CONTINUOUS BEAD OF FIRESTONE
METAL COUNTERFLASHING BY OTHERS
ULTRAPLY TPO MEMBRANE
ULTRAPLY TPO BONDING ADHESIVE
NOTES:1.
REGULAR MAINTENANCE OF COUNTERFLASHING2.AND SEALANTS REQUIRED. NOT INCLUDED ASPART OF THE FIRESTONE WARRANTY.
CONTINUOUS BEAD OF AP SEALANT
CONTINUOUS BEAD OF FIRESTONE WATERBLOCK
WATERBLOCK
APPROPRIATE FIRESTONE FASTENER
FIRESTONE TERMINATION BAR
REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.
12" (304.8 mm) O.C. MAX.
USE APPROPRIATE BASE TIE-IN
3" (76.2 mm) MIN. FACE (SEE NOTES)
METAL COUNTERFLASHING SHALL BE 24 GAUGE3.PRE-FINISHED STEEL OR .032" MIN. ALUMINUMFORMED WITH HEMMED LOWER EDGE.
12" (304.8 mm) O.C. MAX.
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPO
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
TM
MAXIMUM WARRANTY:
TERMINATION WITH SURFACE MOUNTEDCOUNTERFLASHING AND TERMINATION BAR
ALL
1/1/2006UT-T-6
20 YEARS
CONTINUOUS BEAD OF AP SEALANTOR HIGH GRADE SEALANT
WALL / CURB(MASONRY /CONCRETESUBSTRATE
ONLY)
MASONRY AND CONCRETEWALLS / CURBS MUST BE
WATERPROOFED ANDMAINTAINED IN ORDER
FOR ANY SURFACEMOUNTED TERMINATION
TO BE EFFECTIVE.
OR ULTRAPLY TPO GP SEALANT
APPROPRIATE FASTENER
4. INSTALL FIRESTONE TERMINATION BARWITH 1/4" (6.4 mm) GAP BETWEEN ADJOININGSECTIONS.
5. TERMINATION BAR MUST BE CUT AT INSIDE AND OUTSIDE CORNERS. DO NOT BEND
AROUND CORNERS.
6.
7. INSTALL METAL WORK IN ACCORDANCE WITHCURRENT SMACNA RECOMMENDATIONS.
TERMINATION BAR MUST BE FASTENED WITHIN1" (25.4 mm) MAX. OF ALL SECTION ENDS.
FIRESTONE INSULATION
SUBSTRATE
NOTES:1.
INSTALL METAL WORK TO MANUFACTURER'SREQUIREMENTS OR SMACNA RECOMMENDATIONS.
GP SEALANT IS REQUIRED ALONG ENTIRE UPSLOPE3.EDGE OF QUICKSEAM FLASHING WHEN ROOFSLOPE IS 1" (25.4 mm) PER FOOT OR GREATER.
ULTRAPLY TPO
ULTRAPLY TPO QUICKPRIME
DRIP/GRAVEL STOP EDGEMETAL (SEE NOTES)
CONTINUOUS CLEAT
4.
WALL
5.5" TPO QUICKSEAM FLASHING IF SHOP FABRICATED METAL EDGE IS USED ITMUST MEET ANSI/SPRI ES-1 OR AN FM STANDARD.
MEMBRANE
FLANGE OF METAL MUST BE FULLY SUPPORTED5.BY WOOD AND TERMINATED AT LEAST 1/2"(12.7 mm) FROM EDGE OF WOOD.
WOOD NAILER MUST BE INSTALLED TO MEETAPPLICABLE BUILDING CODES OR 200 LBS PERLINEAR FOOT MINIMUM IN ANY GIVEN DIRECTION.
ON BALLASTED ROOFS, GRAVEL STOP HEIGHT6.MUST MEET OR EXCEED BALLAST OR PAVERHEIGHT (2" (50.8 mm) MIN. ABOVE ROOF SURFACE).
1/2" (12.7mm) MIN.
1/2" (12.7mm) MIN.
1/4" (6.35 mm) TO1/2" (12.7 mm)
REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.
2.1-1/4" HOT DIPPED GALVANIZED ROOFNAILS AT 4" (101.6 mm) O.C. MAX.
