HK-F-PC4 -008 Version 4.0 Test Report Measurement of Low Power Consumption of Electric and Electronic Appliances Report Reference No. ................. : 3015746.52ErP Tested by (name + signature) ....... : Dick Cheung ………………………………….. Reviewed by (name + signature) ... : C. S. Man ………………………………….. Date of issue.................................. : 2012-12-24 Contents ........................................ : 15 pages Testing Laboratory ...................... : DEKRA Certification Hong Kong Ltd. Testing location / address .............. : Unit 1-14, 6/F., Fuk Shing Commercial Building, 28 On Lok Mun Street, On Lok Tsuen, Fanling, N.T., Hong Kong. Applicant ...................................... : Philips Consumer Lifestyle B.V. Address ......................................... : Building TC, Tussendiepen 4, 9206 AD Drachten, The Netherlands Test specification: Standard(s) ................................... : EN 50564:2011and IEC 62301:2011 Test procedure............................... : Commission Regulation (EC) No 1275/2008 of 17 December 2008 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment; and Directive 2009/125/EC of the European Parliament and of the Council establishing a framework for the setting of ecodesign requirements for energy-related products Test object description : UV sanitizer / charger Trade Mark .................................... : PHILIPS Manufacturer ................................. : Philips Consumer Lifestyle B.V. Building TC, Tussendiepen 4, 9206 AD Drachten, The Netherlands Factory ......................................... : UV sanitizer / charger (HX6150/B; HX6150/C; HX6160/B; HX6160/C; HX6160/D): PI Electronics (China Plant) Liu Yue, Da He Village, Heng Gang Town, Long Gang County, 518173 Shenzhen, China Model/Type reference .................... : UV sanitizer / charger:HX6150/B; HX6150/C; HX6160/B; HX6160/C; HX6160/D Ratings .......................................... : UV sanitizer / charger HX6150/B; HX6150/C; HX6160/B; HX6160/C; HX6160/D: 100-240 Vac; 50/60 Hz 0,55-1,1 W (Charge mode only); 5,5-6,1 W (UV & Charge mode); Class II; Possible test case verdicts: - test case does not apply to the test object : N/A (not applicable) - test object does meet the requirement : P (Pass) - test object does not meet the requirement : F (Fail) Test program.............................................. : The test object has been submitted to a test program as mentioned on the next pages. The test results shown in this report relate only to the tests performed according to the test program. The test object has not been submitted to a full test program. © Integral publication of this document is allowed.

Upload: others

Post on 02-Jan-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

HK

-F-P

C4 -

008

Vers

ion 4

.0

Test Report

Measurement of Low Power Consumption of Electric and Electronic Appliances

Report Reference No. ................. : 3015746.52ErP

Tested by (name + signature) ....... : Dick Cheung …………………………………..

Reviewed by (name + signature) ... : C. S. Man …………………………………..

Date of issue .................................. : 2012-12-24

Contents ........................................ : 15 pages

Testing Laboratory ...................... : DEKRA Certification Hong Kong Ltd.

Testing location / address .............. : Unit 1-14, 6/F., Fuk Shing Commercial Building, 28 On Lok Mun Street, On Lok Tsuen, Fanling, N.T., Hong Kong.

Applicant ...................................... : Philips Consumer Lifestyle B.V.

Address ......................................... : Building TC, Tussendiepen 4, 9206 AD Drachten, The Netherlands

Test specification:

Standard(s) ................................... : EN 50564:2011and IEC 62301:2011

Test procedure............................... : Commission Regulation (EC) No 1275/2008 of 17 December 2008 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment; and

Directive 2009/125/EC of the European Parliament and of the Council establishing a framework for the setting of ecodesign requirements for energy-related products

Test object description : UV sanitizer / charger

Trade Mark .................................... : PHILIPS

Manufacturer ................................. : Philips Consumer Lifestyle B.V. Building TC, Tussendiepen 4, 9206 AD Drachten, The Netherlands

Factory ......................................... : UV sanitizer / charger (HX6150/B; HX6150/C; HX6160/B; HX6160/C; HX6160/D): PI Electronics (China Plant) Liu Yue, Da He Village, Heng Gang Town, Long Gang County, 518173 Shenzhen, China

