Power Protection for Business-Critical Continuity
Tailored Solutions for Power Protection
-
Trouble is Coming Down The LineAnd You Must BePrepared
Every operation in your business depends upon the instant, around-the clock availability of computers, servers and other electronic systems. If they aren’t working, neither is your company.
Unfortunately, every piece of this equipment your company possesses is subject to the whims of the electricity that powers it.
The first step in taking control of this situation is to understand the threats to your system reliability — and exactly what you can do about them.
The Ability ToTailor a PowerSolution Is WhatSets EmersonNetwork Power Apart
We Know The Importance Of Achieving Protection For Today…And Planning For TomorrowThe decisions you make now are going to impact your ability to efficiently grow into the future. As a power partner that truly understands the importance of genuine reliability, we can implement the best way to achieve it for your operations. Based on our years of experience, we know and understand your current needs for protection — and what it will take to increase your power capabilities as these demands grow. We can help you protect data, hardware and system availability in any combination.
No Matter How Deep Your Protection Needs To Be, We Have The Expertise To Make It HappenWe recognize that not everyone requires the same level of power protection. Liebert has the knowledge of critical facilities and equipment that is necessary to determine the exact needs of each application. An extensive range of power protection choices then enables us to match our equipment precisely to these parameters rather than force-fitting a few products to every situation. The result is our unique ability to deliver power solutions that are always on target for the depth of protection specified.
-
No Organization In The Power Protection Business Has More Real-World Experience Than Emerson Network Power
Many years of experience allow us to properly respond to any power problem scenario. Our resources include knowledgeable leadership, as well as an outstanding staff of research, design, application and service engineers using the latest technological tools.
But the biggest difference in the way we approach your power requirements is the local Liebert Representative, Distributor or Reseller. We are the only company in this business that maintains such a strong local presence on a national and international basis. Specifying and maintaining a high availability power system requires someone who is knowledgeable in all phases of critical systems protection. This resource, coupled with our broad product line, gives Liebert the ability to create a “tailored solution” that will meet your protection needs precisely and efficiently. We don’t have to take the one or two items we happen to have and stretch them to come up with the answer. We give you the best answer every time.
Only Liebert can bring together all of the power protection solutions you need to create system availability that is as close to 100% reliability as possible.
There Is A Liebert Power Solution To Meet Every NeedNo one offers a more comprehensive selection of power products for critical applications than Liebert.
Liebert PS (400 VA/600 VA) 4-5A Reliable Power Protection For Your PC
Liebert Series 7400 M (10/30/40/60 kVA) 20-21Maximum Protection ForMission Critical Network Applications
Liebert iTrust 3-Phase UPS System 22-23True On-Line Sinewave UPS System ForThe Networked Economy
Liebert NX Series 24-25
The Next Generation UPS System
Liebert Hipulse UPS (30-150 kVA 1-Phase) 26-27
Digital UPS For The Digital World & Industrial Automation
Liebert Hipulse UPS (80-800 kVA 3-Phase) 28-29
Digital UPS For The High-End Digital World
ASCO Switch 34-35
Designed To Minimize Downtime OnCritical Systems
Liebert Powersure Panel 32-33
Transient Voltage Surge Supressor
Liebert ITON 600 VA /1000 VA 6-7
A Reliable Power Protection And Backup Solution For Your PC
TMLiebert UPStation GXT 2U 1 /2 /3 8-9
True Online Double Conversion UPS to Keep Your Business Up and Running
True On-line DSP Based UPS With Unity Power Factor
Liebert Super 400D (10/20 kVA) 18-19
Liebert Precision Power Center 30-31
Affordable Packaged Power ManagementFor Higher Power Quality
TMLiebert UPStation GXT 2 (4.5 kVA / 6 kVA) Series 10-11
The New Shape Of Network Power Protection
TMLiebert UPStation GXT-MT 1-2-3 kVA UPS 12-13
True Online Double Conversion UPS with Extended Runtime Capability
TMLiebert UPStation GXT-MT 6 /10 kVA UPS 14-15
Fit-And-Forget UPS System Power Protection And Power Source
TMLiebert UPStation GXT RT 1-3 kVA UPS 16-17
True Online Double Conversion UPS with Extended Runtime Capabilities with Rack & Tower Compatibility
-
2
You Face ManyChallenges in the Pursuit of Uptime
Is There Really A Problem?“My computer can ride right through a short blip in the power — why do I need anything else?”
There Are No Simple Solutions“I have people telling me all I need to do is plug each workstation into a small UPS from the computer store . That’s good enough, isn’t it?”
Different Needs Require Different Power Protection
Configurations“Should I have a small UPS for each workstation or have everything on one large system . Which is best for my facility?”
A Lot Can Happen Between Your UPS And The Equipment
It Is Protecting“We have dozens of pieces of networking equipment. How can I make sure that each one is getting exactly the power it needs?”
Every Wire Carries The Potential For Trouble“An electrical surge came in through an outside phone line and knocked out our entire communications system. Is this going to happen again?”
A Single Source Of Power Simply May Not Be Enough“Adding a second power feed would certainly enhance our availability picture — but who can we talk to about getting it done right?”
-
3
But There AreReal Solutions
You Need Protection From All Power ProblemsAn outage is just the problem you can see. There are many other more frequent power fluctuations — surges, spikes, sags — that you don’t see. Theseare the conditions that cause the “unexplained” lock-ups.
“Out-Of-The-Box” Can Put You Out Of BusinessBuying a simple off-line UPS down at the computer store may be a good solution for your home PC, but it just doesn’t make sense when your business and productivity are on the line. Protecting critical network and computing systems requires the expertise of someone who understands all the risks you face from poor power quality problems with critical equipment.
Centralized Vs. Distributed UPS ProtectionLiebert has the breadth of products that allows you to implement either a centralized or a one-on-one distributed power protection strategy depending on your requirements. Whatever configuration you choose, you can count on Liebert to make it the best it can be. Benefits, suchas increased system security, more efficient maintenanceand improved reliability, make a centralized strategy a better choice for larger operations.
Proper Power Depends On Proper DistributionIn network applications, there may be hundreds of different loads with various voltage requirements, a mix of AC and DC power, plus any number of other electrical Specifications This calls for adistribution system that is designed to maintain the highest levels of reliability and quality between the source of conditioned power and the protected equipment.
Power Conditioning And Surge Protection Throughout The FacilityRaw utility power is often far too “dirty” for sensitive systems, resulting in lost,or garbled data, unexpected software glitches or shutdowns, even hardware damage. The IEEE recommended practice is to install transient voltage surge suppression (TVSS) protection on every electrical conductor that penetrates a facility shell, including power lines, telephone and other communications links.
