tecno electric p.m.s. ge.ser.ind. 2012.pdf · 2016. 7. 11. · r.s.p.p.: eng. francesca bertone...

15
Company Profile TECNO ELECTRIC P.M.S. GE.SER.IND.

Upload: others

Post on 07-Mar-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

Company Profile

TECNO ELECTRIC

P.M.S.

GE.SER.IND.

Page 2: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

2

EN ISO 9001:2008 Accredited

SOA Certification n. 7466/05/00 e n. 7467/05/00

EN ISO 9001:2008 Accredited

EN ISO 9001:2008 Accredited

Page 3: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

3

F I E L D S O F A C T I V I T Y

Tecno Electric was established in 1987 as an electrical installation company. Business growth

and development lead to the addition of PMS 1991 as a sister company to cover complimen-

tary activities, while Ge.Ser.Ind. was established in 2002 as an technical/commercial company for the

Management of Business services.

The core activities of companies are:

• Construction of electrical panels of low and medium voltage

• Production and maintenance of installations and electro instrumental

systems

• Electrical Installations

• Data transmission Systems

• Fire and gas detection systems

• Illumination Systems

• Industrial automation

• Production of devices, circuits and mechanisms for the realization of automated

machines and robot ICS

• Security Systems

• Telephone Systems

• CCTV Systems

• Audit Energy

• Photovoltaic Systems

The aim of our group is to provide a service capable of responding

adequately to the needs of various sectors such as:

- PHARMACEUTICAL INDUSTRIES

- CHEMICAL

- PETROCHEMICALS

- FOOD INDUSTRIES

- HOSPITALS

- SCHOOLS

Page 4: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

4

G E N E R A L I N F O R M AT I O N

Structural Factory Data

Occupied Area: 7.740 m2

Covered Area: Office 600 m2

Factory 600 m2

Warehouse 1.280 m2

Human resource

The companies have a total of 175 employers

Manager n° 5

Coordinators n° 14

Software Technicians n° 7

Planning Technicians n° 12

Instrument Technicians n° 8

Administrative employees n° 8

Production Staff n° 121

Annual Turnover (last 4 years)

Year 2008 € 15.258.311

Year 2009 € 16.614.806

Year 2010 € 15.600.916

Year 2011 € 15.792.001

Page 5: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

5

Legal form: Limited Liability Company

Legal and Amm.va: Via Migliara 46, No.20 - 04010 Borgo San Donato - LATINA

Contact: +39 0773/56281 Fax +39 0773/50490

Website / e-mail: www. pmstecnoelectric.it / [email protected]

Share Capital: € 15,600.00

Extraordinary Reserves: € 2,694,199.30

C.F. / P.IVA: 01349730596

Registration Court: n. 13219 Latina of 13/09/1987

Sign C.C.I.A.A.: n. 84456 Latina of 19/10/1987

Sign R.E.C.: n. 37717 Latina of 18/12/1997

Geographical areas of activity: Whole country

SOA:

Cat OG9 - Class III" "Equipment for the production of electricity" "to € 1,032,913.00 "

Cat OG10 - Class IV "Installations for the processing High /Medium Voltage" up to €2,582,284.00

Cat OS5 - Class III "Pneumatics and antrintrusione" up to € 1,032,913.00

Cat OS30 - Class VI "Internal electrical, telephone, radio and television" up to € 10,329,138.00

Type of business: property sales / technical design, project management and execution of:

electrical systems, data transmission systems, telephone systems, CCTV systems, fire detection

and gas, lightning protection systems, photovoltaic systems. Technical Assistance Centre

NOTIFIER.

President of C.d.A.: Ind. Tec. Sergio Panella

Members of the Board: Eng. Alberto D'Ascanio - Mr. Rinaldo Legge

R.S.P.P.: Eng.. Francesca Bertone

Quality System Manager: Dr.. Gabriella Panella

T E C H N I CA L A N D LO G I S T I C S A R E A

The fulcrum of the company, from which the projects and solutions are realized. In this sector

are developed the projects, construction and assembly of panels and

subsequent installations.

E l e c t r i c a l s y s t e m i n s t a l l a t i o n

Typical installations include:

• Standard and Atex approved industrial electrical systems

Page 6: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

6

• Standard and Atex approved control wiring systems

• Telephone systems

• Data cabling

• CCTV systems

• Fire and gas detection systems

• Renewable energy sources

Pro j e ct M a n a g e m e nt

Tecno Electric has developed the design and project engineering side of its business with a

high level of expertize and their qualified staff are members of the appropriate Professional

Associations.

