E
C A N O P Y L I N E
C A N O P Y L I N E
C A N O P Y L I N E
C A N O P Y L I N E
C A N O P Y L I N EC A N O P Y L I N E C A N O P Y L I N E
CA
NO
PY
LIN
E
CA
NO
PY
LIN
E
CA
NO
PY
LIN
E
SECCROSS
SECLONG
2% SLOPE(MAINTAIN)
2% SLOPE(MAINTAIN)
2% SLOPE(MAINTAIN)
2% SLOPE(MAINTAIN)
2% SLOPE(MAINTAIN)
2% SLOPE(MAINTAIN)
B A LC O N Y L I N E
BALC
ON
Y L
INE
BALC
ON
Y L
INE
ROOF DECK SLAB w/ 3-COATS OFMULTI-HIGH QUALITY WATERPROOFING
2% S
LOPE
(MAI
NTAI
N)
2% S
LOPE
(MAI
NTAI
N)
17.675.06 3.77 3.72 5.11
3.58 1.49 1.78 3.34
13.30
6.75
6.55
1.48
2.85
2.23
13.00
6.75
6.25
1.98
1.35
2.92
17.673.30 4.42 4.84 5.11
2.58 2.53
A B' C' D EB C
1
2
3
1.50 1.8
0
2.40
2.40
SCHEDULE OF DOORS & WINDOWS
SCALE:A
1:50mts.
RIGHT-SIDE ELEVATION
SCALE:A
1:100mts.
C R O S S S E C T I O N
SCALE:A
1:100mts.
LONGITUDINAL SECTION
SCALE:A
6 6 1:100mts.
A
3
3
10
ROOF DECK PLAN
RIGHT-SIDE ELEVATION
LEFT-SIDE ELEVATION
SCHEDULE OF DOORS & WINDOWS
CROSS SECTION
LONGITUDINAL SECTION
R O O F D E C K P L A N
SCALE:A
1:100mts.
LEFT-SIDE ELEVATION
SCALE:A
1:100mts.
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:
DATE:
PTR NO: 7563565
A R C H I T E C T
SHEET CONTENT:PROJECT TITLE:APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
Ar. ANDREW JETHRO A. TUMABIENE,uap
PRC NO: 0034472
DATE: 07-18-18
TIN NO: 472-435-260
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
0.80
0.10
0.60
0.10
0.05
0.55
0.600.08
0.15 0.30
0.080.45
4" GRANITE TILES (GLAZED)BACK SPLASH
STAINLESS STEEL FAUCET
STAINLESS STEEL DRAIN
60x60cm GRANITE TILESCOUNTER
3"THK COUNTER SLAB w/10mmØ RSB spaced @ 0.20mO.C. both ways & WATERPROOFING COMPOUND
STAINLESS STEEL CABINETHANDLE
2"Ø PVC DRAINAGE PIPE2"Ø PVC P-TRAP
60x60cm TILES
0.08
3" DEPTH TOE KICK
FINISH FLOOR LINE
S E C T I O N
0.90
0.10
0.80
0.10
0.60
0.10
0.05
0.55
*VARIES
0.14
0.55
0.45
0.60
FINISH FLOOR LINE
E L E V A T I O N
4" GRANITE TILES (GLAZED)BACK SPLASH
STAINLESS STEEL FAUCET
60x60cm GRANITE TILESCOUNTER
L A V A T O R Y
CA
BI
NE
T
L A V A T O R Y
C A B I N E T S
T O E K I C K B O A R D
2 - 45x50cm CABINET DOORw/ COMPLETE ACCESSORIES
34"THK MARINE PLYWOOD
0.10
L/2 L/2
WATER CLOSET
8"x16"x4" CHB w/ 1" PLASTER BOTH SIDES
8"x1
6"x4
" CHB
w/ 1
" PLA
STER
BOT
H SI
DES
8"x1
6"x4
" CHB
w/ 1
" PLA
STER
BOT
H SI
DES
PA
RT
OF
HR
OF
FIC
E A
RE
A
3-LA
YERS
OF
40x4
0cm
VITR
IFIE
DW
ALL T
ILES
SEMI
GLA
ZED
LAVATORY
PA
RT
OF
TO
ILE
T (
FE
MA
LE
)
P A R T O F H A L L W A Y
40x40cm FLOOR TILESSEMI-GLAZED
COLUMN
SEE COUNTER DETAIL
0.15
0.60
0.51
0.51
1.02
0.35
0.38
0.60
0.48
0.48
0.20
0.801.51 0.232.53
2.60
0.84
1.76
TOILET (MALE)ELEV: 1" LOWER FROM FINISH
FLOOR LINE
2"THK CONCRETE WALL w/10mmØ RSB spaced @ 0.20mO . C . b o t h w a y s & 1 " T H KP L A S T E R B O T H S I D E S
2.380.55 1.20 0.63
0.70
0.08
0.25
1.20
0.70
FLR.DRAIN
FLR.DRAIN
WATER CLOSET
8"x16"x4" CHB w/ 1" PLASTER BOTH SIDES
8"x1
6"x4
" CHB
w/ 1
" PLA
STER
BOT
H SI
DES
8"x1
6"x4
" CHB
w/ 1
" PLA
STER
BOT
H SI
DES
3-LA
YERS
OF
40x4
0cm
VITR
IFIE
DW
ALL T
ILES
SEMI
GLA
ZED
LAVATORY
PA
RT
O
F
TO
IL
ET
(
MA
LE
)
P A R T O F H A L L W A Y
40x40cm FLOOR TILESSEMI-GLAZED
COLUMN
SEE COUNTER DETAIL
0.15
