Page 1: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

THERMOPROGRAM

DIGITAL PROGRAMMABLE

THERMOSTAT

TH 350

INSTRUCTIONS FOR USETH350E 24806610 13-03-13

Page 2: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

2

Congratulations on the purchase of this TH350 thermostat.For best performance and to enable the best use of this programmable thermostat's characteristics and functions please read this manual carefully and keep it available for future reference.

WARNINGS FOR THE INSTALLER

• Read the warnings contained herein with care as they furnish important instructions regarding safe use, instal-lation and maintenance.

• After removing the packaging check the condition of the unit.

• The system must be installed in compliance with current safety standards.

• The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.

• Should the unit be in need of repair contact only a tech-nical support centre authorised by the manufacturer.

• Failure to comply with the above instructions may com-promise the unit's safety.

THERMOPROGRAM TH350

The TH350 programmable thermostat has been designed to ensure perfect temperatures any time of day, any day of the week.The TH350 features a new temperature control system and new functions.The TH350 has been designed to guarantee ideal tem-perature conditions and to adapt itself to all types of sys-tems having differing thermal inertias (convector heaters, radiant underfloor heating, electric heaters, etc.).It is possible to choose between differential control mode and integral proportional control mode (management of cycles/hour). The latter allows the programmable ther-mostat to reduce the time the boiler is in operation as the room temperature approaches the desired temperature. This provides a greater reduction in consumption while at the same time providing the highest levels of comfort.The TH350 has new features and functions that include: • a backlit display;• the possibility to set boiler ignition down to the quar-ter-hour;• a new AUTOMATIC ADVANCE function that allows the TH350 to self-learn the periodicity required to achieve the desired temperature at any chosen point in time;• an option to calibrate the measured room temperature;

Use only ALKALINE batteries

Page 3: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

• the use of a GSM relay interface which makes it possible to remotely activate a manual or timer controlled pro-gramme thus ensuring a welcoming return home.Wall mounting the installation takes only minutes. The thermostat can be connected to the heating/cooling installation simply by means of two wires.Three alkaline LR03 1.5V penlight AAA batteries are used to power TH350 for over a year. Once installed the unit is ready for operation based on its permanent memory standard programme. Based on actual needs, the programme can be modified as required by setting the desired temperatures for different times of the day and week. The TH350 can be programmed with great ease, even before it is installed. The spacious backlit display makes this easier, because at any time it permits the viewing of all data and programmes which can subsequently be changed as required.Pressing the programming buttons causes the display to light up for about 15 seconds from the last time any key was pressed. The thermal differential is programmable from 0°C to 0.9°C. The TH350 can control both heating and air-condi-tioning systems, and can be installed as a replacement for a previous on/off programmable thermostat.

Thermal differential is programmable from 0°C to 0.9°C.Suitable for systems with differing thermal inertias (convector heaters, underfloor heating, electric heaters) ensuring best system use with the lowest possible consumption.

Proportional/integral adjustment programmeAllows for energy consumption optimisation with maximum room comfort thus reducing boiler operating times based on the difference between the set temperature and the room temperature. The smaller the difference between these tem-peratures the shorter the boiler ignition time will be compared to previously.

AUTOMATIC ADVANCE functionThe TH350 self-adjusts so as to provide the desired temperature at the pre-selected time.

Boiler ignition and shutdown setting with 15 minute precisionIn automatic operating mode the TH350 can ignite or shut-down the boiler on the half or quarter of each hour, thus allowing for more pre-cise management of room comfort programmes and substantially optimising boiler energy con-sumption.

3

+3°C

–3°CPI

+3°C

–3°CPI

+3°C

–3°CPI

+3°C

–3°CPI

Page 4: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

4

The TH350 programmable thermostat is made up of:main unit

Supports

Calibration of temperature measurementIf the TH350 is not properly installed (e.g. installed near a heat source), temperature measurement may be incorrect or may not correspond to the actual temperature.To solve this problem, it is possible to calibrate the reading to within ±3°C and in so doing optimise comfort and consumption.

Easy and complete daily/weekly 3-level pro-grammingWith the TH350, temperatures for any time of any day of the week can be programmed in a simple and intuitive manner. Just a few buttons are used to set the hourly temperature while at the same time providing constant on-screen monitoring of programming progress.

