the light ion guide cb- ecris project at texas a&m university

15
The Light Ion Guide CB- ECRIS Project at Texas A&M University Cyclotron Institute The Light Ion Guide CB- ECRIS Project at Texas A&M University Cyclotron Institute G. Tabacaru (TAMU) , J. Arje (Jyvaskyla), D.P. May (TAMU) G. Tabacaru (TAMU) , J. Arje (Jyvaskyla), D.P. May (TAMU)

Upload: others

Post on 11-Sep-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Light Ion Guide CB- ECRIS Project at Texas A&M University

The Light Ion Guide CB-ECRIS Project at Texas A&MUniversity Cyclotron Institute

The Light Ion Guide CB-ECRIS Project at Texas A&MUniversity Cyclotron Institute

G. Tabacaru (TAMU), J. Arje (Jyvaskyla), D.P. May (TAMU)G. Tabacaru (TAMU), J. Arje (Jyvaskyla), D.P. May (TAMU)

Page 2: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Project overviewProject overview

Cyclotron Institute Texas A&M:• 88” Cyclotron (decommissioned1986)• K500 Superconducting Cyclotron

Upgrade started 2004 → full speed 2005

Re-activation of 88” Cyclotron – deliverhigh intensity light particle and heavy ionbeams.

Production of rare isotopes for accelerationin K500 Superconducting Cyclotron andhigher intensity stripping and fragmentationbeams.

G. Tabacaru, ECRIS 08, Chicago

Page 3: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Scientific programScientific program

1. Nuclear Astrophysics:a. Radioactive beams from K500: Asymptotic Normalization

Coefficients methodb. Stable beams from 88”: (3He,d) reactions and MDM

spectrometer2. Nuclear Structure:

a. Giant Monopole Resonance and Compressibility: GMR asa nuclear structure effect and compressibility in nucleiwith much higher asymmetry

b. Cluster Structure: radioactive beams and thick targetinverse kinematics technique

3. Fundamental Interactions: superallowed β-decaymeasurements

4. Nuclear Dynamics and Nuclear Thermodynamics

Page 4: The Light Ion Guide CB- ECRIS Project at Texas A&M University

RF-only hexapole

Target ChamberHe ~ 300 – 500 mbar

~ 1mbar

~10-2mbar

~10-6mbar

Faraday Cup

Glaser lens

The Light Ion GuideThe Light Ion Guide

to CBECR

In collaboration with Dr. J. Arje - Jyvaskyla

proton beam

G. Tabacaru, ECRIS 08, Chicago

Page 5: The Light Ion Guide CB- ECRIS Project at Texas A&M University

4×10526110In (4.9h)

2×10528108In (58.0m)

4×10528106In (6.20m)

2×1053592Tc (4.25m)

2×1054564Ga (2.63m)

4×1044554Co (0.19s)

1×1054550Mn (0.28s)

4×1045727Si (4.16s)

particles/sMeV/AProduct (T1/2)

IntensityMax Energy(p,n)

Projected beam intensities from LIGafter K500

Projected beam intensities from LIGafter K500

G. Tabacaru, ECRIS 08, Chicago

Page 6: The Light Ion Guide CB- ECRIS Project at Texas A&M University
Page 7: The Light Ion Guide CB- ECRIS Project at Texas A&M University

The RF-only hexapoleThe RF-only hexapole

SIMION calculations ~ 80% efficiency for 250 cm long sextupole

G. Tabacaru, ECRIS 08, Chicago

Page 8: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Details – Light Ion GuideDetails – Light Ion Guide

Parameters: exit hole diameter (1 mm and 2 mm), pressure, DC-fields,distance between the exit hole and the sextupole, etc …

Pumping system (Pfeiffer):• ROOTS blower 1: 2000 m3/h (+ 6000 m3/h – online condition)• ROOTS blower 2: 1000 m3/h• Turbo pumps: 520 l/s + 2× 520 l/s (CB-ECRIS)

Initial developments:• spark chamber (ionization of impurities, He) → current• 228Th open source (daughters) → alpha particles from 216Po

G. Tabacaru, ECRIS 08, Chicago

Page 9: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Details – CB-ECRISDetails – CB-ECRIS

Design and built by Scientific Solutionsof San Diego, California Operate at 14.5 GHz Two large coils: max ~ 1T Hexapole Nd-Fe-B: ~1.1T

hexapole

axial coil

Electrodesforinjection

WORK IN PROGRESS !!!0

0.5

1.0

1.5

2.0

-15 -10 -5 0 5 10 15

AMPERESData

Axial Displacement(inches)

