Table 1GS
05/800GS
10/800GS
15/800GS
20/800GS
30/800
Nominal power 0,5kW 1kW 1,5kW 2kW 3kW
Output voltage 800V 800V 800V 800V 800V
Output current 0,9A 1,7A 3A 3,5A 5,3A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 0,6kVA 1,2kVA 1,8kVA 2,4kVA 3,6kVA
Fusing 6A 6A 6A (10A) 6A (10A) 10A
Cooling
Size
Weight 11kg 12kg
230V, +5/-10 %, 50/60Hz, (Option: 200V, L1, L2, PE)
3 x 400V, +5/-10%, 50/60Hz,(Option: 3 x 200V, only GS 15, GS 20), PE
GS 05 - GS 30
Current, voltage or power controlled
Forced air, maximum ambiente temperature 40° C
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
0 …100 % of nominal current, voltage or power
+/- 1 % of nominal value for current, voltage or power
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
3½- digit display for current, voltage and power
LpA < 70db (A)
ADL Technical Data Version 09-2009 2
Table 2GS
05/1000GS
10/1000GS
15/1000GS
20/1000GS
30/1000GS
12/2000
Nominal power 0,5kW 1kW 1,5kW 2kW 3kW 1,2kW
Output voltage 1000V 1000V 1000V 1000V 1000V 2000V
Output current 0,7A 1,4A 2,4A 2,8A 4,2A 1A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 0,6kVA 1,2kVA 1,8kVA 2,4kVA 3,6kVA 1,4kVA
Fusing 6A 6A 6A (10A) 6A (10A) 10A 6A
Cooling
Size
Weight 12kg11kg
3½- digit display for current, voltage and power
230V, +5/-10%, 50/60Hz, (Option: 200V, L1, L2, PE)
3 x 400V, +5/-10%, 50/60Hz,(Option: 3 x 200V, nur GS 15, GS 20), PE
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
LpA < 70db (A)
Forced air, maximum ambiente temperature 40° C
0 …100 % of nominal current, voltage or power
+/- 1 % of nominal value for current, voltage or power
Current, voltage or power controlled
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Quenching time: 6µs up to 3ms, automaticallyDelay Time: 6µs up ca. 10ms, automatically
ADL Technical Data Version 09-2009 3
Table 1GS
60/800GS
80/800GS
100/800GS
120/800GS
150/800
Nominal power 6kW 8kW 10kW 12kW 15kW
Output voltage 800V 800V 800V 800V 800V
Output current 10A 17A 17A 20A 25A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 6,6kVA 9kVA 11kVA 13,2kVA 16,5kVA
Fusing 16A 16A 20A 25A 25A
Cooling
Size
Weight 27kg 29kg 29kg 29kg 31kg
Mains cable 4 x 1,5mm² 4 x 1,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm²
3 x 1,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 4mm²
19“ slide-in, 3HU (132,5mm) 570mm deep
Output cableRG 213U or
+/- 1 % of nominal value for current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
3 x 400V, +5/-10%, 50/60Hz, PE
Forced air, maximum ambiente temperature 40° C
3½- digit display for current, voltage and power (Option)
LpA < 70db (A)
GS 60 - GS 150
Current, voltage or power controlled
0 …100 % of nominal current, voltage or power
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
ADL Technical Data Version 09-2009 4
Table 1GSW
100/500GSW
100/800GSW
150/400GSW
150/500GSW
150/600GSW
150/750
Nominal power 10kW 10kW 15kW 15kW 15kW 15kW
Output voltage 500V 800V 400V 500V 600V 750V
Output current 40A 20A 80A 60A 50A 38A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 11kVA 11kVA 16,5kVA 16,5kVA 16,5kVA 16,5kVA
Fusing 3 x 20A 3 x 20A 3 x 25A 3 x 25A 3 x 25A 3 x 25A
Cooling
Water connection
Cooling capability of water 500W 500W 680W 680W 680W 680W
Cooling capability of air 80W 80W 80W 80W 80W 80W
Size
Weight 42kg 42kg 44kg 44kg 44kg 44kg
Mains cable 4 x 2,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm² 4 x 4mm² 4 x 4mm²
Output cable 3 x 10mm² 3 x 2,5mm² 3 x 25mm² 3 x 16mm² 3 x 10mm² 3 x 10mm²
Mains connection (X2)
DC-connection (X1)
GSW 100 - GSW 300
0 …100 % of nominal current, voltage or power
19“ slide-in, 3HU x 700mm deep (without plug)
Harting Han k4/0
Harting Han 2 MOD
LpA < 70db (A)
3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
Current, voltage or power controlled
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
+/- 1 % of nominal value for current, voltage or power
Water, > 3 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
Swagelok B-QC 6 …
3½- digit display for current, voltage and power (Option)
ADL Technical Data Version 09-2009 5
Table 2GSW
150/800GSW
150/1000GSW
200/500GSW
