taylortaylor metal products is providing the following details as an aid in design. the details in...
TRANSCRIPT
MS-200™ FM Installation Guide
BUTYL INJECTED SEAL(AVAILABLE)
2"
BUTYL INJECTED SEAL(AVAILABLE)
2"
TAYLORM E T A L P R O D U C T S
Table of ContentsPanel Specifications ................................................................................. FM Floating Panel Clip ................................................................................. Notes To Designer/Installer .......................................................................Taylor Delivery Fleet .....................................................................................Delivery, Will Call & Loading ........................................................................ Alternate Eave – FM Clip ........................................................................... Standard Eave ............................................................................................ Gutter/Hook Eave ....................................................................................... Standard Ridge ........................................................................................... Vented Ridge .............................................................................................. End Dam Attachment .................................................................................. Valley .......................................................................................................... Valley – Low Slope ...................................................................................... Standard Gable .......................................................................................... Alternate Gable .......................................................................................... Sidewall ...................................................................................................... Peak Flashing (R.E.C.) ..............................................................................Vented Peak Flashing (R.E.C.) ..................................................................Pitch Change ............................................................................................. Endwall ...................................................................................................... Vented Endwall .......................................................................................... Saw Cut Endwall ....................................................................................... Back Pan ................................................................................................... Curb Sidewall ............................................................................................ Curb Endwall ............................................................................................. Curb Back Pan / Cricket .............................................................................Eave to Gable Transition .......................................................................Pipe Penetration – on Plate .......................................................................Pipe Penetration – on Rib ..................................................................... Pipe Penetration – on Pan .........................................................................
Flashing Selection ................................................................................
MS-200™ FMFlashing and Details Guide
2-34
5-789
101112131415161718192021222324252627282930
31-3334
35-3637
38-40
TAYLORM E T A L P R O D U C T S
1
MS-200™ FMMECHANICALLY SEAMED
2
TAYLORM E T A L P R O D U C T S
• 12", 14-5/8" & 16" options available
• 24 & 22 gauge Tru-Gauge™ and .032" Aluminum
• Floating clip system: allows for expansion/ contraction of panels in longer lengths
• 2" Mechanical seam rib, 90° or 180°: Factory notching available
• Factory injected Butyl sealant
• Structural panel that will span up to 5'
• Concealed fasteners: fasteners cannot leak
• Manufactured in Sacramento, CA & Salem, OR
• - Code compliance UL Evaluation Report UL ER 25913-01
• UL 580 Class 90 Wind Uplift & UL Class A Fire rated
• UL Construction No. 90, 176, 180, 238, and 238A
• ASTM E-1592 - Structural uniform static air pressure* ASTM 1646 - Water infiltration* ASTM 2140 - Water infiltration* ASTM 1680 - Air infiltration* *requires approved Taylor Metal Product details, consult TMP rep. with application/specification questions
• Weather tightness warrantly available (Contact TMP representative for details)
• 1/2:12 minimum pitch recommended (For lower pitches, please inquire)
• Standard panel lengths 4' to 60' (For longer panels, please inquire)
• 2' Shortcut capability - notched only (Fee applicable)
• Onsite roll forming available for long lengths
• Panel options: Striations, Accent Ribs, and Flat Pan
• Retro-fit systems available
STRIATIONS
ACCENT RIBS 2 Accent ribs for 12" & 14-5/8" panel3 Accent ribs for 16" panel
BUTYL INJECTED SEAL(AVAILABLE)
2"
BUTYL INJECTED SEAL(AVAILABLE)
2"
90º SEAM DETAL 180º SEAM DETAIL
PANEL PROFILES
KEY FEATURES
3
These printed chips provide a close representation of the colors. Metal samples are available upon request. Coatings are low gloss 10-15% sheen.SRI = Solar Reflective Index. SRI values listed above are in accordance with ASTM E 1980 and are based on actual testing.***Oil canning is not a cause for material rejection***
3-20
Kynar 500
Commercial-grade metal primer
G-90 galvanizing
24 or 26 guage steel
G-90 galvanizing
Commercial-grade metal primer
Corrosion resistant primer
Kynar 500® paint layer
Commercial-grade metal primerGalvanized G-90 or AZ-50
Base SteelGalvanized G-90 or AZ-50Commercial-grade metal primerCorrosion resistant wash coat
STANDARD COOL KYNAR 500® COLORS
MATERIAL SPECIFICATIONS• 24 gauge Kynar 500® Painted Steel .0236" (Thickness prior to painting) Galvanized G-90 or AZ-50
• 24 gauge bare Zincalume® Plus AZ-55 (No finish warranty – 25 yr. perforation warranty)
• 22 gauge Kynar 500® Painted Steel .029" (Thickness prior to painting)
• .032" Kynar 500® Painted Aluminum
• 22 gauge Rusteel Plus™ (A606)
• 16 and 20 ounce Copper (Please inquire)
• Kynar 500® and substrate testing data available (See website)
• “Oil canning” is an inherent characteristic of roof and wall products, and not a defect, which is not a cause for panel rejection
KEY FEATURES• 20 Standard Colors, 5 Metallic Colors and 4 Specialized Colors
• Kynar 500® Paint System - the ultimate in exterior durability and color retention
• “Cool” color pigments are specially designed to reflect infrared light, reducing heat gain to dwelling, and conform with ENERGY STAR® criteria
• Superior Quality, two coat, 70% resin finish, applied at a 1 mil. thickness
• 40 year residential paint warranty
• 20 and 30 year commercial paint warranty: Contact TMP for warranty specifications
Gla
cier
Whi
te S
RI-8
5
40-Year Residential / 20 and 30 Year Commercial Manufacturer’s Limited Warranty
Sier
ra T
an S
RI-6
0
Parc
hmen
t SR
I-58
Ster
ling
Gre
y SR
I-44
Zinc
Gre
y SR
I-39
Cha
rcoa
l Gre
y SR
I-25
Sadd
le T
an S
RI-3
7
Med
ium
Bro
nze
SRI-3
6
Mus
ket S
RI-3
1
Dar
k Br
onze
SR
I-27
Taho
e Bl
ue S
RI-3
1
Paci
fic B
lue
SRI-2
6
Hem
lock
Gre
en S
RI-3
6
Fore
st G
reen
SR
I-24
Pine
Gre
en S
RI-2
5
Terra
Cot
ta S
RI-4
3
Tile
Red
SR
I-35
Col
onia
l Red
SR
I-37
Ret
ro R
ed S
RI-4
2
Blac
k SR
I-26
Met
allic
Silv
er S
RI-6
0
Cha
mpa
gne
SRI-4
8
Antiq
ue P
atin
a SR
I-40
Cop
per P
enny
SR
I-50
Wea
ther
ed Z
inc
SRI-3
9
16 o
z. a
nd 2
0 oz
. Cop
per
*ple
ase
inqu
ire* P
ure
copp
er
has
no w
arra
nty
Rus
teel
Plu
s™ (A
606)
Rus
teel
Plu
s™ h
as n
o m
etal
lic
coat
ing,
is u
npai
nted
and
has
no w
arra
nty
PREMIUM METALLIC COOL KYNAR® COLORS SPECIALIZED MATERIAL
✦ ✦ ✦ ✦ ✦
✦
✦
✦
1,2 1,2 1,22 1,2 1,2 1,2 1,2 1,2
1,22 1,2 1,2 1,2 1,2 1,2 2 2 1,2
1,2 1 1 1,2 1,2 1,2
RIVERSIDE CA • SACRAMENTO CA • SALEM OR • SEATTLE WA • WOODINVILLE WA • WWW.TAYLORMETAL.COM
Vint
age®
SR
I-19
Vint
age®
has
a c
olor
rang
e th
at
can
vary
from
bat
ch-to
-bat
ch.
