test report n° 121264 - omp groupconfigurator.ompchairs.com/files/2012/01/1326703534.pdf · the...

13
Date received: 05-10-10 Date of issue: 25-11-10 Report consists of 10 attached sheets. Sample name: SHINY TEST REPORT N° 121264 List performed tests 1. Office work chair: dimensions EN 1335-1:2000 AC:2002 2. General design requirements EN 1335-2:2009, clause 4.1 3. Seat and back static load test 1335-3:2009 AC:2009, clause 7.2.1-7.2.2 4. Seat and back durability - EN 1335-3:2009 AC:2009 - Clause 7.3.1 5. Arm rests durability EN 1335-3:2009 AC:2009, clause 7.3.2 6. Arm rest downward static load test-central EN 1335-3:2009 AC:2009, clause 7.2.3 7. Stability EN 1335-3:2009 AC:2009, clause 7.1 8. Arm rest downward static load test - front EN 1335-3:2009 AC:2009, clause 7.2.4 9. Arm rest sideways static load test EN 1335-3:2009 AC:2009, clause 7.2.5 10. Swivel test EN 1335-3:2009 AC:2009, clause 7.3.3 OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer. CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v. Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected] Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected] centro ricerche-sviluppo laboratorio prove settore legno-arredo Page 1 of 2 This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems. Managing Director Dr. Andrea Giavon Defects before testing: None Overall dimensions: 750 x 750 x 1060 (h) mm (extended uncertainty = 5 mm)

Upload: dinhmien

Post on 17-Feb-2019

214 views

Category:

Documents


0 download

TRANSCRIPT

Date received: 05-10-10

Date of issue: 25-11-10

Report consists of 10 attached sheets.

Sample name: SHINY

TEST REPORT N° 121264

List performed tests

1. Office work chair: dimensions EN 1335-1:2000 AC:2002 2. General design requirements EN 1335-2:2009, clause 4.1 3. Seat and back static load test 1335-3:2009 AC:2009, clause 7.2.1-7.2.2 4. Seat and back durability - EN 1335-3:2009 AC:2009 - Clause 7.3.1 5. Arm rests durability EN 1335-3:2009 AC:2009, clause 7.3.2 6. Arm rest downward static load test-central EN 1335-3:2009 AC:2009, clause 7.2.3 7. Stability EN 1335-3:2009 AC:2009, clause 7.1 8. Arm rest downward static load test - front EN 1335-3:2009 AC:2009, clause 7.2.4 9. Arm rest sideways static load test EN 1335-3:2009 AC:2009, clause 7.2.5 10. Swivel test EN 1335-3:2009 AC:2009, clause 7.3.3

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

centro ricerche-sviluppo laboratorio prove settore legno-arredo

Page 1 of 2

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Defects before testing: None

Overall dimensions: 750 x 750 x 1060 (h) mm (extended uncertainty = 5 mm)

Date of issue: 25-11-10

Sample name: SHINY

TEST REPORT N° 121264

Page 2 of 2

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

Side view Rear view

Bottom view

Sample weightOverall dimensions

Not determined750 x 750 x 1060 (h) mm (*)

(*) Extended uncertainties of weight and overall dimensions of the sample are 0,1 Kg and 5 mm, respectively

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

centro ricerche-sviluppo laboratorio prove settore legno-arredo

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 1Date received: 05-10-10Date of test: 07-10-10Date of issue: 25-11-10Sample name: SHINY

Office work chair: dimensions EN 1335-1:2000 AC:2002

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

1.1 SedileSeat

-adjustable with horizontal movement

1. General features

1.2 Schienale

depht:

Xadjustable with backrest inclination

inclination:

- fixed

- fixed

Backrest

X adjustable

1.3 Seat and back syncronyzed

heigth: X fixed- adjustable

inclination:

- adjustable lumbar support

X adjustable- fixed

Yes

pag. 1/2

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

TEST REPORT 121264 / 1Date of issue: 25-11-10Sample name: SHINY

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Parameter requirement measured conformity

