tallyayudas rapidas

11
© 2007 Weatherford. All rights reserved. Calibrando Profundidad DAX CLIENT Doble Click en HS Encoder Escoger Sensor Calib Ing David Jaimes.

Upload: ldu-sdntdmdrid-osorio

Post on 25-Dec-2015

1 views

Category:

Documents


0 download

DESCRIPTION

TallyAyudas Rapidas

TRANSCRIPT

Page 1: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Calibrando Profundidad DAX CLIENT

Doble Click en HS Encoder

Escoger Sensor Calib

Ing David Jaimes.

Page 2: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Calibrando Profundidad DAX CLIENT

Ubicar el Top Drive en la parte mas baja posible y c onfigurar los parámetros de acuerdo a la información prestada por el tool pusher y dar click en apply, y después en back

Ing David Jaimes.

Page 3: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Calibrando Profundidad DAX CLIENT

Seleccionar el Initial Wrap (Importante si no no se pueden seleccionar los demás parámetros), proceder a poner valores de Depth, Bit Depth y Hook Po sition

Ing David Jaimes.

Page 4: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Calibrando Canales Analogos

Doble click en el canal a calibrar en este caso Pit 1 , dar doble click en el punto 1 para calibrar el mínimo, y en el punto 2 para el má ximo.

Ing David Jaimes.

Page 5: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Calibrando Canales Analogos

Seleccionar en ACQcounts el voltaje mínimo del senso r 4 mA y asignarle el valor mínimo en este caso 0 Bbls, click en Apply, seguir e l mismo procedimiento para el punto alto de 20 mA

Ing David Jaimes.

Page 6: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Calibrando Slip Status

Se necesitan poner los 2 status el Low y el High, u nidades en KLb (Las mismas unidades con las que este Calibrado el Hook Load), E ntiéndase por valor Low el valor de el Hookload cuando esta en cuñas, y el valo r High el valor de el Hookload cuando se encuentra fuera de cuñas.

Ing David Jaimes.

Page 7: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Comandos Basicos OpenBSD

• Change directory

• cd / Change to root directory

• cd .. Change to parent directory (back one folder)

• cd /ww/config Change to specified directory

• · Listing files

• ls List all files in the current directory

Display running tasks

• ps ax Display all running tasks

• ps ax |grep WW Filter list of tasks to those starting with WW piped through

• grep utility

• ps ax |grep h Filter list of tasks to those starting with h piped through grep

• utility

• ps ax |less List running tasks - only so many per pag e

Stop/end running tasks

• pkill WWwits Stop the WWwits task; and restarts it

• pkill –9 WWdac Stop all running copies of the given t ask permanently

Ing David Jaimes.

Page 8: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Comandos Basicos OpenBSD

BSD editor (nano)

• nano wits Edit the wits file

• nano dac_sw.txt Edit the named txt file

BSD file compression utility (tar - zip utility)

• tar –zcvf al.tgz * Compress (zip) the current directo ry into a single file - al.tgz

• tar –zxvf al.tgz Extract the contents of /al.tgz into current directory.

• tar –ztvf al.tgz List the contents of the file al.tgz

Ing David Jaimes.

Page 9: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Crear Pozo

• Crear Pozo.

• Digitar WWsetup, escogemos Well Management

Seleccionamos create new well entry, y seleccionamos q ue tipo de pozo, utilizamos Mudlogging well y después damos un nombre al pozo en este caso va a s er Training 1.

Ing David Jaimes.

Page 10: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Crear Pozo

• Ahora que ya tenemos creado el pozo vamos a activar lo.

• Digitamos qw (este comando nos permite ver que pozos están en el servidor y en que estado)

• Vemos que hay dos pozos pero training no esta activ o vamos a detener el pozo activo y a activar training 1.

• Digitamos WWsetup, Well Management seleccionamos el pozo activo y damos enter, a continuación por medio de las flechas seleccionamos kill, volvemos a dar enter en el pozo y ahora seleccionamos stop y, salimos de WWsetup, digitamos qw y vemos el estado d el pozo debe salir inactive

Ing David Jaimes.

Page 11: TallyAyudas Rapidas

© 2007 Weatherford. All rights reserved.

Crear Pozo

• Volvemos a WWsetup, well Management y ahora seleccio namos el pozo training 1 y damos enter, buscamos enable well logging enter. Salimos de WWsetup y verificamos con qw el estado del pozo.

• Ahora nuestro pozo esta listo para empezar el regis tro, es importante aclarar que solo debe existir un pozo en estado logging en el servidor.

Ing David Jaimes.