the leading multiprotocol intelligent fire panel - advanced · pdf fileand indication options...
TRANSCRIPT
The Leading Multiprotocol Intelligent Fire Panel
Tel: +44 (0)1670 707 111 Fax: +44 (0)1670 707 222
Email: [email protected] Web: www.advancedco.com
TouchControl is Advanced’s new touchscreen remote control terminal & repeater. It delivers network monitoring and control as well as active maps and zone plans, all in a package that enhances any architectural environment and is easy to install and configure.
TouchControl includes all the control and indication options you’d expect from Advanced, all managed via its unique 10” HD interface. For the first time there’s a fire system touchscreen that looks as good as it performs.
Fire Touchscreen. Remote Control Terminal. Active Maps.
To book a demo or for more info visit touchcontrol.advancedco.com
SSD970 TouchControl Advert A4-v9.indd 1 11/09/2015 14:11
Contents
The Standard in Fire Systems 4
The Unbeatable Multiprotocol Solution from Advanced 6
MxPro 5 8
MxPro 4 10
MxPro Panel Comparison 12
Advanced Networking 14
Dynamix Tools 15
TouchControl 16
AlarmCalm 17
Advanced360 18
AdSpecials 19
Project Leadership 20
MxPro Parts List 21
3
Tel: +44 (0)1670 707 111 Fax: +44 (0)1670 707 222
Email: [email protected] Web: www.advancedco.com
TouchControl is Advanced’s new touchscreen remote control terminal & repeater. It delivers network monitoring and control as well as active maps and zone plans, all in a package that enhances any architectural environment and is easy to install and configure.
TouchControl includes all the control and indication options you’d expect from Advanced, all managed via its unique 10” HD interface. For the first time there’s a fire system touchscreen that looks as good as it performs.
Fire Touchscreen. Remote Control Terminal. Active Maps.
To book a demo or for more info visit touchcontrol.advancedco.com
SSD970 TouchControl Advert A4-v9.indd 1 11/09/2015 14:11
The Standard in Fire Systems
Advanced is known all over the world for making the best quality, best performing fire systems.
We design ‘easy’ into all of our products. We make our software intuitive. We deliver fast, accessible support, training and service. Above all, we make it easy to rely on Advanced.
Fire Systems are in our DNA. Our people are among the most talented and experienced in the fire systems business. We train talented engineers and technicians every year. 25% of our business is dedicated to R&D. Our knowledge is unmatched, anywhere in the world and we’re determined to keep it there.
Our systems are protecting people and property in over 60 countries worldwide, in many of the most prestigious and challenging locations. We realise our growth comes from the strongest customer relationships. We stay friendly, flexible and reactive to your requirements and our customer service is consistently rated excellent.
We manufacture all of our panels in the UK to demanding quality standards and hold global approvals. We enjoy full ISO 9001 compliance across manufacturing and design.
Manufacturing and Quality
Admin
Customer Service and Support
R&D
Manufacturing and Q
ualityAdm
in
Customer Service and Support
R&
D
4
Welcome to the world of Advanced
5
The Unbeatable Multiprotocol Solution from Advanced
1. Choose your panel.
2. Choose your detector.
3. Choose your Installer.
Real freedom, Advanced quality.
6
TM
EN 54-2, 4 & 13
The multiprotocol market is driven by freedom. Specifiers want to choose the best performing panel and match it with the most appropriate detector range.
End users want freedom from expensive maintenance contracts and installers want to work with easy to use systems, free of restrictive agreements.
MxPro is the market-leading solution and delivers performance, choice and real freedom.
MxPro includes two panel ranges, the advanced MxPro 5 and the benchmark MxPro 4. Both come in 1-8 loop formats and are compatible with Apollo, Argus, Hochiki and Nittan protocols. MxPro is simply the best multiprotocol solution available.
We do not lock customers into an installer network. We design our panels to be easy to install, configure and operate, from single panel installations to 200 panel networks. We offer our installers full, free training and the most comprehensive customer support available.
We were the first panel manufacturer to offer a three year guarantee as standard but your MxPro system will last a lifetime. It’s a reliable, scaleable solution that can grow as your specification changes and we offer lifetime support.
7
Our Most Advanced Panel
MxPro 5 is our highest performance, analogue addressable fire panel and is fully approved to EN54 Parts 2, 4 and 13.
MxPro is the result of decades of fire alarm and detection experience and research and development involving installers, specifiers, consultants and end users across the world.MxPro 5 has been designed to offer industry leading power and performance. It packs more configuration, display, status and control options into its interface as standard than any other Advanced fire panel to date.
MxPro 5 utilises the latest technology making it significantly more powerful than the MxPro 4. Its processing power means it delivers more features than other panels, an advantage it will maintain for years to come.
Every MxPro 5 panel supports Advanced’s unbeatable networking capabilities as well as our Dynamix Tools fire panel software making it both easy to use and configure, from the smallest to the largest of sites with the most complicated cause-and effects.
Part 13 compliance ensures that a fire system will continue to perform to its maximum capability during a fire situation. Increased current in alarm conditions combined with a high resistance connection
(e.g. an incorrectly tightened screw in a sounder base), could prevent the sounders and beacons from operating on what would have incorrectly appeared to have been an acceptable ‘fault free’ installation.
Advanced’s MxPro 5 is one of the few EN54 Part 13 approved panels available. MxPro 5 continuously monitors all transmission lines for compliance, checking and reporting faults every minute of every day.
8
Why do I need Part 13?
Features• 1, 2, 4 or 8 loop formats• Up to 254 devices per loop
(protocol dependent)• Up to 2,000 fire detection
zones• Over 200,000 devices
per network• True peer-to-peer networking• Networkable up to 200 nodes• Supports intelligent remote
terminals, BMS interface, IP Gateway and I/O programmable I/O devices
• Built in oscilloscope, voltage and current meters
• Circuit monitoring from any panel or repeater
• On board or optional remote battery temperature sensor
• Direct USB and RS232 PC connections
• Advanced’s simple select and click programming and configuration
• Autolearn and Loop Detection• Quick start and protect -
a working system after an Autolearn
• Peripheral expansion built in• 20 built-in, fully
programmable LEDs• 4 programmable push buttons• 5,000 event log entries• Complete device history
from each panel• 200 programmable false alarm
management areas per panel• Programmable screen logo• Timed enablement of isolated
zones, input and output devices• Advanced logic delivering huge
configuration opportunities• Backward compatible
with MxPro 4 network• Compatible with Apollo
Discovery and XP95, Argus Vega, Hochiki ESP and Nittan Evolution protocols
• Approved to EN54 Parts 2, 4 and 13
• Advanced diagnostics includes ‘scope on board’
TM
EN 54-2, 4 & 13
• Single loop
• Small enclosure
• Maximum 7Ah internal batteries
• 20 programmable LEDs
• Optional programmable key switch
• Programmable Input
• Medium, Large and Deep enclosure options
MxPro 5 - 1 Loop
• One to four loops
• Large enclosure
• Maximum 17Ah internal batteries
• Up to 200 additional programmable LEDs
• Up to 8 programmable key switches or 4 plus printer
• Plexi-glass door option
• Deep and Extended enclosure options
MxPro 5 - 4 Loop
• Rack mountable control panels
• Additional 16U and 20U high IP55 enclosures
• Rack mount peripheral chassis plate, LED and switch card module options
• Dedicated Mimic door option
MxPro 5 - Rack Mount
• Four types available including;
− TouchControl touchscreen with active maps
− Remote Display Terminal
− Remote Control Terminal with additional Mute, Silence, Reset and Resound keys
− Remote Control Terminal with additional LED status indication, four programmable push buttons, Mute, Silence, Reset, Resound, Lamp Test and Evacuate Keys.
• Optional level 2 access enable key switch. (Not TouchControl).
• Integrated standard or fault-tolerant network interface with screen termination point
• Programmable display for up to 2,000 zones along with sector based controls
MxPro 5 - Remote Terminals
• One or two loops
• Medium enclosure
• Maximum 12Ah internal batteries
• Up to 50 additional programmable LEDs
• Up to 8 programmable key switches or 4 plus printer
• Plexi-glass door option
• Large and Deep enclosure options
MxPro 5 - 2 Loop
• Two to eight loops
• Extended enclosure
• Maximum 45Ah internal batteries
• Up to 200 additional programmable LEDs, 2 x switch cards or mimic
• Up to 8 programmable key switches or 4 plus printer
• Plexi-glass door and external battery box option
MxPro 5 - 8 Loop
• Integrated P-Bus as standard on all MxPro 5 panels
• Up to 32 expansion cards can be added to an MxPro 5 panel
• Peripheral expansion option cards include
− 4 way relay card
− 4 way sounder card
− 10 way monitored input card
− Conventional zone card (8 class B or 4 class A zones + 3 programmable relays)
− 16 way push button/48 LED card
− 16 way input/48 output (direct drive LED outputs)
− Fire and Fault Routing/Protection Card
− Redundant Controller
MxPro 5 - Integrated Peripheral Bus
9
The Benchmark Fire Panel
The industry workhorse, performing across the world, in all kinds of applications.
MxPro 4 is approved to EN54 Parts 2 & 4
MxPro 4 is a world-proven multiprotocol fire panel range. Built on Advanced’s well established Mx-4000 platform, it’s a fire system installed in 100,000s of locations worldwide, from single panel, single loop installations to large multi-panel networks.
The precursor to the MxPro 5, it offers uncomplicated operation as standard and can be expanded with a huge range of peripherals and accessories to meet most needs and configurations.