Maximum Reliability Demands Dual Power SourcesIf your needs require the highest level of system availability, Liebert has the knowledge and products to implement a dual-power strategy throughout your enterprise. UPS, transfer switching, power distribution and other equipment are all brought together to create the ultimate in reliability.
-
4
Liebert PSA Reliable Power Protection For Your PC
Applications• TFT Monitors
• Personal Computers
• Printers
• Modems
• Routers
• Wireless Devices
• Non-critical passive devices
• Standalone Computers
Features• High Frequency Charger Design
• Input Fuse Protected
• Black Start Mode Available
• Separate Low Charge &
• Battery Indicator in AC mode
• Overload, Discharge
• and Overcharge Protection
• Output Cable Provided
Liebert PS (400 VA/600 VA)
A high-performance UPS designed especially to protect low voltage applications and is available in tower design
The Liebert PS' features and flexibility makes it the optimal solution for your small electronic devices both at home and office.
-
5
Technical Data
Liebert PSA 400 Liebert PSA 600
VA/W
Voltage
Voltage Range
Voltage
Voltage Regulation(Batt.
Mode)
Frequency
Frequency Regulation
(Batt. Mode)
Output Waveform
Battery Type & Number
Back up Time (at a PC
load with 15" monitor) 5 minutes 8 minutes
Recharge Time
Typical
Green LED flashing every second
Red LED flashing every 2 seconds for 30
seconds
AC Mode
Battery Mode
Low Battery at Battery
Mode
Fault
Battery Weak at AC Mode
Battery Fault at AC
Mode Red LED flashing three times every 2 seconds
Sounding every second
Sounding every 2 seconds for 30 seconds
Battery Mode
Low Battery at Battery
Mode
Fault
Battery Weak at AC Mode
Battery Fault at AC
Mode Sounding three times every 2 seconds
Full Protection
Dimension, DXWXH (mm)
176.5x80x230
Net Weight (kgs)
Operating Environment
Noise Level
MODEL
CAPACITY
INPUT
OUTPUT
BATTERY
TRANSFER TIME
INDICATOR
AUDIBLE ALARM
PROTECTION
PHYSICAL
ENVIRONMENT
Continuously s ounding
400VA/200W 600VA/300W
220/230/240VAC
170-270VAC
220/230/240VAC
50Hz
Modified Sinewave
2-6ms
+/-1 Hz
±10%
12V/7AH x 1pc 12V/4.5Ah x 1pc
10 hours to 90% after complete discharge
Green LED lighting
Green LED flashing every 4 seconds
Red LED lighting
Sounding every 4 seconds
3.1 3.3
0- 40°C, 0-90 % relative humidity (noncondensing)
Less than 40dB
Discharge, overcharge, and overload protection
-
6
Liebert ITONA Reliable Power Protection And Backup Solution For Your PC
Applications
Liebert ITON 600/1000
Features
A • uto
n est• sta R art
•
•
•
•
•
•
p eSlee Mod
I
r pr t o f r F / ePowe otec i n o ax Mod m
art n i g SSm Mo itor n oftware
art i r o s o o lSm M c opr ce s r c ntro
m rt echn loS a AVR T o gy
o i a o PoC mmun c ti n rt
v lo o ec n O er ad Pr t tio and alarm
• Home PC
• Printers
• Clustered network equipment: hubs, routers, bridges
• Remote telecommunications units
• Desktop Speakers
• Office Telecommunications systems
• Voicemail and e-mail servers
• Test and diagnostic equipment
A best-in-class UPS with proven reliability. ITON is an uptime solution for your personal computers & peripherals and is available in a compact tower design
A line interactive UPS that provides perfect power protection for Small Office & Home Office (SOHO) PC Systems
• Chargers
• Telecom Ports
-
7
Technical Data
MODEL ITON 600 ITON 1000 CAPACITY VA/W 600 VA/360W 1000VA/600W
Voltage Range 140-300 VAC 160-270V
INPUT
Frequency 45-65 Hz (Auto sensing)
Voltage 230V
(Batt. Mode) Voltage Regulation
+/- 10% +/- 5%
Frequency 50Hz 50Hz or 60Hz
(Batt. Mode) Frequency Regulation
+/- 1Hz
Output Waveform Stepped Waveform
OUTPUT
Overload 110% for 5 minutes as “Mains” mode
Battery Type & Number 12V/7AH — 1 PC 12V/7AH — 2 Pcs Backup Time* (As per the loads)
15-22* mins 30 min typical* (with 1 PC)
BATTERY
Recharge Time 8 hours to 90% after complete discharge
TRANSFER TIME
Typical 4-8 ms 4-6 ms
INDICATOR (LED Bar Graph)
AC Mode Green Lighting
The 1st green lighting; The Green 2nd to 5th green gradually
Lighting lighting indicating load capacity
Backup Mode Green flashing Green
flashing
The 1st green flashing; The 2nd to 5th green gradually lighting indicating batteries capacity
Fault The red lighting
Backup Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0.5 seconds Battery Replacement Soundingevery 2 seconds
AUDIBLE ALARM
Fault Continuously Sounding
PROTECTION Full Protection Discharge, overcharge, and overload protection
PHYSICAL
ENVIRONMENT
Dimension (mm), DxWxH 330x100x140 369x141x181 Net Weight 6 kg 13.5 kg
Operating Environment 0-40 C, 0-90% relative humidity
(non-condensing) Noise Level Less than 40 dB
INTERFACE
RS-232 Support Windows 98/NT/ME/2000/2003/ XP, Linux, HP-UX, IBM AIX,
Sun Solaris, Unixware, Free BSD, Mac OS and Compaq True
-
8
Liebert GXT 2UTrue Online Double Conversion UPSTo Keep Your Business Up And Running
Features• True on-line design
• Configurable as rack or tower
• Wide input voltage window allows• UPS support without going to battery,• extending systems availability
• Built-in Surge Suppression
• User replaceable batteries without• removing GXT 2U from rack
• Compatible with new SNMP / Web Card
• Compatible with Multiport 4 or 8
• Compatible with RelayCard INT
• Compatible with MultiLink
A high-performance UPS with proven reliability, custom configurability, hot-swap internal batteries and extendible runtime in a compact tower design.
The GXT2 features and flexibility make it the optimalsolution for small server room,networking and telecomapplications that requirereliable, continuous andquality power.
