The ultimate VRF system

Page 2: The ultimate VRF system

TOSHIBA02

EXPERIENCETHE FUTURE

Benefits for consultants Benefits for users Benefits for installers

Universal

Unrivalled Usability

The expectations of a modern air conditioning system have evolved over the past years. Today, advanced comfort goes hand in hand with reduced energy and maintenance costs, combined with maximized simplicity and true operational flexibility. SMMS-u associates all of Toshiba innovative spirit and outstanding expertise to create highly efficient solution with maximum end user comfort at its core.

Beyond superior performance and efficiency

Unparalleled integrated solutions and upgradability

Industry-leading flexibility and connectivity

SMMS-u offers unlimited possibilitiesin terms of capacity, connectivity,indoor unit lineup and control

solutions, providing the correctsolution for your customers needs.

Toshiba’s intuitive selection tool willguide you through the selectionprocess with minimal input from yourside, ensuring trouble-free installation and operation. All SMMS-u systemcome with the Eurovent certification as standard.

There is nothing like a comfortableplace to enjoy the present moment.Full of Toshiba innovations, the newSMMS-u guarantees all year roundcomfort combined with superior

energy management, advanced airfiltration and full control solutions formaximized product usability.

Brand new chassis of SMMS-urealized compact chassis and lightweight. By using benefits of this

brand new chassis and technology, Installer can enjoy shortening work

time by simplified piping work, lessadditional refrigerant necessaryamount and simplified test runsetting. Therefore, Installer is able to get profit greatly from new SMMS-udesign.

Page 3: The ultimate VRF system

TOSHIBA03

TOP CLASS EFFICIENCY

0

2.0

3.0

4.0

5.0

5.104.51 4.23

3.764.62 4.24

3.93 3.963.61

8 10 12 14 14A 16 18 20 22 24 (HP)

EER up to 5.1

5.29 5.02 4.90 4.824.63 4.23 4.26

3.80

COP up to 5.2

4.79

UNIQUE ON THE MARKET: TRIPLE ROTARY COMPRESSOR

Please take a look at this brand new chassis, which is the perfect mix of dimension, efficiency, capacity & sound level. Engineered in Japan, SMMS-u integrates all the latest technological innovations from Toshiba to achieve top class efficiency and ensure unrivalled comfort levels.

The exclusive Toshiba triple rotary compressor brings outstanding performances to SMMS-u without compromise on system reliability.

Utilizing the new highly efficient core technologies results in greater energy efficiency and performances.

Up to 24HP single module / 120HP combination

Simplified maintenance: Easy acces to all internal components

Strong static pressure: Up to 80Pa avaialble

Super-efficient: Full product height heat exchanger

Compact chassis:Only 1,690mm height

14A to 24HP8 to 14HP

Earthquake and typhoonDurability chassis

DLC treatment

Low vibration

Large capacity

Wide operating range

A BRAND NEW CHASSIS

Low required refrigerant

1.0

8 10 12 14 14A 16 18 20 22 24 (HP)

3.29

4.01

6.0(COP)

0

2.0

3.0

4.0

5.0

1.0

6.0(EER)

(Diamond Like Carbon)

Page 4: The ultimate VRF system

TOSHIBA04

FLEXIBLEFREE COMBINATION Unit combination can be arranged to follow

installation site requirement.

SMMS-u oversteps all the limits of VRF for maximized project coverage. Whatever the piping length, the height difference, the number of indoor units connected and operating… SMMS-u is always delivering the best.

3,000 combinations patternsFree combination

1,200m max Long piping length

110m max High piping lift

FLEXIBLECONNECTIVITY

Up to 128 indoor Large FCU connection

Max 200% combinationHigh diversity

Max 120HP by 5 unitsconnectionLarge system capacity

Combinations examples - SMMS-u 44HP total 36 combinations

Total

3000combination

patternis available

Note: Outdoor unit still should align from larger to smaller HP

Standard (Space-saving)

24HP 20HPCapacity Cooling: 123.0 kW Heating: 132.0 kWEfficiency Cooling: 3.56 Heating: 4.13

Wedth: 2,600 mm.

Increased heating capacity

22HP 22HPCapacity Cooling: 123.0 kW Heating: 138.0 kWEfficiency Cooling: 3.61 Heating: 3.80

Wedth: 2,600 mm.