MxPro 4 utilises a simplified version of our Dynamix Tools fire system software allowing easy set up and management.
Features• 1, 2, 4 or 8 loop formats• Up to 254 devices per loop
(Protocol dependent)• Up to 1,000 fire detection zones• Up to 203,200 devices per
network• True peer-to-peer networking• Networkable up to 200 nodes• Supports intelligent remote
terminals, BMS interface, IP Gateway and I/O programmable I/O devices
• Circuit monitoring of local panel circuits
• Autolearn and Loop Detection• Simple Select & Click
programming • 1,000 event log entries
• Simplified logic delivers click and go configuration
• Built in voltage and current meters
• Quick start and protect – a working system after Autolearn
• Single area false alarm management facility
• Optional Peripheral Expansion Card
• Programmable logo on screen• Compatible with Apollo
Discovery and XP95, Argus Vega, Hochiki ESP and Nittan Evolution protocols
• Approved to EN54 parts 2 and 4
10
TM
BS EN 54-2 & 4
• One to four loops
• Maximum 17Ah internal batteries
• Maximum 38Ah internal batteries – deep enclosure
• Up to 200 additional zone fire LEDs
• Up to 8 programmable key switches or 4 plus printer
• Plexi-glass door option
MxPro 4 - 4 Loop
• Single loop
• Maximum 7Ah internal batteries
• Maximum 12Ah internal batteries - large enclosure
• Aperture for 20 zone fire LEDs
• Optional programmable key switch
MxPro 4 - 1 Loop
• Three types available including;
− TouchControl touchscreen with active maps
− Remote Display Terminal
− Remote Control Terminal with additional Silence, Resound, Reset and Evacuate Keys
• Optional level 2 access enable key switch
• Integrated standard or fault-tolerant network interface with screen termination point
• Programmable display for up to 1,000 zones along with sector based controls
MxPro 4 - Remote Terminals
• 8-way input card
• 8-way relay output
• Monitored shop unit interface
• Optional Peripheral Expansion card supports the following
− 4-way relay
− 4-way sounder
− General routing card
MxPro 4 - Peripherals
• One or two loops
• Maximum 17Ah internal batteries
• Maximum 38Ah internal batteries – deep enclosure
• Up to 200 additional zone fire LEDs
• Up to 8 programmable key switches or 4 plus printer
• Plexi-glass door option
MxPro 4 - 2 Loop
• Two to eight loops
• Maximum 2 sets of 38Ah internal batteries
• Aperture for up to 200 zone fire LEDs
• Up to 8 programmable key switches or 4 plus printer
MxPro 4 - 8 Loop
11
Panel ComparisonMxPro 4 MxPro 5
Hardware Features
Display Backlight Green backlit display
Manual contrast adjustment
White backlit display
Improved efficiency with programmable dimming options
Software driven contrast adjustment via menu
PC Connections RS232 USB, RS232
Peripheral Expansion Bus 1 loop – n/a
2-8 loop – requires additional optional circuit card
Built in as standard on all panels
Extended range of P-Bus option cards
Wiring Fault Monitoring EN54-2: Open circuit, short circuit
EN54-2: Open circuit, short circuit
EN54-13: Continuous checking for increases in resistance, (loose terminations), partial shorts etc.
Control Keys Reset, Mute, Silence/Resound and Evacuate Mute, Silence, Reset, LED Test, Resound, Evacuate and dedicated More Alarms buttons on control panels and large repeater
Configurable keypad repeat keys
Front Panel Push Buttons None 4 programmable function buttons on control panels and large repeater
Battery Charging Charger current and voltage can be viewed on local display
Built in battery temperature sensor
Charger current, voltage and temperature available from any display on a network
Built in or remote battery temperature sensor
Zone LEDs None as standard
Option 20 zone fire red LED card on 1 loop
Options for up to 200 red zone fire LEDs on 2-8 loops
20 integral red LED indicators included as standard on control panels and large repeater. Can be assigned to any fire zone or programmable for other uses.
Up to 200 additional LEDs with Large, Deep and Extended enclosures. (Up to 50 in Medium enclosure). Options include red, yellow and (bi-colour) red/yellow or green/yellow column format with slide-in labels.
Programmable Input None Dedicated monitored switch input as standard on all panels
Programmable Key Switch Inputs Requires additional optional key switch input card
Built in as standard on all panels
Printer Optional on-board printer with built-in battery pack
Optional on-board printer. No additional battery pack required. Integral paper feed button. Printer fault conditions displayed on panel, prints customer logo
Standards EN54-2 and 4 EN54-2, 4 and 13
Software Features
Independent General Event and Fire Event Logs
Yes – control panels only
Not on remote terminals
Yes – on all panels and repeaters
Any panel can be configured as a network-wide main event log
Event log entries 1,000 + 500 Fire 5,000 + 500 Fire
Additional logging for Investigation delays and any Enable/Disable actions
Timed Disable Options Permanent only Permanent or automatic timed re-enablement of any input or output device
Enable/Disable Inputs by zone • All Inputs
• All Inputs except Call Points
• Selected Inputs
• All Inputs
• Selected Inputs
• Only Automatic Inputs
• Only Manual Inputs
• All Other Inputs
Enable/Disable Outputs All Local Panel sounders, relays or individual outputs
Disable by Output Purpose
Configurable Disable Outputs Menu options include; Sounders, Relays, Beacons, Fire Routing, Fault Routing, Fire Protection, Pager, All or Selected
Disablement of outputs across network configurable by sector mask
Real Time Clock Yes - requires lithium battery Yes - no lithium battery required
Languages Supports Western European languages Supports multiple different character sets (code pages) and languages
12
MxPro 4 MxPro 5
Network Features
Max devices per network 188,800 200,000
Max nodes on network 200 200
Sectors 50 200
Maximum Fire Zones Displayed 250 1 loop
1,000 2,4 and 8 loop
2,000 on all panels
Programming Features
Independent Building Areas for False Alarm Management
Single area processing 201 areas per panel
Local or Global Alarm Acknowledgment facility
Zone LEDs No programmable options All LEDs fully programmable
PC configuration presented graphically
Primary/secondary activation
Buzzer Options No programmable options Smart latch of faults
Fault notification can resound daily
Service option to Inhibit by time clock
Programmable Input actions 19 22 - including new Supervisory, Fire Routing and Fire Protection confirmed + Alarm Acknowledgement actions
Output Purpose n/a Output purpose configurable
Output Ringing styles 20 40 - Output activation priority configurable
Zone Qualifiers 15 categories of zone qualifiers 24 categories of zone qualifiers
Logic statements 500 Logic lines – Programmable options –
• Inputs
• General Events
• Time Clocks
1,500 Logic lines – Programmable options –
• Inputs
• Any 2 inputs
• Zone qualifiers
• Any 2 zones
• General Events
• Time Clocks
General Events 10 categories 36 categories
Blocking Rules No options Programmable blocking rules – by General Event or Output Groups
Service and Diagnostic Features
Device History n/a For every device the time and date of the :-
• Last activation
• Last Test
• Last Disable
• Last Enable
• Date Created
On-board Digital Storage Scope n/a Yes
View Panel Voltages and Currents Available for local panel circuits only Available from any MxPro 5 repeater or panel on the network.
View Panel Status Local hardware and panel firmware version View status of all panel circuits across network
Firmware version of all internal hardware and peripheral devices can be viewed at the panel
Firmware updates Panel firmware flash upgradable All hardware flash upgradable via panel USB or serial port
Detector Status Information View drift information at local panel New Warning state allows any devices nearing drift contamination limits to be identified during routine servicing before a fault level is reached
Service tool Download device information Download device information
Extract Event log information
Download device History
View drift (contaminated) status of detectors
Network simulation and test facility
13
Advanced NetworkingOur high performance network technology works across the MxPro range delivering the easiest setup and best performing fire panel networks available.Advanced Networking allows all MxPro series control panels, remote terminals and network peripherals to be connected together using standard fire resistant two-core cable. It provides both the benefits of distributed intelligence and reduced installation costs whilst catering for the smallest two-panel network through to the largest 200 panel, wide-area, networked system. The network operates as a true peer-to-peer system and is therefore not reliant on a single ‘master’ panel to function. It allows information from any input or output device to be passed over the network and displayed on any MxPro control panel or remote terminal as required. Details include Fire, General Alarm, Pre-alarm, Fault, Control Inputs and Disablement as well as analogue values, test instructions and status information.
The zoning facility allows the networked system to share up to 2,000 zones giving non-confusing indication and allowing true peer-to-peer cross panel report, control and site-wide cause and effect functionality.
Simply adding and connecting a network card allows any MxPro control panel or remote terminal to be networked. Autolearning the devices, adding text and assigning the zone numbers allows a working and compliant fire system to be achieved easily. All other nodes on the system will be instantly aware of a panel as soon as it is given a valid network node address, allowing additional panels to be added at any time with a minimum amount of reprogramming.
All panels provide valuable diagnostic and status information and also have the facility to prevent the transmission of fires or faults during commissioning. For more complex systems, our Dynamix Tools software makes for easy configuration of complicated cause-and-effect, whilst all the configuration data is contained within one user-friendly network configuration file.
ipGateway
ipGateway provides a secure, remote internet connection to an Advanced fire system via a standard web browser. No special software is required.
The state of each device on the network is displayed and users can Enable/Disable zones, Enable/Disable devices, Reset, Mute, and Silence/Resound sounders on the network.
The ipGateway can also be configured to react to events on the network by sending emails or SMS messages to configured recipients.