Type of chair: C

All linear dimensions are in mm

b

SEAT

80 min 121 yes

symbol

a seat height 420 to 480 376 to 497 yesadjustment range

c

seat depth - non adjustable 380 min // //seat depth - adjustable

d

400 min 455 to 524 yesdepth of seat surface 380 min 528 yesseat width 400 min 481 yes

e inclination of seat surface - non adjustable -2° ÷ - 7° // //inclination of seat surface - adjustable

f

-2°to - 7° - 1,1° ± 0,6° * to - 13° yesBACK REST

gno requirement // //

height of the back supporting point "S" non adjust. 170 ÷ 220 200 yesheight of the back supporting point "S" adjust.

height of the back pad - adjustable in height no requirement // //height of the back pad - non adjustable in height 260 min 456 yes

h height of the upper edge of the back rest 360 min 541 yesi back rest width 360 min 491 yesk horizontal radius of the back rest 400 min > 400 yesl back rest inclination (adjustment range) no requirement 16° yes

ARM REST

o 40 min > 40 yesn length of arm rest 200 min > 200 yes

width of arm restp height of armrest - adjustable 200 to 250 // yes

height of armrest - non adjustable

r

200 ÷ 250 248 yesq distance from the front of the arm rest to the front

edge of the seat 100 min 140 yes

clear width between the arm rests 460 min 484 yesUNDERFRAME

t 195 min 264 yess maximum offset of the underframe 411 max ** 403 yes

stability dimension(**): x is the maximum horizontal distance between parts of the upper part of the chair and the axis of rotation

*The result is the average of 3 measuresUnless otherwise specified, measurement uncertainties expanded to a confidence level of about 95% are ±5 mm for linear measures, ±2° for angles,±10mm for the height of the back supporting point "S".”

The measurement uncertainties stated in this document have been determined according to UNI CEI ENV 13005:2000. They were estimatedas expanded uncertainty obtained multiplying the standard uncertainty by the coverage factor k corresponding to a confidence level of about 95%.Normally k=2.

NOTE: the back supporting point has been determined setting the back rest in its most upright position because themethod described in EN 1335-1:2000 clause 3.6 is not applicable.

Pag. 2/2

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 2Date received: 05-10-10Date of test: 08-10-10Date of issue: 25-11-10Sample name: SHINY

General design requirements EN 1335-2:2009, clause 4.1

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

a) Parts in contact by user:

Yes

Requirements Remarks

Yes

Distance of accessible movable parts shall be either≤8 mm e ≥25 mm in any position during movement.b) Corners and edges in contact by user:

Yes

Minimum radius of corners and edges:2 mmc) Edges of handles:

Yes

Minimum radius of handle edges:2 mmd) All other edges:

Yes

Rounded or chamfered:e) Ends of hollow components:

Yes

Closed or cappedf) It shall be possible to operate the adjusting devices from sitting position in the chair:g) It shall not be possible for any load bearing part to come loose unintentionally: Yes

h) Lubricated parts:All parts wich are lubricated shall be protected Yes

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 3Date received: 05-10-10Date of test: 08-10-10Date of issue: 25-11-10Sample name: SHINY

Seat and back static load test 1335-3:2009 AC:2009, clause 7.2.1-7.2.2

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat height:

Numberof cycles

highest position

horizontal

Back restinclination

mechanism

Remarks

Seat front edge static load, clause 7.2.1

Seat depth: foremost position

Seat loadN

Back restinclination

mechanism

Test results:

10 F No defects1.600

Seat and back static load test, clause 7.2.2

Back forceN

Remarks

Seat height: highest positionSeat inclination:

Numberof cycles

Back rest in height highest positionBack rest in depth

560

rearmost position

5

Position of castorsperpendicular to the base arms

Tension of mechanism spring: medium

Seat loadN

Back restinclination

mechanism

Test results:

A - B Blocked No defects

1.600

1.600 560 5 A - B Unlocked No defects

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 4Date received: 05-10-10Date of test: 08-10-10Date of issue: 25-11-10Sample name: SHINY