• LAN and WAN servers
• Clustered network equipment: hubs, routers, bridges
• Remote telecommunications units
• Office Telecommunications systems
• Voicemail and e-mail servers
• Test and diagnostic equipment
• Engineering network servers
• Factory floor protection of micro processor controlled equipment
• Mission critical devices
Applications
TMUPStation GXT 2U in Rack and Tower Mode
-
9
Technical Data
Description 1 kVA 2 kVA 3 kVAUPStation GXT 2U UPStation GXT 2U UPStation GXT 2U1000 2000 3000
Input Parameters
Nominal Voltage 230 VAC
Voltage Range 119 - 280VAC ( Load Dependent )
Frequency Range 40 Hz - 70 Hz
Power Factor > 0.97
Output Parameters
Capacity 1 kVA / 0.7 kW 2kVA / 1.4 kW 3kVA / 2.1 kW
Voltage User Configurable 200 / 208 / 220 / 230 / 240 VAC
Voltage Regulation + / - 3% Steady state
+ / - 5% if synchronized to mains,
Frequency Regulation + / - 0.1 Hz free running or on battery operation ( when not synchronized to mains )
THD
-
10
A high-performance UPS with proven reliability, custom configurability,hot-swap internal batteries and extendible runtime in a compact rack and tower design.
The GXT2 features and flexibility make it the optimalsolution for your small & medium server, data room, networking and telecom applications that require reliable, continuous and
Liebert GXT 2 (4.5 kVA / 6 kVA)The New Shape Of Network And Power Protection
Applications• LAN and WAN servers• Clustered network equipment: hubs, routers, bridges• Remote telecommunications units• Office Telecommunications systems• Voicemail and e-mail servers• Test and diagnostic equipment• Engineering network servers• Factory floor protection of micro processor controlled equipment• Mission critical devices
Features• True on-line design• Built-in PFC circuit• Wide input voltage window allows• UPS support without going to battery,• extending systems availability• Builtin Surge Suppression• Compatible with new SNMP / Web Card• Compatible with Multiport 4 or 8• Compatible with RelayCard INT• Compatible with MultiLink• External plug and play Battery cabinets available• Configurable as rack or tower Other product features of the Liebert GXT2 include• Self-diagnostics• Built-in serial communications for use with Liebert • TMMultiLink Automated Shutdown Software• TMIntellislot communications port• Built-in closure signals• Includes Windows-based configuration program
TMUPStation GXT 2 (4.5 kVA / 6 kVA)in Rack and Tower Mode
quality power.
-
11
Technical Data
Output Ratings
Output Power 4.5 KVA/3.15Kw, 6 KVA/4.2KwNominal Output Voltage 230 VACOutput Voltage Regulation +/-2%Output Voltage Distortion-With 100% Linear Load < 3%Nominal Output Frequency 50 HzOutput Frequency Tolerance 46.5 Hz to 53.5Hz( Phase locked with Mains ) +/-3.5 Hz Synchronized to mainsOverload at 0.7 pf( Load is transferred to Bypass 125% for 10 SecAfter pre-determined timeLoad Power Factor Range 0.7 lagging to unity
Input Ratings
Nominal Input Voltage 220/230/240 VACPermissible Input VoltageVariation at Full Load 176-276 VACNominal Input Frequency 50 HzPermissible Input FrequencyVariation 40 to 70 HzPower Factor at Full load > 0.97
Battery Details (External)
Nominal DC Bus Voltage 240 VDCNumber of Blocks of SMFBatteries 20 blocks of 12 V eachTypes of Batteries Supported Sealed Maintenance Free (SMF)Recharge Time up to 100% Capacity 10 hours to 12 hours
Physical Parameters
Width X Depth X Height (mm) 221x547x430Weight 67 kg
Environmental Parameters
oOperating Temperature at Rated Load 0 to 40 CoStorage Temperature - 15 to + 50 C
Relative Humidity 0 to 95% RHNoise < 55 dB
Agency
Safety EN62040-1-1, TUV/GSRFI / EMI AS 62040-2, EN 50091-2, Class A CE EMC DirectiveSurge Immunity EN 61000 4-5 Level 3 criteria ATransportation ISTA Procedure 1B
-
12
Liebert GXT-MT 1-3kVA UPSTrue Online Double Conversion UPS With Extended Runtime Capabilities
Applications• Small Size Data Center
• Telecommunication, VoIP
• Small Office Network
• Data Warehouses
• Medical Diagnostics
• Process Automation Equipments
Features• Extended Runtime Capabilities• Flexible (Site Specific) Battery Configuration• Compact Tower design.• Generator Compatible• Class B Electromagnetic interference (EMC)• compatible• Ultra wide input voltage range• High capacity Battery Charger for GXTL • High input power factor & low THDi
Liebert GXT-MT 1-3kVA UPS
Liebert GXT-MT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions. It isavailable in adaptable battery architecture & compact tower configuration.
• Small Research and Functional Laboratories
Note: Liebert GXT-MT standard model is provided with an internal battery. It is also available in long Back-up mode
-
13
Technical Data
Input system
Rated voltage
Voltage range
Frequency
Power factor
Output system
Power factor
Voltage
Line regulation
Dynamic variation
Frequency
Frequency range
Crest factor
Bypass Operating Voltage
Transfer time
Model
Electrical
Rating
Charging current 1A 4A 1A 8A 1A 8A
1000VA/700W
Input
Output
Voltage harmonic distortion (rated input voltage, rated input frequency)
Inverter overload capability (in Normal mode, 25°C)
Inverter overload capability (in Battery mode, 25°C)
External battery voltage 36Vdc
Input THDi
3000VA/2100W
DC Component
96Vdc
Battery
Qty x Volts x Capacity 3x12Vx7.2Ah 8x12Vx7.2Ah 8x12Vx7.2AhManufacturer / Model CSB/GP 1272F2 or CSB/GP 1272F2 CSB/HRL 1234W Panasonic or Panasonic F2 or Panasonic Equivalent Equivalent EquivalentTypical Autonomy Time 12 Minutes 15 Minutes 9 MinutesAutonomy at Half Load 20 Minutes 26 Minutes 16 MinutesCharging Duration 80% of battery capacity in 4 hrs (standard type)Noise (within 1m) GXT1000L-MT, GXT2000L-MT, GXT3000L-MT: 150% 300ms
3:1
< _6%(0 ~100% non-linear load)
150% 300ms
220Vac / 230 Vac / 240 Vac ±2%
-
14
Liebert GXT-MT 6/10 kVA UPSFIT - AND - Forget UPS SystemPower Protection AndPower Source
Liebert GXT-MT 6/10 kVA UPS
Features•
•
•
•
•
•
•
•
•
Parallel up to 3modules
Extended Runtime Capabilities
Compact Tower design
Generator Compatible
Class B Electromagnetic interference (EMC)
compatible (EN50091-2)
Ultra wide input voltage range
High capacity Battery Charger for GXTL
High input power factor & low THDi
Applications
•
•
•
•
•
• Educational Institutes
• Small Retail Out lets
Small & Medium Size Data Center
Telecommunication, VoIP
Office Network
Data Warehouses
Process Automation EquipmentsLiebert GXT-MT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions.