Common domestic installation switch sur-round compatibilityABB: Series ELOS;AVE: SISTEMA 45, Series 44, Series BANQUISE;BTICINO: Series LIVING INTERNATIONAL, LIGHT, LIGHT TECH, AXOLUTE, LUNA, LIVINGLIGHT (air, quadre tonde);GEWISS: Serie PLAYBUS, SYSTEM, CHORUS;LEGRAND: Series VELA, CROSS;VIMAR: Series PLANA, IDEA, EIKON, ARKÉ;

+3°C

–3°CPI

+3°C

–3°CPI

+3°C

–3°CPI

A

C

B

D

Page 5: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

5

Adapter blanking fittings(2 white, 2 anthracite grey and 2 aluminium grey)

Back-box

Fixing screws

Front cover(1 white, 1 anthracite grey and 2 aluminium grey)

Page 6: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

6

4

21

3

65 8 9 111213 14 15

10

16

7

18192022 21 17

1

23

Page 7: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

7

SYMBOLS AND EXTERNAL CONTROLS (see fig. 1)

ATTENTION. To turn on the backlight simply press any key. To enter one of the selected functions (e.g. setting the clock, etc.) the appropriate button will need to pressed twice. The backlight stays on for 15 seconds after the last press of a button.

INFORMATION DISPLAYED1 0 ÷ 23 Program display for the hours..

The flashing cursor indicates the hour corre-sponding to the clock time.

2 Temperature range T1.

3 Temperature range T2.

4 Temperature range T3.

5 1÷7 Select the day.

6 Battery charge status.

7 Digital clock.

8 System bypass.

9 All-purpose programme activation.

10 Start-up and shut-down delay periods.

11 Manual operating mode.

12 Remote activation.

13 Protection against frost.

15 COOLING programme. When the cooling system is in operation this icon is

animated.

15 HEATING programme.

When the heating system is in operation this icon is animated.

16 Digital clock.

17 Button to increase temperature, time, etc.

18 Button to select MANUAL or AUTOMATIC oper-ating mode.

19 Temperature sensor.

ATTENTION. Avoid touching the sensor so as not to distort the temperature reading.

20 Tab for extracting the main unit of the thermo-stat from the back-box.

21 ALL-PURPOSE or MANUAL TIMER-CONTROLLED programme activation button.

22 Button to decrease temperature, time, etc.

23 When this warning appears, it means that the batteries are exhausted .

Page 8: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

8

1

L

12

L

24 25 26 27 28 29 30 31

2

Page 9: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

9

INTERNAL CONTROLS

To access the internal control buttons extract the tab L and pull the main unit of the thermostat forwards until it is blocked as indicated in fig 2.

24 R Reset.

25 Setting the clock and the start-up and shut-down delay period.

26 P Temperature programming in the three ranges T1, T2, T3.

Setting of operating parameters.

27 COOLING ( ) HEATING ( ) or OFF MODE programme selection.

28 0÷23 Decrease of the hour within the ‘Daily’ programme display.

29 0÷23 Increase of the hour within the ‘Daily’ programme display.

30 1÷7 Select the day.

31 C Copy programme.

Page 10: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

10

19 - Overall number of system operating hours . . . . . 39

20 - Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

21 - Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

22 - Battery replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

23 - Technical characteristics. . . . . . . . . . . . . . . . . . . . . . . . 45

CONTENTS

Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page

1 - Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2 - Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3 - Setting the clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

4 - Heating, cooling and system OFF programming 22

5 - Pre-memorised programmes. . . . . . . . . . . . . . . . . . . 22

6 - Daily programme temperature personalisation 23

7 - Temperature level personalisation for the heating program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

8 - Temperature level personalisation for the cooling program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

9 - ALL-PURPOSE programme . . . . . . . . . . . . . . . . . . . . . 27

10 - Manual operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

11 - System bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

12 - Frost protection function. . . . . . . . . . . . . . . . . . . . . . . 30

13 - Manual timed program . . . . . . . . . . . . . . . . . . . . . . . . 31

14 - System ignition and shut-down delay timing adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

15 - Temperature measurement calibration . . . . . . . . . 34

16 - Automatic advance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

17 - Thermal differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

18 - Proportional-Integral programming . . . . . . . . . . . . 36

Page 11: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

11

1 - INSTALLATIONInstall the unit in a position which is suitable for correct room temperature measurement for example on an internal wall. Avoid installation in niches, behind doors or curtains, or near heat sources.The TH350 is designed to be installed within a 3 module recessed back-box having a depth of 50mm. Proceed as follows:• Pull the tab L forwards. The main unit of the thermostat

will follow until it is blocked by two lateral stop tabs (3). Press the lateral tabs marked by the symbol (fig. 4) and extract the main unit of the thermostat completely.

• Insert 3 alkaline LR03 penlight AAA 1.5V batteries within the housing. Make sure the poles face the right way as shown on the bottom of the housing (fig. 5).

L

1

3

L

1

4 5

Use only ALKALINE batteries

Page 12: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

12

ATTENTION. Inserting the batteries the wrong way round could damage the unit. Once these steps have been carried out correctly the symbols shown in figure 6 will appear on the display.

