technology center · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011...

9
6458; PARENT LOBBY 6458; RR 6458; THEATER 129 SEATS 6458; DRESSING ROOM 6458; DRESSING ROOM 6458; DANCE STUDIO 6458; DANCE STUDIO 6458; PLATFORM 6458; PARENT LOBBY 6458; RR 6458; THEATER 129 SEATS 6458; DRESSING ROOM 6458; DRESSING ROOM 6458; DANCE STUDIO 6458; DANCE STUDIO 6458; PLATFORM 6458; PARENT LOBBY 6458; RR 6458; THEATER 129 SEATS 6458; DRESSING ROOM 6458; DRESSING ROOM 6458; DANCE STUDIO 6458; DANCE STUDIO 6458; PLATFORM 6458; PARENT LOBBY 6458; RR 6458; THEATER 129 SEATS 6458; DRESSING ROOM 6458; DRESSING ROOM 6458; DANCE STUDIO 6458; DANCE STUDIO 6458; PLATFORM 6458; PARENT LOBBY 6458; RR 6458; THEATER 129 SEATS 6458; DRESSING ROOM 6458; DRESSING ROOM 6458; DANCE STUDIO 6458; DANCE STUDIO 6458; PLATFORM 6458; THEATER 129 SEATS 6458; DANCE STUDIO 6458; PLATFORM FIRE ZONE 1 FIRE ZONE LEGEND GENERAL FIRE PROTECTION NOTES THE SPRINKLER DRAWINGS ARE SCHEMATIC IN NATURE AND ARE MEANT AS A GUIDELINE. THESE PLANS WERE NOT PREPARED FOR SUBMITTAL AND APPROVAL OF THE FIRE SUPPRESSION SYSTEM. A. THE FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED AND SIZED BY THE FIRE PROTECTION CONTRACTOR IN STRICT ACCORDANCE WITH THE LATEST EDITIONS OF THE OHIO BUILDING CODE AND NFPA STANDARDS. SUBMIT DRAWINGS ALONG WITH HYDRAULIC CALCULATIONS & FEES TO THE AUTHORITIES HAVING JURISDICTION FOR APPROVAL. B. REFER TO BOTH THE FP SERIES DRAWINGS AND SPECIFICATION SECTION 211000 FOR SPECIFIC FIRE PROTECTION REQUIREMENTS. HOWEVER, THE SCOPE OF THE FIRE PROTECTION REQUIREMENTS IS NOT LIMITED TO THESE DRAWINGS AND SPECIFICATIONS. REFER TO ALL ARCHITECTURAL DRAWINGS TO BECOME FAMILIAR WITH BUILDING SECTIONS, ELEVATIONS, AND CONDITIONS. C. DESIGN AND MODIFY THE EXISTING AUTOMATIC, WET - TYPE FIRE SUPPRESSION SYSTEM FOR THE HATCHED PROJECT AREA. BASIS OF DESIGN IS LIGHT HAZARD OCCUPANCY EXCEPT AREAS AS INDICATED ON DRAWINGS REQUIRED BY CODE TO BE ORDINARY HAZARD GROUP 1. D. ALL PIPING SHALL BE ABOVE CEILINGS IN FINISHED AREAS AND AS HIGH AS POSSIBLE IN AREAS WITHOUT CEILINGS. E. EXERCISE SPECIAL CARE TO COORDINATE PIPING AND EQUIPMENT LOCATIONS WITH OTHER TRADES. G. REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING PLANS AND CONSTRUCTION DETAILS. COORDINATE SPRINKLER HEAD LOCATIONS WITH CEILING DEVICES (LIGHTS, GRILLES, DIFFUSERS). OBTAIN ARCHITECTS APPROVAL OF SPRINKLER LAYOUT PRIOR TO FABRICATION OR INSTALLATION. FINAL APPEARANCE OF THE WORK MUST BE ACCEPTABLE TO THE ARCHITECT. H. I. OBTAIN AND PAY FOR ALL APPLICABLE FEES AND PERMITS AND ARRANGE FOR ALL NECESSARY INSPECTIONS BY THE AUTHORITIES HAVING JURISDICTION. SPRINKLER CONTRACTOR SHALL INSTALL AUXILIARY DRAINS WHEN A CHANGE IN PIPING DIRECTION PREVENTS DRAINAGE OF SECTIONS OF BRANCH LINES OR MAINS THROUGH THE MAIN DRAIN VALVE. F. 106 MEN 107 WOMEN 105 COMMON AREA 104 STAFF BREAK ROOM 108 TEACHING/QUIET LAB 110 PUBLIC PCs 112 DISCOVERY AREA 114 CONSOLE GAMING 113 VR LABS 111 YOUTH PCs 109 WORK TABLES 103 AV LAB 102 STAFF OFFICE 101 GLOWFORGE 100 MAKER WORKSPACE OUT OF SCOPE DRAWING NOTES MODIFY THE EXISTING WET - PIPE FIRE SUPPRESSION SYSTEM IN THE HATCHED AREA TO ACCOMODATE NEW FLOOR PLAN, PER NFPA 13. A. B. THE EXISTING SPRINKLER SYSTEM WAS DESIGNED BY TYCO FIRE & SECURITY, WEST CHESTER, OH 45069. THE ARCHITECT INDICATED ABOVE HAS BEEN RETAINED SOLEY TO PREPARE DRAWINGS FROM INFORMATION FURNISHED BY THE OWNER AND OTHERS FOR THE PURPOSE OF OBTAINING BUILDING OR OTHER PERMITS FROM APPROPRIATE AGENCIES AS REQUIRED BY THE APPLICABLE BUILDING AND ZONING CODES OR OTHER REGULATIONS, STATUTES, OR ORDINANCES ALL WORK OF THE OWNER OR PERSONS PERFORMING WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL CODES, LAWS, REGULATIONS, ETC. HAVING JURISDICTION OVER THE WORK. COPYRIGHTED 2019 ALL RIGHTS RESERVED DATE COMM NO SHEET NO. 12/16/2019 9:33:05 AM FP100 FIRE PROTECTION PLAN 2019077.02 TECHNOLOGY CENTER LANE LIBRARY 228 COURT ST, HAMILTON, OH 45011 1/8" = 1'-0" FP100 1 FIRE PROTECTION PLAN 22-FIRE PROTECTION SHEET LIST SHEET NUMBER SHEET NAME FP100 FIRE PROTECTION PLAN Submittal 12-17-19

Upload: others

Post on 14-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

6458

;PA

RE

NT

LO

BB

Y

6458

;RR

6458

;TH

EA

TE

R

129

SE

AT

S

6458

;DR

ES

SIN

G R

OO

M

6458

;DR

ES

SIN

G R

OO

M

6458

;DA

NC

E

ST

UD

IO

6458

;DA

NC

E

ST

UD

IO

6458

;PLA

TF

OR

M

6458

;PA

RE

NT

LO

BB

Y

6458

;RR

6458

;TH

EA

TE

R

129

SE

AT

S

6458

;DR

ES

SIN

G R

OO

M

6458

;DR

ES

SIN

G R

OO

M

6458

;DA

NC

E

ST

UD

IO

6458

;DA

NC

E

ST

UD

IO

6458

;PLA

TF

OR

M

6458

;PA

RE

NT

LO

BB

Y

6458

;RR

6458

;TH

EA

TE

R

129

SE

AT

S

6458

;DR

ES

SIN

G R

OO

M

6458

;DR

ES

SIN

G R

OO

M

6458

;DA

NC

E

ST

UD

IO

6458

;DA

NC

E

ST

UD

IO

6458

;PLA

TF

OR

M

6458

;PA

RE

NT

LO

BB

Y

6458

;RR

6458

;TH

EA

TE

R

129

SE

AT

S

6458

;DR

ES

SIN

G R

OO

M

6458

;DR

ES

SIN

G R

OO

M

6458

;DA

NC

E

ST

UD

IO

6458

;DA

NC

E

ST

UD

IO

6458

;PLA

TF

OR

M

6458

;PA

RE

NT

LO

BB

Y

6458

;RR

6458

;TH

EA

TE

R

129

SE

AT

S

6458

;DR

ES

SIN

G R

OO

M

6458

;DR

ES

SIN

G R

OO

M

6458

;DA

NC

E

ST

UD

IO

6458

;DA

NC

E

ST

UD

IO

6458

;PLA

TF

OR

M

6458

;TH

EA

TE

R

129

SE

AT

S

6458

;DA

NC

E

ST

UD

IO

6458

;PLA

TF

OR

M

FIRE ZONE 1

FIRE ZONE LEGEND

GENERAL FIRE PROTECTION NOTES

THE SPRINKLER DRAWINGS ARE SCHEMATIC IN NATURE AND ARE MEANT AS A GUIDELINE. THESE PLANS WERE NOT PREPARED FOR SUBMITTAL AND APPROVAL OF THE FIRE SUPPRESSION SYSTEM.

A.

THE FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED AND SIZED BY THE FIRE PROTECTION CONTRACTOR IN STRICT ACCORDANCE WITH THE LATEST EDITIONS OF THE OHIO BUILDING CODE AND NFPA STANDARDS. SUBMIT DRAWINGS ALONG WITH HYDRAULIC CALCULATIONS & FEES TO THE AUTHORITIES HAVING JURISDICTION FOR APPROVAL.

B.

REFER TO BOTH THE FP SERIES DRAWINGS AND SPECIFICATION SECTION 211000 FOR SPECIFIC FIRE PROTECTION REQUIREMENTS. HOWEVER, THE SCOPE OF THE FIRE PROTECTION REQUIREMENTS IS NOT LIMITED TO THESE DRAWINGS AND SPECIFICATIONS. REFER TO ALL ARCHITECTURAL DRAWINGS TO BECOME FAMILIAR WITH BUILDING SECTIONS, ELEVATIONS, AND CONDITIONS.

C.

DESIGN AND MODIFY THE EXISTING AUTOMATIC, WET-TYPE FIRE SUPPRESSION SYSTEM FOR THE HATCHED PROJECT AREA. BASIS OF DESIGN IS LIGHT HAZARD OCCUPANCY EXCEPT AREAS AS INDICATED ON DRAWINGS REQUIRED BY CODE TO BE ORDINARY HAZARD GROUP 1.

D.

ALL PIPING SHALL BE ABOVE CEILINGS IN FINISHED AREAS AND AS HIGH AS POSSIBLE IN AREAS WITHOUT CEILINGS.

E.

EXERCISE SPECIAL CARE TO COORDINATE PIPING AND EQUIPMENT LOCATIONS WITH OTHER TRADES.

G.

REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING PLANS AND CONSTRUCTION DETAILS. COORDINATE SPRINKLER HEAD LOCATIONS WITH CEILING DEVICES (LIGHTS, GRILLES, DIFFUSERS). OBTAIN ARCHITECTS APPROVAL OF SPRINKLER LAYOUT PRIOR TO FABRICATION OR INSTALLATION. FINAL APPEARANCE OF THE WORK MUST BE ACCEPTABLE TO THE ARCHITECT.

H.

I. OBTAIN AND PAY FOR ALL APPLICABLE FEES AND PERMITS AND ARRANGE FOR ALL NECESSARY INSPECTIONS BY THE AUTHORITIES HAVING JURISDICTION.

SPRINKLER CONTRACTOR SHALL INSTALL AUXILIARY DRAINS WHEN A CHANGE IN PIPING DIRECTION PREVENTS DRAINAGE OF SECTIONS OF BRANCH LINES OR MAINS THROUGH THE MAIN DRAIN VALVE.

F.

106MEN

107WOMEN

105COMMON AREA

104 STAFF BREAK ROOM

108TEACHING/QUIET LAB

110PUBLIC PCs

112DISCOVERY AREA

114CONSOLE GAMING

113VR LABS111

YOUTH PCs

109WORK TABLES

103AV LAB

102STAFF OFFICE

101GLOWFORGE

100MAKER WORKSPACE

OUT OF SCOPE

DRAWING NOTES

MODIFY THE EXISTING WET-PIPE FIRE SUPPRESSION SYSTEM IN THE HATCHED AREA TO ACCOMODATE NEW FLOOR PLAN, PER NFPA 13.

A.

B. THE EXISTING SPRINKLER SYSTEM WAS DESIGNED BY TYCO FIRE & SECURITY, WEST CHESTER, OH 45069.

THE ARCHITECT INDICATED ABOVE HAS BEEN RETAINED SOLEY TO PREPARE DRAWINGS FROM INFORMATION FURNISHED BY THE OWNER AND OTHERS FOR THE PURPOSE OF OBTAINING BUILDING OR OTHER PERMITS FROM APPROPRIATE AGENCIES AS REQUIRED BY THE APPLICABLE BUILDING AND ZONING CODES OR OTHER REGULATIONS, STATUTES, OR ORDINANCES

ALL WORK OF THE OWNER OR PERSONS PERFORMING WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL CODES, LAWS, REGULATIONS, ETC. HAVING JURISDICTION OVER THE WORK.

COPYRIGHTED 2019ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

6/2

019 9

:33:0

5 A

M

FP100

FIREPROTECTION

PLAN

12-13-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

1/8" = 1'-0"FP100

1 FIRE PROTECTION PLAN

22-FIRE PROTECTION SHEET LIST

SHEETNUMBER SHEET NAME

FP100 FIRE PROTECTION PLAN

Submittal

12-17-19

Page 2: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

EWC-1

MB-1

SK-1

IM-1

HWET-1

WH-1

S1

S3

S2

106MEN

107WOMEN

105COMMON AREA

104 STAFF BREAK ROOM

WC-1 L-11/2" C1/2" H

2" V

POCPOC

2" V

3/4" H

S1

3/4" C

POC

2" V

POC

1/2" C

POC

3/4" C

1/2" H1/2" C

POC

MB-1SK-1

IM-1

WH-1

HWET-1

3/4" C

1/2" H

2" V

1/2" C

3/4" H

3/4" C

1/2" C

3" S

1/2" H1/2" C

T/P RELIEF VALVE PIPED TO MOP BASIN

PIPE THERMOMETER

CHECK VALVE

BALL VALVE (TYP)

2" S

2" V

4" S

1/2" C

1/2" C1/2" H

WC-1

L-1

3/4" H

2" V

2" V

2" V

GENERAL PLUMBING NOTES

"GENERAL NOTES" APPLY TO ALL P SERIES DRAWINGS ISSUED FOR THIS PROJECT. "DRAWING NOTES" APPLY ONLY TO THE SHEETS ON WHICH THEY APPEAR.

A.

ALL WORK SHALL BE PERFORMED AND INSTALLED PER THE REQUIREMENTS OF ALL FEDERAL, STATE AND LOCAL CODES, LAWS, REGULATIONS, INSPECTION AGENCIES, UTILITY COMPANIES AND OTHER AUTHORITIES HAVING JURISDICTION.

B.

COORDINATE WITH WORK OF OTHER TRADES TO AVOID INTERFERENCES BEFORE BEGINNING WORK.

C.

D.

E.

INSTALL PIPING IN PIPE CHASES, ABOVE CEILINGS AND IN WALLS. INSTALL HORIZONTAL MAINS AND BRANCHES AS HIGH AS PRACTICAL. MAKE OFFSETS IN PIPING TO AVOID INTERFERENCE WITH WORK OF OTHER TRADES WHETHER SHOWN ON DRAWINGS OR NOT. DO NOT INSTALL LIQUID CARRYING PIPING IN OUTSIDE WALLS, ATTIC SPACES OR ANY OTHER AREAS SUBJECT TO FREEZING TEMPERATURES.

F.

INSTALL VALVES IN ACCESSIBLE LOCATIONS AND IN SUCH A MANNER AS TO BE EASY TO OPERATE. PROVIDE ACCESS PANELS FOR VALVES INSTALLED IN CONCEALED SPACES SUCH AS ABOVE PERMANENT CEILINGS AND IN OR BEHIND WALLS.

G.

PROVIDE ACCESS PANELS FOR ALL EQUIPMENT AND SPECIALTIES SUCH AS WATER HAMMER ARRESTERS OR OTHER DEVICES WHICH MAY REQUIRE ACCESS FOR MAINTENANCE AND OPERATION.

H.

REFER TO SANITARY WASTE AND VENT DIAGRAMS, PIPING SYSTEM SCHEMATICS AND OTHER DETAILS PROVIDED FOR ARRANGEMENT OF PIPING AND FOR SIZES NOT SHOWN ON PLANS. THE STACK DIAGRAMS DO NOT SHOW THE TYPE OF FITTINGS REQUIRED AT ALL CONNECTIONS. CONTRACTOR SHALL REFER TO THE LOCAL CODES AND SPECIFICATIONS.

I.

SLOPE ALL GRAVITY PIPING OF SIZES 3" DIAMETER AND LARGER AT 1/8"/FT. MINIMUM, AND SIZES 2-1/2" DIAMETER AND SMALLER AT 1/4"/FT MINIMUM WHERE NOT OTHERWISE INDICATED.

PLUMBING SCHEDULES IDENTIFY THE BASIS OF DESIGN MANUFACTURER AND MODEL. REFER TO SPECIFICATIONS FOR ADDITIONAL APPROVED MANUFACTURERS.

(THERE MAY BE SYMBOLS LISTED IN THIS LEGEND THAT ARE NOT USED IN THIS SET OF DRAWINGS)

PIPE CONTINUES

KEYNOTE NOTE

BALL VALVE

PIPE TURNING DOWN

PIPE TURNING UP

SYMBOLS AND ABBREVIATIONS LEGEND

ABBR DESCRIPTION

C

H

DOMESTIC COLD WATER

DOMESTIC HOT WATER

POINT OF CONNECTION

?

FLOOR CLEANOUTFCO

GRADE CLEANOUTGCO

FLOOR DRAINFD-#

POC

4" - C

PIPE TAG LEGEND

PIPE SIZE (DIA.) PIPE SYSTEM TYPE

SANITARYS

V VENT

PD1

106MEN

107WOMEN

105STAFF RESTROOM

104 STAFF BREAK ROOM

PD1

PD1

PD1

HANGER ROD

LOCKING NUT

HEAVY DUTYCLEVIS HANGER

14 GAUGE ZINC COATSSHEET STEEL SADDLEAT LEAST 6" LONG

NOTE:PROVIDE CHROME PLATED ESCUTCHEON TRIM FLANGES AT ALL PIPE PENETRATIONS THRU WALLS

1/2" 105º TW TO FAUCET

ASSE 1070 - T/P POINT OF USE THERMOSTATIC MIXING VALVE W/ INTEGRALSTOPS AND CHECKS SET OUTLET AT 105º F.