Balance (Space-saving)

24HP 10HP 10HPCapacity Cooling: 123.0 kW Heating: 132.0 kWEfficiency Cooling: 3.75 Heating: 4.43

Wedth: 3,310 mm.

Balance (Moderate)

16HP 16HP 12HPCapacity Cooling: 123.5 kW Heating: 137.5 kWEfficiency Cooling: 4.24 Heating: 4.67

Wedth: 3,610 mm.

Max. Highest efficiency

12HP 8HP 8HP 8HP 8HPCapacity Cooling: 123.1 kW Heating: 137.5 kWEfficiency Cooling: 4.83 Heating: 5.14

Wedth: 5,030 mm.

Balance efficiency

12HP 12HP 10HP 10HPCapacity Cooling: 123.0 kW Heating: 138.0 kWEfficiency Cooling: 4.35 Heating: 4.89

Wedth: 4,020 mm.

Page 5: The ultimate VRF system

TOSHIBA05

EXPANSIONOPERATING TEMPERATURE RANGE

COMFORTABOVE ALL

STRONGADAPTABILITY

SMMS-u integrates new features to adapt operations to local constraints with a constant target: the alliance of comfort and energy savings.

Heat exchanger usage areaautomatically varies dependingon workload, maximizing energysavings and system reliability.

Smart Grid ready withremote or dry contactdemand control function.

Automatic backup incase of combinationssystems failure.

Autobackupfunction

Splitted heat exchanger

X% LOAD

Demand control

No need to prepare oil balancepipe by new lubricationtechnology. Balance oil

circuit free

Smart control to automaticallyequalize compressor operatinghours. Rotation

drive

The refrigerant heat sink can bring downtemperature of electric parts on inverter.By using this new function, SMMS-u canoperate in high ambient condition such as 52°C.

SMMS-u can select optimal heat exchangersize based on operating mode, outdoor tempand capacity load. By using this function, SMMS-u can realize high efficiency notonly full load operation but also part loadoperation.

-25 0 25 50 ( C)

Heatexchanger

Refrigerantheat sink

Part load conditionFull load

15.5°C

-5°C

Heating

CoolingCooling

Heating

52°C52°C

-25°C-25°C

Providing end user high level of comfort is SMMS-u priority.In addition to a wide range of indoor units adapted to any kind of roomconfiguration. Toshiba is offering one of the most accurate refrigerantflow management system.

1290W14A, 16, 18, 20, 22, 24HP

990W8, 10, 12, 14HP

Or

Page 6: The ultimate VRF system

TOSHIBA06

New chassis

WIDEST INDOORUNIT RANGE

1-Way Cassette

Compact chassisSmart operation

Advanced filtration

Smart CassetteHigh performanceSmart operation

2021 NEWindoor units

SMMS-u Indoor units

Model(HP)

(kW)

High performance 4-way CassetteMMU-UP_1H-E

4-way CassetteMMU-UP_1HP-E

Compact 4-way CassetteMMU-UP_1MH-E

2-way CassetteMMU-UP_1WH-E

1-way CassetteMMU-UP_1YHP-E

1-way CassetteMMU-UP_1SH-E

Super Slim DuctMMD-UP_1SPHY-E

Concealed DuctMMD-UP_1BHP-E

HSP Concealed DuctMMD-UP_1HP-E

Fresh Air Intake DuctMMD-UP_1HFP-E

CeilingMMC-UP_1HP-E

High WallMMK-UP_1HP-E

Floor Standing CabinetMML-UP_1H-E

ConsoleMML-UP_1NH-E

Floor StandingMMF-UP_1H-E

18 different indoor unit types.18 capacities from 0.8 to 20HP.Thousands of combinations toperfectly match users expectations.

Floor Standing ConcealedMML-UP_1BH-E

Fresh Air Intake DuctLight and compact chassis

Wide air flow range

Air -to- Air Heat exchanger with DX-coilMMD-VN_2HEX1E

Dx-coil controller & Dx-valve kitTCB-IFD_1E & RBM-A_1VAE

14.012.010.08.06.05.04.03.23.02.52.01.71.251.00.8

40.034.028.022.416.014.011.29.08.07.15.64.53.62.82.2

16.0

45.0

20.0

56.0

18.0

50.4

*1

*1

*1: Because these models can support only old communication protocol, please communicate with local distributor if you want to connect these indoor units.