Choose the support (A, B, C or D) and front facing cover as a function of the surround to be fitted. To remove the front cover proceed as indicated in figure 7.

76

Page 13: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

13

8

10

9

11

BTICINO (Light Series, Light Tech Series, Living International Series)

VIMAR (Plana Series, Eikon Series)

LEGRAND Vela Series (Vela Quadra, Vela Tonda), Cross Series

Support A Support A

Support BSupport B

GEWISS Playbus Series (Playbus, Playbus Young)

AVE (Banquise Series, SISTEMA 45)

VIMAR Idea Series (Idea, Idea Rondò)

Page 14: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

14

ABB (Elos Series)

GEWISS (SYSTEM Series)

BTICINO (Axolute Series, Luna Series)

BTICINO (Livinglight Quadre)

VIMAR (ARCHÉ Series)

BTICINO (Livinglight Tonde)

GEWISS (CHORUS Series)

12 13

14 15

Support B

Support C

Support B

Support C

Page 15: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

15

AVE (44 Series)

BTICINO (Livinglight AIR)

Support D

2

117

16

The trade names Playbus, Playbus Young, System e Chorus are the property of GEWISS S.p.A

The trade names Light, Light Tech Livinglight, Axolute, Luna e Living International are the property of BTICINO S.p.A;

The trade names Plana, Idea, Eikon, Idea Rondò e Arké are the property of VIMAR S.p.A;

The trade names Vela, Cross are the property of LEGRAND S.p.A

The trade names Banquise SISTEMA 45 e serie 44 are the property of AVE S.p.A

Il marchio Elos is the property of ABB S.p.A

Should the necessity arise to change the support then proceed as indicated in fig. 17.

Page 16: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

16

18

3 module recessed back-box

Back-box Support

L

Adaptors Main unit Support

Page 17: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

17

19

• Electrical connections are to made within the back-box terminal block as indicated in either diagram 20 or 21.

• Paying attention to the UP direction indication use the screws supplied to mount the unit to the back-box (fig. 19).

• Push the main unit of the thermostat all the way to the back and then fit the surround. Insert the locking tab L.

2 - ELECTRICAL CONNECTIONSThe wiring will depend on the type of equipment to be controlled by the thermostat: refer to the diagram in fig. 20 or 21.

KEY

Mains power supply wiresN = neutralL = live

Relay contactsC = commonNA = normally open contactNC = normally closed contact

NCNA C12

U1

LN

TH350

20

LOAD

Page 18: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

18

NCNA C12

LN

TH350

U2

M

LOAD

OPEN

CLOSED

21

Remote control inputs1 input2 input

LoadsU1 = boiler, circulation pump, solenoid valve, etc.U2 = motorised valve

NOTE. For connection details, refer to the technical docu-mentation of the device to be controlled.

Page 19: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

19

Page 20: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

20

22

23

24

25

3- SETTING THE CLOCK3.1- Remove the main unit of the unit.3.2- Press the button twice (fig. 22).The first press of the button simply activates the back-light.The minutes digits flash.3.3- Press button or until the correct value for the minutes is reached (fig. 23).3.4- Press button (fig. 24).The hour digits flash.3.5- Press either button or until the correct value for the hour is reached (fig. 25).3.6- Press button (fig. 26).The indicator for the days of the week flashes.3.7- Press button or until the correct value for the minutes is reached (fig. 27).3.8- Press button to end the procedure for setting the time and day (fig. 28).The colon between the hours and minutes flashes to confirm

Page 21: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

21

the operation is complete.If no button is pressed for 15 seconds, the unit automati-cally exits this procedure, saving the last setting.3.9- Reinsert the main unit of the thermostat.Note. Each time buttons or are pressed the numbers on the display decrease or increase by one. When pressed and held down the numbers on the display will scroll slowly for the first five seconds, and then more quickly.26

27

28

Page 22: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

22

4 - HEATING, COOLING ANDSYSTEM OFF PROGRAMMINGPress button once to activate the cooling pro-gramme (fig. 29) press the button twice to turn the system OFF (fig. 30).Whenever the icon is visible it confirms that TH350 system control has been bypassed.For 5 seconds the room temperature reading disappears to be replaced by .Press the once again. The heating programme will restart.

5 - ALL-PURPOSE PROGRAMME5.1 - HEATING PROGRAMMEFor easier use a heating programme has been mem-orised within the TH350 with the temperature trend shown in figure 31 from Monday to Friday (1÷5) and in figure 32 for Saturday and Sunday (6 and 7), where the fixed temperature levels are:Range T1 16 °CRange T2 18 °CRange T3 20 °C

29

30

31

Page 23: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

23

5.2 - COOLING PROGRAMMEThe memorised cooling programme includes the tem-perature trend shown in figure 33, where the fixed tem-perature levels are:Range T1 24 °CRange T2 26 °CRange T3 28 °C

If the pre-memorised programmes correspond to your needs then the TH350 will not require further programming and will ready tor immediate operation. To personalise the built in programmes proceed as outlined in chapters 6, 7 and 8.

