RCB-1.3 TESTING RCB-1.31 STANDARD TEST The exchanger shall be hydrostatically tested with water. The test pressure shall be held for at least 30 minutes. The shell side and the tube side are to be tested separately in such a manner that leaks at the tube joints can be detected from at least one side. When the tube side design pressure is the higher pressure, the tube bundle shall be tested outside of the shell only if specified by the purchaser and the construction permits. Welded joints are to be sufficiently cleaned prior to testing the exchanger to permit proper inspection during the test. The minimum hydrostatic test pressure at room temperature shall be in accordance with the Code.

Upload: aminiaan

Post on 07-Sep-2015

569 views

Category:

Documents


16 download

DESCRIPTION

TEMA-Hydrotes Procedure

TRANSCRIPT

RCB-1.3 TESTINGRCB-1.31 STANDARD TESTThe exchanger shall be hydrostatically tested with water. The test pressure shall be held for at least 30 minutes. The shell side and the tube side are to be tested separately in such a manner that leaks at the tube joints can be detected from at least one side. When the tube side design pressure is the higher pressure, the tube bundle shall be tested outside of the shell only if specified by the purchaser and the construction permits. Welded joints areto be sufficiently cleaned prior to testing the exchanger to permit proper inspection during the test. The minimum hydrostatic test pressure at room temperature shall be in accordance with the Code.