test report nr. / no. 486871 -03887 03 (edition 2) 20653:2006 -08 road vehicles - degrees of...
TRANSCRIPT
Trade Register Straubing HRB 9302 V.A.T. DE 131457658 Information pursuant to Section 2(1) DL-InfoV (Germany) at www.tuev-sued.com/imprint
Managing Director: Johann Roidt
Phone: +49 9421 55 22-0
Fax: +49 9421 55 22-99
www.tuev-sued.de/senton
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Prüfbericht / Test Report Nr. / No. 486871-03887-03 (Edition 2)
Auftraggeber Applicant
TÜV SÜD Product Service GmbH
Geräteart Type of equipment
Load Cells
Typenbezeichnung Type designation
Mod.740S No.998132(11)
Auftragsnummer / Order No.
4500207818
Prüfgrundlage Test standards
ISO 20653:2006-08 Road vehicles - Degrees of protection (IPx9k)
2011-07-05
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 2 of 16
Summary
Prüfergebnisse / Test Results Auftragsnummer / Order No.
4500207818
Die Prüfungen wurden nach folgenden Vorschriften durchgeführt: Tests were performed according to:
ISO 20653:2006-08 Road vehicles - Degrees of protection
(IPx9k)
Durchgeführte Prüfung
Test performed
Betriebsart
Operation mode
Prüfergebnis
Testresult
Betrieb Operating
Nicht in Betrieb
Non Operating
Erf
üllt
Pa
sse
d
Nic
ht
erf
üllt
Not
Pa
sse
d
IP-Schutzklasse / Degree of Protection (IP-Code)
X9k
Bemerkungen / Remarks:
Eine abschließende Funktionskontrolle obliegt dem Auftraggeber.
The final evaluation will be performed by the applicant.
Die Prüfergebnisse beziehen sich ausschließlich auf das zur Prüfung vorgestellte Prüfmuster. Ohne schriftliche Genehmigung des Prüflabors darf der Prüfbericht auszugsweise nicht vervielfältigt werden. The test results relate only to the individual item which has been tested. Without the written approval of the test laboratory this report may not be reproduced in extracts.
Datum / Date Geprüft von / Tested by Freigabe durch / Checked by Prüfergebnis / Test Result
Erfüllt / Passed
Nicht erfüllt / Not passed 2011-07-05
Reinhold Markl Responsible for testing
Johann Roidt Laboratory manager
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 3 of 16
Table of Contents
1 Administrative Data ................................................................................................................... 4
2 Details about the Test Laboratory ............................................................................................. 5
3 Description of the Equipment Under Test .................................................................................. 6
3.1 Photos of the Testsample ................................................................................................... 7
4 Operation Mode and Configuration of EUT ............................................................................. 10
5 Methods of Observation .......................................................................................................... 11
6 Referenced Regulations .......................................................................................................... 12
7 Test Results ............................................................................................................................ 13
7.1 Degrees of protection (IP-code) ....................................................................................... 14
8 Revision History ...................................................................................................................... 16
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 4 of 16
1 Administrative Data
Application details
Applicant: TÜV SÜD Product Service GmbH Dudenstraße 28 D-68167 Mannheim
Contact person: Mr. Wolfgang Jakobi
Order number: 4500207818 / 14.06.2011
Receipt of EUT: 2011-06-15
Return of EUT: 2011-06-20
Date(s) of test: 2011-06-16
Note(s): The final evaluation will be performed by the applicant.
Responsible for testing: Mr. Reinhold Markl
Responsible for test report: Mr. Reinhold Markl (kbr)
Test report checked by: Mr. Johann Roidt
Report details
Report number: 486871-03887-03
Edition: 2
Issue date: 2011-07-05
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 5 of 16
2 Details about the Test Laboratory
Details about the Test Laboratory
Company name: TÜV SÜD SENTON GmbH
Address: Äußere Frühlingstraße 45 D-94315 Straubing Germany
Laboratory accreditation: DAR-Registration No. DAT-PL-171/94-03
Contact: Mr. Johann Roidt Phone: +49 9421 5522-0 Fax: +49 9421 5522-99
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 6 of 16
3 Description of the Equipment Under Test
Equipment characteristics
Type designation: Mod.740S No.998132(11)
Parts of the system: ---
Options and accessories: ---
Type of equipment: Load Cells
Serial number: ---
Manufacturer: Tecnicas de Electronica Automatismos S.A. Barcelona (SPAIN)
Power supply: External DC supply
Version of EUT: see photo/type label
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 7 of 16
3.1 Photos of the Testsample
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 8 of 16
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 9 of 16
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 10 of 16
4 Operation Mode and Configuration of EUT
Operation Mode(s)
EUT not connected, non operation mode
List of ports and cables
No. Description Classification1 Cable type Cable length
D1 IN / OUT / SENSE dc power Unshielded Appr. 3m
EUT mounting
No. Description Type designation Serial no. or ID Weight
1 EUT mounted by cable retainers --- --- ---
List of devices connected to EUT
No. Description Type designation Serial no. or ID Manufacturer
1 --- --- --- ---
List of support devices
No. Description Type designation Serial no. or ID Weight
1 --- --- --- ---
1 Ports shall be classified as ac power, dc power or signal/control port.
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 11 of 16
5 Methods of Observation
Methods of Observation
Function Observed size Permissible range Observation method
mechanical constitution -- visual
sealing water penetration (weight)
no / no critical quantity
visual; precision scale
The final evaluation will be done by the applicant.
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 12 of 16
6 Referenced Regulations
Publikation Titel
ISO 20653:2006-08
Road vehicles - Degrees of protection (IP-Code) - Protection of electrical equipment against foreign objects, water and access
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 13 of 16
7 Test Results
Degrees of protection provided by enclosures
ISO 20653:2006-08 Road vehicles - Degrees of protection
(IPx9k)
Test performed IPx9k High Pressure Steam Cleaning
Test Result Note
Speed of turntable 5 ±1 rpm Test passed
no water penetration
no deformation;
type labels were loosened;
water penetration checked by precision
scale
Fan jet positions 0°, 30°, 60°, 90°
Distance 100 to 150 mm
Volume 14-16 l/min
Jet Pressure 80 to 100 bar
Water temperature 80 ±5°C
Test duration 30 s per position
Operation mode not operated
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 14 of 16
7.1 Degrees of protection (IP-code)
7.1.1 +Test Equipment List
Type Designation Inv.-no. Manufacturer
IPx9k System Turntable 2092 Own Construction
High Pressure Cleaner Kränzle Therm 1165-1
2093 Kränzle
IPx7 Immersion Basin 240 l / 1 m -- Own Construction
Data Aquisition Switch Unit 34970A 1967 Agilent Technologies
20 channel multiplexer 34901A 1968 Agilent Technologies
Precision scale PCB 2116 KERN
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 15 of 16
7.1.2 Testsetup
IPx9k
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany
Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected]
Test Report No. 486871-03887-03 (Edition 2) Page 16 of 16
8 Revision History
Revision History
Edition Date Issued by Modifications
1 2011-07-05 Reinhold Markl (kbr)
First Edition
2 2011-07-05 Reinhold Markl (kbr)
Seperate report for each EUT