1/2" 120º HW SUPPLY TOMIXING VALVE

1/2" HW SUPPLY STOP

1/2" CW SUPPLY TO MIXING VALVE

NOTE:STAINLESS STEEL, COUNTER SINKS WITH THERMOSTATIC MIXING VALVE SIMILIAR, SET OUTLET AT 105º. REFER TO PLANS AND PLUMBING FIXTURE SCHEDULE.

1/2" CW SUPPLY STOP

1/2" CW SUPPLY TO FAUCET

LAV - REFER TO PLANS ANDPLUMBING FIXTURE SCHEDULE

THE ARCHITECT INDICATED ABOVE HAS BEEN RETAINED SOLEY TO PREPARE DRAWINGS FROM INFORMATION FURNISHED BY THE OWNER AND OTHERS FOR THE PURPOSE OF OBTAINING BUILDING OR OTHER PERMITS FROM APPROPRIATE AGENCIES AS REQUIRED BY THE APPLICABLE BUILDING AND ZONING CODES OR OTHER REGULATIONS, STATUTES, OR ORDINANCES

ALL WORK OF THE OWNER OR PERSONS PERFORMING WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL CODES, LAWS, REGULATIONS, ETC. HAVING JURISDICTION OVER THE WORK.

COPYRIGHTED 2019ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

6/2

019 9

:33:1

0 A

M

P100

PLUMBINGPLAN

12-13-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

1/4" = 1'-0"P100

2 PLUMBING PLANP100

3 PLUMBING PLAN ISOMETRIC

22-SINK SCHEDULE

TYPELABEL DESCRIPTION

BASIS OF DESIGN SUPPLY CONNECTION SIZES WASTE CONNECTION SIZES FAUCET SUPPLY STOP DRAIN P - TRAP

MANUFACTURER MODEL COLD WATER HOT WATER DRAIN P - TRAP WASTE LINE VENT MANUFACTURER MODEL MANUFACTURER MODEL MANUFACTURER MODEL MANUFACTURER MODEL

SK-1 COUNTERTOP SINK / STAINLESS STEEL / SINGLE BOWL JUST SL-2217-A-GR 1/2" 1/2" 1.5" 1.5" 1.5" 1.5" ZURN Z871B4-XL McGUIRE H165LK McGUIRE 1151AWC McGUIRE B8912

22-ELECTRIC WATER COOLER AND DRINKING FOUNTAIN SCHEDULE

TYPELABEL DESCRIPTION

FIXTURE

MOUNTING HEIGHTCOLD WATERCONNECTION

WASTE CONNECTION SIZES SUPPLY STOP P-TRAP

BASIS OF DESIGN

P - TRAP DRAIN WASTE LINE VENT MANUFACTURER MODEL MANUFACTURER MODELMANUFACTURER MODEL

EWC-1 COMBINATION WATER COOLER - BOTTLE FILLER / WALL HUNG / ADA / BI-LEVEL ELKAY LZSTL8WSLP 36" / 42" TO BUBBLER 1/2" 1.5" 1.5" 1.5" 1.5" McGUIRE H165LK McGUIRE B8902

22-MOP BASIN SCHEDULE

TYPELABEL DESCRIPTION

BASIS OF DESIGN MOUNTINGHEIGHT

SUPPLY CONNECTIONSIZES WASTE CONNECTION SIZES FAUCET MISC. ACCESSORY

MANUFACTURER MODEL COLD WATER HOT WATER DRAIN P - TRAP WASTE LINE VENT MANUFACTURER MODEL MANUFACTURER MODEL

MB-1 MOP BASIN / FLOOR SET / 24" x 24" x 10" E.L. MUSTEE 63M 36" TO FAUCET 1/2" 1/2" 3" 3" 3" 1.5" ZURN Z843M1-RC E.L. MUSTEE 65.7, 65.6

22-WATER HEATER SCHEDULE

TYPELABEL

BASIS OF DESIGNTANK

VOLUME TYPE OF FUEL

RECOVERYCAPACITY @ 90°F

RISE

ELECTRICAL CHARACTERISTICS

MANUFACTURER MODEL VOLT WATTS Ø

WH-1 LOCHINVAR JRJ006KS 6 GALLONS ELECTRIC 8 GPH 120 1650 1

22-EXPANSION TANK SCHEDULE

TYPELABEL

BASIS OF DESIGN FLUIDTYPE

MAX DESIGNPRESSURE

MAX DESIGNTEMPERATURE

TANKVOLUME

ACCEPTANCEVOLUMEMANUFACTURER MODEL

HWET-1 WESSELS T-5 WATER 150 PSI 240° F 2.1 GALLONS 1.3 GALLONS

22-THERMOSTATIC MIXING VALVE SCHEDULE

TYPELABEL

BASIS OF DESIGN MINIMUMFLOW

FLOW @ 15 PSIDROP

CONNECTION SIZES

MANUFACTURER MODEL INLET OUTLET

TMV-1 BRADLEY S59-4000 0.35 3.0 GPM 1/2" 1/2"

1/4" = 1'-0"P100

1 PLUMBING DEMOLITION PLAN

P100

5 PIPE HANGER (6" AND SMALLER)

P100

4 POINT OF USE MIXING VALVE

KEYNOTES

PD1 PLUMBING FIXTURE TO BE DEMOLISHED. CAP CONNECTED PIPINGFOR FUTURE CONNECTION.

S1 CONNECT TO EXISTING SUPPLY AND WASTE PIPING AT WALL.

S2 WATER HEATER WH-1 INSTALLED ON SHELF 7'-0" A.F.F. IN CUSTODIALCLOSET. RELIEF VALVE SHALL BE PIPED TO MOP SINK.

S3 ICE MAKER BOX IM-1 INSTALLED 40" A.F.F.

22-PLUMBING SHEET LIST

SHEETNUMBER SHEET NAME

P100 PLUMBING PLAN

22-CONNECTION BOX SCHEDULE

TYPELABEL DESCRIPTION

BASIS OF DESIGN

MOUNTING HEIGHT

SUPPLY CONNECTION SIZES

MANUFACTURER MODEL COLD

IM-1 ICE MAKER CONNECTION BOX GUY GRAY BIM 875 40" TO BOTTOM OF BOX 1/2"

POC

POC

POC Submittal

POC

POC

POC

POC

22-LAVATORY SCHEDULE

TYPELABEL DESCRIPTION

BASIS OF DESIGN MOUNTINGHEIGHT

SUPPLY CONNECTION SIZES WASTE CONNECTION SIZES FAUCET SUPPLY STOP DRAIN P - TRAP

MANUFACTURER MODEL COLD WATER HOT WATER DRAIN P - TRAP WASTE LINE VENT MANUFACTURER MODEL MANUFACTURER MODEL MANUFACTURER MODEL MANUFACTURER MODEL

L-1 LAVATORY / WALL MOUNT ZURN Z5360 34" TO RIM 1/2" 1/2" 1.5" 1.5" 1.5" 1.5" ZURN Z7440-XL McGUIRE H165LK McGUIRE 155A McGUIRE B8902

22-WATER CLOSET SCHEDULE

TYPELABEL DESCRIPTION

BASIS OF DESIGN

MOUNTINGHEIGHT

COLD WATERCONNECTION

WAST CONNECTION SIZES FLUSH VALVE MISC. ACCESSORY

MANUFACTURER MODEL DRAINWASTE

LINE VENT FLUSH RATE MANUFACTURER MODEL

WC-1 WATER CLOSET / FLOOR MOUNT / TANK TYPE KOHLER K-3493 17" TO RIM 1/2" 4" 4" 2" 1.6 GPF - -

POC

12-17-19

Page 3: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

SD-1

150 CFM

SD-1

150 CFM

SD-3

400 CFM

SD-5

500 CFM

SD-5

500 CFM

SD-6

700 CFM

SD-2

250 CFM

SD-2

250 CFM

POC

POC

POC

POCPOC

POC POC

POCPOC

POC

POC

POC

POC

POC

10"ø

POC

14"x14"

M4

M3

M2

8"ø

POC

SD-2

250 CFM

SD-3

400 CFM SD-3

425 CFM SD-2

250 CFM

SD-3

400 CFM

POC

ECG-1

225 CFM

ECG-1

225 CFM

SD-4

600 CFM

POCSD-1

150 CFM

POC

M6

M6

M6

ECG-1

ECG-1

ECG-1

M1

M7

M8

ECG-1

70 CFM

POC

SD-2

300 CFM

10"x12"10"x12"

10"x12" 10"x12"

LSD-1

200 CFM

LSD-1

200 CFM

LSD-1

200 CFM

LSD-1

200 CFM

LSD-1

200 CFM

LSD-1

200 CFM

LSD-1

200 CFM

LSD-1

200 CFM

GENERAL NOTES

A.

B.

DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW DESIGN INTENT. IF CHANGES ARE MADE DUE TO DIFFERING FIELD CONDITIONS, SUGGESTED CHANGES ARE TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO CHANGES BEING MADE.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIRE-RATED WALLS.

C. REPAIR ANY WORK DAMAGED AS A RESULT OF WORK BY THIS CONTRACT.

D. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS, LABOR, PERMITS, INSPECTIONS, FEES, FINAL CLEANUP PERTAINING TO THE MATERIALS, AND QUALITY OF WORKMANSHIP AND MATERIALS.

E. MECHANICAL CONTRACTOR SHALL VERIFY AND SATISFY THAT ALL EQUIPMENT FURNISHED WILL PROPERLY FIT IN THE SPACE PROVIDED, THAT IT WILL FUNCTION PROPERLY, AND THAT ALL PARTS OF EQUIPMENT REQUIRING SERVICE ARE READILY ACCESSIBLE IN COMPLIANCE WITH THE MECHANICAL CODE.

F. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL CUTTING AND PATCHING OF WALLS, FLOORS, AND ROOFS REQUIRED FOR INSTALLATION OF THEIR WORK WITH THE WALL, FLOOR OR ROOF CONTRACTOR DOING THAT WORK. ALL OPENINGS IN WALLS, FLOORS OR CEILINGS SHALL BE PROPERLY SEALED.

G. LOCATE WALL OPENINGS FOR DUCTS, GRILLES, AIR TRANSFER OPENINGS, PIPING, ETC. CENTERED BETWEEN FRAMING MEMBERS WHEN POSSIBLE.

H.

I.

ALL TRANSFER AIR DUCTS SHALL HAVE INTERIOR DUCT LINING. REFER TO THE SPECIFICATIONS FOR DUCT LINING REQUIREMENTS.

J.

ALL DUCT FITTINGS SHALL BE LO-LOSS FITTINGS. ROUND TAPS INTO SQUARE DUCT SHALL BE CONICAL OR BELLMOUTH. SQUARE ELBOWS AND SQUARE OR RECTANGULAR SPLITTERS SHALL USE TURNING VANES. NON-SQUARE ELBOWS SHALL HAVE A MINIMUM RADIUS OF 1.5 TIMES THE RADIUS OF THE DUCT. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIRMENTS.

K.

WHEN PENETRATING A NON-FIRE RATED WALL OR FLOOR WITH DUCTWORK OR PIPING, SEAL ANNULAR SPACE BETWEEN WALL/FLOOR AND MECHANICAL MATERIALS WITH NON-COMBUSTIBLE FIBERGLASS INSULATION AND JOINT SEALANTS APPROPRIATE FOR SIZE AND DEPTH AND SOUND ATTENUATION CONSIDERATION. REFER TO ARCHITECTURAL SPECIFICATIONS FOR NON FIRE RATED JOINT SEALANTS.

L.

M.

BALANCE AIR HANDLING UNIT MINIMUM OUTSIDE AIR TO THE OUTSIDE AIRFLOWS INDICATED ON THE VENTILATION SCHEDULE.

N.

LOCATE ALL TEMPERATURE, PRESSURE, AND FLOW MEASURING DEVICES IN ACCESSIBLE LOCATIONS WITH STRAIGHT SECTION OF PIPE OR DUCT UP AND DOWNSTREAM AS RECOMMENDED BY THE MANUFACTURER FOR ACCURACY.

O.

ALL WORK SHALL BE PERFORMED AND INSTALLED PER THE REQUIREMENTS OF ALL FEDERAL, STATE AND LOCAL CODES, LAWS, REGULATIONS, INSPECTION AGENCIES, UTILITY COMPANIES AND OTHER AUTHORITIES HAVING JURISDICTION

P.

Q.

OUTDOOR DESIGN CONDITIONS: SUMMER - 91 DB, 73 WB. WINTER - 6 DB.

R.

GENERAL ROOM DESIGN CONDITIONS: SUMMER - 75 DB, 30-60% RH. WINTER - 70 DB.

S.

THE USE OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO AIR DEVICE CONNECTIONS AND BE A MAXIMUM OF 60” IN LENGTH.

T.

ALL 90° ELBOWS SHALL BE SHEET METAL.

U.

DUCT RUN-OUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED OTHERWISE.

V.

W.

PROVIDE VOLUME CONTROL DAMPERS IN RUN-OUT DUCT TO ALL SUPPLY AIR DEVICES.

X.

CONTRACTOR TO SECURE AND PAY FOR ALL LICENSES, PERMITS OR FEES REQUIRED TO PERFORM THIS WORK.

Y.

TURNING VANES SHALL BE INSTALLED IN ALL SUPPLY DUCT TURNS.

Z.

COORDINATE LOCATIONS OF ALL HVAC EQUIPMENT AND ACCESSORIES WITH OTHER TRADES.

MAINTAIN REQUIRED CLEARANCES FROM EXHAUST AND VENT LOCATIONS TO OUTSIDE AIR INTAKE AND OPERABLE DOORS & WINDOWS.

PROVIDE DUCT LINER PER SPECIFICATIONS FOR ALL SUPPLY DUCT WITHIN 10’ OF CONNECTION TO ALL AIR HANDLING EQUIPMENT INCLUDING ROOFTOP UNITS, FAN COILS, HEAT PUMPS, AND AIR HANDLERS.

MECHANICAL CONTRACTOR TO DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT, DUCTWORK, SUPPORTS, CONTROLS, PIPING, ETC. NOT REUSED IN THE FINAL DESIGN.

THERMOSTATS SHALL BE MOUNTED WITH BOTTOM AT 44" ABOVE FINISHED FLOOR.

1/8" = 1'-0"M100

3 FIRST FLOOR DEMO PLAN 1/8" = 1'-0"M100

4 FIRST FLOOR DUCTWORK PLAN

THE ARCHITECT INDICATED ABOVE HAS

BEEN RETAINED SOLEY TO PREPARE

DRAWINGS FROM INFORMATION FURNISHED

BY THE OWNER AND OTHERS FOR THE

PURPOSE OF OBTAINING BUILDING OR

OTHER PERMITS FROM APPROPRIATE

AGENCIES AS REQUIRED BY THE

APPLICABLE BUILDING AND ZONING CODES

OR OTHER REGULATIONS, STATUTES, OR

ORDINANCES

ALL WORK OF THE OWNER OR PERSONS

PERFORMING WORK SHALL CONFORM TO

THE REQUIREMENTS OF ALL CODES, LAWS,

REGULATIONS, ETC. HAVING JURISDICTION

OVER THE WORK.

COPYRIGHTED 2019

ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

7/2

019 1

1:3

8:1

7 A

M

M100

HVACDUCTWORK

PLAN

12-17-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

KEYNOTES

M1 PROVIDE MANUAL BALANCING DAMPER IN VERTICAL DUCT.

M2 DUCT CONTINUES TO RTU-4. TYP.

M3 DUCT CONTINUES TO RTU-5. TYP.

M4 KEEP EXISTING RUNOUTS AND ADJUST EXISTING DAMPER TO NOTED CFM. TYP.

M6 REPLACE EXISTING EGG CRATE GRILL.

M7 PROVIDE ALUMINUM HOODED DRYER VENT IN EXTERIOR WALL WITH BACK DRAFT DAMPER.

M8 ROUTE 4" ROUND DUCT DOWN AND CONNECT TO CNC/GLOWFORGE

Submittal

23-AIR DEVICE SCHEDULE

MARK

BASIS OF DESIGN

DIFFUSER TYPE

MAXIMUM

AIRFLOW

MAXIMUM

PRESSURE DROP

MAXIMUM

SOUND

CONNECTION

SIZE FACE SIZE NOTESMANUFACTURER MODEL

ECG-1 PRICE 80 EGG CRATE CRILLE 720 CFM 0.085 in-wg 20 12" X 12" 12" X 12"

LSD-1 PRICE SDS75 LINEAR SLOT DIFFUSER 280 CFM 0.070 in-wg 25 10" Ø 48" X 6"

SD-1 PRICE SPD SQUARE PLAQUE DIFFUSER 157 CFM 0.237 in-wg 20 6" Ø 12" X 12"

SD-2 PRICE SPD SQUARE PLAQUE DIFFUSER 350 CFM 0.115 in-wg 27 8" Ø 24" X 24"

SD-3 PRICE SPD SQUARE PLAQUE DIFFUSER 490 CFM 0.146 in-wg 26 10" Ø 24" X 24"

SD-4 PRICE SPD SQUARE PLAQUE DIFFUSER 630 CFM 0.166 in-wg 25 12" Ø 24" X 24"

SD-5 PRICE RCD/RCDA ROUND CONE DIFFUSER 630 CFM 0.109 in-wg 27 12" Ø 27" Ø

SD-6 PRICE RCD/RCDA ROUND CONE DIFFUSER 850 CFM 0.109 in-wg 28 14" Ø 31.5" Ø

Page 4: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

DESCRIPTIONSYMBOLDEFAULT MOUNTING

HEIGHT

LIGHTING CONTROL SYMBOL LEGEND

OCCUPANCY SENSOR -LIGHTING CONTROL

CEILING

LIGHTING SWITCH(# OF " " INDICATES NUMBER OF SWITCHES)

SWITCH TYPE, IF OMITTED, SWITCH IS SINGLE POLE.3 = 3 WAY4 = 4 WAYOS1 = OCCUPANCY SENSORT = TIME SWITCHD = DIMMER

OCCUPANCY SENSOR -LIGHTING CONTROL

10'-0"AFFWALL MOUNTED

XXX

DESCRIPTIONSYMBOLMOUNTING

HEIGHT

TECHNOLOGY SYMBOL LEGEND

LCD PROJECTOR

MOUNTING HEIGHT OF BACKBOX, IF OMITTED DEFAULT MOUNTING HEIGHT IS 18"

TYPE OF TECHNOLOGY OUTLET.