0.60
0.51
0.51
1.02
0.35
0.38
0.60
0.48
0.48
0.20
0.801.51
0.232.53
2.60
0.84
1.76
TOILET (FEMALE)ELEV: 1" LOWER FROM FINISH
FLOOR LINE
2"THK CONCRETE WALL w/10mmØ RSB spaced @ 0.20mO . C . b o t h w a y s & 1 " T H KP L A S T E R B O T H S I D E S
2.130.551.200.63
0.70
0.08
0.25
1.20
0.70
FLR.DRAIN
FLR.DRAIN
3.78
4.25
1.490.40
3.45
TR
US
S
1.49 0.40
0.40
0.40
TR
US
S
TR
US
S
2"x3" PURLINS (goodl u m b e r ) s p a c e d @0 . 6 0 M s t a g g e r e d
2 " x 3 " F L Y I N G R A F T E R( g o o d l u m b e r )
R O O F L I N E
RO
OF
L
IN
E
RO
OF
L
IN
E
R O O F L I N E
1.80
1.20
0.60
2.60
0.60 0.70
0 . 7 0 x 1 . 8 0 mFLUSH DOOR
0.60mx1.20m JALOUSIEW I N D O W w / B A R S
ROOF DECK LINE4450
7050APEX LINE
4"CONC. ZOCALLO WALL
3.78
4.25
1.72
R O O F L I N E
RO
OF
L
IN
E
0.40
0.40
S L O P E
S L O P E
1.72
3.78
C O R R U G A T E DG . I . S H E E T G A # 2 6
G A # 2 4 G . I S H E E TR I D G E C A P
1/2"
thk
x 20
cm F
IBER
CE
ME
NT
BO
AR
D
RO
OF
L
IN
E
R O O F L I N E
2.98
3.45
1.041.290.65
3.45
R O O F L I N E
RO
OF
L
IN
E
RO
OF
L
IN
E
R O O F L I N E
2"x3" (good lumber) STUDS& GIRT S spaced @ 0.60mst a g ge r e d w / 1
4 " F I B E RCEMENT BOARD SIDINGo n b o t h s i d e s .
2.60
2.10
0.50
ROOF DECK LINE4450
7050APEX LINE
2"x3" (good lumber) STUDS& GIRTS spaced @ 0.60ms t ag g e r e d w / 1
4 " F I B E RCEMENT BOARD SIDINGo n b o t h s i d e s .
4"CONC. ZOCALLO WALL
A
4
4
10
TEMPORARY PENTHOUSE DETAIL
BLOW-UP TOILET DETAIL (MALE)
BLOW-UP TOILET DETAIL (FEMALE)
LAVATORY COUNTER DETAIL
TEMPORARY PENTHOUSE DETAIL
SCALE:A
1:50mts.
P L A N R O O F P L A N
S I D E E L E V A T I O N
F RO N T EL E VA T I O N
ROOF FRAMING PLAN
BLOW-UP TOILET DETAIL (MALE)
SCALE:A
1:20mts.
BLOW-UP TOILET DETAIL (FEMALE)
SCALE:A
1:20mts.
L A V A T O R Y C O U N T E R D E T A I L
SCALE:A
1:50mts.
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:
DATE:
PTR NO: 7563565
A R C H I T E C T
SHEET CONTENT:PROJECT TITLE:APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
Ar. ANDREW JETHRO A. TUMABIENE,uap
PRC NO: 0034472
DATE: 07-18-18
TIN NO: 472-435-260
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
ELEV.=0.45M ELEV.=0.45M
ELEV.=0.45M
ELEV.=0.45M
ELEV.=0.40M
ELEV.=0.40M
ELEV.=0.45M
ELEV.=0.45MELEV.=0.45M
ELEV.=0.425M ELEV.=0.425M
ELEV.=0.40MELEV.=0.40M
ELEV.=0.45M
R A M P
P L A N T B O X
R A M P
P L A N T B O X
ELEV.=0.20M ELEV.=0.20M ELEV.=0.20M
C1F1
C1F1
C1F1
C1F1 C1F1 C1F1C1F1C1F1
C1F1
C1F1 C1F1 C1F1 C1F1
TB-01 TB-01 TB-01 TB-01
TB-01TB-01TB-01
TB-01 TB-01 TB-01 TB-01
TB-01TB
-01 TB
-01
TB-0
1
TB-0
1
TB-0
1
TB-0
1
WF-01 WF-01
WF-01WF-01
WF-01
WF-01 WF-01
WF-
01
WF-
01
WF-
01
WF-
01WF-
01
WF-
01
WF-
01
WF-
01
WF-
01
0.125m THK. CONC. SLAB w/10mmØ RSB spaced @0.30m BOTHWAYS
STIFFENER COLUMN
STIFFENER COLUMN
C2F2 C2F2
P L A N T B O X P L A N T B O X
P L A N T B O X
17.675.06 3.77 3.72 5.11
3.58 1.49 1.78 3.34
13.30
6.75
6.55
1.47
1.65
2.23
13.00
6.75
6.25
1.98
1.35
2.92
17.673.30 4.42 4.84 5.11
2.58 2.53
A B' C' D EB C
1
2
3
1.50
2.22
0.72
1.50
2.521.8
00.7
2
3.00
1.20
1.501.50
WF-01
WF-
01 WF-
01
NOTE:- USE GRADE 40 FOR 10mmØ RSB & below.- USE GRADE 50 FOR 12mmØ RSB & above.
