VITOCELL-B 300Dual coil domestic hot water storage tank
79 and 120 USG / 300 and 450 ltr capacity
Technical Data ManualModel Nos. and pricing: see Price List
This tank version is not suitablefor steam heating applications.
Vitocell-B 300
EVB Series
Vertical indirect-fired domestic hot water storage tankof high-grade stainless steel with two coils
One heat exchanger coil facilitates heat transfer from the solarcollectors to domestic hot water, a second heat exchanger coilallows reheating of the water content by the hot water heatingboiler.
5167 415 v3.0 03/2008
Product Information
2 VITOCELL-B 300
Product Information
Domestic hot water storage tank ofhigh-grade stainless steel highly effectiveall-around thermal insulation.Fully hygienic, efficient and economicaldomestic hot water production by solarcollectors and a hot water heating boiler.Heat from the solar collectors is transferredto the domestic hot water via the lowertank coil.
Benefits at a glance:
H Corrosion-resistant tank of high-grade SA240-316 Ti stainless steel offers a longservice life.
H Fully hygienic due to high qualityhomogeneous stainless steel surfaces.
H The high-alloy material is immune tocracking or peeling. The tank stayshygienic and requires only minimumservice.
H Does not require a consumable anode forcorrosion protection.
H The entire water content is heated by a1¼”/25 mm diameter stainless steel heatexchanger surface which extends to thebottom of the tank.
H Large heat exchanger surfaces allow fastand even heating of the entire watercontent, guaranteeing a high level ofdomestic hot water comfort.
H Standby losses minimized by highlyeffective HCFC-free insulation.79 USG / 300 ltr version comes equippedwith hard PUR foam.120 USG / 450 ltr version is supplied withremovable soft PUR foam insulation foreasier handling.
H Two thermometers to show the DHWtemperature at the top of the tank, and atthe midpoint of the tank.
H Tank design is accepted in the State ofMassachusetts as being ASME equivalent.
5167415v3
.0
Product InformationCross-Section
Product may not be exactly as illustrated.
VITOCELL-B 300 3
Inspection port /clean-out opening
Two thermometers
Stainless steel domestichot water storage tank
Upper coil-domestic hot water is reheated byhot water heating boiler
PUR Foam insulation (HCFC-free, 79 USG / 300 ltr)Soft polyurethane foam (120 USG / 450 ltr)
Lower coil-connection for solar connectors
Inspection port /clean-out opening
Domestic hot water connection / drain
5167415v3
.0
Technical Data
4 VITOCELL-B 300
Technical Data
For DHW production in conjunction with solar systems Suitable for heating systems with:and heating boilers, and heating systems without H max. working pressure on heat exchanger side up to 220 psig atlow limit for dual coil operation 392°F/200°C
H max. working pressure on DHW water side of up to 150 psig at210°F/99°C
H max. testing pressure on DHW side of 300 psig
Storage capacity USG / ltr 79 / 300 120 / 450
Coil upper*1 lower*2 upper*1 lower*2
Recovery rate*3
with a DHW temperature increase from 50 to 113 ºF/194ºF/90ºC
MBH / kWGPH / ltr/h
273 / 80519 / 1965
318 / 93604 / 2285
273 / 80519 / 1965
328 / 96623 / 2358p
10 to 45 ºC and a supply water temperature of . . . . . .
