THE POWER OF MASS SPECTROMETRY FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities with Enhanced Detection for IC Applications

Upload: truongthu

Post on 19-Apr-2018

227 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

THE POWER OF MASS SPECTROMETRY FOR IC ANALYTICAL CHEMISTS

Unleash New Possibilities

with Enhanced Detection for IC Applications

Page 2: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

THE POWER OF MASS SPECTROMETRYIon chromatography (IC) excels in analyzing ionic species—analytes of major importance to environmental, food and beverage, pharmaceutical, life science, chemical, power generation, and electronics industries. As the ion chromatography innovator and technology leader for over 40 years, Thermo Fisher Scientific understands what IC analytical chemists need for their work.

There is a continuing need for today’s researcher to detect small quantities of analytes in complex samples. But what if you need even lower levels of sensitivity and selectivity to add extra confidence to your results?

Unleash New Possibilities with Enhanced Detection for IC Applications Combining ion chromatography (IC) with mass spectrometry (MS) maximizes the power to detect unexpected coelutions of components and confirm trace components with the analytical confidence of mass spectrometry. Mass spectrometry dramatically improves your IC system capabilities and provides:

• Higher sensitivity and accurate quantitation• Peak confirmation and evaluation of chromatographic peak purity• Improved resolution of complex samples• Seamless integration of MS data into your IC workflow

Page 3: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

Coupling IC to MS

IC-MS is a recommended method for sensitive and selective determinations of ions. Combining ion chromatography with MS workflows increases efficiency and sensitivity, and improves resolution in complex samples, leading to more accurate quantitation, improved confidence, and more chemical information about every sample.

Thermo Fisher Scientific offers several different mass spectrometer options for IC systems:

• single quadrupole MS

• triple quadrupole MS

• high resolution-accurate mass (HRAM) hybrid quadrupole-Orbitrap MS

As the capabilities of these instruments grow, so does their power to provide information about your compounds of interest. While a single quadrupole MS adds sensitivity and peak confirmation to your analyses, a triple quadrupole MS/MS provides additional sensitivity, peak confirmation, and basic structural elucidation. HRAM Orbitrap MS adds advanced structural elucidation to IC-MS analyses.

Page 4: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

MORE CONFIDENCE

Higher Sensitivity and Accurate QuantitationFor routine analyses where single digit parts-per-billion (ppb) sensitivities are required, a simple mass detector, such as a single quadrupole mass spectrometer, offers the required sensitivity. Mass detection adds confidence to your quantitation, enabling you to obtain limits of detection (LODs) at least an order of magnitude greater than those provided by conductivity detection.

With the use of very specific MS selected ion monitoring (SIM) detection, ppb-level quantification can be performed with greater confidence on a wide range of real-world samples, such as bottled drinking water.

0 250 500 750 1000 1200

0

20000

40000

60000

80000

100000

120000

140000counts*min

tartrate External tartrate

Calibration curve of tartrate at concentrations from 2 ppb to 1000 ppb, r2=0.9998 Anions in a bottled water sample

0 5.0 10.0 15.0 19.70.0e0

1.2e6

Minutes

0

80,0000

30,000

Inte

nsity

(cou

nts)

Chloride

SIM = m/z 35.1

SIM = m/z 62.1

Nitrate

Sulfate

Phosphate

SIM = m/z 97.1

Page 5: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

MORE CONFIDENCEPeak ConfirmationIn addition to the enhanced detection, if your study requires peak confirmation or peak purity analysis the single quadrupole MS detector such as the Thermo Scientific™ ISQ™ EC mass spectrometer will provide complementary molecular weight data, for an increased degree of confidence.

99.50 100 102.50 -20

0

60

120

101.0

Q u a n

m/z

%

Apex 101 perchlorate Scan: #2202 RT:...

0.0-2000

0

4000

8000

12000

2.0 6.0 10.0 14.0

Perchlorate

AB

C

AN151 conditions, IonPac AS20 column, 100 µL injection, without desolvation solvent

0.040

0.026

µS-min

Suppressed Conductivity

1700

800

Counts-min

ISQ EC, SIM

ISQ EC, SIM 2000

1650

Counts-min

Perchlorate, m/z 99

6.7 16 Min

m/z 101

Perchlorate?