WOOD NAILER (SEE NOTES)
1-1/4" HOT DIPPEDGALVANIZED ROOF NAILSAT 6" (152.4 mm) O.C. MAX.
ISSUE / REVISIONDATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
Ul t r aPl y TPOTM
BUI LDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.comTM
MAXIMUM WARRANTY:
ROOF EDGE WITH FASCIA METAL BY OTHERS
ALL5/1/2010 UT-RE-20
20 YEARS
CONTINUOUS BEAD OFULTRAPLY TPO GPSEALANT (SEE NOTES)
CONTINUOUS BEAD OFULTRAPLY TPO GP
SEALANT (REQUIRED)
ULTRAPLY TPO BONDINGADHESIVE (ADHEREDSYSTEM ONLY)STOP (SEE NOTES)
OPTIONAL GRAVEL
IF THE FLANGE OF THE METAL EDGE IS NOT7.COMPLETELY COVERED WITH QUICKSEAMFLASHING, THEN AN ADDITIONAL PIECE OFQUICKSEAM FLASHING SHALL BE INSTALLEDAT ALL METAL SPLICES. REFER TO UT-RE-27.
THIS DETAIL IS APPROVED FOR A MAXIMUMOF 20 YEARS. REFER TO DETAIL UT-RE-21
FOR 25 YEAR REQUIREMENTS.
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
MAXIMUM WARRANTY:
PENETRATION WITH TPO PENETRATION POCKET KIT
ALL
1/1/2006UT-P-8
20 YEARS
FIRESTONE INSULATION
SUBSTRATE
FIRESTONE INSULATION
NOTES:1.
DO NOT USE OVER EXISTING PENETRATION POCKETS.4.
IF FIELD MEMBRANE IS CUT FOR INSTALLATION, THEMEMBRANE MUST BE REPAIRED WITH TPO MEMBRANEPRIOR TO INSTALLATION OF THE PENETRATION POCKET.MEMBRANE MUST BE INSTALLED WITHIN 1/2" (12.7 mm)
6.
OF PENETRATION.
PENE
TRAT
ION
PENE
TRAT
ION
7.
FIRESTONE POURABLE SEALER MOUNDED TO SHEDWATER (MINIMUM DEPTH OF 2" (50.8 mm), REMAINDER OFPOCKET MAY BE FILLED WITH A NON - SHRINKING GROUT.
3.
ULTRAPLY TPO QUICKPRIME REQUIRED ON PENETRATIONSAND MEMBRANE INSIDE OF PENETRATION POCKET.
PRE-MOLDED ULTRAPLY TPO PENETRATION POCKET
8.
6" (152.4mm)
REFER TO FIRESTONE WEBSITE FOR MOST CURRENTINFORMATION.
1" (25.4 mm) MIN.
NON-
SHRI
NKIN
G GR
OUT
ULTRAPLY TPO BONDING ADHESIVE
REMOVE ALL EXISTING FLASHINGS, LEADS, ETC. PIPE2.SURFACE MUST BE FREE OF ALL RUST, GREASE, INSULATION, ETC.
DO NOT USE WHEN SERVICE LINE TEMP. EXCEEDS 180°F.5.REFER TO UT-P-6 & 7.
(ADHERED SYSTEM ONLY)
WELDED SPLICE 2" (50.8 mm) MIN.
SUBSTRATE
PRECUT PVC PIPE
FIRESTONE POURABLE SEALER
ULTRAPLY TPO QUICKPRIME (SEE NOTES)
ULTRAPLY TPO MEMBRANE
9. REFER TO UT-P-15 OR 16 FOR MAS.
SUBSTRATE
FIRESTONE INSULATION
SUBSTRATE
PENE
TRAT
ION
(HOT
STA
CK)
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPO
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
TM
MAXIMUM WARRANTY:
PENETRATION (HOT STACK) WITH ULTRAPLY TPOFLASHING (UNSUPPORTED)
ALL
1/1/2006UT-P-6
20 YEARS
1/2" -
1" (1
2.7 m
m - 2
5.4 m
m)
WELDED SPLICE2" (50.8 mm) MIN.
8" (2
03.2
mm) M
IN.
