technical data - muralis architectural - wall systems...
TRANSCRIPT
exterior wall & facade elementstechnical data
standard colors
VECTR™ offers a full line of exterior architectural panels manufactured with TAKTL®, a new Ultra High Performance Concrete (UHPC). Uniting superior strength, durability, and environmental performance with a wide range of pattern, finish and color options, VECTR panels offer a comprehensive array of designs that are simple to specify, easy to install, price competitive, and meet the strict requirements of today’s green building projects.
standard textures & patterns
Custom colors also available.
Custom finishes and patterns also available.
onyx naturalcharcoal stone whitef og sand terracotta
exterior wall & facade elementstechnical data
material properties compressive strength - 126 (MPa) / 18,275 (psi)
flexural strength (matrix) - 19 (MPa) / 2,756 (psi) flexural strength (panel) - 25 (MPa) / 3,626 (psi)
tensile strength - 8 (MPa) / 1,160 (psi) density (thin panel) - 2.3 (to/m³) / 143.5 (lb/ft³)
pull out strength (undercut anchor) shear - 2.015 (kN) / 453 (lbf) tension - 3.59 (kN) / 808.2 (lbf)
TAKTL® is a homogeneous material, with characteristics consistent throughout, including color.
All exterior elements are treated with a hydrophobic nano-coating to protect the material until fully cured.
panel basicspanel sizes
Our largest standard panel size is 3'-10" by 9'-0". All panels will be ½” in thickness unless otherwise specified.Custom sizes and thicknesses are available please contact us for more information.
panel edge options
VECTR™ provides two different panel edge conditions: A square edge (or 90 degree return on the panel) and a quirk miter edge. At the outside corners, the square edge reveals the full thickness of the panel, while the quirk miter minimizes the exposed thickness of the panel and visually maintains the continuity of the panel surface pattern around corners.
panel joints
Joints between panels shall be determined based upon building movement. Thermal movement is negligible and does not affect joint size. Panels cannot be butt joined due to building movement which may cause buckling between adjacent panels. VECTR recommends a minimum 3/16” joint between panels, unless project specific building movement values require greater spacing between panels. Criteria to determine minimal joint sizes based on building movement values should be reviewed by the structural engineer of the project.
thermal movement
The coefficient of expansion for VECTR panels equals 0.01mm/m/deg K, which is extremely low. Over a 38 degree Celsius temperature swing, the movement of a 1 meter long panel is 0.38mm. Therefore special provisions related to thermal movement are not required in the anchorage or joint design of the panel.
Panels ship cut to size and prepped for anchors. Please specify visible or concealed fasteners.
exterior wall & facade elementstechnical data
anchor setback
Edge of undercut anchor or hole for through bolt fastening must be a minimum of 3” from panel edge to comply with pull-out testing requirements.
anchor spacing
For adequate support, panels must have a minimum of four anchors.
Spacing between anchors shall not exceed 39”.
Anchors must be set a minimum of 3” from all panel edges.
anchor types
attachments
exterior wall & facade elementstechnical data
application
cladding over stud wall
cladding over masonry
ventilated rainscreen
Please refer to the VECTR Installation Guide for typical installation details.
exterior wall & facade elementstechnical data
testing & certificationsFor testing materials and perfecting formulations, we have comprehensive in-house testing equipment in our Materials Lab. This equipment allows us to quickly and easily determine whether color formulations, reinforcements and production batches meet our high standards of performance. It also gives us the ability to optimize our production process for efficiency and material strength development by providing a fast, easy way to test samples at different points in the curing process. TAKTL® is initially focusing on certified testing for U.S. and European building codes, partnering with testing labs in Germany and the U.S.
