table of contents - dominion industrial2 littleton, co usa phone 303-794-2611 fax 303-795-9487 1/97...

66
1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1 Table of Contents Compressed Air Systems ......................................................................2 Filter Operation .......................................................................................4 General Purpose Filters .......................................................................6 Oil Removal (Coalescing) Filters .........................................................8 Oil Vapor Removal (Adsorbing) Filters ..............................................10 Ultraire Filters .....................................................................................12 Regulator Operation .............................................................................14 General Purpose Regulators .............................................................16 General Purpose Regulators .............................................................18 Pilot and Precision Regulators ...........................................................20 Pilot Operated Regulators..................................................................22 Micro-Trol ® Regulator .......................................................................24 Water Regulators ...............................................................................26 Cylinder Gas Regulators ....................................................................28 Gauges...............................................................................................29 Filter/Regulator Operation ...................................................................30 General Purpose Filter/Regulators ....................................................32 Instrument Filter/Regulators ...............................................................34 Lubricator Operation ............................................................................36 Micro-Fog Tool ® Lubricators .............................................................38 Oil Fog Tool Lubricators.....................................................................40 Micro-Fog ® and Oil-Fog Lubricators with Large Reservoirs .............42 Bearing Lubricators ............................................................................44 Combination Unit Operation ................................................................46 Micro-Fog ® Combination Units .........................................................48 Oil-Fog Combination Units .................................................................50 Relief Valve Operation..........................................................................52 General Purpose Relief Valves ..........................................................54 Miniature Relief Valves ......................................................................56 Water Relief Valves ...........................................................................58 Miscellaneous Blow Gun............................................................................................60 Drip Leg Drain ....................................................................................61 Needle Valves ....................................................................................62 Differential Pressure Indicator ............................................................63 Sizing Filters, Regulators, and Lubricators .......................................64 Rating Filter Elements and ISO Standard 8573-1 ..............................65 Warning/Warranty .................................................................................66 NCA-42 January 1997 Supersedes August 1994

Upload: others

Post on 11-Mar-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1

Table of Contents

Compressed Air Systems ......................................................................2Filter Operation .......................................................................................4

General Purpose Filters .......................................................................6Oil Removal (Coalescing) Filters .........................................................8Oil Vapor Removal (Adsorbing) Filters ..............................................10Ultraire Filters.....................................................................................12

Regulator Operation .............................................................................14General Purpose Regulators .............................................................16General Purpose Regulators .............................................................18Pilot and Precision Regulators...........................................................20Pilot Operated Regulators..................................................................22Micro-Trol ® Regulator .......................................................................24Water Regulators ...............................................................................26Cylinder Gas Regulators....................................................................28Gauges...............................................................................................29

Filter/Regulator Operation ...................................................................30General Purpose Filter/Regulators ....................................................32Instrument Filter/Regulators...............................................................34

Lubricator Operation ............................................................................36Micro-Fog Tool ® Lubricators.............................................................38Oil Fog Tool Lubricators.....................................................................40Micro-Fog ® and Oil-Fog Lubricators with Large Reservoirs.............42Bearing Lubricators ............................................................................44

Combination Unit Operation ................................................................46Micro-Fog ® Combination Units .........................................................48Oil-Fog Combination Units.................................................................50

Relief Valve Operation ..........................................................................52General Purpose Relief Valves..........................................................54Miniature Relief Valves ......................................................................56Water Relief Valves ...........................................................................58

MiscellaneousBlow Gun............................................................................................60Drip Leg Drain....................................................................................61Needle Valves ....................................................................................62Differential Pressure Indicator............................................................63

Sizing Filters, Regulators, and Lubricators .......................................64

Rating Filter Elements and ISO Standard 8573-1 ..............................65

Warning/Warranty .................................................................................66

NCA-42January 1997

Supersedes August 1994

Page 2: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Compressed Air Systems and Air

Air Preparation ProductsDryers

When air iscompressed,the water con-tent for agiven volumeof air increas-es. When theair flowsthrough thecompressedair line, watercondensateforms inside the pipeline. If not removed,this moisture can rust pipes, shorten com-ponent life, clog air lines and reduce airflow, which all contribute to costly down-time. Water will also cause imperfectionsin spray-painted surfaces and surfacecontamination in blow-off applications.Installing an dryer removes this watervapor before it condenses in the line or indownstream equipment.

Compressed Air Systems

An efficient compressed air system doesnot just happen – it is the product of goodplanning.

An efficient system ensures minimumpressure loss in the distribution networkand the removal of contaminants (water,compressor oil, dirt, rust, pipe scale andother foreign materials).

An efficient system results in lower costsper unit of compressed air, proper tooloperation, increased component life,increased flow capacity and the reductionof sludge and rust in the main and branchlines. The system layout shown on page 3is a typical installation. The location ofcomponents may vary with any installa-tion.

Compressed Air Preparation

Before compressed air can be used topower an air driven device, it must beproperly prepared. For example, it mustbe dried, cleaned, regulated to a pressurerequired to operate the device and, insome cases, lubricated to reduce frictionin the device.

Devices that prepare compressed air foruse in air-driven tools are often calledconditioners.

Filters

Contaminants from the atmosphere (dust,moisture, pollutants)are drawn into the airsystem at the compres-sor intake. Sludge, oiland foreign matter maybe added to the airsystem by the com-pressor itself. Suchcontaminated air caninterfere with the airdriven device operationand, in time, damage it.Compressed air filters, installed upstreamfrom the air driven device, remove thesecontaminants as well as most water con-densate from the flowing compressed air.

Some applications require extremelyclean air virtually free of oil aerosols,vapors, and hydrocarbons. Oil removal(coalescing) and oil vapor removal(adsorbing) filters are used in these appli-cations.

Regulators

Air driven devices are designed to work ata certain pressure.Most devices will oper-ate at pressures inexcess of that recom-mended. However,operating at higherpressures can causeexcess torque, forceand wear and canwaste compressed air.The best operation andlife of the device canbe obtained by using the correct pressurelevel. A regulator is used to reduce andmaintain the pressure at a level requiredby the device.

Filter/Regulators

A filter/regulator com-bines the functions ofa filter and a regulator,as described in theprevious paragraphs,into one compactspace- saving unit.

Lubricators

Most moving parts require some type oflubrication. The efficien-cy of cylinders, valvesand air motors can begreatly improved if theyare supplied with therequired lubrication.

Air driven devices canbe lubricated by usingan air line lubricator, adevice for adding lubri-cating oil in aerosolform into the com-pressed air line. The air passing throughthe lubricator transports the lubricant to airtools, cylinders or other air driven deviceswhere the lubricant is deposited on mov-ing and sliding surfaces to reduce frictionand wear.

Most lubricators have a proportional oildelivery feature which automatically pro-vides a nearly constant oil-to-air ratio overa wide range of air flows.

Page 3: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 3

Lockout Valve

GeneralPurpose Filter

Oil RemovalFilterAir

Dryer

PressureGuage

PilotRegulator

Pilot Operated(Slave) Regulator Modular Excelon System

• Lockout Valve• Filter/Regulator• Lubricator

AIR OPERATED TOOLS

PAINT SPRAYIN

COMPRESSEDAIR FROMRECEIVER

Lockout Valve

Filter/Regulator

SolenoidValve

BearingLubricator

Lockout Valve

Filter Regulator Lubricator

Wye

Reclassifieres

A→

CYLINDERS

MACHINELUBRICATION

Drip LegDrain

Filter/Regulator

Oil RemovalFilter Vapor

Removal FilterULTRA CLEAN AIR FORCRITICAL APPLICATIONS

Lockout Valve

B→

Drip LegDrain

A

BModular Excelon System• Lockout Valve• Filter/Regulator• Oil Removal Filter

Page 4: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

4 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Filter Operation

General Purpose Filters

Remove liquids and solid particles down to 5 microns, depending on theselected filter element rating.

Use for most industrial applications, such as factory compressed air lines andmachinery, and as a prefilter for the Oil Removal (Coalescing) Filter.

Oil Removal (Coalescing) Filters

Remove submicron solid particles and oil aerosols down to 0.01 micron.Maximum remaining oil content of air leaving the filter is 0.01 ppm at 70°F(21°C) with an 10 ppm inlet concentration.

Use in industrial applications that require a very clean air supply virtually freefrom oil aerosols and as a prefilter for the Oil Vapor Removal (Adsorbing)Filter.

NOTE: For a maximum service life and efficiency, oil removal filters should beprotected upstream by a 5-micron general purpose filter.

Oil Vapor Removal (Adsorbing) Filters

Remove oil vapors. Maximum remaining oil content of air leaving the filter is0.003 ppm at 70°F (21°C) within rated conditions.

Use in industrial applications that demand instrument grade air.

NOTE: Vapor removal filters MUST be protected upstream by an oil removalfilter.

NOTE

These filters will remove most liq-uid and solid particles from thecompressed air. Water vapor,however, will pass through the fil-ters and could condense into liquidform downstream. Install an airdryer if water condensationwill have a detrimental effect onthe application.

Filter Graphic Symbols

Automatic Drain Manual Drain

Page 5: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 5

Standard Service Life Indicator — Senses air pressure upstream and downstream from the filterelement. The indicator shows green when the pressure drop is below 5 psid. As pressure differen-

tial increases across the filter element with retention of solid particles, the indicator changes fromgreen to red. When the indicator shows more red than green, the pressure differential

is in excess of 10 psid and the element should be replaced.

Coalescing Element — Coalesces submicron oil aerosols into large, heavy drops that flowdownward through the element sidewall and drop to the bowl bottom. Also removes

submicron solid particles.

Manual or Automatic Drain — Dumps accumulated liquids.

Activated Carbon Cartridge Element — Acts as an adsorbent to remove oil vapors. Ultrahigh efficiency of the carbon element optimizes air velocity and contact time to reduce the

maximum oil content in the air leaving the filter to 0.003 ppm at 70°F (21°C).

Optional Service Life Indicator — Senses air pressure upstream and downstream from the filterelement. The indicator shows green when the pressure drop is below 5 psid. As pressure differen-

tial increases across the filter element with retention of solid particles, the indicator changes fromgreen to red. When the indicator shows more red than green, the pressure differential

is in excess of 10 psid and the element should be replaced.

Louvers — Air entering the filter is guided into a swirling pattern by the louvers. Coarse solid particles and liquids are forced to the bowl wall by centrifugal force and drop to the bottom.

Filter Element — Removes most solid particles.

Baffle — Creates a quiet zone at the bowl bottom and prevents air turbulence from pickingup liquids and returning them to the air stream.

Manual or Automatic Drain — Dumps accumulated liquids.

Filter Operation

Page 6: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

6 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

General Purpose Filters1/8" thru 2" Port Sizes

● Cleanable, depth-type filter element has extra largesurface area for long service life.

● Excellent water removal characteristics.

● Depth type 40 µm or 5 µm filter elements. Particleremoval per ISO 8573-1, Class 5 and Class 3.

● Optional service life indicator (not available on theF07) changes from green to red when the elementneeds to be replaced.

MODEL NUMBERSAutomatic Drain†† Manual Drain

Port Filter Metal Bowl Transparent Metal Bowl TransparentSize Flow † Element with Sight Polycarbonate with Sight Polycarbonate

Type PTF scfm (dm3/s) Rating Glass Bowl Glass Bowl Catalog

F07 1/8 18 (8.5) 5µm F07-100-A1MA * F07-100-A1TA F07-100-M1MA * F07-100-M1TA NC-1231/4 21 (9.9) 5µm F07-200-A1MA * F07-200-A1TA F07-200-M1MA * F07-200-M1TA

F72 1/4 53 (25) 40µm F72G-2AN-SD3 F72G-2AN-AL3 F72G-2AN-QD3 F72G-2AN-QT3 NC-1443/8 53 (25) 40µm F72G-3AN-SD3 F72G-3AN-AL3 F72G-3AN-QD3 F72G-3AN-QT3

F08 1/4 50 (24) 40µm F08-200-A3DA F08-200-A3TA F08-200-M3DA F08-200-M3TA NC-1263/8 65 (31) 40µm F08-300-A3DA F08-300-A3TA F08-300-M3DA F08-300-M3TA1/2 70 (33) 40µm F08-400-A3DA F08-400-A3TA F08-400-M3DA F08-400-M3TA

F74 3/8 120 (57) 40µm F74G-3AN-AD3 F74G-3AN-AP3 ** F74G-3AN-QD3 F74G-3AN-QP3 ** NC-1371/2 150 (71) 40µm F74G-4AN-AD3 F74G-4AN-AP3 ** F74G-4AN-QD3 F74G-4AN-QP3 **3/4 185 (87) 40µm F74G-6AN-AD3 F74G-6AN-AP3 ** F74G-6AN-QD3 F74G-6AN-QP3 **

F17 3/4 325 (153) 40µm F17-600-A3DA — F17-600-M3DA — NC-1261 425 (201) 40µm F17-800-A3DA — F17-800-M3DA —

1-1/4 425 (201) 40µm F17-A00-A3DA — F17-A00-M3DA —1-1/2 425 (201) 40µm F17-B00-A3DA — F17-B00-M3DA —

F18 1-1/2 1300 (614) 40µm F18-B00-A3DA — F18-B00-M3DA — NC-1242 1300 (614) 40µm F18-C00-A3DA — F18-C00-M3DA —

Options. Change model number as follows:Service Life Indicator (not available on F07) –

F08, F17, F18: Use 01 in the 5th and 6th position.F72, F74: Use D in 7th position.

5µm Filter Element –F07, F08, F17, F18: Use 1 in the 8th position.F72, F74: Use 1 in 10th position.

Metal Bowl without Sight Glass –F07, F17, F18 only: Use M in the 9th position.

ISO G Ports –F07, F08, F17, F18: Use G in the 10th position.F72, F74: Use G in 6th position.

ISO Rc Ports –F07, F08, F17, F18: Use B in the 10th position.F72, F74: Use B in 6th position.

Field AccessoriesWall Mounting Brackets –

F07: 5939-06F08: 3783-52F17 –

3/4" & 1" Ports: 6212-50 1-1/4" & 1-1/2" Ports: 6212-51

F18: Not availableF72: 4224-50F74: 4324-50

Service Life Indicator Field Conversion Kit (F08and F74 only): 5797-50

Panel Mounted Service Life Indicator: 18-033-025

Replacement ElementsType 5-micron 40-micron

F07 5726-04 5726-05F08 3161-16 3161-18F17 5311-01 5311-03F18 5882-11 5882-13F72 5925-03 5925-02F74 4338-04 4338-05

* The F07 metal bowl is not available with a sight glass.** The F74 filter includes a metal bowl guard with transparent bowl.† Approximate flow at 100 psig (6.9 bar) inlet pressure and 5 psid (0.3 bar) pressure drop.†† Semiautomatic drain on the F72 with metal bowl; diaphragm style spitter drain on the F07.

Ordering Information

Page 7: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7

General Purpose Filters

SpecificationsFluid: Compressed airMaximum Inlet Pressure –

Transparent Bowl: 150 psig (10.3 bar)Metal Bowl: 250 psig (17.2 bar)

Maximum Temperature –Transparent Bowl: 125°F (52°C)Metal bowl –

F72: 150°F (65°C)All Others: 175°F (79°C)

Automatic Drain Connection –F07: 1/8" pipeF08, F17, F18, F74: 1/8" NPTFF72: ISO R1/8

Manual Drain Connection –F07: 1/8" pipeF08, F17, F18: NoneF72, F74: 7/16-24 for 1/4" tube nut and

ferruleF72 semiautomatic drain connection: Push on

5/16" ID flexible tube

NotesAutomatic drains operate when liquid accu-

mulates above a certain level. Spitter drainsoperate when a rapid change in flow occurs. Semiautomatic drains open when the filter isdepressurized.

Water vapor will pass through these filtersand could condense into liquid form downstreamas air temperature drops. Install a Norgren airdryer if water vapor could have a detrimentaleffect on the application.

Materials of ConstructionBody –

F07, F08, F72: ZincF17, F18, F74: Aluminum

Bowl –Transparent: PolycarbonateMetal –

F07, F08, F18, F72: ZincF17, F74: Aluminum

Metal Bowl Sight Glass –F08, F17, F18: PyrexF72, F74: Transparent nylon

Element –F07, F08, F72, F74: Porous polypropyleneF17, F18: Sintered bronze

Elastomers: Neoprene and nitrileOptional Service Life Indicator –

Body: Transparent nylonInternal Parts: AcetalSpring: Stainless steelElastomers: Nitrile

A

BS

CD

H

KE

G

Port CL

FJ

L

K

JE

FG

Port CL

H

E

G

F

M

H

JN

L

K

E

F

G

M L

J

N K

PR

H

Port CL

Port CL

F74 Shown, Others Similar 5939-06 (F07) 3783-52 (F08) 6212-50 & 6212-51 (F17)4224-50 (F72)4324-50 (F74)

Dimensions in inches (mm).B D

Max. Auto. Man.Type A Dia. C Drain Drain E F G H J K L M N P R S

F07 1.63 1.45 0.38 3.72 3.87 1.50 2.05 1.34 1.60 1.02 0.63 0.51 0.22 0.32 — — —(42) (37) (10) (95) (98) (38) (52) (34) (41) (26) (16) (13) (6) (8) — — —

F72 1.98 1.91 0.75 5.43 5.27* 1.65 2.36 1.50 2.00 1.54 0.24 0.47 0.79 0.20 0.16 0.71 1.36(50) (48) (19) (138) (134) (42) (60) (38) (51) (39) (6) (12) (20) (5) (4) (18) (35)

F08 2.75 2.68 0.67 5.70 6.08 3.56 1.50 2.40 1.00 0.25 1.50 0.27 (6) — — — — 1.36(70) (68) (17) (145) (154) (90) (38) (61) (25) (6) (38) Dia. — — — — (35)

F74 3.15 2.89 1.00 6.35 6.95 2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77 1.36(80) (74) (25) (161) (177) (69) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20) (35)

F17 4.75 5.52 1.25 10.06 10.44 5.13 1.69 3.00 0.34 (9) 3.91 1.00 — — — — — 1.36(121) (140) (32) (256) (265) (130) (43) (76) Dia. (81) (25) — — — — — (35)

F18 8.22 7.98 1.86 14.82 15.29 — — — — — — — — — — — 1.36(209) (203) (47) (376) (388) — — — — — — — — — — — (35)

* 6.97" (177mm) for semiautomatic drain.

Page 8: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

8 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Oil Removal (Coalescing) Filters1/8" thru 2" Port Sizes

● High efficiency coalescing element removes particles down to 0.01-micron.

● Maximum remaining oil content of air leaving the filteris 0.01 ppm at 70 °F (21°C) with an inlet concentrationof 10 ppm.

● Filters provide Air Quality Class 2 Hydrocarbon andClass 1 Particulate Removal according to ISO 8573-1.

● Standard service life indicator (not available on theF39) changes from green to red when the elementneeds replaced.

Replacement ElementsF39 4141-10F46 5351-04F47 3203-02

F47 High Flow 3203-05F55 5349-05F72 5925-09

F74C 4344-01F74H 4344-02

Ordering Information

* The F39 metal bowl is not available with a sight glass.** The F74 filter includes a metal bowl guard with the transparent bowl.† Approximate flow at 100 psig (6.9 bar) inlet pressure and 5.0 psid (0.3 bar) pres-

sure drop. †† The F39 is not available with a service indicator.

Options. Change model number as follows:Filters without Service Life Indicator –

F55, F46, F47: Use 0 in the 6th position.F72, F74: Use N in 7th position.

Metal Bowl without Sight Glass –F39, F46, F47 only: Use M in the 9th position.

ISO G Ports –F39, F46, F47, F55: Use G in the 10th position.F72, F74: Use G in 6th position.

ISO Rc Ports –F39, F46, F47, F55: Use B in the 10th position.F72, F74: Use B in 6th position.

