  • Power Protection for Business-Critical Continuity

    Tailored Solutions for Power Protection

  • Trouble is Coming Down The LineAnd You Must BePrepared

    Every operation in your business depends upon the instant, around-the clock availability of computers, servers and other electronic systems. If they aren’t working, neither is your company.

    Unfortunately, every piece of this equipment your company possesses is subject to the whims of the electricity that powers it.

    The first step in taking control of this situation is to understand the threats to your system reliability — and exactly what you can do about them.

    The Ability ToTailor a PowerSolution Is WhatSets EmersonNetwork Power Apart

    We Know The Importance Of Achieving Protection For Today…And Planning For TomorrowThe decisions you make now are going to impact your ability to efficiently grow into the future. As a power partner that truly understands the importance of genuine reliability, we can implement the best way to achieve it for your operations. Based on our years of experience, we know and understand your current needs for protection — and what it will take to increase your power capabilities as these demands grow. We can help you protect data, hardware and system availability in any combination.

    No Matter How Deep Your Protection Needs To Be, We Have The Expertise To Make It HappenWe recognize that not everyone requires the same level of power protection. Liebert has the knowledge of critical facilities and equipment that is necessary to determine the exact needs of each application. An extensive range of power protection choices then enables us to match our equipment precisely to these parameters rather than force-fitting a few products to every situation. The result is our unique ability to deliver power solutions that are always on target for the depth of protection specified.

  • No Organization In The Power Protection Business Has More Real-World Experience Than Emerson Network Power

    Many years of experience allow us to properly respond to any power problem scenario. Our resources include knowledgeable leadership, as well as an outstanding staff of research, design, application and service engineers using the latest technological tools.

    But the biggest difference in the way we approach your power requirements is the local Liebert Representative, Distributor or Reseller. We are the only company in this business that maintains such a strong local presence on a national and international basis. Specifying and maintaining a high availability power system requires someone who is knowledgeable in all phases of critical systems protection. This resource, coupled with our broad product line, gives Liebert the ability to create a “tailored solution” that will meet your protection needs precisely and efficiently. We don’t have to take the one or two items we happen to have and stretch them to come up with the answer. We give you the best answer every time.

    Only Liebert can bring together all of the power protection solutions you need to create system availability that is as close to 100% reliability as possible.

    There Is A Liebert Power Solution To Meet Every NeedNo one offers a more comprehensive selection of power products for critical applications than Liebert.

    Liebert PS (400 VA/600 VA) 4-5A Reliable Power Protection For Your PC

    Liebert Series 7400 M (10/30/40/60 kVA) 20-21Maximum Protection ForMission Critical Network Applications

    Liebert iTrust 3-Phase UPS System 22-23True On-Line Sinewave UPS System ForThe Networked Economy

    Liebert NX Series 24-25

    The Next Generation UPS System

    Liebert Hipulse UPS (30-150 kVA 1-Phase) 26-27

    Digital UPS For The Digital World & Industrial Automation

    Liebert Hipulse UPS (80-800 kVA 3-Phase) 28-29

    Digital UPS For The High-End Digital World

    ASCO Switch 34-35

    Designed To Minimize Downtime OnCritical Systems

    Liebert Powersure Panel 32-33

    Transient Voltage Surge Supressor

    Liebert ITON 600 VA /1000 VA 6-7

    A Reliable Power Protection And Backup Solution For Your PC

    TMLiebert UPStation GXT 2U 1 /2 /3 8-9

    True Online Double Conversion UPS to Keep Your Business Up and Running

    True On-line DSP Based UPS With Unity Power Factor

    Liebert Super 400D (10/20 kVA) 18-19

    Liebert Precision Power Center 30-31

    Affordable Packaged Power ManagementFor Higher Power Quality

    TMLiebert UPStation GXT 2 (4.5 kVA / 6 kVA) Series 10-11

    The New Shape Of Network Power Protection

    TMLiebert UPStation GXT-MT 1-2-3 kVA UPS 12-13

    True Online Double Conversion UPS with Extended Runtime Capability

    TMLiebert UPStation GXT-MT 6 /10 kVA UPS 14-15

    Fit-And-Forget UPS System Power Protection And Power Source

    TMLiebert UPStation GXT RT 1-3 kVA UPS 16-17

    True Online Double Conversion UPS with Extended Runtime Capabilities with Rack & Tower Compatibility

  • 2

    You Face ManyChallenges in the Pursuit of Uptime

    Is There Really A Problem?“My computer can ride right through a short blip in the power — why do I need anything else?”

    There Are No Simple Solutions“I have people telling me all I need to do is plug each workstation into a small UPS from the computer store . That’s good enough, isn’t it?”

    Different Needs Require Different Power Protection

    Configurations“Should I have a small UPS for each workstation or have everything on one large system . Which is best for my facility?”

    A Lot Can Happen Between Your UPS And The Equipment

    It Is Protecting“We have dozens of pieces of networking equipment. How can I make sure that each one is getting exactly the power it needs?”

    Every Wire Carries The Potential For Trouble“An electrical surge came in through an outside phone line and knocked out our entire communications system. Is this going to happen again?”

    A Single Source Of Power Simply May Not Be Enough“Adding a second power feed would certainly enhance our availability picture — but who can we talk to about getting it done right?”

  • 3

    But There AreReal Solutions

    You Need Protection From All Power ProblemsAn outage is just the problem you can see. There are many other more frequent power fluctuations — surges, spikes, sags — that you don’t see. Theseare the conditions that cause the “unexplained” lock-ups.

    “Out-Of-The-Box” Can Put You Out Of BusinessBuying a simple off-line UPS down at the computer store may be a good solution for your home PC, but it just doesn’t make sense when your business and productivity are on the line. Protecting critical network and computing systems requires the expertise of someone who understands all the risks you face from poor power quality problems with critical equipment.

    Centralized Vs. Distributed UPS ProtectionLiebert has the breadth of products that allows you to implement either a centralized or a one-on-one distributed power protection strategy depending on your requirements. Whatever configuration you choose, you can count on Liebert to make it the best it can be. Benefits, suchas increased system security, more efficient maintenanceand improved reliability, make a centralized strategy a better choice for larger operations.

    Proper Power Depends On Proper DistributionIn network applications, there may be hundreds of different loads with various voltage requirements, a mix of AC and DC power, plus any number of other electrical Specifications This calls for adistribution system that is designed to maintain the highest levels of reliability and quality between the source of conditioned power and the protected equipment.

    Power Conditioning And Surge Protection Throughout The FacilityRaw utility power is often far too “dirty” for sensitive systems, resulting in lost,or garbled data, unexpected software glitches or shutdowns, even hardware damage. The IEEE recommended practice is to install transient voltage surge suppression (TVSS) protection on every electrical conductor that penetrates a facility shell, including power lines, telephone and other communications links.