TECHNOLOGY OUTLET

TECHNOLOGY TYPES

PS POWER SUPPLY2D (2) DATA OUTLETS4D (4) DATA OUTLETSTV TV MONITORP PROTECTORTC TEACHER'S COMPUTERSC STUDENT'S COMPUTERLC LAPTOP CART

XX/44"

GENERAL NOTES: - APPLIES TO ALL ELECTRICAL DRAWINGS

EC SHALL BE RESPONSIBLE TO INSTALL A SWITCH BOX AND 3/4" CONDUIT TO ABOVE THE CEILING IN EACH ROOM FOR TEMPERATURE CONTROL THERMOSTAT. REFER TO THE MECHANICAL DRAWINGS FOR LOCATIONS OF THESE DEVICES.

EC MAY COMBINE MULTIPLE CIRCUITS INTO HOME RUNS. NO MORE THAN 3 CIRCUITS SHALL BE IN EACH HOME RUN CONDUIT, AND THE WIRE MUST BE DERATED IN ACCORDANCE WITH NEC. THESE CIRCUITS SHALL BE REQUIRED TO BE ON SEPARATE PHASES (A,B,C).

EC SHALL DERATE WIRE IN LONG RUNS ACCORDING TO THE WIRE SIZING TABLE SHOWN BELOW:

WIRE SIZING CHART

RUN LENGTH

277V120V

CIRCUIT BREAKER

20A 30A 40A

000-200'000-100' 12 10 8

201-300'101-150' 10 8 6

301-450'151-200' 8 6 4

WHERE ELECTRICAL LOAD ON A CIRCUIT IS OVER 20 AMPERES, EACH CIRCUIT SHALL BE RUN IN A SEPARATE CONDUIT TO THE PANELBOARD.

ALL VAV BOXES, EXHAUST FANS, MOTORS, MISC. HVAC EQUIPMENT, APPLIANCES, ETC. INDICATED ON THESE DRAWINGS SHALL HAVE A MOTOR RATED SWITCH LOCATED NEAR THE MOTOR FOR SERVICING. PROVIDE DISCONNECTING MEANS AS REQUIRED BY THE NEC.

EMERGENCY CIRCUITS SHALL BE INSTALLED IN A SEPARATE CONDUIT SYSTEM.

ALL PANELBOARDS SHALL BE INSTALLED 72" AFF TO THE TOP OF THE PANEL. PROVIDE 10% SPARE CONDUITS (MINIMUM OF 4) TO ABOVE THE CEILING FOR FUTURE.

ALL DATA OUTLETS REQUIRE A MINIMUM OF 1" CONDUIT STUB TO ABOVE CEILING. PROVIDE A 3-1/2" DEEP BOX MINIMUM FOR ALL DATA OUTLETS.

HEIGHT DIMENSIONS SHOWN ON THIS PLAN ARE MEASURED FROM THE BOTTOM OF THE DEVICE. HORIZONTAL DIMENSIONS ARE MEASURED TO THE CENTER OF THE DEVICE OR GROUP OF DEVICES WHICH THE DIMENSION PERTAINS TO.

FOR LIGHT FIXTURE MOUNTING DETAILS, SEE LUMINAIRE SCHEDULE, ON SHEET E000.

A.

B.

C.

D.

E.

F.

G.

H.

J.

K.

PROJECTOR RECEPTACLE

(CLG MOUNTED)

SPECIAL NOTE (IF USED)CNC = CNC MACHINEGLOW = GLOW FORGETV = TV MONITOR. COORDINATE WITH EQUIPMENT PROVIDER.PR = PRINTERREF = REFRIGERATOR @ 60"AFFSC = STUDENT COMPUTERSTC = TEACHER'S COMPUTERLC = LAPTOP CARTCR = CORD REEL

SPECIALTY RECEPTACLE

XX/44"

P

MOUNTING HEIGHT OF BACKBOX, IF OMITTED DEFAULT MOUNTING HEIGHT IS 16"

GROUND FAULTPROTECTED

GROUND FAULTPROTECTED,

ABOVE COUNTER

EMERGENCYCIRCUIT

ABOVE COUNTER

DUPLEX

DOUBLE-DUPLEX

FB#

FLOOR BOX

FB1 = POWER AND DATA CONNECTIONS

FB2 = POWER CONNECTIONS TO FURNITURE (WHIP) VERIFY EXACT REQUIREMENTS WITH FURNITURE SUPPLIER.

DEVICE LEGENDWIRING DEVICES

DEVICE LEGENDFLOOR BOXES

LIGHTING FIXTURES

GENERAL NOTES - LIGHTING FIXTURES:

ALL FIXTURES MARKED 'ED' ARE EXISTING TO BE DEMOLISHED. VERIFY SERVING PANEL AND CIRCUIT NUMBER PRIOR TO DISCONNECTION. REMOVE LIGHTING BRANCH CIRCUITING ABOVE FINISHED CEILING. MAINTAIN HOME RUN CONDUIT FOR CONNECTION TO NEW FIXTURES.

A.

ALL FIXTURES MARKED 'ER' ARE EXISTING TO REMAIN. FIXTURES SHALL BE CLEANED AND RELAMPED.B.

REFER TO LIGHTING CONTROL SCHEMATICS AND LIGHTING CIRCUIT SCHEDULES ON E510 SERIES DRAWINGS.

C.

2' x 4' LIGHT- CAPITAL LETTER WITH NUMBER NOTES FIXTURE TYPE, REFER TO LIGHT FIXTURE SCHEDULE BELOW.- SMALL LETTER NOTES SWITCH LEG/RELAY NUMBER -REFER TO E510 SERIES DRAWINGS FOR TYPICAL ROOM LAYOUTS.-FILLED IN AREA DENOTES EMERGENCY FIXTURE - CONNECT TO EXISTING EMERGENCY POWER CIRCUIT AHEAD OF SWITCHING.

A1b

DUAL HEAD EMERGENCY FIXTUREE1

EXIT FIXTURE - SHADED IN AREA DENOTES FACE SIDE - ARROW DENOTES ARROW DIRECTION

X10

2' x2' LIGHTA1D1 RECESSED CAN LIGHT

1' x 4' LIGHT A1

LINEAR PENDANT FIXTUREB1

MECHANICAL EQUIPMENT

GENERAL NOTES - MECHANICAL EQUIPMENT:

COORDINATE ALL ELECTRICAL REQUIREMENTS, INCLUDING ROUGH-IN LOCATION, CONNECTION TYPE, AND POWER REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.

A.

WIRING TERMINATIONS TO EQUIPMENT SHALL BE DONE PER MANUFACTURER'S WRITTEN INSTRUCTIONS.B.

LOCATIONS OF DEVICES SHOWN ON DRAWINGS ARE SCHEMATIC IN NATURE. COODINATE LOCATIONS WITH EQUIPMENT INSTALLER.

C.

S

TATE OF OHIO

PR

OF

ESSIONAL ENG

INE

ER

JAMES B.MESSNERE-74397

THE ARCHITECT INDICATED ABOVE HAS

BEEN RETAINED SOLEY TO PREPARE

DRAWINGS FROM INFORMATION FURNISHED

BY THE OWNER AND OTHERS FOR THE

PURPOSE OF OBTAINING BUILDING OR

OTHER PERMITS FROM APPROPRIATE

AGENCIES AS REQUIRED BY THE

APPLICABLE BUILDING AND ZONING CODES

OR OTHER REGULATIONS, STATUTES, OR

ORDINANCES

ALL WORK OF THE OWNER OR PERSONS

PERFORMING WORK SHALL CONFORM TO

THE REQUIREMENTS OF ALL CODES, LAWS,

REGULATIONS, ETC. HAVING JURISDICTION

OVER THE WORK.

COPYRIGHTED 2019

ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

7/2

019 7

:21:0

7 A

M

E000

ELECTRICALLEGENDS

12-17-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

26-ELECTRICAL SHEET LIST

SHEETNUMBER SHEET NAME

E000 ELECTRICAL LEGENDS

E010 ELECTRICAL DEMOLITION PLAN

E100 LIGHTING PLAN

E200 POWER PLAN

E400 SCHEDULES & SINGLE LINE DIAGRAM

E510 LIGHTING DETAILS

LIGHT FIXTURE SCHEDULE

FIXTURETYPE

FIXTURE BASIS OFDESIGN ALTERNATE MANUFACTURERS FIXTURE DESCRIPTION

BALLASTQUANTITY BALLAST TYPE

BALLASTFACTOR

BALLASTVOLTAGE

BALLAST MAXIMUMINPUT WATTAGE

NUMBER OFLAMPS LAMP MOUNTING METHOD TYPE COMMENTS

A10 LITHONIA 2BLT COLUMBIA LCAT24, LSI LPASC,METALUX 24CZ

RECESSED TROFFER, LED, 2'x4'x3-3/4"DEEP, STEEL CONSTRUCTION, DLCRATED, 4000 LUMEN

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 34 VA N/A LED - 4000K CEILING GRID

A10E LITHONIA 2BLT COLUMBIA LCAT24, LSI LPASC,METALUX 24CZ

RECESSED TROFFER, LED, 2'x4'x3-3/4"DEEP, STEEL CONSTRUCTION, DLCRATED, 4000 LUMEN, EMERGENCY BATTERY

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 34 VA N/A LED - 4000K CEILING GRID

C10 LITE-CONTROL 4L-S-D APPROVED EQUAL LINEAR DIRECT, PRENDANT MOUNTED, LENGTH AS SHOWN ON THEPLANS, MATTE WHITE FINISH, 800 LUMENS/LF, SOFT DIFFUSE LENSE.