200/750GSW
200/800GSW
200/900
Nominal power 15kW 15kW 20kW 20kW 20kW 20kW
Output voltage 800V 1000V 500V 750V 800V 900V
Output current 30A 25A 70A 50A 40A 40A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 16,5kVA 16,5kVA 22kVA 22kVA 22kVA 22kVA
Fusing 3 x 25A 3 x 25A 3 x 35A 3 x 35A 3 x 35A 3 x 35A
Cooling
Water connection
Cooling capability of water 680W 680W 950W 900W 900W 900W
Cooling capability of air 80W 80W 150W 100W 100W 100W
Size
Weight 44kg 44kg 49kg 49kg 49kg 49kg
Mains cable 4 x 4mm² 4 x 4mm² 4 x 6mm² 4 x 6mm² 4 x 6mm² 4 x 6mm²
Output cable 3 x 6mm² 3 x 4mm² 3 x 16mm² 3 x 10mm² 3 x 10mm² 3 x 10mm²
Mains connection (X2)
DC-connection (X1)
+/- 1 % of nominal value for current, voltage or power
3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
3½- digit display for current, voltage and power (Option)
LpA < 70db (A)
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
0 …100 % of nominal current, voltage or power
19“ slide-in, 3HU x 700mm deep (without plug)
Harting Han 2 MOD
Water, > 3 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
Swagelok B-QC 6 …
Current, voltage or power controlled
Harting Han k4/0
ADL Technical Data Version 09-2009 6
Table 3GSW
200/1000GSW
250/750GSW
250/800GSW
250/900GSW
300/500GSW
300/800
Nominal power 20kW 25kW 25kW 25kW 30kW 30kW
Output voltage 1000V 750V 800V 900V 500V 800V
Output current 35A 60A 50A 50A 70A 60A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 22kVA 28kVA 28kVA 28kVA 33kVA 33kVA
Fusing 3 x 35A 3 x 50A 3 x 50A 3 x 50A 3 x 63A 3 x 63A
Cooling
Water connection
Cooling capability of water 900W 1100W 1100W 1100W 1300W 1300W
Cooling capability of air 100W 110W 110W 110W 150W 150W
Size
Weight 49kg 51kg 51kg 51kg 53kg 53kg
Mains cable 4 x 6mm² 4 x 10mm² 4 x 10mm² 4 x 10mm² 4 x 10mm² 4 x 10mm²
Output cable 3 x 6mm² 3 x 16mm² 3 x 10mm² 3 x 10mm² 3 x 16mm² 3 x 16mm²
Mains connection (X2)
DC-connection (X1)
Harting Han k4/0
0 …100 % of nominal current, voltage or power
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)
Swagelok B-QC 6 …
19“ slide-in, 3HU x 700mm deep (without plug)
Harting Han 2 MOD
Current, voltage or power controlled
+/- 1 % of nominal value for current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
3½- digit display for current, voltage and power (Option)
Water, > 3 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
LpA < 70db (A)
ADL Technical Data Version 09-2009 7
Table 4GSW
300/1000
Nominal power 30kW
Output voltage 1000V
Output current 50A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 33kVA
Fusing 3 x 63A
Cooling
Water connection
Cooling capability of water 1300W
Cooling capability of air 150W
Size
Weight 53kg
Mains cable 4 x 10mm²
Output cable 3 x 10mm²
Mains connection (X2)
DC-connection (X1)
Harting Han k4/0
Harting Han 2 MOD
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)
Water, > 3 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
Swagelok B-QC 6 …
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
0 …100 % of nominal current, voltage or power
+/- 1 % of nominal value for current, voltage or power
19“ slide-in, 3HU x 700mm deep (without plug)
Current, voltage or power controlled
3½- digit display for current, voltage and power (Option)
LpA < 70db (A)
ADL Technical Data Version 09-2009 8
Table 1GX
50/800GX
60/800GX
80/800GX
80/1000GX
100/400GX
100/600
Nominal power 5kW 6kW 8kW 8kW 10kW 10kW
Output voltage 800V 800V 800V 1000V 400V 600V
Output current 14A 15A 20A 16A 38A 30A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 6kVA 6,6kVA 9kVA 9kVA 11kVA 11kVA
Fusing 3 x 16A 3 x 16A 3 x 20A 3 x 20A 3 x 20A 3 x 20A
Cooling
Water connection
Cooling capability of water 300W 300W 400W 400W 500W 500W
Cooling capability of air 45W 45W 50W 50W 50W 50W
Size
Weight 21kg 21kg 23kg 23kg 23kg 23kg
Mains cable 4 x 1,5mm² 4 x 1,5mm² 4 x 2,5mm² 4 x 2,5mm² 4 x 2,5mm² 4 x 2,5mm²
Output cable 3 x 1,5mm² 3 x 1,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 6mm² 3 x 6mm²
Mains connection (X2)
DC-connection (X1)
LpA < 70db (A)
3 x 400V, +/-10%, 50/60Hz
½ 19“ slide-in, 3HU (130mm) 520mm deep (without plug), 590mm (with plug).