PC-Net Graphical Control Software• Highly configurable to specific
system• Our graphical control software
monitors the entire fire system through site maps, text and icons
• Users can isolate by selecting icons and devices
• Fire panel controls include Mute, Silence, Re-sound, Reset, Disable/Enable and Evacuate
• Event reports and log with analysis features
Advanced BMSThe BMS Interface allows any MxPro system to interconnect and communicate with independent 3rd party BMS (building management systems) as well as PC based graphical control systems. This allows the fire system to be managed using existing fire or facilities management systems.
Physical connection to the external system is via a serial connection allowing the external BMS/Graphics systems to issue commands and receive information whilst the BMS interface handles all network traffic and event prioritisation. Multiple BMS interfaces can be connected to an AdNet network allowing independent connections to a wide range of control systems.
BMS
I/0
32x on boardperipheral cards
BACnet
Graphics
14
15
Dynamix Tools is fire system software designed for users. It is easy to operate, easy to understand and makes the complicated simple.
Dynamix Tools comprises a range of specific tools allowing users to achieve what they want quickly and easily, not get bogged down in large, clumsy and complicated software.
Dynamix Tools is being continually developed for the MxPro 5 panel range, adding new features and performance enhancements. Recently these have included comprehensive false alarm management and alarm verification features.
Our position in the global fire industry means we help guide legislation and can implement software changes quickly, keeping our customer systems right up to date. We also listen closely to our customers and often produce features for specific client requirements.
• Full configuration of single panel or network system
• Automatic design check of site configuration
• Assistants menu helps the engineer to easily configure panels
• Import, export information and print configuration reports
Config Tool
• Extract device information and event logs from single or multiple panels
• Device History including last activation, test, enable, disable and date created
• User defined filters allow data to be grouped and searched in many different ways
• View device status, analogue values and drift (contaminated) information
• Network simulation and test feature
• Categorise events and create User defined reports
Service Tool
• Virtual panel display supports remote interrogation
• Direct USB/RS232 or remote Modem/IP connection
• Real time status information and control
• Event log can be downloaded
Terminal Tool
• Allows the installer’s logo to be displayed on the panels graphical LCD display during Normal Operation
• Uploads standard bitmap images
• Tool allows creation of logos
• JPG and GIF images can be imported
• Used to easily add site maps to TouchControl touch screen repeater
• Can use any illustration from a photo to a line drawing, isometric or plan.
• Simply draw hotspots onto drawing to add fire zone
• Export to microSD card to add to TouchControl RCT
Logo Tool Map App
16
TouchControl is Advanced’s innovative new remote control terminal and repeater.
Easily installed, its HD display enhances any architectural environment and takes system control and monitoring to the next level.
Features:• Attractive, low-profile HD display 10” screen enhances prestigious
environments.• Easy Slide-in Installation Two-part slide in assembly for quick
first fix and final install. • Cost Minimising It’s a stand alone unit, you don’t
add cost to the fire panel with a compromised touchscreen.
• Easily Configured Fully active remote control terminal
and network device almost immediately after installation.
• Interactive Maps and Zone Plans Easily added, using any diagram via our
Map App.• ‘At a Glance’ System Status Unique interface allows easy monitoring
and management of zones and devices.• Complete Control Three level access to all the controls
you’d find on an Advanced RCT via an easy to use interface.
• Customisable Screen Choose from the preloaded
background screens or add your own including installer logos. Run reception presentations. Immediately reverts to Fire use when system signal received.
Visit touchcontrol.advancedco.com or contact us now for a demo
Touchscreen. Remote Control Terminal. Active Maps & Zone Plans.
17
AlarmCalm uses fast hardware, powerful software and intelligent loop devices to build a total solution to false alarms that’s powerful and easy to configure.
The AlarmCalm Button is a fully intelligent verification device that is installed on the loop and works with the AlarmCalm software to allow occupants to acknowledge a fire alarm signal locally, if they believe it has been caused by say smoke from toast or shower vapour.
Features:• Complete Case-and-Effect In depth control over alarm verification
and investigation delays to outputs.• Customised Management for any Site Divide your building(s) into Building
Areas, each with quickly applied group or unique false alarm management settings. 200 Building Areas per panel or 40,000 per network.
• Unlimited points No restriction to the number of points
in a Building Area and you can configure by point.
• Global Acknowledgement Panel inputs can be programmed to
manage verification and output delays.• Full Event Log All verification and output delays
recorded in panel event logs.
• Flexible Verification Set verification by Building Area,
day/night, on or off, change verification times, verification by second device of device mode change.
• Multiple Verification Inputs and Outputs Inputs can include optical, heat and
multisensors, callpoints and AlarmCalm Button or other input modules. Outputs can be sounders, beacons and relays etc. Sounder ring styles can be configured.
• Failsafe Operation Total control over verification times.
Users can only extend Verification once. Set max number of areas in Verification before full Fire is signaled.
• Easy Management of Outputs Output delays are handled in exactly
the same way as Verifications, making set up very simple.
Visit alarmcalm.advancedco.com or contact us now for a demo
Complete False Alarm Management.
Red Line False Alarms
Fast Hardware Simple Software Intelligent Loop Devices
18
Advanced360 offers total customer care from a staff of industry experts and engineers.
Support can cover help specifying a system or during installation or maintenance. Advanced360 also delivers full, free-of-charge installer training, online and telephone support and system and fault modeling services. It’s advanced, end-to-end fire system support, free to all customers.
New Lifetime Support PortalsAdvanced360 now offers our customers personalised support for their whole Advanced careers, via online portals. Services include:
• Technical Support Open and view support tickets and see full support history.
• Training View and book training slots. Download your certificates at any time.
• Software Download software and save software packages by installation/site.
• Literature Manuals, specifications and technical information etc all available for download.
• Product Demos Book a demo and request brochures, literature and technical information.
• Approved Partner Certificates Available for order and download.
• Warranty Certificates Download warranty certs for your sites. Include your company details for end users. Request marketing and PR support for interesting sites.
Sign up now at 360.advancedco.com
Our Legendary Customer Support. In Person and Online.
19
Advanced’s special engineering team develops unique interfaces and panel solutions to specific customer requirements.
Solutions can include mimic panels, special enclosures, environmental protection, high specification control units, third party system monitors, interfaces and control units and 8+ loop panels in a variety of enclosures.
The AdSpecials team can manage the whole process from specification and design to manufacture and delivery and will project manage the process so deadlines are maintained.
The Best Custom Build in the Industry.
Contact us now to discuss your requirements
20
The quality, performance and ease-of-use of Advanced’s fire systems means we are a supplier of choice to fire and facilities professionals globally.
Our systems hold global approvals and can scale from single panel, single loop to huge, multi-loop, high-speed networks covering vast areas.
We are specified and installed in some of the most prestigious and challenging locations in over 60 countries worldwide.
Visit www.advancedco.com for more info.
Project Leadership
21
MxPro Parts listProduct Code Description
MxPro 5 Fire Control Panels MxPro 5 Fire Control panels (Apollo/Hochiki Protocol)
MxPro 5 - 1 Loop Panels
MX-5101 1 Loop fire panel in small enc.
MX-5101M 1 Loop fire panel in medium enc.
MX-5101L 1 Loop fire panel in large enc.
MX-5101D 1 Loop fire panel in large-deep enc.
MX-5101R 1 Loop 19" rack mount FACP
MxPro 5 - 2 Loop Panels
MX-5201 1-2 Loop fire panel c/w 1 loop card in medium enc.
MX-5201L 1-2 Loop fire panel c/w 1 loop card in large enc.
MX-5201D 1-2 Loop fire panel c/w 1 loop card in large-deep enc.
MX-5201R 1-2 Loop 19" rack mount FACP c/w 1 loop card
MX-5202 1-2 Loop fire panel c/w 2 loop cards in medium enc.
MX-5202L 1-2 Loop fire panel c/w 2 loop cards in large enc.
MX-5202D 1-2 Loop fire panel c/w 2 loop cards in large-deep enc.
MX-5202R 1-2 Loop 19" rack mount FACP c/w 2 loop cards
MxPro 5 - 4 Loop Panels
MX-5401 1-4 Loop fire panel c/w 1 loop card in large enc.
MX-5401D 1-4 Loop fire panel c/w 1 loop card in deep enc.
MX-5401R 1-4 Loop 19" rack mount FACP c/w 1 loop card
MX-5401E 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5402 1-4 Loop fire panel c/w 2 loop cards in large enc.
MX-5402D 1-4 Loop fire panel c/w 2 loop cards in deep enc.
MX-5402R 1-4 Loop 19" rack mount FACP c/w 2 loop cards
MX-5402E 1-4 Loop fire panel c/w 2 loop cards in extended enc.
MX-5403 1-4 Loop fire panel c/w 3 loop cards in large enc.
MX-5403D 1-4 Loop fire panel c/w 3 loop cards in deep enc.
MX-5403R 1-4 Loop 19" rack mount FACP c/w 3 loop card
MX-5403E 1-4 Loop fire panel c/w 3 loop cards in extended enc.
MX-5404 1-4 Loop fire panel c/w 4 loop cards in large enc.
MX-5404D 1-4 Loop fire panel c/w 4 loop cards in deep enc.
MX-5404R 1-4 Loop 19" rack mount FACP c/w 4 loop card
MX-5404E 1-4 Loop fire panel c/w 4 loop cards in extended enc.
MxPro 5 - 8 Loop Panels
MX-5802 2-8 Loop fire panel c/w 2 loop cards. Standard network
MX-5803 2-8 Loop fire panel c/w 3 loop cards. Standard network
MX-5804 2-8 Loop fire panel c/w 4 loop cards. Standard network
MX-5805 2-8 Loop fire panel c/w 5 loop cards. Standard network
MX-5806 2-8 Loop fire panel c/w 6 loop cards. Standard network
MX-5807 2-8 Loop fire panel c/w 7 loop cards. Standard network
MX-5808 2-8 Loop fire panel c/w 8 loop cards. Standard network
MX-5802/FT 2-8 Loop fire panel c/w 2 loop cards. Fault-tolerant network
MX-5803/FT 2-8 Loop fire panel c/w 3 loop cards. Fault-tolerant network
MX-5804/FT 2-8 Loop fire panel c/w 4 loop cards. Fault-tolerant network
MX-5805/FT 2-8 Loop fire panel c/w 5 loop cards. Fault-tolerant network
MX-5806/FT 2-8 Loop fire panel c/w 6 loop cards. Fault-tolerant network
MX-5807/FT 2-8 Loop fire panel c/w 7 loop cards. Fault-tolerant network
MX-5808/FT 2-8 Loop fire panel c/w 8 loop cards. Fault-tolerant network
MxPro 5 Series Fire Control panels (AV Protocol)
MxPro 5 - 1 Loop V Series Panels
MX-5101V 1 Loop fire panel in small enc.
MX-5101VM 1 Loop fire panel in medium enc.
MX-5101VL 1 Loop fire panel in large enc.
MX-5101VD 1 Loop fire panel in large-deep enc.
MX-5101VR 1 Loop 19" rack mount FACP
Product Code Description
MxPro 5 - 2 Loop V Series Panels
MX-5201V 1-2 Loop fire panel c/w 1 loop card in medium enc.
MX-5201VL 1-2 Loop fire panel c/w 1 loop card in large enc.
MX-5201VD 1-2 Loop fire panel c/w 1 loop card in large-deep enc.
MX-5201VR 1-2 Loop 19" rack mount FACP c/w 1 loop card
MX-5202V 1-2 Loop fire panel c/w 2 loop cards in medium enc.
MX-5202VL 1-2 Loop fire panel c/w 2 loop cards in large enc.
MX-5202VD 1-2 Loop fire panel c/w 2 loop cards in large-deep enc.
MX-5202VR 1-2 Loop 19" rack mount FACP c/w 2 loop cards
MxPro 5 - 4 Loop V Series Panels
MX-5401V 1-4 Loop fire panel c/w 1 loop card in large enc.
MX-5401VD 1-4 Loop fire panel c/w 1 loop card in deep enc.
MX-5401VR 1-4 Loop 19" rack mount FACP c/w 1 loop card
MX-5401VE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5402V 1-4 Loop fire panel c/w 2 loop cards in large enc.
MX-5402VD 1-4 Loop fire panel c/w 2 loop card in deep enc
MX-5402VR 1-4 Loop 19" rack mount FACP c/w 2 loop cards
MX-5402VE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5403V 1-4 Loop fire panel c/w 3 loop cards in large enc.
MX-5403VD 1-4 Loop fire panel c/w 3 loop card in deep enc
MX-5403VR 1-4 Loop 19" rack mount FACP c/w 3 loop card
MX-5403VE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5404V 1-4 Loop fire panel c/w 4 loop card in large enc.
MX-5404VD 1-4 Loop fire panel c/w 4 loop card in deep enc
MX-5404VR 1-4 Loop 19" rack mount FACP c/w 4 loop card
MX-5404VE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MxPro5 - 8 Loop V Series Panels
MX-5802V 2-8 Loop fire panel c/w 2 loop cards. Standard network
MX-5803V 2-8 Loop fire panel c/w 3 loop cards. Standard network
MX-5804V 2-8 Loop fire panel c/w 4 loop cards. Standard network
MX-5805V 2-8 Loop fire panel c/w 5 loop cards. Standard network
MX-5806V 2-8 Loop fire panel c/w 6 loop cards. Standard network
MX-5807V 2-8 Loop fire panel c/w 7 loop cards. Standard network
MX-5808V 2-8 Loop fire panel c/w 8 loop cards. Standard network
MX-5802V/FT 2-8 Loop fire panel c/w 2 loop cards. Fault tolerant network
MX-5803V/FT 2-8 Loop fire panel c/w 3 loop cards. Fault tolerant network
MX-5804V/FT 2-8 Loop fire panel c/w 4 loop cards. Fault tolerant network
MX-5805V/FT 2-8 Loop fire panel c/w 5 loop cards. Fault tolerant network
MX-5806V/FT 2-8 Loop fire panel c/w 6 loop cards. Fault tolerant network
MX-5807V/FT 2-8 Loop fire panel c/w 7 loop cards. Fault tolerant network
MX-5808V/FT 2-8 Loop fire panel c/w 8 loop cards. Fault tolerant network
MxPro 5 Series Fire Control panels (Nittan Evolution Protocol)
MxPro 5 - 1 Loop N Series Panels
MX-5101N 1 Loop fire panel in small enc.
MX-5101NM 1 Loop fire panel in medium enc.
MX-5101NL 1 Loop fire panel in large enc.
MX-5101ND 1 Loop fire panel in large-deep enc.
MX-5101NR 1 Loop 19" rack mount FACP
MX-5200N Series panels
MX-5201N 1-2 Loop fire panel c/w 1 loop card
MX-5201NL 1-2 Loop fire panel c/w 1 loop card in large enc.
MX-5201ND 1-2 Loop fire panel c/w 1 loop card in large-deep enc.
MX-5201NR 1-2 Loop 19" rack mount FACP c/w 1 loop card
MX-5202N 1-2 Loop fire panel c/w 2 loop cards
MX-5202NL 1-2 Loop fire panel c/w 2 loop cards in large enc.
MX-5202ND 1-2 Loop fire panel c/w 2 loop cards in large-deep enc.
MX-5202NR 1-2 Loop 19" rack mount FACP c/w 2 loop cards
MxPro Parts list
22
Product Code Description
MX-5400N Series panels
MX-5401N 1-4 Loop fire panel c/w 1 loop card in large enc.
MX-5401ND 1-4 Loop fire panel c/w 1 loop card in deep enc.
MX-5401NR 1-4 Loop 19" rack mount FACP c/w 1 loop card
MX-5401NE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5402N 1-4 Loop fire panel c/w 2 loop cards in large enc.
MX-5402ND 1-4 Loop fire panel c/w 2 loop card in deep enc.
MX-5402NR 1-4 Loop 19" rack mount FACP c/w 2 loop cards
MX-5402NE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5403N 1-4 Loop fire panel c/w 3 loop cards in large enc.
MX-5403ND 1-4 Loop fire panel c/w 3 loop card in deep enc.
MX-5403NR 1-4 Loop 19" rack mount FACP c/w 3 loop card
MX-5403NE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5404N 1-4 Loop fire panel c/w 4 loop card in large enc.
MX-5404ND 1-4 Loop fire panel c/w 4 loop card in deep enc.
MX-5404NR 1-4 Loop 19" rack mount FACP c/w 4 loop card
MX-5404NE 1-4 Loop fire panel c/w 1 loop card in extended enc.
MX-5800N Series panels
MX-5802N 2-8 Loop fire panel c/w 2 loop cards. Standard network
MX-5803N 2-8 Loop fire panel c/w 3 loop cards. Standard network
MX-5804N 2-8 Loop fire panel c/w 4 loop cards. Standard network
MX-5805N 2-8 Loop fire panel c/w 5 loop cards. Standard network
MX-5806N 2-8 Loop fire panel c/w 6 loop cards. Standard network
MX-5807N 2-8 Loop fire panel c/w 7 loop cards. Standard network
MX-5808N 2-8 Loop fire panel c/w 8 loop cards. Standard network
MX-5802N/FT 2-8 Loop fire panel c/w 2 loop cards. Fault tolerant network
MX-5803N/FT 2-8 Loop fire panel c/w 3 loop cards. Fault tolerant network
MX-5804N/FT 2-8 Loop fire panel c/w 4 loop cards. Fault tolerant network
MX-5805N/FT 2-8 Loop fire panel c/w 5 loop cards. Fault tolerant network
MX-5806N/FT 2-8 Loop fire panel c/w 6 loop cards. Fault tolerant network
MX-5807N/FT 2-8 Loop fire panel c/w 7 loop cards. Fault tolerant network
MX-5808N/FT 2-8 Loop fire panel c/w 8 loop cards. Fault tolerant network
MxPro 5 Remote Terminals
MX-5010 Remote display terminal (RDT). Standard network
MX-5010/FT Remote display terminal (RDT). Fault tolerant
MX-5020 Remote control terminal (RCT) small. Standard network
MX-5020/FT Remote control terminal (RCT) small. Fault tolerant
MX-5030 Remote control terminal (RCT) large. Standard network
MX-5030/FT Remote control terminal (RCT) large. Fault tolerant
Touch Control
TOUCH-10 Touch-screen terminal (standard network)
TOUCH-10/FT Touch-screen terminal (fault-tolerant network)
TOUCH-10-SBB Touch-screen terminal - surface back box
Peripheral Expansion Network Node NEW
MXP-545 PENN - (standard network)
MXP-545/FT PENN - (fault-tolerant network)
Product Code Description
MxPro 5 Peripherals
Note; Additional Peripherals listed under MxPro4 / MxPro 5 Universal Peripherals
MXP-501 Remote battery temperature sensor
MXP-502 Loop driver card - Apollo, Hochiki, Argus, Vega
MXP-567 Loop driver card - Nittan
MXP-503 * Network card - standard
MXP-505 Sounder (pt13) active EOL
MXP-506 Routing termination card
MXP-507 * 2-way relay card
MXP-509 * Network card - fault tolerant
MXP-512 * Printer assembly
MXS-509 Spare paper roll for Mxp-512 printer
MXP-532 * Routing / protection interface
MXP-536 * P-BUS 8-way conventional zone card
MXP-537 * P-BUS 10-way switch input card
MXP-538 P-BUS 16-way switch (form factor) module 16 switches, 3 integrated, programmable LED's per switch (red, yellow, green)
MXP-539 P-BUS MIMIC driver card (16 input + 48 output) 16 switch inputs and 48 LED driver outputs. Supports up to 5 Mxp-052 10 relay output modules
MXP-547 * ESPA pager interface
* Add F - for fitted
MxPro5 AlarmCalm
MXP-541A-002 AlarmCalm button w buzzer (Apollo)
MXP-541V-002 AlarmCalm button w buzzer (Argus)
MxPro 5 LED Indication
MXP-513M-050RD * 50 Zone fire (red) - medium enc
MXP-513M-050RY * 25 Zone fire (red) + fault (yel) - medium enc.