This high performance UPS withproven reliability is available in compact tower design
-
15
Technical Data
Input system
Rated voltage
Voltage range
Frequency
Power factor
Output system
Power factor
Voltage
Line regulation
Dynamic variation
Frequency
Frequency range
Crest factor
Bypass Auto retransfer
Transfer time
4.2A
Capacity 20 nos. of 12V
Charging duration
Model
Electrical
IP20(static state) Protection
Rating
Charging current
50 / 60 Hz ±0.05Hz
46-54 Hz
105% 10sec,
3:1
Noise (within 1m)
< 6%(0 ~100% non-linear load)
±5% in 60 ms
50 Hz
> 0.98 (conditions: rated voltage, full pure resistive load, fully charged battery)
1-phase, plus PE
0.7
Battery
6000VA/4200W
1-phase, plus PE
Depends on battery capacity
>130% 1sec, transfer to bypass turnoff output
220Vac / 230 Vac / 240 Vac ±1%
-
16
Liebert GXT- RT 1-3kVA UPS
Applications
• Extended Runtime Capabilities
• Flexible (Site Specific) Battery Configuration
• Rack / tower Adaptability
• DSP controlled Online double conversion
• Generator Compatible
• “Mute” design
• Class B Electromagnetic interference (EMC)
• compatible
• Ultra wide input voltage range
• High capacity Battery Charger
• High input power factor & low THDi
Features
Liebert UPStation GXT-RT 1-3kVA UPS
True Online Double Conversion UPS With Extended Runtime Capabilities With Both Rack & Tower Compatibility
• Small Size Data Center
• Telecommunication, VoIP
• Small Office Network
• Data Warehouses
• Medical Diagnostics
• Process Automation Equipments
• Small & Medium Functional & Research
• Laboratories
Liebert GXT-RT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, besides offering intelligent monitoring and network management functions.
It is available in adaptable battery architecture and both rack and tower-mountable configuration to suit your specifications.
-
17
Technical Data
Model GXT1000L-RT GXT2000L-RT GXT3000L-RT
Rated Out put 1kVA 2kVA 3kVA
Rectifier type
Input volta ge
Input volta ge range
Input frequenc y range
Input power factor
Battery type
Battery strin g rated voltage 36Vdc 72Vdc 72Vdc
Inverter type
Output active power 0.7k W 1.4kW 2.1k W
Output socket type I E C I E C IEC/Terminals
Output voltage
Output frequency
Output VTHD (Volta ge Total Harmonic
Load maximum crest factor
Step load capability
Efficiency >88% >89% >90%
Switching time (mains failure )
Noise
-
18
Super 400D (10/20 kVA)True On-line DSP Based UPS With Unity Power Factor
Applications• Facility-wide networks
• Medical equipment
• Industrial processes
• Large computer rooms
Features & Benefits
Temperature compensated Battery
charging to enhance the Battery life
Battery test facility
Reverse Phase sequence operation
Auto retransfer facility
DSP and Dual microprocessor based system
The Liebert Super 400D is a true
On-line sine wave UPS system that
provides the user with clean
computer grade power for
continuous operation of his critical
load, regardless of any disturbance
on the upstream AC power. The
system offers many innovative
features to give the user maximum
reliability and flexibility at the lowest
operating cost. With Liebert Super
400D UPS system, you have
complete peace of mind.
10,20
Unity Input Power Factor
Low Input Current Harmonic Distortion of less than 5%
Super 400D (10/20 kVA)
-
19
Technical Data
Input Parameters
Input VoltageInput Voltage Variation Input Frequency Input Frequency Variation Power walk in Power Factor at rated load Operation with Reverse Phase Sequence
Bypass Supply Voltage
Nominal DC bus voltagePermissible DC voltage variationDC bus OV tripEnd of discharge DC busTypes of batteries supportedNominal battery float voltageMax. batt.charging currentDC rippleD.C. Voltage Regulation
Output VoltageFrequencyPower rating at 0.8 p.f.Power rating at 1.0 p.f.Overload Rating
Max. Non-linear load permissibleOutput Voltage regulationTransient response for 100% load changeRecovery timeFreq. stability unsynchronized -synchronized -Max. rate of change of FrequencyOutput Voltage Distortion
Transfer time synchronized -unsynchronized -
Voltage limits for Inv. operationSMF battery Float Charge VoltageMax. Charging current
Height x Depth x WidthWeightVentilationCable entryColour / Panel finishBase castor wheels
Operating TemperatureStorage TemperatureRelative HumidityAltitudeTemperature DeratingAltitude Derating
415V, 3-Phase, 4 wire- 30%, +25 % 50 Hz +/- 10% Progressive over 10 seconds 1.0 (Unity) Possible
220/ 230/ 240V AC
356V 260V - 410V 410V 260V SMF 356V 7.0A< 2% rms ± 1%
220/ 230/ 240 VAC 1 Phase 50 Hz 10 kVA, 20 kVA 8 kW, 16 kW 110 % for 60 minutes 125 % for 10 minutes 150 % for 1 minute100 % with Crest Factor of 3:1 +/- 1% +/- 10% 10 millisecond +/- 0.1 % ± 1Hz, ± 2 Hz, ± 3 Hz 0.2 \0.4 hz/sec < 3 % at Non linear load < 2 % at linear load0 millisecond 20 millisecond
260V DC to 410V DC 26 Blocks of 12 V each 356 VDC 7.0 A
1150mm x 650mm x 450mm 275kg Forced - Air cooled Front end - Bottom Structured dark Grey Yes
o o0 C to 45 C, continuous
o o0 C to 70 C 95% RH 1000 Meters
o o1.5% per C between 40 & 50 C 1 % per 100m between 1000m - 2000m
Bypass Parameters
DC Parameters
Output Parameters
Parameters
Mechanical Parameters
Environmental Parameters
-
20
Applications
Features
Series 7400 M (10/30/40/60 kVA)Maximum Protection For Mission Critical Network Applications
The Liebert Series 7400 M
addresses all the power
quality needs of today’s
networked economy by
providing a perfect sinewave
output voltage with stable
frequency, over and above
offering many other
important customer values.
