test report issued under the responsibility offtp3.thecus.com/download/other/adapter...
TRANSCRIPT
Test Report issued under the responsibility of:
TEST REPORT
IEC 60950-1 Information technology equipment – Safety –
Part 1: General requirements Report Number. .............................. : 15057193 003
Date of issue..................................... : 2013-03-25
Total number of pages ...................... 13
CB Testing Laboratory ................... : TÜV Rheinland (Shanghai) Co., Ltd.
Address ............................................ : B1-13/F, No.177, Lane 777, West Guangzhong Road, Zhabei District, Shanghai 200072, P.R. China
Applicant’s name ............................ : Channel Well Technology Co., Ltd.
Address ............................................ : No.222, Sec. 2, Nankan Rd., Lujhu Township, Taoyuan Hsien, 33855 Taiwan
Manufacturer’s name……………….: Same as applicant
Address ............................................ : Same as applicant
Test specification:
Standard ........................................... : IEC 60950-1:2005 (Second Edition) + Am 1:2009
Test procedure ................................. : CB Scheme
Non-standard test method…………..: N/A
Test Report Form No. ..................... : IEC60950_1C
Test Report Form(s) Originator ........ : SGS Fimko Ltd
Master TRF....................................... : Dated 2012-08
Copyright © 2012 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .....................: AC ADAPTER
Trade Mark ....................................... :
Manufacturer .................................... : Same as applicant
Model/Type reference ...................... : KPL-xy (x can be 040, 050, 060 or 065, denotes for output power; y can be F, G, V, H, I, W, J, K, L, N, Q, R or M, denotes for output voltage)
Ratings ............................................. : Refer to report No. 15057193 001
Page 2 of 13 Report No. 15057193 003
TRF No. IEC60950_1C
Testing procedure and testing location:
CB Testing Laboratory: TÜV Rheinland (Shanghai) Co., Ltd.
Testing location/ address ........................... : B1-13/F, No.177, Lane 777, West Guangzhong Road, Zhabei District, Shanghai 200072, P.R. China
Associated CB Laboratory:
Testing location/ address ........................... :
Tested by (name + signature) .......... : Tobias Yang
Approved by (name + signature) ...... : Mark Chen
Testing procedure: TMP
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature) ...... :
Testing procedure: WMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Witnessed by (name + signature) .... :
Approved by (name + signature) ...... :
Testing procedure: SMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature) ...... :
Supervised by (name + signature) ... :
Testing procedure: RMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature) ...... :
Supervised by (name + signature) ... :
Page 3 of 13 Report No. 15057193 003
TRF No. IEC60950_1C
List of Attachments (including a total number of pages in each attachment):
N/A
Summary of testing:
Tests performed (name of test and test clause):
• N/A
Testing location:
All tests as described in Test Case and Measurement Sections were performed at the laboratory described on page 2.
Summary of compliance with National Differences
List of countries addressed:
EU Group Differences, EU Special National Conditions, FI, DE, DK, IL, KR, SI, SE, GB, AU, CA, CH, ES, IE, NO, US
Explanation of used codes:
AU=Australia, CA=Canada, CH=Switzerland, DE=Germany, DK=Denmark, FI=Finland, GB=United Kingdom, IE=Ireland, IL = Israel, KR=Korea, NO=Norway, SE=Sweden, ES=Spain, US=United States of America.
The product fulfils the requirements of EN 60950-1:2006+A11:2009+A1:2010+A12:2011
Page 4 of 13 Report No. 15057193 003
TRF No. IEC60950_1C
Copy of marking plate
N/A
Page 5 of 13 Report No. 15057193 003
TRF No. IEC60950_1C
Test item particulars .................................................. :
Equipment mobility .................................................... : [x] movable [] hand-held [x] transportable [] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................ : [x] pluggable equipment [x] type A [] type B [] permanent connection [x] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains
Operating condition ................................................... : [x] continuous [] rated operating / resting time:
Access location ......................................................... : [x] operator accessible [] restricted access location
Over voltage category (OVC) ................................... : [] OVC I [x] OVC II [] OVC III [] OVC IV [] other:
Mains supply tolerance (%) or absolute mains supply values ....................................................................... :
± 10%
Tested for IT power systems .................................... : [x] Yes [] No
IT testing, phase-phase voltage (V) ......................... : For Norway, 230V
Class of equipment ................................................... : [x] Class I [] Class II [] Class III [] Not classified
Considered current rating of protective device as part of the building installation (A) ............................ :
Pollution degree (PD) ............................................... : [] PD 1 [x] PD 2 [] PD 3
IP protection class .................................................... : IPX0
Altitude during operation (m) .................................... : Up to 2000
Altitude of test laboratory (m) ................................... : < 2000
Mass of equipment (kg) ............................................ : Approx. 0.24 kg for output power 40-50W models. Approx. 0.26 kg for output power 60-65W models except for model KPL-065F. Approx. 0.27 kg for model KPL-065F.
