take the stress out of fluid management - pan...

12

Upload: others

Post on 26-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely
Page 2: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

Sensitive In-Line Pressure SensingThe unique in-line pressure-sensing system provides instantaneous adjustments to flow levels based on intraarticular pressure changes, providing ideal joint distention throughout the procedure. Pressure and flow levels can be adjusted independently on the pump or from the sterile field with the autoclavable remote for optimum control of fluid dynamics. Clear joint distention is maintained even with aggressive shaving, aspiration and multiple arthroscopy portals.

Set-Up and User SimplicityEasy main tubing set-up, sensor plug-in and multipleirrigation bag spiking before the first patient is in the room facilitates stress-free preparation for the entire surgical day. The unique ReDeuce™ tubing extension piece is passed off from the surgical field and connected to the main pump tubing for each subsequent arthroscopic procedure. Touch- proof connectors, backflow restrictors and sterile caps provide full assurance of tubing and fluid sterility during tubing connection.

Tubing and Fluid Cost ContainmentTubing cost and unused fluid waste are significantly reduced because only the extension tubing piece is disposed of at the end of procedure. The main pump tubing and unused sterile fluid bags, which are in a closed sterile loop, remain maintained on the pump for the surgical day.

Reliability and SafetyUnique digital sensing in the Continuous Wave™ III Arthroscopy Pump displays misuse or malfunction for complete patient safely. It incorporates the latest features and benefits to meet the highest demands of surgeons, surgical nurses and administrators in today’s performance, safety and cost containment hospital and ASC environment.

Take the Stress Out of Fluid Management in Arthroscopy

Take the Stress Out of Fluid Management in Arthroscopy

Page 3: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

Advantages of the Continuous Wave III Arthroscopy Pump include a new and improved advanced fluid drive system that maintains distention even during aggressive shaver suction and ACL procedures. Fluid turbulence has been virtually eliminated with a new smooth transition from start to stop, maintaining a stable fluid environment with safe intraarticular pressure. A flush control now allows the pump to provide hemostasis at the touch of a button. An improved noise dampening system allows the pump to operate quietly.

All of these features come together to provide surgeons and the OR staff with a truly unique and stress-free fluid management system.

The new Continuous Wave III Arthroscopy Pump Stand features a storage basket, a hanger for up to four fluid bags, stable base, rugged construction and a new modern appearance.

AR-6477 Arthroscopy Pump Stand with Telescoping Bag Hanger (holds up to four fluid bags)

The Continuous Wave III Arthroscopy Pump has an optional autoclavable remote that has pressure, flow and on/off functions. The remote also features a flush option that increases pressure by 50% while increasing the flow to 100% while activated.

AR-6476 Remote Control for Continuous Wave III Arthroscopy Pump, autoclavable

Pump Stand

AutoclavableRemote Control

The Arthrex Continuous Wave III Arthroscopy Pump

AR-6475Continuous Wave IIIArthroscopy Pump

Continuous Wave IIIArthroscopy Pump

Page 4: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

AR-6410 Main Pump Tubing

AR-6220 Extension Tubing

AR-6215 Y-Tubing Adapter

Main Pump Tubing This tubing set is for those who prefer a complete tubing set and want to replace the fluid bags after each case. Each tube set comes with an independently packaged press-fit luer lock to allow for tubing length adjustment if used in conjunction with the Extension Tubing. If used alone, the set must be discarded after each use.

AR-6410 Main Pump Tubing for AR-6400 or AR-6475, 16’ long, sterile, qty. 10

Extension TubingThis unique tubing provides an economical option to reduce tubing costs by allowing the Main Pump Tubing to remain in use for the entire surgical day. The exclusive backflow valve prevents contaminated fluid from reaching the Main Pump Tubing. The Main Pump Tubing and fluid bags no longer need to be discarded after each surgical case.

AR-6220 Extension Tubing, 8’ long, sterile, qty. 20

Y-Tubing AdapterThe optional Y-Tubing Adapter allows four fluid bags to be attached to either the Main Pump Tubing or the ReDeuce Pump Tubing, resulting in fewer fluid bag changes.

AR-6215 Y-Tubing Adapter, double spike, 2 per set, sterile, qty. 10

Pump Tubing Options

Page 5: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

AR-6410 Main Pump Tubing

AR-6215 Y-Tubing Adapter

ReDeuce Pump TubingReDeuce Tubing is a cost-effective two-part tubing system that allows the pump tubing to stay in place through the surgical day. Only the patient tubing is replaced after each case.