176ºF/80ºCMBH / kWGPH / ltr/h
219 / 64415 / 1572
246 / 72467 / 1769
218 / 64415 / 1572
219 / 73474 / 1793
158ºF/70ºCMBH / kWGPH / ltr/h
154 / 45292 / 1106
178 / 52337 /1277
154 / 45292 / 1106
191 / 56364 / 1376
140ºF/60ºCMBH / kWGPH / ltr/h
96 / 28182 / 688
102 / 30195 / 737
96 / 28182 / 688
126 / 37240 / 909
122ºF/50ºCMBH / kWGPH / ltr/h
51 / 1597 / 368
51 / 2197 / 368
51 / 1597 / 368
61 / 18117 / 442
Recovery rate*3
with a DHW temperature increase from 50 to 140 ºF/ 194ºF/90ºCMBH / kWGPH / ltr/h
253 / 74336 / 1273
278 / 82372 / 1410
253 / 74336 / 1273
276 / 81368 / 1393p
10 to 60 ºC and a supply water temperature of......176ºF/80ºC
MBH / kWGPH / ltr/h
184 / 54245 / 929
202 / 59268 / 1014
184 / 54245 / 929
212 / 62282 / 1066
158ºF/70ºCMBH / kWGPH / ltr/h
120 / 35159 / 602
140 / 41186 / 705
120 / 35159 / 602
147 / 43195 / 739
Insulation PUR Foam Soft polyurethane foam
Standby losses*4 MBH/24h 7.2 9.2
Overall dimensions with insulation*5
Overall length (∅)
Overall width
Overall height
Tilt height including insulation
inchesmminchesmminchesmminchesmm
2563328
70470
177972
1821
36.392338.497468.5174065.61690
WeightTank with insulation
lbskg
251114
275125
Heat exchanger coil USGltr
2.911
2.911
2.911
3.915
Heat exchanger area ft.2
m216.11.5
16.11.5
15.61.45
20.51.9
Connections CoilsDomestic cold/hot waterRecirculation
∅” (male thread)∅” (male thread)∅” (male thread)
1”1”1”
1¼”1¼”1¼”
*1 The upper coil is designated for connection to a hot water heating boiler or a heat pump.*2 The lower coil is designated for connection to solar collector panels or heat pumps.*3 When planning for the recovery rate as stated or calculated, allow for the corresponding circulation pump.
The stated recovery rate is only achieved when the rated output of the boiler is equal to or greater than that stated under “Recoveryrate”.
*4 Measured values are based on a room temperature of 68°F / 20 ºC and a domestic hot water temperature of 149°F / 65 ºC and can varyby 5%.
*5 For other dimensions, see illustrations and tables on pages 5 and 6.
" For information regarding other Viessmann System Technology componentry, please reference documentation of the respective product.
5167415v3
.0
Technical Data
LegendIO Inspection and clean-out openingD DrainBWR Boiler water return (upper coil)SCR Solar collector return (lower coil) or
boiler returnBWS Boiler water supply (upper coil)SCS Solar collector supply (lower coil) or
boiler supplyDCW Domestic cold waterSW1 Sensor well opening for DHW
tank temperature sensor or boilercontroler aquastat (located at thesame height as BWS (79 USG /300 ltr only), rotated 20º)
SW2 Sensor well for lower thermometerat SCS level
DHW Domestic hot waterRT Recirculation tappingTPV Temperature and pressure relief
valve
*1For solar heating systems Viessmannrecommends placement of the DHW tanktemperature sensor in the solar collectorreturn (SCR). This requires a brass elbowwith sensor well (accessory - Part No.7175 213).The DHW tank temperature sensor of theboiler control is placed in SW1.
BWS
k
IO
b
a
c
de
f
gOve
rallhe
ight
h
DHW
RT
BWR
SCS
SCR
DCW/D
*1
YTPV
79 USG / 300 ltr Tank
Ove
rallwidth
Overall depth
m
n
SW1
SW2
*1
Technical Data
VITOCELL-B 300 5
DHW tank temperature sensorin solar heating applications79 USG / 300 ltr
DHW tank temperature sensor for solarapplication (included with solarcontrol unit)Brass elbow with sensor wellSolar collector return connection
Dimensions
Storagecapacity
USG /ltr
79 /300
a
b
c
d
e
f
g
h
k
m
n
inchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmm
3½87
11¾301292/375137½951431/31101
541369642/31640
14357
410029½75154
1369
5167415v3
.0
5167415v3
.0
Technical Data
SCSBWRRT
g
a
ed
cb
kh
IO
DHW
DCW/D
f Ove
rallhe
ight
BWS
SCR*1
120 USG / 450 ltr Tank LegendIO Inspection and clean-out openingD DrainBWR Boiler water return (upper coil)SCR Solar collector return (lower coil) or
boiler returnBWS Boiler water supply (upper coil)SCS Solar collector supply (lower coil) or
boiler supplyDCW Domestic cold waterSW1 Sensor well opening for DHW
tank temperature sensor or boilercontroler aquastat
SW2 Sensor well for lower thermometerat SCS level
DHW Domestic hot waterRT Recirculation tappingTPV Temperature and pressure relief
valve
*1For solar heating systems Viessmannrecommends placement of the DHW tanktemperature sensor in the solar collectorreturn (SCR). This requires a brass elbowwith sensor well (accessory - Part No.7219 729).The DHW tank temperature sensor ofthe boiler control is placed in SW1.