    Maximum Reliability Demands Dual Power SourcesIf your needs require the highest level of system availability, Liebert has the knowledge and products to implement a dual-power strategy throughout your enterprise. UPS, transfer switching, power distribution and other equipment are all brought together to create the ultimate in reliability.

  • 4

    Liebert PSA Reliable Power Protection For Your PC

    Applications• TFT Monitors

    • Personal Computers

    • Printers

    • Modems

    • Routers

    • Wireless Devices

    • Non-critical passive devices

    • Standalone Computers

    Features• High Frequency Charger Design

    • Input Fuse Protected

    • Black Start Mode Available

    • Separate Low Charge &

    • Battery Indicator in AC mode

    • Overload, Discharge

    • and Overcharge Protection

    • Output Cable Provided

    Liebert PS (400 VA/600 VA)

    A high-performance UPS designed especially to protect low voltage applications and is available in tower design

    The Liebert PS' features and flexibility makes it the optimal solution for your small electronic devices both at home and office.

  • 5

    Technical Data

    Liebert PSA 400 Liebert PSA 600

    VA/W

    Voltage

    Voltage Range

    Voltage

    Voltage Regulation(Batt.

    Mode)

    Frequency

    Frequency Regulation

    (Batt. Mode)

    Output Waveform

    Battery Type & Number

    Back up Time (at a PC

    load with 15" monitor) 5 minutes 8 minutes

    Recharge Time

    Typical

    Green LED flashing every second

    Red LED flashing every 2 seconds for 30

    seconds

    AC Mode

    Battery Mode

    Low Battery at Battery

    Mode

    Fault

    Battery Weak at AC Mode

    Battery Fault at AC

    Mode Red LED flashing three times every 2 seconds

    Sounding every second

    Sounding every 2 seconds for 30 seconds

    Battery Mode

    Low Battery at Battery

    Mode

    Fault

    Battery Weak at AC Mode

    Battery Fault at AC

    Mode Sounding three times every 2 seconds

    Full Protection

    Dimension, DXWXH (mm)

    176.5x80x230

    Net Weight (kgs)

    Operating Environment

    Noise Level

    MODEL

    CAPACITY

    INPUT

    OUTPUT

    BATTERY

    TRANSFER TIME

    INDICATOR

    AUDIBLE ALARM

    PROTECTION

    PHYSICAL

    ENVIRONMENT

    Continuously s ounding

    400VA/200W 600VA/300W

    220/230/240VAC

    170-270VAC

    220/230/240VAC

    50Hz

    Modified Sinewave

    2-6ms

    +/-1 Hz

    ±10%

    12V/7AH x 1pc 12V/4.5Ah x 1pc

    10 hours to 90% after complete discharge

    Green LED lighting

    Green LED flashing every 4 seconds

    Red LED lighting

    Sounding every 4 seconds

    3.1 3.3

    0- 40°C, 0-90 % relative humidity (noncondensing)

    Less than 40dB

    Discharge, overcharge, and overload protection

  • 6

    Liebert ITONA Reliable Power Protection And Backup Solution For Your PC

    Applications

    Liebert ITON 600/1000

    Features

    A • uto

    n est• sta R art

    p eSlee Mod

    I

    r pr t o f r F / ePowe otec i n o ax Mod m

    art n i g SSm Mo itor n oftware

    art i r o s o o lSm M c opr ce s r c ntro

    m rt echn loS a AVR T o gy

    o i a o PoC mmun c ti n rt

    v lo o ec n O er ad Pr t tio and alarm

    • Home PC

    • Printers

    • Clustered network equipment: hubs, routers, bridges

    • Remote telecommunications units

    • Desktop Speakers

    • Office Telecommunications systems

    • Voicemail and e-mail servers

    • Test and diagnostic equipment

    A best-in-class UPS with proven reliability. ITON is an uptime solution for your personal computers & peripherals and is available in a compact tower design

    A line interactive UPS that provides perfect power protection for Small Office & Home Office (SOHO) PC Systems

    • Chargers

    • Telecom Ports

  • 7

    Technical Data

    MODEL ITON 600 ITON 1000 CAPACITY VA/W 600 VA/360W 1000VA/600W

    Voltage Range 140-300 VAC 160-270V

    INPUT

    Frequency 45-65 Hz (Auto sensing)

    Voltage 230V

    (Batt. Mode) Voltage Regulation

    +/- 10% +/- 5%

    Frequency 50Hz 50Hz or 60Hz

    (Batt. Mode) Frequency Regulation

    +/- 1Hz

    Output Waveform Stepped Waveform

    OUTPUT

    Overload 110% for 5 minutes as “Mains” mode

    Battery Type & Number 12V/7AH — 1 PC 12V/7AH — 2 Pcs Backup Time* (As per the loads)

    15-22* mins 30 min typical* (with 1 PC)

    BATTERY

    Recharge Time 8 hours to 90% after complete discharge

    TRANSFER TIME

    Typical 4-8 ms 4-6 ms

    INDICATOR (LED Bar Graph)

    AC Mode Green Lighting

    The 1st green lighting; The Green 2nd to 5th green gradually

    Lighting lighting indicating load capacity

    Backup Mode Green flashing Green

    flashing

    The 1st green flashing; The 2nd to 5th green gradually lighting indicating batteries capacity

    Fault The red lighting

    Backup Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0.5 seconds Battery Replacement Soundingevery 2 seconds

    AUDIBLE ALARM

    Fault Continuously Sounding

    PROTECTION Full Protection Discharge, overcharge, and overload protection

    PHYSICAL

    ENVIRONMENT

    Dimension (mm), DxWxH 330x100x140 369x141x181 Net Weight 6 kg 13.5 kg

    Operating Environment 0-40 C, 0-90% relative humidity

    (non-condensing) Noise Level Less than 40 dB

    INTERFACE

    RS-232 Support Windows 98/NT/ME/2000/2003/ XP, Linux, HP-UX, IBM AIX,

    Sun Solaris, Unixware, Free BSD, Mac OS and Compaq True

  • 8

    Liebert GXT 2UTrue Online Double Conversion UPSTo Keep Your Business Up And Running

    Features• True on-line design

    • Configurable as rack or tower

    • Wide input voltage window allows• UPS support without going to battery,• extending systems availability

    • Built-in Surge Suppression

    • User replaceable batteries without• removing GXT 2U from rack

    • Compatible with new SNMP / Web Card

    • Compatible with Multiport 4 or 8

    • Compatible with RelayCard INT

    • Compatible with MultiLink

    A high-performance UPS with proven reliability, custom configurability, hot-swap internal batteries and extendible runtime in a compact tower design.

    The GXT2 features and flexibility make it the optimalsolution for small server room,networking and telecomapplications that requirereliable, continuous andquality power.

