technotoy6

54
Technotoy stage 6 DCVG with impressed current switching

Upload: ralexander1938

Post on 13-Apr-2017

22 views

Category:

Engineering


0 download

TRANSCRIPT

Page 1: Technotoy6

Technotoy stage 6

DCVG with impressed current switching

Page 2: Technotoy6

Setting up for stage 6

Page 3: Technotoy6

Cu/CuSO4 electrodes stored.

Page 4: Technotoy6

Power supply to timer

Page 5: Technotoy6

Timer set to 5 sec on 1 sec off

Page 6: Technotoy6

Measurements at 20:35 on 7th July 2016

• Oscilloscope flat line at 1.35 volts

• Left hand meter 1.3552 volts

• Centre meter 448.3 mv• Right hand meter unclear

in picture.• Data logger showing

dynamic graph of DCVG voltages.

• TR set a 3 volts and very little current due to resistances in CP circuit.

Page 7: Technotoy6

DCVG voltages fluctuating.• Corrosion current 46.4

micro-amps being protected during the switched on phase.

• The graphic log of the DCVG voltages are easily seen.

• The left hand meter is measuring the voltage at the blue and green terminals on the breadboard. This is the voltage of the dry cell battery.

Page 8: Technotoy6

In the same minute

• Dry cell battery 1.3551 volts

• Centre meter 484.6mv• Left meter -50.7 micro-

amps corrosion current• Data logger graph visible.• Display response shown

by different voltages through RS232c connection. 482.2 mv.

Page 9: Technotoy6

In the same minute• The electrodes are in the same

positions so the displayed measurements have altered with time

• There are recordings of slight corrosion noise on the oscilloscope.

• The data logger shows the variations in voltages between the two DCVG electrodes during this minute

• The corrosion current has been reversed by the CP and shows negative 52.3 micro-amps

Page 10: Technotoy6

During the next minute

Page 11: Technotoy6

DCVG voltages changing with time

Page 12: Technotoy6

During second minute

Page 13: Technotoy6

During second minute

Page 14: Technotoy6

Immediate after off.

Page 15: Technotoy6

During 3rd minute

Page 16: Technotoy6

During 3rd minute

Page 17: Technotoy6

Showing breadboard circuit

Page 18: Technotoy6

Positions of DCVG electrodes

Page 19: Technotoy6

During 3rd minute

Page 20: Technotoy6

During 4th minute

Page 21: Technotoy6

Corrosion current is negative

Page 22: Technotoy6

Corrosion current is negative.

Page 23: Technotoy6

Corrosion current is positive

Page 24: Technotoy6

Corrosion current is negative

Page 25: Technotoy6

Corrosion current is negative

Page 26: Technotoy6

Corrosion current is negative

Page 27: Technotoy6

Corrosion current is positive.

Page 28: Technotoy6

Corrosion current is positive.

Page 29: Technotoy6

DCVG logged data

Page 30: Technotoy6

Voltage between two electrodes

• This voltage is 000.4 mv when the porous tips are together.

• The values are positive because of the way the probes are plugged into the voltmeter.

• The top graph shows all the values recorded a1 second intervals for 1065 seconds.

• The lower graph shows the first 100 seconds.• Neither graph shows wave forms for the

purposes of determining the ‘polarized potential’.

Page 31: Technotoy6

This stage proves that DCVG cannot possibly determine the corrosion status.

• Remember that we must see a kick on the waveform immediately the CP current is switched off.

Page 32: Technotoy6

DCVG

• Is very good at accurately positioning coating faults.

• It is also good for plotting ground potentials if used properly.

• A copper/copper-sulphate electrode cannot be used as a reference potential to determine if corrosion has been controlled.

Page 33: Technotoy6

Resetting Technotoy

Page 34: Technotoy6

Electrolyte added to Orac

• Two layers of absorbent cloth have been added to the copper plate that represents remote earth.

• Some features have been added between the layers to demonstrate some readings that are often misinterpreted.

Page 35: Technotoy6

Connections

Page 36: Technotoy6

Groundbed and pipelines

• The yellow jumper connect Orac groundbed to the breadboard.

• The black leads seen coming round the front of the case are connected to the pipeline test posts.

Page 37: Technotoy6

Details of breadboard

Page 38: Technotoy6

Details of Orac

Page 39: Technotoy6

Connections to oscilloscope• These are doubled up

with the micro-ammeter.• The anode of the

Alexander cell has been polished to make it react to the electrolyte that will be added to the absorbent cloth.

• The two Cu/CuSO4 electrodes can be seen in their store container.

Page 40: Technotoy6

The Alexander Cell is a corrosion cell in which the corrosion current can be measured

• NACE has not got a method to measure actual corrosion current.

• ICorr has not got a criterion for the achievement of protection or control.

• No university has produced a definitive criterion.

• Using the Alexander Cell in Technotoy we can actually computerize corrosion control.

Page 41: Technotoy6

DCVG measurement record.• The first reading will be

logged at the near zero mv between the tips of the two electrodes.

• The electrodes will then be moved in the same way that DCVG walking sticks are moved during a survey.

• These measurements will be recorded on the data logger in the computer.

Page 42: Technotoy6

Ready to rumble

Page 43: Technotoy6

Start corrosion

• Polish the anode of the Alexander Cell.• Wet the absorbent cloth covering remote

earth on Orac• Switch on the meters and the Oscilloscope• Position the two DCVG probes.• Wet the absorbent ‘bridge’ between the

anode and the cathode on top of the Alexander cell.

Page 44: Technotoy6

Alexander Cell primed and CP ‘On’

Page 45: Technotoy6

DCVG probes same position

Page 46: Technotoy6

CP switching and probes moved• Oscilloscope shows

disturbance plus switching.

• Data logger shows -172.2 volts between the two electrodes.

• Left hand meter 1.3383 volts of battery

• Middle meter -172.4 mv• Left meter -74.6 micro

amps corrosion current reversal.

Page 47: Technotoy6

DCVG probes not moved• Oscilloscope shows

disturbance plus switching.

• Data logger shows -172.2 volts between the two electrodes.

• Left hand meter 1.3383 volts of battery

• Middle meter -172.4 mv• Left meter -74.6 micro

amps corrosion current reversal.

Page 48: Technotoy6

Displayed measurements changed

• Left hand meter 1.3383 volts

• DCVG meter -112.1 volts

• Corrosion current on left hand meter 4.0 micro-amps

Page 49: Technotoy6

Technotoy

Page 50: Technotoy6

Corrosion cell measurement• The DCVG probes placed

on the anode and cathode of the Alexander corrosion cell and displayed 046.7 mv difference.

• Left hand meter 1.3382• DCVG meter 0.428 mv• Protection curent -32.2

micro-amps• 046.7 logged

Page 51: Technotoy6

DCVG probes on corrosion cell

• Left hand meter 1.3382

• DCVG meter 010.9 mv

• Cathodic protection reverse corrosion current on right hand meter.-35.9 micro-amps

Page 52: Technotoy6

Anode corrosion visible.

Page 53: Technotoy6

Visible corrosion

Page 54: Technotoy6

We have demonstrated• It is possible to gather and record data from a

DCVG survey.• This data is not related to the corrosion status of

any structure or pipeline.• We can plot ground potentials in voltages related

to ground potentials at other locations.• A Cu/CuSO4 electrode is a ground contact only.• The electrolyte potential at the interface of

anode in a corrosion cell is the only place that we can make a meaningful measurement for electrochemical calculations.