Model/Type reference .................... : UV sanitizer / charger:HX6150/B; HX6150/C; HX6160/B; HX6160/C; HX6160/D

Ratings .......................................... : UV sanitizer / charger HX6150/B; HX6150/C; HX6160/B; HX6160/C; HX6160/D:

100-240 Vac; 50/60 Hz 0,55-1,1 W (Charge mode only); 5,5-6,1 W (UV & Charge mode); Class II;

Possible test case verdicts:

- test case does not apply to the test object : N/A (not applicable)

- test object does meet the requirement : P (Pass)

- test object does not meet the requirement : F (Fail)

Test program .............................................. : The test object has been submitted to a test program as mentioned on the next pages.

The test results shown in this report relate only to the tests performed according to the test program. The test object has not been submitted to a full test program.

© Integral publication of this document is allowed.

Page 2 of 15 Report No.3015746.52ErP

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Summary of testing:

Comply with Commission Regulation (EC) 1275/2008: Stage 1, 2010.01.07 Yes

Stage 2, 2013.01.07 Yes

-

Power consumption measurement (W) Availability of

standby / off mode

Power management

Standby mode* Off mode**

Model HX6150/B HX6160/B HX6150/B HX6160/B

230 V; 50 Hz 0.58 0.63 0.36 0.36 Yes Yes

115 V; 60 Hz 0.42 0.44 0.23 0.23 Yes Yes

Model HX6150/C HX6160/C

HX6160/D

HX6150/C HX6160/C

HX6160/D

-

230 V; 50 Hz 0,38 0,41 0,37 0,40 Yes Yes

115 V; 60 Hz 0,25 0,26 0,25 0,26 Yes Yes

Remark:

* Standby mode: The batteries are fully charged which is shown as a status in the load, toothbrush HX6910 (for

HX6150/B and HX6160/B) and HX9140 (for HX6150/C, HX6160/C and HX6160/D) in this case.

** Off mode: The toothbrush is not placed on charger stand

Page 3 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Copy of marking plate

UV sanitizer / charger (HX6150/B):

UV sanitizer / charger (HX6160/B):

UV sanitizer / charger (HX6150/C):

UV sanitizer / charger (HX6160/C):

UV sanitizer / charger (HX6160/D):

Revised date 2013-01-03

Page 4 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

General remarks:

Throughout this report a point is used as the decimal separator.

The test results presented in this report relate only to the object tested.

This report shall not be reproduced except in full without the written approval of the testing laboratory.

- Annex A: Appliances Types

General product information:

HX6150/B, HX6150/C, HX6160/B, HX6160/C, HX6160/D charger stand are named ‘UV sanitizer / charger’, which includes a brush storage compartment incorporating an UV-C lamp for sanitizing purpose. They incorporated with similar circuitry and with same critical components, but with slightly different of their outlooks.

The client is submitted the toothbrush, type HX6910 and HX9140 is used as a load for this ErP measurement, its rating is 4,05 Vdc (fully charged); 2 W.

Copyright © DEKRA Certification B.V., Arnhem, the Netherlands. All rights reserved.

Page 5 of 15 Report No.3015537.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

1 COMPLIANCE WITH COMISSION REGULATION (EC) No 1275/2008 -

-

One year after regulation has become into force (2010-01-07) -

Limit Measured -

OFF mode ……. ………….…………….…......: 1.00 W HX6160/B: 0.36 W

(max.)

HX6150/B: 0.36 W

(max.)

HX6150/C: 0,38 W

(max)

HX6160/C and

HX6160/D: 0,41 W

(max)

P

Standby mode- with any condition providing only a

reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function

1.00 W N/A

Standby mode- any condition providing only

information or status display, or providing only a combination of reactivation function and information or status display

2.00 W HX6160/B: 0.36 W

(max.)

HX6150/B: 0.36 W

(max.)

HX6150/C: 0,38 W

(max)

HX6160/C and

HX6160/D: 0,41 W

(max)

P

Sampling 1 unit -

4 years after regulation has become into force (2013-01-07) -

Limit Measured -

OFF mode ……. ………….…………….…......: 0,50 W HX6160/B: 0.36 W

(max.)

HX6150/B: 0.36 W

(max.)