ELEV.=4.45M
ELEV.=4.40M
ELEV
.=4.4
0MEL
EV.=
4.40M
ELEV.=4.40M
B AL C ON Y L I N E
C A N O P Y L I N EC A N O P Y L I N E
BALC
ON
Y L
INE
CA
NO
PY
LIN
E
BALC
ON
Y L
INE
C A N O P Y L I N EC A N O P Y L I N E C A N O P Y L I N E
CA
NO
PY
LIN
E
S T A I R W E L L
CA
NO
PY
LIN
E
C A N O P Y L I N E
C A N O P Y L I N E C A N O P Y L I N E
STIFFENER
STIFFENER
NOTE:- PROVIDE 1.00m LENGTH RSB DOWELS
AT COLUMNS, STIFFENERS, STAIRS &WALLS FOR PHASE-II UTILIZATION.
- PROVIDE 4"x4" CONC. ZOCALLO AROUNDTHE RIM OF STAIRWELL OPENINGMONOLITHIC w/ CONCRETE SLAB.
ROOF DECK SLAB w/ 3-COATS OFMULTI-HIGH QUALITY WATERPROOFING
0.20
0.60 0.3
0
0.80
0.80
0.30 0.8
0
0.30
0.30
0.80
17.675.06 3.77 3.72 5.11
2.63 2.44 2.59 2.52
13.30
6.78
6.52
1.45
1.57
3.50
13.00
6.78
6.22
2.05
1.78
4.45
17.673.30 4.40 4.86 5.11
2.58 2.53
A B' C' D EB C
1
2
3
2.40
1.48 2.30 1.27 2.46
1.28
1.35
1.35
0.18
2.62
1.27 3.60
4.72
FB-01 FB-01 FB-01 FB-01
FB-01 FB-01 FB-01 FB-01
FB-01 FB-01 FB-01
FB-0
1FB
-01
FB-0
1
FB-02
FB-02
FB-02
FB-0
2FB
-02
FB-02
CB-0
2
CB-0
2CB
-01
CB-0
1
CB-02
CB-02
CB-02
CB-02
FB-0
1
FB-0
1FB
-01
FB-0
1FB
-01
FB-0
1FB
-01
FB-0
1
FB-0
1FB
-01
FB-0
1FB
-01
FB-0
1FB
-01
FB-0
1FB
-01
FB-02 FB-02 FB-02
FB-02 FB-02 FB-02 FB-02
NOTE:- USE GRADE 40 FOR 10mmØ RSB & below.- USE GRADE 50 FOR 12mmØ RSB & above.
0.15
0.20
*VAR
IES
*VARIES
COMPACTED EARTH FILL
0.10M thk CONC. RAMP w/- 12" GROOVES spaced @ 0.10m O.C.- 10MM Ø RSB SPACED AT 0.25m O.C BOTH WAYS
0.10m thick GRAVEL BED (COMPACTED)
NGL
0.10
0.70 0.9
0
0.20
2" Ø STAINLESS STEEL RAILINGS
112" Ø STAINLESS STEEL
BALUSTER spaced @ 0.60m O.C.
40
X
B
AR
Ø
TT
PASSING THROUGH COLUMN
T
CHB REINFORCEMENT
MUST BE CONTINUOUS
PASSING THROUGH COLUMN
40 X BAR Ø
40
X
B
AR
Ø
T
T
NOTES: "T" DENOTES
T
CHB REINFORCEMENT
MUST BE CONTINUOUS
40
XB
AR
Ø
T
THICKNESS OF CHB
MUST BE CONTINUOUS
PASSING THROUGH COLUMN
CHB REINFORCEMENT
40 X BAR Ø
T
STIFFENER COLUMNS
SHALL USE Ø12mm MAIN
BARS W/ Ø10mm TIES
T T
0.30m
BEAMS SHALL BE MADE TO
ALL CHB AT EVERY 2.0m SPAN
STIFFENER COLUMNS OR
OF MASONRY VERTICALLY AND
HORIZONTALLY.
CHB REINFORCEMENT
MUST BE CONTINUOUS
PASSING THROUGH COLUMN
L/4 L/4
*VARIES (L)
L/2
12mmØ BOT. BARS spaced @0.25m O.C bothways
12mmØ BENT BARS spaced@ 0.25m M.O.C
12mmØ CUT BARS spaced @0.25m M.O.C (IN BETWEENBENT BARS)
L/4L/4
*VAR
IES
(L)
L/2
10mmØ TOP BARS spaced @0.25m O.C bothways
0.125
TOP REINFORCEMENT
BOT. REINFORCEMENT
TOP REINFORCEMENT
BOT. REINFORCEMENT
SECTION
PLAN
NOTE:- USE GRADE 40 FOR
10mmØ RSB & below.- USE GRADE 50 FOR
12mmØ RSB & above.
S
5
1
10
FOUNDATION PLAN
DECK FRAMING PLAN
TYP. RAMP DETAIL
STIFFENER-MASONRY CONNECTION
DETAIL
TYP. 2-WAY SLAB DETAIL
STIFFENER-MASONRY CONNECTION DETAIL
SCALE:S
1:25mts.
T Y P . R A M P D E T A I L
SCALE:S
1:25mts.TYP. 2-WAY SLAB DETAIL
SCALE:S
1:25mts.
F O UND AT I ON P L AN
SCALE:S
1:100mts.DECK FRAMING PLAN
SCALE:S
1:100mts.
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:SHEET CONTENT:PROJECT TITLE:
APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
PRC NO: 0140417
DATE: 02-07-18
DATE:
PTR NO: 7593901 TIN NO: 430-530-215
STRUCTURAL / CIVIL ENGINEER
Engr. JAIME C. SALAZAR Jr.
