the roof deck you need for your next …...long span deck type ls6 technical data depth 6” rib...
TRANSCRIPT
THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT
For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049
www.canam-construction.com
1PRODUCT DATASHEETRoof Deck Type H6
Long Span Deck Type H6Technical Data
Depth 6”
Rib width 9”
Fy 40 ksi
Cover width 12”
Product
Options available:CellularAcousticCellular/acoustic
Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available
GageSection properties*
Wt (psf)
Ip (in4)
In (in4)
Sp (in3)
Sn (in3)
18 4.3 6.69 7.41 1.97 2.05
16 5.5 8.76 9.43 2.61 2.67
* Ip, In, Sp and Sn are the section properties per foot of width.
GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection
16'-0'' 17'-0'' 18'-0'' 19'-0'' 20'-0'' 21'-0'' 22'-0'' 23'-0'' 24'-0''
18 124 / 107 117 / 89 111 / 75 105 / 64 100 / 55 95 / 47 91 / 41
16 200 / 140 188 / 117 178 / 98 168 / 84 154 / 72 140 / 62 127 / 54 117 / 47 107 / 41
Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.
9”
6”
12” Cover
THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT
For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049
www.canam-construction.com
2PRODUCT DATASHEETRoof Deck Type H7.5
Long Span Deck Type H7.5Technical Data
Depth 71⁄2”
Rib width 9”
Fy 40 ksi
Cover width 12”
Product
Options available:CellularAcousticCellular/acoustic
Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available
GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection
20'-0'' 21'-0'' 22'-0'' 23'-0'' 24'-0'' 25'-0'' 26'-0'' 27'-0'' 28'-0''
18 90 / 92 86 / 79 82 / 69 78 / 60 75 / 53
16 153 / 120 146 / 104 140 / 90 133 / 79 128 / 70 123 / 62 118 / 55 113 / 49 105 / 44
Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.
GageSection properties*
Wt (psf)
Ip (in4)
In (in4)
Sp (in3)
Sn (in3)
18 4.80 11.21 12.11 2.65 2.64
16 6.10 14.70 15.56 3.54 3.47
* Ip, In, Sp and Sn are the section properties per foot of width.
9”
7½”
12” Cover
THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT
For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049
www.canam-construction.com
3PRODUCT DATASHEETRoof Deck Type J4.5
Long Span Deck Type J4.5Technical Data
Depth 41⁄2”
Rib width 9”
Fy 40 ksi
Cover width 12”
Product
Options available:CellularAcousticCellular/acoustic
Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available
GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection
11'-0'' 12'-0'' 13'-0'' 14'-0'' 15'-0'' 16'-0'' 17'-0'' 18'-0'' 19'-0''
20 99 / 112 91 / 86 84 / 68 78/ 54
19 141 / 137 130 / 106 120 / 83 111 / 67 104 / 54 97 / 45
18 187 / 163 172 / 125 159 / 99 147 / 79 133 / 64 117 / 53 104 / 44
16 299 / 217 268 / 167 229 / 132 198 / 105 172 / 86 152 / 71 135 / 59 120 / 50 108 / 42
Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.
GageSection properties*
Wt (psf)
Ip (in4)
In (in4)
Sp (in3)
Sn (in3)
20 2.8 2.28 2.73 0.88 0.97
19 3.3 2.79 3.20 1.10 1.17
18 3.8 3.31 3.63 1.27 1.35
16 4.8 4.42 4.57 1.64 1.71
* Ip, In, Sp and Sn are the section properties per foot of width.
9”
4½”
12” Cover
THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT
For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049
www.canam-construction.com
4PRODUCT DATASHEETRoof Deck Type LS4.5
Long Span Deck Type LS4.5Technical Data
Depth 41⁄2”
Rib width 81⁄8”
Fy 40 ksi
Cover width 12”
Product
Options available:CellularCellular/acoustic
Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available
GageSection properties*
Wt (psf)
Ip (in4)
In (in4)
Sp (in3)
Sn (in3)
16 4.90 4.84 4.86 1.94 2.00
14 6.10 6.06 6.06 2.46 2.49
12 8.60 8.45 8.45 3.44 3.44
10 11.00 10.82 10.82 4.38 4.38
* Ip, In, Sp and Sn are the section properties per foot of width.
GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection
17'-0'' 18'-0'' 19'-0'' 20'-0'' 21'-0'' 22'-0'' 23'-0'' 24'-0'' 25'-0''
16 159 / 64 142 / 54 127 / 46
14 202 / 81 180 / 68 162 / 58 146 / 50 133 / 43
12 282 / 113 252 / 95 226 / 81 204 / 69 185 / 60 169 / 52 155 / 45 142 / 40
10 359 / 144 320 / 121 288 / 103 260 / 88 236 / 76 215 / 66 197 / 58 181 / 51 167 / 45
Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.