Possible test case verdicts:
- test case does not apply to the test object ................. : N/A (or N)
- test object does meet the requirement ....................... : P (Pass)
- test object does not meet the requirement ................. : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ............................................ : N/A
Date(s) of performance of tests .................................... : N/A
General remarks:
Page 6 of 13 Report No. 15057193 003
TRF No. IEC60950_1C
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ................................................................ :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) ........................... : 1) Ningbo Iso Electronic Co., Ltd. 10, Chuange-ye Rd., The West of Ningbo Free Trade Zone, Ningbo, Zhejiang, P.R. China
2) Channel Well Technology (Guangzhou) Co., Ltd. Bld. B, Eastern Hi-tech Industrial Base, Zengjiang Street, Zengcheng, Guangzhou, Guangdong 511300, P.R. China
General product information:
Description of change(s):
1. Add alternative source of varistor as below: - Mfg: Thinking Electronic Industrial Co., Ltd.; Typ: TVR14681 - Mfg: Nanjing Jocol Electronics Technology Co., Ltd.; Typ:TUR14D681K
2. Correct typing error on technical data of varistor
3. Name the unspecified components as “interchangeable” components
For the above described change(s) the following was considered to be necessary:
Change Testing Comments
1. N/A Approved components, higher ratings used. See appended table 1.5.1 in bold for details.
2. N/A See appended table 1.5.1 in bold for details.
3. N/A See appended table 1.5.1 in bold for details.
Definition of variable(s): KPL-xy
Variable: Range of variable: Content:
x Can be 040, 050, 060 or 065
Denotes for output power. 040 = 40W, 050 = 50W, 060 = 60W, 065 = 65W.
y Can be F, G, V, H, I, W, J, K, L, N, Q, R or M
Denotes for output voltage. F = 12V, G = 13V, V = 14V, H = 15V, I = 16V, W = 17V, J = 18V, K = 19V, L = 20V, N =
Page 7 of 13 Report No. 15057193 003
TRF No. IEC60950_1C
21V, Q = 22V, R = 23V, M = 24V.
History of amendments and modifications: Ref. No. 15057193 001, dated 19.12.2012 Ref. No. 15057193 002, dated 05.03.2013 Ref. No. 15057193 003, dated 25.03.2013
Abbreviations used in the report:
- normal conditions N.C. - single fault conditions S.F.C - functional insulation OP - basic insulation BI - double insulation DI - supplementary insulation SI - between parts of opposite polarity BOP - reinforced insulation RI Indicate used abbreviations (if any)
Page 8 of 13 Report No. 15057193 003
IEC 60950-1/Am1
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60950_1C
1.5.1 TABLE: List of critical components P
Object/part no. Manufacturer/ trademark
Type/model Technical data Standard Mark(s) of conformity 1.
Plastic Enclosure
SABIC Innovative Plastics Japan L L C
SE1X V-1 or better, 105°C, thickness 1.5 mm min.
UL 94 UL
<Alternative> Teijin Chemicals Plastic Compounds Shanghai Ltd
LN-1250G V-0 or better, 115°C, thickness 1.5 mm min.
UL 94 UL
PCB Interchangeable Interchangeable V-1 or better, min. 130°C
UL 94, UL 796 UL
Appliance Inlet (CON1)
Tecx-Unions Technology Corporation.
TU-301-SP 10 A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Tecx-Unions Technology Corporation.
TU-333 2.5 A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Rong Feng Industrial Co., Ltd.
RF-190 2.5 A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Rong Feng Industrial Co., Ltd.
SS-120 10A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Rich Bay Co., Ltd. R-30790 2.5A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Rich Bay Co., Ltd. R-301SN 10A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Zhe Jiang Bei Er Jia Electronic Co., Ltd.
ST-A01-003J 10A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Zhe Jiang Bei Er Jia Electronic Co., Ltd.
ST-A04-002 2.5A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Supercom Electronics Co., Ltd.
SC-8R 10A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
<Alternative> Supercom Electronics Co., Ltd.
SC-14 2.5A, 250 Vac, 70°C
IEC/EN 60320-1+A1, ANSI/UL 498
VDE, UL
Page 9 of 13 Report No. 15057193 003
IEC 60950-1/Am1
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60950_1C
Fuse (Fuse1) XC Electronics (Shenzhen) Corp. Ltd.
4T T4.0AL, 250 Vac
IEC/EN 60127-1, IEC/EN 60127-3, ANSI/UL 248-1, ANSI/UL 248-14
VDE, UL
<Alternative> XC Electronics (Shenzhen) Corp. Ltd.