6 - DAILY PROGRAMME TEMPERATUREPERSONALISATION6.1- Remove the main unit of the unit.6.2- Use buttons 1÷7 to move the day indicator to posi-tion 1 (Monday) (fig. 34).The parentheses for the selected day flash.6.3- Use buttons 0÷23 to move the flashing indicator

to hour 0 on the Daily programme graphic (fig. 35).Note. When this button is used, the information on the display changes as follows:a) The clock shows the hour indicated by the flashing segment . The colon between the hours and minutes does not flash.b) The temperature shown is the value of the selected level at the time indicated by the flashing segment.

34

32

33

Page 24: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

24

35

36

37

6.4- Use button or (fig. 36) to select the desired temperature range. Then press button 0÷23 to go to the next hour and select the desired temperature in the same way (fig. 37).Continue in this fashion until hour 23 is reached. Programming for Monday is now complete.6.5- If the same programme is also to be used for the following day(s) press button C (fig. 38) The programme will automatically be copied for those days as indicated by the corresponding segment.6.6- To programme subsequent days differently, advance the day using button 1÷7 and repeat the same procedure as set forth in point 6.4 (fig. 39).6.7- Once programming is complete, in order to go back to the current day and time press button (fig. 40); In any case, this will happen 10 seconds after the last action. Any programming task can be performed at any time.Hourly programming is saved to permanent memory.

38

Page 25: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

25

To reset the default parameters, see chapter 21 (Reset).6.8- Reinsert the main unit of the thermostat.

7 - TEMPERATURE LEVEL PERSONALISATION FOR THE HEATING PROGRAMME7.1- Remove the main unit of the unit.7.2- Make sure that the unit is in AUTOMATIC mode.7.3- Check to see that the heating symbol is displayed. If not then press button (fig. 41).7.4- Press button P (fig. 42).The temperature range for T1 will be displayed and in place of the current time the symbol together with the value of the temperature assigned to the T1 temperature range (set in memory at, 16°C).

41

39

40

42

Page 26: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

26

43 44

7.5- Use buttons or (fig. 43) to set the desired tem-perature for T1.7.6- Press button P to confirm the temperature shown on the display and pass on to the next temperature level (fig. 44).Note. The value assigned to each temperature range is limited to the values of the range just above or below. For example, if range T3 corresponds to 20°C and range T1 corresponds to 16°C, the value for range T2 can only vary between 16.1°C and 19.9°C. If a different temperature range for T2 is required, for example 21°C, then the range for T3 must be set at 21.1°C.7.7- To change the other temperature ranges repeat the steps described at points 7.4 and 7.5.The entire graph for the ‘Daily’ programme reappears to confirm that programming of the temperature ranges has been completed.

10 seconds after the last action the unit exits the proce-dure and accepts as valid the data inserted up to that moment.7.8- Reinsert the main unit of the thermostat.

Page 27: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

27

8 - TEMPERATURE LEVEL PERSONALISATION FOR THE COOLING PROGRAMMEExtract the main unit of the thermostat. Select cooling mode . Then set the desired temperature levels in the same manner as set forth from point 6.3 on. Reinsert the main unit of the thermostat.

9 - ALL-PURPOSE PROGRAMMEThe unit includes an all-purpose programme mode that can be used when on holiday and so on. It may be acti-vated at any time of the current day and remains active for the rest of that day. It can also be reserved for use on any day of the week.The programme stored in permanent memory features the preset profile for Sundays (7), but it can be custom-ised. To activate this programme for the current day, proceed as follows.9.1- Make sure that the unit is in AUTOMATIC operating mode.

4645

9.2- Press button (fig. 45).The symbol confirms that the programme has started.9.3- Complete the personalisation of the system as out-lined in paragraphs 6.3 and 6.4.At midnight the TH350 will return to automatic operating mode.9.4- To exit the ALL-PURPOSE programme and return to AUTOMATIC operating mode press the either button

or .If the ALL-PURPOSE programme is to be reserved for a day other than the current one, proceed as follows:9.5- Make sure that the unit is in AUTOMATIC operating mode.9.6- Remove the main unit of the unit.9.7- Use buttons 1÷7 to move the indicator to the posi-tion of the chosen day (fig. 46).In place of the clock, the current hour will be displayed. For example, at 16.25 the display will reveal 16:00.