81/8”
12” Cover
4½”
Long Span Deck Type LS6Technical Data
Depth 6”
Rib width 81⁄8”
Fy 40 ksi
Cover width 12”
Product
THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT
For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049
www.canam-construction.com
5PRODUCT DATASHEETRoof Deck Type LS6
Options available:CellularCellular/acoustic
Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available
GageSection properties*
Wt (psf)
Ip (in4)
In (in4)
Sp (in3)
Sn (in3)
16 5.50 9.45 9.52 2.85 3.00
14 6.90 11.87 11.87 3.70 3.74
12 9.60 16.55 16.55 5.18 5.18
10 12.40 21.19 21.19 6.60 6.60
* Ip, In, Sp and Sn are the section properties per foot of width.
GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection
23'-0'' 24'-0'' 25'-0'' 26'-0'' 27'-0'' 28'-0'' 29'-0'' 30'-0'' 31'-0''
16 127 / 51 117 / 45
14 166 / 64 152 / 56 140 / 50 130 / 44
12 233 / 89 214 / 78 197 / 69 182 / 62 169 / 55 157 / 49 147 / 44 137 / 40
10 296 / 114 272 / 100 251 / 89 232 / 79 216 / 70 201 / 63 187 / 57 175 / 51 164 / 47
Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.
81/8”
6”
12” Cover
THE ROOF DECK YOU NEED FOR YOUR NEXT PROJECT
For over 50 years, Canam specializes in the fabrication of steel joists, joist girders and steel deck. Our experts will offer construction solutions tailored to your project’s requirements. 1-877-499-6049
www.canam-construction.com
6PRODUCT DATASHEETRoof Deck Type LS7.5
Long Span Deck Type LS7.5Technical Data
Depth 71⁄2”
Rib width 81⁄8”
Fy 40 ksi
Cover width 12”
Product
Options available:CellularCellular/acoustic
Finishes available:Galvanized ASTM A653, G60, G90 and A25Galvanized plus weldable primerShop applied finish paints are available
GageSection properties*
Wt (psf)
Ip (in4)
In (in4)
Sp (in3)
Sn (in3)
16 6.10 15.94 16.08 3.85 4.11
14 7.70 20.04 20.04 5.07 5.11
12 10.70 27.94 27.94 7.10 7.10
10 13.80 35.77 35.77 9.04 9.04
* Ip, In, Sp and Sn are the section properties per foot of width.
GageSingle Span MAX. UNIFORM FACTORED LOAD / Load that produces L/240 deflection
26'-0'' 27'-0'' 28'-0'' 29'-0'' 30'-0'' 31'-0'' 32'-0'' 33'-0'' 34'-0''
16 116 / 59 111 / 53 107 / 48 104 / 43
14 177 / 75 164 / 67 153 / 60 142 / 54 133 / 49 125 / 44 117 / 40
12 249 / 104 231 / 93 215 / 83 201 / 75 188 / 68 176 / 61 165 / 56 155 / 51 146 / 47
10 318 / 133 295 / 119 274 / 107 256 / 96 239 / 87 224 / 79 210 / 71 198 / 65 186 / 60
Notes : - With total uniform factored load limited to 73 psf and total uniform service load limited to 40 psf. - Table based on a 2” of exterior bearing. Greater bearing can increase capacity.
81/8”
7½”
12” Cover
Notes :
CyanC
MagentaM
JauneY
NoirK
PMS PMS PMS PMS PMS PMS PMS
DieD
épreuveinterne
Approbation directeur création :
Coordonnatrice
Révision
Conseillère
N˚ dossier
Épaisseur
Format Bleed
Format final
impression
Approbation révision : Date :
Approbation interne : Approbation client : Date :
Le « trapping » de ce document n’a pas été vérifié a été vérifié
épreuveclient
Le « Codes-barres » du document position seulement sont bons
L’imposition de ce document n’a pas été vérifié a été vérifié
Signer cette épreuve SVP
Client
Description
Nom document
Format doc.
Logiciel
Infographiste
Designer - D.A
Dir. création
Polices
Type de papier
Type de reliure
Type impression
Date
506 McGill, 5e étage,Montréal (Québec), H2Y 2H6
tél. : 866.5521 / 1 866 966.5521 téléc. : 866.3272 / 1 888 896.3272