See
TM
P w
ebsi
te fo
r mor
e in
fo
Zinc
alum
e® P
lus
No
finis
h w
arra
nty
– 25
yr.
perfo
ratio
n w
arra
nty
Width Gauge Color LBS SQFT LBS LF14-‐5/8" 24 1 1.36 1.6518" 24 2 1.28 1.9318" 22 1.61 2.42
15-‐3/8" .032 Alum 0.6 0.9
Standard Panels
FM Approvals Class: 4474 Factory Mutual Rated: 1-120 A SH
1-120 (Wind Uplift), E108 A (Flame Spread) & SH (Severe Hail)
UL 580 Class 90 Wind Uplift Rated UL Class A Fire Rated
Clip Placement: 24" on center, per FM Testing CriteriaPanel Widths: 12", 14-5/8" & 16" only
Taylor Metal Products MS-200TM - SFS FM
Floating Panel Clip w/ injected sealant
4
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
5
MS-200™FMFlashing and Details Guide
TAYLORM E T A L P R O D U C T S
Notes to Designer/Installer
Taylor Metal Products is providing the following details as an aid in design. The details in this guide are not inclusive to all design situations. The designer/installer is responsible for modifications and should take into consideration all aspects of the project including climate conditions, such as, snow and wind, as well as, building code requirements, building design, building usage and maintenance requirements.
Installation should be performed only by qualified installers familiar with metal roofing systems and industry standards. For details not shown in this guide, refer to the Sheet Metal and Air Conditioning Contractors National Association (SMACNA) architectural sheet metal manual for proper design. For manufacturer’s weather tightness warranties – all details must be preapproved by Taylor Metal Products technical representative.
The Standard gauge for all products in this guide is 24 gauge and the standard finish is Kynar 500®. We recommend specifying all flashings be the same gauge, color, and finish as the panels to insure long-term durability and color match.
SubstratesDetails in the manual are all shown over solid substrate. MS-200™ FM can be used over spaced purlins. For solid substrate, Taylor Metal Products recommends 5/8" plywood or metal decking. Contact a TMP representative with questions about panel attachment to varying substrates.
UnderlaymentMinimum underlayment requirements are 30 lb. ASTM rated felt, a synthetic underlayment with Class A and ASTM UV protection technology or a high temperature self-adhering rubberized membrane. When choosing the underlayment, consider the roof slope, roof design, roof panel, and the climate.
Drag Load RequirementsAll panels must be pinned at one end to resist the drag load caused by snow loads, live loads, and the weight of the panel. Drag load is a function of roof slope, actual load and length of panels. Contact Taylor Metal Products for specific drag load requirements.
MS-200™FM Installation Guide - 2020
6
MS-200™FMFlashing and Details Guide
TAYLORM E T A L P R O D U C T S
Ventilation/InsulationIt is the responsibility of the designer to determine the material types needed to control condensation and to insulate and ventilate the roof system. Applications over rigid insulation may require blocking for solid attachment and framing the perimeter for installation of perimeter flashings.
Oil CanningFlat metal surfaces will display waviness commonly referred to as “oil canning.” Oil canning is caused by a variety of conditions. Steel mill tolerances, variations in or uneven substrates and roofing underlayments. Oil canning is a characteristic of metal roofing, not a defect and is not a cause for rejection. Taylor Metal Products offers MS-200™ with striations or accent ribs to help minimize oil canning.
Thermal MovementThe Panels and the flashings must be allowed to expand and contract, especially with longer length panels. The panel may need to have a slight gap where the panel hooks the offset cleat to allow for thermal movement of the panels.
Snow DesignThe following details do not address all conditions for snow environments. Consult with the designers, engineers, and others for acceptable details to accommodate your project and climate conditions. When possible gutters, valleys, pitch changes or other penetrations should be minimized in snow areas.
All roof penetrations should be located as close to the ridge or “pin point” top of roof. Snow country requires special designs for valleys to accommodate accumulation of snow and ice from uphill panels. Roof design should be considered in snow areas. Roof design should help resist the melting and freezing of snow and ice.
A fit for purpose roof design has the greatest impact on maintaining a damage free roof system in snow areas. Please contact a Taylor Metal Products representative for assistance in detail designs and appropriate panel selection for specific climate and building conditions.
MS-200™FM Installation Guide - 2020
MS-200™FMFlashing and Details Guide
7
TAYLORM E T A L P R O D U C T S
Handling / Storage & SafetyHandle materials with care when off-loading or moving materials to avoid damage to panels or flashings. Long panels may require two or more pick-up points, properly spaced to avoid damaging panels. Plan ahead; contact Taylor Metal Products for recommendations on handling/hoisting long panels.
Store the panels, flashings and accessories in a dry, well ventilated area, off the ground. If covering, allow ventilation around panels. Elevate one end of bundle to allow drainage of wet materials.
Wear clean, soft-soled shoes when walking on roofing panels to avoid damage to the painted finish.
Take care that sand, gravel, dirt, etc. sticking to your shoes is not carried onto the roof, scratching or otherwise damaging the finish on the roofing material. Walking on asphalt impregnated felt paper, especially on a hot day, can cause the asphalt to stick to your shoes and be tracked on to the roofing material.
Take care when painting to avoid getting over spray on the roofing material. Remember that wind can carry paint particles some distance. Over spray can cause the finish of the roofing material to look dull and may void your warranty.
Secure materials, especially when leaving the site, on the ground or roof to prevent winds from moving the materials. Wind-blown materials may cause damage to the material, property or persons.
Always use proper safety equipment and attire to minimize risk of cuts or other injuries.
Do not walk on panels that have not been completely installed.
Do not walk on major ribs of panels.
Metal roofs that are wet or dusty can be extremely slippery. Wear soft soled shoes and a safety harness to minimize risk of falling.
Avoid installing metal panels in windy conditions.
Safety considerations are the responsibility of the installer and his crew. Be sure to and use common sense generally accepted safety practices when installing roofing materials.