Field AccessoriesWall Mounting Brackets –

F39: 5939-06F46 –

3/4" & 1" Ports: 6212-50 1-1/4" Ports: 6212-51

F47: Not availableF55: 3783-52F72: 4224-50F74: 4324-50

Service Life Indicator Field Conversion Kit (F55and F74 only): 5797-50

Panel Mounted Service Life Indicator: 18-033-025

MODELS WITH SERVICE INDICATOR †

Automatic Drain††† Manual DrainPort Recommended Metal Bowl Transparent Metal Bowl TransparentSize Flow † Prefilter with Sight Polycarbonate with Sight Polycarbonate

Type PTF scfm (dm3/s) Type Glass Bowl Glass Bowl Catalog

F39 1/8 4 (1.8) F07 F39-100-A0MA * F39-100-A0TA F39-100-M0MA * F39-100-M0TA NC-1211/4 4 (1.8) F07 F39-200-A0MA * F39-200-A0TA F39-200-M0MA * F39-200-M0TA

F72C 1/4 11 (4.4) F72G F72C-2AD-SD0 F72C-2AD-AL0 F72C-2AD-QD0 F72C-2AD-QT0 NC-1453/8 11 (4.4) F72G F72C-3AD-SD0 F72C-3AD-AL0 F72C-3AD-QD0 F72C-3AD-QT0

F55 1/4 15 (7.1) F08 F55-201-L0DA F55-201-L0TA F55-201-M0DA F55-201-M0TA NC-1163/8 15 (7.1) F08 F55-301-L0DA F55-301-L0TA F55-301-M0DA F55-301-M0TA

F74C 3/8 20 (9.5) F74G F74C-3AD-AD0 F74C-3AD-AP0 ** F74C-3AD-QD0 F74C-3AD-QP0 ** NC-1381/2 35 (16.5) F74G F74C-4AD-AD0 F74C-4AD-AP0 ** F74C-4AD-QD0 F74C-4AD-QP0 **

F74H 1/2 60 (28.0) F74G F74H-4AD-AD0 F74H-4AD-AP0 ** F74H-4AD-QD0 F74H-4AD-QP0 ** NC-138High Flow 3/4 60 (28.0) F74G F74H-6AD-AD0 F74H-6AD-AP0 ** F74H-6AD-QD0 F74H-6AD-QP0 **

F46 3/4 90 (42.0) F17 F46-601-A0DA — F46-601-M0DA — NC-1161 125 (59.0) F17 F46-801-A0DA — F46-801-M0DA —

1-1/4 125 (59.0) F17 F46-A01-A0DA — F46-A01-M0DA —

F47 1-1/2 250 (118.0) F17 F47-B01-A0DA — F47-B01-M0DA — NC-1252 300 (142.0) F18 F47-C01-A0DA — F47-C01-M0DA —

F47 2 600 (284.0) F18 F47-C21-A0DA — F47-C21-M0DA — NC-125High Flow

††† Semiautomatic drain on the F72 with metal bowl; diaphragm style spitter drainon the F07.

Page 9: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 9

Oil Removal (Coalescing) Filters

SpecificationsFluid: Compressed airMaximum Inlet Pressure –

Transparent Bowl: 150 psig (10.3 bar)Metal Bowl: 250 psig (17.2 bar)

Maximum Temperature –Transparent Bowl: 125°F (52°C)Metal Bowl: 150F (66°C)

Automatic Drain Connection –F39: 1/8" pipeF55, F46, F47, F74: 1/8" NPTFF72: ISO R1/8

Manual Drain Connection –F39: 1/8" pipeF55, F46, F47: NoneF72, F74: 7/16-24 for 1/4" tube nut and

ferruleF72 semiautomatic drain connection: Push on

5/16" ID flexible tubeMaximum Pressure Drop Across Filter for

Efficient Operation: 10 psig (0.7 bar)

Materials of ConstructionBody –

F39, F55, F72: ZincF46, F47, F74: Aluminum

Bowl –Transparent: PolycarbonateMetal –

F39, F55, F47, F72: ZincF46, F74: Aluminum

Metal Bowl Sight Glass –F55, F46, F47: PyrexF72, F74: Transparent nylon

Element: Synthetic fiber and polyurethane foamElastomers: Neoprene and nitrileService Life Indicator –

Body: Transparent nylonInternal Parts: AcetalSpring: Stainless steelElastomers: Nitrile

NotesAutomatic drains operate when liquid accu-

mulates above a certain level. Spitter drainsoperate when a rapid change in flow occurs. Semiautomatic drains open when the filter isdepressurized.

Water vapor and oil vapor will pass throughthese filters and could condense into liquid formdownstream as air temperature drops. Install aNorgren air dryer and oil vapor removal filter ifwater and oil vapor could have a detrimentaleffect on the application.

For maximum service life, install a generalpurpose filter with a 5 µm element upstreamfrom the oil removal filter.

Dimensions in inches (mm).B D

Max. Auto. Man.Type A Dia. C Drain Drain E F G H J K L M N P R S

F39 1.63 1.45 0.38 3.72 3.87 1.50 2.05 1.34 1.60 1.02 0.63 0.51 0.22 0.32 — — —(42) (37) (10) (95) (98) (38) (52) (34) (41) (26) (16) (13) (6) (8) — — —

F72C 1.98 1.91 0.75 5.43 5.27* 1.65 2.36 1.50 2.00 1.54 0.24 0.47 0.79 0.20 0.16 0.71 1.36(50) (48) (19) (138) (134) (42) (60) (38) (51) (39) (6) (12) (20) (5) (4) (18) (35)

F55 2.75 2.68 0.67 5.70 6.08 3.56 1.50 2.40 1.00 0.25 1.50 0.27 (6) — — — — 1.36(70) (68) (17) (145) (154) (90) (38) (61) (25) (6) (38) Dia. — — — — (35)

F74C 3.15 2.89 1.00 6.35 6.95 2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77 1.36(80) (74) (25) (161) (177) (69) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20) (35)

F74H 3.15 2.89 1.00 8.44 9.04 2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77 1.36High Flow (80) (74) (25) (215) (230) (69) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20) (35)

F46 4.75 5.52 1.25 10.06 10.44 5.13 1.69 3.00 0.34 (9) 3.91 1.00 — — — — — 1.36(121) (140) (32) (256) (265) (130) (43) (76) Dia. (81) (25) — — — — — (35)

F47 8.22 7.98 1.86 14.82 15.29 — — — — — — — — — — — 1.36(209) (203) (47) (376) (388) — — — — — — — — — — — (35)

F47 8.22 7.98 1.86 23.44 23.82 — — — — — — — — — — — 1.36High Flow (209) (203) (47) (595) (605) — — — — — — — — — — — (35)

A

BS

CD

H

KE

G

Port CL

FJ

L

K

JE

FG

Port CL

H

E

G

F

M

H

JN

L

K

E

F

G

M L

J

N K

PR

H

Port CL

Port CL

F74 Shown, Others Similar 5939-06 (F39) 3783-52 (F55) 6212-50 & 6212-51 (F46)4224-50 (F72)4324-50 (F74)

* 6.97" (177mm) for semiautomatic drain.

Page 10: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

MODEL NUMBERS

Port Recommended OilSize Flow * Removal (Prefilter) Metal

Type PTF scfm (dm3/s) Type Bowl Catalog

F74V 3/8 21 (10) F74C or H F74V-3AN-EMA NC-1391/2 21 (10) F74C or H F74V-4AN-EMA3/4 21 (10) F74C or H F74V-6AN-EMA

F46 3/8 36 (17.0) F74C or H F46-323-MAGA NC-130Compact 1/2 36 (17.0) F74C or H F46-423-MAGA

F46 1/2 60 (28.3) F46 F46-424-MAMA NC-1303/4 60 (28.3) F46 F46-624-MAMA

F46 1 100 (47.2) F46 F46-827-MAMAHigh Flow

10 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Oil Vapor Removal (Adsorbing) Filters3/8" thru 1" Port Sizes

● Activated carbon element acts as an adsorbent inremoving oil vapors and odors.

● Filter and element designs optimize air velocityand contact time to reduce the oil content in theair leaving the filter to 0.003 ppm at 70 °F (21°C).

● Long service life of carbon cartridge element.Minimum service life of 400 hours can be expected if the vapor removal filter is protectedupstream by an oil removal (coalescing) filter andif the filtration temperature is in the range of 70 °to 80°F (21° to 26°C). Above this range, oil vaporcontent in compressed air increases substantiallyand element service life is reduced.

Replacement ElementsF46 Compact: 665-07F46: 665-08F46 High Flow: 665-70F74: 4341-01

Field AccessoriesWall Mounting Brackets –

F46: 6212-50F74: 4324-50

Options. Change model number as follows:ISO G Ports –

F46: Use G in 10th position of model numberF74: Use G in 6th position of model number

ISO Rc Ports –F46: Use B in 10th position of model numberF74: Use B in 6th position of model number

Ordering Information

* Approximate flow at 100 psig (6.9 bar) inlet pressure and 5 psid (0.3 bar) pressure drop.

Page 11: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 11

Oil Vapor Removal (Adsorbing) Filters

Dimensions in inches (mm).

B

A

CD

E

F

G

M L

J

N K

PR

H

Port CL

Port CL

F74 Shown, F46 Similar 4324-50 (F74)

SpecificationsFluid: Compressed airMaximum Inlet Pressure: 250 psig (17.2 bar)Maximum Temperature: 150°F (66°C)Maximum Pressure Drop Across Filter Element

for Efficient Operation: 10 psig (0.7 bar)

Materials of ConstructionBody: AluminumBowl: AluminumElement: Activated carbon and aluminumElastomers: Neoprene and nitrile

BMax.

Type A Dia. C D E F G H J K L M N P R

F74V 3.15 2.89 1.00 8.28 2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77(80) (74) (25) (210) (69) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20)

F46 4.75 4.32 1.25 7.99 5.13 1.69 3.00 0.34 (9) — — — — — — —Compact (121) (110) (32) (203) (130) (43) (76) Dia. — — — — — — —

F46 & 4.75 4.32 1.25 10.44 5.13 1.69 3.00 0.34 (9) — — — — — — —F46 High Flow (121) (110) (32) (265) (130) (43) (76) Dia. — — — — — — —

NotesOil vapor removal filters must be protected

upstream by an oil removal filter. Select aNorgren oil removal filter with equivalent pipesize and flow capacity equal to or greater thanthe vapor removal filter.

K

JE

FG

Port CL

H

6212-50 (F46)

Page 12: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

12 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Ultraire Combination Filter1/4", 3/8", 1/2" Port Sizes

● Olympian plug in design

● Includes integral prefilter , coalescing, and adsorbingelements

● Oil and dirt contamination in outlet air within ISO 8573-1: Quality class 1.7.1

● Activated carbon cartridge filter element adsorbs oilvapors and removes most hydrocarbon odors.

● These filters will not remove carbon monoxide, car -bon dioxide, or other toxic gases or fumes. Do notuse these filters in life support systems or breathingair applications.

Replacement Elements1st Stage Sintered Bronze (F64B/L): 3698-022nd Stage Coalescing (F64B): 5350-992rd Stage Coalescing (F64L): 5350-983rd Stage Activated Carbon (F64B/L): 5568-01

Field AccessoriesWall Mounting Brackets : 74504-50

Options. Change model number as follows:ISO G Ports: Use G in 6th position.ISO Rc Ports: Use B in 6th position.Manual Drain: Use M in 8th position.Transparent Bowls: Use T in 9th position.

Ordering Information

Port RecommendedSize Flow * Prefilter MODELS WITH METAL BOWLS,

Type PTF scfm (dm3/s) Type SIGHT GLASS, AND AUTOMATIC DRAIN Catalog

F64 1/4 16 (7.3) F74G F64B-2AN-AR0 NC-1413/8 24 (11.5) F74G F64L-3AN-AR01/2 24 (11.5) F74G F64L-4AN-AR0

* Approximate flow at 100 psig (6.9 bar) inlet pressure and 5 psid (0.3 bar) pressure drop.

Page 13: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 13

Ultraire Combination Filter

SpecificationsFluid: Compressed airMaximum Pressure –

Transparent bowl: 150 psig (10.3 bar)Metal bowl: 250 psig (17.2 bar)

Maximum Temperature**–Transparent bowl: 125°F (50°C)Metal bowl: 150°F (65°C)

Filter Elements –Integral Prefilter Element: Element (1st

Stage): 40 µmCoalescing Element (2nd Stage): Removes

particles down to 0.01 µm. Maximum remaining oil content of air leaving the coalescing element is 0.01 ppm at 70°F (21°C) with an inlet concentration of 8 ppm.

Adsorbing Element (3rd Stage): Maximum remaining oil content of air leaving filter is 0.003 ppm at +70°C (+21°C).

Automatic drain minimum operating pressure: 10psig (0.69 bar)

** Air supply must be dry enough to avoid iceformation at temperatures below 35°F (2°C).

Materials of ConstructionBody: ZincBowl –

Transparent: PolycarbonateMetal: Zinc

Metal Bowl Liquid Level Indicator Lens: PyrexIntegral Prefilter Element: Sintered bronzeCoalescing Element: Synthetic fiber and

polyurethane foamAdsorbing Element: Activated carbon and alu-

minumElastomers: Neoprene & nitrile

10.6

(27

0) †

11.3

(28

6) *

4.8

(123

)

4.5

(123

)

12.6

(32

0) †

13.2

(33

6) *

1/8 NPT

4.1 (105)

1.5

(37)

2.9

(74)

1/8 NPT

5.6 (143)

4.5 (114)

0.3

(8)

0.4(11)

0.6(15)

3.7

(93)

1.2

(31)

4.4

(110

)

3.4

(85)

1.9

(48)

F64B 74504-50F64L

Dimensions in inches (mm).

* Minimum clearance required to remove bowl. Add 0.28" (7 mm) for models with manual drain.† Add 0.28" (7 mm) for models with manual drain.

NotesThe automatic drain operates when liquid

accumulates above a certain level.Water vapor will pass through these filters

and could condense into liquid form downstreamas air temperature drops. Install a Norgren airdryer if water vapor could have a detrimentaleffect on the application.

For maximum service life, install a Norgrengeneral purpose filter with a 5 µm elementupstream from the oil removal filter.

Page 14: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

14 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Regulator Operation

Operation of a T ypical Regulator

Outlet pressure is controlled by the adjusting knob. Clockwise rotationincreases and counterclockwise rotation decreases the outlet pressure setting.When the knob is rotated fully counterclockwise, no force is applied to theregulation spring, and the valve is held closed by the valve spring. Clockwiserotation of the knob compresses the regulation spring, which supplies a down-ward force on top of the flexible diaphragm. The diaphragm and valve pinmove downward forcing the valve off its seat, which allows air to flow past thevalve to the downstream system. Outlet pressure increases in the down

Operation of a Pilot Operated (Slave) Regulator with aConventional Pilot Regulator

The pilot regulator controls the pressure in the control chamber of the slaveregulator, replacing the spring force as described in Operation of a TypicalRegulator above. This pressure causes the flexible diaphragm and valve tubeof the slave regulator to move downward forcing the valve off its seat, whichallows air to flow past the valve to the downstream system. Outlet pressureincreases in the downstream system and sensing chamber and applies anupward force on the bottom of the diaphragm. The diaphragm, valve tube, andvalve move upward. Upward movement stops when the forces below thediaphragm balance the forces above the diaphragm. When there is no down-stream flow demand, the balance of forces occurs with the valve closed.When there is downstream flow demand, the balance of forces occurs whenthe valve opens sufficiently to compensate for demand, thus maintaining thedesired outlet pressure.

Operation of a Pilot Operated (Slave) Regulator with a FeedbackPilot Regulator

Operation using a feedback regulator is the same as the conventional regula-tor except that outlet pressure of the slave regulator is sensed (through thefeedback line) under the pilot diaphragm, causing the pilot valve to closewhen the desired outlet pressure is achieved. The output of the pilot regulatorwill therefore increase or decrease the pressure into the control chamber asrequired to maintain a constant pressure downstream of the slave regulator.

WARNINGThe feedback line must sense the outlet pressure of the slave regulator andmust be connected before turning on air pressure. If feedback line is not con-nected, slave regulator outlet pressure will rapidly increase to inlet pressurewhen the adjusting knob on the pilot regulator is turned clockwise.

Graphic Symbol — PilotOperated Regulator withConventional Pilot Regulator

Regulator Graphic Symbols

Graphic Symbol — PilotOperated Regulator withFeedback Pilot Regulator

Relieving

PilotRegulator

FeedbackPilotRegulator

Pilot OperatedRegulator

Pilot OperatedRegulator

Nonrelieving

Page 15: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 15

Regulator Operation

stream system and sensing chamber and applies an increasing upward forceon the bottom of the diaphragm. The diaphragm, valve pin, and valve moveupward, compressing the regulating spring. Upward movement stops when theforces below the diaphragm balance the forces above the diaphragm. Whenthere is no downstream flow demand, the balance of forces occurs with thevalve closed. When there is downstream flow demand, the balance of forcesoccurs when the valve opens enough to compensate for demand, thusmaintaining the desired outlet pressure.

CONVENTIONALPILOT REGULATOR

Valve Tube

Valve

Control Chamber

Adjusting Knob

Pilot Pressure Line

Pilot Valve

Sensing Chamber

Diaphragm

SLAVEREGULATOR

Feedback Line

Pilot Diaphragm

FEEDBACKPILOT REGULATOR

SLAVEREGULATOR

AdjustingKnob

RegulatingSpring

Valve Pin

FlexibleDiaphragm

ValveSpring

Valve

SensingChamber

Page 16: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

Ordering Information

16 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

General Purpose Regulators

● Full flow gauge ports

● Low torque, nonrising pressure adjustment knobprovides easy hand adjustment at any pressure.

● Balanced valve with floating pin (all models except theR07) minimizes effect of variation in inlet pressure on theoutlet pressure.

● With the standard relieving regulators, outlet pressurecan be reduced even though the system is dead-ended.

● The R18 integral pilot constant bleed feature providesmaximum sensitivity to system changes.

● Use the R18 Feedback Regulator in applications thatrequire precise pressure control and high flow capability .

1/8" thru 2" Port Sizes

RELIEVING MODELS WITH GAUGEPort Outlet Pressure Adjustment Ranges *Size 1 to 10 psig 5 to 50 psig 5 to 60 5 to 125 psig 5 to 150 psig 10 to 250 psig

Type PTF (0.1 to 0.7 bar) (0.3 to 3.5 bar) (0.3 to 4 bar) (0.3 to 8.6 bar) (0.3 to 10.4 bar) (0.7 to 17.2 bar) Catalog

R07 1/8 R07-100-RGAA R07-100-RGEA — R07-100-RGLA — — NC-2311/4 R07-200-RGAA R07-200-RGEA — R07-200-RGLA — —

R72 1/4 — — R72G-2AK-RFG — R72G-2AK-RMG — NC-2483/8 — — R72G-3AK-RFG — R72G-3AK-RMG —

R08 1/4 — — R08-200-RGFA — R08-200-RGMA R08-200-RGSA NC-2723/8 — — R08-300-RGFA — R08-300-RGMA R08-300-RGSA1/2 — — R08-400-RGFA — R08-400-RGMA R08-400-RGSA

R74 3/8 — — R74G-3AK-RFG — R74G-3AK-RMG R74G-3AT-RSG ** NC-2461/2 — — R74G-4AK-RFG — R74G-4AK-RMG R74G-4AT-RSG **3/4 — — R74G-6AK-RFG — R74G-6AK-RMG R74G-6AT-RSG **

R17 3/4 — R17-600-RGEA — R17-600-RGLA — R17-600-RGSA NC-2721 — R17-800-RGEA — R17-800-RGLA — R17-800-RGSA

1-1/4 — R17-A00-RGEA — R17-A00-RGLA — R17-A00-RGSA1-1/2 — R17-B00-RGEA — R17-B00-RGLA — R17-B00-RGSA

R18 1-1/2 — R18-B05-RGEA — R18-B05-RGLA — R18-B05-RGSA NC-230Conventional 2 — R18-C05-RGEA — R18-CO5-RGLA — R18-C05-RGSA

R18 1-1/2 — — — — — R18-B06-RGSA NC-230Feedback 2 — — — — — R18-C06-RGSA

Options. Change model number as follows:Reverse flow regulators for use downstream of

cycling directional control valves –R74: Use R in 4th position.R08: Use 7 in 6th position.

Low flow seat (R07 only): Use 2 in 6th position.T-handle adjustment –

R08, R17: Use 1 in 6th position.R72, R74: Use T in 7th position.

Nonrelieving regulators –R07, R08, R17, R18: Use N in 7th position.R72, R74: Use N in 8th position.

Regulators without gauge –R07, R08, R17, R18: Use N in 8th positionR72, R74: Use N in 10th position.

ISO G Ports –R07, R08, R17, R18: Use G in 10th position.R72, R74: Use G in 6th position.

ISO Rc Ports –R07, R08, R17, R18: Use B in 10th position.R72, R74: Use B in 6th position.