    • LAN and WAN servers

    • Clustered network equipment: hubs, routers, bridges

    • Remote telecommunications units

    • Office Telecommunications systems

    • Voicemail and e-mail servers

    • Test and diagnostic equipment

    • Engineering network servers

    • Factory floor protection of micro processor controlled equipment

    • Mission critical devices

    Applications

    TMUPStation GXT 2U in Rack and Tower Mode

  • 9

    Technical Data

    Description 1 kVA 2 kVA 3 kVAUPStation GXT 2U UPStation GXT 2U UPStation GXT 2U1000 2000 3000

    Input Parameters

    Nominal Voltage 230 VAC

    Voltage Range 119 - 280VAC ( Load Dependent )

    Frequency Range 40 Hz - 70 Hz

    Power Factor > 0.97

    Output Parameters

    Capacity 1 kVA / 0.7 kW 2kVA / 1.4 kW 3kVA / 2.1 kW

    Voltage User Configurable 200 / 208 / 220 / 230 / 240 VAC

    Voltage Regulation + / - 3% Steady state

    + / - 5% if synchronized to mains,

    Frequency Regulation + / - 0.1 Hz free running or on battery operation ( when not synchronized to mains )

    THD

  • 10

    A high-performance UPS with proven reliability, custom configurability,hot-swap internal batteries and extendible runtime in a compact rack and tower design.

    The GXT2 features and flexibility make it the optimalsolution for your small & medium server, data room, networking and telecom applications that require reliable, continuous and

    Liebert GXT 2 (4.5 kVA / 6 kVA)The New Shape Of Network And Power Protection

    Applications• LAN and WAN servers• Clustered network equipment: hubs, routers, bridges• Remote telecommunications units• Office Telecommunications systems• Voicemail and e-mail servers• Test and diagnostic equipment• Engineering network servers• Factory floor protection of micro processor controlled equipment• Mission critical devices

    Features• True on-line design• Built-in PFC circuit• Wide input voltage window allows• UPS support without going to battery,• extending systems availability• Builtin Surge Suppression• Compatible with new SNMP / Web Card• Compatible with Multiport 4 or 8• Compatible with RelayCard INT• Compatible with MultiLink• External plug and play Battery cabinets available• Configurable as rack or tower Other product features of the Liebert GXT2 include• Self-diagnostics• Built-in serial communications for use with Liebert • TMMultiLink Automated Shutdown Software• TMIntellislot communications port• Built-in closure signals• Includes Windows-based configuration program

    TMUPStation GXT 2 (4.5 kVA / 6 kVA)in Rack and Tower Mode

    quality power.

  • 11

    Technical Data

    Output Ratings

    Output Power 4.5 KVA/3.15Kw, 6 KVA/4.2KwNominal Output Voltage 230 VACOutput Voltage Regulation +/-2%Output Voltage Distortion-With 100% Linear Load < 3%Nominal Output Frequency 50 HzOutput Frequency Tolerance 46.5 Hz to 53.5Hz( Phase locked with Mains ) +/-3.5 Hz Synchronized to mainsOverload at 0.7 pf( Load is transferred to Bypass 125% for 10 SecAfter pre-determined timeLoad Power Factor Range 0.7 lagging to unity

    Input Ratings

    Nominal Input Voltage 220/230/240 VACPermissible Input VoltageVariation at Full Load 176-276 VACNominal Input Frequency 50 HzPermissible Input FrequencyVariation 40 to 70 HzPower Factor at Full load > 0.97

    Battery Details (External)

    Nominal DC Bus Voltage 240 VDCNumber of Blocks of SMFBatteries 20 blocks of 12 V eachTypes of Batteries Supported Sealed Maintenance Free (SMF)Recharge Time up to 100% Capacity 10 hours to 12 hours

    Physical Parameters

    Width X Depth X Height (mm) 221x547x430Weight 67 kg

    Environmental Parameters

    oOperating Temperature at Rated Load 0 to 40 CoStorage Temperature - 15 to + 50 C

    Relative Humidity 0 to 95% RHNoise < 55 dB

    Agency

    Safety EN62040-1-1, TUV/GSRFI / EMI AS 62040-2, EN 50091-2, Class A CE EMC DirectiveSurge Immunity EN 61000 4-5 Level 3 criteria ATransportation ISTA Procedure 1B

  • 12

    Liebert GXT-MT 1-3kVA UPSTrue Online Double Conversion UPS With Extended Runtime Capabilities

    Applications• Small Size Data Center

    • Telecommunication, VoIP

    • Small Office Network

    • Data Warehouses

    • Medical Diagnostics

    • Process Automation Equipments

    Features• Extended Runtime Capabilities• Flexible (Site Specific) Battery Configuration• Compact Tower design.• Generator Compatible• Class B Electromagnetic interference (EMC)• compatible• Ultra wide input voltage range• High capacity Battery Charger for GXTL • High input power factor & low THDi

    Liebert GXT-MT 1-3kVA UPS

    Liebert GXT-MT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions. It isavailable in adaptable battery architecture & compact tower configuration.

    • Small Research and Functional Laboratories

    Note: Liebert GXT-MT standard model is provided with an internal battery. It is also available in long Back-up mode

  • 13

    Technical Data

    Input system

    Rated voltage

    Voltage range

    Frequency

    Power factor

    Output system

    Power factor

    Voltage

    Line regulation

    Dynamic variation

    Frequency

    Frequency range

    Crest factor

    Bypass Operating Voltage

    Transfer time

    Model

    Electrical

    Rating

    Charging current 1A 4A 1A 8A 1A 8A

    1000VA/700W

    Input

    Output

    Voltage harmonic distortion (rated input voltage, rated input frequency)

    Inverter overload capability (in Normal mode, 25°C)

    Inverter overload capability (in Battery mode, 25°C)

    External battery voltage 36Vdc

    Input THDi

    3000VA/2100W

    DC Component

    96Vdc

    Battery

    Qty x Volts x Capacity 3x12Vx7.2Ah 8x12Vx7.2Ah 8x12Vx7.2AhManufacturer / Model CSB/GP 1272F2 or CSB/GP 1272F2 CSB/HRL 1234W Panasonic or Panasonic F2 or Panasonic Equivalent Equivalent EquivalentTypical Autonomy Time 12 Minutes 15 Minutes 9 MinutesAutonomy at Half Load 20 Minutes 26 Minutes 16 MinutesCharging Duration 80% of battery capacity in 4 hrs (standard type)Noise (within 1m) GXT1000L-MT, GXT2000L-MT, GXT3000L-MT: 150% 300ms

    3:1

    < _6%(0 ~100% non-linear load)

    150% 300ms

    220Vac / 230 Vac / 240 Vac ±2%

  • 14

    Liebert GXT-MT 6/10 kVA UPSFIT - AND - Forget UPS SystemPower Protection AndPower Source

    Liebert GXT-MT 6/10 kVA UPS

    Features•

    Parallel up to 3modules

    Extended Runtime Capabilities

    Compact Tower design

    Generator Compatible

    Class B Electromagnetic interference (EMC)

    compatible (EN50091-2)

    Ultra wide input voltage range

    High capacity Battery Charger for GXTL

    High input power factor & low THDi

    Applications

    • Educational Institutes

    • Small Retail Out lets

    Small & Medium Size Data Center

    Telecommunication, VoIP

    Office Network

    Data Warehouses

    Process Automation EquipmentsLiebert GXT-MT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions.