5TE T4.0AL, 250 Vac
IEC/EN 60127-1, IEC/EN 60127-3, ANSI/UL 248-1, ANSI/UL 248-14
VDE, UL
<Alternative> Ever Island Electric Co., Ltd. and Walter Electric
2010 T4.0AL, 250 Vac
IEC/EN 60127-1, IEC/EN 60127-3, ANSI/UL 248-1, ANSI/UL 248-14
VDE, UL
<Alternative> Conquer Electronics Co., Ltd.
PTU T4.0AL, 250 Vac
IEC/EN 60127-1, IEC/EN 60127-3, ANSI/UL 248-1, ANSI/UL 248-14
VDE, UL
<Alternative> Conquer Electronics Co., Ltd.
MST T4.0AL, 250 Vac
IEC/EN 60127-1, IEC/EN 60127-3, ANSI/UL 248-1, ANSI/UL 248-14
VDE, UL
<Alternative> Littelfuse, Inc. Wickmann- Werke
392 T4.0AL, 250 Vac
IEC/EN 60127-1, IEC/EN 60127-3, ANSI/UL 248-1, ANSI/UL 248-14
VDE, UL
Varistor (TVS1) (after fuse and not connected to PE)) (Optional)
Thinking Electronic Industrial Co., Ltd.
TVR14471 300Vac/385Vdc, Max 4500A, 85°C
IEC 61051-1, IEC 61051-2, IEC 61051-2-2, ANSI/UL 1449 3rd, Annex Q of IEC 60950-1
VDE, UL
<Alternative> Thinking Electronic Industrial Co., Ltd.
TVR14681 420Vac/560Vdc, Max 4500A, 85°C
IEC 61051-1, IEC 61051-2, IEC 61051-2-2, ANSI/UL 1449 3
rd, Annex Q of
IEC 60950-1
VDE, UL
<Alternative> Nanjing Jocol Electronics Technology Co., Ltd.
TUR14D471K 300Vac/385Vdc, Max 4500A, 85°C
IEC 61051-1, IEC 61051-2, IEC 61051-2-2, ANSI/UL 1449 3rd, Annex Q of IEC 60950-1
TUV, UL
Page 10 of 13 Report No. 15057193 003
IEC 60950-1/Am1
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60950_1C
<Alternative> Nanjing Jocol Electronics Technology Co., Ltd.
TUR14D681K 420Vac/560Vdc, Max 4500A, 85°C
IEC 61051-1, IEC 61051-2, IEC 61051-2-2, ANSI/UL 1449 3
rd, Annex Q of
IEC 60950-1
TUV, UL
X-Capacitor (CX1) (X1 or X2 type) (Optional)
Okaya Electric Industries Co., Ltd.
LE Max. 0.47 µF, min. 250 Vac, 100°C
IEC/EN 60384-14: 2005, UL 1414
ENEC, UL
<Alternative> Jenn Fu Electronics Corporation
MPX Max. 0.47 µF, min. 250 Vac, 100°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
<Alternative> Europtronic (Taiwan) Ind. Corp.
MPX2 Max. 0.47 µF, min. 250 Vac, 110°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
<Alternative> Ultra Tech Xiphi Enterprise Co., Ltd.
HQX Max. 0.47 µF, min. 250 Vac, 100°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
<Alternative> Hua Jung Components Co., Ltd.
MKP Max. 0.47 µF, min. 250 Vac, 100°C
IEC/EN 60384-14: 2005, UL 1414
ENEC, UL
<Alternative> Arcotronics Italia S.P.A
R.46 Max. 0.47 µF, min. 250 Vac, 100°C
IEC/EN 60384-14: 2005, UL 1414
ENEC, UL
Bleeder Resistor (R2, R3, R4, R5)
Interchangeable Interchangeable SMD type, 2.2 MΩ, 1/4 W, Four in series after fuse
IEC/EN 60950-1 Test within the unit
Bridging Capacitor (CY1) (Y1 type) (Optional)
TDK Corporation CD Max. 2200 pF, min. 250 Vac, 125°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
<Alternative> Murata Mfg. Co., Ltd.
KX Max. 2200 pF, min. 250 Vac, 125°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
<Alternative> Walsin Technology Corp.,
AH Max. 2200 pF, min. 250 Vac, 125°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
<Alternative> JYA-NAY Co., Ltd.
JN Max. 2200 pF, min. 250 Vac, 125°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
<Alternative> Success Electronics Co., Ltd.