SECTION
L/4
TOP BARS
BOT. BARS
*VARIES (L)
L/4
COLUMN COLUMN
CUT BARS
@ SUPPORT @ MID SPAN
NOTE:- BEAM REINFORCEMENTS MUST BE CONTINUOUS PASSING
THROUGH COLUMN or OTHER BEAM.- USE GRADE 40 FOR 10mmØ RSB & below.- USE GRADE 50 FOR 12mmØ RSB & above.
L/5 L/5
@ SUPPORT @ MID SPAN
DIAGRAM
MAIN REINF.
C1 C2 STIFFINER
S C H E D U L E O F C O L U M N S :
COLUMN
12-20mmØ 10-20mmØ 3-12mmØ
TIES(SIZE & SPACING)
SECONDARY TIES YES YES -
S C H E D U L E O F F O O T I N G S :
FOOTING
10mmØ spaced @ 0.15m
X (mm) Y (mm) THICKNESS(mm)
DEPTH(mm)
REIN. @ X
F2 1700 3700 350 3000 19-20mmØ spaced equallyO.C.
9-20mmØ spaced equallyO.C.
REIN. @ Y REMARKS
ISOLATED FOOTING
DIAGRAM
REIN. @ SUPPORT
TB1 FB1
S C H E D U L E O F B E A M S :
BEAM
5-16mmØ
TIES(SIZE & SPACING)
10mmØ spaced @ 3-0.05m,3-0.10m, 3-0.15m, rest @
0.20m.
0.45
0.45
REIN. @ MIDSPAN
3-16mmØ2-16mmØ2-16mmØ2-16mmØ2-16mmØ
0.25
0.375
0.30
0.30
0.10
0.25
FB2
10mmØ spaced @ 2-0.05m,2-0.10m, 2-0.15m, 2-0.20m,
rest @ 0.25
10mmØ spaced @ 2-0.05m,2-0.10m, 2-0.15m, 2-0.20m,
2-0.25m, rest @ 0.30m.
10mmØ spaced @ 3-0.05m,3-0.10m, 3-0.15m, rest @
0.20m.
0.30
0.60
10mmØ spaced @ 3-0.05m,3-0.10m, rest @ 0.15m.
8-20mmØ4-20mmØ
0.30
0.70
F1 2500 2500 350 3000 12-20mmØ spaced equallyO.C.
12-20mmØ spaced equallyO.C.
ISOLATED FOOTING
8-20mmØ4-20mmØ
5-16mmØ3-16mmØ
5-16mmØ3-16mmØ
0.25
0.375
CB2CB1
5-16mmØ3-16mmØ
0.25
0.50
10mmØ spaced @ 2-0.05m,2-0.10m, 2-0.15m, rest @
0.20m.
10mmØ spaced @ 3-0.05m,3-0.10m, rest @ 0.15m.
5-16mmØ3-16mmØ
5-16mmØ3-16mmØ
X
Y
PLAN
SECTION
DEPT
H *VAR
IES
THK
COLUMN
"Y" REINFORCEMENT
REINFORCEMENT"X" & "Y"
MAIN REINFORCEMENT
NATURAL GRADE LINE
2" THK. GRAVEL BED
"X" REINFORCEMENT
TB-01
0.40
*VARIES
0.10
CONC. CANOPY w/10mmØ RSB spaced @
0.12m O.C both ways
0.05 0.20
1"thick PLASTER
0.10mX0.20m LINTEL BEAMw/ 12mmØ MAIN RSB &10mmØ HOOK [email protected]. O.C (ALTERNATE)
1" DRIP MOULD
4" thick CHB WALL
0.10
0.15
1 % S L O P E
SECTION
NOTE: CANOPYREINFORCEMENTS MUSTBE CONTINUOUS PASSINGTHROUGH BEAM/TIE-BEAM
0.05
0.12
0.125m thk CONC.SLABCLASS-A CONC. MIX w/ 10mmØ TEMP.BARS spcd @ 30cm O.C bothways
0.300.15
0.15m x 0.30m WALL FOOTINGw/ 3-12mmØ BASE BARS &10mmØ HOOK BARS spcd @30cm O.C
6" thk CHB WALLw/ 10mmØ VERTICAL BARS spcd
@ 60cm O.C & 10mmØ HOR. BARSspcd EVERY 3 LAYERS OF CHB
6" thk CHB WALLw/ 10mmØ VERTICAL BARS spcd
@ 60cm O.C & 10mmØ HOR. BARSspcd EVERY 3 LAYERS OF CHB
0.15m x 0.30m WALL FOOTINGw/ 3-12mmØ BASE BARS &10mmØ HOOK BARS spcd @30cm O.C
0.55 0.4
00.1
50.1
5
0.15M THK GRAVEL BED
0.10M THK GRAVEL BED
ELEV. *VARIES
NGL
PLAN
SECTION
*VAR
IES
0.90
0.25
0.10
0.56
0.15
0.60 0.60
2"Ø STAINLESS STEEL PIPE RAILING
112 "Ø STAINLESS STEEL PIPE BALUSTER
1"Ø STAINLESS STEEL PIPE HOR. BRACING
ELEV. *VARIES
SECTION ELEVATION
1"Ø STAINLESS STEEL PIPE HOR. BRACING
0.300.30 0.30 0.30
BOLTED w/ FLANGE (STAINLESS)
S T O R A G E A R E A
ROOF DECK SLAB w/ 3-COATSOF MU LTI -H IGH QU ALITYW A T E R P R O O F I N G
SE E T Y P . RA ILI N G DE T .