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 30 VA N/A LED - 4000K PENDANT MOUNT EVEN WITH BOTTOM OF CEILING FABRIC

C10E LITE-CONTROL 4L-S-D APPROVED EQUAL LINEAR DIRECT, PRENDANT MOUNTED, LENGTH AS SHOWN ON THEPLANS, MATTE WHITE FINISH, 800 LUMENS/LF, SOFT DIFFUSE LENSE,EMERGENCY BATTERY

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 30 VA N/A LED - 4000K PENDANT MOUNT EVEN WITH BOTTOM OF CEILING FABRIC

D10 PRESCOLITE LC4LED INDY L4, OMEGA OM4LED, SPECTRUMSGE4LED, PORTFOLIO LD4A, PATHWAY4VLFL

4" RECESSED DOWN LIGHT, 1000 LUMENS, PAINTED WHITE TRIM,SEMI-SPECULAR ALZAK REFLECTOR

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 14 VA N/A LED - 4000K CEILING

D10E PRESCOLITE LC4LED INDY L4, OMEGA OM4LED, SPECTRUMSGE4LED, PORTFOLIO LD4A, PATHWAY4VLFL

4" RECESSED DOWN LIGHT, 1000 LUMENS, PAINTED WHITE TRIM,SEMI-SPECULAR ALZAK REFLECTOR

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 14 VA N/A LED - 4000K CEILING

D20 PRESCOLITE LC4LED INDY L4, OMEGA OM4LED, SPECTRUMSGE4LED, PORTFOLIO LD4A, PATHWAY4VLFXWL

6" RECESSED DOWN LIGHT, 1400 LUMENS, PAINTED WHITE TRIM,SEMI-SPECULAR ALZAK REFLECTOR

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 18 VA N/A LED - 4000K CEILNG

D20E PRESCOLITE LC4LED INDY L4, OMEGA OM4LED, SPECTRUMSGE4LED, PORTFOLIO LD4A, PATHWAY4VLFXWL

6" RECESSED DOWN LIGHT, 1400 LUMENS, PAINTED WHITE TRIM,SEMI-SPECULAR ALZAK REFLECTOR,EMERGENCY BATTERY

N/A LED DRIVER, 0-10VDIMMING

N/A 120 V 18 VA N/A LED - 4000K CEILNG

G20 TBD APPROVED EQUAL PENDANT, 4"DIA, GLASS SHADE, PENDANT MOUNT N/A LED DRIVER N/A 120 V 6 VA N/A LED CEILING CANOPY

G21 TBD APPROVED EQUAL PENDANT, 4"DIA, GLASS SHADE, PENDANT MOUNT N/A LED DRIVER N/A 120 V 6 VA N/A LED CEILING CANOPY

REH LITHONIA ELA EQUALS BY JUNO, BEGHELLI USA, ORDUAL-LITE

WALL MOUNT, EXTERIOR, DUAL REMOTE HEADS, WEATHERPROOF,COLOR TO BE SELECTED BY ARCHITECT, CAST ALUMINIUM

N/A LED N/A 120 V 2 VA N/A LED WALL MOUNTED WIRE TO ADJACENT EXIT SIGN

X10 DUAL-LITE EVE LITHONIA LQM, APPROVED EQUAL EXIT SIGN, SINGLE FACE, RED LETTERS, THERMOPLASTIC HOUSING,REMOTE HEAD CAPABILITY, DIRECTIONAL ARROWS AS SHOWN ON THEPLANS, WHITE HOUSING, EMERGENCY BATTERY BACKUP.

N/A LED N/A 120 V 5 VA N/A LED WALL/CEILING MOUNT WIRED TO UNSWITCHED CIRCUIT

26-EQUIPMENT SCHEDULE - MECHANICAL

EQUIPMENTNAME

SPECIFICATIONSECTION STARTER TYPE

STARTERPROVIDED BY

STARTERINSTALLED

BY STARTER LOCATION DISCONNECT TYPEDISCONNECTPROVIDED BY

DISCONNECTINSTALLED BY DISCONNECT LOCATION Panel Circuit Number Notes

WH-1 22 CONTROL PANEL DIV. 22 DIV. 22 INTEGRAL TO UNIT MRTS DIV. 26 DIV. 26 NEAR UNIT EX-A2 51

Submittal

jmessner
Text Box
EMERGENCY BATTERY
jmessner
Signature
jmessner
Text Box
12/17/19
Page 5: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

ED

ER

ED

ED

ER

ER

3 ED

ED

ED

ED

ED

3 E

D

ED

3 ED

3 E

R

ED

3 E

D3 E

D

ED

ED

ED

ED

ER

ED ER ER

ED

ED

ED

ER

ER

ER

ED

ED

ER

ED

ED

EDED

ER

ED

ER

ED

ER

ED

ED

ED

ER

ER

ER

ER

ED

ED

ER

ER ER

ER

ER

ER

ED

ER

ED

ER

ER

ER

ER ER ER

ERERER

ER ER

ED EDED ED

EDED

EDED

ED ED ED ED

EDEDEDED

ED ED ED ED

ED ED ED ED ED

ED ED

ED

ED ED

ED

EDEDED

ED

ED

ED

ED

EDED

ED

ED

ED

ED

ER

ER

ER

ER

ED

ED

ED

ED

ED

ED

ED

ED

ER

ER

ER

ER ER

ER

ER

ER

ER

ER

ERER

ER ER

ER

ER

ER ER

ER

105 COMMON SPACE

116 PUBLIC PCs115 TECH CLOSET

1S-1 STAIR

1S-2 STAIR

A2-18

A2-32

A2-32

A2-32

A2-32

A2-34

A2-28

A2-28

A2-36

A2-36

A2-26

A2-26

A2-26

A2-26

A2-24

A2-22

A2-22

A2-22

A20-20

A20-20

A2-14

A2-14

A2-21

A2-13

A2-15

A2-17

A2-17

A2-17

A2-17

ED

ER

ED

ED

ED

ED2ED2

ED3

ED3

ED2

ED3

ED2

ED2

ED3

ED2ED3

ED2

ED3

ED2ED2

ED2

ED2

ED3

ED3

ED2ED2

ED3

ED2

ED3

ED3

ED3

ED3ED3

ED3

DEMOLITION DRAWING NOTES

DRAWING IS BASED ON FIELD OBSERVATIONS AND EXISTING DRAWINGS. NOTIFY LEAD CONTRACTOR OF DISCREPANCIES DUE TO ACTUAL FIELD CONDITIONS BEFORE PROCEEDING.

FIXTURES, DEVICES, AND EQUIPMENT DENOTED BY BOLD, DASHED LINE TYPE OR LABELLED BY ED, GENERALLY INDICATES EQUIPMENT TO BE DEMOLISHED. REFER TO DRAWING NOTES AND KEYNOTES FOR FULL EXTENT OF ASSOCIATED DEMOLITION WORK AND ITEMS TO REMAIN. UNLESS OTHERWISE NOTED REMOVE WIRING BACK TO ABOVE FINISHED CEILING. MAINTAIN CIRCUITS FOR CONNECTION TO NEW DEVICES. REFER TO E200 SERIES DRAWINGS.

A.

B.

PROVIDE BLANK COVERS FOR RECESSED BACKBOXES MADE AVAILABLE THROUGH DEMOLITION, UNLESS NOTED FOR REUSE. REFER TO E200 SERIES DRAWINGS.

C.

REFER TO SPECIFICATION SECTION 017419 FOR CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL REQUIREMENTS.

D.

S

TATE OF OHIO

PR

OF

ESSIONAL ENG

INE

ER

JAMES B.MESSNERE-74397

THE ARCHITECT INDICATED ABOVE HAS

BEEN RETAINED SOLEY TO PREPARE

DRAWINGS FROM INFORMATION FURNISHED

BY THE OWNER AND OTHERS FOR THE

PURPOSE OF OBTAINING BUILDING OR

OTHER PERMITS FROM APPROPRIATE

AGENCIES AS REQUIRED BY THE

APPLICABLE BUILDING AND ZONING CODES

OR OTHER REGULATIONS, STATUTES, OR

ORDINANCES

ALL WORK OF THE OWNER OR PERSONS

PERFORMING WORK SHALL CONFORM TO

THE REQUIREMENTS OF ALL CODES, LAWS,

REGULATIONS, ETC. HAVING JURISDICTION

OVER THE WORK.

COPYRIGHTED 2019

ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

7/2

019 7

:21:0

8 A

M

E010

ELECTRICALDEMOLITION

PLAN

12-17-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

3/16" = 1'-0"E010

1 FIRST FLOOR DEMOLITION PLAN

KEYNOTES

ED2 DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURES AND CONTROLS. MAINTAINBRANCH CIRCUIT TO BE REUSED. REFER TO E100 SERIES PLANS

ED3 DISONNECT AND REMOVE EXISTING RECEPTACLES ALONG WITH BRANCH CIRCUIT BACK TOSERVING PANEL. REFER TO E200 SERIES PLANS.

Submittal

jmessner
Signature
jmessner
Text Box
12/17/19
Page 6: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

ER

ER

ER

ER

ER

3 E

R

OS

1

X10

CS1 CS1

OSD OSD CS

1

CS

1C

S1

OS1

X10

X10

CS1

CS1CS1

33

CS

1CS

1

X10

GENERAL LIGHTING NOTES:

A. EXIT SIGNS SHALL BE CONNECTED AHEAD OF ALL SWITCHING. UNLESS OTHERWISE NOTED, EMERGENCY LIGHTING SHALL BE CIRCUIT THROUGH EMERGENCY TRANSFER DEVICE TO ALLOW LOCAL SWITCHING DURING NORMAL POWER. ONCE NORMAL POWER IS LOST, EMERGENCY TRANSFER DEVICE SHALL TURN ON ALL EMERGENCY LIGHTS REGARDLESS OF POSITION OF LOCAL SWITCHING. REFER TO E510 SERIES DRAWINGS FOR DETAIL.