    This high performance UPS withproven reliability is available in compact tower design

  • 15

    Technical Data

    Input system

    Rated voltage

    Voltage range

    Frequency

    Power factor

    Output system

    Power factor

    Voltage

    Line regulation

    Dynamic variation

    Frequency

    Frequency range

    Crest factor

    Bypass Auto retransfer

    Transfer time

    4.2A

    Capacity 20 nos. of 12V

    Charging duration

    Model

    Electrical

    IP20(static state) Protection

    Rating

    Charging current

    50 / 60 Hz ±0.05Hz

    46-54 Hz

    105% 10sec,

    3:1

    Noise (within 1m)

    < 6%(0 ~100% non-linear load)

    ±5% in 60 ms

    50 Hz

    > 0.98 (conditions: rated voltage, full pure resistive load, fully charged battery)

    1-phase, plus PE

    0.7

    Battery

    6000VA/4200W

    1-phase, plus PE

    Depends on battery capacity

    >130% 1sec, transfer to bypass turnoff output

    220Vac / 230 Vac / 240 Vac ±1%

  • 16

    Liebert GXT- RT 1-3kVA UPS

    Applications

    • Extended Runtime Capabilities

    • Flexible (Site Specific) Battery Configuration

    • Rack / tower Adaptability

    • DSP controlled Online double conversion

    • Generator Compatible

    • “Mute” design

    • Class B Electromagnetic interference (EMC)

    • compatible

    • Ultra wide input voltage range

    • High capacity Battery Charger

    • High input power factor & low THDi

    Features

    Liebert UPStation GXT-RT 1-3kVA UPS

    True Online Double Conversion UPS With Extended Runtime Capabilities With Both Rack & Tower Compatibility

    • Small Size Data Center

    • Telecommunication, VoIP

    • Small Office Network

    • Data Warehouses

    • Medical Diagnostics

    • Process Automation Equipments

    • Small & Medium Functional & Research

    • Laboratories

    Liebert GXT-RT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions.

    It is available in adaptable battery architecture and both rack and tower-mountable configuration to suit your specifications.

  • 17

    Technical Data

    Model GXT1000L-RT GXT2000L-RT GXT3000L-RT

    Rated Out put 1kVA 2kVA 3kVA

    Rectifier type

    Input volta ge

    Input volta ge range

    Input frequenc y range

    Input power factor

    Battery type

    Battery strin g rated voltage 36Vdc 72Vdc 72Vdc

    Inverter type

    Output active power 0.7k W 1.4kW 2.1k W

    Output socket type I E C I E C IEC/Terminals

    Output voltage

    Output frequency

    Output VTHD (Volta ge Total Harmonic

    Load maximum crest factor

    Step load capability

    Efficiency >88% >89% >90%

    Switching time (mains failure )

    Noise

  • 18

    Super 400D (10/20 kVA)True On-line DSP Based UPS With Unity Power Factor

    Applications• Facility-wide networks

    • Medical equipment

    • Industrial processes

    • Large computer rooms

    Features & Benefits

    Temperature compensated Battery

    charging to enhance the Battery life

    Battery test facility

    Reverse Phase sequence operation

    Auto retransfer facility

    DSP and Dual microprocessor based system

    The Liebert Super 400D is a true

    On-line sine wave UPS system that

    provides the user with clean

    computer grade power for

    continuous operation of his critical

    load, regardless of any disturbance

    on the upstream AC power. The

    system offers many innovative

    features to give the user maximum

    reliability and flexibility at the lowest

    operating cost. With Liebert Super

    400D UPS system, you have

    complete peace of mind.

    10,20

    Unity Input Power Factor

    Low Input Current Harmonic Distortion of less than 5%

    Super 400D (10/20 kVA)

  • 19

    Technical Data

    Input Parameters

    Input VoltageInput Voltage Variation Input Frequency Input Frequency Variation Power walk in Power Factor at rated load Operation with Reverse Phase Sequence

    Bypass Supply Voltage

    Nominal DC bus voltagePermissible DC voltage variationDC bus OV tripEnd of discharge DC busTypes of batteries supportedNominal battery float voltageMax. batt.charging currentDC rippleD.C. Voltage Regulation

    Output VoltageFrequencyPower rating at 0.8 p.f.Power rating at 1.0 p.f.Overload Rating

    Max. Non-linear load permissibleOutput Voltage regulationTransient response for 100% load changeRecovery timeFreq. stability unsynchronized -synchronized -Max. rate of change of FrequencyOutput Voltage Distortion

    Transfer time synchronized -unsynchronized -

    Voltage limits for Inv. operationSMF battery Float Charge VoltageMax. Charging current

    Height x Depth x WidthWeightVentilationCable entryColour / Panel finishBase castor wheels

    Operating TemperatureStorage TemperatureRelative HumidityAltitudeTemperature DeratingAltitude Derating

    415V, 3-Phase, 4 wire- 30%, +25 % 50 Hz +/- 10% Progressive over 10 seconds 1.0 (Unity) Possible

    220/ 230/ 240V AC

    356V 260V - 410V 410V 260V SMF 356V 7.0A< 2% rms ± 1%

    220/ 230/ 240 VAC 1 Phase 50 Hz 10 kVA, 20 kVA 8 kW, 16 kW 110 % for 60 minutes 125 % for 10 minutes 150 % for 1 minute100 % with Crest Factor of 3:1 +/- 1% +/- 10% 10 millisecond +/- 0.1 % ± 1Hz, ± 2 Hz, ± 3 Hz 0.2 \0.4 hz/sec < 3 % at Non linear load < 2 % at linear load0 millisecond 20 millisecond

    260V DC to 410V DC 26 Blocks of 12 V each 356 VDC 7.0 A

    1150mm x 650mm x 450mm 275kg Forced - Air cooled Front end - Bottom Structured dark Grey Yes

    o o0 C to 45 C, continuous

    o o0 C to 70 C 95% RH 1000 Meters

    o o1.5% per C between 40 & 50 C 1 % per 100m between 1000m - 2000m

    Bypass Parameters

    DC Parameters

    Output Parameters

    Parameters

    Mechanical Parameters

    Environmental Parameters

  • 20

    Applications

    Features

    Series 7400 M (10/30/40/60 kVA)Maximum Protection For Mission Critical Network Applications

    The Liebert Series 7400 M

    addresses all the power

    quality needs of today’s

    networked economy by

    providing a perfect sinewave

    output voltage with stable

    frequency, over and above

    offering many other

    important customer values.

