the future of paper chromatography in the wine industry due to … · 2017. 6. 29. · • malic...

19
The future of paper chromatography in the wine industry due to alternative methods Carien Coetzee SAWLA Workshop 26 May 2017

Upload: others

Post on 31-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • The future of paper chromatography in the wine industry due to alternative methods

    Carien Coetzee

    SAWLA Workshop26 May 2017

  • Paper chromatography

    Accuvin™Vinmetrica SC-

    50

    Enzymatic Spectrometric

    Analysis

    FTIRWinescan

    HPLC

    LOQ

    Time for analyses

    Hazards

    Cost per sample

    Instrument cost

    Ease of use

    Availability

    Simpler methods Complex methods

  • Kit contains• Wide mouth jar• Capillary pipettes• Chromatography papers• Chromatography solvent

    • Tartaric acid standard• Malic acid standard• Lactic acid standard

    Paper

    chromatography

  • Paper

    chromatography

    • Small sample volume• Limited training required• Readily available• Low cost• Kit only

    • 24 hours• Hazardous chemicals• Not quantitative• Interpretation subjective

  • Malic acid

    Lactic acid

    Paper

    chromatography

  • Kit contains• Sampler• Test strip• Colour chart

    Accuvin™

  • Accuvin™

    • Small sample volume• Limited training required• NOT Readily available ?• Low-medium cost

    • Quantitative• 4 minutes• No Hazardous chemicals• Interpretation subjective• Kit only

  • • Vinmetrica SC-55 Manometer • Malic Reagent set• Biopressure Agent Reaction Vials• 1 ‘check’ vial • 10 ml serological pipette• 15 ml conical tube• Plastic bulb pipette• 100 mL polypropylene beaker• Plastic Scoop

    • Distilled water• Microwave oven

    Vinmetrica

    SC-50

  • Vinmetrica

    SC-50

    • Small sample volume• Limited training required (more than previous)• Not Readily available ?• Low-medium cost

    • Quantitative• 30-60 minutes• No Hazardous chemicals• Need to acquire instrumentation + kit

  • • Spectrophotometer • Cuvettes • Micropipettes • Enzyme test kit (includes buffer solution, NAD,

    enzymes, standards)

    Enzymatic

    Spectrometric

    Analysis

  • Enzymatic

    Spectrometric

    Analysis

    • Small sample volume• Laboratory training required• Readily available• Low-medium cost per sample

    • Quantitative• 30 minutes• No Hazardous chemicals• Need to acquire instrumentation + kit

    Measure absorbance using a spectrophometer

  • Enzymatic

    Spectrometric

    Analysis

    • Auto analyzers are convenient, but costly to purchase✓ Eliminates analyst variation✓ Less labour intensive ✓ Small volume needed✓ Capacity for increased sample numbers ✓ Decrease in cost per sample

    • Skilled personnel • Periodic maintenance

  • • Foss Winescan / OenoFoss

    FTIR

    Winescan

  • FTIR

    Winescan

    • Winescan/OenoFoss is convenient, but costly to purchase✓ Eliminates analyst variation✓ Less labour intensive – very easy to use✓ Small volume needed✓ Capacity for increased sample numbers ✓ Decrease in cost per sample✓ Automization available

    • Skilled personnel • Periodic maintenance• Constant checks due to matrix effects

    • Small sample volume• Laboratory training required• Low-medium cost per sample

    • Quantitative• 1 minute• No chemicals• Need to acquire instrumentation

  • • HPLC, column and assorted equipment • Sample vials and caps • Filtration membranes and syringes • Acetonitrile, phosphoric acid, and distilled water • Filtration unit for reagents

    HPLC

  • HPLC

    • Skilled personnel • Periodic maintenance

    • Small sample volume• Laboratory training required• High cost per sample

    • Quantitative• 40 minutes• Potentially hazardous chemicals• Need to acquire expensive

    instrumentation

  • Paper chromatography

    Accuvin™Vinmetrica SC-

    50

    Enzymatic Spectrometric

    Analysis

    FTIRWinescan/OenoFoss

    HPLC

    Qualitative Semi-Quantitative Quantitative Quantitative Quantitative Quantitative

    LOQ n/a 0.03 g/L 0.1 g/L 0.05 g/L 0.001-0.05 g/L

    Time for analyses

    24 hours 4 min 30-60 min 30 min 1 min 40 min

    Hazardschemicals noxious,

    flamablenone irritant mildly corrosive none

    chemicals flamable, corrosive, irritant

    Cost per sample

    R7 R40-R50 R40-R50R320 (after instrument)

    R650 (after instrument)

    Instrument cost

    kit kit R2 000 R45 000 R1 200 000 R1 200 000

    Ease of use * * ** *** *** ****

    Availability **** * * *** *** ***

  • Paper

    chromatographyAccuvin™

    Vinmetrica

    SC-50

    Enzymatic

    Spectrometric

    Analysis

    FTIR

    WinescanHPLC

    The future of paper chromatography in the wine industry due to alternative methods

    ✓ Easy to perform✓ Readily available✓ Low cost

    • Useful for wineries: in-house checks• Can then confirm with accredited laboratory the completion of MLF• Not feasible in routine laboratories

    Not Quantitative Does it need to be?

  • [email protected]

    SAWLA Workshop26 May 2017