Ove
rallwidth
Overall depth
n
m
SW2*1
SW1
C
Technical Data
6 VITOCELL-B 300
DHW tank temperature sensorin solar heating applications120 USG / 450 ltr
DHW tank temperature sensor for solarapplication (included with solarcontrol unit)Brass elbow with sensor wellSolar collector return connection
Dimensions
Storagecapacity
USG /ltr
120 /450
a
b
c
d
e
f
g
h
k
m
n
inchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmminchesmm
41/16103
177/845331½80236
912397/81012477/81216
631601
20508
410031½80246
1170
5167415v3
.0
5167415v3
.0
Technical Data
VITOCELL-B 300 7
Pressure drop on heating water side Domestic hot water pressure dropof a single coil
Lower indirect coil, 120 USG / 450 ltr capacityLower indirect coil, 79 USG / 300 ltr capacityUpper indirect coil, 79 USG / 300 ltr and 120 USG / 450 ltr capacity
5167415v3
.0
Waterflow
16
2024
3240
80
120
160
200
1.6
2
2.4
3.2
4
8
12
240
320400
1.2Pres
sure
drop
2.2
500
2.6
600
3.5
800
4.4
1000
92000
13
3000
18
4000
22
5000
26
6000
31
7000
ltr/h
GPM44
10000
“w.c.
mba
r
C
Waterflow
8 20
0.8 2
1.2 3
1.6 4
2 5
2.4 6
3.2 8
4 10
0.4 1
40 100
32 80
24 60
20 50
16 40
12 30
Pres
sure
drop
2.2
500
3.5
800
4.4
1000
92000
13
3000
18
4000
22
5000
26
6000
“w.c.
mba
r
ltr/h
GPM2.6
600
Standard Equipment/Product Installation
Y
8 VITOCELL-B 300
Standard Equipment
79 USG / 300 ltr capacity DHW TankDHW tank made from high-alloy stainlesssteel with fitted PUR hard foam thermalinsulation.– 2 thermometers °F / °C– adjustable leveling bolts
The following are packed separately andattached to the crate:– 1 Loctite package– 1 temperature and pressure relief valve– 2 reduction couplings (1”x½”)– 2 sensor wells– 2 insulation blankets for sensor wells– 7 brass adaptors (1”)– 1 brass tee (1”)– 1 brass hex bushing (1”x¾”)– 1 brass cap (1”)
Must be ordered separately:– 1 brass elbow with sensor well for solarcollector return, Part No. 7175 213
Product Installation
Domestic hot water connection
120 USG / 450 ltr capacity DHW TankDHW tank made from high alloy stainlesssteel and separately packed soft PURfoam thermal insulation.– 2 thermometers °F / °C– adjustable leveling bolts
The following are packed separately andattached to the crate:– 1 Loctite package– 1 temperature and pressure relief valve– 2 reduction couplings (1”x½”)– 2 sensor wells– 2 insulation blankets for sensor wells– 7 brass adaptors (1¼”)– 1 brass tee (1¼”)– 1 brass hex bushing (1¼”x¾”)– 1 brass cap (1¼”)
Must be ordered sepatarely:– 1 brass elbow with sensor well for solarcollector return, Part No. 7219 729
Domestic hot water supplyDHW recirculation lineDHW recirculation pumpSpring-loaded flow check valveDischarge pipePressure and temperature relief valveShut-off valveDrainDomestic cold water supply linesBackflow preventerDomestic cold water inletPrecharged expansion tank(required where backflow preventer isinstalled; check local plumbing codesand requirements)Thermostatic mixing valve/anti-scaldvalve for solar applications
5167415v3
.0
5167415v3
.0
Due to the potentially high DHWtemperatures generated by the solarheating system, the domestic hotwater temperature must be limited to amaximum of 140°F/60°C by installinga mixing device, e.g. a thermostaticmixing valve. The mixing device doesnot completely eliminate the risk ofscalding at the tap. The installation of amixing tap is required.
WARNING
System Design Guidelines
VITOCELL-B 300 9
Installation Example
Solar collectorCollector temperature sensorAir vent valve*1
Solar Divicon (pumping station)Solar collector supplySolar collector returnFill manifold *2
Solar hand pumpDomestic cold waterDHW tank temperature sensor (solar)Vitocell-B 300Air separatorDHW tank temperature sensor (boiler)
P Oil-/Gas-fired boiler
R Heating circuitS TapsT Recirculation pumpU Domestic hot waterV Solar control unitT Temperature sensor
*1 Install at least one air vent valve (fast air vent valve with shutoff valve or manual vent valve) at highest point of system.*2 Integrated in Solar Divicon DN20 and DN25 models.
