TamilNadu Circle Network Training
Purpose
Procedure to check the health of WAN equipment and WAN Links.
How to Check the Health of WAN Links
3
In CDR Project we use Network Node Manager (NNM) to check
The health and status of Links and Routers
How to open NNM
Open the Internet explorer, type the URL
http://10.196.208.181:7510/topology/home.
Cont..
Enter Login User ID and password and click submit.
The Login User ID and password for Tamilnadu Circle is as follows,
Circle Username Password
Tamilnadu Circle TN_User pass123
Monitoring Alarms
After Logging into the NNM, below screen appears.
Cont..
Click on the Launch View Tab.
Cont..
By double clicking on the launch view Tab corresponding SSA will be displayed as
below.
9
Cont..
By double clicking on the SSA will be displayed as below
MEDIATION & PROVISIONING LINKS
Cont..
In Alarm Browser go to View Set Filter. Here we can filter the alarms of
Tamil Nadu Circle based on Date/Time, Node, Severity etc.
To remove filter Go to View Clear filter.
What to do when Node is indicated as Down
Ping the router to check the current status of links.
If it is pinging wait for NNM screen to get refreshed. After refresh
(refresh time is 15min) the links /router should turn back to normal.
If Router is not pinging Perform the following steps at Exchange end.
a. Conduct the Loop test for E1 Links from Transmission room
b. If Loop test is ok, Do Ping test again.
c. If Ping test fails execute “Trace route “ from your PC and
note IP Add where it is dropping.
d. If IP Add is dropping at 172.26.x.x series Please contact
NIB/MPLS and Parallely inform CDR Datacenter.
12
Mediation & Provisioning Link Checkup
You found all the links are ok but mediation portal still states CDR are not up to date
than
It is possible that though E1 links are ok the connectivity between
the router and PSTN switch is down.
Before we get into checking this part …lets understand how the
PSTN switch is connected to Exchange Router.
13
14
PSTN SWITCHS CONNECTIVITY
TO
CDR EXCHANGE/LE-ROUTER
15
Connect to Second Location
E1 link
Connect to First Location
E1 link
Connecting CES/MTE-AXE MEDIATION
Connecting E10B-PC - MEDIATION
Connecting 5ESS/EWSD/OCB MEDIATION
Connecting All exchanges -PROVISIONING
Free
EXCHANGE ROUTER PORT to PSTN SWITCH connectivity
IOP
ACTIVE
IOP
STANDBY
CES
CISCO
2811
ROUTER
PROVISONING
RS232 25 PIN FEMALE
MEDIATION
RS232 25 PIN MALE
CABLE : HCL TO PROVIDE
CDOT EXCHANGE
RJ45 CONNECTOR CROSS CABLE
2Mbps WAN LINK TOWARDS DATACENTER
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
SERIAL PORT
FOR
PROVISIONING
Fast Ethernet 0/0
Serial 0/1/1
EWSD EXCHANGE
MEDIATION
2Mbps WAN LINK TOWARDS DATACENTER
EWSD
SWITCH
CISCO
2811
ROUTER
X.21 15 PIN FEMALEX.21 15 PIN MALE
PROVISIONINGX.21 15 PIN FEMALEX.21 15 PIN MALE
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
CABLE : HCL TO PROVIDE
LAU
For
Mediation
LAU
For
Provisioning
Serial 0/1/1
Serial 0/0/0
5ESS
SWITCH
CISCO
2811
ROUTER
V.35 34 PIN FEMALEV.35 34 PIN MALE
RS232 25 PIN FEMALE RS232 25 PIN MALE
5ESS EXCHANGE
PROVISIONING
MEDIATION
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
CABLE : HCL TO PROVIDE
2Mbps WAN LINK TOWARDS DATACENTER
UN582B
For
Mediation
UN582B
For
Provisioning
Serial 0/1/1
Serial 0/0/0
OCB
SWITCH
CISCO
2811
ROUTER
RS232 25 PIN FEMALE RS232 25 PIN MALE
CABLE : HCL TO PROVIDE
X.25 25 PIN MALE
PROVISIONING
MEDIATION
OCB EXCHANGE