Swagelok B-QC 6 …
0 …100 % of nominal current, voltage or power
+/- 1 % of nominal value for current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
3½- digit display for current, voltage and power (Option)
GX 60 - GX 150
Current, voltage or power controlled
Harting Han-Modular Compact
Water, > 1,5 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
Harting Han-Modular Compact
ADL Technical Data Version 09-2009 9
Table 2GX
100/800GX
100/1000GX
120/800GX
150/800GX
150/1000
Nominal power 10kW 10kW 12kW 15kW 15kW
Output voltage 800V 1000V 800V 800V 1000V
Output current 25A 20A 30A 38A 30A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 11kVA 11kVA 13,2kVA 16,5kVA 16,5kVA
Fusing 3 x 20A 3 x 20A 3,25A 3 x 25A 3 x 25A
Cooling
Water connection
Cooling capability of water 500W 500W 600W 750W 750W
Cooling capability of air 50W 50W 60W 60W 60W
Size
Weight 23kg 23kg 23kg 25kg 25kg
Mains cable 4 x 2,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm² 4 x 4mm²
Output cable 3 x 4mm² 3 x 4mm² 3 x 6mm² 3 x 6mm² 3 x 6mm²
Mains connection (X2)
DC-connection (X1)
Swagelok B-QC 6 …
3½- digit display for current, voltage and power (Option)
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
LpA < 70db (A)
3 x 400V, +/-10%, 50/60Hz
Harting Han-Modular Compact
Harting Han-Modular Compact
+/- 1 % of nominal value for current, voltage or power
Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus
½ 19“ slide-in, 3HU (130mm) 520mm deep (without plug), 590mm (with plug).
Water, > 1,5 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
0 …100 % of nominal current, voltage or power
Current, voltage or power controlled
ADL Technical Data Version 09-2009 10
Table 1HX
150/400HX
150/500HX
150/600HX
150/800HX
150/1000HX
200/500
Nominal power 15kW 15kW 15kW 15kW 15kW 20kW
Output voltage 400V 500V 600V 800V 1000V 500V
Output current 80A 60A 50A 30A 25A 70A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 16,5kVA 16,5kVA 16,5kVA 16,5kVA 16,5kVA 22kVA
Fusing 3 x 25A 3 x 25A 3 x 25A 3 x 25A 3 x 25A 3 x 35A
Cooling
Water connection
Cooling capability of water 680W 680W 680W 680W 680W 950W
Cooling capability of air 80W 80W 80W 80W 80W 150W
Size
Weight 35kg 35kg 35kg 32kg 32kg 37kg
Mains cable 4 x 4mm² 4 x 4mm² 4 x 4mm² 4 x 4 mm² 4 x 4mm² 4 x 6mm²
Output cable 3 x 25mm² 3 x 16mm² 3 x 10mm² 3 x 6mm² 3 x 4mm² 3 x 16mm²
Mains connection (X2)
DC-connection (X1)
SMC KQ2 10mm(Option: Swagelok B QC-6)
Width: 218mm, Hight: 222mm, Length (without plug): 645mm
Harting Han 2 MOD
Harting Han k4/0
LpA < 70db (A)
3 x 400V, +/-10 %, 50/60Hz(Option: 3 x 440V or 3 x 480V)
Water, > 3 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
+/- 1 % of nominal value for current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
3½- digit display for current, voltage and power (Option)
HX 150 - HX 300
External via A/D interface AS 4, AS 4 F or Profibus
0 …100 % of nominal current, voltage or power
Current, voltage or power controlled
ADL Technical Data Version 09-2009 11
Table 2HX
200/800HX
200/1000HX
250/800HX
250/1000HX
300/800HX
300/1000
Nominal power 20kW 20kW 25kW 25kW 30kW 30kW
Output voltage 800V 1000V 800V 1000V 800V 1000V
Output current 40A 35A 50A 40A 60A 50A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
Power consumption 22kVA 22kVA 28kVA 28kVA 33kVA 33kVA
Fusing 3 x 35A 3 x 35A 3 x 50A 3 x 50A 3 x 63A 3 x 63A
Cooling
Water connection