ER

ER ER

ER ER

ER ER

ER ER

ER ER

107 WOMEN

104A STAFF BREAK ROOM

105 COMMON SPACE

106 MEN

112DISCOVERY AREA

114CONSOLE GAMING

100 MAKER WORKSPACE

103 AV LAB

116 PUBLIC PCs

115 TECH CLOSET

108 TEACHING/QUIET LAB

102 STAFF OFFICE 101 WORK ROOM

113 VR LABS

1S-1 STAIR

1S-2 STAIR

ER ER

ERERER

ER ER

ER

ER

ER ER

ER

ER

ERER

ER

ER

ER

ER ER

ER

D20 D20ENL

D20

D10 D10 D10 D10

D10 D10

G20

G20

G20

G20

EX-A2

ER

D20 D20ENL

D20

D10

D10 D10 D10 D10

D10

D10E D10E

D10

D10

D10 D10 D10

D10 D10E D10E D10

D10 D10 D10 D10

D20

D20ENL

D20

D20ENL

D20

A10ENL

A10

A10

A10 A10

A10A10

A10ENL

A10 A10 A10 A10

A10

A10ENL

A10

A10A10

ER

ER

ER

111 YOUTH PCs

110 PUBLIC PCs

109 WORK TABLES

115 COORIDOR

REH

EL1

EL3

EL3

EL1

ER

EL3

EL3

EL3

EL1

D20

EL1

EL3

EL3

EL1

EL1

EL1

EL3

G21G21G21 G21

C10 C10E C10

C10 C10 C10

C10 C10 C10

C10 C10 C10

C10 C10 C10

C10 C10 C10ENL

C10 C10 C10

EL1

EL1

D10

EL3

EL3

A10

EL3

S

TATE OF OHIO

PR

OF

ESSIONAL ENG

INE

ER

JAMES B.MESSNERE-74397

THE ARCHITECT INDICATED ABOVE HAS

BEEN RETAINED SOLEY TO PREPARE

DRAWINGS FROM INFORMATION FURNISHED

BY THE OWNER AND OTHERS FOR THE

PURPOSE OF OBTAINING BUILDING OR

OTHER PERMITS FROM APPROPRIATE

AGENCIES AS REQUIRED BY THE

APPLICABLE BUILDING AND ZONING CODES

OR OTHER REGULATIONS, STATUTES, OR

ORDINANCES

ALL WORK OF THE OWNER OR PERSONS

PERFORMING WORK SHALL CONFORM TO

THE REQUIREMENTS OF ALL CODES, LAWS,

REGULATIONS, ETC. HAVING JURISDICTION

OVER THE WORK.

COPYRIGHTED 2019

ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

7/2

019 7

:21:0

8 A

M

E100

LIGHTINGPLAN

12-17-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

3/16" = 1'-0"E100

1 FIRST FLOOR LIGHTING PLAN

KEYNOTES

EL1 EXTEND EXISTING BRANCH CIRCUIT TO NEW LIGHTING MADE AVAILABLE BYDEMOLITION. WIRE THROUGH NEW LIGHTING CONTROLS. REFER TO DETAILSON SHEET E510.

EL3 CONNECT TO EXISTING EMERGENCY LIGHTING FIXTURE CIRCUIT.

Submittal

jmessner
Signature
jmessner
Text Box
12/17/19
Page 7: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

ER

ER ER

ER

ER

ERER

ER

ER

ER

ER

ER

ER

ER

ER

ER ER

ER

ER

ER

ER

CR CR

CN

C

CN

C

CN

C

GLO

W

TVTV

RE

F

SC

SC

SC

TC

GFI

SC

SC4D

4D

SC4D

SC4D

SC4D

SC4D

SC4D

SC4D

TCTC

PP

LC

2DT

2D

T

PR

TC

2D

2D

2D

2D

PR PR PR2D 2D 2D 2D

2D

ER

EX

. A

7

WH

WH-1

TVTV

2D

TVTV

SC4D

CRCR

2D

2D

CN

CC

NC

GENERAL POWER NOTES:

REFER TO E000 SERIES SHEETS FOR PANEL AND CIRCUIT NUMBERS FOR MECHANICAL AND PLUMBING EQUIPMENT.

A.

REFER TO E000 SERIES SHEETS FOR STARTER AND DISCONNECT REQUIREMENTS FOR MECHANICAL AND PLUMBING EQUIPMENT.

B.

EC SHALL BE RESPONSIBLE TO INSTALL A SWITCH BOX AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING IN EACH ROOM FOR TEMPERATURE CONTROL THERMOSTAT. DEVICES SHOWN ON ELECTRICAL DRAWINGS ARE FOR REFERENCE ONLY. REFER TO THE M SERIES DRAWINGS FOR THERMOSTAT LOCATIONS.

C.

EC SHALL BE RESPONSIBLE FOR TECHNOLOGY ROUGH-IN LOCATIONS. REFER TO T-SERIES DRAWINGS AND SPECIFICATIONS FOR LOCATIONS AND REQUIREMENTS.

D.

ALL NON-LOCKING TYPE, 120V, 15A AND 20A RECEPTACLES THROUGHOUT BUILDING SHALL BE TAMPER-RESISTANT RECEPTACLES.

E.

104 STAFF BREAKROOM

105 COMMON AREA

112DISCOVERY AREA

114CONSOLE GAMING

109 WORK TABLES

100 MAKERWORKSPACE

103 AV LAB

110PUBLIC PCs

116 PUBLIC PCs

115 TECH CLOSET

108 TEACHING/QUIET LAB

115 CORRIDOR

102 STAFF OFFICE

101 WORK ROOM

113VR LABS

1S-1 STAIR

1S-2 STAIR

FB1

FB1

FB1 FB1

FB1 FB1

FB1 FB1

EX-A2

-EX-A2 35

-EX-A2 37

-EX-A2 41

-EX-A2 43

-EX-A2 45

-EX-A2 49-EX-A2 47

-EX-A2 53

-EX-A2 59

-EX-A2 57

-EX-A2 55

-EX-A2 61

FB1

FB2

FB2

FB2

FB2

-EX-A2 32

-EX-A2 20

-EX-A2 36

-EX-A2 24

-EX-A2 14

-EX-A2 22

-EX-A2 26 -EX-A2 28

-EX-A2 67

-EX-A2 50

-EX-A2 52

-EX-A2 58

-EX-A2 56

-EX-A2 54

EP1

EP1

EP1

EP1

EP1

EP1

EP1

EP1

72"

44"44"

44"

-EX-A2 51

-EX-A2 63

-EX-A2 65

EP1

-EX-A2 30

S

TATE OF OHIO

PR

OF

ESSIONAL ENG

INE

ER

JAMES B.MESSNERE-74397

THE ARCHITECT INDICATED ABOVE HAS

BEEN RETAINED SOLEY TO PREPARE

DRAWINGS FROM INFORMATION FURNISHED

BY THE OWNER AND OTHERS FOR THE

PURPOSE OF OBTAINING BUILDING OR

OTHER PERMITS FROM APPROPRIATE

AGENCIES AS REQUIRED BY THE

APPLICABLE BUILDING AND ZONING CODES

OR OTHER REGULATIONS, STATUTES, OR

ORDINANCES

ALL WORK OF THE OWNER OR PERSONS

PERFORMING WORK SHALL CONFORM TO

THE REQUIREMENTS OF ALL CODES, LAWS,

REGULATIONS, ETC. HAVING JURISDICTION

OVER THE WORK.

COPYRIGHTED 2019

ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

7/2

019 7

:21:1

0 A

M

E200

POWERPLAN

12-17-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

3/16" = 1'-0"E200

1 FIRST FLOOR POWER PLAN

KEYNOTES

EP1 PROVIDE UNDERGROUND CONDUITS FOR POWER AND TECHNOLOGYDEVICES FROM ABOVE FINISHED CEILING. PROVIDE (1) 3/4"C FOR POWER,AND (1) 1"C FOR TECHNOLOGY.