Page 28: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

28

47

48

49

9.8- Press button (fig. 47).The symbols appears confirming that the programme for that day has been saved.9.9- Complete the personalisation of the system as out-lined in paragraphs 6.3 and 6.4.9.10- Press button or wait 10 seconds for the thermo-stat to return to AUTOMATIC mode.At 0.00 on the selected day, the programme will be activated.To cancel a specific programmed event move the indica-tor to the corresponding day using button 1÷7 and then press button .To return to AUTOMATIC operating mode for the current day press button (fig. 48). This will happen in any case 10 seconds after the last action. The all-purpose programme expires at the end of the day9.11- Reinsert the main unit of the thermostat.

10 - MANUAL OPERATIONIf a temperature that is different than the programmed one is required but without modifying the set pro-gramme then MANUAL operating mode can be accessed by pressing button (fig. 49). The event graphic will disappear from the display. The value of the previously set temperature will now be dis-played which can be changed as required using buttons

and (fig. 50) (The unit's default temperature is 20°C).

Page 29: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

29

52

50

51

After about 5 seconds from the last operation, the room temperature appears.In MANUAL operating mode, any temperature can be chosen between 2°C and 35°C. The newly set temper-ature will be maintained until further adjustments are made or until a different operating mode is selected.

11 - SYSTEM BYPASS System bypass is useful during cleaning, maintenance work or when absent, etc. The unit simply functions as a clock and room thermometer.11.1- Remove the main unit of the unit.11.2- Press the button twice (fig. 51).The selection made is confirmed by the symbol activated.The set temperature reading changes to . After about 5 seconds from the last operation, the room tem-perature appears.11.3- Press the button once to return to the heating programme (fig. 52). Press the button twice to return to the cooling programme (fig. 53).11.4- Reinsert the thermostat main unit.

Page 30: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

30

53

12 - FROST PROTECTION FUNCTIONEven if proportional-integral operating mode has been selected, in Frost Protection mode the temperature set for heating mode will be maintained but with differential control only.12.1- Remove the main unit of the unit. 12.2- Press the button twice and check that the symbol is displayed (fig. 54).12.3- Press the button. The presence of symbols and on the display confirms frost protection mode. The display shows the default frost protection temperature (3°C) which will remain displayed for 5 seconds (fig. 55).12.4- Press the or button to select any temperature between 3°C and 16°C (fig. 56).If a temperature below 3°C is set then the system will return to SYSTEM BYPASS mode.The symbol confirms the return to system bypass mode (fig. 57).

54

55

56

Page 31: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

31

57

58

59

By pressing button (fig. 58) it is possible to switch from FROST PROTECTION to AUTOMATIC heating mode.A reset in FROST PROTECTION or SYSTEM BYPASS mode will cause the system to restart in automatic heating mode.12.5- Reinsert the main unit of the thermostat.

13 - TIMED MANUAL PROGRAMIf a fixed temperature is to be maintained for a few hours or a few days (for example, to maintain a comfortable temperature for a longer period when unexpected guests arrive, or when an economical temperature is required during long periods of absence), MANUAL TIMED pro-gramme mode can be activated.Once the desired duration has been set, the device starts a countdown. When it reaches zero, the unit switches from MANUAL to AUTOMATIC mode, resuming the set programme.

Programming in terms of hours or days13.1- Make sure that the unit is in MANUAL operating mode.13.2- Set the desired temperature using buttons and .13.3- Press button once to set the hour (fig. 59), twice to set the days applicable (fig. 60).If the hours are being set then instead of the current time

will appear on the display. If the days are being set then will appear.

Page 32: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

32

62

61

60

13.4- Press buttons or until the desired number of hours or days from 1 to 99 is reached (fig. 61).The count of hours and days includes those when pro-gramming is performed. The remaining part of the hour and day when the operation is performed is therefore counted as one hour or as one day.Note. To return to AUTOMATIC operating mode before the programmed period expires press the button (fig. 62).+3°C

–3°CPI

14 - SETTING THE SYSTEM START-UP AND SHUT-DOWN DELAY PERIODIt is possible to delay system start-up and shutdown by 15, 30, or 45 minutes. To activate this function, proceed as follows.14.1- Make sure that the unit is in AUTOMATIC mode.14.2- Press buttons 0÷23 (fig. 63).The display indicates the value of the temperature set for the hour indicated on the current day.

63

Page 33: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

33

64

65

14.3- Press buttons 1÷7 (fig. 64).The display will show the value of the temperature set for the indicated time on the various days of the week.14.4- Press button (fig. 65) once, twice or three times within 10 seconds to set a delay time of 15, 30 or 45 min-utes and press it again to cancel the setting. For example, if a comfortable temperature is required for 7:00, the system can be set to start at 6:30.In this case, set the comfortable temperature for 6:00 with a delay of 30 minutes. The TH350 will activate at 6:30, maintaining until that time the temperature set at 5:00.The indication for the inserted delay is shown in auto-matic mode during the hour in which the delay has been programmed.The delay can be programmed for several different hours during the same day. The delay can also be applied to the remaining days of the week by means of the 1÷7 buttons.These settings are saved to permanent memory (see chapter 21, Reset).

