te t mete f - greyline instruments inc. · 2020-06-02 · installation is easy - without shutting...

4
THE RIGHT METER FOR Raw Sewage Aerated Water Return & Waste Sludge Slurries Viscous Liquids Pulp Stock Abrasives Greyline Precision Flow Measurement An ONICON Brand 888-473-9546 greyline.com DFM 6.1 DOPPLER FLOW METER Features Fast, Non-Invasive Installation Simple 5-button Interface 26 million point Data Logger Hazardous Location Certified Sensor Modbus ® RTU or HART Optional Accurate Flow Measurement of “Difficult” Fluids from Outside a Pipe Ideal for “Difficult” Fluids Greyline Doppler Flow Meters monitor the flow rate of dirty or aerated liquids including: wastewater, sewage, slurries, abrasives, and viscous liquids. Recommended for full pipes and any fluid that contains solids or bubbles. External Sensor No Contact, No Maintenance The DFM 6.1 clamp-on sensor is mounted on the outside of any pipe ½ inch / 12.7mm diameter or larger. To measure velocity an acoustic signal is reflected back to the sensor from moving particles or gas bubbles suspended in the fluid. Flow is calculated based on configured pipe ID. Installation is easy - without shutting down the flow system. No contact is made with the moving fluid and no pipe cutting or drilling is required. There is no fouling or scale build-up on the sensor. The DFM 6.1 Doppler Flow Meter includes an ultrasonic sensor, an easy to use 5-key configuration system, a large digital flow rate display with totalizer, isolated 4-20mA output, 26 million point data logger, and two programmable control relays. The sensor is classified as non-incendive for Class 1 Div 2 locations, and an intrinsically safe sensor is optional, for Class 1 Div 1 locations.

Upload: others

Post on 12-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TE T METE F - Greyline Instruments Inc. · 2020-06-02 · Installation is easy - without shutting down the flow system. No . contact is made with the moving fluid and no pipe cutting

THE RIGHT METER FORRaw SewageAerated WaterReturn & Waste SludgeSlurriesViscous LiquidsPulp StockAbrasives

GreylinePrecision Flow Measurement

An ONICON Brand

888-473-9546 greyline.com

DFM 6.1DOPPLER FLOW METER

Features• Fast, Non-Invasive Installation

• Simple 5-button Interface

• 26 million point Data Logger

• Hazardous Location CertifiedSensor

• Modbus® RTU or HART Optional

Accurate Flow Measurement of “Difficult” Fluids from Outside a PipeIdeal for “Difficult” Fluids Greyline Doppler Flow Meters monitor the flow rate of dirty or aerated liquids including: wastewater, sewage, slurries, abrasives, and viscous liquids. Recommended for full pipes and any fluid that contains solids or bubbles.

External Sensor No Contact, No MaintenanceThe DFM 6.1 clamp-on sensor is mounted on the outside of any pipe ½ inch / 12.7mm diameter or larger. To measure velocity an acoustic signal is reflected back to the sensor from moving particles or gas bubbles suspended in the fluid. Flow is calculated based on configured pipe ID.

Installation is easy - without shutting down the flow system. No contact is made with the moving fluid and no pipe cutting or drilling is required. There is no fouling or scale build-up on the sensor.

The DFM 6.1 Doppler Flow Meter includes an ultrasonic sensor, an easy to use 5-key configuration system, a large digital flow rate display with totalizer, isolated 4-20mA output, 26 million point data logger, and two programmable control relays. The sensor is classified as non-incendive for Class 1 Div 2 locations, and an intrinsically safe sensor is optional, for Class 1 Div 1 locations.

Page 2: TE T METE F - Greyline Instruments Inc. · 2020-06-02 · Installation is easy - without shutting down the flow system. No . contact is made with the moving fluid and no pipe cutting

888-473-9546

DFM 6.1DOPPLER FLOW METER

GreylinePrecision Flow Measurement

An ONICON Brand

Designed for “Difficult” LiquidsThe DFM 6.1 Doppler flow meter works best in applications that would defeat regular contacting flow meters. Because the sensor is mounted on the outside of the pipe, it is unaffected by abrasives or harsh fluids. There is no obstruction to flow and no pressure drop.