Cooling capability of water 900W 900W 1100W 1100W 1300W 1300W
Cooling capability of air 100W 100W 110W 110W 150W 150W
Size
Weight 37kg 37kg 39kg 39kg 41kg 41kg
Mains cable 4 x 6mm² 4 x 6mm² 4 x 10mm² 4 x 10mm² 4 x 10mm² 4 x 10mm²
Output cable 3 x 10mm² 3 x 6mm² 3 x 10mm² 3 x 10mm² 3 x 16mm² 3 x 10mm²
Mains connection (X2)
DC-connection (X1)
Width: 218mm, Hight: 222mm, Length (without plug): 645mm
Harting Han k4/0
Harting Han 2 MOD
LpA < 70db (A)
3 x 400V, +/-10 %, 50/60Hz(Option: 3 x 440V or 3 x 480V)
Water, > 3 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
SMC KQ2 10mm(Option: Swagelok B QC-6)
0 …100 % of nominal current, voltage or power
+/- 1 % of nominal value for current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
3½- digit display for current, voltage and power (Option)
Current, voltage or power controlled
External via A/D interface AS 4, AS 4 F or Profibus
ADL Technical Data Version 09-2009 12
Table 1GP
10/800GP
15/800GP
20/800GP
30/800GP
30/1000
Nominal power 1kW 1,5kW 2kW 3kW 3kW
Output voltage 800V 800V 800V 800V 1000V
Output current 1,7A 3A 3,5A 5,3A 4,2A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Indications
Noise emission
Mains connection
230V, +5/-10%, 50/60Hz, (Option:
200V, L1, L2, PE)
Power consumption 1,2kVA 1,8kVA 2,4kVA 3,6kVA 3,6kVA
Fusing 6A 6A (10A) 6A (10A) 10A 10A
Cooling
Seize
Weight 11kg
3 x 400V, +5/-10%, 50/60Hz,(Option: 3 x 200V, nur GP 15, GP 20), PE
Forced air, maximum ambiente temperature 40° C
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
12kg
+/- 1 % of nominal value for current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
Power Supplies for Melec-Pulse Generator
Current, voltage or power controlled
External via A/D interface AS 6
0 …100 % of nominal current, voltage or power
3½- digit display for current, voltage and power
LpA < 70db (A)
ADL Technical Data Version 09-2009 13
Table 2GP
60/800GP
100/800GP
120/800GP
150/800
Nominal power 6kW 10kW 12kW 15kW
Output current 800V 800V 800V 800V
Output voltage 10A 17A 20A 25A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Noise emission
Mains connection
Power consumption 6,6kVA 11kVA 13,2kVA 16,5kVA
Fusing 16A 20A 25A 25A
Cooling
Seize
Weight 27kg 29kg 29kg 31kg
Mains cable 4 x 1,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm²
3 x 1,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 4mm²
+/- 1 % of nominal value for current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
Output cable
3½- digit display for current, voltage and power
3 x 400V, +/-10%, 50/60Hz, PE
Forced air, maximum ambiente temperature 40° C
½ 19“ slide-in, 3HU (132,5mm), 560mm deep
RG 213U or
Current, voltage or power controlled
External via A/D interface AS 6
0 …100 % of nominal current, voltage or power
ADL Technical Data Version 09-2009 14
Table 3GPW
150/800GPW
200/800GPW
250/800GPW
300/800GPW
300/1000
Nominal power 15kW 20kW 25kW 30kW 30kW
Output voltage 800V 800V 800V 800V 1000V
Output current 30A 40A 50A 60A 50A
Control
Modes of operation
Set point
Output accuracy
Arc suppression
Noise emission
Mains connection
Power consumption 16,5kVA 22kVA 28kVA 33kVA 33kVA
Fusing 3 x 25A 3 x 35A 3 x 50A 3 x 63A 3 x 63A
Cooling
Water connection
Cooling capability of water 680W 900W 1100W 1300W 1300W
Cooling capability of air 80W 100W 110W 150W 150W
Seize
Weight 44kg 49kg 51kg 53kg 53kg
Mains cable 4 x 4mm² 4 x 6mm² 4 x 10mm² 4 x 10mm² 4 x 10mm²
