THE ROCK SOLID SOLUTION TO UNEVEN FLOORS Level-Right ® Self-Leveling Floor Underlayment is a specially formulated, high-strength cementitious underlayment that can handle any floor leveling challenge — often without shotblasting or scarifying. Level-Right is poured over precast or cast-in-place concrete, terrazzo, ceramic, quarry, marble tile, old vinyl tile, and tile adhesives — providing a level, smooth surface. Hand troweling and hand finishing are unnecessary. Level-Right accepts practically any floor covering. With Level-Right there is no extensive curing time. Ceramic tile can be thin set within 2 to 4 hours. Other floor goods can be installed once Level-Right passes a moisture test. FEATURES/BENEFITS Pre-blendedmixofhighstrengthcementsandspecialadditives Waterresistant Poursoverconcreteaswellasoldfloorgoodsandadhesives Idealforlargeprojectsorsmallrepairjobs Nospecialprepping,removalofoldfloorgoods,orhand finishing required Setsfast,canbewalkedonwithintwotofourhours Compressivestrengthsupto5,500psi(37.9MPa) •Canbefeatheredged Testedatthemanufacturingplantandthejobsitetomeetour stringent quality assurance requirements Contains recycled materials GREENGUARD and GREENGUARD Gold Certified LEVEL-RIGHT Alwaysa“Green”BuildingMaterial LEVEL-RIGHT ® THE FAST, COST EFFECTIVE FloorlevelINGSySTeM

Upload: dinhtuyen

Post on 10-Jul-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

The Rock Solid SoluTion To uneven FlooRSlevel-Right® Self-leveling Floor underlayment is a specially formulated, high-strength cementitious underlayment that can handle any floor leveling challenge — often without shotblasting or scarifying.

level-Right is poured over precast or cast-in-place concrete, terrazzo, ceramic, quarry, marble tile, old vinyl tile, and tile adhesives — providing a level, smooth surface. hand troweling and hand finishing are unnecessary. level-Right accepts practically any floor covering.

With level-Right there is no extensive curing time. ceramic tile can be thin set within 2 to 4 hours. other floor goods can be installed once level-Right passes a moisture test.

FeATuReS/BeneFiTS•����Pre-blended�mix�of�high�strength�cements�and�special�additives•����Water�resistant•���Pours�over�concrete�as�well�as�old�floor�goods�and�adhesives•���Ideal�for�large�projects�or�small�repair�jobs•���No�special�prepping,�removal�of�old�floor�goods,�or�hand�

finishing required•���Sets�fast,�can�be�walked�on�within�two�to�four�hours•���Compressive�strengths�up�to�5,500�psi�(37.9�MPa)•��Can�be�featheredged•���Tested�at�the�manufacturing�plant�and�the�job�site�to�meet�our�

stringent quality assurance requirements• contains recycled materials• GReenGuARd and GReenGuARd Gold certified

level-RiGhTAlways�a�“Green”�Building�Material

level-RiGhT®

The FAST, coST eFFecTive Floor�levelING�SySTeM

For more info: 800-356-7887�• email: [email protected] www.MaxxonCorporation.com

Another superior product from: Maxxon® Corporation • 920 Hamel Road • P.O. Box 253 Hamel, MN 55340 USA • 763-478-9600 • Fax: 763-478-2431

MADE IN THE USA

©2014 Maxxon Corporation. All Rights Reserved. Levl-Right and associated logos are registered trademarks of Maxxon Corporation, Hamel, MN, USA. Printed in the USA. #62030, TA504-5977, 10/14.