MXP-513M-050YL * 50 Zone fault (yel) - medium enc.
MXP-513L-050RD * 50 Zone fire (red) - large enc
MXP-513L-050RY * 25 Zone fire (red) + fault (yel) - large enc.
MXP-513L-050YL * 50 Zone fault (yel) - large enc.
MXP-513L-100RD * 100 Zone fire (red) - large enc.
MXP-513L-100RY * 50 Zone fire (red) + fault (yel) - large enc.
MXP-513L-100YL * 100 Zone fault (yel) - large enc.
MXP-513L-200RY * 200 Zone - large enc (red/yel)
MXP-513L-050CRY * 50 Zone column format - large enc (red/yel)
MXP-513L-050CRYG * 50 Zone column format - large enc. (30 x red/yel - 20 grn/yel)
MXP-513-050RD * 50 Zone fire (red) - extended enc.
MXP-513-050RY * 25 Zone fire (red) + fault (y) - extended enc.
MXP-513-050YL * 50 Zone fault (yel) - extended enc.
MXP-513-100RD * 100 Zone fire (red) - extended enc.
MXP-513-100RY * 50 Zone fire (red) + fault (y) - extended enc.
MXP-513-100YL * 100 Zone fault (yel) - extended enc.
MXP-513-200RY * 200 Zone - extended enc. (red/yel)
MXP-513-050CRY * 50 Zone column format - extended enc. (red/yel)
MXP-513-050CRYG * 50 Zone column format - extended enc. (30 x red/yel - 20 grn/yel)
* Add F - for fitted
MxPro5 Modems
MXP-528 Modem card (24V)
MXP-528F Modem card (24V) - fitted*
MXP-028-BX Modem card (24V) - boxed
* Can be fitted to a medium, large or extended enclosure only
23
Product Code Description
MxPro 5 Key Switches
MXP-511 Access enable key switch
MXP-511F Access enable key switch - fitted
MXP-516 2-POS key switch (trapped)
MXP-516F 2-POS key switch (trapped) - fitted
MXP-517 2-POS key switch (untrapped)
MXP-517F 2-POS key switch (untrapped) - fitted
MXP-515 3-POS key switch (trapped)
MXP-515F 3-POS key switch (trapped) - fitted
MXP-518-001 Access enable key switch for 5010/5020
MXP-518-001F Access enable key switch for 5010/5020 - fitted
MXP-518-002 Access enable key switch for 5030
MXP-518-002F Access enable key switch for 5030 - fitted
MXP-519 2-POS key switch (Mom - trapped)
MXP-519F 2-POS key switch (Mom - trapped) - fitted
MxPro 5 Spares
MXS-501 * Spare single loop base card c/w PSU (no loop cards) *Add V for AV protocol, N for Evolution
MXS-502 * Spare two loop base card c/w PSU (no loop cards) *Add V for AV protocol
MXS-503 * Spare four loop base card c/w PSU (no loop cards) *Add V for AV protocol
MXS-504 Spare display card
MXS-506 Spare MX-5010 card only
MXS-506/FT Spare MX-5010 card only - fault-tolerant
MXS-507 Spare MX-5020 card only
MXS-507/FT Spare MX-5020 card only - fault-tolerant
MXS-508 Spare MX-5030 card only
MXS-508/FT Spare MX-5030 card only - fault-tolerant
MXS-511 Spare access enable key switch (Lorlin style)
MXS-516 Spare 2-position key switch - trapped (Lorlin style)
MXS-517 Spare 2-position key switch - un-trapped (Lorlin style)
MXS-511-KEY Spare Mxp-511 access enable key
MXS-518 MX-5000 spare kits
MXS-519 MX-5000 rack mount spare kit
MXS-520 MX-5000 remote terminal spares kit
MXS-521 MX-5000 battery leads
MXS-522 MX-5000 rack mount battery leads
MXS-5-FP-S Spare fascia plate and membrane - small
MXS-5-FP-ML Spare fascia plate and membrane - medium / large
MxPro 5 Flushing Bezels
MXM-501 Semi-flushing bezel - small enc.
MXM-502 Semi-flushing bezel - medium enc.
MXM-503 Semi-flushing bezel - large enc.
MXM-509 Semi-flushing bezel - MX-5030 RCT - large
MXM-521 Semi-flushing bezel - MX-5010 / 5020
MXM-536 Semi-flushing bezel - extended enc.
MxPro 5 Plexi glass (Lexan) Door - Retro-fit
MXM-507 Glazed door kit - large enclosure
MXM-507Z Glazed door kit (double aperture) - large enc.
MXM-508 Glazed door kit - medium enclosure
MXM-508Z Glazed door kit (double aperture) - medium enc.
MXS-505 Spare key - MxPro 5 glazed door
MXM-538-D1 Glazed door kit with zone aperture - extended enc.
MXM-538-D2 Glazed door kit with 2 x glazed apertures - extended enc.
MXM-538-D3 Glazed door kit with mimic aperture - extended enc.
Product Code Description
MxPro 5 Enclosures
MXM-504 Medium termination enc.
MXM-505 Large termination enc.
MXM-506 Large-deep termination enc.
MXM-516 Medium battery (18ah) / utility enc.
MXM-517 Large battery (18ah) / utility enc.
MXM-518 Deep utility enc.
MXM-519 Chassis mounting plate for utility enc. (3 cards)
MXM-546 MX-5000 deep battery (45ah) enc.
MXM-522-BB Small enc. - spare back box
MXM-522-D1 Small enc. - spare door
MXM-523-BB Medium enc. - spare back box
MXM-523-D1 Medium enc. - spare door
MXM-523-D2 Medium enc. - spare door (c/w zone aperture)
MXM-524-BB Large enc. - spare back box
MXM-524-D1 Large/deep enc. - spare door
MXM-524-D2 Large/deep enc. - spare door (c/w zone aperture)
MXM-524-D3 Large/deep enc. - spare door (c/w 2 x switch apertures)
MXM-524-D4 Large/deep enc. - mimic door with single aperture
MXM-524-D5 Large/deep enc. - blank door
MXM-525-BB Deep enclosure - spare back box
MXM-530 Cable clamp
MXM-531 Medium document enc.
MXM-532 Large document enc.
MXM-533 Modem/ESPA/BMS interface enc.
MXM-537-BB Extended enc. - back box
MXM-537-BP Extended enc. - Blank plate for zone LED aperture
MXM-537-D1 Extended enc. - spare door
MXM-537-D2 Extended enc. - spare panel door with mimic aperture
MXM-543-BB Mx-5010/5020 - spare back box
MXM-544-BB Mx-5030 - spare back box
MXM-543-D1 Mx-5010/5020 - spare panel cover
MXM-543-D2 Mx-5010/5020 - spare panel cover + k/s app
MXM-544-D1 Mx-5030 - spare panel cover
MXM-543-D2 Mx-5030 - spare panel cover + k/s app
MxPro 5 Special Finishes
MXM-501-SSB Semi-flushing bezel - small enc. stainless steel brushed
MXM-501-SSM Semi-flushing bezel - small enc. stainless steel mirrored
MXM-502-SSB Semi-flushing bezel - medium enc. stainless steel brushed
MXM-502-SSM Semi-flushing bezel - medium enc. stainless steel mirrored
MXM-503-SSB Semi-flushing bezel - large enc. stainless steel brushed
MXM-503-SSM Semi-flushing bezel - large enc. stainless steel mirrored
MXM-509-SSB Semi-flushing bezel - RCT large. Stainless steel brushed
MXM-509-SSM Semi-flushing bezel - RCT large stainless steel mirrored
MXM-521-SSB Semi-flushing bezel - MX-5010 / 5020 stainless steel brushed
MXM-521-SSM Semi-flushing bezel - MX-5010 / 5020 stainless steel mirrored
MXM-522-D1-SSB * Small enc. - spare door. Stainless steel brushed
MXM-522-D1-SSM Small enc. - spare door. Stainless steel mirrored
MXM-523-D1-SSB * Medium enc. - spare door. Stainless steel brushed
MXM-523-D1-SSM Medium enc. - spare door. Stainless steel mirrored
MXM-523-D2-SSB * Medium enc. - spare door (c/w zone aperture). Stainless steel brushed
MXM-523-D2-SSM Medium enc. - spare door (c/w zone aperture). Stainless steel mirrored
MXM-524-D1-SSB * Large/deep enc. - spare door. Stainless steel brushed
MXM-524-D1-SSM Large/deep enc. - spare door. Stainless steel mirrored
MXM-524-D2-SSB * Large/deep enc. - spare door (c/w zone aperture). Stainless steel brushed
24
MxPro Parts listProduct Code Description
MXM-524-D2-SSM Large/deep enc. - spare door (c/w zone aperture). Stainless steel mirrored
MXM-543-D1-SSB MX-5010/5020 - panel cover. Stainless steel brushed
MXM-543-D1-SSM MX-5010/5020 - panel cover. Mirror polished
MXM-543-D2-SSB MX-5010/5020 - panel cover + KS Ap. Stainless steel brushed.