Realizing projects within the following fields:

• Design of electrical installations in accordance with international standards, (CEI,

IEC, UNI, ISO)

• Electrical panel design

• Fire detection systems

• Explosion proof / hazardous atmosphere installations, in line with CEI legislation.

• Installation qualification, planned and unplanned maintenance of :

- Nominal voltage electrical installations, (1000 Vac e 1500 Vdc), ref CEI norms

- Lightning protection systems. (Ref CEI norms)

- Hazardous environments and explosion proof installations.

• Document inspection

• Visual inspections

• Equipment testing in field such as:

- Continuity

- Earth resistance

- Current protection

- Impedance measurement

- Short circuit testing

- MT measurement

- Lighting levels

Page 7: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

7

Legal form: Limited Liability Company

Legal and Amm.va: Via Pontina, km 78600 to 04100 Borgo San Michele - LATINA

Operative Office and Amm.va: Via Migliara 46 No. 20 -04010 Borgo San Donato - LATINA

Contact: +39 0773/50781 Fax +39 0773/50490

Website / e-mail: www. pmstecnoelectric.it / [email protected]

Share Capital: € 15,600.00

C.F. / P.IVA: 01536160599

Registration Court: n. 17627 Latina of 24/05/1991

Sign C.C.I.A.A.: n. 95642 Latina of 23/07/1991

Geographical areas of activity: Whole country

Type of business: Development and consultancy of industrial automation, robotics and mechanical

engineering components. Realization of electro-industrial plants. Building panels. Metrological

Laboratory

Directors: Mr. Giuseppe Panella - Mr. Massimo Panella

R.S.P.P.: Eng. Francesca Bertone

Quality System Manager: Dr. Gabriella Panella

T E C H N I CA L A N D LO G I S T I C S A R E A

P a n e l C o n s t r u c t i o n

The design and construction of both Electrical and Instrument Control panels is an important

and productive department within PMS.

Core business is the production of panels for:

• Low voltage power centers.

• Power and lighting distribution

• Automation and process controls

• Pneumatic and electronic instrumentation control

Page 8: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

8

I n d u s t r i a l A u t o m a t i o n a n d Va l i d ate d s y s t e m s

Another important facet of the business is the generation and development of both

hardware and software for the automation of industrial processes. Innovative application

of technology for reliable standardized results has been achieved through investment in

highly qualified staff, with extensive knowledge of the architecture of DCS / S.C.A.D.A.

systems such as:

• Siemens (PCS7, Totally Integrated Automation “T.I.A”)

• Yokogawa

• Invensys

• Ge Fanuc

• Wonderware

• Allen Bradley

• Omron

• Telemecanique

Our in-house expertise is recognized by our supply partners allowing us to be

• Siemens certified “Solution Partner PCS7”

• Certified, GE Fanuc “VAR”, (Value Added Reseller)

• Andover Controls to T.A.C. / Schneider Electric, certified solution provider.

Validation s e r vices and Instrument

Ca l i b rat i o n/Ce rt i f i cat i o n

The calibration and confirmation of measurement are the requirements for the verification of

the capacity of an instrument to measure.

PMS has developed a quality lab consisting of an Engineer and Instrument technicians

who work with our clients on all aspects of their Qualification, Validation and Calibration

requirements. All works conducted within the department are in line with UNI EN ISO

regulation and guidelines.

In line with our customer requirements PMS has acquired a broad experience and is

continuously expanding its knowledge base of the numerous instruments used within the

pharmaceutical and chemical industries. The team prepare the protocols for validation,

conduct the validation testing in field and produce the validation reports for all phases of the

instrument / equipment qualification:

• Installation Qualification (IQ)

• Operational Qualification (OQ)

• Performance Qualification (PQ) on existing or new machines and equipment

The laboratory also certifies Measurement equipment used in the field by clients and third

parties.