ASTM C293 Flexural Strength (Beam) CompletedASTM C496 Splitting Tensile Strength CompletedASTM C642 Density (Cube) CompletedASTM C642 Voids CompletedASTM C642 Water Absorption (Cube) CompletedASTM C873 Compressive Strength CompletedDIN EN 196-1 Compressive Strength CompletedASTM C531 Thermal Expansion CompletedASTM E136 Fire Testing CompletedASTM C1185 Density (Thin Panel) Completed ASTM C1185 Flexural Strength (Thin Panel) - Dry CompletedASTM C1185 Flexural Strength (Thin Panel) - Wet CompletedASTM C1185 Freeze-Thaw (Cladding) CompletedASTM C1185 Moisture Content (Thin Panel) CompletedASTM C1185 Moisture Movement (Thin Panel) CompletedASTM C1185 Warm Water CompletedASTM C1185 Water Absorption (Thin Panels) CompletedASTM C1185 Water Tightness CompletedASTM E488 Pullout Strength CompletedASTM E84 Surface Burning Characteristics CompletedASTM G155 & D2244 Colorfastness & Weathering Completed
exterior wall & facade elementstechnical data
handling
environmental
technical support & project management
benefits
VECTR™ panels can be cut with standard equipment in the field - we recommend a wet saw with a continuous rim blade and wet drilling with glass or diamond bits. Panels are typically packed and shipped with either under-cut anchors, or through-bolt holes with or without counter-boring. Standard panel sizes have been determined for easy handling by two people. Panels are packed in exterior grade crates, organized and labeled to support installation staging. And VECTR panels are easy to maintain by cleaning with mild nonabrasive detergent and water.
Please contact our technical support staff for environmental impact data or to speak to one of our LEED® Accredited Professionals about the requirements of your project.
Whether you require assistance in design, specification, samples, pricing, or installation, we have a qualified, proactive team of design professionals, engineers, and installation experts to provide technical advice, drawings, and project management services. We are passionate about TAKTL and about helping our clients understand the application and potential of VECTR Exterior Panels.
strength & stability
> higher strength translates to longer spans between anchors and lower installation costs> thinner profiles make elegant forms possible and reduce shipping costs> extremely stable material matrix will not shrink or expand over time> lighter weight results in less material required for foundation and support walls> less material simplifies handling and lowers costs
durability
> chloride diffusion: withstands road and environmental salt> water suction: not susceptible to cracking through freeze-thaw cycles> color: dense material matrix protects pigment and enhances performance> life span: expected life exceeds 100 years
durability
> local materials> regional, low-energy manufacturing> longer life cycle> material efficiency, recyclability
cost
> product: efficiencies of automated manufacturing and local materials> installation: efficient, clear, and thoughtful installation systems for onsite ease and manageability> freight: regional manufacturing, nesting components, less weight
aesthetics
> color: integral, saturated, standard, custom> finish: polished to matte, with fine detail possible> pattern: low relief to highly sculptural
exterior wall & facade elementstechnical data
Cladding Over Studwall
76
ANNOTATION KEY
STUD SUPPORT WALL
NOT TO SCALE
Wall Section Cladding Details
Installation Details
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Sheathing9 - Stud10 - Flashing
1
1
1
1
10
3
3
3
5
5
5
5
6
6
6
7
8
9
8
9
8
9
7
7
4
4
4
3
4
2
2
MID-SECTION DETAIL
BASE DETAIL
COPING DETAIL
www.vectr-arch.com
Cladding Over Studwall
76
ANNOTATION KEY
STUD SUPPORT WALL
NOT TO SCALE
Wall Section Cladding Details
Installation Details
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Sheathing9 - Stud10 - Flashing
1
1
1
1
10
3
3
3
5
5
5
5
6
6
6
7
8
9
8
9
8
9
7
7
4
4
4
3
4
2
2
MID-SECTION DETAIL
BASE DETAIL
COPING DETAIL