GROUND FIN. FLR. LINE450
1.90
4.00
2.00
2.00
3.90
F B - 0 1 F B - 0 1
S E E S P O T D E T A I L
44502ND FLOOR LINE
C O N C R E T EEYELASH CANOPY
P O R C H
STAIR LANDING
3850BOT OF BEAM
7050APEX LINE
2.60
2.10
0.50
2.75
1
0.20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
3.650.40 0.40L/2 L/2
1.80
L/4
1 2 m m Ø T E M P B A R Ss p c d @ 3 0 c m
12mmØ TOP & BOT BARS
1 2 m m Ø N O S I N G B A R Ss p c d a s s h o w n
1/4"thk 16"x16" CERAMICF L O O R T I L E S ( M A T T )
1 " t h k M OR T A R
4-12mmØ BEDBARS
12mmØ HOR. BARS12mmØ VERTICALB A R S
0.84
0.13
0.70
0.20
0.50
GRND. FIN. FLOOR LINE
1
2
3
4
5
100mm thk GRAVELB E D
1 0 m m Ø B E N DB A R S
0.60
0.10
NOTE:SEE TYPICAL RAILING DETAIL FORS T A I R R A I L I N G D E S I G N .EQ
0.30
EQ
EQ
0.40 1.83 1.83 0.40
4.45
0.50
G A # 2 4 G . I S H E E T R I D G E C A P
CORRUGATED G.I SHEET G.A # 26
2"x3" BOT. CHORD (good lumber)
2"x3" TOP CHORD (good lumber)
0.60
1/2" thk x 20cm FIBER CEMENT BOARD
UMBRELLA NAILS w/ GLASS SEALANT
0.60
S
6
2
10
STAIRWAY DETAIL
SPOT DETAIL
SCHEDULE OF BEAMS,COLUMNS,
& FOOTINGS
TYP. COLUMN DETAIL
CONC. CANOPY DETAIL
TYP. BEAM DETAIL
WF-01 DETAIL
TYP. RAILING DETAIL
TRUSS DETAIL
TYP. COLUMN DETAIL
SCALE:S
1:25mts.
T Y P . B E A M D E T A I L
SCALE:S
1:25mts.
CONC. CANOPY DETAIL
SCALE:S
1:10mts.
W F - 0 1 D E T A I L
SCALE:S
1:25mts.
T Y P . R A I L I N G D E T A I L
SCALE:S
1:25mts.
S T A I R W A Y D E T A I L
SCALE:S
1:50mts.
S P O T D E T A I L
SCALE:S
1:25mts.
T R U S S D E T A I L
SCALE:S
1:20mts.
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:SHEET CONTENT:PROJECT TITLE:
APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
PRC NO: 0140417
DATE: 02-07-18
DATE:
PTR NO: 7593901 TIN NO: 430-530-215
STRUCTURAL / CIVIL ENGINEER
Engr. JAIME C. SALAZAR Jr.
SV
CB
CBCBCB CBCB
CB
CBCB CB
CB
CB
CB
CB
TO MAINDRAINAGE
TO MAINDRAINAGE
TO MAINSEWER LINE
FD
FD
FD
FD
FD
COCO
CO
CO
WC WC
LAV LAV
SINK
SS
SS
SS
SS
WS
WS
WS
WS
WS WS
WS
DS
DS
DS
WSDSWS
4"Ø PVC PLUGROUGHING-IN FOR PHASE-II
4"Ø PVC PLUGROUGHING-IN FOR PHASE-II
NOTE:- USE 4"Ø S1000 PVC PIPE FOR SANITARYLINE, 3"Ø PVC S1000 PIPE FORDRAINAGE LINE, 3/4"Ø uPVC PIPE FORWATER SUPPLY LINE
- SECOND FLOOR PLUMBING LAYOUT ISFOR ROUGHING-INS ONLY.
- ALL EXPOSED ROUGH-IN PIPES MUST BESECURED OR PLUGGED UNTIL PHASE-IIUTILIZATION.
UPDOWN
FDFD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
NOTE:- USE 4"Ø S1000 PVC PIPE FOR SANITARYLINE, 3"Ø PVC S1000 PIPE FORDRAINAGE LINE, 3/4"Ø uPVC PIPE FORWATER SUPPLY LINE
- SECOND FLOOR PLUMBING LAYOUT ISFOR ROUGHING-INS ONLY.
- ALL EXPOSED ROUGH-IN PIPES MUST BESECURED OR PLUGGED UNTIL PHASE-IIUTILIZATION.
COCO
CO
CO
CO
CO
CO
WC
WC
WC
WC
WC
WC
LAV
LAV
LAV
LAV
LAV
SINK
U
SS
SS
SS
SS
WS
WS
WSWS WS
WS
WS
WS DS
WS
DSDS
DS
FD
CV
GV
WMM
NOTE:- USE 4"Ø S1000 PVC PIPE FOR SANITARYLINE, 3"Ø PVC S1000 PIPE FORDRAINAGE LINE, 3/4"Ø uPVC PIPE FORWATER SUPPLY LINE
- SECOND FLOOR PLUMBING LAYOUT ISFOR ROUGHING-INS ONLY.
- ALL EXPOSED ROUGH-IN PIPES MUST BESECURED OR PLUGGED UNTIL PHASE-IIUTILIZATION.
RISER
LAV
WC
LAV
WC
SINK
UPDOWN
NOTE:- USE 4"Ø S1000 PVC PIPE FOR SANITARYLINE, 3"Ø PVC S1000 PIPE FORDRAINAGE LINE, 3/4"Ø uPVC PIPE FORWATER SUPPLY LINE
- SECOND FLOOR PLUMBING LAYOUT ISFOR ROUGHING-INS ONLY.
- ALL EXPOSED ROUGH-IN PIPES MUST BESECURED OR PLUGGED UNTIL PHASE-IIUTILIZATION.