Page 7: The ultimate VRF system

EASY COMMISSIONINGAND MAINTENANCE

Save time during commissioning and maintenance. Choose between the “Wave Tool Advance” using Smartphone NFC connection or the link adaptor connected to the outdoor or indoor unit.

TOSHIBA07

Simplified, advanced, centralized, touch screen… Toshiba is offering a large choice of control solutions all compatible

BACnet®, LoNWoRKS® and Modbus® BMS languages

WIDE CONTROLLINEUP

BMS-CT2560U-EMax 256 indoor units connected

RBC-AMSU51-ES / ENMax 16 indoor units connected

RBC-ASCU11-E

TOSHIBASELECTION TOOL

Designed for novice and expert users, Toshiba selection software creates simple, yet detailed VRF system schematics. It is highly versatile, allowing the level of detail to be tailored to suit customer requirements. Final detailed reports can be produced and sent to customers in PDF format or in more complex files, such as AutoCAD DXF, allowing simple integration into existing software packages.

* Please contact Toshiba for Android*phone compatibility list.

Wireless connection using smartphone* NFC technology to collect system data

Direct USB connection to get access to system data

Get access to system data indoor using link adaptor

System operation self record using link adaptor

with the new TU2C Link protocol. SMMS-u is also compatible with

RBC-AMTU31-E

NEWApplicationWave Tool Advance

Page 8: The ultimate VRF system

The m

ater

ials a

nd in

form

ation

refe

renc

ed in

this

broc

hure

are p

rovid

ed as

info

rmat

ion on

ly an

d are

not t

o be t

aken

as l

egal

or ot

her p

rofe

ssio

nal a

dvice

– SM

MS-

u – F

ebru

ary 2

021 -

© T

OSHI

BA 2

021

All ri

ghts

rese

rved

. TOS

HIBA

rese

rves

the r

ight to

chan

ge ce

rtain

infor

matio

n and

spec

ifica

tions

conta

ined

in th

is do

cume

nt at

any

time

and

with

out p

rior n

otice

. © P

hoto

s: A

dobe

Sto

ck /T

oshi

ba C

arrie

r Cor

pora

tion.

Ref

.: SM

MS-

u sal

es b

roch

ure

– T20

21-B

03-A

SIA(

50Hz

)

C: cooling mode - H: heating mode

SMMS-u Physical data

Outdoor unit (Anti-Corrosion) MMY-Air flow m 3/hSound power level dB(A)

Sound pressure level dB(A)

level dB(A)

Sound pressure level dB(A)

External static pressure available

Pa

Dimensions (h x w x d) mm

Weight kgCompressor typeRefrigerant charge R410A kg

Gas line type - diameterLiquid line type - diameterFarthest piping equivalent length

m

Farthest piping real length m

Maximum total extension ofpiping length

m

Maximum lift (indoor unit above/below)

m

Operating range - DB °C

Operating range - WB °C

Power supply V-ph-Hz

SMMS-u Performances

Outdoor unit (Anti-Corrosion) MMY-

Cooling capacity kW

Power input kWEER kW/kWRunning current A C

Heating capacity kW

Power input kWCOP kW/kWRunning current H Maximum overcurrent protection

A

C

H

A

C

C

H

H

C

H

Outdoor unit MMY-

Outdoor unit MMY-

Sound power

MUP0801HT8JP MUP1001HT8JP MUP1201HT8JP MUP1401HT8JP MUP1601HT8JP MUP1801HT8JP MUP2001HT8JP MUP2201HT8JP MUP2401HT8JP8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP 24 HP

20 32 32 40 40 50 50 63 80

7.67 10.1 12.2 12.7 16.6 20.3 22.7 27.9 26.45.29 5.02 4.79 4.90 4.63 4.23 4.26 3.80 4.014.73 6.28 7.83 8.17 10.80 13.25 14.78 18.17 17.22

25.0 31.5 37.5 40.0 50.0 56.0 63.0 69.0 69.0

7.12 9.96 12.3 16.5 16.3 19.7 21.7 26.2 31.35.10 4.51 4.23 3.76 4.24 3.93 3.96 3.61 3.294.39 6.21 7.92 10.64 10.61 12.82 14.15 17.04 20.37