SB, SE Max. 2200 pF, min. 250 Vac, 125°C
IEC/EN 60384-14: 2005, UL 1414
VDE, UL
Page 11 of 13 Report No. 15057193 003
IEC 60950-1/Am1
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60950_1C
Bridge Diode (BD1)
Interchangeable Interchangeable Min. 2 A, min. 600 V
-- Test within the unit
Ripple Capacitor (C2)
Interchangeable Interchangeable 68-120 µF, min. 400 V, min. 105°C
-- Test within the unit
Transistor (Q1) Interchangeable Interchangeable Min. 4.5 A, min. 600 V
-- Test within the unit
Current Sensor Resistor (R9, R15, R16, R18, R23)
Interchangeable Interchangeable Min. 1.8 Ω, min. 1/4 W, SMD type
-- Test within the unit
Line Choke (LF1) (Optional)
Sunycore Electronics Co., Ltd.
T18*10*7 130°C -- Test within the unit
<Alternative> Channel Well Technology Co., Ltd.
T18*10*7 130°C -- Test within the unit
Line Choke (LF2) (Optional)
Sunycore Electronics Co., Ltd.
T10*6*5+C 130°C -- Test within the unit
<Alternative> Channel Well Technology Co., Ltd.
T10*6*5+C 130°C -- Test within the unit
Transformer (T1)
(for output voltage 12-16V used)
Channel Well Technology Co., Ltd.
PQ-2620-12 Class B (GH-130)
Applicable parts of IEC 60950-1 and according to IEC 60085
Accepted by TÜV Rheinland
(for output voltage 17-24V used)
Channel Well Technology Co., Ltd.
PQ-2620-17 Class B (GH-130)
Applicable parts of IEC 60950-1 and according to IEC 60085
Accepted by TÜV Rheinland
Bobbin (for T1) Chang Chun Palstics Co., Ltd.
T375J Phenolics, 150°C, V-0
UL 94 UL
Triple insulated wire (for T1 secondary winding)
Great Leoflon Industrial Co., Ltd.
TRW(B) 130°C IEC/EN 60950-1, UL 2353
VDE, UL
Sleeving (for T1)
Great Holding Industrial Co., Ltd.
TFL 200°C, VW-1 UL 224 UL
Page 12 of 13 Report No. 15057193 003
IEC 60950-1/Am1
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60950_1C
Optocoupler (IC1)
Lite-On Technology Corporation
LTV-817 Dti ≥ 0.4 mm, Int. cr > 4.0 mm, Ext. cr = 8.0 mm, 110°C
DIN EN 60747-5-2, IEC/EN 60950-1, UL 1577
VDE, Fimko, UL
<Alternative> Cosmo Electronics Corporation
K1010 Dti = 0.5 mm, Int. cr = 5.3 mm, Ext. cr = 8.0 mm, 110°C
DIN EN 60747-5-2, IEC/EN 60950-1, UL 1577
VDE, Fimko, UL
<Alternative> Toshib Corp. Semiconductor
TLP781/TL781F Dti = 0.5 mm, Int. cr = 6.0 mm, Ext. cr = 7.7 mm, 110°C
DIN EN 60747-5-2, IEC/EN 60950-1, UL 1577
VDE, Fimko, UL
<Alternative> Everlight Electronics Co Ltd
EL817 Dti = 0.5 mm, Int. cr = 6.0 mm, Ext. cr = 7.7 mm, 110°C
DIN EN 60747-5-2, IEC/EN 60950-1, UL 1577
VDE, Fimko, UL
<Alternative> Fairchild Semiconductor
FOD817 Dti ≥ 0.4 mm, Int. cr ≥ 5.0 mm, Ext. cr ≥ 7.0 mm, 110°C
DIN EN 60747-5-2, IEC/EN 60950-1, UL 1577
VDE, Fimko, UL
Insulator sheet ITW Electronics Components/Products (Shanghai) Co., Ltd.
FORMEX GK-17 V-1 or better, thickness 0.43 mm min.
UL 510 UL
<Alternative> YI-HSN Plastech Co Ltd.
YIMEX PP-17 V-1 or better, thickness 0.43 mm min.
UL 510 UL
Output cable Interchangeable Interchangeable 16 or 18AWG, 300V, 80°C, FEP, PTFE, PVC, TFE, neoprene, polyimide or marked VW-1
UL 758 UL
Thermal pad for C2 (for 60W and 65W models)
Interchangeable Interchangeable V-2 or better UL 94 UL
Rubber pad (under PCB)
Interchangeable Interchangeable V-2 or better UL 94 UL
Page 13 of 13 Report No. 15057193 003
IEC 60950-1/Am1
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60950_1C
Supplementary information:
1. An asterisk indicates a mark that assures the agreed level of surveillance.
2. In Optocoupler technical data column, where “di” means distance through insulation, “int.” means internal creepage distance, “ext.” means external creepage distance.
- End of Test Report-