2Mbps WAN LINK TOWARDS DATACENTER
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
ACV11
ACTUJ
RS 530 25 PIN FEMALE
Serial 0/1/1
Serial 0/0/0
AXE-10 /
IP TAX
SWITCH
CISCO
2811
ROUTER
AXE 10 / IP TAX EXCHANGE
MEDIATION / PROVISIONING
CROSS CABLE :
BSNL TO PROVIDE UPTO 2811 ROUTER
2Mbps WAN LINK TOWARDS DATACENTER
Ethernet PortFor
Mediation
FA 0/0
E1OB
SWITCH
CISCO
2811
ROUTER
RS232 25 PIN FEMALE RS232 25 PIN MALE
E10B EXCHANGE (ECIL SCSI)
PROVISIONING
MTE
MEDIATION
CABLE : HCL TO PROVIDE
ETHERNET CONNECTIVITY
MTU INTERFACE CABLE
OMC
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
2Mbps WAN LINK TOWARDS DATACENTER
16 CCM H/W SERIAL PORT
FOR PROVISIONING
Serial 0/1/1
Fast Ethernet 0/0
E1OB
SWITCH
CISCO
2811
ROUTER
RS232 25 PIN FEMALE RS232 25 PIN MALE
E10B EXCHANGE (ECIL PERTECH/ISI)
PROVISIONING
MTE
MEDIATION
CABLE : HCL TO PROVIDE
ETHERNET CONNECTIVITY
MTU INTERFACE CABLE
OMC
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
2Mbps WAN LINK TOWARDS DATACENTER
16 CCM H/W
SERIAL PORT
FOR PROVISIONING
Fast Ethernet 0/0
Serial 0/1/1
E1OB
SWITCH
CISCO
2811
ROUTER
RS232 25 PIN FEMALE RS232 25 PIN MALE
E10B EXCHANGE (MITRA OMC)
PROVISIONING
MTE
MEDIATION
CABLE : HCL TO PROVIDE
ETHERNET CONNECTIVITY
MTU INTERFACE CABLE
OMC
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
2Mbps WAN LINK TOWARDS DATACENTER
EP54.01
SERIAL PORT
FOR PROVISIONING
Fast Ethernet 0/0
Serial 0/1/1
24
EWSD TCP/IP BASED EXCHANGE
MEDIATION
2Mbps WAN LINK TOWARDS DATACENTEREWSD
SWITCH
CISCO
2811
ROUTER
PROVISIONING
X.21 15 PIN FEMALEX.21 15 PIN MALE
CABLE : BSNL TO PROVIDE UPTO 2811 ROUTER
CABLE : HCL TO PROVIDE
RJ4 5
PORT
LAUFor
Provisioning
Serial 0/1/1
SWITCH
Cat cable with
RJ45 connector
Fa 0/0
What to check in case of CDOT switches
Communication between exchange router to CES ( Ethernet cable)
Communication between CES to IOP 0 & IOP 1.
Admn password.
Exchange router to active IOP
Detailed documentation to perform tests between
(CES - IOP for Mediation) & (Exchange router – IOP for Provisioning)
available with ITPC.
25
26
CES CONNECTIVITY TO IOP AND ROUTER
Check Availability of CDR Files in CES
In Windows Explorer type the URL
ftp://<IP Address of CES>/cdr/blg
Type the Username & password. Request for username & password can be
raised with ITPC .
Cont..
It opens a window which displays all the CDR files available within the
CES.
Check Availability Of CES
First Ping to CES IP by giving the command from your desktop which
access to CDR network.
‘Ping <IP Address of CES>’
If not pinging, then try to Ping to Exchange Router IP.
If not pinging E1 links might be down. recheck in NNM
If pinging then check the interface status of fast ethernet 0/0 in NNM.
30
How to Verify Definations Updation status for clients
In CDR Project we use Symantec Client Security (SCS) to Protect
network from Virus
31
Go to Program files – select Symantec system centre console - SSCC
Cont..
32
Extract Symantec system center and Unlock the southdcav server group
Cont..
33
Give the credentials for the southdcav
Cont..
34
Select your server group and check the definition tab to check client def update status if definition tab not present please select antivirus view in menu bar
Cont..
Check Infected PC.
Daily mailer from data centre list the PC ‘s infected with virus
Following report displays the details of infected PC’s of Erode SSA in
Tamilnadu Circle.