Field AccessoriesWall Mounting Brackets –

R07: 18-025-003 (includes plastic panel nut)R08: 5203-06 (includes metal panel nut)R17: 5570-04 (includes plastic panel nut)R72: 4224-50R74: 4324-50

Plastic panel nut –R07: 2962-89 R08: 5191-89R17: 5226-89 R74: 4248-89

Metal panel nut –R07: 2962-04 R08: 5191-88R17: 5226-97 R74: 4348-89

Tamper resistant kit –R07: 18-001-092R08: 2117-02R17, R18: 2117-01R72: 4255-51R74: 4355-51

Exhaust muffler R18 relieving models: MB006A

Service KitsType Relieving Nonrelieving

R07 3407-02 3407-01R08 5298-14 5298-13R17 5578-02 5578-01R18 5945-40, 5945-41 5945-40, 5945-41R72 4381-500 4381-501R74 4381-700 4381-701

* Do not use these regulators to control pressures outside of those specified.** R74 regulators with the 250 psig spring are equipped with a T-handle adjustment.

Page 17: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 17

General Purpose Regulators

SpecificationsFluid: Compressed airInlet Pressure –

R07, R08, R17, R72, R74: 300 psig (20.7 bar) maximum

R18: 10 psig (0.7 bar) minimum to 450 psig (31 bar) maximum

Temperature Range –R07, R72: 0° to 150°F (-18° to 66°C)*All Others: 0° to 175°F (-18° to 79°C)*

Gauge Ports –R07, R72: 1/8" PTFAll Others: 1/4" PTF

R18 Pilot Maximum Bleed Rate: The integralpilot regulator used on the R18 has a constantbleed feature which allows a small amount ofair to continuously escape to atmosphere. Themaximum bleed rate is 0.25 scfm (0.12dm3/s)at 50 psig (3.5 bar) outlet pressure.

* Air supply must be dry enough to avoid iceformation at temperatures below 35°F (2°C).

R74 –Body and Bonnet: AluminumValve: BrassElastomers: NitrileBottom Plug: Acetal

Materials of ConstructionR07 –

Body: Zinc Bonnet and Valve Seat: AcetalValve: Brass/NitrileElastomers: Nitrile

R08 –Body and Bonnet: ZincValve: BrassElastomers: NitrileBottom Plug: Acetal

R17 –Body, Bonnet, Bottom Plug: AluminumValve: Aluminum and NylonElastomers: Nitrile

R18 –Body, Bonnet, Bottom Plug: AluminumValve: Aluminum (Teflon on the pilot)Elastomers: Nitrile

R72 –Body: ZincValve: BrassElastomers: NitrileBonnet, Bottom Plug: Acetal

Dimensions in Inches (mm)

J Dia.

HC

A

B

D

K

L

M

P

NRO

T

S

K

L

M

S R

O

T P

U

V

N

Port CL

Port CL

LN

M

K

O

P

S

R

A

J – Dia.

BE

F –

Max

. Pan

elT

hic

knes

s

C

HD

GPanelHoleDia

R18R74 Shown,R07, R08, R17, R72 Similar

* 1.19" for regulators with 3/4" and 1" ports; 1.32" (34mm) for regulators with 1-1/4" and 1-1/2" ports.

4224-50 (R72)4324-50 (R74)18-025-003 (R07)

5203-06 (R08) Shown5570-04 (R17) Similar

C

Type A B Knob T-handle D E F G H J

R07 1.63 0.39 2.91 — 0.75 0.95 0.25 1.19 2.13 1.50(41) (10) (75) — (19) (24) (6) (30) (54) (38)

R72 1.98 1.31 4.19 5.34 0.96 1.01 0.16 1.57 2.34 1.50(45) (33) (106) (135) (24) (26) (4) (40) (59) (38)

R08 2.75 1.44 5.12 5.41 1.00 1.18 0.19 1.89 2.50 2.00(70) (37) (131) (137) (25) (30) (5) (48) (64) (51)

R74 3.15 1.69 6.67 7.64 1.45 1.24 0.25 2.06 3.65 2.00(80) (43) (170) (194) (37) (31) (6) (52) (93) (51)

R17 4.25 2.38 7.09 8.07 1.19* 1.22 0.16 2.28 2.92 2.00(108) (60) (180) (205) (30) (31) (4) (58) (74) (51)

R18 5.98 3.56 9.71 — 2.72 — — — 3.13 2.00Conv. (152) (91) (247) — (69) — — — (80) (51)

R18 5.98 3.56 9.71 — 2.72 — — — 3.13 2.00Feedback (152) (91) (247) — (69) — — — (80) (51)

K L M N O P R S T U V

1.50 2.47 1.41 1.00 0.38 0.69 0.31 0.51 0.22 — —(38) (63) (36) (25) (10) (18) (8) (13) (6) — —

1.65 2.36 1.50 2.00 1.54 0.24 0.47 0.79 0.20 0.16 0.71(42) (60) (38) (51) (39) (6) (12) (20) (5) (4) (18)

2.50 2.75 1.50 1.50 1.00 1.50 0.66 0.28 — — —(64) (70) (38) (38) (25) (38) (17) (7) — — —

2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77(69) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20)

3.50 4.50 3.19 1.75 1.19 2.16 1.08 0.28 — — —(89) (114) (81) (44) (30) (54) (28) (7) — — —

— — — — — — — — — — —— — — — — — — — — — —

— — — — — — — — — — —— — — — — — — — — — —

Page 18: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

18 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

General Purpose Regulators

● Floating valve pin provides more positive seatingand greater dependability .

● Large diaphragm provides accurate and quickresponse to flow demands and line pressurechanges.

● Balanced valve minimizes effect of variations in inletpressure on outlet pressure.

● With standard relieving models, outlet pressure canbe reduced even though the system is dead-ended.

● T-handle adjustment standard; handwheel or screwadjustment optional.

1/4", 3/8", and 1/2" Port Sizes

Service KitsType Port Size

1/4", 3/8" 1/2"Nonrelieving 529-01 535-01Relieving 529-03 535-03

RELIEVING MODELS WITH T-HANDLE ADJUSTMENT

With Gauge Without Gauge Port Outlet Pressure Adjustment Range* Outlet Pressure Adjustment Range*Size 5 to 50 psig 5 to 125 psig 15 to 250 psig 5 to 50 psig 5 to 125 psig 15 to 250 psigPTF (0.3 to 3.5 bar) (0.3 to 8.6 bar) (1.0 to 17.2 bar) (0.3 to 3.5 bar) (0.3 to 8.6 bar) (1.0 to 17.2 bar) Catalog

1/4 11-002-021 11-002-019 11-002-023 11-002-015 11-002-013 11-002-017 NC-202

3/8 11-002-045 11-002-043 11-002-047 11-002-039 11-002-037 11-002-041 NC-202

1/2 11-002-069 11-002-067 11-002-071 11-002-063 11-002-061 11-002-065 NC-202

Options. Change model number as follows:Handwheel Adjustment: Add -8C to the end of

the desired model number.Screw Adjustment: Add -8B to the end of the

desired model number.Mounting Bracket assembled to unit: Add -1A to

the end the desired model number.Threaded bonnet for panel mounting –

With hand wheel adjustment: Add -2A to the end the desired model number.

With T-handle adjustment: Add -2B to the endthe desired model number.

With screw adjustment: Add -2C to the end the desired model number.

Nonrelieving Regulators: Contact NorgrenApplication Engineering.

Field AccessoriesMounting Bracket: 18-001-003Panel Mounting:

With T-Handle Adjustment: 18-003-003With Handwheel Adjustment: 18-003-001With Screw Adjustment: 18-003-005

Ordering Information

* Do not use these regulators to control pressures outside of those specified.

Page 19: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 19

General Purpose Regulators

SpecificationsFluid: Compressed airInlet Pressure: 400 psig (27.6 bar) maximum.Temperature Range: 0° to 175°F (-18°to 79°C)

with dewpoint less than air temperature below 35°F (2°C).

Gauge Ports: 1/8" PTF

Materials of ConstructionBody: ZincBonnet: AluminumValve: BrassValve Seat: BrassElastomers: NitrileBottom Plug—

1/4", 3/8" Ports: Brass1/2" Ports: Nylon

HDia.

A

GC

B

D

F – PanelHole Dia.

E – Max.PanelThickness

Panel Mounting Option

CT-Handle

& Hand-Port Screw wheelSize A B Adj. Adj. D E F G H J K L M N O P R

1/4", 3/8" 3.25 1.25 6.41 7.29 3.06 0.38 1.06 3.00 2.00 3.25 2.44 2.25 1.25 0.44 1.88 0.63 0.28(83) (32) (163) (185) (78) (10) (27) (76) (51) (83) (62) (57) (32) (11) (48) (16) (7)

1/2" 3.38 1.44 6.50 7.38 3.06 0.38 1.06 3.31 2.00 3.25 2.44 2.25 1.25 0.44 1.88 0.63 0.28(86) (37) (165) (187) (78) (10) (27) (84) (51) (83) (62) (57) (32) (11) (48) (16) (7)

Dimensions in Inches (mm)

J

OP

MN

R

L K

18-001-00311-002

Page 20: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

20 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Pilot and Precision Regulators

● Relief feature allows reduction of downstream pressure when the system is dead-ended.

● Constant bleed feature provides maximum sensitivityto system changes.

● 11-018 regulators provide precision regulation byuse of an integral pilot valve to control the mainvalve – a small change in the pilot valve positionresults in a large change in the main valve position.

● R38, R40, and R41 precision regulators feature highdiaphragm-to-valve area ratio.

● R40 and R41 are equipped with a nonrising adjustment knob. Mounting holes allow directmounting to a subbase.

● Stainless steel R38 units available. See NC-41 1.

Outlet Pressure1/4" PORTED Adjustment Average

MODELS Range* Flow Capacity** Repeatability†WITHOUT GAUGE Application psig (bar) scfm (dm3/s) psig (mbar) Catalog

11-018-146 Precision pressure control. 0.4 to 10 (0.03 to 0.69) 12 (5.7) 0.05 (3.5) —11-018-100 1.0 to 60 (0.1 to 4.1) 20 (9.4) 0.05 (3.5) NC-20711-018-110 3 to 150 (0.2 to 10.3) 20 (9.4) 0.16 (11.0) NC-207

R38-200-RNCA Instrumentation Series. 1 to 30 (0.1 to 2.0) 20 (9.4) 0.25 (17.3) NC-412R38-200-RNKA 4 to 100 (0.3 to 6.9) 20 (9.4) 0.25 (17.3) NC-412

R40-200-BNEA Conventional pilot regulator and 2 to 50 (0.1 to 3.5) 8 (3.8) 0.25 (17.3) NC-233R40-200-BNLA precision pressure control in low 5 to 125 (0.4 to 8.6) 8 (3.8) 0.25 (17.3) NC-233R40-200-BNSA flow and dead-end service. 10 to 250 (0.7 to 17.2) 8 (3.8) 0.25 (17.3) NC-233

11-104-001 Feedback pilot regulators. 5 to 100 (0.4 to 6.9) — — — — NIP-217R41-204-BNSA 50 to 250 (3.5 to 17.2) — — — — NC-230

Options. Change model number as follows:11-018 –

Screw adjustment:Change 11-018-100 to 11-018-101.Change 11-018-110 to 11-018-112.

R38 –Nonrelieving models. Use N in 7th position.Plastic adjusting knob. Add -7A to the end the

desired model number.R40 and R41 –

Nonbleed models: Use R in 7th position.ISO G ports: Use G in 10th position.ISO Rc ports: Use B in 10th position.

Field Accessories11-018 –

Tamper resistant cap for regulators withscrew adjustment): 639-02

R38 –Plastic adjusting knob: 655-97Mounting bracket with metal panel nut:

18-001-974Metal panel nut: 5988-01

R40 and R41–Mounting bracket with metal panel nut:

5203-06Metal panel nut: 5191-88Plastic panel nut: 5191-89Tamper resistant seal wire: 2117-01

Service Kits11-018 –

11-018-100: 2787-0111-018-110: 2787-0211-018-146: 2787-01Valve Seat Inserter Tool: 681-01

R38 –1 to 30 psig, relieving: 2787-344 to 100 psig, relieving: 2787-351 to 30 psig, nonrelieving: 2787-364 to 100 psig, nonrelieving: 2787-37

R40 and R41: 5945-41

Ordering Information

* Do not use these regulators to control pressures outside of those specified.** Flow capacity at 100 psig (6.9 bar) inlet pressure and 20 psig (1.4 bar) outlet pressure (10 psig outlet pressure for the 11-018-146).† Change in outlet pressure when system conditions change and then return to the original condition (i.e., system pressure turned off and on: flow increases and then

returns to the original flow).

Page 21: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 21

Pilot and Precision Regulators

SpecificationsFluid: Compressed airInlet Pressure –

11-018-100 & 11-018-146: 15 psig minimum to 150 psig maximum (1.0 to 10.3 bar)

11-018-110: 20 psig minimum to 200 psigmaximum (1.4 to 13.8 bar)

11-104: 10 psig minimum to 400 psigmaximum (0.7 to 27.6 bar)

R38: 290 psig (20 bar) maximumR40, R41: 10 psig minimum to 450 psig

maximum (0.7 to 31 bar)Temperature Range –

11-018: 0° to 160°F (-18° to 71°C)*11-104: 32° to 175°F (0° to 80°C)*R38, R40, R41: 0° to 175°F (-18° to 80°C)*

*With dewpoint less than air temperature below35°F (2°C).

Materials of Construction11-018 –

Body, Bonnet: ZincMain Valve: PolycarbonateMain Valve Seat: TeflonPilot Valve: Stainless SteelPilot Valve Seat: AluminumBottom Plug: BrassMain Diaphragm: NitrilePilot Diaphragm:

11-018-100 & 11-018-146: Beryllium Copper11-018-110: Nitrile

Elastomers: Nitrile, Neoprene, Polyurethane11-104 –

Body, Bonnet: ZincValve Seat: BrassValve Ball: Stainless SteelElastomers: Nitrile

R38 –Body, Bonnet: AluminumValve, Valve Seat: Stainless SteelElastomers: Nitrile

R40, R41 –Body, Bonnet, Valve Seat: AluminumValve: TeflonElastomers: Nitrile

E FMax. Pnl.Pnl. Hole

Type A B C D Thk. Dia. G H J K L M N O P R S T U

11-018 2.12 0.56 4.55 2.52 0.09 0.47 — — — — — — — — — — — — —(54) (14) (116) (64) (2) (12) — — — — — — — — — — — — —

11-104 3.13* 0.56 6.04 3.06 0.38 1.00 — — — — — — — — — — — — —(80) (14) (153) (78) (10) (25) — — — — — — — — — — — — —

R38 2.48 1.18 5.57 2.06 0.23 1.63 — — — — — 2.95 2.56 1.50 1.38 0.98 2.11 0.59 0.34

(63) (30) (141) (52) (6) (41) — — — — — (75) (65) (38) (35) (25) (54) (15) (9)

R40 & 2.00 1.14 5.24 2.05 0.19 1.89 1.63 1.57 2.47 2.01 1.14 2.50 2.75 1.50 1.50 1.00 1.50 0.66 0.28R41 (51) (29) (133) (52) (5) (48) (42) (40) (63) (51) (29) (64) (70) (38) (38) (25) (38) (17) (7)

Dimensions in Inches (mm)

A

C

DB

EF

A

CDB

E

F

OUT

J

K

L

A

H

C

B

G

DE

F

FeedbackPort (R41only)

1/16" PTF inlet port forsubbase mounting.

Tw

o 0

.27"

(7m

m)

Dia

.M

tg. H

ole

s0.

69(1

8)

M

ST

NP

ORU

11-018 Shown,11-104 Similar

R38 R40 and R41 18-001-974 (R38) Shown,5203-06 (R40) Similar

Main Ports –11-018: 1/4" PTF11-104: 1/4 PTFR38: 1/4" NPTR40, R41: 1/4" PTF

Gauge Ports –11-018: 1/4" PTF 11-104: NoneR38: 1/4" NPTR40, R41: None

Feedback Port –R40, R41, and 11-014 only: 1/8" PTF

Maximum bleed rate @ 50 psig (3.5 bar)outlet pressure –

11-018: 0.04 scfm (0.19 dm3/s)R38 (relieving models only): 0.005 scfm

(0.002 dm3/s)R40, R41: 0.25 scfm (0.12 dm3/s)

* Port to port dimension is 3.13 (80); body diameter is 3.25 (83).

Page 22: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

22 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Pilot Operated Regulators

● Ideal for systems that require pressure regulation at aninaccessible location or high flow .

● Standard regulators are relieving type with PTF threads.

● Balanced valve minimizes the effect of variations in inletpressure and its effect on outlet pressure.

● For general purpose applications, order a pilot operatedregulator below and an R07 or R72 regulator (see page16) for use as the pilot regulator .

● For precision applications, order a R18 or 1 1-042 pilotoperated regulator below and an R41 or 1 1-104 pilot regulator from page 20.

1/4" thru 2" Port Sizes

RELIEVING MODELSPort Without With

Type Size Application Gauge Gauge Catalog

R08 1/4" PTF Economy R08-221-RNXA R08-221-RGXA NC-2053/8" PTF R08-321-RNXA R08-321-RGXA1/2" PTF R08-421-RNXA R08-421-RGXA

11-008 1/2" NPTF Quick response 11-008-130 Contact Norgren Application Engineering NC-205

11-042 1/4" PTF High relief and quick response 11-042-001 11-042-004 NC-2343/8" PTF 11-042-002 11-042-0051/2" PTF 11-042-003 11-042-006

3/4" NPTF 11-042-007 11-042-0101" NPTF 11-042-008 11-042-011

1-1/4" NPTF 11-042-009 11-042-012

R24 1/4" PTF High relief R24-201-RNXA R24-201-RGXA NC-2453/8" PTF R24-301-RNXA R24-301-RGXA1/2" PTF R24-401-RNXA R24-401-RGXA3/4" PTF R24-601-RNXA R24-601-RGXA

1"PTF R24-801-RNXA R24-801-RGXA1-1/4" PTF R24-A01-RNXA R24-A01-RGXA

R18 1-1/2" PTF High relief and quick response R18-B00-RNXA R18-B00-RGXA NC-2302" PTF R18-C00-RNXA R18-C00-RGXA

Options. Change model number as follows:R08 –

ISO G threads: Use G in 10th position.ISO Rc threads: Use B in 10th position.

R18 –Nonrelieving models. Use N in 7th position.ISO G threads: Use G in 10th position.ISO Rc threads: Use B in 10th position.

R24 –ISO G threads: Use G in 10th position.ISO Rc threads: Use B in 10th position.

11-008 –Mounting bracket assembled to unit: Add -1Ato the end the model number.

11-042 –BSPP threads: Contact Norgren ApplicationEngineering

Field AccessoriesR08 –

Mounting Bracket: 3783-52R18 –

Exhaust Muffler: MB006AR24 –

Mounting Bracket: 18-001-996Plastic Mounting Nut: 2962-89Metal Mounting Nut: 2962-04

11-008 –Mounting Bracket: 18-001-003

11-042 –Exhaust Muffler: MB006A

Service KitsR08: 5298-14R18: 5945-40R24 –

1/4", 3/8", 1/2" ports: 5292-543/4", 1", 1-1/4" ports: 5292-55

11-008: 695-0111-042 –

1/4", 3/8", 1/2" ports: 4158-013/4", 1", 1-1/4" ports: 4158-02

Ordering Information

Page 23: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 23

Pilot Operated Compressed Air Regulators

SpecificationsFluid: Compressed airInlet Pressure (For best performance, inlet pres-

sure should be at least 20 psig (1.4 bar) high-er than the desired regulated pressure) –R08: 10 psig minimum to 300 psig maximum

(0.7 to 20.7 bar)R18: 10 psig minimum to 450 psig maximum

(0.7 to 31 bar)R24: 10 psig minimum to 300 psig maximum

(0.7 to 20.7 bar). 11-008 & 11-042: 10 psig minimum to 400

psig maximum (0.7 to 27.6 bar)Maximum Outlet Pressure: Up to 250 psig (17.3

bar). Outlet pressure is determined by thepilot regulator.

Temperature Range: 0° to 175°F (-18° to 79°C)Air supply must be dry enough to avoid iceformation at temperatures below 35°F (2°C).

