Form No. 7/A – TSR (Rev.03)

BAGAVATHI ANA LABS

TEST REPORT Name & Address of the Customer : Test Report No.: BALPL/14-15/ITD- 0731/1

M/s. SRINIVASA & NARASIMHA SCENITIFIC

REASEARCH ,& DEVELPOMENT TRUST

Issue Date :11-8-2014

H.No-2-1-16-1, Beside Dhana Lakshmi Agro Industries,

O.V Road, Revenue colony Kandakur, Prakasam Dist. Your Ref : Nil

Sample Particulars: Crystalline Copper Metal – C – 2101 Date : Nil

Qty : 1 No. Date of Registration : 02.08.2014

Method of Testing : IS: 440-1964

Date of commencement of testing : 04.02.2014

Test Required : As given below Date of completion of testing : 09.08.2014

Sample condition at receipt : Found ok

Sample tested as received

Sampling Method: Sample collected and submitted by the customer Page: 1 of 1

Test Results

Sl. No Test Parameter Results obtained

1. Copper as Cu, % by mass 99.90

2. Iron as Fe, ppm 74

3. Zinc as Zn, ppm 802

Interpretation of results: Nil Deviation from test method and condition: Nil

Bhagavathi Ana Labs Pvt. Ltd. Central Laboratory - Industrial Testing Division (A Bureau Veritas Group Company) Plot No. 7-2-C 14, Industrial Estate, Sanathnagar, Hyderabad - 500 018.

INDIA Tel.: +91 40 23811535, 23711536 • www.bhagavathianalabs.com

Note: This Report is subject to the terms and conditions mentioned overleaf

A260499

Page 8: Testing Reports

Form No. 7/A – TSR (Rev.03)

BAGAVATHI ANA LABS

TEST REPORT

Name & Address of the Customer : Test Report No.: BALPL/14-15/ITD- 0731/2

M/s. SRINIVASA & NARASIMHA SCENITIFIC

REASEARCH ,& DEVELPOMENT TRUST

Issue Date :11-8-2014

H.No-2-1-16-1, Beside Dhana Lakshmi Agro Industries,

O.V Road, Revenue colony Kandakur, Prakasam Dist. Your Ref : Nil

Sample Particulars: Crystalline Copper Metal – C – 2101 Date : Nil

Qty : 1 No. Date of Registration : 02.08.2014

Test Required : As given below

Date of commencement of testing : 04.08.2014

Date of completion of testing : 09.08.2014

Sample condition at receipt : Found ok

Sample tested as received

Sampling Method: Sample collected and submitted by the customer Page: 1 of 1

Test Results

Sl. No Test Parameter Results obtained

1. Tensile Strength, MPa 81

2. Percentage Elongation 8.0

3. Hardness, HBW 28

4. Yield Strength, MPa 68

Interpretation of results: Nil Deviation from test method and condition: Nil

Bhagavathi Ana Labs Pvt. Ltd. Central Laboratory - Industrial Testing Division (A Bureau Veritas Group Company) Plot No. 7-2-C 14, Industrial Estate, Sanathnagar, Hyderabad - 500 018.

INDIA Tel.: +91 40 23811535, 23711536 • www.bhagavathianalabs.com

Note: This Report is subject to the terms and conditions mentioned overleaf

A260500

Page 9: Testing Reports
Page 10: Testing Reports

/////////////////////////////////////////////////////////////////////////

////////

/// Peak Data Ascii Dump (XRD)

///

/////////////////////////////////////////////////////////////////////////

////////

Group : KP

Data : KP

File Name : C2101.PKR

# Peak Datafile

comment = C2101

date & time = 21-08-15 10:30:18

# Measurement Condition

X-ray tube

target = Cu

voltage = 40.0 (kV)

current = 30.0 (mA)

Slits

divergence slit = 1.00000 (deg)

scatter slit = 1.00000 (deg)

receiving slit = 0.30000 (mm)

Scanning

drive axis = Theta-2Theta

scan range = 10.000 - 80.000

scan mode = Continuous Scan

scan speed = 4.0000 (deg/min)

sampling pitch = 0.0200 (deg)

preset time = 0.24 (sec)