AR-6411 ReDeuce Pump Tubing w/connector for AR-6400 or AR-6475, 8’ long, sterile, qty. 10

• The ReDeuce system saves fluid by not requiring the remaining fluid to be discarded after the termination of a surgical case.

• The ReDeuce system saves tubing costs, as the main tubing stays in place through the surgical day. Only the ReDeuce Patient Tubing needs to be replaced for each case.

• The ReDeuce system saves set-up time. Only the Patient ReDeuce Tubing needs to be passed off from the sterile field before each case. The ReDeuce Pump Tubing stays in place the entire surgical day and no additional fluid bags need to be spiked until they are completely empty.

AR-6411 ReDeuce Pump Tubing

AR-6421 ReDeuce Patient Tubing

A backflow restrictor reduces the risk of contamination by notallowing fluid to flow back through the tube set toward the Pump Tubing Set.

Touch-proof connectors keep contamination from entering the site where the patient and pump tubing connect.

Independent testing facility verified. Touch-proof Connector

ReDeuce™ Pump Tubing System

Backflow Restrictor

ReDeuce Tubing Features and Benefits:

ReDeuce Tubing and Patient Safety:

ReDeuce Patient Tubing The patient tubing is a two meter extension set that extends from the ReDeuce Pump Tubing to the sterile field. Each ReDeuce Patient Tube set contains a backflow restrictor and touch proof connector to maintain sterility from case to case.

AR-6421 ReDeuce Pump Tubing, 8’ long, sterile, qty. 20

Page 6: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

High-flow scope sheaths allow quick response tochanges in pressure and flow. Available in Linvatec/Storz/Arthrex, Stryker and Dyonics camera fittings.

AR-3031Q High-Flow Sheath w/ Stabilizer for 4 mm Arthroscope, one valve, trocar and obturator, quick-lockAR-3016Q High-Flow Sheath w/ Stabilizer for 4 mm Arthroscope, one valve, trocar and obturator, quick-lockAR-3015Q Arthroscopic Sheath for 4 mm Arthroscope, two valves, quick-lockAR-3010Q Arthroscopic Sheath for 4 mm Arthroscope, one valve, quick-lockAR-3036S High-Flow Sheath for Dyonics 4 mm Arthroscope, two valve, trocar and obturator, quick-lockAR-3037S High-Flow Sheath for Stryker 4 mm Arthroscope, two valve, trocar and obturator, quick-lock

Arthroscope Sheaths

AR-3016Q

AR-3031Q

AR-3015Q

AR-3010Q

AR-3036S

AR-3037S

AR-3016QHigh-Flow Sheath

AR-3036SHigh-Flow Sheath

AR-3037S High-Flow Sheath

Page 7: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

The Bridge Cannula System can be used to maintain portals while moving the arthroscope between portals. When used in conjunction with the Inflow Cannula Adapter, it can be connected to any inflow or outflow tubing. The threaded portion can be used to lock into certain shaver blades.

AR-3032-4.5S Bridge Cannula Set, 4.5 mm, includes: (for 4 mm arthroscopes, low-flow) AR-3032-4.5 4.5 mm Inflow/Scope Cannula, 2 ea. AR-3033-4.5 Blunt Obturator for 4.5 mm Inflow/Scope Cannula AR-3034-4.5 Trocar Obturator for 4.5 mm Inflow/Scope Cannula AR-3035 Inflow Cannula Adapter

AR-3032-5.5S Bridge Cannula Set, 5.5 mm, includes: (for 4 mm arthroscopes, high-flow) AR-3032-5.5 5.5 mm Inflow/Scope Cannula, 2 ea. AR-3033-5.5 Blunt Obturator for 5.5 mm Inflow/Scope Cannula AR-3034-5.5 Trocar Obturator for 5.5 mm Inflow/Scope Cannula AR-3035 Inflow Cannula Adapter

AR-3032-6.5S Bridge Cannula Set, 6.5 mm, includes: (for 4 mm arthroscopes, high-flow) AR-3032-6.5 6.5 mm Inflow/Scope Cannula, 2 ea. AR-3033-6.5 Blunt Obturator for 6.5 mm Inflow/Scope Cannula AR-3034-6.5 Trocar Obturator for 6.5 mm Inflow/Scope Cannula AR-3035 Inflow Cannula Adapter

AR-3035L Inflow Cannula Adapter with Stopcock

The Bridge Connector attaches to the bridge cannula and provides a fitting for an Olympus® TrueView Direct or Olympus TrueView arthroscope. With a two cannula set, the camera can be easily moved from portal to portal with minimal repositioning. The Bridge Connector also attaches to AR-3032-5.5S and AR-3032-6.5S.