    Series 7400 M (10/30/40/60 kVA)in Rack and Tower Mode

    •Information TechnologyServers (LAN, WAN, e-mail, ERP, Web, Digital Archives, IntraNet)

    Networking (Routers, Hubs, Switches, Multiplexer, Bundler,

    Unbundler, Modems)

    Banks, Insurance and Financial Services

    Telecommunications, Billing Computers

    Medical Diagnostics, MRI, CT Scan, Cath Lab

    Process Automation, Small processes, Light Robotics

    ••••

    •On-line double conversion UPS: makes your load independent from both main's voltage and frequency.

    Ensures Server-grade high quality of power

    IGBT technology PWM inverter switching technology:

    provides your load with perfect sinewave voltage

    High efficiency performances: lower cost of ownership

    Excellent performance with either 100% unbalanced and

    100% non-linear loads with crest factor upto 3:1 without

    derating: no need to care about the distribution of your

    single phase loads between output phases nor to oversize

    the UPS

    Super-servers, mini-computers and multi-processing systems

    Advanced battery management systems with programmable

    battery testing: constantly monitors the the health of the

    battery pack keeping the battery ready to work for emergency

    situations

    Small footprint and convenient maintenance access: ease

    of positioning and saving of floor-space

    Inverter with high overload capability: no need to oversize

    UPS; reduced initial investment

    Inverter output protected against short-circuit: high

    protection to the inverter hence more availability of the

    systems; Investment protection

    Zero footprint for optional tuned filter for the input: lower

    cost of ownership because of space saving and reduced

    electricity bill

    ••

    ••

  • 21

    Technical Data

    Model 10 30 40 60

    Power 10kVA 30kVA 40kVA 60kVA

    Output Power 8kW 24kW 32kW 48kW

    Power factor 0.8

    Input

    Voltage 380/400/415 V

    Frequency 50 or 60 Hz

    Power Factor > 0.9 (Additional Filter)

    THDi < 10%-15% with Battery charging

    Voltage Window + 10%-20% without battery charging

    Output

    Voltage 380/400/415V

    Frequency 50 or 60 Hz

    Voltage stability

    - static +_ 1%

    - dynamic +_ 5%

    Voltage distortion

    - linear load 1% typical

    - non-linear load 5% max (with 3:1 crest factor)

    Overload capability three-phase: 110% for 60 mins,

    125% for 10 Mins, 50% for 1 min

    Single-phase: 200% for 30 secs

    Maximum permissible non-linear load 100% (with 3:1 crest factor)

    Physical

    Weight 480kg 540kg 620kg

    Width 710mm 710mm 710mm

    Height 1420mm 1420mm 1420mm

    Depth 800mm 800mm 800mm

    20 kVA model also available on request.o oOperating Temperature is 40 C. However ratings can be selected for ambient temperature upto 50 C

  • 22

    True On-Line Sinewave UPS System ForThe Networked Economy

    Applications• Telecommunications Facilities• Data processing• Medical imaging equipment• Industrial process equipment

    • Functional & Research Laboratories

    The Liebert iTrust 3-phase is a true on-line 3 phase UPS system (sine wave output) that provides the user with clean computer grade power for continuous operation of his critical load, regardless of any disturbance on the upstream AC power. The system offers many innovative features to give the user maximum reliability and flexibility at thelowest operating cost. With Liebert iTrust 3-phase UPS system, you have complete peace of mind.

    Liebert iTrust 3-Phase UPS System

    • Parallel for Redundancy or Capacity for up to 4 units• Full Digital Signal Processing using the latest DSP technology• Wide Input Voltage Range• Low Current Harmonic Distortion of less than 3%• High Input Power Factor• High Overload and Short-Circuit Capacities• Intelligent Battery Management• Large LCD Display and Mimic Panel for Real-time information

    Features

    • Large Format Departmental Stores & Multiplexes

    • MTBf over 5,00,000 hrs ensuring reliable power supply• Power supply efficiency over 97% through Bypass during good• mains supply thus minimizing operating cost

    iTrust 3-Phase UPS

  • 23

    Technical Data

    Capacity 30kVA 40kVA 60kVARectifier InputInput Voltage 380/400/415v [line-to-line voltage]AC power input three-phase three-wirePower factor >0.99Harmonic current

  • 24

    Liebert NXNext GenerationUninterruptible PowerSystems

    Applications•Server Rooms and Mid-sized Data Centers

    •Telecommunication (Fixed, WiLL & Mobile) Billing & Reporting

    Systems

    •Networks (LAN, MAN & WAN), InfoCom and WiFi Hot Spots

    •Industrial Process & Motion Automation for Mid-sized plants

    •Medical Diagnostic / Imaging Equipment

    Features•Stratified cooling techniques•Versatile and simultaneous communication facilities•Compact active and passive footprints•Capability to handle 0.9 leading power factor loads•Capability to handle 100% unbalanced loading•Backfeed protection•User f lexibility in selecting effective conÞ guration for the application•Large and user-friendly LCD display in twelve different languages•Compatibility to VRLA (SMF), LATB, Nickel Cadmium batteries•Black start facility

    Benefits• Hi-Availability of Quality Power• Reduced Cost of Ownership• Upstream Green Power• Ease & Simplicity in Scalability & Redundancy• Investment Protection

    Liebert NX – the next generation,true on-line, double conversion digital UPS – is designed to appropriately address the“Hi-Availability Quality Power”need of B2B and B2C businesses.Innovation, simplicity and low costof ownership have been delicatelyconverged in Liebert NX to offeryou the highest capital investment return. With the Liebert NX, you can rest assured that you havehigh nines quality power for yourcritical business applications.

    Liebert NX comes in six popular ratings: 30, 40, 60, 80, 100 & 120 kVA.

    Liebert NX

  • 25

    Technical Data

    Rated Power @ 0.8 PF [kVA] 10 15 20 30 40 60 80 100 120 140 160 200

    Rectifier Type IGBT-based Vector Controlled PFC (PF Corrected)

    Input Voltage [Vac] 380 / 400 / 415 (Accepted from 305 to 477 without batt. Use)

    Input Frequency [Hz] 50 or 60 (Accepted range from 40 to 70)

    Input Current THD

  • 26

    Applications• Facility-wide networks• Medical equipment• Industrial processes-Automation• Transport Automation

    Features

    From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them allefficiently and effectively.

    Hipulse is carefully designed to maximize the availability of your critical loads to ensure that your business is protected to the maximum extent possible against power quality problems as well as complete power failure.