Determination of perchlorate in a Municipal Drinking Water Sample. (A) The conductivity channel provides very limited sensitivity towards the perchlorate peak and no confirmatory data. (B) SIM m/z 99 provides a very sensitive response towards perchlorate. (C) SIM m/z 101 confirms the response as perchlorate by confirming the 3:1 ratio of m/z 99:101 expected for perchlorate.

Where unknown chromatographic peaks appear, mass detection enables the IC analytical chemist to quickly and effectively suggest a number of possibilities for these unknown peaks. By scanning across a chromatographic peak with a mass detector, it is possible to detect the appearance of unusual masses.

Page 6: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

Dionex ICS-6000 HPIC system: A modular, highly flexible IC system designed to meet the widest range of applications.

Dionex Integrion HPIC system A compact, integrated IC system for routine ion analysis demands, ease-of-use and reliability.

Thermo Scientific™ ISQ™ EC

Single Quadrupole Mass

Spectrometer: An economical, benchtop mass detector designed for routine IC-MS workflows.

FLEXIBLE IC-MS COMBINATIONSThermo Fisher Scientific offers two different IC systems, the Thermo Scientific™ Dionex™ ICS-6000 HPIC™ system and the Thermo Scientific™ Dionex™ Integrion™ HPIC™ system, suited for pairing with MS detection. Each of these unique IC systems can be used with a variety of mass spectrometers, offering increasing levels of confidence, peak confirmation, and structural elucidation for your analyses.

Page 7: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

Thermo Scientific™ ISQ™ EC

Single Quadrupole Mass

Spectrometer: An economical, benchtop mass detector designed for routine IC-MS workflows.

Thermo Scientific™ TSQ Altis™

and Thermo Scientific™ TSQ

Quantis™ Triple Quadrupole

Mass Spectrometers: Best-in-class benchtop MS designed for quantitative performance, robustness, and value.

Thermo Scientific™ Orbitrap Fusion™ Mass Spectrometer: An instrument combining the best of quadrupole, ion trap and Orbitrap mass analysis and ease of use for the highest performing research system particularly suited for life science applications.

Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap Mass Spectrometer: High-resolution, accurate-mass (HRAM) benchtop MS that delivers high resolution data for quantitative, screening and confirmation studies.

Mass Spectrometer Analyzer Mode of Operation MS MS/MS Sensitivity Peak Confirmation

Structural Elucidation

ISQ EC Quadrupole Single ion monitoring (SIM)

TSQ Quantis MS Triple Quadrupole Selected reaction monitoring (SRM)

TSQ Altis MS Triple Quadrupole Selected reaction monitoring (SRM)

Q Exactive MS Orbitrap mass analyzer High Resolution Accurate Mass (HRAM)

Orbitrap Fusion MS Orbitrap mass analyzer High Resolution Accurate Mass (HRAM)

Page 8: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

RESOLVING COMPLEXITY

Increased Selectivity for Complex Samples When you need increased sensitivity and peak confirmation, the increased power of a triple quadrupole MS may be the answer. The sensitivity and selectivity of MS/MS detection makes it a highly preferred method for complex sample matrices. For example, perchlorate in baby formula can be quantified, without enrichment at low parts-per-trillion (ppt) levels using simple sample preparation and a TSQ Altis triple quadrupole mass spectrometer for detection. This system provides excellent reproducibility, accuracy, and precision.

0 4 8 12 14Time (min)

0

60

100

0

60

100

Rela

tive

Abun

danc

e

0

60

100

0 4 8 12 14

Time (min)

0

60

100

0

60

100

Rela

tive

Abun

danc

e

0

60

100

RT: 11.59AA: 227857SN: 21147

Infant Formula Milk

m/z 99 ( 35ClO 4-) → m/z 83 ( 35ClO 3

-)

Perchlorate by 99

m/z 101 ( 37ClO 4-) → m/z 85 ( 37ClO 3

-)

Perchlorate by 101

m/z 107 ( 35Cl 18 O 4-) → m/z 89 ( 35 Cl 18O 3

-)

Internal Standard

m/z 99 ( 35ClO 4-) → m/z 83 ( 35ClO 3

-)

Perchlorate by 99

m/z 101 ( 37ClO 4-) → m/z 85 ( 37ClO 3

-)

Perchlorate by 101

m/z 107 ( 35Cl 18 O 4-) → m/z 89 ( 35 Cl 18O 3

-)

Internal Standard

Perchlorate in unspiked infant formula and milk samples. Calculated concentrations are in the 1–5 µg/L range.