Page 9: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

9

Legal form: Limited Liability Company

Registered Office Via Pontina, km 78,750 to 04100 Borgo San Michele - LATINA

Headquarters: Via Migliara 46, No. 20-04010 Borgo San Donato - LATINA

Contact: +39 0773/252 059 - +39 06/91622069 Fax +39 0773/50490

E-mail: [email protected]

Share Capital: € 10,000.00

C.F. / P.IVA: 02079660599

Sign C.C.I.A.A.: n. 143977 Latina of 21/01/2002

Geographical areas of activity: Whole country

Type of company: Private technical and commercial management of the following industrial services:

Design, installation, operation and maintenance, activities of Energy Management, Project Management,

testing and balancing HVAC systems, Qualification and Revalidations, bio-decontamination, Maintenance

Utilities, process instrumentation and laboratory equipment, development and management of BMS,

environmental monitoring and safety at work.

Chief Mr. Giorgio Di Marco

Responsible technical department: Eng. Claudia Gamba

Project Manager: Eng. Raffaello Giacopetti

R.S.P.P.:Eng. Francesca Bertone

Quality System Manager: Dr. Gabriella Panella

T E C H N I CA L A N D LO G I S T I C S A R E A

Energy Management

Certified Energy Managers

- Completion of a training program organized by AEE (Association of Energy

Engineers)

• Energy Audits

- Conduct audits of energy consumption and identifying savings opportunities

• Best practices and innovative technologies

- Relying on our experience of working with global organizations, we can

indicate possibilities for improvement through the application of "best practices" and, depending

on the

investment capacity of the customer, recommending the introduction of innovative technologies to

reduce

energy consumption

• Alternative Energy

- Design, installation and start-up of solar thermal and photovoltaic systems.

Page 10: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

10

Project Management

• Construction and Renovation Projects

- Preliminary and detailed

• Civil works

• Utilities Design

- HVAC

- Piping

- P & ID

• Furniture and fittings

- Planning of space

- Quantity Surveyors and Tendering

- Monitoring performance of work

• Integrated planning of activities

• Control of changes in the execution phase

- CAD and control documentation

• Lean Six Sigma Methodology

• Development of SOPs (Standard Operating Procedures)

Testing and balancing HVAC systems

• Balance environments

- Dimensional check of the distribution supply and return air.

- Measurement and balancing of airflows Aerodynamic components in the troughs, and the

modules

air handling unit.

- Check the environmental parameters in classified environments.

- Test of integrity of HEPA high efficiency filters.

- Check the air cleanliness class in classified environments.

• Maintenance of Systems

- Replacement filters

- Clean the battery

- Cleaning and sanitizing of UTA and ducts Aerodynamic

- Electrical, mechanical and instrumental

- Calibration and control instrumentation cetificazione

• System commissioning

- Commissioning of plant and machinery for the verification of their optimal operation after

installation.

- Training and information for maintenance personnel on the proper use of the facilities.

• System re-commissioning

- Consultation extended on existing systems to make sure all components are working properly

- Balancing of systems to meet the actual demand and to optimize the operating costs.

Page 11: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

11

Qualifications and Revalidations

• Clean rooms and LAF

- Check the speed and air flow coming out of the high efficiency filters (HEPA)

- Check the pressure drop of high efficiency filters (HEPA)

- Verification of laminar air flow

- Test to verify the integrity of high efficiency filters (HEPA)

- Classification of airborne molecular contamination

- Test of microbiological contamination.

Qualifications and Revalidations

• Fume Hoods

-Test of the front speed according to EN 14175

The speed of the air entering the hood (Face Velocity) is measured using anemometers

accompanied by certificates

issued by SIT centers or equivalent valid. The measurements are performed in accordance with

EN 14175.

Qualifications and Revalidations

• Fume Hoods

-Test of the air velocity in the installation of the fume cupboard according to EN 14175

The purpose of this test is to quantify the flow of air in the immediate vicinity of the fume

cupboard. velocity

above 0.2 m / s can cause reductions in containing cappa.Il test is performed using a

omni-directional anemometer capable of measuring the flows of air present in the proximity of the

hood from the

conditioning system installation room. The sampling points are determined by the EN 14175

according to which the test is conducted

Qualifications and Revalidations

• Fume Hoods

-Visualization of air flow

The purpose of this test is to obtain qualitative information with respect to the flows of air in the

installation area of the hood and

the interaction that the airflow of the hood has with those of the local. The visualization of the flow

occurs through the use of

a visible tracer released at a distance of 400 mm from the front of the hood. Any air movement

near

the opening of the hood is displayed and documented by filming or photographs.

Page 12: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

12

Qualifications and Revalidations

• Fume Hoods

additional Test

- Check the pressure drop (Pressure Drop Test)

- Measuring the pressure at the point of connection of the hood with the extraction system.