Materials of ConstructionR08 –

Body, Bonnet: ZincValve: BrassBottom Plug: NylonElastomers: Nitrile

R18 –Body, Bonnet, Bottom Plug, Valve: AluminumElastomers: Nitrile

R24 –Body: ZincBottom plug: AcetalMain valve: BrassElastomers: Nitrile

11-008 –Body: ZincBonnet: AluminumValve: BrassBottom Plug: Nylon or AcetalElastomers: Nitrile

11-042 –Body: ZincBonnet: AluminumBottom Plug: AcetalValve: BrassElastomers: Nitrile

Dimensions in Inches (mm)

D

A

B

C

C

A

B

H

K

E

G

Port CL

FJ

L

J

OP

MN

R

L K

A

DB

C

A

D

C

B

H

G

F

L K

J

E

P

R N M

Gauge Ports: R08: 1/4 PTFR18: 1/4 PTFR24 –

1/4" with 1/4" main ports3/8" with 3/8" main ports1/2" with 1/2". 3/4", 1", 1-1/4" main ports

11-008: 1/8 PTF11-042 –

1/4" with 1/4" main ports3/8" with 3/8" main ports1/2" with 1/2". 3/4", 1", 1-1/4" main ports

Pilot port –R08: 1/8 NPTAll Others: 1/4" PTF

Exhaust Port –R18 & 11-042: 3/4 PTF

R08 R18

3783-52 (R08)

R24 11-042

A

C

DB

11-008

18-001-003 (11-008)18-001-996 (R24)

Port Size A B C D E F G H J K L M N O P R (Dia.)

R08 2.75 1.44 3.16 2.00 3.56 1.50 2.40 1.00 0.25 1.50 0.27 — — — — —(70) (37) (80) (51) (90) (38) (61) (25) (6) (38) (6) Dia. — — — — —

R18 5.98 3.56 7.24 — — — — — — — — — — — — —(152) (91) (184) — — — — — — — — — — — — —

R24 (1/4",3/8", and 2.09 1.42 4.40 2.70 1.81 2.63 1.63 0.63 1.00 0.63 0.31 0.63 0.50 — 1.13 0.221/2" Ports) (53) (36) (112) (69) (46) (67) (41) (16) (25) (16) (8) (16) (13) — (29) (6)

R24 (3/4", 1", and 3.65 1.79 5.00 2.70 1.81 2.63 1.63 0.63 1.00 0.63 0.31 0.63 0.50 — 1.13 0.221-1/4" Ports) (93) (46) (132) (69) (46) (67) (41) (16) (25) (16) (8) (16) (13) — (29) (6)

11-008 3.34 1.50 3.30 3.34 — — — — 3.25 2.44 2.25 1.25 0.44 1.88 0.63 0.27(85) (38) (84) (85) — — — — (83) (62) (57) (32) (11) (48) (16) (7)

11-042 (1/4", 3/8", and 2.71 1.48 5.07 4.16 — — — — — — — — — — — —1/2" Ports) (69) (38) (129) (106) — — — — — — — — — — — —

11-042 (3/4", 1", and 3.65 1.86 5.97 4.16 — — — — — — — — — — — —1-1/4" Ports) (93) (47) (152) (106) — — — — — — — — — — — —

Page 24: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

24 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

R24 Micro-T rol ® Special Purpose

● Unique design provides fast response and high-flowcapacity .

● Exceptionally high relief flow .

● Finger tip pressure adjustment

● Adjusting knob can be set in the field to stop atsome maximum or minimum pressure setting.

● Full flow gauge ports can be used as outlet ports orgauge ports, permitting manifolding or right anglepiping.

● Balanced valve minimizes effect of variations in inletpressure on outlet pressure.

RELIEVING MODELS WITH GAUGEOutlet Pressure Adjustment Range*

Port Size 5 to 30 psig 5 to 60 psig 10 to 125 psig 10 to 250 psigType PTF (0.34 to 2.1 bar) (0.34 to 4.1 bar) (0.7 to 8.6 bar) (0.7 to 17.2 bar) Catalog

R24 1/4 R24-200-RGCA R24-200-RGFA R24-200-RGLA R24-200-RGSA NC-2433/8 R24-300-RGCA R24-300-RGFA R24-300-RGLA R24-300-RGSA1/2 R24-400-RGCA R24-400-RGFA R24-400-RGLA R24-400-RGSA

R24 3/4 R24-600-RGCA R24-600-RGFA R24-600-RGLA R24-600-RGSA NC-2431 R24-800-RGCA R24-800-RGFA R24-800-RGLA R24-800-RGSA

1-1/4 R24-A00-RGCA R24-A00-RGFA R24-A00-RGLA R24-A00-RGSA

Options. Change model number as follows:Regulators without gauge: Use N in 8th position.ISO G threads: Use G in 10th position.ISO Rc threads: Use B in 10th position.

Field AccessoriesTamper resistant cap: 18-021-005Mounting bracket: 18-001-996Plastic mounting nut: 2962-89Metal mounting nut: 2962-04

Service KitsRegulators with 1/4", 3/8", 1/2" ports: 5292-52Regulators with 3/4", 1", 1-1/4" ports: 5292-53

Ordering Information

* Do not use these regulators to control pressures outside of the specified ranges.

Page 25: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 25

R24 Micro-T rol ® Special Purpose

SpecificationsFluid: Compressed airMaximum Inlet Pressure: 300 psig (20.7 bar)Temperature Range: 32° to 175°F (0° to 79°C)

with dewpoint of supply air less than air tem-perature below 35°F (2°C).

Gauge Ports –1/4" with 1/4" main ports.3/8" with 3/8" main ports.1/2" with 1/2", 3/4", 1", or 1-1/4" main ports.

Type: Piston, relieving.

Materials of ConstructionBody: ZincBottom Plug, Pilot Valve, & Relief Valve: AcetalAdjusting Screw & Main Valve: BrassElastomers: Nitrile

H

G

F

L K

J

E

P

R N M

Port Size A B C D E F G H J K L M N P R (Dia.)

1/4", 3/8", 1/2" 4.83 2.09 1.42 2.70 1.81 2.63 1.63 0.63 1.00 0.63 0.31 0.63 0.50 1.13 0.22(112) (53) (36) (69) (46) (67) (41) (16) (25) (16) (8) (16) (13) (29) (6)

3/4", 1", 1-1/4" 5.37 3.65 1.79 2.70 1.81 2.63 1.63 0.63 1.00 0.63 0.31 0.63 0.50 1.13 0.22(136) (93) (46) (69) (46) (67) (41) (16) (25) (16) (8) (16) (13) (29) (6)

Dimensions in Inches (mm)

B

CD

A

B

D

CA

R24 with 1/4", 3/8", 1/2" Ports R24 with 3/4", 1", 1-1/4" Ports 18-001-996

Panel mounting hole diameter(all port sizes):1.25" (32mm)

Maximum panel thickness (allport sizes): 0.10(3mm)

Page 26: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

26 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Water Regulators

● R06 – Low torque, nonrising pressure adjusting knobstandard. Screw adjustment with brass bonnetoptional.

● R43 – T-handle adjustment standard. Low torque,nonrising pressure adjusting knob optional. Full flowgauge ports can be used as auxiliary outlets.Balanced valve minimizes effects of inlet pressurevariations on outlet pressure.

● 11-009 – T-handle adjustment standard. Hand wheeland screw adjustments optional. Large diaphragmprovides provides quick response to changes in flowdemand.

1/8" thru 1" Port Sizes

NONRELIEVING MODELS WITH GAUGEOutlet Pressure Adjustment Range*

PortSize 1 to 10 psig 5 to 50 psig 5 to 100 psig 5 to 125 psig 15 to 250 psig

Type PTF (0.1 to 0.7 bar) (0.3 to 3.5 bar) (0.3 to 6.9 bar) (0.3 to 8.6 bar) (1.0 to 17.2 bar) Catalog

R06 1/8 R06-121-NGAA R06-121-NGEA R06-121-NGKA — — NC-2061/4 R06-221-NGAA R06-221-NGEA R06-221-NGKA — —

R43 1/4 — R43-201-NGEA — R43-201-NGLA R43-201-NGSA NC-2283/8 — R43-301-NGEA — R43-301-NGLA R43-301-NGSA1/2 — R43-406-NGEA — R43-406-NGLA R43-406-NGSA

11-009 3/4 — — — 11-009-073 — NC-2111 — — — 11-009-089 —

Options. Change model number as follows:R06 –

Without gauge: Use N in 8th position.Screw adjustment, brass bonnet: Use 2 in 6th

position.R43 –

Knob adjustment: Use 00 in 5th and 6th positions.

Without gauge: Use N in 8th position.ISO G ports: Use G in 10th position.ISO Rc ports: Use B in 10th position.

11-009 without gauge – Change 11-009-073 to 11-009-065.Change 11-009-089 to 11-009-081.

Field AccessoriesR06 –

Mounting bracket with plastic panel nut (usewith plastic bonnet): 18-025-003

Plastic panel nut: 2962-89Mounting bracket with brass panel nut (use

with brass bonnet): 18-001-020.Brass panel nut: 616-01Tamper resistant seal wire for adjusting

knob: 2117-01.R43 –

Mounting bracket: 5203-05Metal panel nut: 5191-88Plastic panel nut: 5191-89Tamper resistant seal wire for optional

adjusting knob: 2117-01.11-009 Regulator:

Handwheel adjustment: 1320-03Screw adjustment: 1095-05Mounting bracket: 18-001-028

Service KitsR06: 3407-01R43 –

1/4" & 3/8" Ports: 5298-031/2" Ports: 5298-10

11-009: 2436-03

Ordering Information

* Do not use these regulators to control pressures outside of the specified ranges.

Page 27: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 27

Water Regulators

SpecificationsFluid: Water or Compressed AirInlet Pressure: 400 psig (27.6 bar) maximumTemperature Range –

R06: 35° to 150°F (2° to 66°C)R43 & 11-009: 35° to 200°F (2° to 93°C)

Gauge Ports –R06 & 11-009: 1/8" PTFR43: 1/4" PTF

Materials of ConstructionR06 –

Body: BrassBonnet: Acetal (standard); Brass (optional)Valve: BrassValve Seat: AcetalElastomers: Nitrile

R43 –Body, Bottom Plug: BrassBonnet: AluminumValve: BrassElastomers: Nitrile

11-009 –Body: BrassBonnet: Aluminum and steelValve & Bottom Plug: BrassElastomers: Nitrile

J Dia.

H

A

B

CD

E

F – Max.PanelThickness

G – PanelHole Dia.

Type A B C D E F G H J K L M N O P R S T

R06 With 1.50 0.40 2.76 — 0.96 0.25 1.19 2.13 1.50 1.50 2.47 1.41 1.00 0.38 0.69 0.31 0.51 0.22Plastic Bonnet (38) (10) (70) — (24) (6) (30) (54) (38) (38) (63) (36) (25) (10) (18) (8) (13) (6)

R06 With 1.50 0.40 3.41 — 1.03 0.25 0.81 2.13 1.50 1.38 2.41 1.41 1.00 0.38 0.69 0.31 0.22 —Brass Bonnet (38) (10) (87) — (26) (6) (21) (54) (38) (35) (61) (36) (25) (10) (18) (8) (6) —

R43 – 1/4" & 2.76 1.52 4.86 5.75 1.21 0.19 1.89 2.78 2.00 2.50 2.75 1.50 1.50 1.00 1.50 0.66 0.28 —3/8" Ports (70) (39) (124) (146) (31) (5) (48) (71) (51) (64) (70) (38) (38) (25) (38) (17) (7) —

R43 – 3.34 1.59 5.01 5.90 1.28 0.19 1.89 2.85 2.00 2.50 2.75 1.50 1.50 1.00 1.50 0.66 0.28 —1/2" Ports (85) (41) (127) (150) (33) (5) (48) (72) (51) (64) (70) (38) (38) (25) (38) (17) (7) —

11-009 5.00 1.62 — 9.50 — — — 4.19 2.00 4.88 3.19 2.94 2.00 0.50 3.25 0.63 0.31 —(127) (41) — (241) — — — (106) (51) (124) (81) (75) (51) (13) (83) (16) (8) —

Dimensions in Inches (mm)

JDia.

A

HD

B

K

L

M

P

NRO

T

S

LN

M

K

O

P

S

R

K

PR

NO

S

M L

R43 Shown, R06 Similar 11-009 18-025-003 (R06 Plastic Bonnet)K

L

M

P

NRO

S

18-001-020 (R06 Brass Bonnet)5203-05 (R43)

18-001-028 (11-009)

Page 28: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

28 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

R83 Cylinder Gas Regulator

● Underwriters Laboratories, Inc. listed.

● Relieving or nonrelieving models.

● Regulator has two ports for high pressure (inlet andprimary gauge) and two ports for service (outlet andsecondary gauge).

● Diametrically opposite inlet ports allow manifolding.

RELIEVING AND NONRELIEVING MODELS WITHOUT GAUGEOutlet Pressure Adjustment Range*

2 to 50 psig 5 to 125 psig 10 to 175 psigType (0.14 to 3.4 bar) (0.34 to 8.6 bar) (0.7 to 12.1 bar) Catalog

Relieving R83-200-RNEA R83-200-RNLA R83-200-RNNA NC-232

Nonrelieving R83-200-NNEA R83-200-NNLA R83-200-NNNA

Field AccessoriesCylinder Valve Connectors –

Carbon dioxide service (0.830-14 RH internal thread, CGA No. 320): 18-008-002

Nitrogen service (0.906-14 RH external thread,CGA No. 580): 18-008-004

Check Valves –1/4 PTF male to 1/4" tube (45° flare):

16-009-0011/4 PTF male to 1/4 PTF female: 16-009-003

SpecificationsFluids: Carbon Dioxide, Water Pumped Air,

Nitrogen, Argon, Helium, Krypton, Neon,Xenon

Inlet Pressure: 3000 psig (206.9 bar) maxi-mum

Temperature Range: -40° to 140°F (-40° to60°C)

Ports: 1/4 PTF

Materials of ConstructionBody: BrassBonnet: ZincValve Assembly: Brass and Stainless SteelSeals: TeflonDiaphragm: Acetal and Nitrile

Dimensions in inches (mm).

Ordering Information

* Do not use these regulators to control pressures outside of the specified ranges.

30°

1.66 (42)

1.90 (48)

4.41

(11

2)

2.10 (53)

0.40

(10

)

Mounting Holes (2 Places)0.18 (4.6) dia. by 0.39 (10) deep.Use 10-32 thread forming screws.

Page 29: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 29

OptionsPulsation Dampener: Add -9D to the end the

model number.

SpecificationsFluid: Compressed Air or Inert GasesMaximum Pressure: 100% of full scale on gaugeMaximum Temperature: 175°F (79°C)Air Connection Location: Center back or bottom.Accuracy:

2% of full scale at midrange3% of full scale at other range

Materials of ConstructionCase: Steel or plasticCrystal: PlasticConnector: Brass

● Standard dual scale indicates pressure in psig andbar.

● An inches of water column scale with a 2-1/2 inchdiameter face is available.

● Back connection, bottom connection, or panelmounting.

● Optional pulsation dampener .

MODEL NUMBERSPANEL MOUNT**Back Connection

BACK CONNECTION BOTTOM CONNECTION 1/8 NPT Male &1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT 10-32 Female

Dial Range Gauge Diameter Gauge Diameter 1-1/2" Gauge 2" Gauge 1-1/2" Gaugepsig (bar) 1-1/2" 2" 2" 2-1/2" Diameter Diameter Diameter Catalog

0 to 15 (0 to 1) — — — — — 18-013-082 — NC-11010 to 30 (0 to 2) 18-013-214 18-013-201 18-013-207 — 18-013-224 18-013-030 5PG-306-000

0 to 60 (0 to 4) 18-013-211 18-013-202 18-013-208 — 18-013-225 18-013-083 5PG-312-0000 to 100 (0 to 7) — 18-013-203 — — — 18-013-084 5PG-320-000

0 to 160 (0 to 11) 18-013-212 18-013-204 18-013-209 — — 18-013-085 —0 to 300 (0 to 20) — 18-013-205 18-013-210 — — 18-013-086 —

0 to 400 (0 to 28) — 18-013-206 — — — — —0 to 2000 (0 to 138) — — — — — 18-013-244* —

0 to 3000 (0 to 205) — — — — — 18-013-087* —0 to 60" of water column — — — 18-013-221 — — —

Ordering Information

* Underwriters Laboratories Inc. Listed.**Requires 1.63" (41 mm) diameter panel hole.

Pressure Gauges

Page 30: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

30 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Filter/Regulator Operation

1 Adjusting Knob controls outlet pressure setting — clockwise rotationincreases and counterclockwise rotation decreases outlet pressuresetting.

2 Regulating Spring is compressed when adjusting knob is rotatedclockwise, which applies a downward force on top of flexiblediaphragm.

3 Flexible Diaphragm and Valve Pin move downward, forcing Valveoff the valve seat. Air flows past valve to downstream system.

4 Sensing Chamber — Pressure increases in downstream system andin the sensing chamber and applies an increasing upward force on thediaphragm bottom. The diaphragm, valve pin, and valve moveupward, compressing the regulating spring. Upward movement stopswhen the forces below the diaphragm balance the forces above thediaphragm. When there is no downstream flow demand, the balanceof forces occurs when the valve opens enough to compensate fordemand, thus maintaining the desired outlet pressure.

5 Louvers — Air entering the filter/regulator is guided into a swirlingpattern by the louvers. Coarse solid particles and liquids are forced tothe bowl wall by centrifugal force and drop to the bottom.

6 Filter Element removes most solid particles.

7 Baffle creates a quiet zone at the bottom of the bowl and prevents airturbulence from picking up liquids and returning the liquids to the airstream.

Graphic Symbols

Relieving, Automatic Drain

Relieving, Manual Drain

Nonrelieving, Automatic Drain

Nonrelieving, Manual Drain

Page 31: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 31

Filter/Regulator Operation

1

2

4

6

Valve Pin

7

5

3

Valve

Page 32: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

32 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

General Purpose Filter/Regulators1/8" thru 3/4" Port Sizes

● Can be disassembled for cleaning without removalfrom the air line.

● Choice of automatic or manual drain.

● Low torque, nonrising pressure adjustment knobprovides easy hand adjustment at any pressure.

● Balanced valve on B08, B72, and B74 unitsminimizes effect of variations in inlet pressure onoutlet pressure.

● Full flow gauge ports.

RELIEVING MODELS WITH GAUGEAutomatic Drain†† Manual Drain

Port Outlet Pressure Metal Bowl Transparent Metal Bowl TransparentSize Micron Adjustment Range * With Sight Polycarbonate With Sight Polycarbonate

Type PTF Size psig (bar) Glass Bowl Glass Bowl Catalog

B07 1/8 5 5 to 125 (0.3 to 8.6) B07-134-A1LA ** B07-102-A1LA B07-134-M1LA** B07-102-M1LA NC-4091/4 5 5 to 125 (0.3 to 8.6) B07-234-A1LA ** B07-202-A1LA B07-234-M1LA** B07-202-M1LA

B72 1/4 40 5 to 150 (0.3 to 10.4) B72G-2AK-SD3-RMG B72G-2AK-AL3-RMG B72G-2AK-QD3-RMG B72G-2AK-QT3-RMG NC-4193/8 40 5 to 150 (0.3 to 10.4) B72G-3AK-SD3-RMG B72G-3AK-AL3-RMG B72G-3AK-QD3-RMG B72G-3AK-QT3-RMG

B08 1/4 40 5 to 150 (0.3 to 10.4) B08-297-A3MA B08-221-A3MA B08-297-M3MA B08-221-M3MA NC-4103/8 40 5 to 150 (0.3 to 10.4) B08-397-A3MA B08-321-A3MA B08-397-M3MA B08-321-M3MA1/2 40 5 to 150 (0.3 to 10.4) B08-497-A3MA B08-421-A3MA B08-497-M3MA B08-421-M3MA

B74 3/8 40 5 to 150 (0.3 to 10.4) B74G-3AK-AD3-RMG B74G-3AK-AP3-RMG† B74G-3AK-QD3-RMG B74G-3AK-QP3-RMG† NC-4171/2 40 5 to 150 (0.3 to 10.4) B74G-4AK-AD3-RMG B74G-4AK-AP3-RMG† B74G-4AK-QD3-RMG B74G-4AK-QP3-RMG†3/4 40 5 to 150 (0.3 to 10.4) B74G-6AK-AD3-RMG B74G-6AK-AP3-RMG† B74G-6AK-QD3-RMG B74G-6AK-QP3-RMG†

Field AccessoriesMounting bracket –

B07: 18-025-003 †† B72: 4224-50B08: 5203-06 ††† B74: 4324-50

†† Includes plastic panel nut.††† Includes metal panel nut.Panel nut – Plastic Metal

B07 2962-89 2962-04B08 5191-89 5191-88B72 4248-89 –B74 – 4348-89

Tamper resistant kit for adjusting knob –B07: 18-001-092 B72: 4255-51B08: 2117-02 B74: 4355-51

Service KitsType Relieving NonrelievingB07 3820-02 3820-01B08 5304-06 5304-05B72 4383-500 4383-501B74 4383-700 4383-701

B07 kit includes 5-micron element. B08, B72,and B74 kits do not contain a filter element.