    • On-Line Double Conversion• IGBT-based PWM Inverter• Wide input voltage tolerance (+10/-15%)• Wide input frequency tolerance ( 5%)• Automatic battery testing• Common battery sharing kit (optional) with 1+1 configuration• Built-in maintenance bypass (Single and 1+N Models)• Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA• UPS modules in Dual Bus configuration using optional HiSync on

    the Upstream (with UPS), HiSwitch in the downstream (after UPS) and load-end SmartSwitches

    • Provision to use any type of battery: Wet cells (Tubular or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance free and Nickel Cadmium

    • Field settability of end-cell voltage of the battery• Intelligent web communications and automatic graceful computer

    shutdown operations

    Liebert Hipulse UPS (30-150 kVA 1-Phase)in Rack and Tower Mode

    • N form software for full-scale and cost-effective monitoring• Site scan web solution tool for online monitoring

    • Large Computer Rooms

    Liebert Hipulse UPSDigital UPS For The Digital World & Industrial Automation

  • 27

    Technical Data

    Nominal rating [KVA](0.8 pf) 25 40 60 80 105 130 150

    Depth[mm]

    Width[mm]

    Height[mm] 2110 2110 2110 2110 2110 2110 2110

    Voltage 380/400/415V(+10/-15%)-3ph-3W

    frequency 50 or 60 Hz +/- 5%

    Power factor 0.8-0.92

    Voltage stability 230/1 ph

    Voltage stability -steady state (+/-)1.5%

    100% load Step (+/-) 5%

    Frequency Stability- Synchronized with the bypass supply (+/-)1%

    - Auto -synchronized (+/-) 0.1%

    Overload capacity from inverter at

    nominal voltage 110% for 60 minutes,125% for 10 Minutes,135-150% For 1Minute

    Short circuit current from inverter 1.5 in for 5 seconds(in accordance with EN50091-1-1)

    Voltage distortion with linear load 2% max

    Voltage distortion with 100% Non

    linear load

  • 28

    Applications• Facility-wide networks• Medical equipment• Industrial processes

    Features

    From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them allefficiently and effectively.

    Hipulse is carefully designed to maximize the availability of your critical loads to ensure that your business is protected to the maximum extent possible against power quality problems as well as complete power failure.

    Liebert Hipulse UPS(80-800 kVA 3-Phase)

    Liebert Hipulse UPS (80-800 kVA 3-Phase)in Rack and Tower Mode

    • On-Line Double Conversion• IGBT-based PWM Inverter• Wide input voltage tolerance (+10/-15%)• Wide input frequency tolerance ( 5%)• Automatic battery testing• Common battery sharing kit (optional) with 1+1 configuration• Built-in maintenance bypass (Single and 1+N Models)• Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA• UPS modules in Dual Bus configuration using optional HiSync on

    the Upstream (with UPS), HiSwitch in the downstream (after UPS) and load-end SmartSwitches

    • Provision to use any type of battery: Wet cells (Tubular or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance free and Nickel Cadmium

    • Field settability of end-cell voltage of the battery• Intelligent web communications and automatic graceful computer

    shutdown operations

    Digital UPS For The High-EndDigital World

    • Telecommunication• Data Centers in IT/ ITES/ BPOs• Server & Networking• Entertainment & Media• Server Farms

    • N form software for full-scale and cost-effective monitoring• Site scan web solution tool for online monitoring

  • 29

    Technical Data

    Hipulse UPS System

    Nominal Rating [kVA] (0.8pf) 80 120 160 200 300 400 500 600 800

    Rectifier Type 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p 12p 12p 12p

    Physical Characteristics

    Depth [mm] 875 1000

    Width [mm] 900 1300 1250 1890 1250 1890 1250 1890 1640 2280 2460 2460 3200 3200 4400

    Height [mm] 1900

    Weight [kg] 750 1120 1000 1475 1200 1725 1350 2000 1850 2540 2400 3100 4200 4500 5050

    Input

    Voltage 380/400/415V (+10/-15%) 3Ph 4w

    Frequency 50 or 60 Hz +/-5%

    ITHD 4-10% with optional input filter

    Power Factor 0.90- 0.94 with optional input filter

    Output

    Voltage Stability 380/400/415V 3Ph 4w

    Voltage Stability

    -Steady State +_ 1%

    100% Load Step +_ 5%

    Frequency 50 or 60 Hz

    Frequency Stability

    -Synchronised with the bypass supply +_1%

    - Auto Synchronised +_0.1%

    Overload capacity from inverter at nominal voltage

    -3ph 10% for 60 minutes, 125% for 10 minutes, 135-150% for 1 minute

    -1ph 200% for 30 seconds

    Short circuit current from inverter

    -3ph 1.5 In for 5 seconds 9in accordance with EN 50091-1-1

    - 1 ph 2.9 In for 5 seconds 2.2 In for 5 seconds

    Voltage Distortion With Linear Load

  • 30

    Applications

    Features

    Liebert Precision Power Center

    Liebert Precision Power Center

    Liebert delivers the packaged power solution through precision power center (PCC), creating high quality power to protect the operation of a critical facility. It is a all in one power system at an affordable price that will close the power delivery loop in your critical facility.

    Affordable and reliable operation of PCC ensures that power is distributed properly to each piece of your important equipment and you get maximum safety standards.

    • Computer rooms• LANS/WANS • Communications facilities• Office areas• Medical imaging suits• Grouped workstations• Process control rooms• High-tech manufacturing power sites.

    • Computer-Grade grounding • Handles non linear loads• Online communication tools • Compact single cabinet• Single input cable connections• Easy relocation• Expansion capabilities for future requirement• Onsite power monitoring• Secure distribution and circuit identification• Central monitoring interface• Space saving and easy to install• Optional system enhancement system• Circuit identification.

    Affordable Packaged Power Management For Higher Power Quality

  • 31

    Technical Data

    Precision Power Center

    Output

    KVA 50 75 100 125 150 200 225

    Input

    Voltage 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380

    Input Circuit

    Breaker (Amps) 100 100 100 150 150 150 200 200 200 250 250 250 300 300 300 400 400 400 400 400 400

    Panel Board Poles

    Std 24 24 48 48 72 96 96

    Opt** 96 96 96 96 96 96 96

    Dimensions (cm)

    W 600 600 600 600 800 800 800

    D 1000 1000 1000 1000 1200 1200 1200

    H 2000 2000 2000 2000 2000 2000 2000

    Weight

    Kg 420 520 630 710 860 1045 1110

    Dimensions (cm)

    Output 2.0 2.55 3.3 4.06 4.5 6.0 6.75

    • KVA : 50-225, 3 phase

    • Input : 3 Phase 3-wire plus ground 380, 400 or 415 volts : 50 Hz (Transformer less system require 3 phase, 4w & G)

    • Output : 3-phase, 4-wire plus ground220/380,230/400 or 240/415 volts: 50 Hz

    • Alarm conditions : O/P & under voltages; O/P overload;neutral and ground over currents; o/p voltage THD;

    Transformers over temperature; frequency deviation;phase sequence error; phase loss; 5 customer specifiedalarm conditioning

    • •

    • •• •

    Ground : Single point reference on separately derived system

    Distribution : Individually protected 125 Amps panel board with bolt on breaker and flexible output cables

    Cooling system : convection / forced

    Monitored parameters : I/P & O/P Voltages; o/p, Neutral & grounded currents / P voltage THD; K& crest factor; KVA;KW; PF; % load; KW Hrs; frequency; o/p current THD

    Efficiency : 96-98%

    Voltage Adjustment : 10% to + 5% of nominal in 2 ½ %increments

    • •

  • 32

    Liebert Powersure PanelTransient Voltage SurgeSuppressor

    Applications

    •Telecommunications and broadcasting Voice and data networks as well as television and radio

    broadcasters rely on high quality power for f lawlesstransmission.