LAV
LAVF
SHO
FSHO
FSHO
LAV
WC
WC
WC
FSHO
WC
WC
LAV
LAV
WC
FSHO
SINK
RISER
U
P
7
1
10
WASTE DISPOSAL PLUMBING LAYOUT
(GROUND FLOOR)
WASTE DISPOSAL PLUMBING LAYOUT
(ROOF DECK)
WATER SUPPLY PLUMBING LAYOUT
(GROUND FLOOR)
WATER SUPPLY PLUMBING LAYOUT
(ROOF DECK)
WASTE DISPOSAL PLUMBING LAYOUT
SCALE:P
1:100mts.
G R O U N D F L O O RWASTE DISPOSAL PLUMBING LAYOUT
SCALE:P
1:100mts.
R O O F D E C K
WATER SUPPLY PLUMBING LAYOUT
SCALE:P
1:100mts.
G R O U N D F L O O RWATER SUPPLY PLUMBING LAYOUT
SCALE:P
1:100mts.
R O O F D E C K
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:SHEET CONTENT:PROJECT TITLE:
APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
DATE:
PTR NO:
SANITARY ENGINEER / MASTER PLUMBER
PRC NO:
DATE:
TIN NO:
SV
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
TO MAINDRAINAGE
TO MAINDRAINAGETO MAIN
SEWER LINE
FD
FD
FD
FD
FD
FD
FD
FD
FDFD
FD
FD
FD
FD
FD
FD
FD
FDFD
FD
FD
CO CO
CO
CO
COCO CO
CO
CO
CO
CO
WC
WC
WC
WC
WC
WC
WC
WC
LAV
SINK
LAV
LAV
LAV
LAV
LAV
SINK
U
SS
SS
SS
SS
SS
SS
SS
SS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
WS
DS
DS
DS
WS
DS
WS
WS
WS
WS
DS
WS
DS
DS
DS
LAV
0.50
0.30
0.10
0.10
0.500.300.10 0.10
8"x16"x4" CHB
4"Ø PVCDRAINAGE PIPE
0.50
0.10
0.30
0.10
0.10
10mmØ HANDLE
3"Ø PVCDOWNSPOUT
8"x16"x4" CHB
3-10mmØ BOT BARS
CONC. COLUMN
4"Ø DRAINAGEPVC PICE
PLAN
SECTION
MANHOLE MANHOLE
DIGESTIVE CHAMBERLEACHING CHAMBER
OUTLET INLET
4"Ø PVC OUTLET PIPE w/ CLEANOUT
4"Ø PVC TEE w/ CLEANOUT
4"Ø PVC INLET PIPE w/ CLEANOUT
P L A N
1.50
0.10
1.30
0.10
0.50
2.50M.
0.70 0.10 1.50 0.10
0.50 0.50
NGL
4"Ø PVC PIPE w/CLEANOUT &SANITARY TEE
D I G E S T I V EC H A M B E R
L E A C H I N GC H A M B E R
AIR
GAP
WATER LEVEL
4" T
HK C
HB w
/ 1" P
LAST
ERIN
G
4" T
HK C
HB w
/ 1" P
LAST
ERIN
G
4" T
HK C
HB w
/ 1" P
LAST
ERIN
G
CHB WALL w/ 10mmØVERT. BARS spaced @0.40m & 10mmØ HOR.BARS spaced @ EVERY2-LAYERS OF CHB.
0.20m THK CONC. SLABw/ 12mmØ RSB spaced@ 0.40m O.C. both ways.
0.10m THK CONC. MANHOLE w/ 6-12mmØRSB spaced @ 0.15m. O.C. both ways.
0.10m THK CONC. SLAB w/ 12mmØRSB spaced @ 0.15m. O.C. both ways.
NGL
C.O. C.O.
OUTLET
0.10
2.90
1.50 1.2
00.1
00.2
0
S E C T I O N
I S O M E T R I C V I E W
N O T D R A W N T O S C A L EP
WASTE DISPOSAL PLUMBING LAYOUT
CATCH BASIN DETAIL
P
SCALE: 1:20mts.
SEPTIC VAULT DETAIL
P
SCALE: 1:25mts.
P
8
2
10
WASTE DISPOSAL PLUMBING LAYOUT
(ISOMETRIC VIEW)
SEPTIC VAULT DETAIL
CATCH BASIN DETAIL
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:SHEET CONTENT:PROJECT TITLE:
APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
DATE:
PTR NO:
SANITARY ENGINEER / MASTER PLUMBER
PRC NO:
DATE:
TIN NO:
M
LAVATORY
FLOOR DRAIN
WATER CLOSET
CATCH BASIN
CLEAN OUT
DOWN SPOUT
SOIL STACK
WASTE STACK
STACK VENT
WASTE VENT
VENT THRU ROOF
GATE VALVE
WATER METER
WATER SUPPLY PIPE LINE
WATER WASTE PIPE LINE
SOIL PIPE LINE
VENT LINE
LEGEND:
LAV.
FD.
WC.
CB.
CO.
DS.
SS.
WS.
SV.
WV.
VTR.
WM.
CHECK VALVECV.
GV.
URINALU.
FAUCETF.
SHOWERSHO.
GENERAL NOTES:
1. ALL PLUMBING WORK INDICATED HEREIN SHALL MEET THE PROVISION OFTHE PLUMBING CODE OF THE PHILIPPINES, THE NATIONAL PLUMBING CODE, LOCAL CITY ORDINANCE RULES ANDREGULATIONS.
2. PLUMBING CONTRACTOR TO COORDINATE WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS, AND NOTIFY THECONSULTING ENGINEER OF ANY DISCREPANCY FOUND.
