 TANKPAC Tank Floor Testing ServiceBACKGROUND INFORMATION REQUEST 

CUSTOMER LOCATION

CONTACT E-MAIL:________________________________________ 

 TEL:_______________________________________FAX: ___________________________________________ 

 TANK NO. DIAMETER INSULATION

LI NING BASE TEMP MIXERS

CONTENTS  _  ________ Category_____(see p.2) SLUDGE LEVEL

ROOF TYPE (fixed/floating) Internal Floating Roof : Y/N FLOOR TYPE : cone up / cone down / flat

COLUMNS (No. and location) __________________________________________________HEATERS_______  YEARS WITH

 YEAR BUILT THI S PRODUCT REPAIRS/dates

 _____________________________________________________________________________________________ 

Group 2 Products (see P.2) :Viscosity_______@ _____ degC Density________Melting Point______________ 

CATHODIC PROTECTION: NONE/ELECTRICAL/SACRIFICIAL (INSIDE/OUTSIDE)

SPECIAL NOTES AND CONCERNS

ON-SITE REQUI REMENTS see Method Statement for detail:-

-Location for test equipment within 20m of tank (further by prior arrangement).-Power to test equipment 240V or 110V with step-up transformer to 240V in mobile lab,(generator can be provided on request - YES/NO please circle).-Access for sensor placement on tank wall at approximately 1m level.-Holes in insulation where required.-  Fluid level is recommended to be as high as possible and not normally below 50%. An

exception to this is if optimum conditions for leak detection are not required when levelsdown to 2 x sensor height may be used to monitor corrosion/condition. If there is a likelihoodof internal product condensation drips, or roof corrosion, the level should be as high aspossible and always >50%.

-Tank isolated in advance of test, see method statement (no product movement, particularly in,and all agitators, heaters, re-circulators, etc off.)-It is important there are no internal noise sources as tank floor tests are run at very highsensitivity. 

Physical Acoust ics Ltd tel: +44 (0) 1954 231612Norman Way fax: +44 (0) 1954 231102Over Cambridge CB4 5QE e-mail: [email protected] 

Page 2: Tankpac Background Info Request Form

7/28/2019 Tankpac Background Info Request Form

http://slidepdf.com/reader/full/tankpac-background-info-request-form 2/2

© 2005 Physical Acoustics Ltd. 526_ TankpacBGInfo.Form.doc

Page 2 of 2 ISO 9001:2000 Document Doc. No. 526Issue No. 3 TANKPAC Background Info Form Approved:________  Copy No. Date: 24-10-05

1 – PRODUCT CATEGORY :

Type of product Category Group

Crude oil B 2

Naptha, Gas-oil (base such as platformates, reformats, alkylates, isomerates,condensates, …)

N 1

Gas-oil (finished products), Specials products (White Spirit, …) E 1

Kerosenes (inc TR0, TR4, TRS, …), Diesel (base) and Domestic fuel-oil andother fuels which are liquid at ambient temperature

D 1

 J et oil J 1

Diesel and domestic fuel-oil (finished product) G 1

Heavy fuel-oil, slurries, distillates which are not liquid at ambient temperature,

asphalt, paraffins

F 2

Oil H 2

Aromatic solvent (benzene, toluene, …), MEK, Diester S 1

Slops R 1

Chemical products (acid, base) C 1

Water O 1

Various : MTBE, ETBE, liquid sulphur, Alcohol, … X 1

Physical Acoust ics Ltd tel: +44 (0) 1954 231612Norman Way fax: +44 (0) 1954 231102Over Cambridge CB4 5QE e-mail: [email protected]