Series 7400 M (10/30/40/60 kVA)in Rack and Tower Mode
•Information TechnologyServers (LAN, WAN, e-mail, ERP, Web, Digital Archives, IntraNet)
Networking (Routers, Hubs, Switches, Multiplexer, Bundler,
Unbundler, Modems)
Banks, Insurance and Financial Services
Telecommunications, Billing Computers
Medical Diagnostics, MRI, CT Scan, Cath Lab
Process Automation, Small processes, Light Robotics
••••
•On-line double conversion UPS: makes your load independent from both main's voltage and frequency.
Ensures Server-grade high quality of power
IGBT technology PWM inverter switching technology:
provides your load with perfect sinewave voltage
High efficiency performances: lower cost of ownership
Excellent performance with either 100% unbalanced and
100% non-linear loads with crest factor upto 3:1 without
derating: no need to care about the distribution of your
single phase loads between output phases nor to oversize
the UPS
Super-servers, mini-computers and multi-processing systems
Advanced battery management systems with programmable
battery testing: constantly monitors the the health of the
battery pack keeping the battery ready to work for emergency
situations
Small footprint and convenient maintenance access: ease
of positioning and saving of floor-space
Inverter with high overload capability: no need to oversize
UPS; reduced initial investment
Inverter output protected against short-circuit: high
protection to the inverter hence more availability of the
systems; Investment protection
Zero footprint for optional tuned filter for the input: lower
cost of ownership because of space saving and reduced
electricity bill
•
••
••
•
•
•
•
-
21
Technical Data
Model 10 30 40 60
Power 10kVA 30kVA 40kVA 60kVA
Output Power 8kW 24kW 32kW 48kW
Power factor 0.8
Input
Voltage 380/400/415 V
Frequency 50 or 60 Hz
Power Factor > 0.9 (Additional Filter)
THDi < 10%-15% with Battery charging
Voltage Window + 10%-20% without battery charging
Output
Voltage 380/400/415V
Frequency 50 or 60 Hz
Voltage stability
- static +_ 1%
- dynamic +_ 5%
Voltage distortion
- linear load 1% typical
- non-linear load 5% max (with 3:1 crest factor)
Overload capability three-phase: 110% for 60 mins,
125% for 10 Mins, 50% for 1 min
Single-phase: 200% for 30 secs
Maximum permissible non-linear load 100% (with 3:1 crest factor)
Physical
Weight 480kg 540kg 620kg
Width 710mm 710mm 710mm
Height 1420mm 1420mm 1420mm
Depth 800mm 800mm 800mm
20 kVA model also available on request.o oOperating Temperature is 40 C. However ratings can be selected for ambient temperature upto 50 C
-
22
True On-Line Sinewave UPS System ForThe Networked Economy
Applications• Telecommunications Facilities• Data processing• Medical imaging equipment• Industrial process equipment
• Functional & Research Laboratories
The Liebert iTrust 3-phase is a true on-line 3 phase UPS system (sine wave output) that provides the user with clean computer grade power for continuous operation of his critical load, regardless of any disturbance on the upstream AC power. The system offers many innovative features to give the user maximum reliability and flexibility at thelowest operating cost. With Liebert iTrust 3-phase UPS system, you have complete peace of mind.
Liebert iTrust 3-Phase UPS System
• Parallel for Redundancy or Capacity for up to 4 units• Full Digital Signal Processing using the latest DSP technology• Wide Input Voltage Range• Low Current Harmonic Distortion of less than 3%• High Input Power Factor• High Overload and Short-Circuit Capacities• Intelligent Battery Management• Large LCD Display and Mimic Panel for Real-time information
Features
• Large Format Departmental Stores & Multiplexes
• MTBf over 5,00,000 hrs ensuring reliable power supply• Power supply efficiency over 97% through Bypass during good• mains supply thus minimizing operating cost
iTrust 3-Phase UPS
-
23
Technical Data
Capacity 30kVA 40kVA 60kVARectifier InputInput Voltage 380/400/415v [line-to-line voltage]AC power input three-phase three-wirePower factor >0.99Harmonic current
-
24
Liebert NXNext GenerationUninterruptible PowerSystems
Applications•Server Rooms and Mid-sized Data Centers
•Telecommunication (Fixed, WiLL & Mobile) Billing & Reporting
Systems
•Networks (LAN, MAN & WAN), InfoCom and WiFi Hot Spots
•Industrial Process & Motion Automation for Mid-sized plants
•Medical Diagnostic / Imaging Equipment
Features•Stratified cooling techniques•Versatile and simultaneous communication facilities•Compact active and passive footprints•Capability to handle 0.9 leading power factor loads•Capability to handle 100% unbalanced loading•Backfeed protection•User f lexibility in selecting effective conÞ guration for the application•Large and user-friendly LCD display in twelve different languages•Compatibility to VRLA (SMF), LATB, Nickel Cadmium batteries•Black start facility
Benefits• Hi-Availability of Quality Power• Reduced Cost of Ownership• Upstream Green Power• Ease & Simplicity in Scalability & Redundancy• Investment Protection
Liebert NX – the next generation,true on-line, double conversion digital UPS – is designed to appropriately address the“Hi-Availability Quality Power”need of B2B and B2C businesses.Innovation, simplicity and low costof ownership have been delicatelyconverged in Liebert NX to offeryou the highest capital investment return. With the Liebert NX, you can rest assured that you havehigh nines quality power for yourcritical business applications.
Liebert NX comes in six popular ratings: 30, 40, 60, 80, 100 & 120 kVA.
Liebert NX
-
25
Technical Data
Rated Power @ 0.8 PF [kVA] 10 15 20 30 40 60 80 100 120 140 160 200
Rectifier Type IGBT-based Vector Controlled PFC (PF Corrected)
Input Voltage [Vac] 380 / 400 / 415 (Accepted from 305 to 477 without batt. Use)
Input Frequency [Hz] 50 or 60 (Accepted range from 40 to 70)
Input Current THD
-
26
Applications• Facility-wide networks• Medical equipment• Industrial processes-Automation• Transport Automation
Features
From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them allefficiently and effectively.
Hipulse is carefully designed to maximize the availability of your critical loads to ensure that your business is protected to the maximum extent possible against power quality problems as well as complete power failure.