3. ALL PLUMBING PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATION REQUIRED FOR PROPEREXECUTION OF OTHER TRADE SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL SITECONDITION, DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS OTHERWISE SPECIFIED.
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, TAPPING POINT AND WATER LINE SERVICECONNECTING POINT UNLESS OTHERWISE SPECIFIED.
8. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED.
9. ALL PIPE SIZE AND DIMENSION ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.
MATERIAL SPECIFICATIONS:
SOLID WASTE PIPE SHALL BE 4" DIA POLYVINYL (PVC) PIPE, SERIES 1000 OR APPROVED EQUAL FITTING SHALL BE PVC WITH SOLVENT CEMENT JOINT TO ASTM D2564
WATER WASTE PIPE SHALL BE 3" DIA PVC PIPE (MAIN LINE) FLOOR DRAIN 3" DIA PVC (BRANCHING) LAVATORY 2" DIA PVC (BRANCHING) SINK 2" DIA PVC (BRANCHING)
STORM DRAIN SHALL BE 12 " AND 8" DIA RCPC MAIN AND 6" DIA BRANCHING AND 4" DIA FOR ENDLINES
VENT PIPE SHALL BE POLYVINYL (PVC) PIPE, SERIES 900 OR APPROVED EQUAL. FITTINGSHALL BE PVC WITH SOLVENT CEMENTJOINT TO ASTM D2564
WATER LINE SHALL BE uPVC
WATER METER WATER METER SHALL BE "ARAD", ASAHI" BRAND OR APPROVED EQUAL.
CVGV
WMM
LAVLAV
F
SHOF
SHO
F
SHOLAV
WC
WC
WC
F
SHO
WC
WC
LAV
LAVWC
F
SHO
SINK
RISER
RISER
LAV
WC
LAV
WC
SINK
U
P
9
3
10
WATER SUPPLY PLUMBING LAYOUT
(ISOMETRIC VIEW)
GENERAL NOTES
LEGEND
MATERIAL SPECIFICATIONS
I S O M E T R I C V I E W
N O T D R A W N T O S C A L EP
WATER SUPPLY PLUMBING LAYOUT
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:
DATE:
PTR NO:
SANITARY ENGINEER / MASTER PLUMBER
SHEET CONTENT:PROJECT TITLE:APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
PRC NO:
DATE:
TIN NO:
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
PL
PL PL PL
PLPL PL
PLPL
DLDL
DL
DL
DL DL
DL DL
WL WL
WL WL
S1 S1
S1 S1
S1
S1
S1
S3 S3
S1
S3
S1
S1
S2S2 S2
S2
PB1
5
4
3
2
1
CM CM CM CM
CM CM
CM
ACU ACU
ACUACU
ACU
ACU
PB1
6
7
13
9 11
10
8
12
14
UPDOWN
PB2
ACU
ACU ACU
ACU
ACU
NOTE:- SECOND FLOOR CONVENIENCE OUTLET
LAYOUT IS FOR ROUGHING-INS ONLY.- ALL EXPOSED ROUGH-IN PIPES MUST BE
SECURED OR PLUGGED UNTIL PHASE-IIUTILIZATION.
PANEL BOARD
POWER SERVICE ENTRANCE
M KILOWATT HOUR METER
CIRCUIT BREAKER
GROUND
1 CIRCUIT HOME RUN
S2 2-GANG SWITCH
S3 3-GANG SWITCH
ELECTRICAL SYMBOLS:
CIRCUIT HOME RUN LINE
CONVENIENCE OUTLET LINE
PL
DL
S1 1-GANG SWITCH
6"Ø PIN LIGHT
6"Ø CEILING MOUNTED DOWN LIGHT
DOUBLE LED TROFFER LIGHTING (FLUSH)
COMPACT FLUORESCENT LAMP SCREW-IN
SWITCH LINE
TTB TERMINAL BLOCK (TELEPHONE TERMINAL BLOCKWITH COVER)
AIR CONDITIONING UNITACU
WEATHER PROOF OUTLETWP
DUPLEX CONVENIENCE OUTLET
WL UP/DOWN WALL LIGHT (WARM WHITE)
DOUBLE LED TROFFER LIGHTING (CEILING MOUNTED)
SINGLE LED TROFFER LIGHTING (FLUSH)
SINGLE LED TROFFER LIGHTING (CEILING MOUNTED)
CM
CM
GENERAL NOTES:1. ALL ELECTRICAL WORKS HEREIN SHALL COMPLY WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE RULESAND REGULATIONS OF THE LOCAL UTILITY COMPANY AND THE LAWS AND ORDINANCES OF THE LOCAL ENFORCING AUTHORITIESCONCERNED.THE ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF COMPETENT DULY LICENSEDELECTRICAL ENGINEER.
2. POWER SERVICE ENTRANCE VOLTAGE SHALL BE 220 VOLTS, 60 Hz, 1Ø,3W AS SHOWN ON THE DRAWING.
3. MINIMUM SIZE OF CONDUCTOR AND CONDUIT TO BE USED SHALL BE3.5mm TYPE 'TW' STRANDED AND 15mm INTERNALDIAMETER, RESPECTIVELY.
4. WIRING LAYOUT ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL WIRE THE SYSTEM TO ATTAIN ITS INTENDED FUNCTION EVENWIRES ARE NOT INDICATED ON PLANS.
5. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANEL BOARDS, LIGHTING FIXTURES AND ALL NON-CURRENT CARRYINGMETAL PARTS SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICALCODE.