ULTRAPLY TPO FLASHING(UNSUPPORTED)
ULTRAPLY TPO BONDING ADHESIVE
STAINLESS STEELCLAMPING RING
CONTINUOUS BEADOF ULTRAPLY TPOGP SEALANT
INSULATED METALSLEEVE BY OTHERS
ULTRAPLY TPO BONDING ADHESIVE(SEE NOTES)
ULTRAPLY TPO MEMBRANE
NOTES:1.
REMOVE ALL EXISTING FLASHINGS, LEADS,2.ETC. PIPE SURFACE MUST BE FREE OF ALLRUST, GREASE, INSULATION, ETC.PIPE MUST BE ANCHORED TO ENSURE3.
NO WRINKLES OR FOLDS UNDER CLAMPING4.
REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.
STABILITY.
RING.
FIELD FABRICATED METALHOOD BY OTHERS (REQUIRED)
FIRESTONE INSULATION
MEMBRANE AND INSULATION FOR FULLYADHERED SYSTEMS.
BONDING ADHESIVE REQUIRED BETWEEN5.
FIRESTONE FASTENER AND HD ORHD PLUS SEAM PLATE AT 12"
6.
(304.8 mm) O.C. MAX. (SEE NOTES)
FIRESTONE FASTENER AND HD SEAM PLATEREQUIRED FOR MAS ONLY. IF FASTENERCANNOT BE INSTALLED AS ILLUSTRATED,REFER TO DETAILS UT-P-15 & 16.
CONTINUOUS BEAD OFAP SEALANT OR HIGH
GRADE SEALANT
7.
(UNSUPPORTED) OR ULTRAPLYTPO MEMBRANE AS FLASHING
ULTRAPLY TPO FLASHING
WHEN REINFORCEMENT OF TPO MEMBRANEIS EXPOSED, REFER TO UT-LS-14 FOR CUTEDGE SEALANT APPLICATION.
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
MAXIMUM WARRANTY:
LAP SPLICE WITH 2" HAND WELD
ALL
1/1/2006UT-LS-2
20 YEARS
SLOPE
2" (50.8mm) MIN.
NOTES:1. REFER TO FIRESTONE WEB SITE FOR MOST
CURRENT INFORMATION.
WHEN POLYESTER REINFORCEMENT OF TPOIS EXPOSED, APPLY CUT EDGE TREATMENT TOENTIRE EXPOSED EDGE. REFER TO UT-LS-14.
2" (50.8mm) MIN.
6" (152.4 mm)
FIRESTONE FASTENER ANDHD OR HD PLUS SEAM PLATE
SLOPE 2" (50.8mm) MIN.
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
MAXIMUM WARRANTY:
LAP SPLICE WITH 1-1/2" AUTOMATIC WELDER
ALL
1/1/2006UT-LS-1
20 YEARS
SLOPE
1-1/2" (38.1mm) MIN.
NOTES:1. REFER TO FIRESTONE WEB SITE FOR MOST
CURRENT INFORMATION.
WHEN POLYESTER REINFORCEMENT OF TPOIS EXPOSED, APPLY CUT EDGE TREATMENT TOENTIRE EXPOSED EDGE. REFER TO UT-LS-14.
2" (50.8mm) MIN.
6" (152.4 mm)
FIRESTONE FASTENER ANDHD OR HD PLUS SEAM PLATE
SLOPE 1-1/2" (38.1mm) MIN.
NOTES:1.
2.
USE APPROPRIATE
BASE TIE-IN DETAIL
REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.WELDED SPLICE (SEE NOTES)
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTS
NOBODY COVERS YOU BETTER.www.firestonebpco.com
TM
MAXIMUM WARRANTY:
INSIDE CORNER
ALL
1/1/2006UT-C-5
20 YEARS
REFER TO DETAIL UT-LS-1 OR 2 FOR WELDWIDTH.
USE APPROPRIATE TERMINATION DETAIL
ULTRAPLY TPO MEMBRANE
PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDECORNER WELDED IN PLACE (SEE NOTES)
3. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USED IN LIEU OF PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDE CORNER FOR A MAXIMUM WARRANTY OF 15 YEARS .
4. WHEN REINFORCEMENT OF TPO MEMBRANEIS EXPOSED, REFER TO UT-LS-14 FOR CUTEDGE SEALANT APPLICATION.
USE APPROP.BASE TIE-IN
NOTES:1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION.
REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.