MS-200™FM Installation Guide - 2020
8
TAYLORM E T A L P R O D U C T S
Taylor Delivery FleetDelivery FleetTaylor Metal Products prides itself with quick lead times delivered with our fleet of semi trucks. Our fleet of trucks are owned and operated by TMP. All of our drivers are Taylor Metal Products employees, so when your truck rolls in to deliver, you are dealing with Taylor Metal Products. Expect consistant and exceptional service with short lead times. The inhouse fleet allows for efficient and cost-effective delivery.
Mounted on the rear of our truck's trailer, the trailer-mounted "Piggy-Back" forklift will accompany you right to your place of use, opening up unprecedented possibilities in terms of transportation. It can travel sideways, carrying panels up to 40' long, allowing delivery in locations that would typically be considered impossible to reach.Save time and effort while avoiding potential loading and transport issues; have experienced TMP personnel deliver and unload your order.
MS-200™FM Installation Guide - 2020
9
TAYLORM E T A L P R O D U C T S
Delivery, Will Call & Loading
Will Call & LoadingFlatbed trailers and trucks are best suited to transport metal roofing materials. These can be loaded from the side with a forklift and tied down in a safe and secure manner.
We are not able to load materials onto vehicles and/or trailers which are not suitable or may be hazardous to load. Please be aware that if we find a vehicle to be inappropriate, we reserve the right to refuse to load your order.
Unacceptable examples include: boat trailers, vans, buses, motor homes, campers and box trailers. Pickup racks which do not have sufficient supports for the weight or are not long enough to support bundles are also unacceptable.
Taylor Metal Products is not responsible to tie down loads nor do we provide any tie down materials. Please bring tie downs to secure your load (string or twine are not acceptable for this purpose).
Consider having your order delivered on one of our trucks with a piggy back forklift.
DeliveryWe will make every attempt to deliver material to the desired location. We may be unable to gain access on tight corners or steep terrain. If the site is deemed inaccessible by our driver, the customer may choose an alternate delivery site within a reasonable proximity. If we are unable to make the delivery, additional charges may be assessed.
The customer is responsible for:• Determining adequate access for delivery
ahead of time.• Meeting the delivery at the agreed upon
time.• Providing adequate resources (1-4 people
as needed) for off loading materials.• A charge of $100 per hour may be added
for deliveries that go beyond their allotted time
• Checking the shipment at the time of delivery.
• Verifying material quantities against the shipping/packing list.
• Noting any damage or discrepancies upon the paper work at the time of delivery and notifying Taylor Metal Products within 48 hours of delivery.
Delivery times are usually scheduled one day in advance. Taylor Metal Products will make every effort to make the delivery at the scheduled time. Please be aware that there may be conditions beyond our control such as traffic, mechanical failures, road closures, etc. which may affect our schedule.
MS-200™FM Installation Guide - 2020
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.10
Alternate Eave – Use With FM Clip TAYLOR
M E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
12"
FIRST CLIP 12"FROM EAVE
#10 SCREW 8" O.C.
LAP ICE & WATEROVER SCREW
DOUBLE ROW OFNON-SKINNING GUNNABLEBUTYL
9" STRIP OFICE & WATERUNDER EAVE
HOOK EAVE
#14 DEKFAST SCREW2 PER CLIP
IF PAINTED,THIS SIDE
112"
1"
112"
SPECIFY PITCH
58" KICK,
12" HEM,
OPEN
3"
34"
38"
151°
HOOK EAVE
FASCIA BOARD
SHEATHING
ICE & WATER
MS200 PANEL
FIRST CLIP12" FROM EAVE
NON -SKINNINGGUNNABLEBUTYL
2" GAPIN SEALANT
#10 SCREW 8" O.C.
RUN ADDITIONAL SEALANTUP MALE PANEL RIB 8"
#14 Dekfast Screw2 Per Clip
SEALANT REQUIREDUNDER FLAT ASSHOWN IN WET
ENVIRONMENTS ONLY(COASTAL / MARINE AND
WEST CASCADE MTNS)
9" ICE & WATER STRIP
ALTERNATE EAVE DETAIL
ALT. EAVE(MS200EH)
MS200 - FMFlashing and Details GuideAlt Eave - For Use with FM Clip
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
11
Standard Eave TAYLOR
M E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
338"
112"
IF PAINTED,THIS SIDE
SPECIFY PITCH
58" KICK,
12" HEM,
OPEN
STANDARD EAVE
FASCIA BOARD
SHEATHING
ICE & WATER SHIELD
MS200 PANEL
FIRST CLIP12" FROM EAVE
NON -SKINNINGGUNNABLEBUTYL
2" GAPIN SEALANT
#10 SCREW 8" O.C.
RUN ADDITIONAL SEALANTUP MALE PANEL RIB 8"
#14 Dekfast Screw2 Per Clip
SEALANT REQUIREDUNDER FLAT ASSHOWN IN WET
ENVIRONMENTS ONLY(COASTAL / MARINE AND
WEST CASCADE MTNS)
9"STRIP ICE & WATER SHIELD
SCREW 8" O.C.
LAP UNDERLAYMENTOVER SCREW
DOUBLE ROW OFSEALANT
9" STRIP OFUNDERLAYMENT
UNDER EAVE
STANDARD EAVE
22 GA OFFSET CLEAT
SEALANT
LAP UNDERLAYMENTOVER SCREW
38"
STANDARD EAVE
MS200-FMFlashing and Details GuideEave / Hook Eave
STANDARD EAVE DETAIL
12
Gutter / Hook Eave
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
512"
1"
6"
34"
12" HEM,
OPEN
4"
1"
314"
IF PAINTED,THIS SIDE
2X 108°53
8"
1"1316"
58"
12"
FIRST CLIP 12"FROM EAVE
SCREW 8" O.C.
LAP ICE & WATEROVER SCREW
DOUBLE ROW OFNON-SKINNING
GUNNABLE BUTYL
9" STRIP OFICE & WATERUNDER EAVE
GUTTER HANGER30" O.C.
BOXGUTTER
NEOPRENE WASHEREDSCREW 30" O.C.
GUTTER TAPEREDTO DOWNSPOUT
#14 DEKFAST SCREW2 PER CLIP
MS200 PANEL
ATL. EAVE
IF PAINTED,THIS SIDE
112"
1"
112"
SPECIFY PITCH
58" KICK,
12" HEM,
OPEN
3"
34"
38"
151°
SHEATHING
HOOK EAVE
9" ICE & WATER STRIP
FASCIA BOARD
MS200
ICE & WATER SHIELD
FIRST CLIP12" FROM EAVE
2" GAPIN BUTYL
NON-SKINNINGGUNNABLE
BUTYL
#10 SCREW 8" O.C.