MXM-543-D2-SSM MX-5010/5020 - panel cover + KS Ap. Mirror polished
MXM-544-D1-SSB MX-5030 RCT - panel cover. Stainless steel brushed.
MXM-544-D1-SSM MX-5030 RCT - panel cover. Mirror polished
MXM-544-D2-SSB MX-5030 RCT - panel cover + KS Ap. Stainless steel brushed
MXM-544-D2-SSM MX-5030 RCT - panel cover + KS Ap. Mirror polished
MXM-524-BB-SSB
Spare large back box for use w/SS door (MW334E)
MXM-523-BB-SSB
Spare medium back box for use w/SS door (MW334E)
MXM-522-BB-SSB
Spare small back box for use w/SS door (MW334E)
MXM-525-BB-SSB
Spare deep back box for use w/SS door (MW334E)
* Add F - fitted (includes Silver back box & hinge strip)
MxPro 5 Rack Mount Enclosure
MXM-510-16U IP55 19" Rack mount enclosure - 16U high
MXM-510-20U IP55 19" Rack mount enclosure - 20U high
MXM-510-KL CAM key-lock kit for outer door
MXM-510-BS 19" Rack mount - battery shelf
MXM-510-BS1 19" Rack mount - battery shelf lower
MXM-510-CP 19" Rack mount - chassis plate
MXP-513R-050RD
19" Rack mount 4U LED card - 50 zone fire (red)
MXP-513R-050RY 19" Rack mount 4U LED card - 50 zone fire/flt (r/y)
MXP-513R-050YL 19" Rack mount 4U LED card - 50 zone flt (yel)
MXP-513R-100RD
19" Rack mount 4U LED card - 100 zone fire (red)
MXP-513R-100RY 19" Rack mount 4U LED card - 100 zone fire/flt (r/y)
MXP-513R-100YL 19" Rack mount 4U LED card - 100 zone fault (yellow)
MXP-513R-200RY 19" Rack mount 4U programmable LED card - 200 zone (red/yel)
MXP-513R-050CRY
19" Rack mount 4U programmable LED card - 50 zone column format (red/yel)
MXP-513R-050CRYG
19" Rack mount 4U programmable LED card 50 zone column format (30 x red/yel - 20 x grn/yel)
MXP-514 MxPro 5 rack AC filter card
MXM-511-1U 19" Rack mount blanking plate - 1U
MXM-511-2U 19" Rack mount blanking plate - 2U
MXM-511-3U 19" Rack mount blanking plate - 3U
MXM-511-4U 19" Rack mount blanking plate - 4U
MXM-511-6U 19" Rack mount blanking plate - 6U
MXM-511-1U-TOP 19" Rack mount blanking plate - 1U-TOP
MXM-512 19" Rack mount blanking LED plate - 4U
MXM-513-BB 19" Rack mount back box - 6U
MXM-513-BP 19" Rack mount switch / LED blank plate - 6U
MXM-513-D1 19" Rack mount door D1 blank - 6U
MXM-513-D2 19" Rack mount door D2 LED - 6U
MXM-513-D3 19" Rack mount door D1 c/w aperture - 6U
MXM-513-FP 19" Rack mount fascia plate blank - 6U
MXM-513-MF 19" Rack mount switch / LED mounting frame - 6U
MXM-514-BB 19" Rack mount back box - 8U
MXM-514-D1 19" Rack mount door D1 c/w aperture - 8U
MXM-514-FP 19" Rack mount fascia plate blank - 8U
Product Code Description
MXM-515-6U 19" Rack mount chassis plate - 6U
MXM-515-8U 19" Rack mount chassis plate - 8U
MXM-535-D1 19" Rack mount 13U hinged door (accepts 9 x MXP-538 switch cards or blank plates)
MxPro 4 / MxPro 5 Universal PeripheralsNetwork Boosters and Convertors
MXP-030 Standard network booster/isolator (DIN-rail module)
MXP-631-MM Ad-Net / fibre optic converter multi-mode
MXP-631-SM Ad-Net / fibre optic converter single-mode
MXP-542 24VDC - 24VDC convertor / isolator (for use with Mxp-631 Fibre network convertors and MxPro 5)
Mimic Driver Cards, Indicators & Network I/O Controllers
MXP-020-100 100 way remote LED mimic driver (un-boxed)
MXP-020-100/FT Fault tolerant 100-way remote LED mimic driver (un-boxed)
MXP-045 50-way network I/O controller (un-boxed)
MXP-045/FT 50 way fault-tolerant network I/O controller (un-boxed)
MXS-026 High intensity red LED & 600mm lead for Mxp-020 / 027 & 045
MXS-026-YEL High intensity yellow LED & 600mm lead for Mxp-020 / 027 & 045
MXS-026-GRN High intensity green LED & 600mm lead for Mxp-020 / 027 & 045
MXP-052 Mimic driven 10-way relay output card
MXP-052-DIN Mimic driven 10-way relay output card in din-rail carrier
MXS-031-2T 2-Position key switch trapped for Mxp-045
MXS-031-2U 2-Position key switch un-trapped for Mxp-045
MXS-031-3U 3-Position key switch un-trapped for Mxp-045
P-Bus Expansion Cards
MXP-034 (F)* Peripheral bus - 4-way sounder card
MXP-034-BXP Peripheral bus - 4-way sounder card with 4A PSU (boxed)
MXP-035(F)* Peripheral bus - 4-way relay card
MXP-035-BXP Peripheral bus - 4-way relay card with 1.5A PSU (boxed)
* Add F - for fitted (except Mx-4100, Mx-5100)
EN54-4 'Approved' Power Supply Units
MXP-549 1.5A EN54-4 PSE & battery charger
MXP-550 3A EN54-4 PSE & battery charger
MXP-550/D 3A EN54-4 PSE & battery charger. Deep enc.
MXP-551 5A EN54-4 PSE & battery charger
MXP-551/D 5A EN54-4 PSE & battery charger. Deep enc.
MXP-049 1.5A EN54-4 PSU & charger (boxed - 7Ah battery capacity)
MXP-050-001 3A EN54-4 PSU & charger (boxed - 7Ah battery capacity)
MXP-050-002 3A EN54-4 PSU & charger (boxed - 17Ah battery capacity)
MXP-051 5A EN54-4 PSU & charger (boxed - 17Ah battery capacity)
MXP-051/D 5A EN54-4 PSU & charger (boxed - 38Ah battery capacity)
MxPro Input and Output Cards
MXP-046 Damper interface module (Apollo protocol)
MXP-046-BX1 Damper interface module - boxed (Apollo protocol)
MXP-053 2-way input stretch / latch module
MxPro Interfaces
MXP-510-BX BMS / Graphics I/F (boxed)
MXP-510-BX/FT BMS / Graphics I/F (boxed) fault tolerant
MXP-510 BMS / Graphics I/F (card only)
MXP-510/FT BMS / Graphics I/F (card only) fault tolerant
MXP-547-BX ESPA Pager interface (boxed)
MXP-554-BX IP Gateway (boxed)
25
Product Code Description
MXP-554-BX/FT IP Gateway (boxed) fault tolerant
MXP-554 IP Gateway (card only)
MXP-554/FT IP Gateway (card only) fault tolerant
MXP-642 Commander- BACnet / Modbus (IP) interface (standard/basic) **
MXP-642C Commander- BACnet / Modbus (IP) interface (configured) **
23-PSU/250 Power supply for commander 12VDC 2.5A
* Add F - fitted (except Mx-4100, Mx-5100). ** Requires Mxp-510 BMS Interface
Dynamix Tools PC Software
See "Cables & Connectors" section for spare and USB compatible upload / download leads
PC-NET-003 MxPro configuration software & lead
PC-NET-003-USB MxPro configuration software & USB upload/download lead
PC-NET-004 MxPro remote dial-up software (virtual panel)
PC-NET-005-L1 Graphical control software* standard version up to 3 panels
PC-NET-005-L2 Graphical control software* standard version up to 15 panels
PC-NET-005-L2p Graphical control software* premium version up to 15 panels
PC-NET-005-L3 Graphical control software* standard version up to 200 panels
PC-NET--005-L3p Graphical control software* premium version up to 200 panels
PC-NET-005-SWM
Smart watch module
PC-NET-005-SWM6
Smart watch module (4-6 panel)
PC-NET-005-SWM15
Smart watch module (7-15 panel)
PC-NET-005-SWM4R
Smart watch module - 4 inputs
PC-NET-005-SCU Smart cube unit
PC-NET-05-L1R-L2R
Dongle upgrade L1R - L2R
PC-NET-05-L2R-L3R
Dongle upgrade L2R to L3R
PC-NET-05-L2R-L2P
Dongle upgrade L2R to L2P
PC-NET-05-L2P-L3P
Dongle upgrade L2P to L3P
PC-NET-05-L3R-L3P
Dongle upgrade L3R to L3P
PC-NET-007 MxPro logo programming software
PC-NET-015 MxPro service tool software
* requires Mxp-510 BMS interface
Cables & Connectors (Upload/Download Leads)
UP-001 RS232 9-way to 3-way plug in connector (MX upload/download lead)
UP-006 USB upload /download lead for MX config software
MxPro 4 Fire Control Panels (Apollo/Hochiki Protocol)
MxPro 4 - 1 Loop panels
MX-4100 1 Loop fire panel (no loop driver required)
MX-4100/L 1 Loop fire panel with lockable hinged door
MX-4100/LG 1 Loop fire panel c/w lockable hinged door & Lexan (perspex) kit
MxPro 4 - 2 Loop panels
MX-4200 1-2 Loop fire panel (no loop cards)
MX-4200/D 1-2 Loop fire panel in deep enclosure suitable for up to 2 x 38Ah batteries
MX-4200/R 1-2 Loop fire panel with 19" mounting bezel (no loop cards)
MX-4200/LE 1-2 Loop fire panel in large enclosure (950 mm high)
MX-4201 1-2 Loop fire panel c/w 1 loop card
MX-4202 1-2 Loop fire panel c/w 2 loop cards
MX-4201/D 1-2 Loop fire panel c/w 1 loop card in deep enc.