• On-Line Double Conversion• IGBT-based PWM Inverter• Wide input voltage tolerance (+10/-15%)• Wide input frequency tolerance ( 5%)• Automatic battery testing• Common battery sharing kit (optional) with 1+1 configuration• Built-in maintenance bypass (Single and 1+N Models)• Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA• UPS modules in Dual Bus configuration using optional HiSync on
the Upstream (with UPS), HiSwitch in the downstream (after UPS) and load-end SmartSwitches
• Provision to use any type of battery: Wet cells (Tubular or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance free and Nickel Cadmium
• Field settability of end-cell voltage of the battery• Intelligent web communications and automatic graceful computer
shutdown operations
Liebert Hipulse UPS (30-150 kVA 1-Phase)in Rack and Tower Mode
• N form software for full-scale and cost-effective monitoring• Site scan web solution tool for online monitoring
• Large Computer Rooms
Liebert Hipulse UPSDigital UPS For The Digital World & Industrial Automation
-
27
Technical Data
Nominal rating [KVA](0.8 pf) 25 40 60 80 105 130 150
Depth[mm]
Width[mm]
Height[mm] 2110 2110 2110 2110 2110 2110 2110
Voltage 380/400/415V(+10/-15%)-3ph-3W
frequency 50 or 60 Hz +/- 5%
Power factor 0.8-0.92
Voltage stability 230/1 ph
Voltage stability -steady state (+/-)1.5%
100% load Step (+/-) 5%
Frequency Stability- Synchronized with the bypass supply (+/-)1%
- Auto -synchronized (+/-) 0.1%
Overload capacity from inverter at
nominal voltage 110% for 60 minutes,125% for 10 Minutes,135-150% For 1Minute
Short circuit current from inverter 1.5 in for 5 seconds(in accordance with EN50091-1-1)
Voltage distortion with linear load 2% max
Voltage distortion with 100% Non
linear load
-
28
Applications• Facility-wide networks• Medical equipment• Industrial processes
Features
From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them allefficiently and effectively.
Hipulse is carefully designed to maximize the availability of your critical loads to ensure that your business is protected to the maximum extent possible against power quality problems as well as complete power failure.
Liebert Hipulse UPS(80-800 kVA 3-Phase)
Liebert Hipulse UPS (80-800 kVA 3-Phase)in Rack and Tower Mode
• On-Line Double Conversion• IGBT-based PWM Inverter• Wide input voltage tolerance (+10/-15%)• Wide input frequency tolerance ( 5%)• Automatic battery testing• Common battery sharing kit (optional) with 1+1 configuration• Built-in maintenance bypass (Single and 1+N Models)• Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA• UPS modules in Dual Bus configuration using optional HiSync on
the Upstream (with UPS), HiSwitch in the downstream (after UPS) and load-end SmartSwitches
• Provision to use any type of battery: Wet cells (Tubular or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance free and Nickel Cadmium
• Field settability of end-cell voltage of the battery• Intelligent web communications and automatic graceful computer
shutdown operations
Digital UPS For The High-EndDigital World
• Telecommunication• Data Centers in IT/ ITES/ BPOs• Server & Networking• Entertainment & Media• Server Farms
• N form software for full-scale and cost-effective monitoring• Site scan web solution tool for online monitoring
-
29
Technical Data
Hipulse UPS System
Nominal Rating [kVA] (0.8pf) 80 120 160 200 300 400 500 600 800
Rectifier Type 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p 12p 12p 12p
Physical Characteristics
Depth [mm] 875 1000
Width [mm] 900 1300 1250 1890 1250 1890 1250 1890 1640 2280 2460 2460 3200 3200 4400
Height [mm] 1900
Weight [kg] 750 1120 1000 1475 1200 1725 1350 2000 1850 2540 2400 3100 4200 4500 5050
Input
Voltage 380/400/415V (+10/-15%) 3Ph 4w
Frequency 50 or 60 Hz +/-5%
ITHD 4-10% with optional input filter
Power Factor 0.90- 0.94 with optional input filter
Output
Voltage Stability 380/400/415V 3Ph 4w
Voltage Stability
-Steady State +_ 1%
100% Load Step +_ 5%
Frequency 50 or 60 Hz
Frequency Stability
-Synchronised with the bypass supply +_1%
- Auto Synchronised +_0.1%
Overload capacity from inverter at nominal voltage
-3ph 10% for 60 minutes, 125% for 10 minutes, 135-150% for 1 minute
-1ph 200% for 30 seconds
Short circuit current from inverter
-3ph 1.5 In for 5 seconds 9in accordance with EN 50091-1-1
- 1 ph 2.9 In for 5 seconds 2.2 In for 5 seconds
Voltage Distortion With Linear Load
-
30
Applications
Features
Liebert Precision Power Center
Liebert Precision Power Center
Liebert delivers the packaged power solution through precision power center (PCC), creating high quality power to protect the operation of a critical facility. It is a all in one power system at an affordable price that will close the power delivery loop in your critical facility.
Affordable and reliable operation of PCC ensures that power is distributed properly to each piece of your important equipment and you get maximum safety standards.
• Computer rooms• LANS/WANS • Communications facilities• Office areas• Medical imaging suits• Grouped workstations• Process control rooms• High-tech manufacturing power sites.
• Computer-Grade grounding • Handles non linear loads• Online communication tools • Compact single cabinet• Single input cable connections• Easy relocation• Expansion capabilities for future requirement• Onsite power monitoring• Secure distribution and circuit identification• Central monitoring interface• Space saving and easy to install• Optional system enhancement system• Circuit identification.
Affordable Packaged Power Management For Higher Power Quality
-
31
Technical Data
Precision Power Center
Output
KVA 50 75 100 125 150 200 225
Input
Voltage 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380 415 400 380
Input Circuit
Breaker (Amps) 100 100 100 150 150 150 200 200 200 250 250 250 300 300 300 400 400 400 400 400 400
Panel Board Poles
Std 24 24 48 48 72 96 96
Opt** 96 96 96 96 96 96 96
Dimensions (cm)
W 600 600 600 600 800 800 800
D 1000 1000 1000 1000 1200 1200 1200
H 2000 2000 2000 2000 2000 2000 2000
Weight
Kg 420 520 630 710 860 1045 1110
Dimensions (cm)
Output 2.0 2.55 3.3 4.06 4.5 6.0 6.75
• KVA : 50-225, 3 phase
• Input : 3 Phase 3-wire plus ground 380, 400 or 415 volts : 50 Hz (Transformer less system require 3 phase, 4w & G)
• Output : 3-phase, 4-wire plus ground220/380,230/400 or 240/415 volts: 50 Hz
• Alarm conditions : O/P & under voltages; O/P overload;neutral and ground over currents; o/p voltage THD;
Transformers over temperature; frequency deviation;phase sequence error; phase loss; 5 customer specifiedalarm conditioning
• •
•
• •• •
•
•
•
•
•
Ground : Single point reference on separately derived system
Distribution : Individually protected 125 Amps panel board with bolt on breaker and flexible output cables
Cooling system : convection / forced
Monitored parameters : I/P & O/P Voltages; o/p, Neutral & grounded currents / P voltage THD; K& crest factor; KVA;KW; PF; % load; KW Hrs; frequency; o/p current THD
Efficiency : 96-98%
Voltage Adjustment : 10% to + 5% of nominal in 2 ½ %increments
•
• •
•
•
-
32
Liebert Powersure PanelTransient Voltage SurgeSuppressor
Applications
•Telecommunications and broadcasting Voice and data networks as well as television and radio
broadcasters rely on high quality power for f lawlesstransmission.