GUTTER HANGER
BOX GUTTER
#14 DEKFAST SCREW2 PER CLIP
SEALANT REQUIRED UNDER FLATAS SHOWN IN WET
ENVIRONMENTS ONLY(COASTAL / MARINE AND
WEST CASCADE MTNS)
HOOK EAVE WITHGUTTER DETAIL
BOX GUTTER(MS200BG)
MS200 - FMFlashing and Details GuideGutter / Hook Eave
BOX GUTTER HANGER(AGH6)
HOOK EAVE(MS200EA)
13
Standard Ridge
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
SPECIFYPITCH
IF PAINTED,THIS SIDE
1" HEM,OPEN
7"
1"
4" LAP
3 ROWS OF SKINNINGGUNNABLE BUTYL
NEOPRENE WASHEREDSCREW
4"
MS200PANEL
STANDARD RIDGENEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
INTO END DAM(AVOID STANDING SEAM)
SHEATHING
ICE AND WATER SHIELD
NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE
DOUBLE BEADBUTYL TAPE
SCREW END DAMTO SEAM
DOUBLE BEAD BUTYLTAPE TAB
HAT FLASHING /END DAM SUPPORT
112"
34"
38"
12"
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED,FILL ALL VOIDS ON FRONT SIDEOF END DAM WITH SEALANT
DOUBLE BEAD BUTYL TAPE
SEALANT ON TOP OF RIBTO FILL GAPS STANDARD RIDGE
(MS200RS)
MS200 - FMFlashing and Details GuideStandard Ridge
STANDARD RIDGE DETAIL
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
END DAM DETAIL
STANDARD RIDGE LAP
14
Vented Ridge
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
8"
112"
58"
12" HEM,
OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
4X 120°
3 ROWS OF SKINNINGGUNNABLE BUTYL
NEOPRENE WASHEREDSCREW 4" O.C.
1"
4" LAP
SHEATHING
MS200 PANEL
DOUBLE BEADBUTYL TAPE
SCREW END DAMTO SEAM
ICE & WATER SHIELD
VENTED RIDGE
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
TEK SCREW INTOEACH PANEL RIB
4" PERFORATEDSTRIP
NEOPRENEWASHEREDSCREW OR RIVETAT 12" O.C. INTOEACH END DAM.(AVOID STANDING SEAM)
DOUBLE BEADBUTYL TAPE
ON TAB
TRIPLE BEADBUTYL TAPE
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED,FILL ALL VOIDS ON FRONT SIDEOF END DAM WITH SEALANT
DOUBLE BEAD BUTYL TAPE
SEALANT ON TOP OF RIBTO FILL GAPS
112"
34"
38"1
2"
MS200 - FMFlashing and Details GuideVented Ridge
VENTED RIDGE DETAIL
VENTED RIDGE(MS200RFV)
END DAM DETAIL
VENTED RIDGE LAP
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
End Dam Attachment
15
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED ,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIBTO FILL GAPS
SCREW END DAM TO PANEL RIB
SEALANTUP SIDES OF RIB
AND ON TOP.
END DAM
END DAM SEALANT
SHEATHING UNDERLAYMENT
MS200 PANEL
SCREW END DAMTO PANEL RIB
SEALANT TO FILL GAPS
NEOPRENE WASHERED 1" FROM SIDE OF RIBAND 4" O.C.
HAT FLASHING
MS200 - FMFlashing and Details GuideEnd Dam Attachment
4" MIN
FIRST CLIP 12"FROM VALLEY
22 GA. OFFSETCLEAT, SCREWED
8" O.C.
DOUBLE BEADBUTYL TAPE
NON-SKINNINGBUTYL CAULK
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENT
#14 DEKFAST SCREW2 PER CLIP
SEALANT 8"FROM EAVE
HAT FLASHING(OR 3 8" PLYWOOD)
11"1"
IF PAINTED,THIS SIDE
SPECIFYPITCH
112"
1"
12"
THREE ROWS OFSKINNING
GUNNABLE BUTYLAT LAP JOINT
6"LAP
1"
112"
34"
38"
12"
VALLEY DETAIL
VALLEY(MS200VF)
OFFSET CLEAT(MS200OC)
VALLEY LAP
MS200 - FMFlashing and Details GuideValley Flashing - 3:12 Slope or Greater
(3:12 or Greater Pitch)
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
(3:12 or Greater Pitch)
16
Valley FlashingSlope 3:12 or Greater
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
11"1"
IF PAINTED,THIS SIDE
SPECIFYPITCH
THREE ROWS OFSKINNING
GUNNABLE BUTYLAT LAP JOINT
12"LAP
1"
4"
FIRST CLIP 12"FROM VALLEY
DOUBLE BEADBUTYL TAPE
THREE ROWS OFSKINNING
GUNNABLE BUTYL
NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.ICE & WATER SHIELD
LAP ICE & WATER OVER SCREW
#14 DEKFAST SCREW2 PER CLIP
HAT CHANNEL(OR 3 8" PLYWOOD)
LOW SLOPE VALLEY DETAIL
VALLEY FLASHING(MS200VF)
LOW SLOPE VALLEY LAP
MS200 - FMFlashing and Details GuideValley Flashing - Low Pitch 3:12 or Lower
(Less Than 3:12 Pitch - Not Recommended)
(Less Than 3:12 Pitch - Not Recommended)
17
Valley Flashing - Low Slope Slope Less than 3:12 (Not Recommended)
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
18
Standard Gable
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
DOUBLE BEADBUTYL TAPE
SUPPORT FLASHING
SCREW 8" O.C. WITHSEALANT OVER TOP
ICE & WATER SHIELDWRAPPED DOWNFACE 3"
NEOPRENE WASHEREDSCREW 12" O.C.
UPEND PANEL2" AT 90°
STANDARD GABLE
SHEATHING
FASCIA
134"
134"
438"
58" KICK,
12" HEM,
OPEN
IF PAINTED,THIS SIDE
1"
238"
3"
IF PAINTED,THIS SIDE
34"
12"
38"
ICE & WATER SHIELDWRAPPED DOWN FACE 3"
SHEATHING
FASCIA
SUPPORTFLASHING
SCREWWITH SEALANTOVER THE TOP
MS200PANEL
BEND PANEL1" AT 90°
NEOPRENE WASHEREDSCREW OR RIVET
STANDARDGABLE
SEALANT
STD. GABLE(MS200GS)
SUPPORT FLASHING(MS200SF)
MS200 - FMFlashing and Details GuideStandard Gable
STANDARD GABLE DETAIL
19
Alternate Gable
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
212"
438"
58" KICK,
12" HEM,
OPEN
IF PAINTED,THIS SIDE
12"
1"
414"
12" KICK
IF PAINTED,THIS SIDE
1"
238"
3"
IF PAINTED,THIS SIDE
12"
34"
38"
1"
134"
12" HEM,
OPEN
IF PAINTED,THIS SIDE
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
SUPPORT FLASHING
SCREW 8" O.C. WITHSEALANT OVER TOP
CLEAT SCREW24" O.C.