HX6150/C: 0,38 W

(max)

HX6160/C and

HX6160/D: 0,41 W

(max)

P

Standby mode- reactivation function 1.00 W N/A

Page 6 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Standby mode – display; simple display and low power LEDs 0.1 W, larger display (e.g. for clocks) require more power.

1,00 W HX6160/B: 0.36 W

(max.)

HX6150/B: 0.36 W

(max.)

HX6150/C: 0,38 W

(max)

HX6160/C and

HX6160/D: 0,41 W

(max)

P

Sampling 1 unit

Acceptance conditions

Power ≤ 1 W

The model shall be considered to comply with the regulation if the results for off-mode and/or standby mode conditions, as applicable, do not exceed the limit values by more than 0.10 W.

P

If above criteria can not be met, three more units shall be tested. The model shall be considered to comply with this regulation if the average of the results of the latter three tests for off-mode and/or standby mode conditions, as applicable, does not exceed the limit values by more than 0.10 W.

N/A

Power > 1 W

The model shall be considered to comply with the regulation if the results for off-mode and standby mode conditions, as applicable, do not exceed the limit values by more than 10%.

N/A

If above criteria can not be met, three more units shall be tested. The model shall be considered to comply with this regulation n if the average of the results of the latter three tests for off-mode and/or standby mode conditions, as applicable, does not exceed the limit values by more than 10%.

N/A

AVAILABILITY OF “OFF MODE AND / OR “STANDBY MODE” AND POWER

MANAGEMENT

Equipment provided with, Off mode and/or Standby mode, and/or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source (except where this is inappropriate for the intended use)

P

Page 7 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

When equipment is not providing the main function, or when other energy using product(s) are not dependent on its functions, equipment shall, unless inappropriate for the intended use, offer a power management function, or a similar function, that switches equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into

- Standby mode, or

- Off mode, or

- Another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source. The power management function shall be activated before delivery.

P

If above criteria can not be met, three more units shall be tested. The model shall be considered to comply with this regulation n if the average of the results of the latter three tests for off-mode and/or standby mode conditions, as applicable, does not exceed the limit values by more than 10%.

N/A

2 TEST PROCEDURE

Applied standard ………. ……………….…..............: EN 50564:2011 and IEC

62301:2011

Name of selected mode ..…………….…...............: Off mode and standby mode

How is the mode selected or programmed............: Off mode: no load on the charger

Standby mode: the batteries are fully charged.

Sequence of events to reach the mode where the product automatically changes mode…….............:

Let the appliance unattended

Measurement method: Average reading method

If applicable, technical justification of inappropriateness for intended use

Not applicable

Page 8 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

3 TEST CONDITION AND EQUIPMENT INFORMATION

Ambient temperature(°C) ………. ………………....: 23 oC

Appliance type……. ……………….…….................: Type C

Test voltage (V) ………. ……………….….............: 115 V / 230 V

Test frequency (Hz) ………. ……………….…........: 60 Hz / 50 Hz

Total harmonic distortion of supply system (%).....: < 2%

Measured power factor. ……….….........................: 0.48

Test equipment description………. ………………..: Power meter

Test equipment model number……. ……………….: WT210

Calibration due date ………. ……………….…........: 2013-01-13

Measurement uncertainty introduced by equipment: (Measured value +0.00019 W) ± 0.00025 W; k=2

Measured values -

Measured value in W rounded to the second

decimal place (e.g. 0.52 ) -

Sample 1 Sample 2 Sample 3 Average -

OFF mode ……. …………….…......:

HX6160/B:

0.36 W

(max.)

HX6150/B:

0.36 W

(max.)

HX6150/C:

0,38 W

(max)

HX6160/C

and

HX6160/D:

0,41 W

(max)

-- -- --

-

Sample 1 Sample 2 Sample 3 Average -

Standby mode- with any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function

-- -- -- --

-

Sample 1 Sample 2 Sample 3 Average -

Page 9 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Standby mode- any condition providing only information or status display, or providing only a combination of reactivation function and information or status display

HX6160/B:

0.36 W

(max.)

HX6150/B:

0.36 W

(max.)

HX6150/C:

0,38 W

(max)

HX6160/C

and

HX6160/D:

0,41 W

(max)

-- -- --

-

Power value measured under stable condition?

Yes -

Page 10 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

Clause Requirement – Test Result Verdict

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

4 INSTRUMENTATION CIRCUIT FOR TESTING

Connection arrangement for products powered directly from an a.c. power

supply for lower power loads

OR

Connection arrangement for a product powered via an external power

supply for lower power loads

Page 11 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Photos of appliance:

Charger: HX6150/B

Charger: HX6160/B

Page 12 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Charger: HX6150/C

Charger: HX6160/C

Page 13 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Charger: HX6160/D

Page 14 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Annex A: Appliances Types

Type Description Circuit diagram

Type A

The product has no secondary function and no power switch. The appliance operates whenever plugged in. There may be some internal regulation of the load (eg thermostat or temperature control device). There is no standby mode. There is no power mode

Examples of Type A products: electric kettles (with no cut-out), some small kitchen products, electric storage water heaters, refrigerators.

Type B

The product has a power switch. The primary function of the product operates when it is manually turned on by the power switch and stops when turned off. Power switches can be the auto-off type (automatically turns off at the completion of the operation). As there is no secondary function, the low power mode usually takes little or no power.

Examples of Type B products: electric heaters (with no thermostat), hair dryers, toasters, electric kettles (with boil cut-out), some major appliances (some dishwashers, clothes washers and clothes dryers), many small kitchen appliances, cooktops, some ovens.

Type C

The product has no mains power switch but has a secondary function that controls the primary function or performs some related function. There may be a remote control or low voltage power switch. Low power mode energy may be associated with the secondary function.

Examples of Type C products: bread makers, some small kitchen appliances, some major appliances (some dishwashers, clothes washers and clothes dryers), some microwave ovens, any product with a remote control and no hard off switch, any product with a “soft” (electronic) power switch.

Type D

The product has a power switch that disconnects the primary function and has a secondary function that is permanently connected to the power. Low power mode energy may be associated with the secondary function.

Examples of Type D products: conventional ovens, some types of heaters, microwave oven, any product that requires some power for a secondary function (clock, display, timer etc.).

Type E

The product has a power switch that disconnects the primary function. It may have a secondary function that is permanently connected to the power and/or one that is disconnected with the power switch. Low power mode energy may be associated with the permanently connected secondary function. Other low power modes may be associated with the switched secondary function.

Examples of Type E products: some microwave ovens, some major appliances (some dishwashers, clothes washers and clothes dryers), some types of heaters, any product that requires some power for a secondary function (clock, display, timer etc.), any product with permanently connected electronics or EMC filters, low voltage switches and controls or wired remote controls.

Type F

The product has an external power supply that provides the product with power. Supply is usually extra low voltage (<50 V), may be a.c. or d.c. and may be connected via a plug. Internal product configurations may be A to E above. All functions require the external power supply to be connected to mains power. Energy consumption is associated with the power supply and there may be numerous low power modes.

Examples of Type F products: some small personal care products, some small kitchen appliances, any product that is normally connected to mains power via an external power supply.

Page 15 of 15 Report No.3015746.52ErP

Power consumption in off and standby mode

DEKRA Certification Hong Kong Ltd.

Unit 1-14, 6/F, Fuk Shing Commercial Bldg., 28 On Lok Mun Street, Fanling, Hong Kong Tel: +852 2669 5740, Fax:+852 2675 3262, www.dekra-certification.com

H

K-F

-PC

4 -

008

Vers

ion 4

.0

Type G

The product has an external power supply that provides the product with power, mainly for battery charging. The product’s primary function is normally performed with key part of the product disconnected from the power supply (battery operated and portable products), but some products may be used with the power supply connected. Supply is usually extra low voltage (<50 V) and may be a.c. or d.c. and is usually connected via a detachable plug. For these types of products the battery may be either charged while remaining inside or connected to the product (in this case the power supply may be attached to the product itself via a plug, or the product may sit in a dedicated cradle which charges the product when placed in the cradle while not in use) or the battery may be disconnected from the product for charging purposes (may require a dedicated or generic battery charging device). Energy consumption is usually associated with the power supply (even when the product is disconnected) and there can be low power modes and/or active modes associated with battery charging and product use (see Clause A.2). Examples of Type G products: portable battery operated products such as battery shavers,

electric toothbrushes, portable vacuum cleaners