WS-1603/1 Bridge Connector for Olympus TrueView IIWS-1603/2 Bridge Connector for Olympus TrueView Direct

The 4.5 mm Flexible Inflow Cannula eliminates potential articular cartilage damage and adapts to knee anatomy to retain inflow/outflow. The Irrigation Cannula Set includes a reusable trocar, obturator and stopcock.

AR-6500S Irrigation Cannula Set Includes: AR-6501 Valve for Inflow Set AR-6502 Trocar for Inflow Set AR-6503 Obturator for Inflow Set AR-6525 Flexible Inflow Cannula, 4.5 mm x 7.5 mm, qty. 25

Inflow Options

AR-3032-4.5SBridge Cannula Set

WS-1603/1 Bridge Connector for Olympus TrueView II

AR-6525Flexible Inflow Cannula

WS-1603/2 Bridge Connector for Olympus TrueView Direct

AR-6503 Obturator for Inflow Set

AR-6502 Trocar for Inflow Set

AR-6501 Valve forInflow Set

The Metal Luer Lock Adapter attaches to any standard luer lock fitting. The hose barb fitting on the reverse facilitates easy attachment of non-luer lock type tubing.

AR-6221 Metal Luer Lock Adapter

AR-3035LInflow Cannula Adaptor with Stopcock

Page 8: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

The 5.75 mm Crystal Cannula features a distal retaining ringto prevent cannula “fall-out”.The smooth version permits the smallest possible incision. The small outer diameter and the uniquely designed obturator provide maximum control for insertion into small portals.

The translucent cannula facilitates arthroscopic visualization ofinstruments and sutures through the cannula walls. The cannula is molded from durable polycarbonate to minimize suturefraying and breakage and has been designed to eliminate “squirting”. There is an optional 1-Way Stopcock to control fluid outflow or inflow.

AR-6560 Crystal Cannula, 5.75 mm I.D. x 7 cm w/obturator, qty. 5AR-6562 Crystal Cannula Smooth, 5.75 mm I.D. x 7 cm w/obturator, qty. 5AR-6561 1-Way Stopcock, w/luer lockAR-6563 Reusable Obturator for AR-6560, AR-6562, and AR-6564AR-6564 Crystal Cannula, partially threaded distal end, 5.75 mm x 7 cm, w/obturator, qty. 5AR-6568 Short Crystal Cannula, 5.75 mm I.D. x 5 cm, partially threaded, sterile, qty. 5 (for small joint arthroscopy only)

The Partially Threaded Cannula allows uninhibited visualization of instruments and sutures through the cannula walls, helping surgeons prevent suture entanglement and allowing visualization of arthroscopic knots as they are delivered down the cannula. The cannula has

threads only on the distal section of the cannula, allowing the surgeon to quickly adjust the working length of the cannula.

AR-6566 Partially Threaded Cannula w/No Squirt Cap, 8.25 mm x 7 cm, w/obturator, qty. 5AR-6567 Partially Threaded Cannula w/No Squirt Cap, 7 mm x 7 cm, w/obturator, qty. 5AR-6575-09 Partially Threaded Cannula w/No Squirt Cap, 8.25 mm x 9 cm, qty. 5AR-6575-11 Partially Threaded Cannula w/No Squirt Cap, 8.25 mm x 11 cm, w/obturator, qty. 5

AR-6541 Reusable Obturator for AR-6575-09AR-6576-11 Reusable Obturator for AR-6575-11

Crystal Cannula®

Partially Threaded Cannula

AR-6563 Reusable Obturator

AR-6560 Crystal Cannula

AR-6566 Partially Threaded Cannula

Page 9: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

The Clear Instrument Cannula facilitates arthroscopicvisualization of instrumentsand sutures. The distal flange provides a secure means toprevent migration of the cannula. The flange also allows retraction of the capsule to increase visibility of intraarticular

anatomy. The cannula comes with a plastic, noncannulated obturator or can be used with a reusable, cannulated obturator which has an ergonomic handle to ease insertion over a 4 mm Wissinger Rod or Switching Stick.

AR-6532 Instrument Cannula, 5.5 mm x 9 cm, qty. 5AR-6550 Instrument Cannula, 7 mm x 7 cm, qty. 5AR-6549 Reusable Obturator for AR-6550, purple

The translucent Twist-In Cannula allows direct visualization of instruments and suture passing. Arthroscopic knot tying issimplified since twisted andtangled sutures can be observed and corrected during arthroscopic knot tying. The threaded design greatly inhibits cannula “fall-out”

during instrument removal and allows for capsule retraction for visualization. The side port may be used for irrigation inflow or passive outflow.

AR-6530-N Notched Twist-In Cannula, 8.25 mm I.D. x 7 cm, qty. 5AR-6530 Twist-In Cannula, 8.25 mm I.D. x 7 cm, qty. 5AR-6531 Reusable Obturator for AR-6530 and AR-6530-N, goldAR-6535 Twist-In Cannula, 6 mm I.D. x 7 cm, qty. 5AR-6536 Reusable Obturator for AR-6535, greenAR-6540 Twist-In Cannula, 8.25 mm I.D. x 9 cm, qty. 5AR-6541 Reusable Obturator for AR-6540, blueAR-6545 Twist-In Cannula, 6 mm I.D. x 9 cm, qty. 5AR-6546 Reusable Obturator for AR-6545, redAR-6570 Twist-In Cannula w/ No Squirt Cap, 7 mm I.D. x 7 cm, qty. 5AR-6549 Reusable Obturator for AR-6570 and AR-6550, purple

Clear Instrument Cannula

Twist-In Cannula

AR-6563 Reusable Obturator

AR-6549Reusable Obturator

AR-6545 Twist-In CannulaAR-6546 Reusable Obturator

AR-6550Instrument Cannula

AR-6530 Twist-In CannulaAR-6531 Reusable Obturator

Page 10: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

Hip Length Arthroscope Sheath • Fits hip length, wide angle 4 mm arthroscope• Quick-lock connector for secure connection and fast telescope exchange • High-flow • Trocar and obturator

AR-3115Q Hip Length Arthroscope Sheath

Small Joint Length Arthroscope Sheath • Fits small joint 2.7 mm arthroscope• Quick-lock connector for secure connection and fast telescope exchange • Two valve• Trocar and obturator

AR-3015Q Small Joint Length Arthroscope Sheath

Olympus TrueView II & TrueView Direct Arthroscope Sheaths• Quick-lock connector for secure connection and fast telescope exchange • Automatic click-connector • Long-term autoclavability

A70950A High-Flow Rotating Sheath, 1 stopcock, rotating, for 4 mm TrueView II ScopeA70951A High-Flow Rotating Sheath, 2 stopcocks, rotating, for 4 mm TrueView II ScopeA70954A Trocar Spike, triangular, for A70950A or A70951AA70955A Trocar Spike, blunt, for A70950A or A70951AA70959A Trocar Cover for Lavage, for A70950A or A70951AA70970A High-Flow Rotating Sheath, 1 stopcock, rotating, for 2.7 mm TrueView II ScopeA70971A High-Flow Rotating Sheath, 2 stopcocks, rotating, for 2.7 mm TrueView II ScopeA70974A Trocar Spike, triangular, for A70970A or A70971AA70975A Trocar Spike, blunt, for A70970A or A70971AWA70050A High-Flow Rotating Sheath, 1 stopcock, for 4 mm TrueView Direct ScopeWA70051A High-Flow Rotating Sheath, 2 stopcocks, for 4 mm TrueView Direct ScopeWA70054A Trocar Spike, triangular, for WA70070A or WA70071AWA70055A Trocar Spike, blunt, for WA70070A or WA70071AWA70070A High-Flow Rotating Sheath, 1 stopcock, for 2.7 mm TrueView Direct ScopeWA70071A High-Flow Rotating Sheath, 2 stopcocks, for 2.7 mm TrueView Direct ScopeWA70074A Trocar Spike, triangular, for WA70070A or WA70071AWA70075A Trocar Spike, blunt, for WA70070A or WA70071A

Specialty SheathsAR-3115Q Hip LengthArthroscope Sheath(300 mm)

AR-3015SQSmall Joint LengthArthroscope Sheath(175 mm)

WA70951ATrueView IIArthroscopic Sheath

WA70051ATrueView DirectArthroscopic Sheath

Page 11: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

ArthroVac™

The ArthroVac floor system includes a reusable floor suctionplate with disposable peel-and-stick felt pads to facilitateremoval of excess irrigation fluids in a quiet manner. TheArthroVac is attached to standard operating room suction.The low profile ArthroVac can be placed in the ideal positionfor optimal performance or moved during surgery using thetelescoping handle. The ArthroVac can also be used to facilitate cleaning in between surgeries.

AR-4004 ArthroVac Floor Suction SystemAR-4004H ArthroVac Telescoping Handle and ConnectorAR-4004P ArthroVac Felt Pads, qty. 10

Suction RegulatorThe Suction Regulator provides suction strength adjustment without reducing the inner suction lumen which can cause suction blockage from resected tissue. Precise control is adjusted by sliding the air intake control collar. The suction regulator is fully autoclavable and can be connected anywhere in thesuction tubing line.