UPEND PANEL2" AT 90°
ALT. GABLE
SHEATHING
FASCIA
ICE & WATER SHIELDWRAPPED DOWNFACE 2"
DOUBLE BEADBUTYL TAPE
CONTINUOUS CLEAT
ALT. L CLOSURE
ALTERNATE GABLE DETAIL
ALT. L CLOSURE(MS200ALC)
SUPPORT FLASHING(MS200SF)
ALT. GABLE(MS200AG)
GABLE SUPPORT CLEAT(MS200GC)
MS200 - FMFlashing and Details GuideAlternate Gable
Sidewall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.20
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
ICE & WATER SHIELDTURN UP WALL 8"
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
SCREW 8" O.C. WITHSEALANT OVER THE TOP
SUPPORTFLASHING
BEND PANELEDGE AT 90°
DOUBLE BEADBUTYL TAPE
WALL PANEL/SIDING
SHEATHING
SIDEWALL
MS200 PANEL
414"
134"
134"
IF PAINTED,THIS SIDE
12" HEM,
OPEN
1"
238"
3"
IF PAINTED,THIS SIDE
12"
34"
38"
SHEATHING
WALL PANEL
SEALANT
SUPPORTFLASHING
MS200PANEL
SIDEWALLICE & WATER
TURN UP WALL 8"
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
BEND PANELEDGE 1" AT 90°
SIDEWALL DETAIL
SUPPORT FLASHING(MS200SF)
SIDEWALL(MS200SW)
MS200 - FMFlashing and Details GuideSideWall
21Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
Peak Flashing (Ridge End Cap)
514"
12" KICK
IF PAINTED,THIS SIDE
1"
SPECIFYPITCH
7"
538"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1" HEM,OPEN
58" KICK,
12" HEM,
OPEN
4" LAP 1"
4"
LAP 4" WITH 3 ROWSNON-SKINNINGGUNNABLE BUTYL
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED ,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIBTO FILL GAPS
112"
34"
38"
12"
MS200PANEL
PEAK FLASHING
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
INTO EACH END DAM(AVOID STANDING SEAM)
SHEATHING
ICE & WATER SHIELD
NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OFRIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE
DOUBLE BEADBUTYL TAPE
CLEAT SCREW 12" O.C
CONTINUOUS CLEAT
HAT FLASHING(OR 3 8" PLYWOOD)
MS200 - FMFlashing and Details GuideRidge End Cap
PEAK FLASHING(MS200REC)
PEAK CLEAT(MS200RECC)
PEAK FLASHING DETAIL(Ridge End Cap)
PEAK FLASHING LAP
END DAM DETAIL
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
22
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
Vented Peak Flashing (Vented Ridge End Cap)
SHEATHING
MS200PANEL
DOUBLE BEADBUTYL TAPE
SCREW END DAMTO SEAM TAB
ICE & WATER SHIELD
VENTEDPEAKFLASHING
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND
4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
TEK INTOEACH PANEL RIB
4" PERFORATED STRIP
NEOPRENE WASHEREDSCREW OR RIVET AT 12"
O.C. INTO EACH END DAM.
10" - VARIES PER SLOPE
VENTEDPEAKCLEAT
FASCIA
NEOPRENE WASHEREDSCREW OR RIVET AT
CENTER OF END DAM(AVOID STANDING SEAMS)
CLEATSCREW12" O.C.
DOUBLE BEADBUTYL TAPE
ON TABS
DOUBLE BEADBUTYL TAPEON TABS
HAT FLASHING(OR 3 8" PLYWOOD)
514"
12" KICK
IF PAINTED,THIS SIDE
1"
SPECIFYPITCH
6"
10"
58"
112"
IF PAINTED,THIS SIDE
SPECIFYPITCH
12" HEM,
OPEN5
8" KICK,1
2" HEM,OPEN
4" LAP 1"
4"
NEOPRENEWASHERSCREWS
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED ,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIBTO FILL GAPS
112"
34"
38"1
2"
MS200 - FMFlashing and Details GuideVented Ridge EndCap
PEAK FLASHING(MS200SW)
VENTED PEAK FLASHING DETAIL(Vented Ridge End Cap)
PEAK CLEAT(MS200RECC)
VENTED PEAK FLASHING LAPEND DAM DETAIL
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
23
Pitch Change
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
4" LAP1" BUTYL GAP
THREE ROWS OF SKINNINGBUTYL AT LAP JOINT
4"
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
12"
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIB
TO FILL GAPS
1"
12"
112"
112"
34"
38"1
2"
NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.INTO END DAM( AVOID STANDING SEAM)
DOUBLE BEADNON-SKINNINGGUNNABLE BUTYL
SHEATHING
ICE & WATER SHIELD
MS200 PANEL
PITCH CHANGE
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND
4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
22 GA OFFSET CLEAT
#10 SCREW8" O.C.
DOUBLE BEADBUTYL TAPE
HAT FLASHING(OR 3 8" PLYWOOD)
DOUBLE BEADBUTYL TAPE
MS200 - FMFlashing and Details GuideRoof Pitch Transition
PITCH CHANGE LAP
INSIDE PITCH CHANGE FLASHING
END DAM DETAIL
OFFSET CLEAT(MS200OC)
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
PITCH CHANGE DETAIL
24
Endwall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
5"
6"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1" HEM,OPEN
MS200PANEL
WALL PANEL
112"
34"
38"
12"
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED ,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIBTO FILL GAPS
ICE & WATER SHIELDOVER SCREW
ICE & WATER SHIELDUP WALL 8" PASTFLASHING
NEOPRENE WASHERED SCREWOR RIVET AT 12" O.C.INTO EACH END DAM(AVOID STANDING SEAM)
WALL PANEL
MS200 PANEL
SCREW END DAMTO SEAM
NEOPRENE WASHERED DRAG LOAD1" FROM SIDE OF RIB AND 4" O.C. MIN.DRAG LOAD CALCULATIONS MAY REQUIRE MORE.
HAT FLASHING(OR 3 8" PLYWOOD)
DOUBLE BEADBUTYL TAPE
MS200 - FMFlashing and Details GuideRoof EndWall
ENDWALL(MS200EW)
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
ENDWALL DETAIL
END DAM DETAIL
ENDWALL DETAIL
438"
7"
58"
112"
SPECIFYPITCH
2X 135°
IF PAINTED,THIS SIDE
12" HEM,
OPEN
112"
34"
38"
12"
MS200PANEL
WALL PANEL
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED ,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIBTO FILL GAPS
WALLPANEL
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
TEK SCREW INTOEACH PANEL RIB
NEOPRENE WASHEREDSCREW OR RIVET AT 12"O.C. INTO EACH END DAM.(AVOID STANDING SEAM)
NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.