Enhanced Signal Processing and Industrial Noise Immunity for Reliable AccuracyThe DFM 6.1 Doppler flow algorithm filters out background noise and interference. The high speed digital signal processor discriminates against weak and distorted signals for increased reliability and accuracy.

Easy to InstallEach DFM 6.1 Doppler Flow Meter includes a clamp-on ultrasonic sensor, an adjustable stainless steel mounting clamp, and sensor coupling compound. The sensor fits on the outside of any pipe diameter ½” (12.7 mm) or larger. It takes just a few minutes to install. There is no need to shut down flow.

Simple, Single-Head Sensor designUltrasonic signals are transmitted and received from a single-head sensor. The mounting clamp (included) ensures correct sensor alignment on horizontal or vertical pipes. The DFM 6.1 automatically self-tunes to the cable length up to 500 ft.(152 m).

Works on most PipesThe Greyline DFM 6.1 Flow Meter measures flow in PVC, carbon steel, stainless steel, cast iron, HDPE, ductile iron, and concrete lined ductile iron... any pipe material that conducts ultrasound. Doppler signals cannot transmit through pipe walls which contain air pockets (e.g. concrete or wood), or loose pipe liners (with an air gap between the liner and pipe wall).

Backlit Display with Easy to Use, 5-key Menu SystemConfiguration is easy with the new DFM 6.1 user-friendly menu system. Press the arrow keys to scroll through menus, change settings, and enter calibration values. You can select English, French, or Spanish menus, enable a password to protect settings and control the brightness of the digital display.

Reverse Flow MeasurementThe DFM 6.1 measures flow in either direction and displays positive or negative values. You can control the totalizer to subtract reverse flow, or to totalize forward flow only. The 4mA setting can also be adjusted to a negative flow setting.

26 Million Point Data LoggerThe DFM 6.1 Doppler Flow Meter comes standard with a built-in 26 million point data logger. It includes Windows® software to display flow charts and tables and to create dynamic flow reports. Just plug in a standard USB flash drive and log files are downloaded automatically.

Principle of OperationThe DFM 6.1 sensor transmits continuous high-frequency sound through the pipe wall into the flowing liquid.Sound is reflected back to the sensor from particles or gas bubbles in the liquid. If the liquid is flowing, the reflected sound returns at an altered frequency (the Doppler effect). The DFM 6.1 continuously measures this frequency shift to accurately measure velocity.

SOUND WAVETRANSMITTEDFROM SENSORBUBBLES OR SOLIDS

REFLECT SOUND

SOUND WAVESREFLECTEDBACK TO SENSOR

SENSOR

Page 3: TE T METE F - Greyline Instruments Inc. · 2020-06-02 · Installation is easy - without shutting down the flow system. No . contact is made with the moving fluid and no pipe cutting

greyline.com

DFM 6.1DOPPLER FLOW METER

GreylinePrecision Flow Measurement

An ONICON Brand

GENERAL SPECIFICATIONS

Flow Rate Range

± 0.1 to 40 ft/sec (± 0.03 to 12.2 m/sec) in most applications

Pipe Size Any pipe ID from ½” to 180” (12.7 mm to 4.5 m)Accuracy ±2% of reading or 0.1 ft/sec (0.03 m/

sec) whichever is greater. Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%

Display White, backlit matrix - displays flow rate, relay states, 16-digit totalizer, operating mode, and calibration menu

Configuration Built-in 5-button keypad with English, French, or Spanish language selection

Power Input • 100-240VAC 50-60Hz, 10 VA maximum• Optional: 9-32VDC, 10 Watts maximum

Output Isolated 4-20mA (1000 ohm load max.) or 0-5VC (field selectable)

Control Relays Qty 2, rated 5 amp SPDT, programmable flow alarm, and/or proportional pulse

Data Logger Built-in 26 million point logger with USB output and Windows® software

Enclosure Watertight, dust tight NEMA4X (IP 66) polyester with a clear polycarbonate face

Electronics Operating Temperature

-10° to 140°F (-23° to 60°C)

Shipping Weight

14 lbs (6.3 kg)

Approvals CE, CSA/UL/EN 61010-1

Greyline DFM 6.1 Doppler Flow Meter SpecificationsSENSOR

Model SE4 Single-head ultrasonic with 25 ft (7.6 m) shielded cable and stainless steel mounting kit for pipes ½” (12.7 mm) ID or larger. Designed to withstand accidental submersion to 10 psi.Certified non-incendive for Class I Division 2, Groups A,B,C,D hazardous locations

Sensor Operating Temp.