www.vectr-arch.com
applicationcladding over stud wall
exterior wall & facade elementstechnical data
98
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Sheathing9 - Stud10 - Flashing11 - Perferated Pro�le12 - Window Frame
1
1
5
6
6
7
7
8
8
8
9
9
9
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
12
10
1
5
6
7
3
4
12
12
10
10
5
4
2
3
11
2
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
8
9
5
5
5
6
6
6
9
8
1
7
7
7
2
2
3
3
4
2
3
1
4
2
3
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Sheathing9 - Stud
Plan Cladding Details
www.vectr-arch.com
98
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Sheathing9 - Stud10 - Flashing11 - Perferated Pro�le12 - Window Frame
1
1
5
6
6
7
7
8
8
8
9
9
9
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
12
10
1
5
6
7
3
4
12
12
10
10
5
4
2
3
11
2
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
8
9
5
5
5
6
6
6
9
8
1
7
7
7
2
2
3
3
4
2
3
1
4
2
3
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Sheathing9 - Stud
Plan Cladding Details
www.vectr-arch.com
cladding over stud wall
application
exterior wall & facade elementstechnical data
98
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Sheathing9 - Stud10 - Flashing11 - Perferated Pro�le12 - Window Frame
1
1
5
6
6
7
7
8
8
8
9
9
9
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
12
10
1
5
6
7
3
4
12
12
10
10
5
4
2
3
11
2
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
8
9
5
5
5
6
6
6
9
8
1
7
7
7
2
2
3
3
4
2
3
1
4
2
3
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Sheathing9 - Stud
Plan Cladding Details
www.vectr-arch.com
98
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
STUD SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Sheathing9 - Stud10 - Flashing11 - Perferated Pro�le12 - Window Frame
1
1
5
6
6
7
7
8
8
8
9
9
9
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
12
10
1
5
6
7
3
4
12
12
10
10
5
4
2
3
11
2
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
8
9
5
5
5
6
6
6
9
8
1
7
7
7
2
2
3
3
4
2
3
1
4
2
3
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Sheathing9 - Stud
Plan Cladding Details
www.vectr-arch.com
cladding over stud wall
application
exterior wall & facade elementstechnical data
Rainscreen
32
ANNOTATION KEY
RAINSCREEN
NOT TO SCALE
Wall Section Details
Installation Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Insulation9 - Flashing10 - Perforated Pro�le
≥ 1 1/4”
≥ 1”
BASE DETAIL
MID-SECTION DETAIL
COPING DETAIL
4
4
4
1
1
1
4
6
6
7
7
3
5
5
5
5
6
7
8
8
8
3
3
1
9
2
10
2
10
3
www.vectr-arch.com3
Rainscreen
32
ANNOTATION KEY
RAINSCREEN
NOT TO SCALE
Wall Section Details
Installation Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Insulation9 - Flashing10 - Perforated Pro�le
≥ 1 1/4”
≥ 1”
BASE DETAIL
MID-SECTION DETAIL
COPING DETAIL
4
4
4
1
1
1
4
6
6
7
7
3
5
5
5
5
6
7
8
8
8
3
3
1
9
2
10
2
10
3
www.vectr-arch.com3
applicationventilated rainscreen
exterior wall & facade elementstechnical data
ANNOTATION KEY
RAINSCREEN
NOT TO SCALE
Window Details
54
RAINSCREEN
NOT TO SCALE
ANNOTATION KEY1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Insulation9 - Connecting Angle
ADJACENT PANELS
OUTSIDE CORNER
INSIDE CORNER
1
1
1
4
4
5
5
5
5
6
6
6
9
8
8
8
1
7
7
7
2
2
9
3
3
4
2
3
1
4
2
34
5
6
7
8
8
11
11
1
9
2
10
3
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
1
4
9
9
5
6
7
2
3
4
5
6
7
8
1
3
Plan Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Insulation9 - Flashing10 - Perferated Pro�le11 - Window Frame
www.vectr-arch.com
ANNOTATION KEY
RAINSCREEN
NOT TO SCALE
Window Details
54
RAINSCREEN
NOT TO SCALE
ANNOTATION KEY1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Insulation9 - Connecting Angle
ADJACENT PANELS
OUTSIDE CORNER
INSIDE CORNER
1
1
1
4
4
5
5
5
5
6
6
6
9
8
8
8
1
7
7
7
2
2
9
3
3
4
2
3
1
4
2
34
5
6
7
8
8
11
11
1
9
2
10
3
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
1
4
9
9
5
6
7
2
3
4
5
6
7
8
1
3
Plan Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Insulation9 - Flashing10 - Perferated Pro�le11 - Window Frame