INTO EACH END DAM
4" PERFORATEDSTRIP
ICE & WATER SHIELDOVER SCREW
HAT FLASHING(OR 3 8" PLYWOOD)
ICE & WATER SHIELD
DOUBLE BEADBUTYL TAPE
SHEATHING
MS200 - FMFlashing and Details GuideVented EndWall
VENTED ENDWALL LAP
VENTED ENDWALL(MS200EWV)
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
END DAM DETAIL
VENTED ENDWALL DETAIL
25
Vented Endwall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
26
Endwall w/ Saw Cut Reglet
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
SHEATHING
MS200PANEL
ICE & WATER SHIELD
NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.
INTO EACH END DAM(AVOID STANDING SEAM)
DOUBLE BEADBUTYL TAPE
TUCK REGLET INTOSAW CUT, SET IN SEALANT
FASTENER24" O.C.
DOUBLE BEADBUTYL TAPE
ON TABS
HAT FLASHING(OR 3 8" PLYWOOD)
112"
34"
38"
12"
3 ROWS OF SEALANTGUNNABLE BUTYLAT LAP JOINT
NEOPRENEWASHERED
SCREW
4" LAP 1"
4"
5"
6"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1" HEM,OPEN
358"
1"1
2" HEMAT 30°
IF PAINTED,THIS SIDE
12" HEM,
OPEN
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED ,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIBTO FILL GAPS
MS200 - FMFlashing and Details GuideSaw Cut EndWall
ENDWALL LAP
SAW CUT ENDWALL DETAILREGLET
(MS200RF)
ENDWALL(MS200EW)
END DAM DETAIL
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
27
Back Pan & Soldered Back Pan
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
TAB SIDE WALL TO RECEIVE PANTAB AND RIVET BACK PAN
ENSURE END DAM UNDER SIDE WALL IS SEALEDFILL ALL VOIDS WITH SEALANT
HOOK BACK PAN TO OFFSET CLEAT
Z-CLOSURE
TAB SIDE WALL TO RECEIVE PANTAB AND RIVET BACK PAN
ENSURE Z-CLOSURE UNDER SIDE WALLIS SEALED, FILL ALL VOIDS WITH SEALANT
HOOK BACK PAN TOOFFSET CLEAT
Z-CLOSURE
1812"
512"
MS200 - FMFlashing and Details GuideBack Pan & Soldered Back Pan
BACK PAN DETAIL
SOLDERED BACK PAN / CRICKET DETAIL
BACK PAN(MS200PAN)
28
Curb Sidewall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
4"
4"
134"
IF PAINTED,THIS SIDE
12" HEM,
OPEN1"
1"
IF PAINTED,THIS SIDE
178" 11
2"
34"
38"
12"
WALLPANEL
LAP UNDERLAYMENTOVER SCREW
ICE & WATER SHIELDUP WALL 8"
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
DOUBLE BEADBUTYL TAPE
CURB SIDEWALL
ZEE CLOSURE
NEOPRENE WASHEREDSCREW 8" O.C.
MS200 PANEL
SHEATHING HAT FLASHING(OR 3 8" PLYWOOD)
MS200 - FMFlashing and Details GuideCurb SideWall
CURB SIDEWALL(MS200CSW)
ZEE CLOSURE(MS200ZC)
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
CURB SIDEWALL DETAIL
29
Curb Endwall
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
5"
6"
IF PAINTED,THIS SIDE
1" HEM,OPEN
MS200PANEL
WALL PANEL
112"
34"
38"
12"
SCREW ENDDAM TO PANEL
AFTER END DAM IS INSTALLED,FILL ALL VOIDS IN BACK SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL
DOUBLE BEADBUTYL TAPE
SKINNING GUNNABLEBUTYL ON TOP OF RIB
TO FILL GAPS
SCREW END DAMTO SEAM
SHEATHING
MS200PANEL
ICE & WATER SHIELD
NEOPRENE WASHEREDDRAG LOAD 1" FROMSIDE OF RIB AND4" O.C. MIN. DRAG LOADCALCULATIONSMAY REQUIRE MORE.
NEOPRENE WASHEREDSCREW OR RIVET AT 12" O.C.
INTO EACH END DAM(AVOID STANDING SEAMS)
DOUBLE BEADBUTYL TAPE
LAP ICE & WATER SHIELDOVER SCREW
ICE & WATER SHIELDUP WALL 8"
DOUBLE BEADBUTYL TAPE
ON TABS
HAT FLASHING(OR 3 8" PLYWOOD)
MS200 - FMFlashing and Details GuideCurb End Wall
CURB ENDWALL(MS200CH)
22 ga HAT FLASHING FOR USE WITH FM CLIP
(OR 3 8" PLYWOOD)
ENDWALL DETAIL
END DAM DETAIL
CURB ENDWALLDETAIL
30
Curb Back Pan / Cricket
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable butyl.
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
4" MIN
FIRST CLIP 12"FROM VALLEY
22 GA. OFFSET CLEAT,SCREWED 8" O.C.
DOUBLE BEADBUTYL TAPE
DOUBLE ROW OFNON-SKINNING
GUNNABLE BUTYL
LAP ICE & WATER SHIELDOVER SCREW
RUN ICE & WATERUP CURB 8"
CURB BACKPAN
CRICKET WHEN CURBIS WIDER THAN 24"
CURB BACK PAN / CRICKET DETAIL(3:12 Pitch or Greater)
4"
FIRST CLIP 12"FROM VALLEY
TRIPLE BEADBUTYL TAPE
THREE ROWS OFSKINNING
GUNNABLE BUTYL
NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.
ICE & WATER SHIELD
LAP ICE & WATER OVER SCREW
#14 DEKFAST SCREW2 PER CLIP
HAT CHANNEL(OR 3 8" PLYWOOD)
CURB BACK PAN / CRICKET DETAIL( Less Than 3:12 Pitch)
MS200 - FMFlashing and Details GuideCurb Pan / Cricket3
12 Slope or Greater
31
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
BEND UP 90°
CUT
REMOVE
BEND DOWN 90°CUT
MS200 PANELSHOWN
Eave to Gable Transition
EAVE TO GABLE TRANSITION
STEP 1
BEND UP 90°
CUT
REMOVE
BEND DOWN 90°CUT
MS200 PANELSHOWN
32
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
TABBED EAVE
UNDERLAYMENT
HOOK EAVE
SUPPORTFLASHING
REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.
FASCIA BOARD,EAVE
FASCIA BOARD,RAKE
1"
PANCAKESCREW
STEP 2
TABBED EAVE
UNDERLAYMENT
HOOK EAVE
SUPPORTFLASHING
REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.
FASCIA BOARD,EAVE
FASCIA BOARD,RAKE
1"
PANCAKESCREW
Eave to Gable Transition
33
Note: All screws must be fastened into solid substrate. Flashing must be lapped 4" with 3 rows of gunnable sealant.