-40° to 300°F (-40° to 150°C)

Exposed Materials

316SS

POPULAR OPTIONS

Sensors Intrinsic Safety Barriers for Sensor mounting in Class I, II, III, Div I, II, Groups C, D, E, F, G, hazardous locations

Industrial Automation Protocols

Modbus® RTU via RS-485 or HART (field selectable)

Sensor Cable 50 ft. (15 m) or 100 ft. (30 m) continuous shielded coaxial pair, or splice up to 500 ft (152 m) with junction box. Self tunes to extended cable.

Enclosure Heater

For outdoor installation, thermostatically controlled to -40°F (-40°C)

Control Relays 4 additional (6 total) rated 5 amp SPDT

APPLICATIONS

Recommended Liquids containing suspended solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm.

Pipe Materials Steel, stainless steel, cast iron, ductile iron, concrete lined ductile iron, PVC, HDPE, or any contiguous pipe material that conducts sound, including lined pipes with liner bonded to pipe wall. Avoid pipes with loose insertion liners and pipe walls which contain air.

Dimensions

SE4 ULTRASONICDOPPLER SENSOR

20 ft / 6 m3.375” / 85 mm1.375”35 mm

1.5”38 mm

ENDVIEW SIDE VIEW

SE4 ULTRASONICDOPPLER SENSOR

20 ft / 6 m3.375” / 85 mm1.375”35 mm

1.5”38 mm

ENDVIEW SIDE VIEW

10” /

254

mm

7.4” / 188 mm

PSL 5.0Pump StationLevel Controller

Conduit Entry Location

6.46” / 164 mm 5.12” / 130 mm

ENCLOSURE

10.9

4” /

278

mm

Side View

DFM 6.1DopplerFlow Meter

Page 4: TE T METE F - Greyline Instruments Inc. · 2020-06-02 · Installation is easy - without shutting down the flow system. No . contact is made with the moving fluid and no pipe cutting

DFM 6.1DOPPLER FLOW METER

Ideal for full pipes and any liquid containing gas bubbles or suspended solids.

Greyline DFM 6.1 Doppler Flow MeterThe DFM 6.1 flow sensor installs without cutting the pipe. It takes just a few minutes to mount on the outside of any pipe. Configuration is easy with the built-in, 5-button keypad. Select your choice of flow units and enter pipe diameter through the user-friendly calibration menu. Enable password protection to prevent tampering.

Special Features• Digital processing system tracks flow signals accurately• Noise suppression circuitry filters background noise and electrical interference

from industrial environments• Automatically converts between measurement units (e.g. gallons or liters)• Calibration data and totalizer values are stored automatically during power

interruptions• Output simulation function simplifies calibration of remote devices (e.g. chart

recorders or controllers)• Self-tunes to sensor cable length

Benefits of Non-Contacting Flow MeasurementNo Contact means no maintenance, no sensor fouling, no obstruction to flow, no pressure drop, no corrosion and no pipe cutting or drilling for installation.

How to OrderContact a Greyline sales representative in your area or phone one of our sales engineers. Describe your requirements and receive our prompt quotation.

Applications Support Take advantage of Greyline’s applications experience. Phone toll free 1-888-473-9546 for advice and information on applications, installation, or service for Greyline instruments.

No Risk Appraisal The Greyline DFM 6.1 Doppler Flow Meter must meet your requirements. Discuss your application with a Greyline representative to arrange a 30-day trial.

The Greyline Guarantee Quality of Materials and Workmanship - Each instrument manufactured by Greyline is warranted against defects in materials and workmanship for a period of one year from date of purchase. Refer to our limited warranty included with each product.

16456 Sixsmith Dr. • Long Sault, Ont. K0C 1P0 • Canada (P) 613-938-8956 / 888-473-9546 • (F) 613-938-4857 • www.greyline.com Rev 1.2

11451 Belcher Road South • Largo, FL 33773 • USA (P) 315-788-9500 / 888-473-9546 • (F) 315-764-419 • www.greyline.com

GreylinePrecision Flow Measurement

An ONICON Brand