Seat and back durability - EN 1335-3:2009 AC:2009 - Clause 7.3.1

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat height:

highest position

Remarks

Seat and back durability clause 7.3.1

Seat inclination: horizontal

ForceN

Back rest in height highest positionBack rest in depth rearmost position

Position of castors perpendicular to the base arms

Tension of mechanism spring:

Loadingpoint

medium

Back restinclination

mechanism

Test results:

A 1.500 Unlocked No defects

Numberof cycles

120.000

40.000 CB

1200320 Blocked No defects

40.000 CB

1200320 Unlocked No defects

20.000 JE

1200320 Unlocked No defects

20.000 FH

1200320 Unlocked No defects

20.000 DG

11001100 Unlocked No defects

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 5Date received: 05-10-10Date of test: 03-11-10Date of issue: 25-11-10Sample name: SHINY

Arm rests durability EN 1335-3:2009 AC:2009, clause 7.3.2

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat height: lowest position

Arm rest durability, clause 7.3.2

Seat inclination: horizontal

Remarks

Armrest positioning: //

Loadon arm rest

NNumberof cycles

Test results:

400 60.000 No defects

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 6Date received: 05-10-10Date of test: 09-11-10Date of issue: 25-11-10Sample name: SHINY

Arm rest downward static load test-central EN 1335-3:2009 AC:2009, clause 7.2.3

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat height:

Numberof cycles

lowest position

Arm rest downward static load test - central, clause 7.2.3

Seat inclination: horizontalArmrest positioning: //

Test results:

RemarksLoad on thearm rest

750 5 See note

900 5 No defects

Note: after the functional load of 750 N the chair does not overbalance.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 7Date received: 05-10-10Date of test: 09-11-10Date of issue: 25-11-10Sample name: SHINY

Stability EN 1335-3:2009 AC:2009, clause 7.1

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Chairs with back rest inclination: no overturning with 13 discs of 10 Kg. as specified in Table 1 of EN 1335-3

: 20 N does not overturn

Minimum horizontal force for rearwards overturning of fixed back chair: 192 N

Positioning of chair components:

Horizontal forceForwards overturning

: 27 kg does not overturn Horizontal forceFront edge overturning

: //

N

does not overturn

Fixed back chairRearwards overturning

: 13

Horizontal force

Loading discs on the seat Chair with back rest inclination

: 20 does not overturn Horizontal forceSideways overturning for chairs with arms

: // Horizontal forceSideways overturning for chairs without arms

Horizontal force : //Forwards overturning for chairs with footrest

Note: The test has been carried out after the functional load on the arm rest.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 8Date received: 05-10-10Date of test: 09-11-10Date of issue: 25-11-10Sample name: SHINY

Arm rest downward static load test - front EN 1335-3:2009 AC:2009, clause 7.2.4

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat inclination:

Numberof cycles

horizontal

Arm rest downward static load test - front, clause 7.2.4

lowest positionSeat height:

Armrest positioning: //

Load on thearm rest

NRemarks

Test results:

450 5 No defects

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 9Date received: 05-10-10Date of test: 09-11-10Date of issue: 25-11-10Sample name: SHINY

Arm rest sideways static load test EN 1335-3:2009 AC:2009, clause 7.2.5

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Seat inclination:

Number ofapplications

horizontal

Arm rest sideways static load test, clause 7.2.5

lowest positionSeat height:

Armrest positioning: //

Horizontalforce

NRemarks

Test results:

400 10 No defects

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

121264 / 10Date received: 05-10-10Date of test: 09-11-10Date of issue: 25-11-10Sample name: SHINY

Swivel test EN 1335-3:2009 AC:2009, clause 7.3.3

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Position of seat:

Seat loadon point C

kg

highest position

Remarks

Swivel test, clause 7.3.3

horizontal / maximum depthSeat height:

Back rest in height highest positionBack rest in depth rearmost position

Test results:

Numberof cycles

Seat loadon point A

kg

60 35 120.000 No defects

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon