the xevo tq-s micro - waters corporation...500 mrm/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5...
TRANSCRIPT
![Page 1: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/1.jpg)
©2014 Waters Corporation 1
The Xevo® TQ-S micro
Redefining Compact Performance
Sensitivity Beyond Expectation
Gunnar Weibchen
![Page 2: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/2.jpg)
©2014 Waters Corporation 2
The power of Xevo
![Page 3: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/3.jpg)
©2014 Waters Corporation 3
What is Xevo?
Xevo is Engineered Simplicity
Xevo is innovative information rich analysis
Xevo is versatility
Xevo systems are backed by providing the most complete system solutions backed by superior support
Xevo is robust, reliable, accessible high performance
![Page 4: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/4.jpg)
©2014 Waters Corporation 4
Class Leading Performance that can
Fit into any Lab
Xevo TQ MS footprint
Xevo TQ-S micro Compact design reduces lab footprint
![Page 5: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/5.jpg)
©2014 Waters Corporation 5
Sr ion guide
with high quality data
RADAR and PICs
Quantitative workflow updates – Standard Addition – Increased no. compounds
Xevo TQ-S micro Innovative Technologies
![Page 6: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/6.jpg)
©2014 Waters Corporation 6
Increasing Instrument Uptime
Key Analytical Challenges
Reducing Sample Turnaround Time
Easy Method Transfer
Understanding Sample Complexity
![Page 7: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/7.jpg)
©2014 Waters Corporation 7
Increasing Instrument Uptime
![Page 8: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/8.jpg)
©2014 Waters Corporation 8
Increasing Instrument Uptime: StepWave
Robust performance driven by proven Z-spray and StepWave technologies
![Page 9: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/9.jpg)
©2014 Waters Corporation 9
0
20000
40000
60000
80000
100000
120000
0 100 200 300 400 500 600 700 800 900
Pea
k A
rea
Injection number
Mean Peak area = 86,501 Standard Deviation = 2,961 %RSD = 3.42%
+15 % of mean
-15 % of mean
900 injections of verapamil in protein-precipitated plasma
Xevo TQ-S micro Robustness data
![Page 10: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/10.jpg)
©2014 Waters Corporation 10
Xevo TQ-S micro: Sensitivity improvement
UPLC/MRM data for the Xevo TQ-S micro relative to the Xevo TQD
ESI- Teflubenzuron, 379>339
Time10.40 10.60 10.80 11.00 11.20 11.40
%
0
100
10x peak area, 5x S:N
ESI+ Vitamin D3, 401>383
Time11.00 11.20 11.40 11.60 11.80 12.00 12.20 12.40 12.60 12.80
%
0
16x peak area, 4x S:N
Positive ion pesticides compounds 1 pg/µL - 10 pg on column
Time9.40 9.60 9.80 10.00 10.20 10.40 10.60 10.80 11.00 11.20 11.40 11.60 11.80 12.00
%
0
Raven_Positive ion pesticides_DDMW14MAY2014_003 Sm (Mn, 2x2) 20: MRM of 2 Channels ES+ 306.2 > 201.1 (Buprofezin
3.17e6
6x peak area, 5x S:N
ESI+ Buprofezin, 306>201
![Page 11: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/11.jpg)
©2014 Waters Corporation 11
Reducing Sample Turnaround Time
![Page 12: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/12.jpg)
©2014 Waters Corporation 12
Reducing Sample Turnaround Time: Xcelerated Ion Transfer™ (XIT)
The new Xcelerated Ion Transfer electronics, featuring SpaceWire technology, enable rapid data acquisition without performance loss
Increasing MRM acquisition speed but maintaining data quality
![Page 13: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/13.jpg)
©2014 Waters Corporation 13
Xevo TQ-S micro Data quality at high speed - Buprofezin
Dwell and Delay Time %RSD (of 10 acquisitions)
10ms 2.33
5ms 5.08
3ms 2.22
1ms 5.49
50 MRM/s
500 MRM/s
4.1% peak area loss
2.08 e5
2.77 e5
2.80 e5
3.31 e5
10048
10059
9672
9642
![Page 14: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/14.jpg)
©2014 Waters Corporation 14
8.5% peak area loss
Xevo TQ-S micro Data quality at high speed - Metaxuron
Dwell and Delay Time %RSD (of 10 acquisitions)