ULTRAPLY TPO 18" CURBFLASHING OR MEMBRANE HEAT
WELDED TO ULTRAPLY TPO
ULTRAPLY TPO MEMBRANE
ULTRAPLY TPO T-JOINT COVERWELDED IN PLACE (SEE NOTES)
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
MAXIMUM WARRANTY:
INSIDE CORNER WITH CONTINUOUS WALL FLASHING
ALL
1/1/2006UT-C-4
20 YEARS
PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDECORNER WELDED IN PLACE (SEE NOTES)
3. T-JOINT COVER REQUIRED FOR .060 GAUGE MEMBRANE ONLY.4. ULTRAPLY TPO FLASHING (UNSUPPORTED) (4"x4" MIN. WITH
ROUNDED CORNERS) MAY BE USED IN LIEU OF T-JOINT COVER.
DETAIL
(FIELD SHEET)
USE APPROPRIATE TERMINATION DETAIL
5. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USED IN LIEU OF PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDE CORNER FOR A
MAXIMUM WARRANTY OF 15 YEARS .6. WHEN REINFORCEMENT OF TPO MEMBRANE IS EXPOSED, REFER
TO UT-LS-14 FOR CUT EDGE SEALANT APPLICATION.FIELD SHEET (SEE NOTES)
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTS
NOBODY COVERS YOU BETTER.www.firestonebpco.com
TM
MAXIMUM WARRANTY:
OUTSIDE CORNER
ALL
1/1/2006UT-C-1
20 YEARS
USE APPROPRIATE
TERMINATION DETAIL
USE APPROPRIATE
BASE TIE-IN DETAIL
PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDECORNER WELDED IN PLACE (SEE NOTES)
NOTES:1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT
INFORMATION.REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.
ULTRAPLY TPO 18" CURB FLASHINGOR MEMBRANE HEAT WELDED TOULTRAPLY TPO FIELD SHEET (SEE NOTES)
ULTRAPLY TPO MEMBRANE (FIELD SHEET)
3. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USED IN LIEU OF PRE-MOLDED ULTRAPLY TPO INSIDE/OUTSIDE CORNER FOR A MAXIMUM WARRANTY OF 15 YEARS .
4. WHEN REINFORCEMENT OF TPO MEMBRANE ISEXPOSED, REFER TO UT-LS-14 FOR CUT EDGESEALANT APPLICATION.
FIRESTONE INSULATION
SUBSTRATE
WALL / CURB
NOTES:1.
3.
WELDED SPLICE (SEE NOTES)
ULTRAPLY TPO MEMBRANE
ULTRAPLY TPO BONDING ADHESIVE (SEE NOTES)
USE APPROPRIATETERMINATION
REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.
POSI
TION
PLA
TE 1/
2" (1
2.7 m
m)
MIN.
ABO
VE F
INIS
HED
ROOF
ULTRAPLY TPO MEMBRANE MUST EXTEND1/2" (12.7 mm) BEYOND HD OR HD PLUS SEAM PLATE (SEE NOTES)
ULTRAPLY TPO BONDING ADHESIVE
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPO
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
TM
MAXIMUM WARRANTY:
BASE TIE-IN WITH HD SEAM PLATES FASTENEDTO WALL / CURB
ALL
1/1/2006UT-BT-2
20 YEARS
4.
REFER TO UT-BT-16 & 17 FOR MEMBRANESECUREMENT AT CORNERS.
FIRESTONE FASTENER AND HD OR HD PLUS SEAMPLATE AT 12" (304.8 mm) O.C. MAX. (SEE NOTES)
ULTRAPLY TPO 18" CURB FLASHING OR MEMBRANE
BONDING ADHESIVE REQUIRED BETWEEN MEMBRANEAND INSULATION FOR FULLY ADHERED SYSTEMS.
5. WHEN REINFORCEMENT OF TPO MEMBRANE ISEXPOSED, REFER TO UT-LS-14 FOR CUT EDGESEALANT APPLICATION.
FIRESTONE INSULATION
SUBSTRATE
WALL / CURB
NOTES:1.
MAXIMUM 6" (152.4 mm) LONG FASTENERS.3.(NOTE: WOOD BLOCKING MAY BE SUBSTITUTEDFOR INSULATION TO REDUCE FASTENER LENGTH REQUIREMENT).