•Industrial electronics Factories require noise free voltage to keep process control
machines running at maximum productivity with minimum downtime.
•Computer equipment and networks Office, shops, superstores and other retail businesses need clean power to maintain the integrity of computers and data.•Telecommunications switchgear and cellular facilities
Reliable power is essential to ensure networks work reliably, 24 hours a day.
•Hospitals Closely controlled power is essential in critical areas such as
operating theatres and intensive care.
Liebert Powersure Panel utilizesPatent pending circuitry to monitorthe status of all protection modes,Including neutral to ground. Should protection be unavailable in any mode, the green LED will be out,and the red LED will illuminate andan audible alarm will sound. In addition, high isolation form C drycontacts for remote monitoringprovide indication of: suppressionsystem failure, under voltage, andphase or power loss. LiebertPowersure’s patent pending Suppression Integrity monitoringIndicates failure for both shorted oropened suppression components.
For Unparalleled Protection That Exceeds Industry Standards...
The Liebert Powersure Panel incorporates proven technology toprovide unparalleled protection from transient surges and electricalline noise (ELN).
Liebert Powersure Panel
-
33
Features
• Compact module attaches directly to breaker panel• CE marked, complies with EMC and low voltage directives• Patent Pending Powersure Detection Circuitry• Easy, safe, maintenance free operation• Repeatable surge current capability• Can be retrofitted to existing panel boards• High isolation dry contacts for remote monitoring• Designed for maximum safety• 5 Year warranty
The Powersure Series At a Glance
• Connection means: Parallel connectedAgency listings: UL1449, Ul1283, CSA, CE,
BS6651 • Protection modes: All modes standard (L-N, L-G,
N-G, L-L); optional-any combinationEMI/RFI Attenuation: 60dB typical
• Response time: Less than .5ns• Operating Frequency: 47/63 Hz• Enclosure: Gray Noryl HS-1000, Rated 94-5V,
Nema, 12, 4, 4X, IP65, IP66Fault Current Rating: 300,000 AIC
• Line frequency: 47-63 Hertz• Temperature: -40 to +60 degrees C
Relative humidity: 0 to 95% noncondensingAltitude: 0 to 5500m
• Audible noise: Less than 45 dBa
Technical Data
Lower Exposure Medium Exposure
Connection Type Parallel Parallel
Operating Voltage Range -15% -15%
Surge Current Capacity 25kA, 50kA or 100kA 100kA or 160kA
Fault Current Rating ( A/C ) 14kA/C 65kA/C
Dimensions 4.72”x4.72”x2.36” (160 kA units) 8”x6”x4”
(100 kA units) 6”x4”x3”
Operating Frequency Range 47…63 Hz 47…63 Hz
Capacity Continuous Continuous
EMI/RFI Attenuation 40 dB typical 40 dB typical
Response Time
-
34
ASCO SwitchDesigned To MinimizeDowntime On CriticalSystems
Applications•Healthcare Facilities•Commercial Buildings / Industrial Buildings•Web Hosting, Internet Data Centers•Telecom Central Offices•Process Manufacturing / Wafer Fabrication Plants / Distributed Power / Load Management
ASCO Switches are the standard of the industry. High speed transfer of loads between alternate sources of power, regardless of ampacitysize, is achieved by a reliable, Field proven solenoidoperating mechanism. When combined with a programmable microprocessor controller with keypad and LCD display, they offer the most advanced method of transferring all types of loads, such as motors, electronic drives, UPSs and microprocessor based systems.
7000 Series Power Transfer Switches are available open or enclosed, in ampacity sizes from 30 through 4000 amperes with the largest selection of optional accessories offered anywhere. All switching Configurations are available with an integrally mounted bypass- isolation switch and/ or rated for use in service entrance applications .
ASCO 7000 Series
-
35
Applications•Healthcare Facilities•Commercial Buildings / Industrial Buildings•Web Hosting, Internet Data Centers•Telecom Central Offices
Features•The Series 300 is listed to UL 1008 standard for Transfer Switch Equipment and CSA standard C22.2 for
automatic transfer switches.•Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code (NEC) Articles
700, 701 and 702.•30 through 3000 amps in a compact design, Available to 600 VAC, single or three phase. of loads, such as motors,•Rated up to 600 VAC, 30 through 4000 amperes.•True double- throw operation: The single solenoid design is inherently locked and prevents contacts from stopping between sources or from being in contact with both sources at the same time.•High withstand and close- on ratings•There’s no danger of the Series 300 ATS transferring loads to a dead source because the unique ASCO single- solenoid operator derives power to operate from the source to which the load is being transferred.•Solid, switched, or overlapping neutral conductor options.•Easy- to- read flush- mounted control and display panel provides LED indicators for switch position and
source availability.•It also includes test and time- delay bypass switches as standard features.•Standard engine exerciser for weekly automatic testing of engine generator set with or without load.•Adjustable time- delay feature•Supplied with solid neutral termination.•Standard ground conductor connections.•Optional switched neutral pole available.•Accessory kits available.•Meets IEC 60947-6-1
The ASCO Series 300 was designed for one purpose— to automatically transfer critical loads in the event of a power outage. The rugged construction and proven performance of the ASCO Series 300 assure the user of many years of complete reliability. The Series 300 is even designed to handle the extraordinary demands placed on the switch when starting or restarting stalled motors and switching high inrush loads.
ASCO Series 300
-
36
Emerson NetworkPower Is the OneCompany That CanProvide A CompleteRange Of PowerProtection SolutionsDesigned For AnyFacility And Any Need
Poor power can affect every aspect of your criticaloperations. Critical equipment and processesthroughout your operations can be affected by poorpower quality, outages and other related problems.
Without Proper Power, Vital Processes JustCannot Function
Important computing, communications and industrialprocess control functions all depend on clean, continuouspower to maintain these operations. From a single desktopPC to a large data center, power quality is the commondenominator that must be maintained.
Differing Needs Require Different Solutions
Different parts of your operation have different needs forpower. Depending on the nature of the operation, powerneeds can range from simple surge protection all the wayup to redundant UPS systems and power feeds with back-up generating capabilities.
Threats To Your System’s Availability AreAround Every Corner
There are a number of points within a critical facility wherepower troubles can develop. Adding to this dilemma is thatoperations in one part of your facility can adversely affectthe power in another area of the building. Yourproductivity depends on critical electronic systems – canyou depend on your power to keep them operatingproperly?