MX-4202/D 1-2 Loop fire panel c/w 2 loop cards in deep enc.
Product Code Description
MxPro 4 - 4 Loop panelsMX-4400 1-4 Loop fire panel (no loop cards)MX-4400/D 1-4 Loop fire panel in deep back box for up to 2 x 38Ah batteriesMX-4400/R 1-4 Loop fire panel with 19" mounting bezel (no loop cards)MX-4400/LE 1-4 Loop fire panel in large enclosure (950 mm high) MX-4401 1-4 Loop fire panel c/w 1 loop cardMX-4402 1-4 Loop fire panel c/w 2 loop cardsMX-4403 1-4 Loop fire panel c/w 3 loop cardsMX-4404 1-4 Loop fire panel c/w 4 loop cardsMX-4401/D 1-4 Loop fire panel c/w 1 loop card in deep enc.MX-4402/D 1-4 Loop fire panel c/w 2 loop cards in deep enc.MX-4403/D 1-4 Loop fire panel c/w 3 loop cards in deep enc.MX-4404/D 1-4 Loop fire panel c/w 4 loop cards in deep enc.
MxPro 4 - 8 Loop panelsMX-4800 2-8 Loop fire panel with standard network card (no loop cards)MX-4802 2-8 Loop fire panel c/w standard network card & 2 loop cardsMX-4803 2-8 Loop fire panel c/w standard network card & 3 loop cardsMX-4804 2-8 Loop fire panel c/w standard network card & 4 loop cardsMX-4805 2-8 Loop fire panel c/w standard network card & 5 loop cardsMX-4806 2-8 Loop fire panel c/w standard network card & 6 loop cardsMX-4807 2-8 Loop fire panel c/w standard network card & 7 loop cardsMX-4808 2-8 Loop fire panel c/w standard network card & 8 loop cardsMX-4800/FT 2-8 Loop fire panel with fault-tolerant network card (no loop cards)MX-4802/FT 2-8 Loop fire panel c/w fault-tolerant network card & 2 loop cardsMX-4803/FT 2-8 Loop fire panel c/w fault-tolerant network card & 3 loop cardsMX-4804/FT 2-8 Loop fire panel c/w fault-tolerant network card & 4 loop cardsMX-4805/FT 2-8 Loop fire panel c/w fault-tolerant network card & 5 loop cardsMX-4806/FT 2-8 Loop fire panel c/w fault-tolerant network card & 6 loop cardsMX-4807/FT 2-8 Loop fire panel c/w fault-tolerant network card & 7 loop cardsMX-4808/FT 2-8 Loop fire panel c/w fault-tolerant network card & 8 loop cards
MxPro 4 Series Fire Control Panels (AV or Nittan Evolution Protocol)
For Nittan Evolution protocol, replace V with NMxPro 4 - 2 Loop V and N Series panels
MX-4201V 1-2 Loop fire panel c/w 1 loop cardMX-4202V 1-2 Loop fire panel c/w 2 loop cardsMX-4201V/D 1-2 Loop fire panel c/w 1 loop card in deep enc.MX-4202V/D 1-2 Loop fire panel c/w 2 loop cards in deep enc.MX-4201V/R 1-2 Loop fire panel c/w 1 loop card with 19" mounting bezelMX-4202V/R 1-2 Loop fire panel c/w 2 loop cards with 19" mounting bezelMX-4201V/LE 1-2 Loop fire panel c/w 1 loop card in large enc.MX-4202V/LE 1-2 Loop fire panel c/w 2 loop cards in large enc.
MxPro 4 - 4 Loop V and N Series panelsMX-4401V 1-4 Loop fire panel c/w 1 loop cardMX-4402V 1-4 Loop fire panel c/w 2 loop cardsMX-4403V 1-4 Loop fire panel c/w 3 loop cardsMX-4404V 1-4 Loop fire panel c/w 4 loop cardsMX-4401V/D 1-4 Loop fire panel c/w 1 loop card in deep enc.MX-4402V/D 1-4 Loop fire panel c/w 2 loop cards in deep enc.MX-4403V/D 1-4 Loop fire panel c/w 3 loop cards in deep enc.MX-4404V/D 1-4 Loop fire panel c/w 4 loop cards in deep enc.MX-4401V/R 1-4 Loop fire panel c/w 1 loop card with 19" mounting bezelMX-4402V/R 1-4 Loop fire panel c/w 2 loop cards with 19" mounting bezelMX-4403V/R 1-4 Loop fire panel c/w 3 loop cards with 19" mounting bezelMX-4404V/R 1-4 Loop fire panel c/w 4 loop cards with 19" mounting bezelMX-4401V/LE 1-4 Loop fire panel c/w 1 loop card in large enc.MX-4402V/LE 1-4 Loop fire panel c/w 2 loop cards in large enc.MX-4403V/LE 1-4 Loop fire panel c/w 3 loop cards in large enc.MX-4404V/LE 1-4 Loop fire panel c/w 4 loop cards in large enc.
MxPro Parts list
26
Product Code Description
MxPro 4 - 8 loop V and N Series panels
MX-4802V 2-8 Loop fire panel c/w standard network card & 2 loop cards
MX-4803V 2-8 Loop fire panel c/w standard network card & 3 loop cards
MX-4804V 2-8 Loop fire panel c/w standard network card & 4 loop cards
MX-4805V 2-8 Loop fire panel c/w standard network card & 5 loop cards
MX-4806V 2-8 Loop fire panel c/w standard network card & 6 loop cards
MX-4807V 2-8 Loop fire panel c/w standard network card & 7 loop cards
MX-4808V 2-8 Loop fire panel c/w standard network card & 8 loop cards
MX-4802V/FT 2-8 Loop fire panel c/w fault-tolerant network card & 2 loop cards
MX-4803V/FT 2-8 Loop fire panel c/w fault-tolerant network card & 3 loop cards
MX-4804V/FT 2-8 Loop fire panel c/w fault-tolerant network card & 4 loop cards
MX-4805V/FT 2-8 Loop fire panel c/w fault-tolerant network card & 5 loop cards
MX-4806V/FT 2-8 Loop fire panel c/w fault-tolerant network card & 6 loop cards
MX-4807V/FT 2-8 Loop fire panel c/w fault-tolerant network card & 7 loop cards
MX-4808V/FT 2-8 Loop fire panel c/w fault-tolerant network card & 8 loop cards
MxPro 4 Loop Drivers
MXP-002 Loop driver for MX-4400/4200 (Apollo or Hochiki protocol)
MXP-067 Loop driver for MX-4400/4200 (Nittan Evolution protocol)
MXP-069 Loop driver for MX-4400/4200 (AV protocol)
MxPro 4 Series Remote Terminals
MX-4010 Remote display terminal with standard network interface, 24V DC
MX-4020 Remote control terminal with standard network interface, 24V DC
MX-4010/FT Remote display terminal with fault-tolerant network interface, 24V DC
MX-4020/FT Remote control terminal with fault-tolerant network interface, 24V DC
MxPro 4 Network Cards
MXP-003(F)* Standard network card
MXP-009(F)* Fault tolerant network card
* Add F - fitted to a Mx-4100, Mx-4200 or Mx-4400
MxPro 4 Zonal LED Indication
MXP-024(F)* 20 Zone LED card for Mx-4100 - fitted
MXP-025(F)* 20 Zone LED card for Mx-4200/4400/4800 - fitted
MXP-013-050F 50 zone LED card for Mx-4200/4400/4800 - fitted
MXP-013-050 50 zone LED card for Mx-4200 /4400 with door and label (retro-fit)
MXP-013-100F 100 zone LED card for Mx-4200/4400/4800 - fitted
MXP-013-100 100 zone LED card for Mx-4200/4400 with door and label (retro-fit)
MXP-013-200F 200 zone LED card for Mx-4200/4400/4800 - fitted
MXP-013-200 200 zone LED card for Mx-4200/4400 with door and label (retro-fit)
MXP-055F 36 zone slide-in label and LED card for Mx-4200D/ 4400D (requires mimic interface and network card)
* Add F - for fitted
Note; 20 zone card cannot be fitted with an onboard printer.
Product Code Description
MxPro 4 Series PrintersMXP-012F On-board printer for Mx-4200/4400/4800 - fittedMXP-012 On-board printer for Mx-4200/4400/4800 (retro-fit)MXP-012-BX External boxed panel printer for Mx-4100 /4200/4400/4800MXS-014 Spare shrink wrap battery pack for Mxp-012 printerMXS-008 Spare paper roll for Mxp-012 printer (pack of 10)MXP-056 (F)** Mimic/network printer interface card MXP-056(F)**/FT Fault-tolerant mimic/network printer interface card* Add F - for fitted (**to a Mx-4200D or Mx-4400D only) Note: onboard printer cannot be fitted with a 20 zone LED card.