Output cable 3 x 6mm² 3 x 10mm² 3 x 10mm² 3 x 16mm² 3 x 10mm²
Mains connection (X2)
DC-Connection (X1)
Harting Han k4/0
Harting Han 2 MOD
+/- 1 % of nominal value for current, voltage or power
Swagelok B-QC 6 …
External via A/D interface AS 6
Current, voltage or power controlled
19“ slide-in, 3HU x 700mm deep (without plug)
3½- digit display for current, voltage and power
3 x 400V, +/-10%, 50/60Hz
0 …100 % of nominal current, voltage or power
Quenching time: 6µs up to 3ms, automaticallyDelay time: 6µs up ca. 10ms, automatically
Water, > 3 L/Min, 2 to 8 Bar, < 40° CForced air, maximum ambiente temperature 40° C
ADL Technical Data Version 09-2009 15
Table 1
Nominal voltage
Nominal power
Pulse frequency
Pulse on time
Pulse off time
Principle of operation
Maximum cable length
Indications
Auxiliary voltage
Cooling
Seize
Weight
Compatible with the following power supplies:
Forced air, maximum ambiente temperature 40° C
157mm width, 118mm height, 430mm length
8 kg
Power supplies of the series GS and GSW with a maximum nominal power of 30kW
ADL-Pulse Generator RD 300
24V DC +/- 10%, 0,6A
ZVS (Zero Voltage Switch) Resonance converter
30kW (DC Output power of power supply)
2kHz, fixed
480µS bis 490µS
10µS bis 20µS
RD 300
5m (between Pulse Generator and Cathode)
Status LEDs
800V (DC Output voltage of power supply)
ADL Technical Data Version 09-2009 16
Table 1 GG 03 GG 03.1 GG 12 GG 12.1
Nominal power 300W 30W 1,2kW 200W
Output voltageNegative,
max. 1000VNegative,
max. 1000VPositive, max.
2000VPositive, max.
2000V
Output current 300mA 30mA 1A 100mA
Control
Modes of operation
Set point
Indications
Noise emission
500VA 100VA 1500VA 250VA
Cooling
Seize
Weight
Forced air, maximum ambiente temperature 40° C
½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)
11kg
3 ½ digit displays for voltage and current
LpA < 70 db(A)
Mains connections230V, +5/-10%, 50/60Hz, PE
Accelerator and Beam GG 03, GG 03.1, GG 12, GG 12.1
Voltage or current controlled
Manual via frontpanel or external via A/D Interface AS 4 or Profibus
0 ...100 % of nominal voltage or current
ADL Technical Data Version 09-2009 17
Table 1Cathode
GIP 10Discharge Emission
Nominal power 990W 25W 25W 990W 2,5W
Output voltage 33V 25V 25V 33V 25V
Output current 30A 1A 1A 30A 0,1A
Control
Modes of operation
Set point
Indications
Noise emission
Mains connection
Cooling
Seize
Weight
½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)
11kg
3 ½ digit displays for emission and filament current
LpA < 70db(A)
230V, +5/-10%, 50/60Hz, PE , 1200VA
Forced air, maximum ambiente temperature 40° C
GIP 10.1Cathode Emission
Emission or filament current controlled
Manual via frontpanel or external via A/D Interface AS 4 or Profibus
0 ...100 % of nominal emission or filament current
Neutralizer GIP 10 and GIP 10.1
ADL Technical Data Version 09-2009 18
Table 1
Nominal power
Output voltage
Output current
Control
Modes of operation
Set point
Indications
Noise emission
Mains connection
Cooling
Seize
Weight
230V, +5/-10%, 50/60Hz, PE, 1200VA
Forced air, maximum ambiente temperature 40° C
½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)
11kg
Manual via frontpanel or external via A/D Interface AS 4 or Profibus
0 ...100 % of nominal voltage or current
3 ½ digit displays for voltage and current
LpA < 70db(A)
900W
150V, floating up to 2kV
6A
Voltage or current controlled.
