the new standardmay 23, 2013  · by far the most important credit in leed, based on the number of...

2
8000 Norman Center Drive, Suite 640 - Minneapolis, MN 55437 phone: 877-300-3948 - fax: 952-224-2446 EcoSmartExits.com THE NEW STANDARD LEED CREDITS EAc1: Optimize Energy Performance By far the most important credit in LEED, based on the number of points available NC-2009 / NC-v2.2 / EBOM-2009 / CS-2009 / Schools-2009 EAc1.1: Optimize Energy PerformanceLighting Power Projects earn points by reducing lighting power density for interior spaces CI-2009 EAp2: Minimum Energy Performance Mandatory and performance based requirements that provide environmental benefits as well as operational cost savings NC-2009 / NC-v2.2 / CI-2009 / CS-2009 / Schools-2009 EAp2: Minimum Energy Efficiency Performance All LEED for Existing Buildings: Operations & Maintenance projects have to earn this prerequisite EBOM-2009 “At roughly the same initial cost as an LED sign, LEC has an instant economic payback.” Achieving 50% Energy Savings Toward a Net Zero Energy Building, Advanced Energy Design Guide (AEDG) AEDG developed by: ASHRAE The American Institute of Architects Illuminating Engineering Society of North America U.S. Green Building Council U.S. Department of Energy FEATURES LEC: The New Standard for Energy Efficiency Less than 1/4 Watt AC Energy Draw Unsurpassed Illumination Uniformity Produces the most uniform and solid state light which re- sults in superior readability Compliant with Safety Codes LEC light source does not fail catastrophically; no variation in luminance; meets or exceeds UL 924 standards, NFPA 101 Life Safety Code and National Electrical Code Sustainable Operation No bulbs to replace, no inventory management, fully recy- cled housing, LEC panel replacement program and low car- bon footprint Installs in Just Minutes Universal mount canopy included Slim Profile Housing—Only 5/8” thick High Cost Effectiveness Qualifies for rebates, measurable operational savings; lower cost of ownership

Upload: others

Post on 14-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THE NEW STANDARDMay 23, 2013  · By far the most important credit in LEED, based on the number of points available NC-2009 / NC-v2.2 / EBOM-2009 / CS-2009 / Schools-2009 ... 101 …

8000 Norman Center Drive, Suite 640 - Minneapolis, MN 55437 phone: 877-300-3948 - fax: 952-224-2446

EcoSmartExits.com

THE NEW STANDARD

LEED CREDITS EAc1: Optimize Energy Performance

By far the most important credit in LEED, based on the number of points available

NC-2009 / NC-v2.2 / EBOM-2009 / CS-2009 / Schools-2009

EAc1.1: Optimize Energy Performance—Lighting Power

Projects earn points by reducing lighting power density for interior spaces

CI-2009

EAp2: Minimum Energy Performance

Mandatory and performance based requirements that provide environmental benefits as well as operational cost savings

NC-2009 / NC-v2.2 / CI-2009 / CS-2009 / Schools-2009

EAp2: Minimum Energy Efficiency Performance

All LEED for Existing Buildings: Operations & Maintenance projects have to earn this prerequisite

EBOM-2009

“At roughly the same initial cost as an LED sign, LEC has an instant economic payback.” —Achieving 50% Energy Savings Toward a Net Zero Energy

Building, Advanced Energy Design Guide (AEDG)

AEDG developed by: ASHRAE The American Institute of Architects Illuminating Engineering Society of North America U.S. Green Building Council U.S. Department of Energy

FEATURES LEC: The New Standard for Energy Efficiency

Less than 1/4 Watt AC Energy Draw

Unsurpassed Illumination Uniformity

Produces the most uniform and solid state light which re-sults in superior readability

Compliant with Safety Codes

LEC light source does not fail catastrophically; no variation in luminance; meets or exceeds UL 924 standards, NFPA 101 Life Safety Code and National Electrical Code

Sustainable Operation

No bulbs to replace, no inventory management, fully recy-cled housing, LEC panel replacement program and low car-bon footprint

Installs in Just Minutes

Universal mount canopy included

Slim Profile Housing—Only 5/8” thick

High Cost Effectiveness

Qualifies for rebates, measurable operational savings; lower cost of ownership

Page 2: THE NEW STANDARDMay 23, 2013  · By far the most important credit in LEED, based on the number of points available NC-2009 / NC-v2.2 / EBOM-2009 / CS-2009 / Schools-2009 ... 101 …

8000 Norman Center Drive, Suite 640 - Minneapolis, MN 55437 phone: 877-300-3948 - fax: 952-224-2446

EcoSmartExits.com

TYPE:_______________________________ CATALOG #:__________________________ NOTES:______________________________

ST

SERIES PANEL MOUNT OPERATION FACES MOUNT OPTIONS

Standard (Black or white)

AR Architectural (Brushed nickel or mirror)

BL Black

WH White

BN Brushed Nickel

MR Mirror

WH White

BL Black

BB Battery backup manual testing

AC AC Power

DS Double Sided

SS Single-side

B Back

R Right Side

L Left Side

T Top C Configured in field (white and black only)

B Both

R Right

L Left

N None

CODE COMPLIANCE ETL Listed to Meet UL 924 and NFPA Life Safety Code 101 Requirements. The LEC sign is also ARRA and Buy American Compliant.

WARRANTY Eight year product warranty against manufacturing defects subject to proper installation and maintenance.

HOW TO ORDER AR - BN - WH - BB - SS - T - L - S architectural series, brushed nickel finish with white trim, AC with battery backup, single sided, top mount, left chevron with self

diagnostic

S Self diagnostics

DIMENSIONS

CHEVRONS

INSTALLATION Two wire nuts and two screws

Universal mounting bracket for a 4x4 junction box

Luminary disconnect available for easy retrofit

ELECTRICAL SPECIFICATIONS Utility Input: 120/277 VAC, 60 Hz Temperature Range: 50º

F (10º C) to 104º F (40º C) Recharge Duty Cycle: 24 hours Battery Type: Rechargeable Nickel Metal Hydride Safety Circuitry: Solid State Transfer, Surge Protection