    •Industrial electronics Factories require noise free voltage to keep process control

    machines running at maximum productivity with minimum downtime.

    •Computer equipment and networks Office, shops, superstores and other retail businesses need clean power to maintain the integrity of computers and data.•Telecommunications switchgear and cellular facilities

    Reliable power is essential to ensure networks work reliably, 24 hours a day.

    •Hospitals Closely controlled power is essential in critical areas such as

    operating theatres and intensive care.

    Liebert Powersure Panel utilizesPatent pending circuitry to monitorthe status of all protection modes,Including neutral to ground. Should protection be unavailable in any mode, the green LED will be out,and the red LED will illuminate andan audible alarm will sound. In addition, high isolation form C drycontacts for remote monitoringprovide indication of: suppressionsystem failure, under voltage, andphase or power loss. LiebertPowersure’s patent pending Suppression Integrity monitoringIndicates failure for both shorted oropened suppression components.

    For Unparalleled Protection That Exceeds Industry Standards...

    The Liebert Powersure Panel incorporates proven technology toprovide unparalleled protection from transient surges and electricalline noise (ELN).

    Liebert Powersure Panel

  • 33

    Features

    • Compact module attaches directly to breaker panel• CE marked, complies with EMC and low voltage directives• Patent Pending Powersure Detection Circuitry• Easy, safe, maintenance free operation• Repeatable surge current capability• Can be retrofitted to existing panel boards• High isolation dry contacts for remote monitoring• Designed for maximum safety• 5 Year warranty

    The Powersure Series At a Glance

    • Connection means: Parallel connectedAgency listings: UL1449, Ul1283, CSA, CE,

    BS6651 • Protection modes: All modes standard (L-N, L-G,

    N-G, L-L); optional-any combinationEMI/RFI Attenuation: 60dB typical

    • Response time: Less than .5ns• Operating Frequency: 47/63 Hz• Enclosure: Gray Noryl HS-1000, Rated 94-5V,

    Nema, 12, 4, 4X, IP65, IP66Fault Current Rating: 300,000 AIC

    • Line frequency: 47-63 Hertz• Temperature: -40 to +60 degrees C

    Relative humidity: 0 to 95% noncondensingAltitude: 0 to 5500m

    • Audible noise: Less than 45 dBa

    Technical Data

    Lower Exposure Medium Exposure

    Connection Type Parallel Parallel

    Operating Voltage Range -15% -15%

    Surge Current Capacity 25kA, 50kA or 100kA 100kA or 160kA

    Fault Current Rating ( A/C ) 14kA/C 65kA/C

    Dimensions 4.72”x4.72”x2.36” (160 kA units) 8”x6”x4”

    (100 kA units) 6”x4”x3”

    Operating Frequency Range 47…63 Hz 47…63 Hz

    Capacity Continuous Continuous

    EMI/RFI Attenuation 40 dB typical 40 dB typical

    Response Time

  • 34

    ASCO SwitchDesigned To MinimizeDowntime On CriticalSystems

    Applications•Healthcare Facilities•Commercial Buildings / Industrial Buildings•Web Hosting, Internet Data Centers•Telecom Central Offices•Process Manufacturing / Wafer Fabrication Plants / Distributed Power / Load Management

    ASCO Switches are the standard of the industry. High speed transfer of loads between alternate sources of power, regardless of ampacitysize, is achieved by a reliable, Field proven solenoidoperating mechanism. When combined with a programmable microprocessor controller with keypad and LCD display, they offer the most advanced method of transferring all types of loads, such as motors, electronic drives, UPSs and microprocessor based systems.

    7000 Series Power Transfer Switches are available open or enclosed, in ampacity sizes from 30 through 4000 amperes with the largest selection of optional accessories offered anywhere. All switching Configurations are available with an integrally mounted bypass- isolation switch and/ or rated for use in service entrance applications .

    ASCO 7000 Series

  • 35

    Applications•Healthcare Facilities•Commercial Buildings / Industrial Buildings•Web Hosting, Internet Data Centers•Telecom Central Offices

    Features•The Series 300 is listed to UL 1008 standard for Transfer Switch Equipment and CSA standard C22.2 for

    automatic transfer switches.•Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code (NEC) Articles

    700, 701 and 702.•30 through 3000 amps in a compact design, Available to 600 VAC, single or three phase. of loads, such as motors,•Rated up to 600 VAC, 30 through 4000 amperes.•True double- throw operation: The single solenoid design is inherently locked and prevents contacts from stopping between sources or from being in contact with both sources at the same time.•High withstand and close- on ratings•There’s no danger of the Series 300 ATS transferring loads to a dead source because the unique ASCO single- solenoid operator derives power to operate from the source to which the load is being transferred.•Solid, switched, or overlapping neutral conductor options.•Easy- to- read flush- mounted control and display panel provides LED indicators for switch position and

    source availability.•It also includes test and time- delay bypass switches as standard features.•Standard engine exerciser for weekly automatic testing of engine generator set with or without load.•Adjustable time- delay feature•Supplied with solid neutral termination.•Standard ground conductor connections.•Optional switched neutral pole available.•Accessory kits available.•Meets IEC 60947-6-1

    The ASCO Series 300 was designed for one purpose— to automatically transfer critical loads in the event of a power outage. The rugged construction and proven performance of the ASCO Series 300 assure the user of many years of complete reliability. The Series 300 is even designed to handle the extraordinary demands placed on the switch when starting or restarting stalled motors and switching high inrush loads.

    ASCO Series 300

  • 36

    Emerson NetworkPower Is the OneCompany That CanProvide A CompleteRange Of PowerProtection SolutionsDesigned For AnyFacility And Any Need

    Poor power can affect every aspect of your criticaloperations. Critical equipment and processesthroughout your operations can be affected by poorpower quality, outages and other related problems.

    Without Proper Power, Vital Processes JustCannot Function

    Important computing, communications and industrialprocess control functions all depend on clean, continuouspower to maintain these operations. From a single desktopPC to a large data center, power quality is the commondenominator that must be maintained.

    Differing Needs Require Different Solutions

    Different parts of your operation have different needs forpower. Depending on the nature of the operation, powerneeds can range from simple surge protection all the wayup to redundant UPS systems and power feeds with back-up generating capabilities.

    Threats To Your System’s Availability AreAround Every Corner

    There are a number of points within a critical facility wherepower troubles can develop. Adding to this dilemma is thatoperations in one part of your facility can adversely affectthe power in another area of the building. Yourproductivity depends on critical electronic systems – canyou depend on your power to keep them operatingproperly?