AR-6600 Suction Regulator

Tibial Tunnel CannulaThe disposable cannula with integrated silicone dam preserves arthroscopic distention by providing a fluid barrier during an arthroscopic ACL or PCL reconstruction. The silicone dam is fenestrated to allow passage of instruments. A reusable obturator is available to aid in cannula insertion and removal. Accommo-dates 9-12 mm tunnel diameters. Can be cut with scissors 2 cm longitudinally to accommodate smaller tunnels.

AR-1802D Tibial Tunnel Cannula, sterile, qty. 10AR-1807 Reusable Obturator for AR-1802D

Portal PlugThe Portal Plug is a simple solution to excess fluid loss from multiple arthroscopy portals. The Delrin® Plug is inserted into the portal to prevent excess fluid loss and help retain jointextension. The Portal Plug is fully autoclavable and is easy to insert and remove.

AR-1808 Portal Plug

Tunnel PlugThe Tunnel Plug provides a simple means to plug up bone tunnels created during ACL or PCL reconstruction to retain joint fluid distention and arthroscopic visualization. The tapered plug fits securely into tunnels 8 mm to 12 mm in diameter. Manufactured of autoclavable Delrin.

AR-1258 Tunnel Plug

AccessoriesAR-3115Q Hip LengthArthroscope Sheath(300 mm)

AR-4004HArthroVac Telescoping Handle and Connector

AR-6600Suction Regulator

AR-1807Reusable Obturator

AR-1802D Tibial Tunnel Cannula

AR-1808Portal Plug

AR-3015SQSmall Joint LengthArthroscope Sheath(175 mm)

AR-1258Tunnel Plug

AR-4004P ArthroVac Felt Pads

WA70951ATrueView IIArthroscopic Sheath

WA70051ATrueView DirectArthroscopic Sheath

Page 12: Take the Stress Out of Fluid Management - Pan Vetpanvet.com/.../06/continuous-wave-iii-arthroscopy-pump.pdfArthroscopy Pump displays misuse or malfunction for complete patient safely

U.S. PATENT NO. 5,520,638© Copyright Arthrex Inc., 2006. All rights reserved. LB0604C

For assistance in using the products in this brochure, please call theArthrex Tech Support Hotline

1-888-420-9393Monday-Friday, 9 am to 5 pm EST.

Arthrex, Inc.1370 Creekside Boulevard, Naples, Florida 34108-1945 • USA

Tel: 239-643-5553 • Fax: 239-598-5534 • Website: www.arthrex.com

Arthrex GmbHLiebigstrasse 13, D-85757 Karlsfeld/München • Germany

Tel: +49-8131-59570 • Fax: +49-8131-5957-565

Arthrex Latin América3750 NW 87th Avenue, Suite 620, Miami, Florida 33178 • USA

Tel: 954-447-6815 • Fax: 954-447-6814

Arthrex S.A.S.5 Avenue Pierre et Marie Curie, 59260 Lezennes • France

Tel: +33-3-20-05-72-72 • Fax: +33-3-20-05-72-70

Arthrex CanadaLasswell Medical Co., Ltd., 405 Industrial Drive, Unit 21, Milton, Ontario • Canada L9T 5B1

Tel: 905-876-4604 • Fax: 905-876-1004 • Toll-Free: 1-800-224-0302

Arthrex GesmbH Triesterstrasse 10/1 • 2351 Wiener Neudorf • Austria

Tel: +43-2236-89-33-50-0 • Fax: +43-2236-89-33-50-10

Arthrex BvbAMechelsesteenweg 23, 2540 Hove • BelgiumTel: +32-3-2169199 • Fax: +32-3-2162059

Arthrex Ltd.Unit 16, President Buildings, Savile Street East, Sheffield S4 7UQ • England

Tel: +44-114-2767788 • Fax: +44-114-2767744

Arthrex Hellas - Medical Instruments SA43, Argous Str. - N. Kifissia, 145 64 Athens • Greece

Tel: +30-210-8079980 • Fax: +30-210-8000379

Arthrex Sverige ABTurbinvägen 9, 131 60 Nacka • Sweden

Tel: +46-8-556 744 40 • Fax: +46-8-556 744 41

Arthrex KoreaRosedale Building #1904, 724 Sooseo-dong, Gangnam-gu, Seoul 135-744 • Korea

Tel: +82-2-3413-3033 • Fax: +82-2-3413-3035

Arthrex Mexico, S.A. de C.V.Insurgentes Sur 600 Mezanine, Col. Del Valle Mexico D.F. • Mexico

Tel: +52-55-91722820 • Fax: +52-55-56-87-64-72