22.4 28.0 33.5 40.0 45.0 50.4 56.0 61.5 67.0

9900 10500 11700 11880 15300 16800 15900 16500 16500MUP0801HT8JP MUP1001HT8JP MUP1201HT8JP MUP1401HT8JP MUP1601HT8JP MUP1801HT8JP MUP2001HT8JP MUP2201HT8JP MUP2401HT8JP

75.0 77.0 79.0 79.0 83.0 84.0 86.0 86.0 86.0

53.0 55.0 58.0 58.0 60.0 61.0 63.0 63.0 63.0

76.0 77.0 81.0 82.0 86.0 89.0 90.0 90.0 90.0

56.0 58.0 62.0 62.0 63.0 67.0 67.0 67.0 67.0

80 80 80 80 80 80 80 80 80

1690 x 990 x 780 1690 x 990 x 780 1690 x 990 x 780 1690 x 990 x 780 1690 x 1290 x 780 1690 x 1290 x 780 1690 x 1290 x 780 1690 x 1290 x 780 1690 x 1290 x 780

Hermetic TwinRotary

6.0 6.0 6.0 6.0 9.0 9.0 9.0 9.0 9.0

Brazed - 3/4” Brazed - 7/8” Brazed - 1-1/8” Brazed - 1-1/8” Brazed - 1-1/8” Brazed - 1-1/8” Brazed - 1-1/8” Brazed - 1-3/8”

Brazed - 1/2” Brazed - 1/2” Brazed - 1/2” Brazed - 5/8” Brazed - 5/8” Brazed - 5/8” Brazed - 5/8” Brazed - 3/4” Brazed - 3/4”

210 210 210 210 210 210 210 210 210

190 190 190 190 190 190 190 190 190

500 500 500 500 500 500 500 500 500

40 / 110 40 / 110 40 / 110 40 / 110 40 / 110 40 / 110 40 / 110 40 / 110 40 / 110

-5/52 -5/52 -5/52 -5/52 -5/52 -5/52 -5/52 -5/52 -5/52

-25/15.5 -25/15.5 -25/15.5 -25/15.5 -25/15.5 -25/15.5 -25/15.5 -25/15.5 -25/15.5

400(380/415)-3-50

MUP0801HT8P MUP1001HT8P MUP1201HT8P MUP1401HT8P MUP1601HT8P MUP1801HT8P MUP2001HT8P MUP2201HT8P MUP2401HT8P

MUP0801HT8P MUP1001HT8P MUP1201HT8P MUP1401HT8P MUP1601HT8P MUP1801HT8P MUP2001HT8P MUP2201HT8P MUP2401HT8P

228 228 228 228 312 312 334 356 356Hermetic Twin

RotaryHermetic Twin

RotaryHermetic Triple

RotaryHermetic Triple

RotaryHermetic Triple

RotaryHermetic Twin

RotaryHermetic Twin

RotaryHermetic Twin

Rotary

Brazed - 1-1/8”

400(380/415)-3-50 400(380/415)-3-50 400(380/415)-3-50 400(380/415)-3-50400(380/415)-3-50 400(380/415)-3-50400(380/415)-3-50400(380/415)-3-50

MUP14A1HT8JP14 HP

40

14.54.829.34

45.0

13.44.628.65

40.0

13800MUP14A1HT8JP

81.0

58.0

83.0

62.0

80

1690 x 1290 x 780

9.0

Brazed - 1-1/8”

Brazed - 5/8”

210

190

500

40 / 110

-5/52

-25/15.5

MUP14A1HT8P

MUP14A1HT8P

312Hermetic Triple

Rotary

400(380/415)-3-50

Rated conditions Cooling: Indoor 27 °C Dry Bulb / 19 °C Wet Bulb, Outdoor 35 °C Dry Bulb.Heating: Indoor 20 °C Dry Bulb, Outdoor 7 °C Dry Bulb / 6 °C Wet Bulb.Base on equivalent piping length of 7.5m and piping height difference of 0m.

*1

*1 : Besure to refer to the Engineering Databook for details of these conditions and requirements.