66

Page 34: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

34

15 - ALIBRATION OF TEMPERATURE +3°C

–3°CPI

MEASUREMENTIf the TH350 is not properly situated (e.g. installed near a heat source), temperature measurement may be incor-rect or may not correspond to the actual room temper-ature. Use the buttons (backwards) or (forward) to change the temperature from 0.0°C (default setting) up to ±3°C in increments of 0.1°C.

Calibration of temperature measurement15.1- Make sure that the unit is in AUTOMATIC mode. 15.2- Press button P (fig. 66). On the display, in place of the hour, will be displayed and, in place of the indication for the temperature, there will appear .15.3- Press the buttons (forward) or (backwards) (fig. 67) until the desired value of correction is arrived at.This value will be saved to permanent memory, see chapter 21.

67 68

16 - AUTOMATIC ADVANCE

+3°C

–3°CPI

This function (only in heating mode) allows the thermostat to automatically adapt the system start-up time such that the desired temperature is arrived at in a timely manner. The advance is calculated as a function of the difference between the measured and set temperatures together with the data stored on the characteristics of the instal-lation and the building. The maximum advance available is three hours.

Example of operationAt 7.00 am the thermostat is set for a temperature of 20°C. If before 7.00 am. the ambient temperature is below 20°C the thermostat will advance system start-up so as to obtain 20°C at 7.00 am. Thanks to the self-learning mechanism, the programmable thermostat memorises the thermal parame-ters of the room in order to be more precise in reaching the temperature on subsequent days.

Page 35: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

35

70

69

71

Automatic advance selection.16.1- Make sure that the unit is in MANUAL operating mode.16.2- Press button P twice (fig. 68).On the display, in place of the hour, will be displayed and, in place of the indication for the temperature, there will appear .16.3 - To set the automatic advance press buttons (forward) or (backwards) (fig. 69). On the display, in place of the temperature, will appear.The automatic advance period will be saved to perma-nent memory, see chapter 21

17 - THERMAL DIFFERENTIALSelection of traditional adjustment system with

thermal differential adjustable between 0°C and 0.9°C. This adjustment system is recommended for systems with extreme variations in outdoor temperature that are especially difficult to control.

Differential adjustment system selection17.1- Make sure that the unit is in MANUAL operating mode.17.2- Press button P three times (fig. 70). On the display, in place of the hour, will be displayed and, in place of the indication for the temperature, there will appear .17.3- Press the P button once again (fig. 71). On the display, in place of the temperature the value of the set thermal differential value will appear.

+3°C

–3°CPI

Page 36: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

36

17.4- Press button (forward) or (backwards) (fig. 72) to modify this value as desired.During operation, setting the differential to 0°C provides compliance with a minimum start-up/shutdown time of one minute, regardless of the measured room tempera-ture.17.5- Press button P to exit programming.

18 - PROPORTIONAL-INTEGRAL +3°C

–3°CPI

PROGRAMMINGThis type of adjustment allows the programmable ther-mostat to reduce system running times as the room tem-perature approaches the set temperature, thus substan-tially reducing consumption while maintaining excellent comfort. It is possible to select from among three preset programmes depending on the type of system to control (P1, P2 e P3). Alternatively programme P4, which is com-pletely manual, can also be selected (Table 1 on page 39).

Integral proportional adjustment has the advantage of permitting the management of a wider variety of systems with respect to the setting of the thermal differential. It is especially suitable for underfloor and radiant systems. The difference between the set temperature and the ambient temperature is just a few tenths of a degree. This allows for more precise adjustment.

Proportional/integral programme selection (refer to table 1)18.1- Make sure that the unit is in MANUAL operating mode.18.2- Press button P three times (fig. 70). On the display, in place of the hour, will be displayed and, in place of the indication for the temperature, there will appear .18.3 - Pressing buttons (forward) or (backwards) (fig. 72) causes the integrated proportional control system to be selected.On the display, in place of the temperature, will appear (fig.73).

72 73

Page 37: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

37

75

74

Programme Cycle duration Minimum ON time Proportional Range Type of system

P1 10 minutes 1 minute 1.5°C Base for gas burner,convector heaters,

zone valves, aluminium radiators

P2 5 minutes 1 minute 1.5°C Electric radiators

P3 20 minutes 2 minutes 1.5°C Radiant or underfloor systems, cooling

P4 5-10-15-20-25-30-35-40 minutes from 1 to 5 minutes from 1°C to 3°C

Table 1

18.4 - Press button P instead of the time (fig. 74) will appear on the display.18.5- Press buttons (forward) or (backwards) (fig. 75) so as to select control system P1, P2, P3 or P4. Programmes P1, P2 and P3 are fixed programmes, where-as programme P4 can be completely programmed by the user.18.6 - If programme P1, P2 or P3, has been selected then in order to exit programming press button P.

76

Page 38: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

38

78

77 80

79

If programme P4 has been selected then press button P and in place of the hour the display will show . In place of the temperature will appear (fig. 76).18.7- Press buttons (forward) or (backwards) to select the desired cycle time from between 5, 10, 15, 20, 25, 30, 35 or 40 minutes (fig. 77).18.8 - Press button P (fig. 78). On the display, in place of the hour, will be displayed and, in place of the indication for the temperature, there will appear .18.9- Press buttons (forward) or (backwards) (fig. 79) to select the minimum start-up and shut-down times between 1 and 5 minutes.18.10 - Press button P (fig. 80).On the display, in place of the hour, will be displayed and, in place of the indication for the temperature, will appear.18.11- Press button (forward) or (backwards) (fig. 81) to modify proportional range between 1 and 3°C.

Page 39: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

39

81

82

18.12- Press button P to exit programming.All parameters for the proportional-integral setting are saved to permanent memory. See chapter 21.

19 - ACCUMULATED SYSTEM OPERATING TIMEThe TH350 features an hour-counter (up to 9,999), which records the system's accumulated number of operating hours for each temperature level.19.1- In order to visualise the stored data switch to MANUAL mode using the button (fig. 82), extract the main unit of the thermostat and press the C button (fig. 83).The display will reveal the total operating time for 5 seconds. To reset the counter to zero and start a new count, press the button while the figures are visible. The symbol will disappear after 5 seconds.19.2- Reinsert the main unit of the thermostat.

20 - REMOTE CONTROLBy connecting an appropriate interface to the terminal block connections 1-2 (fig. 19 or 20) it is possible to:- manually override the operation of the unit in manual mode,- activate a special programme at the end of that which was previously programmed.

- manually override the operation of the unit in manual mode. The set temperature refers to the last setting assigned to the unit in MANUAL mode.

83

Page 40: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

40

8584

This temperature will be maintained until the unit remotely receives a deactivation command at which point the TH350 will return to the state it was in before activation.It is possible to exit from remote MANUAL mode at any time by pressing the button.MANUAL mode activation can be recognised by the presence on the display of the and symbols (fig. 84).

- Activate a special programme at the end of that which was previously programmed.The TH350 stores two different programmes in memory, one for HEATING mode and one for COOLING mode. Upon activation of the remote command the programme for the current mode will be initiated.When the fixed-time manual program is activated remotely the symbol will appear.

If no other operations are performed then when the

program reaches its conclusion the TH350 will go back to the status it was in prior to activation.

To cancel remote control of the fixed-time manual pro-gram press the button. The default setting of fixed time manual mode is one hour at 20°C in HEATING mode and one hour at 24°C in COOLING mode (fig. 85).Note. When the program is activated remotely the time remaining within the hour or day will be counted as a full hour or day.

Fixed-time manual programming by remote control20.1- Make sure that the unit is in MANUAL mode and select the HEATING or COOLING mode to which the set temperature is to be applied.

20.2 - Set the desired temperature using the (forwards) or (backwards) buttons (fig. 86).

Page 41: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

41

86 89

87

20.3- Press button once to set the hour (fig. 87), twice to set the days applicable (fig. 89).If the hours are being set then instead of the current time

will appear on the display. If the days are being set then will appear.20.4- Press buttons (forward) or (backwards) until the desired number of hours (fig. 88) or days is reached (fig. 90) from 1 to 99. 20.5- To save this programme such that it can be activat-

88

90

Page 42: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

42

92

93

ed remotely press button .This setting cannot be verified by telephone.

21 - RESETOperating anomalies, repairs and other technical reasons may make it necessary to reset the unit.To reset the unit proceed as follows:21.1- Remove the main unit of the unit.21.2- Press button R (fig. 91).21.3- Reinsert the main unit of the thermostat.This operation does NOT delete any customised pro-grammes, which will be restored, along with other data, as soon as the unit is restarted (see table 2 on page 45).To reset all default settings, proceed as follows:

91L

1

94

Page 43: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

43

Data saved after a reset Data not saved after a reset

- Calibration temperature- Automatic advance selection- Differential or proportional integral mode- Differential temperature- Integral proportional programme- Cycle time- Minimum system start-up time- Proportional range- Heating/cooling mode- Winter temperature for fixed-time manual- Number of hours for winter fixed-time manual- Number of days for winter fixed-time manual- Summer temperature for fixed-time manual- Number of hours for summer fixed-time manual- Number of days for summer fixed-time manual- Ranges T1, T2 and T3 winter and summer- Summer and winter timer programme- Activation delay (15, 30 or 45 minutes) for each hour

- Minutes, hours, days of week- Automatic, manual, Frost Protection or OFF mode (1)- Manual temperature- Frost Protection temperature- Self-learning parameters for automatic advance

(1) When the thermostat is reset in FROST PROTECTION or OFF mode it will restart in AUTOMATIC HEATING mode.