-
37
Remote FacilitiesEmerson Network Power’s High-reliability Liebert UPSsystems and DC power equipment are critical tomaintaining operations in telecommunications sheltersand other unmanned structures.
Telecommunications RoomsEmerson Network Power can provide a reliable flow of bothAC and DC power for telephone switching systems andother communications equipment.
Equipment Rack EnclosuresThese densely-packed equipment bays, housing servers orother essential communications devices require UPS back-upplus distribution to get uninterrupted, conditioned power toeach and every component in the rack.
Computer RoomsEmerson Network Power offers the full range of UPS,distribution systems and other power protection equipmentto meet the needs of the largest data centers and networkingfacilities.
Office LocationsWith many mission-critical computing systems locatedright in the office space, there is a need for UPS protectionthat can be placed nearby. Liebert offers a number of powersystems that are especially designed for use in business andoffice environments.
Process Control RoomsEmerson Network Power’s Liebert UPS, surge protectionand power distribution are all key to maintaining theproper operation of process control and othermanufacturing systems that utilize microprocessor andcomputer control.
A Power ProtectionSolution ForEvery Need
-
38
Our End to End Solutions
-
39
Power Is Just Part of The Reliability Story
Liebert Also Offers A Full Range Of Heat Removal Solutions
In addition to proper power, sensitive electronic computer and communications systems also require the correct environment in order to function reliably. Because this equipment produces heat, it is absolutely necessary to control and maintain the temperature and humidity levels where it is located in order to assure continuous operation.
The Widest Range Of Products Gives You An Infinite Range Of SolutionsAs network equipment gets smaller and packed tighter, it creates unprecedented heat densities that can result in thermal shutdown or total component failure. Precision air conditioning, specialized enclosures and rugged remote protection can assure network uptime against this threat.
From high-capacity units to compact above-ceiling systems there is a Liebert system designed to cool and protect your critical computing systems. We make the industry’s widest range of precision environmental control, including air conditioners, fluid chillers and heat rejection systems in capacities from one to more than 65 tons. These systems are available with a choice of cooling methods, including chilled water, air cooled and glycol cooled models, as well as ultra energy efficient GLYCOOL™ and Dual-Cool configurations.
We also offer specialized systems, including exterior mounted air-conditioning for telecommunications enclosures, supplemental cooling for high-density electronic applications.
End to EndSystem SolutionsWith EmersonNetwork Power
-
24
Emerson NetworkPowerGlobal Services
FACTORY TRAINEDYou can be sure that the only people who deal with your Critical Air Equipment will be 100% Factory Trained Emerson Service Experts
ORIGINAL PARTSYou can be sure that the parts you will receive from our 100% Emerson Service Experts are 100% Original Parts. With our multi-tiered parts availability program, you are ensured that parts will be made available to you when and where you need them.
VERSION CONTROLYou are assured of 100% Version Control so that your critical business systems won’t have to experience downtime due to incompatibility.
SUPPORT NETWORKWe not only help you develop you Environmental Control System, but our 100% Emerson Service Experts also offer a Full Support Network so that your critical systems have a 100% Safety Net every step of the way.
QUALITY RESPONSEWe know it is important to get to your critical systems on time. With our 100% Emerson Service Experts you don’t just get prompt service; you also get 100% Quality Response. This means no useless tinkering, no wasted time-- just Quality Service, straight away.
100% Emerson Service Experts.Would you settle for anything less?
-
41
Our Capability Literally Extends From “Grid to Chip”, Offering The Broadest Range of Solutions To The Market.
Emerson Network Power offers:
• DC Power Systems (Small, Medium, and Large Systems)
• Uninterruptible Power Systems (from 500VA to 1000 kVA)
• Precision Air Conditioning for Computer Rooms
• Automatic Transfer Switches Medium and Low Voltage
• Static Switches
• Shelter Air Conditioning for Telecommunications
• Specialized Enclosures to protect Critical Network Equipment
• Surge Suppression and Filtering
• Site Monitoring Equipment
• All Operating System associated Software
• Emerson Network Power Global Services (24X7X365 support for all our customers)
Our PortfolioShapes OurSolutions
-
Emerson Network Power.
While every precaution has been taken to ensure accuracy and completeness in this brochure, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2008 Emerson Electric Co.
TMThe global leader in enabling Business-Critical Continuity .
Voice of Customers UPS Awards 2006-07 for Product Line& Customer Service Awards in IT, Telecom,
Large Enterprise & Hospitals andCustomer Service Leadership Award in BFSI
Best IT Hardware CompanyMaharashtra IT Award 2006-07
2007R
Emerson Network Power1050, Dearborn Drive, P. O. Box: 29186Columbus, Ohio - 43229Tel.: 800.877.9222 (US & Canada Only)Tel.: 614.888.0246 (Outside US)Fax: 614.841.6022
Country OfficeEmerson Network Power (India) Private Ltd.Plot No. C-20, Road No. 19, Wagle Estate,Thane (w), Maharashtra - 400 604. India.Tel.: 91-22-67208000Fax: 91-22-25828358
City Offices
East ZoneKolkata : 033-40023100Jamshedpur : 0657-2227678Guwahati : 0361-2734486Bhubaneshwar : 0674-2586003/3299872
South ZoneBangalore : 080-41135670/770/870Secunderabad : 040- 27806771/772Cochin : 0484-2341985/86Chennai : 044-28151063/28152596Vishakapatnam : 0891-2505540/41/42Coimbatore : 0422-4387625
West ZoneGhatkopar : 022-67208800/67209000Pune : 020-66235000Baroda : 0265-2314296/2330383Nagpur : 0712-5634997Indore : 0731-4023806Ahmedabad : 079-27560230/40Vikhroli : 022-40780303
North ZoneNew Delhi : Chandigarh : 0172-5077531Lucknow : 0522-2237174
011-28753214/0774/2218
Gurgaon : 012-4470015/16/17Jaipur : 0141-4024774
Outside Plant
Power Switching & Controls
Precision Cooling
www.emersonnetworkpower.co.in
Racks & Integrated Cabinets
Services
Surge Protection
Embedded Computing
Embedded Power
Monitoring
AC Power
Connectivity
DC Power
Page 1Page 2Page 3Page 4Page 5Page 6Page 7Page 8Page 9Page 10Page 11Page 12Page 13Page 14Page 15Page 16Page 17Page 18Page 19Page 20Page 21Page 22Page 23Page 24Page 25Page 26Page 27Page 28Page 29Page 30Page 31Page 32Page 33Page 34Page 35Page 36Page 37Page 38Page 39Page 40Page 41Page 42Page 43Page 44