Discharge GDIGDI 09
ADL Technical Data Version 09-2009 19
Table 1
Nominal power
Output voltage
Output current
Control
Modes of operation
Set point
Indications
Noise emission
Mains connection
Cooling
Seize
Weight
½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)
11kg
3 ½ digit displays for voltage and current
LpA < 70db(A)
230V, +5/-10%, 50/60Hz, PE, 1200VA
Forced air, maximum ambiente temperature 40° C
30A
Voltage or current controlled
Manual via frontpanel or external via A/D Interface AS 4 or Profibus
0 ...100 % of nominal voltage or current
CathodeGC 10
1kW
35V, floating up to 2kV
ADL Technical Data Version 09-2009 20
Table 1
Nominal power
Output voltage
Output current
Control
Modes of operation
Set point
Indications
Noise emission
Mains connection
Cooling
Seize
Weight
230V, +5/-10%, 50/60Hz, PE, 1200VA
Forced air, maximum ambiente temperature 40° C
½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)
11kg
Manual via frontpanel or external via A/D Interface AS 4 or Profibus
0 ...100 % of nominal voltage or current
3 ½ digit displays for voltage and current
LpA < 70db(A)
960W
160V, floating
6A
Voltage or current controlled
Magnet GM 10GM 10
ADL Technical Data Version 09-2009 21
Table 1GD
20/400GD
20/600GD
20/800GD
30/400GD
30/600GD
30/800
Nominal power 2kW 2kW 2kW 3kW 3kW 3kW
Output voltage 400V 600V 800V 400V 600V 800V
Output current 7A 4,5A 3,5A 10A 6,5A 5,3A
Control
Modes of operation
Set point
Indications
Noise emission
Mains connection
Cooling
Seize
Weight
½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)
11kg
3 ½ digit displays for voltage and current
LpA < 70 db(A)
3 x 400V, +5/-10%, 50/60Hz, PE(Option: 3 x 200V, only GD 20)
Forced air, maximum ambiente temperature 40° C
Plasma Sources
Voltage or current controlled
Manual via front panel or external via A/D interface AS 4 or Profibus
0 ...100 % of nominal voltage or current
ADL Technical Data Version 09-2009 22
HV-Diode, Table 1
Nominal voltage
Nominal current
Forward Voltage
Connection
Maximum cable length
Housing
Protection
Weight
Compatible with the following power supplies:
Power Supplies of the series GS, GSW and GX with a maximum nominal voltage of 30kW
3 m
Aluminum B 125 mm x L 127 m x H 60 mm
IP 56
ca. 0,9 kg (without cable)
1000V DC Output voltage of power supply)
70A DC (Output cuurent of power supply)
3,5V
Coaxial cable RG 213 U, PE
D300 Cathode Clamp DiodeD300
ADL Technical Data Version 09-2009 23
Table 1
Interface compatibility
Control connection
Operation voltage
Indication
Modes of operation
Control
Set value setting
Seize
Weight
Switchable: Current, power or voltage control
Potentiometer with 10-turn-dial mechanism
280mm x 140mm x 110mm
Ca. 0,7kg (without cable)
25-pol. Sub.-D
24V DC, internal voltage suppy via interface
3½-digit LCD, switchable to actual value power, actual value current and actual value voltage, set point, reference voltage
Switchable: Operation via remote control or via front panel
Remote ControlRC 4
AS 3, AS 4, AS 4F (with Adapter)-cable
ADL Technical Data Version 09-2009 24
ADL Technical Data Version 09-2009 25
ADL Technical Data Version 09-2009 26
ADL Technical Data Version 09-2009 27
ADL Technical Data Version 09-2009 28
ADL Technical Data Version 09-2009 29
ADL Technical Data Version 09-2009 30
ADL Technical Data Version 09-2009 31
ADL Technical Data Version 09-2009 32
ADL Technical Data Version 09-2009 33
ADL Technical Data Version 09-2009 34
ADL Technical Data Version 09-2009 35
ADL Technical Data Version 09-2009 36
ADL Technical Data Version 09-2009 37
ADL Technical Data Version 09-2009 38
ADL Technical Data Version 09-2009 39
ADL Technical Data Version 09-2009 40
ADL Technical Data Version 09-2009 41
ADL Technical Data Version 09-2009 42
ADL Technical Data Version 09-2009 43
ADL Technical Data Version 09-2009 44
ADL Technical Data Version 09-2009 45
ADL Technical Data Version 09-2009 46
ADL Technical Data Version 09-2009 47
ADL Technical Data Version 09-2009 48