6. SERVICE ENTRANCE CONDUIT SHALL BE IN RIGID STEEL CONDUIT.
7. UNLESS OTHERWISE SPECIFIED, PULL BOXES OR JUNCTION BOXES SHALL BE PROVIDED WHENEVER REQUIRED ANDNECESSARY, ALTHOUGH SUCH BOXES ARE NOT INDICATED ON PLANS.
8. USE BOLT-ON TYPE CIRCUIT BREAKERS.
9. WIRING LAYOUT IN GENERAL SHALL BE IN POLYVINYL CHLORIDE CONDUIT (PVC) SCH. 40 HIGH IMPACT TYPE.
10. ALL WIRING DEVICES ARE APPROXIMATE LOCATION ONLY, ACTUAL SETTING CAN BE MOVED WITHIN 3.0 METERS WITHOUTADDITIONAL COST TO THE OWNER.
11. THE CONTRACTOR SHALL CONDUCT MEAGER TEST ON ALL WIRES.
3-30 mm² THHN WIREIN 32mmɸ RSC/PVC
CONDUIT PIPE
SERVICEENTRANCE
M
GROUND LINE
3 4
21L.O.15A
15A 15A
L.O.
L.O.
L.O.
100A
PB2
5 6
15AC.O.
7 8
20AC.O.
9 10
30AACU
ACU ACU
SPARE SPARE
ACU
C.O.
12
16
11
15
15A
20A
30A
30A 30A
1413ACU ACU30A 30A
L.O.20A
7
WATTS
LIGHTING OUTLET
VOLTS AMPS CIRCUITBREAKER
SIZE OF WIRE
220 15A
L.O.
3.18
TOTAL LOAD: 16,260W/220V = 73.91A
2 - 2.0 mm²Ø THHN STRANDED WIRE
C.O.
220
PB-01 ELECTRICAL LOAD SCHEDULE:
SIZE OF CONDUITCIRCUITNO.
1
3
2
TOTAL:
5
4
6
LOAD DESCRIPTION
LIGHTING OUTLET 9
11
700W
900W
1100W
2 - 2.0 mm²Ø THHN STRANDED WIRE15A
16,2602845 73.91
WIRE:3-30 mm² THHN WIRE IN 32mmɸ RSC/PVC CONDUIT PIPEBREAKER: 220V, 100A CIRCUIT BREAKER
15mm Ø. PVC
15mm Ø. PVC
4.09
5.00
8
7
10
9
1
1440W
20mm Ø. PVC
1
6.55
20mm Ø. PVC
20mm Ø. PVC2 - 3.5 mm²Ø THHN STRANDED WIRE
2 - 3.5 mm²Ø THHN STRANDED WIRE
11 1 20mm Ø. PVC2 - 3.5 mm²Ø THHN STRANDED WIRE
16 SPARE
CONVENIENCE OUTLET
LIGHTING OUTLET
1300W
7
8
7 20mm Ø. PVC2 - 3.5 mm²Ø THHN STRANDED WIRE
2 - 2.0 mm²Ø THHN STRANDED WIRE15A 15mm Ø. PVC
5.91 30A
20A
20mm Ø. PVC
1260W 5.73
30A
30A
9 900W 4.09LIGHTING OUTLET 2 - 2.0 mm²Ø THHN STRANDED WIRE15A 15mm Ø. PVC
9 900WLIGHTING OUTLET 2 - 2.0 mm²Ø THHN STRANDED WIRE15A 15mm Ø. PVC
12 1 20mm Ø. PVC2 - 3.5 mm²Ø THHN STRANDED WIRE30A
13 1 20mm Ø. PVC2 - 3.5 mm²Ø THHN STRANDED WIRE30A
14 1 20mm Ø. PVC2 - 3.5 mm²Ø THHN STRANDED WIRE30A
15 SPARE
CONVENIENCE OUTLET
CONVENIENCE OUTLET
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
1300W 5.91
1300W 5.91
1300W 5.91
1300W 5.91
1300W 5.91
1260W 5.73
2 - 3.5 mm²Ø THHN STRANDED WIRE20A
2 - 3.5 mm²Ø THHN STRANDED WIRE20A
4.09
E
10
1
10
LIGHTING OUTLET LAYOUT
CONVENIENCE OUTLET LAYOUTS
PANEL BOARD DIAGRAM
GENERAL NOTES
ELECTRICAL SYMBOLS
ELECTRICAL LOAD SCHEDULE
L I G H T I N G O U T L E T L A Y O U T
SCALE:E
1:100mts.
G R O U N D F L O O RC O N V E N I E N C E O U T L E T L A Y O U T
SCALE:E
1:100mts.
R O O F D E C K
C O N V E N I E N C E O U T L E T L A Y O U T
SCALE:E
1:100mts.
G R O U N D F L O O RPANEL BOARD DIAGRAM
N O T D R A W N T O S C A L EE
4 4
F:\INSTITUTIONAL - CIVIL SERVICE COMMISSION\JPEG\unnamed.jpg
SHEET NO:
LOCATION: GOVERNMENT CENTER, PALO, LEYTE
"CONSTRUCTION OF CSC RO-VIII HUMAN
RESOURCE TRAINING CENTER PHASE-01"
SIGN & SEALED:SHEET CONTENT:PROJECT TITLE:
APPROVED BY:
REGIONAL DIRECTOR - CSC VIII
VICTORIA F. ESBER
T
OWNER: REVIEWED BY: RECOMMENDING APPROVAL:
SUPERVISING HR SPECIALIST
RESIDENT PROJECT COORDINATOR/IMPLEMENTOR
ARIEL M. JAVIER
DATE:
PTR NO:
PROFESSIONAL ELECTRICAL ENGINEER
PRC NO:
DATE:
TIN NO: