NOTE:
DEDUCT 25 SQ. FT. PANEL AREA
FROM LOOP 4 FOR ISLAND.
THE
FIR
EHO
USE
PR
OJE
CT
CH
ICA
GO
, IL
1
MANIFOLD LOOP # LENGTH
LOOP SCHEDULE
2
PANEL AREA
3
4
1
193 SQ. FT.188'-5"
51 SQ. FT.55'-7"
150 SQ. FT.147'-2"
338 SQ. FT.313'-2"
23
FIRST FLOOR PANEL LAYOUT
SCALE: 1/4" = 1'-0"
M-4
L-6
L-6
L-9
L-10
TUBING DROP
POINT
CUSTOM GROOVE
PLYWOOD OR
GROUT BED
FILLER (TYPICAL)
TRIM PANEL AS REQ'D
CUSTOM FIELD
GROOVE AS REQ'D
2
5
263 SQ. FT.272'-11"
6
87 SQ. FT.82'-9"
3
7
223 SQ. FT.219'-7"
8
265 SQ. FT.253'-6"
9
205'-11"
4
10
273'-4"
BATH
LOOP 6
1'-1
1 1
/2
"
3'-11"
1'-1
1 1
/2
"
3'-11"
FIELD TRIM EACH PIECE TO FIT DESIGNATED OPENING.
HALF COMBO
1/2 HORIZONTAL COMBO
WITH 2 HALF CURVES
1/2 HORIZONTAL
COMBO-BOTTOM
1/4 COMBO WITH 2
QUARTER CURVES
1/4 COMBO WITH HALF
CURVE
HALF COMBO
1/4 COMBO WITH 2
QUARTER CURVES
1/4 COMBO WITH HALF
CURVE
1/4 COMBO WITH 2
QUARTER CURVES
1/8 COMBO LRH
1/8 COMBO LLH
PANEL ITEM
NUMBER
PANEL ITEM NUMBER
MANUFACTURED GROOVES
TO ACCEPT PEX TUBING
NOTE:
ACTUAL PANEL SIZES MAY
DIFFER SLIGHTLY FROM CAD
DRAWING REPRESENTATION.
TOTAL ECOWARM PANELS TO BE DELIVERED:
STRAIGHTS: 109 EA.
COMBOS: 93 EA.
ECOWARM FLOOR PANEL NOTES:
1-STRAIGHT PANEL LENGTHS SHOWN ARE APPROXIMATE. FIELD
MEASURE AND CUSTOM CUT EACH PANEL TO FIT DESIGNATED
LOCATION. SEE INSTILLATION AND DESIGN MANUAL FOR
DETAILED PROCEDURES.
2-WHEN CALCULATING FIELD CUT COMBO PANELS DEDUCT FOR
SAW CUT WIDTH.
3-EXCESSIVE WASTE MAY DICTATE NEED TO UTILIZE MULTIPLE
SALVAGED PANEL PIECES (2" MIN.) TO FILL PANEL LOCATIONS.
4-THE LAYOUTS PROVIDED ARE BEST ESTIMATE ONLY. ALWAYS
REFER TO THE DESIGN AND INSTILLATION MANUAL FOR ALL
DESIGN AND INSTILLATION RELATED INFORMATION.
THE DESIGN AND INSTILLATION MANUAL SUPERCEDES ANY
LAYOUT NOTATIONS.
COMBINATION STRAIGHT
PANEL FIELD CUT
PANEL TYPES TO BE FIELD CUT FROM STRAIGHT AND COMBO PANELS
PANEL SIZES SHOWN ARE APPROXIMATE, FIELD MEASURE EACH OPENING AND CUSTOM CUT EACH PANEL TO FIT.
L-3
INDICATES MANIFOLD #
TUBE FLOW DIRECTION
LOOP #
PEX TUBING
MANIFOLD
LEGEND
TUBING FROM LOOP
DROP POINT
INSULATED TUBING
FROM ECOWARM
FLOOR PANEL EXIT (IN
WALLS, ETC.) TO THE
MANIFOLD LOCATION.