TechnicAl dATA

LEED Certification ....May�help�contribute�toward�earning�points,� see�www.MaxxonCorporation.com

Ul�er�8477-01

Flexural Strength ......................1,260�psi�(8.7�MPa)�28�daysASTM�C348

Dry Density .........................approx.�125�lbs/ft3�(2,002�kg/m3)

VOC Emissions .......................... GReenGuARd Gold certified

Code Listings.....................�ICC-eS�evaluation�report�eSr-2540

Tensile Strength ............................720�psi�(5.0�MPa)�28�daysASTM�C190

Compressive Strength ... Typical:�3,000�psi�(20.7�MPa)�3�daysModified�ASTM�C109� 4,500�psi�(31.0�MPa)�7�days � 5,500�psi�(37.9�MPa)�28�days

Fuel Contribution ............................................................. 0Smoke Density ................................................................. 0Flame Spread .................................................................. 0

Fire Performance ASTM�e84

FiRe RATinGSUL Design

ULC Design

I530 L003L201

L511L512M500

M501M503M514

M520M521

G230G516G524G551G553G560G561G563G566G574J917J919J920J924J927J931J957J958J991J994L006L201L202L206

L208L209L210L211L212L501L502L503L504L505L506L507L508L509L510L511L512L513L514L515L516L517L518L519

L520L522L523L524L525L526L527L528L529L530 L532L533L534L535L536L537L538L539L540L541L542L543L545L546

L547L549L551L552L556L557L558L560L562L563L564L565L567L569L570L571L573L574L576L577L579L581L583L585

L588L589L590L592L593M500M502M503M504M505M506M507M508M510M511 M513M514M515M517M518M519

LEED® INFORMATIONFor information regarding how

level-Right may contribute toward points for�leeD�project�contribution,�contact�

your Regional Representative at�(800)�356-7887�or�visit�

www.maxxon.com/go_green.

FiRe/Sound RATinGSEvaluation Reports - Meeting fire and sound code together

Accepted by local building officials for fire and sound code compliance, Evaluation Reports are technical reports which verify that specific products meet the following code requirements and warrant regulatory approval. Minimum code requirements: Sound - 50 STC/IIC, Fire - I Hour

International Code CouncilICC ESR #2540 For the following assembly types:

Additional ICC ES Reports: ESR #1141, ESR #1153, ESR #1774

Underwriters Laboratory InternationalUL ER #8477-01 For the following assembly types:• Parallel Chord Truss• 2x10 Wood Truss

• I-Joist• Hambro

• Steel Joist• Precast Concrete

• Parallel Chord Truss• 2x10 Wood Truss

• I-Joist• Steel Joist

• Precast Concrete

Gypsum Wallboard

Steel or Wood Stud and Plate

Level-Right®

Level-Right®

Sealed Joint

Precast or Poured Concrete

Gypsum Wallboard

Steel or Wood Stud and Plate

Carpet, Tile or Other Floor Goods

Existing Uneven Concrete

Gypsum Wallboard

Steel or Wood Stud and Plate

Level-Right®

Level-Right®

Sealed Joint

Precast or Poured Concrete

Gypsum Wallboard

Steel or Wood Stud and Plate

Carpet, Tile or Other Floor Goods

Existing Uneven Concrete

deTAil dRAWinGS

PrePArATIoN concrete subfloors must be fully cured, moisture free and have no efflorescence. The substrate surface shall be clean, dust�and�contaminant�free.��Cracks�should�be�filled�with�a�crack�filler�or�an�elastomeric�compound.��Plumbing�or�electrical�penetrations�should�be�packed�with�insulation�and�sealed. no air movement, windows must be closed and no direct sunlight during the pour.

TeSTinG For level-Right, field testing must be performed in accordance�with�modified�ASTM�C109�using�2"�x�2"�(50�mm�x�50�mm)�cube�molds.�Before�independent�sampling,�contact�the�Maxxon�Quality�Control�Department�to�ensure�that proper procedures are followed.

lIMITATIoNS 1.�Do�not�pour�level-right�where�the�floor�temperature�is�less�than�50�°F�(10�°C)�or�greater�than�100�°F�(37.7�°C).�2.�Protect�the�poured�mortar�from�wind�and�sun,�and�from�freezing�temperatures�for�the�first�72�hours.3.�level-right�cannot�resist�stresses�caused�by�structural�movement.4.�The�structural�subfloor�and�floor�joist�must�comply�with manufacturers’ maximum span criteria. Typically a deflection�limitation�of�l/360�is�adequate�for�Maxxon�underlayments. Some floor coverings such as marble, stone, travertine, and ceramic tile may require a stiffer floor�system.�Maxxon�Underlayments�are�non-structural�and therefore cannot be expected to reinforce structurally

ProDUCT�SUPPorT Additional product literature,CSI formatted specifications and information are available upon request. For special applications, contact Maxxon Corporation.

WARRAnTy Maxxon Corporation warrants Level-Right® to be free from manufacturing defects as defined in this warranty. Manufacturing defects are considered to be those defects that occur due to the quality of the ingredients or from the manufacturing process itself. This warranty does not include labor costs and other costs or expenses associated with the removal or installation of Level-Right.Because Maxxon Corporation does not perform the actual installation, it cannot be held responsible for the results of the application. Maxxon Corporation specifically disclaims

problems that occur due to weather conditions, structural movement, structural design flaws, and application techniques.This warranty is in lieu of all other warranties expressed or implied including the warranty of merchantability and fitness of purpose and of all other obligations or liabilities on Maxxon Corporation’s part. Maxxon Corporation neither assumes nor authorizes any person to assume for Maxxon Corporation any liability in connection with the sale and installation of Level-Right.

dRyinG condiTionS The general contractor must provide and maintain correct environmental conditions to keep the building clean and dry, and protect against infestation of moisture from a variety of potential sources. Moisture can be introduced by other trades through spillage, tracked

in mud and rain, plumbing leaks, etc. Often stored in damp conditions, building products may arrive on site laden with moisture that releases after installation. Outside sources such as rain, snow, wind, etc. can also increase moisture levels.Controlling moisture levels in the building, through appropriate trade sequencing and prevention of potential damage by other trades, is the responsibility of the general contractor. The general contractor must supply mechanical ventilation and heat if necessary. These controls fall under the scope of work of the general contractor — not Maxxon Corporation or the Maxxon Underlayment installer.See Maxxon Building Conditions Guide for additional information.

deficient subfloors. The general contractor, architect, specifier, or�building�owner�should�make�necessary�allowances�for�expected live, concentrated, impact, and/or dead loads including the weight of finished floor goods and setting beds.5.�Additional�consideration�should�be�taken�for�concentrated/dynamic loads. u.S. building codes typically specify a uniform live�load�of�40�pounds�per�square�foot�for�residential�floor�designs. This load is intended to account for large loads that can occur in a building. in reality these loads are not uniform, but rather consist of items such as furniture and appliances that�actually�induce�concentrated�loads�far�exceeding�40�lbs�per sq ft. Rolling concentrated loads such as office chairs, wheel chairs, and motorized scooters add turning, twisting, repetition,�and�other�dynamics�which�should�also�be�taken�into�consideration. determining the appropriate structural design of�the�floor�is�not�the�responsibility�of�Maxxon�nor�the�Maxxon�applicator.6.�During�construction,�place�temporary�wood�planking�over�the�underlayment�wherever�it�will�be�subjected�to�heavy�wheeled or concentrated loads. 7.�level�-right�is�for�interior�use�only;�it�is�not�a�wearing�surface.8. level-Right will not structurally bridge over expansion joints,�saw�cuts�or�structural�cracks.�They�should�be�allowed�to continue through the level -Right. The architect or structural engineer�must�specify�expansion�joints�and�show�their�location�in areas that will receive hard surface floor goods, such as ceramic or marble tile and hardwood flooring.9.�For�deeper�fills,�call�Maxxon�Corporation�for�application�procedures.10.�For�applications�other�than�those�over�structural�concrete�call�Maxxon�Corporation�for�application�procedures.11.�Maxxon�Underlayments�are�“breathable”�and�not�a�vapor barrier. The general contractor, architect, specifier, or building owner shall test slabs-on-ground or elevated slabs for Mver�(ASTM�F1869-09)�or�rH�(ASTM�F2170).�If�the�Mver�or Rh of the concrete substrate exceeds the floor covering manufacturer’s respective requirements for the finished flooring system, the concrete must be treated with a moisture barrier, such�as�Maxxon�DPM�or�Maxxon�MvP,�before�installation� of level-Right.

Underwriters Laboratories Inc.® Listed