www.vectr-arch.com
ventilated rainscreen
application
exterior wall & facade elementstechnical data
ANNOTATION KEY
RAINSCREEN
NOT TO SCALE
Window Details
54
RAINSCREEN
NOT TO SCALE
ANNOTATION KEY1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Insulation9 - Connecting Angle
ADJACENT PANELS
OUTSIDE CORNER
INSIDE CORNER
1
1
1
4
4
5
5
5
5
6
6
6
9
8
8
8
1
7
7
7
2
2
9
3
3
4
2
3
1
4
2
34
5
6
7
8
8
11
11
1
9
2
10
3
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
1
4
9
9
5
6
7
2
3
4
5
6
7
8
1
3
Plan Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Insulation9 - Flashing10 - Perferated Pro�le11 - Window Frame
www.vectr-arch.com
ANNOTATION KEY
RAINSCREEN
NOT TO SCALE
Window Details
54
RAINSCREEN
NOT TO SCALE
ANNOTATION KEY1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Insulation9 - Connecting Angle
ADJACENT PANELS
OUTSIDE CORNER
INSIDE CORNER
1
1
1
4
4
5
5
5
5
6
6
6
9
8
8
8
1
7
7
7
2
2
9
3
3
4
2
3
1
4
2
34
5
6
7
8
8
11
11
1
9
2
10
3
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
1
4
9
9
5
6
7
2
3
4
5
6
7
8
1
3
Plan Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Insulation9 - Flashing10 - Perferated Pro�le11 - Window Frame
www.vectr-arch.com
ventilated rainscreen
application
exterior wall & facade elementstechnical data
applicationcladding over masonry
Cladding Over Masonry
1110
ANNOTATION KEY
MASONRY SUPPORT WALL
NOT TO SCALE
Wall Section Cladding Details
Installation Details
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Flashing
MID-SECTION DETAIL
BASE DETAIL
COPING DETAIL
1
1
1
1
8
3
3
3
5
5
5
5
6
6
6
7
7
7
4
4
4
3
4
2
2
www.vectr-arch.com
Cladding Over Masonry
1110
ANNOTATION KEY
MASONRY SUPPORT WALL
NOT TO SCALE
Wall Section Cladding Details
Installation Details
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle8 - Flashing
MID-SECTION DETAIL
BASE DETAIL
COPING DETAIL
1
1
1
1
8
3
3
3
5
5
5
5
6
6
6
7
7
7
4
4
4
3
4
2
2
www.vectr-arch.com
exterior wall & facade elementstechnical data
applicationcladding over masonry
1312
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Flashing9 - Perferated Pro�le10 - Window Frame
1
1
5
6
6
7
7
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
10
8
1
5
6
7
3
4
10
10
8
8
5
4
2
3
9
2
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle9 - Connecting Angle
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
5
5
5
6
6
6
9
1
7
7
7
2
3
3
4
2
3
1
4
2
3
Plan Cladding Details
www.vectr-arch.com
1312
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Flashing9 - Perferated Pro�le10 - Window Frame
1
1
5
6
6
7
7
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
10
8
1
5
6
7
3
4
10
10
8
8
5
4
2
3
9
2
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle9 - Connecting Angle
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
5
5
5
6
6
6
9
1
7
7
7
2
3
3
4
2
3
1
4
2
3
Plan Cladding Details
www.vectr-arch.com
exterior wall & facade elementstechnical data
applicationcladding over masonry
1312
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Flashing9 - Perferated Pro�le10 - Window Frame
1
1
5
6
6
7
7
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
10
8
1
5
6
7
3
4
10
10
8
8
5
4
2
3
9
2
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle9 - Connecting Angle
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
5
5
5
6
6
6
9
1
7
7
7
2
3
3
4
2
3
1
4
2
3
Plan Cladding Details
www.vectr-arch.com
1312
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
MASONRY SUPPORT WALL
NOT TO SCALE
ANNOTATION KEY
Window Details
1 - VECTR Panel2 - Set Screw3 - Panel Clip4 - Undercut Anchor 5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle 8 - Flashing9 - Perferated Pro�le10 - Window Frame
1
1
5
6
6
7
7
3
4
JAMB DETAIL
HEAD DETAIL
SILL DETAIL
10
8
1
5
6
7
3
4
10
10
8
8
5
4
2
3
9
2
1 - VECTR Panel2 - Set Screw3 - Z Pro�le4 - Undercut Anchor5 - Horizontal Rail6 - Vertical Rail7 - Mounting Angle9 - Connecting Angle
INSIDE CORNER
ADJACENT PANELS
OUTSIDE CORNER
1
1
4
4
5
5
5
5
6
6
6
9
1
7
7
7
2
3
3
4
2
3
1
4
2
3
Plan Cladding Details
www.vectr-arch.com