9
© Riley Power Inc., 2012 www.babcockpower.com The Supercritical Recirculation Boiler by T. F. Walsh Manager Staff Engineering RILEY POWER INC. a Babcock Power Inc. company June 1968 Technical Publication (formerly Riley Stoker Corporation)

Upload: others

Post on 12-Apr-2020

6 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler

© Riley Power Inc., 2012 www.babcockpower.com

The Supercritical Recirculation Boiler

by

T. F. WalshManager

Staff EngineeringRILEY POWER INC.

a Babcock Power Inc. company

June 1968

Technical Publ icat ion

(formerly Riley Stoker Corporation)

Page 2: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler
Page 3: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler
Page 4: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler
Page 5: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler
Page 6: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler
Page 7: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler
Page 8: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler
Page 9: The Supercritical Recirculation Boiler · load. Consequently, the full feed pump power re- quirement of a once-through boiler is considerably greater thon on a recirculation boiler