Ordering Information

* Do not use filter/regulators to control pressures outside the specified ranges.** The B07 metal bowl is not available with a sight glass.† The B74 includes a metal bowl guard with transparent bowls.

†† Semiautomatic drain on the B72 with metal bowl; diaphragm style spitterdrain on the B07.

B07 Options. Change model number as follows:

Transparent bowl, Relieving, No Gauge: Use 01in the 5th and 6th position.

Transparent bowl, Nonrelieving, No Gauge: Use03 in the 5th and 6th position.

Transparent bowl, Nonrelieving, With Gauge:Use 23 in the 5th and 6th position.

100µm Filter Element: Use 5 in the 8th position.ISO G Ports: Use G in 10th position.ISO Rc Ports: Use B in 10th position.

B72, B74 Options. Change modelnumber as follows:

ISO G Ports: Use G in the 6th position.ISO Rc Ports: Use B in the 6th position.T-Handle Adjustment: Use T in the 7th position.5µm Filter Element : Use 1 in the 10th position.Nonrelieving diaphragm: Use N in the 11th

position.No Gauge: Use N in the 13th position.

B08 Options. Change model number as follows:

Transparent bowl, Relieving, No Gauge: Use 00in the 5th and 6th position.

Transparent bowl, Nonrelieving, No Gauge: Use22 in the 5th and 6th position.

Transparent bowl, Nonrelieving, With Gauge:Use 23 in the 5th and 6th position.

Metal bowl, Sight Glass, Relieving, No Gauge:Use 96 in the 5th and 6th position.

Metal bowl, Sight Glass, Nonrelieving, NoGauge: Use 98 in the 5th and 6th position.

Metal bowl, Sight Glass, Nonrelieving, WithGauge: Use 99 in the 5th and 6th position.

5µm Filter Element: Use 1 in the 8th position.ISO G Ports: Use G in 10th position.ISO Rc Ports: Use B in 10th position.

Replacement ElementsType 5-Micron 40-MicronB07 5726-04 5726-05B08 3161-16 3161-18B72 5925-03 5925-02B74 4338-04 4338-05

Page 33: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 33

General Purpose Filter/Regulators

SpecificationsFluid: Compressed airMaximum Inlet Pressure:

Transparent Bowl: 150 psig (10.3 bar)Metal Bowl: 250 psig (17.2 bar)

Temperature Range:Transparent Bowl: 0° to 125°F (-18° to 52°C)*Metal Bowl:

B07, B72: 0° to 150°F (-18° to 66°C)*B08, B74: 0° to 175°F (-18° to 79°C)*

Gauge Ports:B07, B72: 1/8 PTFB08, B74: 1/4 PTF

Automatic Drain Connection –B07: 1/8" pipeB08, B74: 1/8" NPTFB72: ISO R1/8

Manual Drain Connection –B07: 1/8" pipeB08: NoneB72, B74: 7/16-24 for 1/4" tube nut and

ferruleB72 semiautomatic drain connection: Push on

5/16" ID flexible tube

* With dewpoint less than air temperature below35°F (2°C).

Materials of ConstructionBody –

B74: AluminumAll others: Zinc

Bonnet –B07, B72: AcetalB08: ZincB74: Aluminum

Valve: Brass/NitrileBowl –

Transparent: PolycarbonateMetal –

B74: AluminumAll others: Zinc

Element: Porous Polypropylene Elastomers: Neoprene & NitrileLiquid Level Indicator Lens (B72, B74):

Transparent nylon

Dimensions in Inches (mm)

A

C

B

JG – Panel Hole Dia.

F – Max. Panel Thickness

D

H

E

K

L

M

S R

O

T P

U

V

N

Port CL

Port CL

4224-50 (B72)4324-50 (B74)

K

L

M

P

NRO

T

S

18-025-003 (B07)

LN

M

K

O

P

S

R

5203-06 (B08)B74 Shown, Others Similar

NotesAutomatic drains operate when liquid

accumulates above a certain level. Spitter drainsoperate when a rapid change in flow occurs.Semiautomatic drains open when the filter isdepressurized.

Water vapor will pass through these units andcould condense into liquid form downstream asair temperature drops. Install a Norgren air dryerif water vapor could have a detrimental effect onthe application.

K L M N O P R S T U V

1.50 2.47 1.41 1.00 0.38 0.69 0.31 0.51 0.22 — —(38) (63) (36) (25) (10) (18) (8) (13) (6) — —

1.65 2.36 1.50 2.00 1.54 0.24 0.47 0.79 0.20 0.16 0.71(42) (60) (38) (51) (39) (6) (12) (20) (5) (4) (18)

2.50 2.75 1.50 1.50 1.00 1.50 0.66 0.28 — — —(64) (70) (38) (38) (25) (38) (17) (7) — — —

2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77(69) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20)

A JMax. H Auto. Man.

Type Dia. B C D E F G Knob T-Bar Drain Drain

B07 1.50 1.63 2.13 1.50 1.12 0.25 1.19 2.67 — 3.62 3.77(38) (41) (54) (38) (28) (6) (30) (68) — (92) (96)

B72 1.91 1.98 2.33 2.00 1.01 0.16 1.57 2.89 3.73 5.43 5.27*(48) (50) (59) (51) (26) (4) (40) (73) (95) (138) (134)

B08 2.68 2.75 2.50 2.00 1.18 0.19 1.89 3.68 — 5.70 6.08(68) (70) (64) (51) (30) (5) (48) (94) — (145) (154)

B74 2.89 3.15 3.66 2.00 1.24 0.25 2.06 4.98 5.95 6.35 6.95(74) (80) (93) (51) (31) (6) (52) (127) (151) (161) (177)

* 6.97" (177mm) for semiautomatic drain.

Page 34: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

34 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

B38 Instrument Filter/Regulator1/4" Port Size

● Highly accurate pressure regulation for flows up to20 scfm.

● Fast response to flow changes.

● Precision regulation is obtained by high ratio ofdiaphragm to valve area.

● Relieving models provide for reduction ofdownstream pressure when the system is dead-ended.

● Relieving models allow a small amount of air toescape to atmosphere, which helps providemaximum sensitivity to system changes.

● Offset drain allows mounting at an angle withoutcreating a water trap in bowl.

● Stainless steel B38 units avaiable. See NC-41 1.

Service KitsRegulator Section

Relieving, 1 to 30 psig range: 2787-34Relieving, 4 to 100 psig range: 2787-35Nonrelieving, 1 to 30 psig range: 2787-36Nonrelieving, 1 to 100 psig range: 2787-37

Filter Section: 2787-25

Outlet PressurePort Adjustment Average

Relieving Models Size Micron Range* Flow Capacity** Repeatability†(No Gauge) NPT Size psig (bar) scfm (dm3/s) psig (mbar) Catalog

B38-200-B2CA 1/4 25 1 to 30 (0.1 to 2.0) 20 (9.4) 0.25 (17.3) NC-412B38-200-B2KA 1/4 25 4 to 100 (0.3 to 6.9) 20 (9.4) 0.25 (17.3)

Options. Change model number as follows:Nonrelieving models: Use 1 in 6th position.Plastic hand wheel adjustment: Add -7A to end

of model number.

Field AccessoriesPlastic hand wheel adjustment: 655-97Aluminum mounting bracket and panel nut:

18-001-974Aluminum panel nut: 5988-01

Ordering Information

* Do not use filter/regulators to control pressures outside the specified ranges.** Flow capacity at 100 psig (6.9 bar) inlet pressure and 20 psig (1.4 bar) outlet pressure.† Change in outlet pressure when system conditions change and then return to the original condition (i. e., system pressure turned off and on;

flow increases and then returns to the original flow).

Page 35: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 35

B38 Instrument Filter/Regulator

SpecificationsFluid: Compressed airMaximum Inlet Pressure: 290 psig (20 bar)Temperature Range: 0° to 175°F (-18° to 80°C)

with dewpoint less than air temperature below35°F (2°C).

Main Ports: 1/4 NPTGauge Ports: 1/4 NPTRelief Port: UnthreadedMaximum bleed rate at 50 psig (3.5 bar) outlet

pressure (relieving models only): 0.005 scfm(0.002 dm3/s)

Materials of ConstructionBody, Bonnet, Bowl: AluminumValve Stem: Stainless SteelFilter Element: Porous PolyethyleneValve & Elastomers: Nitrile

Dimensions in inches (mm).

2.48(63)

1.63 (41) PanelHole Diameter

0.23

(6)

Max

.P

anel

th

ickn

ess

7.88

(20

0)

3.35

(85

)2.

06 (

52)

2.11 (54)

0.59 (15)

1.38

(35)

2.95 (75)

2.56

(65

)

1.50

(38)

0.98

(25)

0.34

(9)

18-001-974B38

Page 36: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

36 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Micro-Fog T ool Lubricators – For lubrication of one or more air driventools or devices.

Micro-Fog Lubricators inject a finely divided fog of oil into a flowing streamof compressed air to automatically provide the proper internal lubrication ofair operated tools and other devices. Oil is injected only when there is an airflow thru the lubricator. Micro-Fog density is controlled by the drip rateadjusting knob (1). Counterclockwise rotation of the knob increases andclockwise rotation decreases the Micro-Fog density.

The lubricator uses a flexible flow sensor (5) to control the flow of a smallamount of inlet air into the reservoir (9) thru the fog generator (3) inproportion to the air flow past the sensor. The high velocity air flowingthrough the generator aspirates oil up the siphon tube (8) into the sight-feeddome (2), where it drips downward through the needle valve orifice (4) intothe generator. The oil drops are then atomized and mixed with air flowingthru the generator into the reservoir. Most of the larger oil particles return tothe

Oil-Fog T ool Lubricators – For lubrication of a single air driven tool ordevice.

Oil-Fog Lubricators inject a fog of oil into a flowing stream of compressed airto automatically provide the proper internal lubrication of one air operatedtool or other device. Oil is injected only when there is an air flow through thelubricator.

The lubricator reservoir (5) is pressurized through the charge valve (4).Whenever there is an air flow thru the lubricator, the flexible flow sensor (3)in the lubricator throat creates a small pressure drop that is proportional tothe rate of air flow. The drop in pressure is sensed in the sight-feed dome(2) thru the nozzle passage (7). This establishes a pressure drop across theneedle valve orifice (6) which aspirates oil upward thru the siphon tube (9)into the sight-feed dome where it drips into the nozzle passage and theninto the lubricator throat. The adjusting knob (1) controls the oil drip rate.The oil drops are atomized by the air flowing through the lubricator throatand are carried downstream as oil-fog. All the drops visible in the sight-feed

Bearing Lubricators – For lubrication of machine bearings.

Bearing Lubricators inject a fog of oil into a flowing stream of compressed airto automatically provide the proper lubrication of bearings and gears inindustrial machines.

Air entering the lubricator flows thru the venturi (1) into the reservoir (2). Theair passing thru the venturi creates a pressure differential which aspirates oilfrom the reservoir up the siphon tube (3) to the sight-feed dome (4) where itdrips into the venturi. The air and oil action at the venturi creates a finelydivided oil aerosol in the upper part of the oil reservoir. Most of the larger

Lubricator Graphic Symbols

No Drain Manual Drain

Lubricator Operation

Page 37: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 37

dome are delivered downstream to the device being lubricated. The proportional controlafforded by the flow sensor provides a nearly constant oil-to-air density ratio over a widerange of air flows. The check ball (8) keeps the siphon tube full of oil during periods ofno air flow.

The charge valve (4) controls the rate of reservoir pressurization and allowsdepressurization for refilling without shutting off the air pressure. When the oil fill plug(not shown) is loosened, a bleed orifice is exposed which reduces the reservoirpressure. This pressure causes the charge valve (4) to close and restrict air flow intothe reservoir to eliminate blow-back when adding fresh oil. When the fill plug isreplaced, the reservoir repressurizes through the charge valve. The charge valve openswhen inlet pressure is reached. The charge valve is not used with bidirectionallubricators and lubricators having 2 or 5 gallon reservoirs. These lubricators cannot berefilled under pressure unless the lubricator is equipped with an optional quick-fill cap orremote fill device.

particles fall out, returning to the oil reservoir. The smaller particles (Micro-Fog)remain airborne and are carried thru the air line to points of lubrication. Only a smallportion of the drops visible in the sight-feed dome are delivered downstream to thedevice being lubricated.

Bearing Lubricators have a lower air flow capacity, higher pressure drop, andproduce denser Micro-Fog than Tool Lubricators.

7

1

2

8

63

4

5

9

9

3

8

4

6

7

1

2

5

2

1

4

3

reservoir. The finer particles (Micro-Fog) remain airborne and are carried thru thepassage (6) into the downstream system. Only a small portion of the drops visible inthe sight-feed dome are delivered downstream to the device being lubricated. Theproportionate control afforded by the flow sensor provides a nearly constant oil-to-airdensity ratio over a wide range of air flows. The check ball (7) keeps the siphon tubefull during periods of no flow.

When pressurized, Micro-Fog Lubricators can only be filled with oil when equippedwith an optional quick-fill cap or remote fill device.

Lubricator Operation

Page 38: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

38 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Micro-Fog ® Tool Lubricators1/8" thru 1-1/2" Port Sizes

● Flow sensor design provides a nearly constant oil/airratio over a wide air flow range.

● Tamper resistant device can be installed on oil-feedadjustment to resist unauthorized adjustment.

● All around (360 °) visibility of the sight-feed domesimplifies installation and adjustment.

● Optional 1-quart reservoir available on the L74. Referto page 42.

● The optional 2- and 5-gallon reservoirs used on theL17 lubricator are rated to ASME Pressure V esselCode, Section VIII. Refer to page 42.

Field AccessoriesWall Mounting Brackets –

L07 –Bracket & plastic panel nut: 18-025-003Plastic panel nut: 2962-89

L08: 3783-52L17 (3/4" & 1" ports): 6212-50L17 (1-1/4" & 1-1/2" ports): 6212-51L72: 4224-50L74 with standard 7-ounce reservoir: 4324-50

Tamper resistant device for standard sight-feeddome – L07, L08, L17, L74: 2117-01L72: 4050-89

Options. Change model number as follows:Pyrex Sight-Feed Dome –

L08: Add -8W to end of desired model number.

L17: Add -8N to end of desired model number.

L72 and L74: Use P in 10th positionQuick Fill Cap –

L08: Add -2M to end of desired model number.

L17: Add -2L to end of desired model number.

L74: Use Q in 10th positionFill Plug with 1/8" Tapped Hole –

L17: Add -8L to end of desired model number.

ISO G Ports –L07, L08, L17: Use G in the 10th position.L72, L74: Use G in 6th position.

ISO Rc Ports –L07, L08, L17: Use B in the 10th position.L72, L74: Use B in 6th position.

Service KitsL07: 3795-03L08: 5324-02L17: 5771-02L72: 4382-500L74: 4382-700

NoteMicro-Fog Lubricators must not be locateddownstream from frequently cycling directionalcontrol valves. Bidirectional Oil-Fog Lubricatorsmust be used under such conditions.

Ordering Information

* At 100 psig (6.9 bar) inlet pressure and 5 psid.** L74 lubricators include a metal guard with transparent reservoirs.

MODEL NUMBERSPort Recommended Std.Size Flow Range * Rsvr. Metal Reservoir Transparent Polycarbonate

Type PTF scfm (dm3/s) Size With Drain and Sight Glass Reservoir With Drain Catalog

L07 1/8 0.5 to 10 (0.2 to 4.7) 1-oz — L07-100-MPAA NC-3051/4 0.5 to 10 (0.2 to 4.7) 1-oz — L07-200-MPAA

L72M 1/4 2.0 to 36 (0.94 to 17.0) 1.9-oz L72M-2AP-QDN L72M-2AP-QTN NC-3483/8 2.0 to 36 (0.94 to 17.0) 1.9-oz L72M-3AP-QDN L72M-3AP-QTN

L08 1/4 2.5 to 20 (1.2 to 9.5) 1/3-pt L08-200-MPDA L08-200-MPCA NC-3603/8 4.0 to 40 (1.9 to 19.0) 1/3-pt L08-300-MPDA L08-300-MPCA1/2 4.0 to 40 (1.9 t0 19.0) 1/3-pt L08-400-MPDA L08-400-MPCA

L74M 3/8 2.5 to 40 (1.2 to 19.0) 7-oz L74M-3AP-QDN L74M-3AP-QPN** NC-3651/2 3.5 to 100 (1.7 to 47.0) 7-oz L74M-4AP-QDN L74M-4AP-QPN**3/4 3.5 to 100 (1.7 to 47.0) 7-oz L74M-6AP-QDN L74M-6AP-QPN**

L17 3/4 8.0 to 160 (3.8 to 75.5) 1-qt. L17-600-MPDA — NC-3601 8.0 to 275 (3.8 to 129.8) 1-qt. L17-800-MPDA —

1-1/4 8.0 to 275 (3.8 to 129.8) 1-qt. L17-A00-MPDA —1-1/2 8.0 to 275 (3.8 to 129.8) 1-qt. L17-B00-MPDA —

Page 39: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 39

Micro-Fog T ool Lubricators

SpecificationsMaximum Inlet Pressure –

Transparent Bowl: 150 psig (10.3 bar)Metal Bowl: 250 psig (17.2 bar)

Maximum Temperature –Transparent Bowl: 125°F (52°C)Metal Bowl –

L72: 150°F (65°C)All Others: 175°F (79°C)

Recommended Lubricants: Use a misting typeoil rated 50 to 200 SSU (ISO Grade 7 to 46)at 100°F (38°C). The oils used must becompatible with materials of construction.Contact your lubricant supplier and the builderof the equipment to be lubricated to obtainspecific lubricant recommendations.

L72, L74 manual drain connection: 7/16-24 UNSmale (for 1/4” tube nut and ferrule).

Materials of ConstructionBody –

L07, L08, L72: ZincL17, L74: Aluminum

Reservoir –Transparent: PolycarbonateMetal –

L07, L08, L72: ZincL17, L74: Aluminum

Reservoir Sight Glass –L08, L17: PyrexL72, L74: Transparent Nylon

Sight-Feed Dome –Standard Dome: Transparent NylonOptional Dome: Pyrex & Aluminum

Elastomers: Neoprene and Nitrile (Geolast®also used on the L72)

L08, L72, L74 Micro-Fog Capsule: Red Acetal

A

BC

D

E

F

G

KHL

J

N

M

18-025-003 (L07)

H

K

E

G

Port CL

FJ

L

K

JE

FG

Port CL

H

E

F

G

M L

J

N K

PR

H

Port CL

Port CL

L74 Shown, Others Similar 3783-52 (L08) 6212-50 & 6212-51 (L17)4224-50 (L72)4324-50 (L74)

B CMax. Std. Pyrex

Type A Dia. Dome Dome D E F G H J K L M N P R

L07 1.63 1.45 1.98 — 3.87 1.50 2.47 1.41 1.00 0.38 0.69 0.31 0.51 0.22 — —(41) (37) (50) — (98) (38) (63) (36) (25) (10) (18) (8) (13) (6) — —

L72M 1.98 1.91 1.63 2.51 5.27 1.65 2.36 1.50 2.00 1.54 0.24 0.47 0.70 0.20 0.16 0.71(50) (48) (41) (64) (134) (42) (60) (38) (51) (39) (6) (12) (20) (5) (4) (18)

L08 2.75 2.68 2.03 2.74 6.08 3.56 1.50 2.40 1.00 0.25 1.50 0.27 (6) — — — —(70) (68) (52) (70) (154) (90) (38) (61) (25) (6) (38) Dia. — — — —

L74M 3.15 2.89 2.12 2.69 6.95 2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77(80) (74) (53) (68) (177) (62) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20)

L17 4.50 5.52 2.22 2.92 10.24 5.13 1.69 3.00 0.34 (9) 3.91 1.00 — — — — —(114) (140) (56) (74) (260) (130) (43) (76) Dia. (81) (25) — — — — —

Page 40: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

40 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

● Flow sensor design (except 10-028 and 10-076) provides a nearly constant oil/air ratio over a wide airflow range.

● Tamper resistant device can be installed on oil-feedadjustment to resist unauthorized adjustment.