# Peak Data List [ Total No. = 12 ]

No. <2Theta> < d > < I > <I/Io> < FWHM > <integrated I>

1 15.3000 5.78645 72 26 1.8800 5021

2 16.1800 5.47366 74 27 2.4800 5520

3 17.8000 4.97898 25 9 1.0400 1475

4 19.7600 4.48931 23 8 1.4400 1719

5 21.0600 4.21504 60 22 1.6000 5262

6 22.8683 3.88566 272 100 1.5167 17819

7 24.1200 3.68678 64 24 0.8000 3020

8 25.1400 3.53946 16 6 0.8200 984

9 34.1000 2.62716 16 6 0.8000 608

10 34.7200 2.58165 32 12 1.0000 1451

11 35.9000 2.49946 8 3 0.0000 0

12 77.4900 1.23080 9 3 0.3800 212

Page 11: Testing Reports
Page 12: Testing Reports

MELTING POINT OF C2101 -8M

Apparatus’ used: MP

Instrument model : MP 120

Range of temp scanning: up to 1500oc

Heating rate: 1-20 oc

Melting point Range Found: 1120-1135 oc

Page 13: Testing Reports
Page 14: Testing Reports
Page 15: Testing Reports
Page 16: Testing Reports
Page 17: Testing Reports
Page 18: Testing Reports

MLS/QCF/03 MASCOT LABORATORY SERVICES 0356No.93, 3rd Phase, 7th Main, Peenya Industrial Area, Bangalore - 560 058.•

if (O); 080-28393476, Telefax: 080-41273119, Website :www.mascotlaboratory.comE-mail: [email protected]

A Unit of MIs. Essen & Co.Accredited by NABL

Approved by Ministry of Defence (DGQA) BEML, Bangalore for Chemical/Mechanical, Metallography and NDT.•MASCOTWHeRe PROGRESSIS CON1]NUOUS

T. C. No. MLS/2015-2016/4290

1. CustomerName & Address

2. Customer Reference

3. Date of Receipt

4. Date of Testing

5. Date of Completion of Test

6. Test Conducted

7. Test Method

8. Description of the sample

LAB No.

TEST REPORT

Date: 15.06.2015

Mis. RASAKALPA ANCIENT INDIANTECHNOLOGY DEVELOPMENT CENTREH.No.2-1-16/1, Beside Dhana Lakshmi Agro Industries,O.V. Road, Revenue Colony, Kandukur-523105, PrakasamDist., Andhra Pradesh.

No: MLS/QTNI2015-16/015, Dated: 15.05.201511.06.2015

13.06.2015

13.06.2015

Electrical Conductivity Test

IS: 5082-1998, RA - 2003

Material Code: C-2101, Ancient Name: Kopu Tamra Loham,Modem Name: Copper Metamaterial, Shape: RechangularBlack(Metal), Weight in grams: 400

TEST RESULTS

MLS-2930

• Electrical Conductivity at 20°C = 72.5% lACS

--------------------~~-------------------

Page 1 of 1l

Checked by:Tested by:J Authorised Signatory

Vinay~ ~ Ku~karnlClllel M*Oager -Operat;ons/QUafitrNote:

1. Sampling not done by us. Results related only to the samples submitted.2. This certifitate shall not be. reproduced in par' or full and cannot be used as evidence in a court of law without prior permission in writing.3. Total liability of tbe Labontory is Limited to the Invoiced Amount.4. Sample will be preserved for a maximum of 30 days from the date of test certiflcate, After which no complaint will be entertained regarding test results.

Page 19: Testing Reports

 

                                                   Mascot lab testing report ‐4th melting ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

 

Page 20: Testing Reports

 

Page 21: Testing Reports

 

Page 22: Testing Reports

 

Page 23: Testing Reports

 

Page 24: Testing Reports

 

Page 25: Testing Reports

 

Page 26: Testing Reports

 

 

Page 27: Testing Reports

 

 

Page 28: Testing Reports

 

Page 29: Testing Reports

 

Page 30: Testing Reports

 

Page 31: Testing Reports

 

Page 32: Testing Reports

 

Page 33: Testing Reports

 

Page 34: Testing Reports