Page 1: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must
Page 2: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

TERMINAL LEARNING OBJECTIVE

ACTION: Perform COFT Operations

CONDITION: Given a COFT, COFT IUH, and in a classroom environment

STANDARDS: I/O student must demonstrate knowledge of proper COFT training by achieving 80% or higher on the I/O end of course exam and achieve an overall “GO” on all hands on test

Page 3: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

COFT SAFETY BRIEFING

SAFETY:

• Tampering with equipment is prohibited and horseplay will not be tolerated

• CVC helmets must be worn in the Crew Station at all times

• No food, drinks, smoking or smokeless tobacco are allowed in the training area

• Use all required references during maintenance and training

• Do not walk on or move any cables, or touch any electrical connections

Page 4: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

COFT SAFETY BRIEFING (Con’t)

• Know the location and function of the three Emergency Shutdown Switches

• Know where the fire extinguishers are, how to use them, the location of emergency exits and the Shelter Emergency Shutdown Switches

• Observe all CAUTION and WARNING labels throughout the trainer

• Do not permit any activity in the COFT that is unsafe in the BFV

Page 5: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Risk Assessment Level: Moderate, due to potential for exposed high voltage cables

Environmental Considerations: None

Evaluation: I/O student must demonstrate knowledge of proper COFT training by achieving 80% or higher on the I/O end of course exam and achieve an overall “GO” on all hands on test

Page 6: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

ENABLING LEARNING OBJECTIVE A

ACTION: Identify COFT Components and Characteristics

CONDITION: Given a COFT, COFT IUH, and classroom instruction

STANDARDS: Student must adhere to policies and procedures throughout entire I/O course

Page 7: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

• Crew Station

• Instructor/Operator Station (IOS)

• Computer Rack

MAJOR COMPONENTS

Page 8: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

CREW STATION

Page 9: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

INSTRUCTOR OPERATOR STATION (IOS)

Page 10: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

COMPUTER RACK

The computer rack consists of the following components:

PrinterModSAF ComputerIOS ComputerIG1 ComputerIG2 ComputerBVE ComputerKVM Switcher

Page 11: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

ENABLING LEARNING OBJECTIVE B

ACTION: Perform COFT Power Up

CONDITION: Given a COFT, COFT IUH, and in a classroom environment

STANDARDS: Successfully power up the COFT IAW with IUH

Page 12: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

Shelter Preconditioning Procedures

Shelter Door Vent

Fire Protection Panel

Shelter Lighting SwitchesEmergency Light

Page 13: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

Shelter Preconditioning Procedures

Door Locking Pin

Air Conditioner Louvers

Hygrometer/Thermometer

Observe the hygrometer/thermometer in the Training Shelter. If the temperature reading is between 60º F and 90ºF (15ºC and 30ºC) and relative humidity is between 20 and 70 percent, refer to (ADD TM #), Unusual Electronic Equipment Power-Up Procedure

Page 14: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

A/C Mode Selector

Shelter A/C Mode Selector Switch Setting

Outside Temperatur

e Ranges

ComputerShelter

TrainerShelter

IntecShelter

51AC1 51AC2 51AC3 52AC1 53AC1

-40ºF to -5ºF-40ºC to -20ºC

Vent Heat Cool Heat Heat

-5ºF to 20ºF-20ºC to 6.7ºC

Vent Heat Cool Cool Heat

20ºF to 68ºF-6.7ºC to 20ºC

Cool Vent Cool Cool Heat

68ºF to 80ºF20ºC to 26.7ºC

Cool Vent Cool Cool Cool

80ºF to 125ºF26.7ºC - 51.7ºC

Cool Cool Cool Cool Cool

Humidifier Tank Water Level Gage

Page 15: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

Main Circuit Breaker

Circuit Breakers 2 and 6

Page 16: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

Main Power 208VAC

MainCircuit Breaker

AC ON Lamp

Page 17: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

Key-switch AC ON Lamp

Once the key-switch is turned on, wait until the monitor displays the System Startup screen before continuing

Page 18: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

System Start Up

Page 19: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

Crew StationAuxiliary Equipment

AC ON Lamps

DC Power Lamps

Page 20: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

AC ON Lamp

Crew Station (CFP/ISUW)

Page 21: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Up Procedure

AC ON Lamp

AC ON Lamp

Intercom & Test equipment

Crew Compartment Power

Brow Pad

Page 22: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

System Start Up

Page 23: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

System Start Up

Page 24: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

ENABLING LEARNING OBJECTIVE C

ACTION: Manage COFT Time Logbook

CONDITION: Given a COFT, COFT IUH, and in a classroom environment

STANDARDS: Manage system logbook in accordance with IUH TM 9-6930-712-12

Page 25: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

COFT TIME LOGBOOK

SIGNATURE

Ernie Lindquist

Ernie Lindquist

Brad Tesch (FSR)

Ernie Lindquist

Ernie Lindquist

Ernie LindquistBrad Tesch (FSR)

Ernie Lindquist

Ernie Lindquist

MIN

30

ACCOUNTABLEFAILURE TIME

HRS

3

5

BLDG 5500LOCATION: Fort Benning

ETM

123.1

128.3

128.3

140.5

140.5

142.3

142.3

152.1

SERIAL NO. 4962

REMARKS

Power up

Power down

Power up

WCB: HE ammo would not selectNotified FSR

Replaced ammo selection switch

Power down

Power upCTD power went down

Notified FSR

Power up

Power down

TIME (00:00)

14:00

19:00

06:00

18:25

11:25

17:00

03:00

09:30

15:00

23:00

COFT SYSTEM LOGDAILY OPERATIONS

DATE(MMDDYY)

01/05/03

01/05/03

01/06/03

01/06/03

01/06/03

01/06/03

01/07/03

01/07/03

01/07/03

01/07/03

DA FORM XXX-A-R

Page 26: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

ENABLING LEARNING OBJECTIVE D

ACTION: Perform Instructor Login and Log Off

CONDITION: Given a COFT, COFT IUH, and in a classroom environment

STANDARDS: Successfully perform COFT Instructor Login and Log Off procedures in IAW, IUH TM 9-6930-712-12

Page 27: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

System Login

Page 28: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

2/8IN A11

INSTRUCTOR LOG OFF

Log Off

Page 29: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

ENABLING LEARNING OBJECTIVE E

ACTION: Perform COFT Power-down

CONDITION: Given a COFT, COFT IUH, and in a classroom environment

STANDARDS: Successfully Power-down the COFT, in sequence and in accordance with IUH TM 9-6930-712-12

Page 30: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Down Procedure

Quit

Page 31: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Down Procedure

Viewgraph J-17

Page 32: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Down Procedure

Ensure Power Lamps go off

Last computer Lamp remains on

Page 33: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

Power Down Procedure

Main Circuit BreakerCrew Station (CFP/ISUW)

Key-switch

Crew StationAuxiliary Equipment)

Page 34: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

TERMINAL LEARNING OBJECTIVE

ACTION: Perform COFT Operations

CONDITION: Given a COFT, COFT IUH, and in a classroom environment

STANDARDS: I/O student must demonstrate knowledge of proper COFT training by achieving 80% or higher on the I/O end of course exam and achieve an overall “GO” on all hands on test

Page 35: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must

SUMMARY

ELO A: Identify COFT Components and Characteristics

ELO B: Perform COFT Power-up

ELO C: Manage COFT Time Logbook

ELO D: Perform Instructor Logoff

ELO E: Perform COFT Power-down