● All around (360 °) visibility of the sight-feed domesimplifies installation and adjustment.

● Optional 1-quart reservoir available on the L74. Referto page 42.

● The optional 2- and 5-gallon reservoirs used on theL17 lubricator are rated to ASME Pressure V esselCode, Section VIII. Refer to page 42.

● Can be filled under pressure, except for optionalbidirectional models and models with 2- and 5-gallonreservoirs.

Ordering Information

*At 100 psig (6.9 bar) inlet pressure and 5 psid.**L74 Lubricators include a metal guard with transparent reservoirs

Oil-Fog T ool Lubricators1/8" thru 2" Port Sizes

Options. Change model number as follows:Pyrex Sight-Feed Dome –

L08, 10-028: Add -8W to end of desired modelnumber.

L17: Add -8N to end of desired model number.

L72 and L74: Use P in 10th positionQuick Fill Cap –

L08: Add -2M to end of desired modelnumber.

L17: Add -2L to end of desired model number.

L74: Use Q in 10th position10-028: Add -2J to end of desired model

number.Fill Plug with 1/8" Tapped Hole –

L17: Add -8L to end of desired model number.

ISO G Ports –L08, L17: Use G in the 10th position.L72, L74: Use G in 6th position.

ISO Rc Ports –L08, L17: Use B in the 10th position.L72, L74: Use B in 6th position.

Bidirectional Lubricators –L17: Use E in 8th positionL74: Use E in 7th position

Field AccessoriesWall Mounting Brackets –

L08: 3783-52L17 (3/4" & 1" ports): 6212-50L17 (1-1/4" & 1-1/2" ports): 6212-51L72: 4224-50L74 with standard 7-ounce reservoir: 4324-5010-028 & 10-076 with 2-gal. rsvr: 18-001-05610-028 & 10-076 with 5-gal. rsvr: 18-001-039

Tamper resistant device for standard sight-feeddome – L08, L17, L74, 10-028: 2117-01L72: 4050-8910-076: 18-004-006

Service KitsL08: 5324-02L17: 5771-02L72: 4382-500L74: 4382-70010-076: 3035-02

NoteDo not use L08, L17, L72, L74 lubricators, and the 10-028 lubricator with 1 or 2 quart reservoirs, downstreamof frequently cycling directional control valves. Use theoptional bidirectional Oil–Fog Lubricator for suchconditions.

MODEL NUMBERSPort Recommended StdSize Flow Range * Rsvr. Metal Reservoir Transparent Reservoir

Type PTF scfm (dm3/s) Size With Drain and Sight Glass With Drain Catalog

L72C 1/4 1.0 to 36 (0.47 to 17.0) 1.9-oz L72C-2AP-QDN L72C-2AP-QTN NC-3483/8 1.0 to 36 (0.47 to 17.0) 1.9-oz. L72C-3AP-QDN L72C-3AP-QTN

L08 1/4 2.5 to 20 (1.2 to 9.0) 1/3-pt. L08-200-OPDA L08-200-OPCA NC-3613/8 4.0 to 40 (1.9 to 19.0) 1/3-pt. L08-300-OPDA L08-300-OPCA1/2 4.0 to 40 (1.9 to 19.0) 1/3-pt. L08-400-OPDA L08-400-OPCA

L74C 3/8 2.5 to 40 (1.2 to 19.0) 7-oz L74C-3AP-QDN L74C-3AP-QPN** NC-3651/2 3.5 to 100 (1.7 to 47.0) 7-oz L74C-4AP-QDN L74C-4AP-QPN**3/4 3.5 to 100 (1.7 to 47.0) 7-oz L74C-6AP-QDN L74C-6AP-QPN**

L17 3/4 8.0 to 160 (3.8 to 75.5) 1-qt. L17-600-OPDA — NC-3611 8.0 to 275 (3.8 to 129.8) 1-qt. L17-800-OPDA —

1-1/4 8.0 to 275 (3.8 to 129.8) 1-qt. L17-A00-OPDA —1-1/2 8.0 to 275 (3.8 to 129.8) 1-qt. L17-B00-OPDA —

10-028 1-1/2 110 to 590 (52 to 278) 1-qt. 10-028-045 — NC-3641-1/2 110 to 590 (52 to 278) 2-qt. 10-028-046 —1-1/2 110 to 590 (52 to 278) 2-gal. 10-028-047 —1-1/2 110 to 590 (52 to 278) 5-gal. 10-028-048 —

10-076 2 250 to 1000 (118 to 471.9) 2-gal. 10-076-004 — NC -3032 250 to 1000 (118 to 471.9) 5-gal. 10-076-005 —

Page 41: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 41

Oil Fog T ool Lubricators

SpecificationsMaximum Inlet Pressure –

Transparent Bowl: 150 psig (10.3 bar)Metal Bowl: 250 psig (17.2 bar)

Maximum Temperature –Transparent Bowl: 125°F (52°C)Metal Bowl –

L72: 150°F (65°C)All Others: 175°F (79°C)

Recommended Lubricants: Use a misting typeoil rated 50 to 200 SSU (ISO Grade 7 to 46)at 100°F (38°C). The oils used must becompatible with materials of construction.Contact your lubricant supplier and the builderof the equipment to be lubricated to obtainspecific lubricant recommendations.

Reservoir Sight Glass –L08, L17, 10-028, 10-076: PyrexL72, L74: Transparent Nylon

Sight-Feed Dome (not used on 10-076) –Standard Dome: Transparent NylonOptional Dome: Pyrex & Aluminum

Sight-Feed Glass (only on 10-076): PyrexElastomers –

L08, L17, L74, 10-028: Neoprene and NitrileL72: Neoprene, Nitrile, Geolast®10-026: Nitrile

Throttling Disc on 10-076: FeltL08, L72, L74 Oil-Fog Capsule: Green Acetal

A

BC

D

H

KE

G

Port CL

FJ

L

K

JE

FG

Port CL

H

E

F

G

M L

J

N K

PR

H

Port CL

Port CL

L74 Shown, L08, L17,L72 Similar

3783-52 (L08) 6212-50 & 6212-51 (L17)4224-50 (L72)4324-50 (L74)

L72, L74 manual drain connection: 7/16-24 UNSmale (for 1/4” tube nut and ferrule).

Materials of ConstructionBody –

L08, L72: ZincL17, L74, 10-028, 10-076: Aluminum

Reservoir –Transparent: PolycarbonateMetal –

L08, L72: ZincL17, L74: Aluminum10-028, 10-076: Steel

A

B

E

C

D

10-076 Shown, 10-028 Similar

B CMax. Std. Pyrex

Type A Dia. Dome Dome D E F G H J K L M N P RL72C 1.98 1.91 1.63 2.51 5.27 1.65 2.36 1.50 2.00 1.54 0.24 0.47 0.70 0.20 0.16 0.71

(50) (48) (41) (64) (134) (42) (60) (38) (51) (39) (6) (12) (20) (5) (4) (18)

L08 2.75 2.68 2.03 2.74 6.08 3.56 1.50 2.40 1.00 0.25 1.50 0.27 (6) — — — —(70) (68) (52) (70) (154) (90) (38) (61) (25) (6) (38) Dia. — — — —

L74C 3.15 2.89 2.12 2.69 6.95 2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77(80) (74) (53) (68) (177) (62) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20)

L17 4.50 5.52 2.22 2.92 10.24 5.13 1.69 3.00 0.34 (9) 3.91 1.00 — — — — —(114) (140) (56) (74) (260) (130) (43) (76) Dia. (81) (25) — — — — —

10-028 5.25 4.06 2.44 2.91 10.75 4.94 — — — — — — — — — —(1-qt) (133) (103) (62) (74) (273) (125) — — — — — — — — — —

10-028 5.25 4.63 2.44 2.91 13.00 5.38 — — — — — — — — — —(2-qt) (133) (118) (62) (74) (330) (137) — — — — — — — — — —

10-028 5.25 6.25 2.44 2.91 21.16 7.44 — — — — — — — — — —(2-gal) (133) (159) (62) (74) (538) (189) — — — — — — — — — —

10-028 5.25 10.25 2.44 2.91 21.44 11.44 — — — — — — — — — —(5-gal) (133) (260) (62) (74) (545) (291) — — — — — — — — — —

10-076 5.25 6.25 — 5.13 25.44 7.44 — — — — — — — — — —(2-gal) (133) (159) — (130) (646) (189) — — — — — — — — — —

10-076 5.25 10.25 — 5.13 28.69 11.44 — — — — — — — — — —(5-gal) (133) (260) — (130) (729) (291) — — — — — — — — — —

Page 42: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

42 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

L17 and L74 lubricators with Large Reservoirs 3/8" thru 1-1/2" Port Sizes

● Flow sensor design provides a nearly constant oil/airratio over a wide air flow range.

● Simple oil-feed adjustment. T amper resistant devicecan be installed to resist unauthorized adjustment.

● All around (360 °) visibility of the sight-feed domesimplifies installation and adjustment.

● The 2- and 5-gallon reservoirs used on the L17lubricator are rated to ASME Pressure V essel Code,Section VIII.

● Standard L74 Oil-Fog can be filled under pressure,(optional bidirectional model cannot).

MICRO-FOG MODEL NUMBERS *PortSize

Type PTF 1-Qt. 2-Qt. 2-Gal. 5-Gal. Catalog

L74 3/8 L74M-3AP-QAN — — — NC-3651/2 L74M-4AP-QAN — — —3/4 L74M-6AP-QAN — — —

L17 3/4 Refer to L17-600-MPHA L17-600-MPJA L17-600-MPKA NC-3601 Preceding L17-800-MPHA L17-800-MPJA L17-800-MPKA &

1-1/4 Pages L17-A00-MPHA L17-A00-MPJA L17-A00-MPKA NC-3611-1/2 L17-B00-MPHA L17-B00-MPJA L17-B00-MPKA

Ordering Information - See page 40 for Recommended Flow Range.

*For L17 Oil-Fog lubricators, use O in 7th position. For L74 Oil Fog lubricators, use C in 4th position.

Options. Change model number as follows:Pyrex Sight-Feed Dome –

L17: Add -8N to end of desired model number.

L74: Use P in 10th positionQuick Fill Cap –

L17: Add -2L to end of desired model number.

L74: Use Q in 10th positionFill Plug with 1/8" Tapped Hole –

L17: Add -8L to end of desired model number.

ISO G Ports –L17: Use G in the 10th position.L74: Use G in 6th position.

ISO Rc Ports –L17: Use B in the 10th position.L74: Use B in 6th position.

Bidirectional Lubricators (Oil-Fog only) –L17: Use E in 8th positionL74: Use E in 7th position

Field AccessoriesWall Mounting Brackets –

L17 –2-qt rsvr, 3/4" & 1" ports: 6212-502-qt rsvr, 1-1/4" & 1-1/2" ports: 6212-512-gal reservoir strap: 18-001-0565-gal reservoir strap: 18-001-039

L74 with 1-qt reservoir: 4324-51Tamper resistant device for standard sight-feed

dome: 2117-01

Service KitsL17: 5771-02L74: 4382-700

NoteModels listed in order table must not be locateddownstream from frequently cycling directionalcontrol valves. Use optional bidirectionalOil–Fog Lubricator for such conditions.

Page 43: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 43

L17 and L74 Lubricators with Large Reservoirs

SpecificationsMaximum Inlet Pressure: 250 psig (17.2 bar)Maximum Temperature: 175°F (79°C)Recommended Lubricants: Use a misting type

oil rated 50 to 200 SSU (ISO Grade 7 to 46)at 100°F (38°C). The oils used must becompatible with materials of construction.Contact your lubricant supplier and the builderof the equipment to be lubricated to obtainspecific lubricant recommendations.

L74 manual drain connection: 7/16-24 UNSmale (for 1/4” tube nut and ferrule).

Materials of ConstructionBody: AluminumReservoir –

L17: Steel*L74: Aluminum

Reservoir Sight Glass –L17: PyrexL74: Transparent Nylon

Sight-Feed Dome –Standard Dome: Transparent NylonOptional Dome: Pyrex & Aluminum

Elastomers: Neoprene and Nitrile

* 2- and 5-gallon reservoirs are rated to ASMEPressure Vessel Code, Section VIII.

A

B

S

CD

A

.

B

SD

C

A

L74L17

E

F

G

M L

J

N K

PR

H

Port CL

Port CL

4324-51 (L74)

K

JE

FG

Port CL

H

6212-50 & 6212-51 (L17)

Dimensions in inches (mm).B C

Max. Std. Pyrex

Type A Dia. Dome Dome D E F G H J K L M N P R S

L74 3.15 4.32 2.12 2.69 11.90 2.72 4.29 3.17 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77 2.40(1-Qt) (80) (110) (53) (68) (303) (62) (109) (81) (61) (50) (6) (25) (37) (4) (5) (20) (61)

L17 4.50 4.63 2.22 2.92 13.13 5.13 1.69 3.00 0.34 (9) 3.91 1.00 — — — — — 5.38(2-Qt) (114) (118) (56) (74) (333) (130) (43) (76) Dia. (81) (25) — — — — — (137)L17 4.50 6.25 2.22 2.92 21.19 — — — — — — — — — — — 7.44

(2-Gal) (114) (159) (56) (74) (538) — — — — — — — — — — — (189)L17 4.50 10.25 2.22 2.92 24.19 — — — — — — — — — — — 11.44

(5-Gal) (114) (260) (56) (74) (614) — — — — — — — — — — — (291)

Page 44: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

44 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Machine Bearing Lubricators1/4" Ports

● Centralized bearing lubricator system does notrequire ready access to the lubrication points.Controls can easily be installed to start-up andshutdown the lubricator with the machine. No returnlines to the lubricator are required.

● Less oil consumption – Micro-Fog Lubricatordelivers a fog of oil to the application points.Bearing surfaces are coated with a thin oil film (themost effective lubrication form). Daily oilconsumption can often be reduced from quarts tofluid ounces.

● Longer bearing life – air carrying the lubricantpasses through the bearing housing, reducingbearing temperature and contamination.

● Lubricator system can be interlocked with machineoperation or an alarm system.

● Refer to Norgren Publication NT -1 for system design,bearing-inch ratings, and reclassifier selection.

Options. Change model number as follows:Mounting Bracket attached to 1/2-pint, 1-quart,

or 2-quart reservoir: Add -1B to end of desiredmodel number

Quick Fill Cap (Straight): Add -2H to end ofdesired model number

Pyrex Sight-Feed Dome: Add -7C to end ofdesired model number

Liquid Level Control –1-Quart Reservoir: Add -3C to end of desired

model number2-Quart Reservoir: Add -3A to end of desired

model number2-Gallon Reservoir: Add -3D to end of desired

model number5-Gallon Reservoir: Add -3E to end of desired

model number

Field AccessoriesMounting Bracket –

1/2-pint, 1-quart, 2-quart reservoirs:18-001-008

Mounting Strap –2-gallon reservoir: 18-001-0565-gallon reservoir: 18-001-039

Streamline Wyes –1/4" pipe size: 18-006-0161/2" pipe size: 18-006-0193/4" pipe size: 18-006-021

Aerosol Distributors –4-Port: 18-005-0018-Port: 18-005-002

Solenoid Valves –110 Volt: A0007F-115V220 Volt: A0007F-220V

Manifold pressure gauge (60" of water columnand 146 cm of water column): 18-013-221

Service KitsElastomers: 714-01

Ordering Information

*Equipped with factory-installed remote fill device.

Nominal Bearing Air Consumption Applied PressureMODEL NUMBERS Port Size Reservoir Size Inches scfm (dm3/s) psig (bar) Catalog

10-015-100* 1/4" 1/2-Pint 8 to 32 1.1 to 4.5 (0.5 to 2.1) 6 to 40 (0.4 to 2.8) NC-33810-015-002 1/4" 1/2-Pint 8 to 32 1.1 to 4.5 (0.5 to 2.1) 6 to 40 (0.4 to 2.8)

10-015-004 1/4" 1-Quart 8 to 32 1.1 to 4.5 (0.5 to 2.1) 6 to 40 (0.4 to 2.8) NC-33810-015-005 1/4" 2-Quart 8 to 32 1.1 to 4.5 (0.5 to 2.1) 6 to 40 (0.4 to 2.8)

10-065-006 1/4" 2-Gallon 8 to 32 1.1 to 4.5 (0.5 to 2.1) 6 to 40 (0.4 to 2.8) NC-33810-065-007 1/4" 5-Gallon 8 to 32 1.1 to 4.5 (0.5 to 2.1) 6 to 40 (0.4 to 2.8)

Page 45: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 45

Machine Bearing Lubricators

SpecificationsMaximum Inlet Pressure:

Transparent Bowl: 150 psig (10.3 bar)Metal Bowl: 250 psig (17.2 bar)

Maximum Temperature:Transparent Bowl: 125°F (52°C)Metal Bowl: 175°F (79°C)

Port Size: 1/4" PTF Inlet & OutletRecommended Lubricants: Use a misting type oil

rated below 700 SSU (ISO Grade 150) at100°F (38°C). The oils used must becompatible with materials of construction.Contact your lubricant supplier and the builderof the equipment to be lubricated to obtainspecific lubricant recommendations.

Materials of ConstructionBody: ZincReservoir:

1/2-Pt.: Transparent Polycarbonate1-Qt., 2-Qt., 2-Gal., 5-Gal.: Steel with PyrexSight Glass

Sight-Feed Dome:Standard: PolycarbonateOptional: Pyrex & Brass

Elastomers: Neoprene and Nitrile

Dimensions in inches (mm).

A

BC

DD

10-015 with 1/2 Pint Reservoir

A

BE

CD

C

D

BE

A3.25 (83)

1.88 (48)

0.95 (24)

0.33

(8)

1.75

(45)

2.25

(57

)

2.13

(54

)

2.94

(75

)

10-015 with 1 & 2 Quart Reservoir 10-065 with 2 & 5 Gallon Reservoir 18-001-008 (for 1/2 Pint, 1 Quart & 2Quart Reservoirs)

Reservoir PortSize Size A B C D E

1/2-Pint 1/4" 3.38 (86) 3.75 (95) 1.88 (48) 7.38 (187) —

1-Quart 1/4" 3.38 (86) 4.06 (103) 2.00 (51) 9.56 (243) 1.30 (33)

2-Quart 1/4" 3.38 (86) 4.63 (118) 2.00 (51) 12.31 (313) 1.30 (33)

2-Gallon 1/4" 3.38 (86) 6.25 (159) 1.81 (46) 19.68 (500) 1.30 (33)

5-Gallon 1/4" 3.38 (86) 10.25 (260) 1.81 (46) 22.94 (583) 1.56 (40)

Page 46: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

46 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Filter/Regulator-Lubricator

Operation is the same as described in the previous filter/regulator andlubricator sections.

Available with Micro-Fog or Oil-Fog Lubricators. An Oil-Fog unit should beprovided to each device requiring lubrication. Use Micro-Fog units insystems containing complex piping or multiple points of lubrication.

NOTEMicro-Fog and Oil-Fog Combination Units must not be located downstreamof frequently cycling directional control valves. Bidirectional Oil-FogLubricators should be used under such conditions.

Filter-Regulator-Lubricator

Operation is the same as described in the previous filter, regulator, andlubricator sections.

Available with Micro-Fog or Oil-Fog Lubricators. An Oil-Fog unit should beprovided for each device requiring lubrication. Use Micro-Fog units insystems containing complex piping or multiple points of lubrication.

NOTEMicro-Fog and Oil-Fog Combination Units must not be located downstreamof frequently cycling directional control valves. Bidirectional Oil-FogLubricators should be used under such conditions.

Filter-Lubricator

Operation is the same as described in the previous filter and lubricatorsections.

Available with Micro-Fog or Oil-Fog Lubricators. An Oil-Fog unit should beprovided for each device requiring lubrication. Use Micro-Fog units insystems containing complex piping or multiple points of lubrication.

NOTEMicro-Fog and Oil-Fog Combination Units must not be located downstreamof frequently cycling directional control valves. Bidirectional Oil-FogLubricators should be used under such conditions.

Combination Unit GraphicSymbols

Filter/Regulator-Lubricator

Filter-Regulator-Lubricator

Combination Unit Operation

Filter/Lubricator

Page 47: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

47Littleton, CO USA Phone 303-794-2611 Fax 303-795-94871/97

Clean, regulated, lubricated compressed air.

Clean, regulated, lubricated compressed air.

Clean, lubricated compressed air.

Combination Unit Operation

Page 48: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

48 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Micro-Fog Combination Units1/8" thru 1-1/2" Port Sizes

● Same outstanding features as Norgren 07, 08, 17, 72,and 74 Series Filters, Regulators, Filter/Regulators,and Lubricators.