5167415v3
.0
T T
T
T
Y
P
R
V
T
SU
T
System Design Guidelines
24
Ø19Ø17
10 VITOCELL-B 300
Sensor well
The supplied stainless steel sensor wells areto be used for control sensors to ensuremaximum operational safety. The top sensorwell is used for the DHW sensor connectedto the boiler control.Should the supplied sensors not fit into thesensor wells, other stainless steel sensorwells must be used.For solar heating systems, Viessmannrecommends placement of the DHW tanktemperature sensor in the solar collectorreturn. This requires a brass elbow withsensor well included in the accessory pack(see pg. 8).
Dimensionscapacity
USG /ltr
79 /300
120 /450
a
b
inchesmminchesmm
8.72207.9200
1333012¼310
Heating water supply temperatureover 230ºF / 110ºC
These operating conditions require theinstallation of an additional safety high limitinto the DHW storage tank, preventing thetemperature from rising above 203ºF /95ºC. A domestic hot water temperingvalve must be used.
Temperature and pressurerelief valve
A temperature and pressure relief valve(T&P relief valve) is supplied with the tank.The heating contractor must install thevalve on each tank in a method meetingcode requirements. If local codes require adifferent relief valve, substitute themanufacturer’s supplied valve. The tank isapproved for 100 psig where a CRN isrequired. Maximum operating pressure is150 psig.The T&P relief valve supplied with the tankis manufactured by Watts Industries (Model40XL-8), set to 100 psig for Canadianinstallations and set to 150 psig for USinstallations (where applicable). The valve isASME pressure steam rated for 998 MBHand CSA temperature steam rated for200 MBH. It is tested under ANSI Z21.22Code for Relief Valves and Automatic GasShut-off Devices for Hot Water SupplySystems. The relief temperature is set at210°F / 99°C. The valve has a malethreaded inlet and female threaded outlet,both ¾” sizes.
Backflow preventers
Where backflow preventers are required, adomestic water expansion tank installationis recommended in the cold water inletpiping before the cold water enters theVitocell. For the backflow device, observelocal plumbing codes and regulations.
Warranty excerpt
Our warranty for domestic hot water tanksstates that the water to be heated must beof drinking (potable) water quality and thatany water treatment equipment in use mustfunction correctly.Viessmann accepts no responsibility fordamage howsoever caused and reserves theright to withdraw the product warranty if theproduct has been improperly installed ormisapplied by the installer, contractor or finaluser. In order to qualify for product warranty,strict adherence to the installation andservice manuals must be assured. In theevent that Viessmann non-approvedcomponents are utilized, Viessmann reservesthe right to withdraw all expressed or impliedwarranties without written notice.
The water to be heated with the Vitocellmust be drinking (potable) water quality. Ifthe tank is used to heat other media, thewarranty will be null and void. Damageresulting from excessive pressure ortemperature is clearly not the responsibilityof Viessmann.
The amount of chloride and sulfateacceptable to the tank is limited. In areaswhere high concentrations of chloride andsulfate are present in drinking water, pleaseconsult Viessmann for directions.
For full warranty details, please read theproduct warranty card.
5167415v3
.0
To ensure optimum, safe operation, thesupplied stainless steel well must beinstalled. The well diameter is largeenough to accommodate a wide varietyof sensing bulbs.Always use spring clip to ensure propercontact of capillary bulb against thestainless steel well for propersensing/heat transfer!
WARNING
VITOCELL-B 300 11
5167415v3
.0
Viessmann Manufacturing Company Inc.750 McMurray RoadWaterloo, Ontario • N2V 2G5 • CanadaTel. (519) 885-6300 • Fax (519) 885-0887www.viessmann.ca • [email protected]
Viessmann Manufacturing Company (U.S.) Inc.45 Access RoadWarwick, Rhode Island • 02886 • USATel. (401) 732-0667 • Fax (401) 732-0590www.viessmann-us.com • [email protected]
12 VITOCELL-B 300
Tec
hnical
inform
ationsu
bjec
tto
chan
gewitho
utno
tice
.Printedon
environm
entally
friend
ly(rec
ycledan
drecy
clab
le)pa
per.
5167415v3
.0