tankpac background info request form
TRANSCRIPT
7/28/2019 Tankpac Background Info Request Form
http://slidepdf.com/reader/full/tankpac-background-info-request-form 1/2
© 2005 Physical Acoustics Ltd. 526_ TankpacBGInfo.Form.doc
Page 1 of 2 ISO 9001:2000 Document Doc. No. 526Issue No. 3 TANKPAC Background Info Form Approved:________ Copy No. Date: 24-10-05
TANKPAC Tank Floor Testing ServiceBACKGROUND INFORMATION REQUEST
CUSTOMER LOCATION
CONTACT E-MAIL:________________________________________
TEL:_______________________________________FAX: ___________________________________________
TANK NO. DIAMETER INSULATION
LI NING BASE TEMP MIXERS
CONTENTS _ ________ Category_____(see p.2) SLUDGE LEVEL
ROOF TYPE (fixed/floating) Internal Floating Roof : Y/N FLOOR TYPE : cone up / cone down / flat
COLUMNS (No. and location) __________________________________________________HEATERS_______ YEARS WITH
YEAR BUILT THI S PRODUCT REPAIRS/dates
_____________________________________________________________________________________________
Group 2 Products (see P.2) :Viscosity_______@ _____ degC Density________Melting Point______________
CATHODIC PROTECTION: NONE/ELECTRICAL/SACRIFICIAL (INSIDE/OUTSIDE)
SPECIAL NOTES AND CONCERNS
ON-SITE REQUI REMENTS see Method Statement for detail:-
-Location for test equipment within 20m of tank (further by prior arrangement).-Power to test equipment 240V or 110V with step-up transformer to 240V in mobile lab,(generator can be provided on request - YES/NO please circle).-Access for sensor placement on tank wall at approximately 1m level.-Holes in insulation where required.- Fluid level is recommended to be as high as possible and not normally below 50%. An
exception to this is if optimum conditions for leak detection are not required when levelsdown to 2 x sensor height may be used to monitor corrosion/condition. If there is a likelihoodof internal product condensation drips, or roof corrosion, the level should be as high aspossible and always >50%.
-Tank isolated in advance of test, see method statement (no product movement, particularly in,and all agitators, heaters, re-circulators, etc off.)-It is important there are no internal noise sources as tank floor tests are run at very highsensitivity.
Physical Acoust ics Ltd tel: +44 (0) 1954 231612Norman Way fax: +44 (0) 1954 231102Over Cambridge CB4 5QE e-mail: [email protected]
7/28/2019 Tankpac Background Info Request Form
http://slidepdf.com/reader/full/tankpac-background-info-request-form 2/2
© 2005 Physical Acoustics Ltd. 526_ TankpacBGInfo.Form.doc
Page 2 of 2 ISO 9001:2000 Document Doc. No. 526Issue No. 3 TANKPAC Background Info Form Approved:________ Copy No. Date: 24-10-05
1 – PRODUCT CATEGORY :
Type of product Category Group
Crude oil B 2
Naptha, Gas-oil (base such as platformates, reformats, alkylates, isomerates,condensates, …)
N 1
Gas-oil (finished products), Specials products (White Spirit, …) E 1
Kerosenes (inc TR0, TR4, TRS, …), Diesel (base) and Domestic fuel-oil andother fuels which are liquid at ambient temperature
D 1
J et oil J 1
Diesel and domestic fuel-oil (finished product) G 1
Heavy fuel-oil, slurries, distillates which are not liquid at ambient temperature,
asphalt, paraffins
F 2
Oil H 2
Aromatic solvent (benzene, toluene, …), MEK, Diester S 1
Slops R 1
Chemical products (acid, base) C 1
Water O 1
Various : MTBE, ETBE, liquid sulphur, Alcohol, … X 1
Physical Acoust ics Ltd tel: +44 (0) 1954 231612Norman Way fax: +44 (0) 1954 231102Over Cambridge CB4 5QE e-mail: [email protected]