● Available in filter/regulator-lubricator (F/R-L), filter-regulator-lubricator (F-R-L), and filter-lubricator (F-L)combinations.

● Used in systems containing complex piping ormultiple lubrication points. Micro-Fog CombinationUnits must not be located downstream fromfrequently cycling directional control valves.

Options – Change model number as follows:ISO G Ports –

07, 08, 17 Series: Use G in the 10th position.72, 74 Series: Use G in 6th position.

ISO Rc Ports –07, 08, 17 Series: Use B in the 10th position.72, 74 Series: Use B in 6th position.

T-Handle Pressure Adjustment –07, 08 Series: Not available.17 Series: Use H in the 1st position.72, 74 Series: Use T in 7th position.

Manual drain on filter –07, 08, 17 Series: Use M in 7th position.74 Series: Use Q in 8th position.

Additional 07 Series Options:Integral wall bracket on 07 F/R-L: Use T in 2nd

position.Additional 08 Series Options –

Transparent bowls without guard: Use 00 in 5th and 6th positions and C in 9th position.

Additional 72 Series Bowl and Drain Options –Metal bowls with sight glass: Use D in 9th and

15th positions and Q (filter manual drain) or an S (filter semiautomatic drain) in the 8th position. Automatic drain can’t be used with the metal bowl.

Transparent bowls with manual drain on filter: Use T in 9th and 15th positions and Q in 8th position.

Transparent bowls with semiautomatic drainon filter:

Use T in 9th and 15th positions and S in 8th position.

Additional 74 Series Options –Transparent bowl with guard: Use P in 9th

and 15th positions.

Field AccessoriesWall Mounting Brackets –

F07: 5939-06

Ordering Information

* The 07 and 72 Series Filters and Lubricators have polycarbonate bowls without guard and with drain (diaphragm type spitter drain on the F07). **Do not use these units to control pressures outside the specified ranges. Outlet pressure adjustment ranges do not apply to filter-lubricator combinations.

MODEL NUMBERSFilter Section — Metal Bowl with Sight Glass and Automatic Drain.*

Regulator Section — Relieving Diaphragm with Gauge.Lubricator Section — Metal Bowl with Sight Glass and Manual Drain. *

Port Filter Outlet Pressure Filter/Regulator- Filter-Regulator-Size Element Rsvr. Adjustment Range Lubricator Lubricator Filter-Lubricator

Type PTF Rating Size psig (bar) ** (F/R-L) (F-R-L) (F-L) Catalog

07 Series 1/8 5µm 1-oz. 5 to 125 (0.3 to 8.6) P1H-100-A1AA P1A-100-A1AA P1C-100-A1AA NC-502, NC-5051/4 5µm 1-oz. 5 to 125 (0.3 to 8.6) P1H-200-A1AA P1A-200-A1AA P1C-200-A1AA NC-509, NC-512

72 Series 1/4 40µm 1.9-oz. 5 to 150 (0.3 to 10.4) C72H-2AK-AL3-RMG-QTN C72A-2AK-AL3-RMG-QTN C72C-2AN-AL3-NNN-QTN NC-5143/8 40µm 1.9-oz. 5 to 150 (0.3 to 10.4) C72H-3AK-AL3-RMG-QTN C72A-3AK-AL3-RMG-QTN C72C-3AN-AL3-NNN-QTN

08 Series 1/4 40µm 1/3 pt. 5 to 150 (0.3 to 10.4) C3H-260-A3DA C3A-260-A3DA C3C-260-A3DA NC-502, NC-5053/8 40µm 1/3 pt. 5 to 150 (0.3 to 10.4) C3H-360-A3DA C3A-360-A3DA C3C-360-A3DA NC-5091/2 40µm 1/3 pt. 5 to 150 (0.3 to 10.4) C3H-460-A3DA C3A-460-A3DA C3C-460-A3DA

74 Series 3/8 40µm 7-oz. 5 to 150 (0.3 to 10.4) C74H-3AK-AD3-RMG-QDN C74A-3AK-AD3-RMG-QDN C74C-3AN-AD3-NNN-QDN NCA-331/2 40µm 7-oz. 5 to 150 (0.3 to 10.4) C74H-4AK-AD3-RMG-QDN C74A-4AK-AD3-RMG-QDN C74C-4AN-AD3-NNN-QDN3/4 40µm 7-oz. 5 to 150 (0.3 to 10.4) C74H-6AK-AD3-RMG-QDN C74A-6AK-AD3-RMG-QDN C74C-6AN-AD3-NNN-QDN

17 Series 3/4 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8A-660-A3DA P8C-660-A3DA NC-502, NC-5051 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8A-860-A3DA P8C-860-A3DA

1-1/4 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8A-A60-A3DA P8C-A60-A3DA1-1/2 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8A-B60-A3DA P8C-B60-A3DA

R07, B07, L07: 18-025-003F08, L08: 3783-52R08, B08: 5203-06F17, L17 –

3/4" & 1" Ports: 6212-501-1/4" & 1-1/2" Ports: 6212-51

R17: 5570-0472 Series: 4224-5074 Series: 4324-50

Tamper Resistant Device –R07, B07: 18-001-092L07: 2117-01R08, B08: 2117-02L08: 2117-01R17, L17: Series: 2117-01R72, B72: 4255-51L72: 4050-89R74, B74: 4355-51L74: 2117-01

Page 49: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 49

Micro-Fog Combination Units

Materials of ConstructionRefer to pages 7, 17, 33, and 39.

Service Kits07 Series –

F07: 5726-04 (5µm element)R07, relieving: 3407-02L07: 3795-03B07, relieving: 3820-02

08 Series –F08: 3161-18 (40µm element)R08, relieving: 5298-14L08: 5324-02B08, relieving: 5304-06

17 Series –F17: 5311-03 (40µm element)R17, relieving: 5578-02L17: 5771-02

72 Series –F72: 5925-02 (40µm element)R72, relieving: 4381-500L72: 4382-500B72, relieving: 4383-500

74 Series –F74: 4338-05 (40µm element)R74, relieving: 4381-700L74: 4382-700B74, relieving: 4383-700

SpecificationsFluid: Compressed airMaximum Inlet Pressure –

Transparent Bowls: 150 psig (10.3 bar)Metal Bowls: 250 psig (17.2 bar)

Temperature Range –Transparent Bowls: 0° to 125 °F (-18° to

52° C)*Metal Bowls (72 Series): 0° to 150°F (-18° to

65°C)*Metal Bowls (All Others): 0° to 175°F (-18° to

79°C)*Recommended Lubricants: Use a misting

type oil rated 50 to 200 SSU (ISO Grade 7 to 46) at 100°F (38°C). The oils used must be compatible with materials of construction. Contact your lubricant supplier and the builderof the equipment to be lubricated to obtain specific lubricant recommendations.

* With dewpoint less than air temperature below 35°F (2°C).

Type A B C D E F G H J

07 Series 3.55 2.67 3.87 5.47 1.98 3.87 3.55 1.98 3.87(90) (68) (98) (139) (50) (98) (90) (50) (98)

72 Series 4.22 2.98 6.96 6.46 1.63 6.96 4.22 1.63 6.96(108) (73) (177) (164) (41) (177) (108) (41) (177)

08 Series 5.56 3.68 6.08 8.37 2.03 6.08 5.56 2.03 6.08(141) (94) (154) (213) (52) (154) (141) (52) (154)

74 Series 6.84 4.98 6.95 10.52 2.12 6.95 6.84 2.12 6.95(174) (127) (177) (276) (53) (177) (174) (53) (177)

17 Series — — — 14.75 2.22 10.44 10.25 2.22 10.44— — — (375) (56) (265) (260) (56) (265)

Dimensions in inches (mm)

Use 2" (51mm) long screws to mountPTH unit to wall. 0.174 " (4) Dia. 2 places

1.10

(28) 1.

98 (

50)

3.87

(98

)

3.72

(94

)2.

67 (

68)

1.26

(32)

1.78(45)

1.78(45)

2.13

(54

)

1.50 (38)

1.68

(43

)

A

CB

D

FE

G

JH

07 PTH Unit with Integral Bracket Filter-Lubricator (F-L)72 Series Shown, Others Similar

Filter/Regulator-Lubricator (F/R-L)72 Series Shown, Others Similar

Filter-Regulator-Lubricator (F-R-L)72 Series Shown, Others Similar

Page 50: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

50 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Oil-Fog Combination Units1/4" thru 1-1/2" Port Sizes

● Same outstanding features as Norgren 08, 17, 72,and 74 Series Filters, Regulators, Filter/Regulators,and Lubricators.

● Available in filter/regulator-lubricator (F/R-L), filter-regulator-lubricator (F-R-L), and filter-lubricator (F-L)combinations.

● Used in industrial compressed air systems tolubricate a single air tool, cylinder , valve, or other airdriven device. Oil-Fog Combination Units must notbe located downstream of frequently cyclingdirectional control valves.

Options – Change model number as follows:ISO G Ports –

08, 17 Series: Use G in the 10th position.72, 74 Series: Use G in 6th position.

ISO Rc Ports –08, 17 Series: Use B in the 10th position.72, 74 Series: Use B in 6th position.

T-Handle Pressure Adjustment –08 Series: Not available.17 Series: Use H in the 1st position.72, 74 Series: Use T in 7th position.

Manual drain on filter –08, 17 Series: Use M in 7th position.74 Series: Use Q in 8th position.

Additional 08 Series Options –Transparent bowls without guard: Use 00 in

5th and 6th positions and C in 9th position.

Additional 72 Series Bowl and Drain Options –Metal bowls with sight glass: Use D in 9th and

15th positions and Q (filter manual drain) or an S (filter semiautomatic drain) in the 8th position. Automatic drain can’t be used with the metal bowl.

Transparent bowls with manual drain on filter: Use T in 9th and 15th positions and Q in 8th position.

Transparent bowls with semiautomatic drainon filter:

Use T in 9th and 15th positions and S in 8th position.

Additional 74 Series Options –Transparent bowl with guard: Use P in 9th

and 15th positions.

Ordering InformationMODEL NUMBERS

Filter Section — Metal Bowl with Sight Glass and Automatic Drain.*Regulator Section — Relieving Diaphragm with Gauge.

Lubricator Section — Metal Bowl with Sight Glass and Manual Drain. *Port Filter Outlet Pressure Filter/Regulator- Filter-Regulator-Size Element Rsvr. Adjustment Range Lubricator Lubricator Filter-Lubricator

Type PTF Rating Size psig (bar) ** (F/R-L) (F-R-L) (F-L) Catalog

72 Series 1/4 40µm 1.9-oz. 5 to 150 (0.3 to 10.4) C72J-2AK-AL3-RMG-QTN C72B-2AK-AL3-RMG-QTN C72D-2AN-AL3-NNN-QTN NCA-333/8 40µm 1.9-oz. 5 to 150 (0.3 to 10.4) C72J-3AK-AL3-RMG-QTN C72B-3AK-AL3-RMG-QTN C72D-3AN-AL3-NNN-QTN

08 Series 1/4 40µm 1/3 pt. 5 to 150 (0.3 to 10.4) C3J-260-A3DA C3B-260-A3DA C3D-260-A3DA NC-502, NC-5053/8 40µm 1/3 pt. 5 to 150 (0.3 to 10.4) C3J-360-A3DA C3B-360-A3DA C3D-360-A3DA NC-5091/2 40µm 1/3 pt. 5 to 150 (0.3 to 10.4) C3J-460-A3DA C3B-460-A3DA C3D-460-A3DA

74 Series 3/8 40µm 7-oz. 5 to 150 (0.3 to 10.4) C74J-3AK-AD3-RMG-QDN C74B-3AK-AD3-RMG-QDN C74D-3AN-AD3-NNN-QDN NCA-331/2 40µm 7-oz. 5 to 150 (0.3 to 10.4) C74J-4AK-AD3-RMG-QDN C74B-4AK-AD3-RMG-QDN C74D-4AN-AD3-NNN-QDN3/4 40µm 7-oz. 5 to 150 (0.3 to 10.4) C74J-6AK-AD3-RMG-QDN C74B-6AK-AD3-RMG-QDN C74D-6AN-AD3-NNN-QDN

17 Series 3/4 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8B-660-A3DA P8D-660-A3DA NC-502, NC-5051 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8B-860-A3DA P8D-860-A3DA

1-1/4 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8B-A60-A3DA P8D-A60-A3DA1-1/2 40µm 1-qt. 5 to 125 (0.3 to 8.6) — P8B-B60-A3DA P8D-B60-A3DA

* The 72 Series Filters and Lubricators have polycarbonate bowls without guard and with drain. **Do not use these units to control pressures outside the specified ranges. Outlet pressure adjustment ranges do not apply to filter-lubricator combinations.

Field AccessoriesWall Mounting Brackets –

F08, L08: 3783-52R08, B08: 5203-06F17, L17 –

3/4" & 1" Ports: 6212-501-1/4" & 1-1/2" Ports: 6212-51

R17: 5570-0472 Series: 4224-5074 Series: 4324-50

Tamper Resistant Device –R08, B08: 2117-02L08: 2117-01R17, L17: Series: 2117-01R72, B72: 4255-51L72: 4050-89R74, B74: 4355-51L74: 2117-01

Page 51: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 51

Oil-Fog Combination Units

Service Kits08 Series –

F08: 3161-18 (40µm element)R08, relieving: 5298-14L08: 5324-02B08, relieving: 5304-06

17 Series –F17: 5311-03 (40µm element)R17, relieving: 5578-02L17: 5771-02

72 Series –F72: 5925-02 (40µm element)R72, relieving: 4381-500L72: 4382-500B72, relieving: 4383-500

74 Series –F74: 4338-05 (40µm element)R74, relieving: 4381-700L74: 4382-700B74, relieving: 4383-700

Materials of ConstructionRefer to pages 7, 17, 33, and 41.

SpecificationsFluid: Compressed airMaximum Inlet Pressure –

Transparent Bowls: 150 psig (10.3 bar)Metal Bowls: 250 psig (17.2 bar)

Temperature Range –Transparent Bowls: 0° to 125 °F (-18° to

52° C)*Metal Bowls (72 Series): 0° to 150°F (-18° to

65°C)*Metal Bowls (All Others): 0° to 175°F (-18° to

79°C)*Recommended Lubricants: Use a misting

type oil rated 50 to 200 SSU (ISO Grade 7 to 46) at 100°F (38°C). The oils used must be compatible with materials of construction. Contact your lubricant supplier and the builderof the equipment to be lubricated to obtain specific lubricant recommendations.

* With dewpoint less than air temperature below 35°F (2°C).

Type A B C D E F G H J

72 Series 4.22 2.98 6.96 6.46 1.63 6.96 4.22 1.63 6.96(108) (73) (177) (164) (41) (177) (108) (41) (177)

08 Series 5.56 3.68 6.08 8.37 2.03 6.08 5.56 2.03 6.08(141) (94) (154) (213) (52) (154) (141) (52) (154)

74 Series 6.84 4.98 6.95 10.52 2.12 6.95 6.84 2.12 6.95(174) (127) (177) (276) (53) (177) (174) (53) (177)

17 Series — — — 14.75 2.22 10.44 10.25 2.22 10.44— — — (375) (56) (265) (260) (56) (265)

Dimensions in inches (mm)

A

CB

D

FE

G

JH

Filter-Lubricator (F-L)72 Series Shown, Others Similar

Filter/Regulator-Lubricator (F/R-L)72 Series Shown, Others Similar

Filter-Regulator-Lubricator (F-R-L)72 Series Shown, Others Similar

Page 52: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

52 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Relief valves are used in compressed air systems to retard excessive airpressure buildup and thereby help prevent damage to system components.Relief pressure is controlled by the adjusting knob (1). Clockwise rotationincreases and counterclockwise rotation decreases the relief pressuresetting.

Inlet pressure is applied to the bottom of the diaphragm (2) and tends tomove the diaphragm upward and off the diaphragm seat (3). The reliefspring (4) applies a downward force on the diaphragm and tends to hold thediaphragm down against the seat. If the air pressure force becomes greaterthan the relief spring force, the diaphragm will move upward away from theseat. This allows air to escape through the outlet port. When the inlet airpressure decreases to the relief pressure setting, the downward force of therelief spring becomes greater than the upward force of the inlet air pressure.The diaphragm then moves down against the seat, preventing further reliefflow.

Relief Valve Graphic Symbol

Relief Valve Operation

Page 53: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 53

1

4

2

3

"T" Installation (Type V07, V74, 16-001)

Relief Flow

1

4

3 2

Relief FlowInline Installation (Type V72 Only)

Relief Valve Operation

Page 54: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

54 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

General Purpose Pressure Relief V alves1/8" thru 1" Port Sizes

● Relief pressure can be factory preset.

● Easily disassembled for servicing without removalfrom air line.

● Low torque, nonrising pressure adjustment knob onV07, V72, and V74 provides easy hand adjustment atany pressure. V74 with 250 psig spring equippedwith a T -handle adjustment. The 16-001 is equippedwith a screw adjustment.

● V72 has a bottom relief port, providing simple inlineinstallation.

● On 16-001, large diaphragm area provides closepressure control of fluid lines. Use where high reliefrates are required.

MODELS WITHOUT GAUGERelief Pressure Adjustment Ranges*

Port Size 1 to 10 psig 5 to 50 psig 5 to 60 psig 5 to 125 psig 5 to 150 psig 10 to 250 psigType PTF (0.1 to 0.7 bar) (0.3 to 3.5 bar) (0.3 to 4 bar) (0.3 to 8.6 bar) (0.3 to 10.4 bar) (0.7 to 17.2 bar) Catalog

V07 1/8 V07-100-NNAA V07-100-NNEA — V07-100-NNLA — — NC-7061/4 V07-200-NNAA V07-200-NNEA — V07-200-NNLA — —

V72 1/4 — — V72G-2AK-NFN — V72G-2AK-NMN — NC-7353/8 — — V72G-3AK-NFN — V72G-3AK-NMN —

V74G 3/8 — — V74G-4AK-NFN — V74G-3AK-NMN V74G-3AT-NSN NC-7331/2 — — V74G-4AK-NFN — V74G-4AK-NMN V74G-4AT-NSN3/4 — — V74G-6AK-NFN — V74G-6AK-NMN V74G-6AT-NSN

16-001 3/4 — 16-001-046 — 16-001-048 — — NC-7011 — 16-001-058 — 16-001-060 — —

Options. Change model number as follows:V07 –

Factory set and locked (nonadjustable) reliefpressure: Use P in the 7th position and addthe following after the model number:

Locking Method Relief Setting-T = Lock screw 003 to 125 psig-V = Lock screw with 003 to 125 psig

Loctite in screw-driver slot

-W = Pop rivet 003 to 125 psigExamples:

V07-200-PNLA-T075: Locking method: Lock screwRelief pressure setting: 75 psig

V07-200-PNAA-P005: Locking method: Pop rivetRelief pressure setting: 5 psig

Relief valve with gauge: Use G in the 8th position.

ISO G ports: Use G in 10th position.ISO Rc ports: Use B in 10th position.

V72, V74 –T-handle adjustment: Use T in 7th position.Relief valve with gauge: Use G in 10th

position.ISO G ports: Use G in 6th position.ISO Rc ports: Use B in 6th position.

16-001–Factory set and locked (nonadjustable) reliefpressure: Add the following after the modelnumber:

Locking Method Relief Setting-Y = Loctite and cut 005 to 125 psig

off adjusting screwExample:

16-001-046-Y120: Locking method: Loctite and cut off

adjusting screw.Relief pressure setting: 120 psig

Field AccessoriesV07 –

Mounting Bracket with Plastic Panel Nut: 18-025-003

Plastic Panel Nut: 2962-89Metal Panel Nut: 2962-04Tamper Resistant Seal Device for Adjusting

Knob: 18-001-094V72 –

Mounting Bracket: 4224-50Tamper Resistant Seal Device for Adjusting

Knob: 4255-51V74 –

Mounting Bracket: 4324-50Tamper Resistant Seal Device for Adjusting

Knob: 4355-5116-001 –

Mounting Bracket: 18-001-028Handwheel Conversion 1320-03

Service KitsV07: 3407-80V72: 4203-09V74: 4348-70016-001: 1112-02

Ordering Information

* Do not use these pressure relief valves to relieve pressures outside of those specified.