10ms 4.47
5ms 2.52
3ms 2.77
1ms 6.26
50 MRM/s
500 MRM/s
23185
22705
22527
21226 6.00 e5
4.50 e5
5.31 e5
5.77 e5
![Page 15: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/15.jpg)
©2014 Waters Corporation 15
Easy Method Transfer
![Page 16: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/16.jpg)
©2014 Waters Corporation 16
Easy Method Transfer: Xtended Dynamic Range™ (XDR)
Easier to transfer methods from other instruments with higher or lower sensitivities Accessible sensitivity Up to 6 orders of linear dynamic range Xtended Dynamic Range made possible by updated detector electronics
![Page 17: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/17.jpg)
©2014 Waters Corporation 17 Time
0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20
%
0
Lidocaine injections at 6 orders of dynamic range without detector saturation
6 orders of dynamic range: Lidocaine
1x, 1 ng
1x, 100 pg
10x, 10 pg
82x, 1pg
876x, 100 fg
10,000x, 10 fg
10,000x magnification, 1 fg
![Page 18: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/18.jpg)
©2014 Waters Corporation 18
Understanding Sample Complexity
![Page 19: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/19.jpg)
©2014 Waters Corporation 19
RADAR - Unique simultaneous acquisition of MRM and full scan data
See what you cannot see in MRM alone
Improve method
development
Detect
unexpected contaminants
Characterise background
matrix
Understanding Sample Complexity: RADAR
![Page 20: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/20.jpg)
©2014 Waters Corporation 20
RADAR – Method Development
Phospholipids
All endogenous material
A
B
![Page 21: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/21.jpg)
©2014 Waters Corporation 21
RADAR – Unexpected contaminants
Identify unexpected contaminants
Melamine has been used as an adulterant in baby milk formula
![Page 22: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/22.jpg)
©2014 Waters Corporation 22
Full scan TIC
MRM traces
XIC m/z 212
1
2 3
4
5
6
RADAR – Characterize background matrix
![Page 23: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/23.jpg)
©2014 Waters Corporation 23
PICs – Confidence in identification
Hydromorphone reference spectrum
Hydromorphone acquired PICs spectrum
Product Ion Confirmation scanning (PICs) enables the user to confidently identify a peak and quantify the amount present
![Page 24: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/24.jpg)
©2014 Waters Corporation 24
Benefits of the Xevo TQ family
![Page 25: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/25.jpg)
©2014 Waters Corporation 25
Informatics solutions
QUANPEDIA™
QCMonitor
Trendplot
![Page 26: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/26.jpg)
©2014 Waters Corporation 26
TargetLynx XS Standard Addition
![Page 27: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/27.jpg)
©2014 Waters Corporation 27
Universal Source platform
Chromatographic versatility
Compatibility across the board
ESI APCI ESCi™
APPI APCI
APGC ionKey/MS ASAP
UPC2
Nanoflow ESI
H-Class and I-Class M-Class
![Page 28: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/28.jpg)
©2014 Waters Corporation 28
Xevo TQ Portfolio
Xevo TQD
Xevo TQ-S
Rugged robust and proven
The next step in robust sensitivity
A step up to ultimate sensitivity
Xevo TQ-S micro
![Page 29: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/29.jpg)
©2014 Waters Corporation 29
Xevo TQ-S micro summary
Increasing Instrument Uptime – Robust but sensitive performance from ZSpray and StepWave
Reducing Sample Turnaround Time
– Fast MRM acquisition rates with high quality data from XIT
Easy Method Transfer – Wider dynamic range for maximum performance with XDR
Understanding Sample Complexity
– Use RADAR and PICs technology to combine scan data with quantitative MRM analysis
![Page 30: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo](https://reader035.vdocument.in/reader035/viewer/2022071411/61070119b2340a537c058743/html5/thumbnails/30.jpg)
©2014 Waters Corporation 30
Questions?
2014