TAYLORM E T A L P R O D U C T S
MS-200™ Installation Guide - 2020
NOTCH GABLEAROUND EAVE.
SUPPORTFLASHING
GABLE
FOLD PANELAROUNDHOOK EAVE.
CAP GABLEAND SEAL.
PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANELINSIDE CLOSURE.
PLACE FOLD AGAINSTHOOK EAVE FLASHING.
STEP 4
STEP 3
Eave to Gable Transition
NOTCH GABLEAROUND EAVE.
SUPPORTFLASHING
GABLE
FOLD PANELAROUNDHOOK EAVE.
CAP GABLEAND SEAL.
PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANELINSIDE CLOSURE.
PLACE FOLD AGAINSTHOOK EAVE FLASHING.
SEAL
ROOFPANEL
ICE & WATERSHIELD
22 GA PLATEFASTENED TO DECK
BOTTOM OF RIVET.DO NOT PENETRATE
PLATE.
SOLID SHANKWATERPROOF RIVET
FOR PIPES LOCATED OVER 20' FROM PIN POINT
DOUBLE BEADBUTYL TAPE
SS HOSE CLAMP
TWO TYPES OF PLATES YOU CAN USE:
SINGLE PLATE TWO HALF-PLATES
MS200 - FMFlashing and Details GuidePipe Penetration - Plate
34
Pipe Penetration - on Plate TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
(Allows panel and pipe flashing to move with temperature change.)
35
Pipe Penetration - on RibTAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
DOUBLE BEAD BUTYL TAPE
SCREW ZEE CLOSURE4" O.C. MINIMUM
SEAL EXTERIOROF ZEE CLOSURES
1" TAB WITH FASTENER.FASTEN TO SEAM IF POSSIBLE.SEAL WITH CAULKING.
ANGLE TABON EXTERIOR, FASTENED
DOUBLE BEAD BUTYL TAPE
CUT HOLE IN PANELAT LEAST 1" LARGERTHAN PIPE
USE ICE AND WATER SHIELDTO SEAL AROUND PIPE
BUTYL TAPE UP SIDESAND TOP OF SEAM
PRE-SEALBETWEEN SEAMS
MS200 - FMFlashing and Details GuidePipe Penetration - On Rib
36
Pipe Penetration - on Rib TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
SET HOSE CLAMPAT TOP OF PIPE
BOOT AND SEAL WITHUV RESISTANT SEALANT
NEOPRENE WASHEREDSCREW 11
4" O.C. MINIMUM
PIPE BOOT
BEAD OF SEALANT
DOUBLE BEAD BUTYL TAPE
CUT HOLE 1"LARGER THAN PIPE
NEOPRENE WASHEREDSCREW 4" O.C. MINIMUM
12" DOWNTURN
ON CAP. ORHEM BACK OVER
ZEE CLOSURE
MS200 - FMFlashing and Details GuidePipe Penetration - On Rib
SET HOSE CLAMP AT TOPAND USE UV RESISTANT SEALANT
NEOPRENE WASHEREDSCREW 11
4" O.C.
PIPE BOOT
2" MIN
NOTE: ALLOW A MINIMUM OF2" BETWEEN THE BASE OFTHE PIPE FLASHING AND THESTANDING SEAM.
BEAD OF SEALANT
DOUBLE BEAD BUTYL TAPECUT HOLE 1"
LARGER THAN PIPEAND SEAL WITH
UNDERLAYMENT
MS200 - FMFlashing and Details GuidePipe Penetration - On Pan
37
Pipe Penetration - on PanTAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
MS-200™ FMFlashing and Details SelectionFlashing: 10' Standard
38
TAYLORM E T A L P R O D U C T S
112"
1"
438"IF PAINTED,
THIS SIDE
SPECIFY PITCH
58" KICK,
12" HEM,
OPEN
212"
438"
58" KICK,
12" HEM,
OPEN
IF PAINTED,THIS SIDE1
2"
134"
134"
438"
58" KICK,
12" HEM,
OPEN
IF PAINTED,THIS SIDE
512"
4"
314"
1"
1"
34"
IF PAINTED,THIS SIDE
12" HEM,
OPEN
2X 108°
6"
1"
134"
12" HEM,
OPEN
IF PAINTED,THIS SIDE
1"
414"
12" KICK
IF PAINTED,THIS SIDE
1"
238"
3"
34"
12"
38"
338"
112"
IF PAINTED,THIS SIDE
SPECIFY PITCH
58" KICK,
12" HEM,
OPEN
IF PAINTED,THIS SIDE
112"
1"
112"
SPECIFY PITCH
58" KICK,
12" HEM,
OPEN
3"
34"
151°
MS200 - FMFlashing and Details GuideMS200 Flashings (10' Standard)
WEIGHT: 6.5 LBS.S.O. 8"SCALE 1:3
( MS200EH )EAVE HOOK
WEIGHT: 13.3 LBS.S.O. 16"SCALE 1:4
( MS200BG )BOX GUTTER
WEIGHT: 7.6 LBS.S.O. 9.5"SCALE 1:4
( MS200GS )GABLE STANDARD
WEIGHT: 7 LBS.S.O. 8.5"SCALE 1:4
( MS200AG )ALT. GABLE
WEIGHT: 2.5 LBS.S.O. 3.25"SCALE 1:3
( MS200ALC )ALT. L CLOSURE
WEIGHT: 4.7 LBS.S.O. 5.75"SCALE 1:4
( MS200GC )GABLE SUPPORT CLEAT
WEIGHT: 6 LBS.S.O. 7.375"SCALE 1:3
( MS200SF )SUPPORT FLASHING
NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED
WEIGHT: 4.9 LBS.S.O. 6"SCALE 1:3
( MS200ES )EAVE STANDARD
WEIGHT: 7.3 LBS.S.O. 8.875"SCALE 1:3
( MS200EA )ALT. EAVE
MS-200™ FMFlashing and Details Selection
Flashing: 10' Standard
39
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
7"
1" HEM,OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
5"
6"
IF PAINTED,THIS SIDE
SPECIFYPITCH1" HEM,
OPEN
11" 1"
IF PAINTED,THIS SIDE
SPECIFYPITCH
8"
112"
58"
12" HEM,
OPEN
SPECIFYPITCH
IF PAINTED,THIS SIDE
4X 120°
358"
1"1
2" HEMAT 30°
IF PAINTED,THIS SIDE
12" HEM,
OPEN
438"
5"
58"
112"
SPECIFYPITCH
2X 135°
IF PAINTED,THIS SIDE
12" HEM,
OPEN
1"
1"
IF PAINTED,THIS SIDE
178" 57
8" Vented51
4" Standard
1"
12" KICKAT 35°
WEIGHT: 13.2 LBS.S.O. 16"SCALE 1:5
( MS200RS )RIDGE
WEIGHT: 19.7 LBS.S.O. 24"SCALE 1:6
( MS200VF )VALLEY FLASHING
WEIGHT: 16.9. LBS.S.O. 12"SCALE 1:5
( MS200EWV )VENTED ENDWALL
WEIGHT: 17.5 LBS.S.O. 21.25"SCALE 1:6
( MS200RFV )VENTED RIDGE
ZEE CLOSURE( MS200ZC )
SCALE 1:5
WEIGHT: 3.4 LBS.S.O. 3.875"
REGLET( MS200RF )
SCALE 1:5
WEIGHT: 4.8 LBS.S.O. 5.625"
ENDWALL( MS200EW )
SCALE 1:5
WEIGHT: 10.0 LBS.S.O. 12"
PEAK CLEAT( MS200RECC / MS200VRECC )
SCALE 1:5
S.O. 6.75" / 7.375" WEIGHT: 5.9 LBS.