Page 55: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 55

General Purpose Pressure Relief V alves

SpecificationsFluid: Compressed AirTemperature –

V07, V72: 0° to 150°F (-18° to 66°C)*V74, 16-001: 0° to 175°F (-18° to 79°C)*

Gauge Ports: V07: 1/8" PTFV72: 1/8" PTFV74: 1/4" PTF16-001: 1/8" PTF

* With dewpoint less than air temperature below35°F (2°C).

Materials of ConstructionV07 –

Body: ZincBonnet: AcetalValve Seat: PolyphenyleneElastomers: Nitrile

V72 –Body: ZincBonnet: AcetalValve: BassElastomers: Neoprene

V74 –Body, Bonnet: AluminumValve: Aluminum, nitrileElastomers: NeopreneBottom Plug: Acetal

16-001 –Body & Bonnet: AluminumValve Seat & Bottom Plug: BrassElastomers: Nitrile

Dimensions in inches (mm)

H

D

J – Dia.

F –

Max

. Pan

elT

hic

knes

s GPanelHoleDia.

B

A

E

C

ReliefPort(V72)

ReliefPort(V07, V74)

JDia.

H

A

B

C

D

K

L

M

P

NRO

T

S

K

L

M

S R

O

T P

U

V

N

Port CL

Port CL

V74 Shown,V07 and V72 Similar V72 and V74 Bracket

K

PR

NO

S

M L

18-001-028 (16-001)16-001 V07 Bracket

C

Type A B Knob* T-handle D E F G H J

V07 1.63 0.36 2.91 — 0.75 0.95 0.25 1.19 2.13 1.50(41) (9) (75) — (19) (24) (6) (30) (54) (38)

V72 1.98 0.98 3.86 5.01 0.96 1.01 0.16 1.57 2.34 1.50(45) (25) (98) (127) (24) (26) (4) (40) (59) (38)

V74 3.15 1.69 6.67 7.64 1.45 1.24 0.25 2.06 3.65 2.00(80) (43) (170) (194) (37) (31) (6) (52) (93) (51)

16-001 5.00 1.50 9.50 — 2.50 — — — 3.75 2.00(127) (41) (241) — (64) — — — (95) (51)

K L M N O P R S T U V

1.50 2.47 1.41 1.00 0.38 0.69 0.31 0.51 0.22 — —(38) (63) (36) (25) (10) (18) (8) (13) (6) — —

1.65 2.36 1.50 2.00 1.54 0.24 0.47 0.79 0.20 0.16 0.71(42) (60) (38) (51) (39) (6) (12) (20) (5) (4) (18)

2.72 3.11 2.00 2.40 1.97 0.24 1.00 1.46 0.16 0.20 0.77(69) (79) (51) (61) (50) (6) (25) (37) (4) (5) (20)

4.88 3.19 2.94 2.00 0.50 3.25 0.63 0.33 — — —(124) (81) (75) (51) (13) (83) (16) (8) — — —

* Screw adjustment on 16-001.

Page 56: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

56 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Miniature Pressure Relief V alves1/8" and 1/4" Port Sizes

● Miniature tank relief valve for use in low volume airtanks.

● Compact, economical low capacity relief valve.

● Brass and stainless steel construction for com -pressed air and water service.

● Available with factory preset relief pressure setting.

MODEL NUMBERS

Pipe Relief Pressure Adjustment Ranges*Size 25 to 50 psig 25 to 75 psig 50 to 150 psig 50 to 300 psig

Type NPTF (1.7 to 3.5 bar) (1.7 to 5.2 bar) (3.5 to 10.4 bar) (3.5 to 20.7 bar) Catalog

Adjustable 1/8 16-004-001 16-004-002 16-004-003 16-004-004 NC-7031/4 16-004-009 16-004-010 16-004-011 16-004-012

Ordering Information

* Do not use these pressure relief valves to relieve pressures outside of those specified.

Options.For factory set and locked (nonadjustable) reliefpressure, add the following after the model num-ber:

Locking Method Relief Setting-Z = Loctite adjusting cap 025 to 300 psigExample:

16-004-001-Z025Locking method: Loctite capRelief pressure setting: 25 psig

Page 57: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 57

Miniature Pressure Relief V alves

SpecificationsFluid: Compressed air or waterTemperature Range: 0° to 200°F (-18° to 93°C)

with dewpoint less than air temperaturebelow 35°F (2°C).

Repeatability: ± 20 % of relief setting.

Materials of ConstructionBody, Cap, Springrest: BrassValve: Brass and NitrileRegulating Spring: Stainless Steel

0.79(20) Dia.

1.56*(62)

* 1.56 (62) for 1/8" pipe size; 1.75 (44) for1/4" pipe size.

Dimensions in inches (mm)

Page 58: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

58 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Water Relief V alves1/8" and 1/4" Port Sizes

● In-line mounting standard. Optional panel or wallmounting accessories available.

● Can be factory preset.

● Easily disassembled for servicing without removalfrom air line.

● Brass body with brass or plastic bonnet.

Options. Change model number as follows:Factory set and locked (nonadjustable) reliefpressure: Use P in the 7th position and addthe following after the model number:

Plastic BonnetLocking Method Relief Setting-R = Wire seal 003 to 100 psigExample:

V06-121-PNKA-R075: Locking method: Wire sealRelief pressure setting: 75 psig

Brass BonnetLocking Method Relief Setting-K = Lock nut 003 to 100 psigExample:

V06-122-PNAA-K005: Locking method: Relief pressure setting: 5 psig

Relief valve with gauge: Use G in 8th position.

AccessoriesMounting Bracket with Panel Nut –

Use with plastic bonnet: 18-025-003Use with brass bonnet: 18-001-020

Panel Mounting Nut –Use with plastic bonnet: 2962-89Use with brass bonnet: 616-01

Tamper Resistant Seal Wire for use withAdjusting Knob: 2117-01

Service KitsElastomers: 3439-11

Ordering Information

* Do not use these pressure relief valves to relieve pressures outside of those specified.

MODELS WITHOUT GAUGE

Port Relief Pressure Adjustment Range *Bonnet Size 1 to 10 psig 3 to 50 psig 5 to 100 psigType PTF (0.1 to 0.7 bar) (0.2 to 3.5 bar) (0.3 to 6.9 bar) Catalog

Plastic 1/8 V06-121-NNAA V06-121-NNEA V06-121-NNKA NC-7021/4 V06-221-NNAA V06-221-NNEA V06-221-NNKA

Brass 1/8 V06-122-NNAA V06-122-NNEA V06-122-NNKA NC-7021/4 V06-222-NNAA V06-222-NNEA V06-222-NNKA

Page 59: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 59

Water Relief V alves

SpecificationsFluid: Water or Compressed AirTemperature:

Plastic Bonnet: 35° to 150°F (2° to 66°C)Brass Bonnet: 35° to 175°F (2° to 79° C)

Gauge Ports: 1/8 PTF

Materials of ConstructionBody: BrassBonnet: Acetal or BrassValve Seat: PPO PlasticDiaphragm: Nitrile

A

C

D

E – Max.Panel

Thickness

BG

H Dia.

F – PanelHole Dia.

K

L

M

P

NRO

T

S

V06 With Plastic Bonnet

AC

DE – Max.

PanelThickness

BGF – Panel

Hole Dia.

H Dia.

V06 With Brass Bonnet 18-025-003 (V06 Plastic Bonnet)

K

L

M

P

NRO

S

18-001-020 (V06 Brass Bonnet)

BonnetType A B C D E F G H K L M N O P R S T

Plastic 1.50 0.38 2.69 1.00 0.25 1.19 2.13 1.50 1.50 2.47 1.41 1.00 0.38 0.69 0.31 0.51 0.22(38) (10) (68) (25) (6) (30) (54) (38) (38) (63) (36) (25) (10) (18) (8) (13) (6)

Brass 1.50 0.38 3.38 1.03 0.25 0.81 2.13 1.50 1.38 2.41 1.41 1.00 0.38 0.69 0.31 0.22 —(38) (10) (86) (26) (6) (21) (54) (38) (35) (61) (36) (25) (10) (18) (8) (6) —

Dimensions in inches (mm)

Page 60: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

60 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

AccessoriesHanging Hook: 5320-0110" Extension Nozzle: 5363-5018" Extension Nozzle: 5363-51

Materials of ConstructionBody: Polyester PlasticNozzle Tip: Metal (Aluminum or Brass) or

RubberElastomers: Nitrile

SpecificationsFluid: Compressed AirMaximum Temperature: 250 psig (17.2 bar)Temperature Range: 32° to 175°F (0° to

79°C)Outlet (Regulated) Pressure: Below 30 psig

(2.1 bar)Nozzle Orifice: 0.16" (4mm) diameter

PortSize

NPTF Nozzle Type MODEL NUMBER Catalog

1/4 Metal Tip with Air Shield 17-104-302 NC-8081/4 Metal Tip without Air Shield 17-104-304 NC-8081/4 Rubber Tip without Air Shield 17-104-306 NC-808

Ordering Information

Regulated Blow Gun1/4" Port Size

● Lever type blow gun controls direction and flow ofcompressed air .

● Built-in pressure regulator limits nozzle pressure to 30 psig (2.1 bar), even when nozzle is obstructed.

● Permanently assembled, tamper resistant construction.

● Large lever for comfort and easy actuation.

● Replaceable nozzle tip with or without air shield.

● Models available with metal or rubber tip. Ordermodels with rubber tip to reduce surface scratching.

Page 61: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

Ordering Information

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 61

Drip Leg Automatic Drain1/2" Port Size

● Can be disassembled and serviced without removalfrom the air line.

● Automatic drain is ported 1/8" NPT for ease in pipingaway expelled liquids.

● Drain opens when system is not pressurized,allowing water to escape by gravity.

● Water level actuates automatic drain float duringnormal operation.

PortSizeNPT Bowl Size Bowl Type MODEL NUMBER Catalog

1/2 1/3 Pint Metal Bowl with Sight Glass 17-016-107 NC-8051/2 1/3 pint Transparent Bowl 17-016-104 NC-8051/2 3 Ounce Transparent Bowl 17-016-102 NC-805

SpecificationsFluid: Compressed airMaximum Inlet Pressure:

Transparent Bowl: 150 psig (10.3 bar)Metal Bowl: 250 psig (17.2 bar)

Maximum Temperature:Transparent Bowl: 125°F (52°C)Metal Bowl: 175°F (79°C)

Automatic Drain Connection: 1/8" NPTF

Materials of ConstructionBody: ZincTransparent Bowl: PolycarbonateMetal Bowl: ZincDrain Mechanism: Acetal, Nitrile, Stainless

Steel

Dimensions in inches (mm).

1.34 (34)Radius

2.31 (59)Dia.

1/2-14 PTF

6.22

(15

8)

. 4.75

(12

1)

1/3 Pint Bowl 3 Ounce Bowl

Page 62: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

A

CB

AC

B

A

CB

62 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

High Pressure Needle V alves1/8" and 1/4" Port Sizes

● Rugged brass body .

● Brass needle with T eflon ® seal.

● Tapered needle provides accurate metering of fluids.

MODEL NUMBERS - Dimensions in inches (mm)

Dimensions in inches (mm)Ports C

In Out PTF A B Closed Open Catalog

Male Male 1/8 1.63 0.38 2.13 2.25 17-001-106 — — NC-801(41) (10) (54) (57)

1/4 1.81 0.38 2.13 2.25 17-001-107 — —(46) (10) (54) (57)

Female Female 1/8 1.63 0.38 2.13 2.25 — 17-001-109 — NC-801(41) (10) (54) (57)

1/4 1.63 0.38 2.13 2.25 — 17-001-110 —(41) (10) (54) (57)

Female Male 1/8 1.63 0.38 2.13 2.25 — — 17-001-112 NC-801(41) (10) (54) (57)

Male Female 1/4 172 0.38 2.13 2.25 — — 17-001-114 NC-801(44) (10) (54) (57)

Ordering Information

SpecificationsFluid: Compressed air, water, steam, and

other non-flammable, inert gases andliquids.

Maximum Inlet Pressure: 3000 psig (207 bar)Temperature Range: -40° to 500°F (-40° to

260°C)Port Size: 1/8" or 1/4" NPTOrifice Size: 0.187" (5mm)Cv: 0.401

Materials of ConstructionBody, needle: BrassElastomers: Teflon®

Page 63: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 63

Differential Pressure Indicator1/8" Port Size

● Indicates at a glance when pressure differential iswithin specified limits.

● Light weight construction.

● In-line or bottom ports.

● Full 360 ° visibility of the red/green pressureindicator .

Ordering Information

SpecificationsFluid: Compressed airMaximum Inlet Pressure: 250 psig (17.2 bar)Temperature Range: 0° to 175°F (- 18° to

79°C)Maximum Differential Pressure: 15 psid (1 bar)Indicator Color Code –

0 to 5 psid Models –Green: Pressure drop less than 0.5 psid

(0.04 bar)Green/Red: Pressure drop between 0.5 and

4.5 psid (0.04 and 0.31 bar)Red: Pressure drop greater than 4.5 psid

(0.31 bar)0 to 15 psid Models –

Green: Pressure drop less than 4.5 psid (0.31 bar)

Green/Red: Pressure drop between 4.5 and 15 psid (0.31 and 1.03 bar)

Red: Pressure drop greater than 15 psid (1.03 bar)

Materials of ConstructionIndicator Body: Transparent nylonAdapter Body: AluminumInternal Parts: AcetalSpring: Stainless steelElastomers: Nitrile

Dimensions in inches (mm).

MODEL NUMBERSPort Size 0 to 5 psid 0 to 15 psid

Mounting NPT (0 to 0.35 bar) (0 to 1.3 bar) Catalog

In-line Ports 1/8" 18-033-104 18-033-101 NC-822Bottom Ports 1/8" 18-033-105 18-033-102 NC-822

0.35

(9)

Inlin

e P

ort

s1.61 (41) Dia.

0.88 (22)Bottom Ports

1.36

(35

)

2.06

(52

)

Page 64: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

64 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Sizing Filters, Regulators, and Lubricators(FRL’s)

Maximum Recommended Air Flow (scfm) thru ANSI Standard Weight Schedule 40 Pipe

Applied Nominal Standard Pipe SizePressure

psig 1/8" 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3"

5 0.5 1.2 2.7 4.9 6.6 13 27 40 80 135 240

10 0.8 1.7 3.9 7.7 11.0 21 44 64 125 200 370

20 1.3 3.0 6.6 13.0 18.5 35 75 110 215 350 600

40 2.5 5.5 12.0 23.0 34.0 62 135 200 385 640 1100

60 3.5 8.0 18.0 34.0 50.0 93 195 290 560 900 1600

80 4.7 10.5 23.0 44.0 65.0 120 255 380 720 1200 2100

100 5.8 13.0 29.0 54.0 80.0 150 315 470 900 1450 2600

150 8.6 20.0 41.0 80.0 115.0 220 460 680 1350 2200 3900

200 11.5 26.0 58.0 108.0 155.0 290 620 910 1750 2800 5000

250 14.5 33.0 73.0 135.0 200.0 370 770 1150 2200 3500 6100

The flow values in the preceding table are based on a pressure drop of 10% of the applied pressure per 100 feet of pipe for 1/8", 1/4",3/8", and 1/2" pipe sizes; and a pressure drop of 5% of the applied pressure per 100 feet of pipe for 3/4", 1", 1-1/4", 2", 2-1/2", and 3"pipe sizes.

When selecting the individual FRL Unit, the airconsumption of the tools to be serviced should becorrelated with the flow capacity of the FRL Unit.Norgren FRL Units have been designed to flow air in

excess of that indicated in the following table. The tablegives recommended flows for pipe sizes at listedpressures and should be used to determine appropriatepiping for air systems.

Page 65: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

1/97 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 65

Absence of an Industrial Standard for RatingPneumatic Filter Elements There is not an industry wide standard for establishingthe micron rating of pneumatic filter elements.Standards by various industry associations, includingthe National Fluid Power Association (NFPA) andInternational Standard Organization (ISO), are indiscussion. In the absence of an industry standard,some manufacturers of pneumatic filters make claimsconcerning the micron rating of their so called“standard” element which can not be substantiated andare probably not valid.

Norgren’ s Method of Rating and T esting Pneumatic Filter Elements Norgren particle removal filter elements are rated by thesize of the particle they will trap (i.e., a 40-micronelement will remove particles 40-microns and larger).Norgren tests filter elements by using standard coarseand fine test dusts of known particle size distribution.Coarse dust consists of 12% particles smaller than 5-microns; fine grain dust consists of 39% particlessmaller than 5-microns. Test results show that aNorgren filter element rated at 40-microns actuallyremoves over 98% of particles 5-microns and larger.

How to Size a Filter ElementThe downstream equipment being protected determinesthe micron rating of the filter element. Industrial tools,such as air hammers and drills, typically require only a40-micron element. Air operated instruments and small,high speed tools typically require a 5-micron element.Always consult the equipment manufacturer for filtrationrequirements.

Generally, the smaller the micron rating of the element,● the higher the pressure drop across the filter,● the shorter the element service life.

Therefore, the use of a 5-micron element where a 40-micron is adequate penalizes the customer in increasedpressure losses and frequent down time for changing orcleaning the filter element.

ISO Standard 8573-1. Compressed Air for General Use Contaminant’s found in industrial compressed airsystems include solid particles, water, and oil. ISO 8573-1:1991 provides a simple method of classifying thesecontaminant’s. A quality class required for a particularapplication can be defined by listing, in order, the classrequired for solids, water, and oil.

Examples:

Air of Quality Class 2.2.2 is filtered to 1µm solid particlesize, dried to -40°C pressure dewpoint, and filtered to anoil concentration of 0.1mg/m3.

Air of Quality Class 5.3.4 is filtered to 40µm solid particlesize, dried to -20°C pressure dewpoint, and filtered to anoil concentration of 5mg/m3.

When a class for a particular contaminant solid, water, oroil is not specified, the number designating the class isreplaced with a hyphen.

Example: Air of Quality Class 1.–.1 does not specify thepressure dewpoint.

Table 1. Summary of ISO 8573-1:1991 Air Quality Classes *

Solid Water OilParticle Maximum Maximum

Maximum Pressure RemainingQuality Size Dewpoint Oil ContentClass µm °C mg/m3 **

1 0.1 -70 0.012 1 -40 0.13 5 -20 14 15 +3 55 40 +7 256 — +10 —

* See ISO standard 8573-1 for complete information.** At 1 bar absolute pressure.

Rating Filter Elements and ISO Standard 8573-1

Page 66: Table of Contents - Dominion Industrial2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97 Compressed Air Systems and Air Air Preparation Products Dryers When air is compressed,

66 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1/97

Warning/W arranty

WarningThese products are intended for use in industrial

compressed air systems only. Do not use these products wherepressures and temperatures can exceed those listed underSpecifications.

Before using these products with fluids other than thosespecified, for non-industrial applications, life-support systems,or other applications not within published specifications, consultNorgren.

Through misuse, age, or malfunction, components used influid power systems can fail in various modes. The systemdesigner is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provideadequate safeguards to prevent personal injury or damage toequipment in the event of such failure. System designersmust provide a warning to end users in the systeminstructional manual if protection against a failure modecannot be adequately provided.

System designers and end users are cautioned to reviewspecific warnings found in instruction sheets packed andshipped with these products. System designers should alsoprovide for all OSHA requirements including Title 29 CFR1910.147 Lockout/Tagout.

It should be recognized that warnings are valid for anyproduct, regardless of manufacturer, and are not restricted toproducts manufactured by Norgren. Norgren’s reputation forproduct quality and performance is well established. We feelwe have the additional obligation to provide information orwarnings to customers to assist them in applying our productsin a reasonable and safe manner.

Limited W arranty , Disclaimer & Limitation ofRemedies

Items sold by Norgren are warranted to be free fromdefects in materials and workmanship for a period of twoyears from the date of manufacture, provided said items areused according to Norgren's recommended usages.Norgren's liability is limited to the repair of, refund of purchaseprice paid for, or replacement in kind of, at Norgren's soleoption, any items proved defective, provided the allegedlydefective items are returned to Norgren prepaid. Thewarranties expressed above are in lieu of and exclusive of allother warranties.

There are no other warranties, expressed or implied,except as stated herein. There are no implied warrantiesof merchantability or fitness for a particular purpose,which are specifically disclaimed. Norgren's liability forbreach of warranty as herein stated is the exclusiveremedy, and in no event shall Norgren be liable orresponsible for incidental or consequential damages,even if the possibility of such incidental or consequentialdamages has been made known to Norgren.

Norgren reserves the right to discontinue manufacture ofany product or change product materials, design, orspecifications without notice.