Mag

netic

Fie

ld(k

Gau

ss)

Charge-Breeder Solenoid QAFinal Magnet Configuration @50 Amps

5-JAN-07

-20

-10

0

10

20

0 90 180 270 360

y = a*sin(b*x+c) max dev:2.1903, r2=0.99384a=11.533, b=3.0093, c=-0.67063

Rotation Angle

Rad

ialM

agne

ticF

ield

(kG

auss

)

TAMU SextupoleInitial QA Checkout

5-JAN-07

G. Tabacaru, ECRIS 08, Chicago

Page 10: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Tests – spark chamberTests – spark chamber

Ifc, Isp vs Ptc

0

2

4

6

8

10

12

14

0 100 200 300 400 500

Ptc [mbar]

Ifc

[nA

]

Ifc [nA]Isp [x0.33mA]

LIG-SP100cm9-Oct-07

Øe = 1.0mmXes ≈ 3.5mmØelectrode =4mmXrods ≈ 29mmIsp = (1.07-1.23)*3.3mAf = 3.485MHzVrf = 6.0V (gen.)Velectrode=floatingVtc = Vrf,dc togetherVsp = 227 VI-Glazer = 0

Ifc vs. +Vfc vs. Ve

0

5

10

15

20

25

30

0 50 100 150 200Vfc [V]

Ifc

[nA

]

Ifc [nA], Ve=+202VIfc [nA], Ve floatsSIMION normalized

LIG27-Jun-07Øe =2.0mmØelectrode =4mmXes ˜ 3.5mmIsp =0.15*3.3mAVsp =238VIfc =ave/100samplesf =5.630MHzVrf =10.0V (gen.)Vtc =-Vrf,dc =8.5VPtc =170mbar

SSmesh 0.8x0.8mm2inside sp-chamber

-->no effect

G. Tabacaru, ECRIS 08, Chicago

Page 11: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Plasma chamber

Microwave 14.5 GHz

Sextupole

Tests – 228Th open sourceTests – 228Th open source

Si det

Aluminized mylar 1.5 µmAluminized mylar 1.5 µm

Ra, Rn, Po

G. Tabacaru, ECRIS 08, Chicago

Page 12: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Tests – 228Th open sourceTests – 228Th open source

• Partially simulate the online conditions• Lower final velocity at the injection in the CB-ECRIS• Alpha particle detection necessary – difficult to fine tune

228Th and daughters alpha spectra

228Th

216Po

212Po

216Po approx 100 α/sec216Po approx 100 α/sec

backgroundbackground

Page 13: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Velocity of the ionsVelocity of the ions

0

5

10

15

20

25

30

35

40

45

50

-40 -20 0 20 40 60 80

Retarding bias [V]

Yie

ld[a

lph

as/s

ec]

approx 20-25 eV

Q: Is this velocity appropriate for an efficient injection in the CB-ECRIS?Q: Is this velocity appropriate for an efficient injection in the CB-ECRIS?

G. Tabacaru, ECRIS 08, Chicago

Page 14: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Future plansFuture plans

CB-ECRIS to be turned on in the next weeks TWT – max 400 W coils at 250 A plasma?!

Inject Ra, Rn, Po Detect alphas at the extraction

IF success GOTO Improve_EfficiencyELSE

Find Stable Conditions for CB-ECRIS

Measure the overall efficiency of the device

CB-ECRIS to be turned on in the next weeks TWT – max 400 W coils at 250 A plasma?!

Inject Ra, Rn, Po Detect alphas at the extraction

IF success GOTO Improve_EfficiencyELSE

Find Stable Conditions for CB-ECRIS

Measure the overall efficiency of the device

G. Tabacaru, ECRIS 08, Chicago

Page 15: The Light Ion Guide CB- ECRIS Project at Texas A&M University

Upgrade TeamUpgrade TeamDr. R.E. Tribble - director

Dr. H. Clark – Project Manager

F. Abegglen – Operation ChiefH. Peeler – Research

Instrumentation

K150 – Re-commission Light Ion Guide &Heavy Ion Guide

Managers

Dr. G. TabacaruDr. G. ChubaryanDr. G. Souliotis

CBECR &New beam lines

Dr. D. MayDr. G. Kim

Radiation issues &Beam dump

Dr. G. TabacaruThank you!

G. Tabacaru, ECRIS 08, Chicago