MS200 - FMFlashing and Details GuideMS200 Flashings (10' Standard)
NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED
MS-200™ FMFlashing and Details SelectionFlashing: 10' Standard
40
TAYLORM E T A L P R O D U C T S
MS-200™FM Installation Guide - 2020
7"
538"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1" HEM,OPEN
58" KICK,
12" HEM,
OPEN
6"
6"
58"
112"
IF PAINTED,THIS SIDE
SPECIFYPITCH
12" HEM,
OPEN
58" KICK,
12" HEM,
OPEN
5"
6"
IF PAINTED,THIS SIDE
1" HEM,OPEN
414"
134"
134"
IF PAINTED,THIS SIDE
12" HEM,
OPEN
512"
1812"
IF PAINTED,THIS SIDE
4"4"
4"
134"
IF PAINTED,THIS SIDE
12" HEM,
OPEN
34"
112"
38"
12"
WEIGHT: 10.0 LBS.S.O. 24"SCALE 1:10
( MS200PAN )BACK PAN
WEIGHT: 9.9 LBS.S.O. 12"SCALE 1:5
( MS200CH )CURB ENDWALL
WEIGHT: 2.5 LBS.S.O. 4"SCALE 1:3
( MS200PS )4" PERFORATED STRIP
WEIGHT: 8.3 LBS.S.O. 10.25"SCALE 1:5
( MS200CSW )CURB SIDEWALL
MS200 - FMFlashing and Details GuideMS200 Flashings (10' Standard)
WEIGHT: 7.0 LBS.S.O. 8.25"SCALE 1:3
( MS200SW )SIDEWALL
WEIGHT: 12.0 LBS.S.O. 14.5"SCALE 1:4
( MS200REC )PEAK FLASHING (R.E.C.)
WEIGHT: 13.0 LBS.S.O. 15.75"SCALE 1:5
( MS200RECV )VENTED PEAK FLASHING (R.E.C.)
WEIGHT: VARIESS.O. VARIESSCALE NA
END DAM
WEIGHT: 2 LBS.S.O. 4"SCALE 1:3
( MS200HF )HAT FLASHING
Panels with * need Pattern Choice:□Ribs □Striations □Flat Notched? Y / N Clip Relief? Y / N Sealant? Y / N
Job Name: Ship To: □ Will Call Day:
Order Form □ New Order □ Add-on Order □ Quote
Inside Sale:
PO #: Date:
□ Delivery Delivery Date:
PBRMarion “R” Panel2-1/2" CorrugatedClassic 7/8" CorrugatedGR-7HR-34T-3Tuff-Rib
□□□□□□□□
12" Easy-Lock*16" Easy-Lock*16" StreamLine*12" CL-175*
□□ □□ □ □□□□
Color: Pitch: Gauge: Dmatch: Pallet: 10' 20' 30'
Panel & Flashing Items
Quantity Length Item Description Part # Quantity Length Item Description Part #
4566 Ridge Dr NE • Salem, OR 97301 • F: 503-581-6877 • P: 503-581-8338 • www.taylormetal.com
Forgetting Anything? Underlayment? Screws? Clips? Caulking? Closures?
TAYLORM E T A L P R O D U C T S
Sold To: Order Contact:Phone #:Fax #:
□ Agricultural □ Residential □ Commerical Route:
□□□
ShadowLine**(circle): 1", or 1-1/2" 1/2" to 3" Reveal:
1"x12-5/8" SmoothWall**1"x12-5/8" Lifetime Soffit**
Panels with ** need Pattern Choice: □Striations □Flat □1 V-Groove □2 V-GroovesPerforated?
12-3/8" Slim-Lock*16-1/4" Slim-Lock*12" MS-200*14-5/8" MS-200*16" MS-200*18" MS-200*12-3/4" MS-150*16-5/8" MS-150*20" MS-150*13-3/4" MS-100*17-5/8" MS-100*
□□□□□□□□□ □ □
12" Versa-Span*14-5/8" Versa-Span*16" Versa-Span*18" Versa-Span*15-1/2" T-Panel*
*All Kynar Slim-Lock, Easy-Lock, Lifetime Soffit, SmoothWall, ShadowLine, T-Panel, Versa-Span, CL-175, MS-100, MS-150, & MS-200 flashings are 10'*All ArmorTech StreamLine, T-3, Tuff Rib, GR7, PBR, HR-32, Marion "R", & Corrugated flashings are 12'6"
Flat not available on StreamLine
(Available on Lifetime Soffit Only)
( )Standard Panels are in Bold font.
Please provide a drawing for each flashing with precise measurements and anglesFax to: 503-581-6877
4566 Ridge Dr NE Salem OR 97301 • Phone: 503-581-8338 or 1-800-574-1388 • www.taylormetal.com
Custom Trim OrderTAYLORM E T A L P R O D U C T S
Custom Trim OrderTAYLORM E T A L P R O D U C T S
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Please provide a drawing for each flashing with precise measurements and angles
www.taylormetal.com
Customer Name: Job Name:
Gauge: Color:
TAYLORM E T A L P R O D U C T S
QUALITY PRODUCTSEXCEPTIONAL SERVICE
SALEM BRANCH4566 Ridge Dr. NESalem, OR 97301
Office: 503-581-8338Toll Free: 1-800-574-1388
Fax: 503-581-6877
WOODINVILLE BRANCH5927 234th St. SE
Woodinville, WA 98072
Office: 425-485-3003Toll Free: 855-334-8558
Fax: 425-485-2710
SACRAMENTO BRANCH5711 Perrin Ave
McClellan, CA 95652
Office: 916-318-8844Toll Free: 1-800-574-1388
Fax: 916-993-4123
AUBURN BRANCH710 A. St. NW Suite 101
Auburn, WA 98001
Office: 206-900-9923Toll Free: 1-800-574-1388
Fax: 253-804-3545
RIVERSIDE BRANCH4880 Felspar St.
Riverside, CA 92509
Office: 323-407-7457Toll Free: 1-877-504-1594
MS-200™ FM Installation Guide • ©2020 Taylor Metal Products Revised 3/20