Table 2

Page 44: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

44

97

- simultaneously press buttons , and 1÷7;- reset the unit. The TH350 will restart in AUTOMATIC HEATING mode (or COOLING, if reset in this mode).

22 - BATTERY REPLACEMENTWhen the indicator flashes on the display, it means that there is around 1 month left to replace the batteries (fig. 92). When the indication plus the symbol appear on the display, the unit is no longer operative and has set the heating and air-conditioning system to OFF (fig. 93). ATTENTION. Failure to replace the batteries in time may cause damage to the heating system (frost protection is not ensured).

To replace the batteries proceed as follows:22.1- Pull the tab L forwards. The main unit of the ther-mostat will follow until it is blocked by two lateral stop 96

L

1

95

Use only ALKALINE batteries

Page 45: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

45

83,5 42

98

tabs (fig. 94). Press the lateral tabs and extract the main unit of the thermostat completely (fig. 95).All symbols on the display will disappear.22.2- Insert 3 alkaline LR03 penlight AAA 1.5V batteries within the housing. Make sure the poles face the right way as shown on the bottom of the housing (fig. 96).After a few seconds the symbols will reappear on the display. Push the main unit of the thermostat all the way to the back and reinsert the tab L.Warning! Inserting the batteries the wrong way round could damage the unit. There will be approximately 2 minutes available for replacing the batteries. If the batteries are not replaced with the available period or if the reset button R is pressed (fig. 91) all settings will be lost. To restart the unit, proceed as described in chapter 3.ATTENTION. Inserting the batteries the wrong way round could damage the unit. The use of weak batteries may cause operating mal-functions. In this should happen then proceed as set forth in chapter 21.ATTENTION. Only clean the thermostat with a soft cloth dampened with water.

23 - TECHNICAL CHARACTERISTICS• Unit for domestic use.• Independently installed electronic device.• Display: LCD graphic backlit.• Power supply: 3 alkaline LR03 penlight AAA 1.5V batteries.• Autonomy: over 1 year.• Battery low warning.• Time available for battery replacement: approximately 2

minutes.• Relay: max. voltage 250 V, max. current 5A with resistive

load (2A with inductive load). Type of action: 1B-U. Available contacts: 1 NO-NC switch contacts.

Page 46: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

46

• Three operating modes: MANUAL, AUTOMATIC, SYSTEM BYPASS

• Daily programming of both heating and cooling.• Dual mode functionality: DIFFERENTIAL and

PROPORTIONAL INTEGRAL• Calibration of measured temperature.• Automatic advance for reaching the set temperature.• Remote activation.• System operating hours count from 1 to 9,999.• The possibility of timer-controlled manual operation.• Range of adjustment: from +3 to +35°C• Temperature levels: three, programmable between +3°C

and +35°C• Frost Protection temperature: adjustable between +3°C

and +16°C.• Programming: a temperature level for each hour or each

day of the week which can be extended to two levels by setting the start-up/shutdown delay time.

• Room temperature measuring interval: 15 seconds:• Thermal differential: adjustable from 0°C to 0.9°C• Reading resolution: 0.1°C.• Displayed reading range: from 0°C to +40°C• Precision: ≤ ±0.3°C.• Class A software.• Degree of pollution: 2.• Impulse voltage: 4 KV.• Maximum control unit temperature: 40°C.• Protection rating: IP30.• Class II electrical insulation. Use only ALKALINE batteries

• Operating temperature: from 0°C to +40°C• Dimensions: see figure 98.

Page 47: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

47

DISPOSAL

Do not litter the environment with packaging materials: make sure it is disposed of according to the regulations in force in the country where the product is to be used.When the equipment reaches the end of its life cycle, avoid discarding it within the environment.The equipment must be disposed of in compliance with current regulations, recycling its component parts wherever possible.Components that qualify as recyclable waste feature the relevant symbol and material acronym.

Page 48: TH 350 - bpt.it 24806610 13-03-13.pdfTH 350 INSTRUCTIONS FOR USE TH350E 24806610 13-03-13. 2 Congratulations on the purchase of this TH350 thermostat. For best performance and to enable

TH35

0E 2

4806

610

13-0

3-13

BPT S.p.A. a Socio UnicoVia Cornia, 133079 Sesto al [email protected]