Page 9: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

Selectivity for Co-Eluting Peaks Combining ion chromatography with mass spectrometric detection offers great selectivity. In the example to the right, organic acids were analyzed by IC-MS. Using MS detection, each of these organic acids was observed as a single peak. By overlaying the individual responses for each recorded mass, it is possible to determine how the co-eluting organic acids contribute to the total chromatographic peak.

nte

tens

ity(c

ount

s)R

espo

nse

(µS

)

0 2 4 6 8 10 11

0

350,000

minute

0

300,000

RT: 4.79 - Malate

- A

rea: 42o18

RT: 9.46 - Citra

te

-

Area: 55471

0

250,000

RT: 4.77 - S

ucchate

- A

rea: 34718

RT: 3.58 - pyry

vate

- A

rea: 16652

0

50000120,000

-1.50

-0.40

RT: 4.79 - Succinate/Malate

RT: 9.46 - Citra

te

RT: 3.58 - pyry

vate

Pyruvate SIM 87

Succinate SIM 117

Malate SIM 133

Citrate SIM 191

Standard mix at 0.5 mg/L level

B

A

30,000

18,000 0

0

70,000 -5.0

45.0

Citrate, m/z 191

Lactate, m/z 89

0 5 10 15 20 25 30 35 40 45

0

7,000 0

25,000 0

Malate, m/z 133

Malonate, m/z 103

Succinate, m/z 117

Animal feed Sample

Res

pons

e (µ

S)

minute

Inte

tens

ity(c

ount

s)

Determination of organic acids in Animal Feed by single quadrupole IC-MS. (A) The conductivity channel provides sufficient response for the organic acids, but lacks resolution for malate, malonate and succinate. (B) The highly selective SIM channels on the Thermo Scientific ISQ EC are able to respond individually to the three co-eluting organic acids, providing both quantitative and qualitative data.

Page 10: The Power of Mass Spectrometry for IC Analytical Chemists ... · FOR IC ANALYTICAL CHEMISTS Unleash New Possibilities ... for life science ... Chemists Unleash New Possibilities with

IC-MS Analysis Software Thermo Scientific offers a range of software solutions to support IC-MS applications.

• Thermo Scientific™ Chromeleon™ Chromatography Data System (CDS) software is ideal for routine quantitative workflows.

• Thermo Scientific™ TraceFinder™ and/or Thermo Scientific™ Xcalibur™ software is recommended for qualitative workflows.

Find out more at thermofisher.com/ICMS

© 2018 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. BR72088-EN 0218S

90 110 130 150 170 m/z

0

20

40

60

80

100

Relat

ive A

bund

ance

(M-H)-

139.0166

133.0507 110.9853

120 130 140 150 160 170 180 m/z

0

20

40

60

80

100

Relat

ive A

bund

ance

(M-H)-

139.0071

141.0029

50 70 90 110 130 150m/z

0

20

40

60

80

100

Relat

ive A

bund

ance

78.95910

2P

0.8 ppm

110.9853C H

4 0

4P

0.5 ppm

(-) C3H

8O

4P

m/z (-) 139.01660.4 ppm

C3H

7O

4S

m/z (-) 139.00710.3 ppm

139.0166C

3 H

4 0

4P

0.5 ppm

62.96420

2P

0.3 ppm

50 70 90 110 130 150m/z

0

20

40

60

80

100

Relat

ive A

bund

ance

139.0072C

3 H

7 O

4 S

1.0 ppm79.9575O

3 S

1.3 ppm

81.953264.9702HO

2 S

-1.4873 ppm

120.9965C

3 H

5 O

3 S

-0.1060 ppm

MS/MS MS/MS

S

O

O

OOHOH P

O

O

O

HRAM MS/MS fragments facilitate identification of unknown compounds.

Structural Elucidation Capabilities IC combined with high-resolution, accurate-mass (HRAM) Orbitrap mass spectrometry is an ideal solution for component identification in non-targeted and unknown workflows. For example, identification of lithium-ion battery failure analysis products using HRAM MS/MS offers four-decimal-point accuracy to distinguish between species. The unique fragmentation signature enhances that confidence. In addition to validating a proposed degradation pathway, confidence in the results avoids spending research time and resources going in an unproductive direction.