  • 37

    Remote FacilitiesEmerson Network Power’s High-reliability Liebert UPSsystems and DC power equipment are critical tomaintaining operations in telecommunications sheltersand other unmanned structures.

    Telecommunications RoomsEmerson Network Power can provide a reliable flow of bothAC and DC power for telephone switching systems andother communications equipment.

    Equipment Rack EnclosuresThese densely-packed equipment bays, housing servers orother essential communications devices require UPS back-upplus distribution to get uninterrupted, conditioned power toeach and every component in the rack.

    Computer RoomsEmerson Network Power offers the full range of UPS,distribution systems and other power protection equipmentto meet the needs of the largest data centers and networkingfacilities.

    Office LocationsWith many mission-critical computing systems locatedright in the office space, there is a need for UPS protectionthat can be placed nearby. Liebert offers a number of powersystems that are especially designed for use in business andoffice environments.

    Process Control RoomsEmerson Network Power’s Liebert UPS, surge protectionand power distribution are all key to maintaining theproper operation of process control and othermanufacturing systems that utilize microprocessor andcomputer control.

    A Power ProtectionSolution ForEvery Need

  • 38

    Our End to End Solutions

  • 39

    Power Is Just Part of The Reliability Story

    Liebert Also Offers A Full Range Of Heat Removal Solutions

    In addition to proper power, sensitive electronic computer and communications systems also require the correct environment in order to function reliably. Because this equipment produces heat, it is absolutely necessary to control and maintain the temperature and humidity levels where it is located in order to assure continuous operation.

    The Widest Range Of Products Gives You An Infinite Range Of SolutionsAs network equipment gets smaller and packed tighter, it creates unprecedented heat densities that can result in thermal shutdown or total component failure. Precision air conditioning, specialized enclosures and rugged remote protection can assure network uptime against this threat.

    From high-capacity units to compact above-ceiling systems there is a Liebert system designed to cool and protect your critical computing systems. We make the industry’s widest range of precision environmental control, including air conditioners, fluid chillers and heat rejection systems in capacities from one to more than 65 tons. These systems are available with a choice of cooling methods, including chilled water, air cooled and glycol cooled models, as well as ultra energy efficient GLYCOOL™ and Dual-Cool configurations.

    We also offer specialized systems, including exterior mounted air-conditioning for telecommunications enclosures, supplemental cooling for high-density electronic applications.

    End to EndSystem SolutionsWith EmersonNetwork Power

  • 24

    Emerson NetworkPowerGlobal Services

    FACTORY TRAINEDYou can be sure that the only people who deal with your Critical Air Equipment will be 100% Factory Trained Emerson Service Experts

    ORIGINAL PARTSYou can be sure that the parts you will receive from our 100% Emerson Service Experts are 100% Original Parts. With our multi-tiered parts availability program, you are ensured that parts will be made available to you when and where you need them.

    VERSION CONTROLYou are assured of 100% Version Control so that your critical business systems won’t have to experience downtime due to incompatibility.

    SUPPORT NETWORKWe not only help you develop you Environmental Control System, but our 100% Emerson Service Experts also offer a Full Support Network so that your critical systems have a 100% Safety Net every step of the way.

    QUALITY RESPONSEWe know it is important to get to your critical systems on time. With our 100% Emerson Service Experts you don’t just get prompt service; you also get 100% Quality Response. This means no useless tinkering, no wasted time-- just Quality Service, straight away.

    100% Emerson Service Experts.Would you settle for anything less?

  • 41

    Our Capability Literally Extends From “Grid to Chip”, Offering The Broadest Range of Solutions To The Market.

    Emerson Network Power offers:

    • DC Power Systems (Small, Medium, and Large Systems)

    • Uninterruptible Power Systems (from 500VA to 1000 kVA)

    • Precision Air Conditioning for Computer Rooms

    • Automatic Transfer Switches Medium and Low Voltage

    • Static Switches

    • Shelter Air Conditioning for Telecommunications

    • Specialized Enclosures to protect Critical Network Equipment

    • Surge Suppression and Filtering

    • Site Monitoring Equipment

    • All Operating System associated Software

    • Emerson Network Power Global Services (24X7X365 support for all our customers)

    Our PortfolioShapes OurSolutions

  • Emerson Network Power.

    While every precaution has been taken to ensure accuracy and completeness in this brochure, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

    Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2008 Emerson Electric Co.

    TMThe global leader in enabling Business-Critical Continuity .

    Voice of Customers UPS Awards 2006-07 for Product Line& Customer Service Awards in IT, Telecom,

    Large Enterprise & Hospitals andCustomer Service Leadership Award in BFSI

    Best IT Hardware CompanyMaharashtra IT Award 2006-07

    2007R

    Emerson Network Power1050, Dearborn Drive, P. O. Box: 29186Columbus, Ohio - 43229Tel.: 800.877.9222 (US & Canada Only)Tel.: 614.888.0246 (Outside US)Fax: 614.841.6022

    Country OfficeEmerson Network Power (India) Private Ltd.Plot No. C-20, Road No. 19, Wagle Estate,Thane (w), Maharashtra - 400 604. India.Tel.: 91-22-67208000Fax: 91-22-25828358

    City Offices

    East ZoneKolkata : 033-40023100Jamshedpur : 0657-2227678Guwahati : 0361-2734486Bhubaneshwar : 0674-2586003/3299872

    South ZoneBangalore : 080-41135670/770/870Secunderabad : 040- 27806771/772Cochin : 0484-2341985/86Chennai : 044-28151063/28152596Vishakapatnam : 0891-2505540/41/42Coimbatore : 0422-4387625

    West ZoneGhatkopar : 022-67208800/67209000Pune : 020-66235000Baroda : 0265-2314296/2330383Nagpur : 0712-5634997Indore : 0731-4023806Ahmedabad : 079-27560230/40Vikhroli : 022-40780303

    North ZoneNew Delhi : Chandigarh : 0172-5077531Lucknow : 0522-2237174

    011-28753214/0774/2218

    Gurgaon : 012-4470015/16/17Jaipur : 0141-4024774

    Outside Plant

    Power Switching & Controls

    Precision Cooling

    www.emersonnetworkpower.co.in

    Racks & Integrated Cabinets

    Services

    Surge Protection

    Embedded Computing

    Embedded Power

    Monitoring

    AC Power

    Connectivity

    DC Power

    Page 1Page 2Page 3Page 4Page 5Page 6Page 7Page 8Page 9Page 10Page 11Page 12Page 13Page 14Page 15Page 16Page 17Page 18Page 19Page 20Page 21Page 22Page 23Page 24Page 25Page 26Page 27Page 28Page 29Page 30Page 31Page 32Page 33Page 34Page 35Page 36Page 37Page 38Page 39Page 40Page 41Page 42Page 43Page 44