MxPro 4 Input & Output CardsMXP-007(F)* 2-way programmable relay output card for Mx-4100LMXP-008(F)* 8-way programmable relay output card for
Mx-4200/4400/4800MXP-014(F)* 8-way programmable input card for
Mx-4100L/4200/4400/4800MXP-029(F)* Shop Interface Unit (input/output card) for
Mx-4100L/4200/4400/4800* Add F - for fitted
MxPro 4 P-Bus Expansion cardsNote; Additional expansion cards listed under MxPro 4 / MxPro 5 Universal PeripheralsMXP-031(F)* Peripheral Bus interface adaptorMXP-032(F)* Peripheral Bus - fire alarm routing interface card
(monitored output card)* Add F - for fitted to a Mx-4200, Mx-4400 or Mx-4800.
MxPro 4 Modem & Pager InterfaceMXP-028 (F)* Modem card (24V) MXP-028-BX Modem card (24V) boxedMXP-047 (F) * ESPA Pager interface * Add F - for fitted to Mx-4200/4400/4800
MxPro 4 Key SwitchesMXP-011 Access enable key switch assembly MXP-011F Access enable Key switch assembly - fittedMXP-018 Access enable key switch assembly for RDT / RCTMXP-018F Access enable key switch assembly for RDT / RCT - fittedMXP-015* 8-way key switch input card & cable *
(note: accepts up to 8 key switches Mxp-016 / Mxp-017 or 4 x Mxs-015)
MXP-016 2-Position key switch assembly - trappedMXP-016F 2-Position key switch assembly - trapped. fittedMXP-017 2-Position key switch assembly - untrappedMXP-017F 2-Position key switch assembly - untrapped. fittedMXS-015 3-Position key switch assembly c/w 2 flying leadsMXS-015F 3-Position key switch assembly c/w 2 flying leads - fitted* Add F - for fitted
MxPro 4 Mounting BezelsMXM-001 Semi-flushing bezel for Mx-4100MXM-002 Semi-flushing bezel for Mx-4200/Mx-4400MXM-008 Semi-flushing bezel for Mx-4010/Mx-4020MXM-032 Semi-flushing bezel for Mx-4800MXM-037 Semi-flushing bezel for Mx-4100/LMXM-048 Semi-flushing double bezel for 2 multi-loop panels side-by-sideMXM-054(F)* 19" rack mounting bezel (6U high) for a 50, 100 or 200
zone LED card MXM-054-001(F)*
19" rack mounting bezel (300mm) for a 50,100, 200 zone LED card
MXM-057 Spare 19" rack mounted adaptor plate for Mx-4400 chassis* Add F - for fitted
27
Product Code Description
MxPro 4 Lexan (Plexi glass) Door Kits
MXM-007 Lexan door kit for Mx-4200/Mx-4400
MXM-007F* Lexan door kit for Mx-4200/Mx-4400 - fitted
MXM-041 Lexan door kit for Mx-4800
MXM-041F* Lexan door kit for Mx-4800 - fitted
replace* 001 c/w Printer cut-out
with 002 c/w Printer cut-out and key switch
or 003 c/w Key switch cut-out
MXM-059 Full Lexan deep over door kit for Mx-4200/Mx-4400
MXM-059F Full Lexan deep over door kit for Mx-4200/Mx-4400 - fitted
MXM-059-001 Full Lexan deep over door kit with alternate key for Mx-4200/Mx-4400
MXM-059-001F Full Lexan deep over door kit with alternate key for Mx-4200/Mx-4400 - fitted
* Add F - for fitted
MxPro 4 Enclosures, blanking plates and spare doors
MXM-018 Spare back-box for Mx-4100
MXM-018-002 Spare back-box for Mx-4100 without transformer
MXM-038 Spare back-box for Mx-4100/L
MXM-017 Spare back-box for Mx-4200/Mx-4400
MXM-020 Spare deep back-box for Mx-4200/Mx-4400
MXM-042 Spare back-box for Mx-4800
MXM-030 Spare back-box for Mx-4010/Mx-4020
MXM-058 Spare deep back-box for Mx-4010/Mx-4020
MXM-019 Utility enc. matching Mx-4200/Mx-4400
MXM-019-D Deep utility enc. matching Mx-4200/Mx-4400/D
MXM-052 Utility enc. matching Mx4100/L
MXM-028 Termination enc. - 1-4 loop panel
MXM-029 Termination enc. - 1-8 loop panel
MXM-043 Document enc.
MXM-061 Large document enc.
MXM-046 Spare Mx-4100/L enc. and door
MXM-040 Spare enc. c/w door for Mx-4200/Mx-4400
MXM-044 Spare enc. for modem or BMS interface
MXM-049 Spare lid for Mx-4100
MXM-039 Spare door for Mx-4100/L
MXM-047 Spare door for Mx-4200/Mx-4400
MXM-047-001 Spare door (double aperture) for Mx-4200/Mx-4400
MXM-031 Blanking plate for lower apeture on Mx-4200/Mx-4400 door
MXM-053 Spare blank deep panel door c/w lock for Mx-4400
MXM-053F Blank deep panel door for Mx-4200/4400 - fitted
MXM-045 Spare lid for Mx-4010/4020
MXM-050 Spare door for Mx-4800
MXM-051 Spare upper aperture blanking plate for Mx-4800 enc.
MXM-060 Spare Mx-4800 enc. assembled
Product Code Description
MxPro 4 Special Finishes
MXM-009 (F)* Stainless steel door for Mx-4400/Mx-4200
MXM-009-001 (F)*
Stainless steel door (double aperture) for Mx-4400/ Mx-4200
MXM-010 Stainless Steel bezel for Mx-4400/Mx-4200
MXM-011 (F)* Chrome door for Mx-4200 / Mx-4400
MXM-011-001 (F)* Chrome door (double aperture) for Mx-4200/ Mx-4400
MXM-012 Chrome bezel for Mx-4200/Mx-4400
MXM-013 (F)* Chrome door for Mx-4100
MXM-014 Chrome bezel for Mx-4100
MXM-015 (F)* Stainless steel door for Mx-4100
MXM-016 Stainless steel bezel for Mx-4100
MXM-021 (F)* Chrome door for Mx-4010/Mx-4020
MXM-022 Chrome bezel for Mx-4010/Mx-4020
MXM-023 (F)* Stainless steel door for Mx-4010/Mx-4020
MXM-024 Stainless steel bezel for Mx-4010/Mx-4020
MXM-055 (F)* Stainless steel door for Mx-4100/L - fitted
MXM-056 Stainless steel bezel for Mx-4100/L
* Add F - for fitted
MxPro 4 Spares
MXS-001 Spare Mx-4100 single loop base card
MXS-002 (N) (V)* Spare Mx-4200 1 - 2 loop base card (*Add N for Nittan Evolution or V for AV protocol)
MXS-003 (N) (V)* Spare Mx-4400 1 - 4 loop base card (*Add N for Nittan Evolution or V for AV protocol)
MXS-004 Spare Mx-4000 graphic display card
MXS-005 Spare power supply unit for Mx-4400
MXS-006 Spare power supply unit for Mx-4200
MXS-008 Spare paper roll for Mxp-012 printer (pack of 10)
MXS-009-050 Spare 50 zone LED card
MXS-009-100 Spare 100 zone LED card
MXS-010 BMS/graphics network interface card
MXS-011 Spare panel door key
MXS-012 Spare access enable key
MXS-013 Spare panel lock and key
MXS-019 8-way input /output card (Hochiki protocol)
MXS-021 4-way sounder splitter card
MXS-024 20 Zone LED Card (PCB only)
MXS-025 5A Sounder booster card
MXS-027 Local 100 zone mimic driver card
MXS-028 Spare peripheral fault tolerant network interface
MXS-029 Spare 10-way earthing block for Mx-4200/Mx-4400/ Mx-4800
MXS-034 2-way pluggable lead for key switch input card
MXS-030 Non-illuminated push button + 450mm long 2-way cable
MXS-030-R Illuminated (red) push button + 450mm long 2-way cable
MXS-030-G Illuminated (green) push button + 450mm long 2-way cable
MXS-038-xxx 20-way ribbon cable (xxx = 320, 550, 650mm)
MXS-039-xxx Cable, 2-way plug to plug (xxx = 320, 550, 650mm)
MXS-049 Spare 24V 1.5A EN54-4 PSU and battery charger card
MXS-050 Spare 24V 3A EN54-4 PSU and battery charger card
MXS-051 Spare 24V 5A EN54-4 PSU and battery charger card
MXS-055 Spare key for Mxm-059-001 Lexan door kit (alternate key)
MXS-056 Spare lock and key for Mxm-059-001 Lexan door kit (alternate key)
MXS-057 Spares kit for Mx-4200/Mx-4400
MXS-058 Spare transformer assembly for Mx-4100
SSD
2081 [
Editi
on 5
]
The Standard in Fire Systems
EMEAA HQ Moorland Way, Cramlington, Northumberland NE23 1WE UK Tel: +44 (0)1670 707 111 Fax: +44 (0)1670 707 222
Dubai Office Dubai Airport Free Zone, Building W3, Office 211, Dubai UAE Tel: +971 4 299 0908 Fax: +971 4 299 0554
Email: [email protected] Web: www.advancedco.com