Submittal

jmessner
Signature
jmessner
Text Box
12/17/19
Page 8: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

UG

DP-2 1200A, 120/208V, 3PH

1200A

ETR 400A

ETR

UM

T1

ELECTRICAL CALCULATIONS :

TOTAL CALCULATED LOAD (EX-A2) 64.5 kW

179.3A @ 208V, 3PH EXISTING 400A PANEL TO REMAIN

400A

ETR

400A

ETR

150A

ETR

EX-A1

(2) SETS OF (4) #250 AL, #1G

DSW21200A

1200A

(3) SETS OF(4) #500, #3/0G

EX-A2 EX-A3 EX-LC

(4) #1/0 Cu, #6G

(2) SETS OF (4) #250 AL, #1G

(2) SETS OF (4) #250 AL, #1G

LIGHTING CONTROLS

44"

THERMOSTAT

16"

44"

36"

4"

4"

STANDARD POWER OUTLET

ABOVE COUNTER POWER OUTLET

CASE WORK - REFER TO FF-SERIES DRAWINGSCOORDINATE CASEWORK HEIGHT AND BACKSPLASH HEIGHT WITH CASEWORK PROVIDER

ABOVE COUNTER TECHNOLOGY OUTLET

STANDARD TECHNOLOGY OUTLET

88"

WALL MOUNTED FIRE ALARM NOTIFICATION DEVICE

7' -

2" 90"

CLOCK

76"

TV POWER OUTLET

TV TECHNOLOGY OUTLET

84"

TV

8"

44"

4"40

"

CASE WORK - REFER TO FF-SERIES DRAWINGSCOORDINATE CASEWORK HEIGHT AND BACKSPLASH HEIGHT WITH CASEWORK PROVIDER

INTERCOM CALL BUTTON

S

TATE OF OHIO

PR

OF

ESSIONAL ENG

INE

ER

JAMES B.MESSNERE-74397

THE ARCHITECT INDICATED ABOVE HAS

BEEN RETAINED SOLEY TO PREPARE

DRAWINGS FROM INFORMATION FURNISHED

BY THE OWNER AND OTHERS FOR THE

PURPOSE OF OBTAINING BUILDING OR

OTHER PERMITS FROM APPROPRIATE

AGENCIES AS REQUIRED BY THE

APPLICABLE BUILDING AND ZONING CODES

OR OTHER REGULATIONS, STATUTES, OR

ORDINANCES

ALL WORK OF THE OWNER OR PERSONS

PERFORMING WORK SHALL CONFORM TO

THE REQUIREMENTS OF ALL CODES, LAWS,

REGULATIONS, ETC. HAVING JURISDICTION

OVER THE WORK.

COPYRIGHTED 2019

ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

7/2

019 7

:21:1

0 A

M

E400

SCHEDULES& SINGLE

LINEDIAGRAM

12-17-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

EXISTING PANEL

Notes:

Total Est. Demand Current: 178.9 A

Total Conn. Current: 186.6 A

P = PLUMBING EQUIPMENT Total Est. Demand: 64468 VA

M = MECHANICAL EQUIPMENT Total Conn. Load: 67238 VA

R = RECEPTACLES

L = LIGHTS Panel Totals

Total Amps: 202.6 A 173.8 A 187.6 A

Total Load: 24092 VA 20858 VA 22288 VA

83 Spare 20 1 0 0 1 20 Spare 84

81 Spare 20 1 0 0 1 20 Spare 82

79 Spare 20 1 0 0 1 20 Spare 80

77 78

75 76

73 74

71 72

69 70

67 R - CR - ROOM 100 20 1 360 68

65 R - CNC - ROOM 101 20 1 1000 66

63 R - CNC - ROOM 101 20 1 1000 64

61 R - CNC - ROOM 101 20 1 1180 62

59 R - CNC - ROOM 101 20 1 1000 60

57 R - CNC - ROOM 101 20 1 1000 720 1 20 R - FB2 - ROOM 114 58

55 R - GLOW - ROOM 101 20 1 1000 900 1 20 R - FB2 - ROOM 112 56

53 R - REFRIGERATOR GFI 20 1 600 540 1 20 R - FB1 - ROOM 109 54

51 P - WH-1 - 104 20 1 1650 720 1 20 R - TV - ROOM 114 52

49 R - PRINTERS - ROOM 109 20 1 720 1260 1 20 R - 112 AND 113 50

47 R - PRINTERS - ROOM 109 20 1 720 2496 -- -- -- 48

45 R - FB1 - ROOM 110 20 1 720 2496 2 30 EXISTING WATER HEATER 118 46

43 R - FB1 - ROOM 110 20 1 720 2496 -- -- -- 44

41 R - FB1 - ROOM 110 20 1 720 2496 2 30 EXISTING WATER HEATER 117 42

39 Spare 20 1 0 0 -- -- -- 40

37 R - LC - ROOM 108 20 1 600 0 2 30 spare 38

35 R - P, TC - ROOM 108 20 1 540 900 1 20 R - 103 36

33 -- -- -- 2496 0 1 20 Spare 34

31 EXISTING WATER HEATER 135 30 2 2496 900 1 20 R - 104 32

29 -- -- -- 2496 720 1 20 CORDREELS - ROOM 100 30

27 EXISTING WATER HEATER 136 30 2 2496 360 1 20 CORDREELS - ROOM 100 28

25 EXISTING RECEPTACLES 20 1 960 1440 1 20 R - 102 26

23 EXISTING RECEPTACLES 20 1 600 720 1 20 R - 103 24

21 EXISTING RECEPTACLES 20 1 680 720 1 20 R - ROOM 109 22

19 EXISTING RECEPTACLES 20 1 1200 1080 1 20 R - ROOMS 108 AND 110 20

17 EXISTING RECEPTACLES 20 1 1920 1400 1 20 EXISTING RECEPTACLES 18

15 EXISTING RECEPTACLES 20 1 1200 360 1 20 EXISTING RECEPTACLES 16

13 EXISTING RECEPTACLES 20 1 900 1080 1 20 R - FB1 - ROOM 112 14

11 EXISTING RECEPTACLES 20 1 900 0 1 20 SPARE 12

9 EXISTING LIGHTING 20 1 460 1200 1 20 EXISTING LIGHTING 10

7 EXISTING LIGHTING 20 1 840 1680 1 20 EXISTING LIGHTING 8

5 EXISTING LIGHTING 20 1 1200 1320 1 20 EXISTING LIGHTING 6

3 EXISTING LIGHTING 20 1 1380 1200 1 20 EXISTING LIGHTING 4

1 EXISTING LIGHTING 20 1 1080 1200 1 20 EXISTING LIGHTING 2

CKT Circuit DescriptionDeviceNotes Trip Poles A B C Poles Trip

DeviceNotes Circuit Description CKT

Enclosure: MCB Rating:

Mounting: Wall Mounted Wires: 4 Mains Rating: 400.0 A

Supply From: Phases: 3 Mains Type: MLO

Location: Volts: 208Y/120 V A.I.C. Rating: 18,000

Panelboard: EX-A2

E400

1 SINGLE LINE DIAGRAM

E400

2 TYPICAL DEVICE MOUNTING LOCATION

Submittal

jmessner
Signature
jmessner
Text Box
12/17/19
Page 9: TECHNOLOGY CENTER · 2020-01-09 · technology center lane library 228 court st, hamilton, oh 45011 fp100 1/8" = 1'-0" 1 fire protection plan 22-fire protection sheet list sheet number

SEQUENCE OF OPERATION

"ON" MODE (GENERAL ILLUMINATION) WHEN OCCUPANT SELECTS THE "ON" MODE FROM EITHER CONTROL STATION, RELAY PACK(S) SHALL TURN ON ALL FIXTURES.

"OFF" MODE WHEN OCCUPANT SELECTS THE "OFF" MODE FROM EITHER CONTROL STATION, RELAY PACK(S) SHALL TURN OFF ALL FIXTURES.

"DIMMING" MODE ONCE FIXTURES ARE ON, OCCUPANT CAN RAISE/LOWER LIGHTING LEVEL WITH UP/DOWN BUTTONS.

L

LINE VOLTAGE CIRCUIT PER PLAN

(NORMAL) N

LV LV

LV

DIM

L

LINE VOLTAGE CIRCUIT PER PLAN

(EMERGENCY) N

LIGHTING FIXTURE(S)

DIM

N

L

D2

UP

DOWN

CS1CONTROL STATION

ON

OFF

D1

LIGHTING FIXTURE(S)

EMERGENCYN

L

RELAY PACKSINGLE POLE -WITH DIMMING

L1 O1

N

D1 D2

DIM

EMERGENCY TRANSFER

DEVICEETD1 - REFER TO DETAIL 2/E510

LE

L

LN

NE

N

VS

NN

OCCUPANCY SENSOR(S)

D1 D2

DIM

WALL SWITCH

OCCUPANCY SENSORDIMMING

N

DIM

L1 O1L

LINE VOLTAGE CIRCUIT PER PLAN

(NORMAL) N N

L

DIM

LIGHTING FIXTURE(S)

S

TATE OF OHIO

PR

OF

ESSIONAL ENG

INE

ER

JAMES B.MESSNERE-74397

THE ARCHITECT INDICATED ABOVE HAS

BEEN RETAINED SOLEY TO PREPARE

DRAWINGS FROM INFORMATION FURNISHED

BY THE OWNER AND OTHERS FOR THE

PURPOSE OF OBTAINING BUILDING OR

OTHER PERMITS FROM APPROPRIATE

AGENCIES AS REQUIRED BY THE

APPLICABLE BUILDING AND ZONING CODES

OR OTHER REGULATIONS, STATUTES, OR

ORDINANCES

ALL WORK OF THE OWNER OR PERSONS

PERFORMING WORK SHALL CONFORM TO

THE REQUIREMENTS OF ALL CODES, LAWS,

REGULATIONS, ETC. HAVING JURISDICTION

OVER THE WORK.

COPYRIGHTED 2019

ALL RIGHTS RESERVED

DATE

COMM NO

SHEET NO.

12/1

7/2

019 7

:21:1

1 A

M

E510

LIGHTINGDETAILS

12-17-19

2019077.02

TE

CH

NO

LO

GY

CE

NT

ER

LA

NE

LIB

RA

RY

22

8 C

OU

RT

ST

, H

AM

ILT

ON

, O

H 4

50

11

E510

1 CONTROL DETAIL - CONTROL STATION

E510

3 CONTROL DETAIL - WALL SWITCH OSD

Submittal

jmessner
Signature
jmessner
Text Box
12/17/19