Adjustments and Calibrations

Our Company, through the use of instrumentation sample, equipped with certification SIT or

equivalent, is able to perform the calibration and the calibration of electronic instrumentation and

Pneumatic for the main physical quantities such as:

- Pressure

- Temperature

- Humidity

- Speed

- Capacity

- Level

- Electrical Quantities

We are also able to perform:

- Confirmation metrology for process instrumentation in the chemical and pharmaceutical industry

- Mapping of temica:

ovens

autoclaves

Rooms and cabins thermostated

dryers

crystallizers

- Relizzazione and drafting of protocols IQ, OQ and PQ

Page 13: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

13

A D M I N I S T RAT I V E A R E A

Directed and coordinated by the President of the board of directors overseeing the commer-

cial and managerial activities of the firm:

- Commercial Department

- Training Center

C o m m e rc i a l D e p a rt m e nt

The commercial department of Tecno Electric was created in 1997 with the inscription to

R.E.C. of C.C.I.A. of Latina N° 37717. Its scope to sell wholesale materials connected to the

electrical sector providing a complete service to both the internal company and external

customers.

Sales Categories:

• Electrical Materials

• White goods

• Mechanical instruments, machines and equipment

• Trade products

• Others

Tr a i n i n g C e nt e r

Tecno Electric, PMS and Ge.Ser.Ind. strive to maintain their level of excellence in all the fields

that they work within. To this end there is a dedicated training room for training both internal

staff and external participants. The room can accommodate up to 50 people and is used for

specific courses and meetings.

Courses conducted by supply partners include:-

• Siemens

• ABB

• Schneider

• Dehn

• Pepperl & Fuchs

Page 14: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

14

C U R R E N T C L I E N T B A S E

Abbott S.p.A

A.C.R.A.F. S.p.A

Alpla Italia S.p.A.

Advent S.r.l.

Banca d’Italia

Basf Italia S.r.l.

Biomendica Foscana S.p.A.

Birra Peroni S.p.A.

Bristol-Myers Squibb S.r.l.

BSP Pharmaceuticals S.r.l.

Catalent Italy S.p.A.

CharlesRiverLaboratories Italia S.r.l.

Chemi S.p.A.

Chemtura Italy S.r.l.

Chem

Classcon S.r.l.

Colgate Palmolive Italia S.r.l.

C.S.V. S.p.A.

DP Lubrificannti S.r.l.

Istituto Biochimico Italiano S.p.A.

I.R.B.M. S.p.A.

Johnson Control System & Service Italy S.p.A.

Janssen Cilag S.p.A.

Heinz Italia S.p.A

Labozeta S.p.A.

Menarini Biotech S.r.l.

Merck Serono S.p.A.

Merck-Sharp-Dhome S.p.A.

Nalco Italiana S.r.l.

Nestlè Italiana S.p.A.

Patheon Italia S.p.A.

Pietro Fiorentini S.p.A.

R.T.C. S.p.A.

Sanofi Aventis S.p.A.

Le Petit S.r.l.

Sammontana S.p.A.

Sicamb S.p.A.

Schneider Electric S.p.A..

Sodexo Italia S.p.A.

Sigma Tau S.p.A.

Tubilux Pharma S.r.l.

Viscolube S.p.A.

Wyeth Lederle S.p.A.

Page 15: TECNO ELECTRIC P.M.S. GE.SER.IND. 2012.pdf · 2016. 7. 11. · R.S.P.P.: Eng. Francesca Bertone Quality System Manager: Dr. Gabriella Panella TECHNICAL AND LOGISTICS AREA Panel Construction

Tecno Electric S.r.l.

Registered Office: Via Migliara 46, n.20

04010 - B.go S.Donato (LT)

Contacts: Tel. +039 0773 5628.1 - Fax +039 0773 50490

P.M.S. S.r.l.

Registered Office: S.S. 148 Pontina Km. 78,600

04010 - Borgo San Michele (LT)

Factory: Via Migliara 46, n.20

04010 - B.go S.Donato (LT)

Contacts: Tel. +039 0773 50781 - Fax +039 0773 50490

Ge.Ser. Ind. S.. r. l.

Registered Office: S.S. 148 Pontina Km. 78,750

04010 - Borgo San Michele (LT)

Factory: Via Migliara 46, n.20

04010 - B.go S.Donato (LT)