4.
6.
WELDED SPLICE (SEE NOTES)
ULTRAPLY TPO MEMBRANE
ULTRAPLY TPO BONDING ADHESIVE (SEE NOTES)
USE APPROPRIATETERMINATION
BONDING ADHESIVE REQUIRED BETWEEN MEMBRANEAND INSULATION FOR FULLY ADHERED SYSTEMS.
REFER TO FIRESTONE WEBSITE FOR MOSTCURRENT INFORMATION.
ULTRAPLY TPO BONDING ADHESIVE
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTSNOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
MAXIMUM WARRANTY:
BASE TIE-IN WITH HD SEAM PLATES FASTENED TO DECK
ALL
1/1/2006UT-BT-1
20 YEARS
REFER TO DETAIL UT-LS-1 OR 2 FOR WELD WIDTH.2.
FIRESTONE FASTENER AND HD OR HD PLUS SEAMPLATE AT 12" (304.8 mm) O.C. MAX. (SEE NOTES)
ULTRAPLY TPO 18" CURB FLASHING OR MEMBRANEIN CASE OF OBSTRUCTION REFER TO DETAIL UT-BT-5.
5. REFER TO UT-BT-16 & 17 FOR MEMBRANESECUREMENT AT CORNERS.HD OR HD PLUS SEAM PLATE POSITIONED
1/2" (12.7 mm) BEYOND WALL/CURB
7. WHEN REINFORCEMENT OF TPO MEMBRANE ISEXPOSED, REFER TO UT-LS-14 FOR CUT EDGESEALANT APPLICATION.
NOTES:1.
HOLE IN MEMBRANE SHOULD EXTEND A MINIMUM OF 1/2"2.
INSULATION ADJACENT TO DRAIN TO BE APPROPRIATE3.FIRESTONE INSULATION WITH APPROPRIATE BONDING
FIRESTONE WATERBLOCK MIN. OF 1/2 OF 10 OZ (295 ml)4.
IN REROOF APPLICATIONS:5.- REMOVE EXISTING FLASHINGS DOWN TO METAL BOWL- REPAIR OR REPLACE BROKEN DRAIN COMPONENTS- DRILL AND TAP BROKEN DRAIN BOLTS AND REPLACE
(12.7 mm) BEYOND CLAMPING RING AND SHOULD NOT BE
IF NECESSARY.
SUBSTRATE
FIRESTONE INSULATION
ULTRAPLY TPO BONDING
ULTRAPLY TPO
CONTINUOUS BEAD OFFIRESTONE WATERBLOCK
COMPRESSION RINGSTRAINER BASKET
FIRESTONE INSULATION
SUBSTRATE
SURFACE.
TUBE PER 4" DRAIN. USE ADDITIONAL WATERBLOCK
SMALLER THAN THE DIAMETER OF THE LEADER PIPE.
FOR LARGER DRAINS.
1/2" (12.7mm) MIN.SEE NOTES
REFER TO FIRESTONE WEB SITE FOR MOST CURRENTINFORMATION.
(SEE NOTES)
MEMBRANE
12" (304.8 mm)
ADHESIVE (ADHERED
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
UltraPly TPOTM
BUILDING PRODUCTS
NOBODY COVERS YOU BETTER.www.firestonebpco.com
TM
MAXIMUM WARRANTY:
ROOF DRAIN
ALL
1/1/2006UT-D-1
20 YEARS
SYSTEMS ONLY)
IF FIELD SEAM EDGE IS WITHIN 9" (228.6 mm) OF DRAIN COMPRESSION RING, TPOTARGET PATCH REQUIRED.IF FIELD SEAM EDGE IS WITHIN 9" (228.6 mm) TO 18" (457.2 mm) OF DRAIN COMPRESSIONRING, HEAT WELD A LAYER OF ULTRAPLY TPO FLASHING (UNSUPPORTED) OR ULTRAPLY
SUMP AREA FIELD SEAM REQUIREMENTS:
A.
B.
TPO MEMBRANE CENTERED OVER SEAM EDGE. FLASHING MUST EXTEND 3" (76.2 mm) MIN.BEYOND EDGE OF SUMP.
1" MAX.(25.4 mm)
A3.1
TPO Roof Details