the xziex™ atmospheric power point2.pdf · atmospheric water generator $2,495 retail $2,120.75...
TRANSCRIPT
THE XZIEXTHE XZIEX™™INDUSTRIAL / COMMERCIALINDUSTRIAL / COMMERCIAL
ATMOSPHERIC ATMOSPHERIC WATER GENERATOR WATER GENERATOR
SYSTEMSSYSTEMSTechnical SpecificationsTechnical Specifications
The XZIEX Industrial/CommercialThe XZIEX Industrial/CommercialAtmospheric Water GeneratorsAtmospheric Water Generators
This is the technical specifications sheet of the XZIEX water generators.
For product information, please refer to the presentation slides
We have 16 different models ranging in capacity and sizes to fit all your water needs. In addition to producing purified drinking water, all the IWS models can be simultaneously used as a:
•Climate Control System (Air Conditioning)
•Central Air Purifier
•Humidity Level Controller
Retail SalesRetail SalesSell a Xziex™ ELITE
Atmospheric Water Generator $2,495 Retail
$2,120.75 with 15% IBO discountearn up to 30% bonus.
For a Grand Total up to $700.00 for each Generator sold at Retail.
(Must hit monthly qualifier)
Sell a Xziex™ ELITEAtmospheric Water Generator
$2,495 Retail $2,120.75 with 15% IBO discount
earn up to 30% bonus.
For a Grand Total up to $700.00 for each Generator sold at Retail.
(Must hit monthly qualifier)
Water GeneratorsOVERVIEW:
Water Water GeneratorsGeneratorsOVERVIEW:OVERVIEW:
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
An Overview of Our Water Generators:An Overview of Our Water Generators:
Performance based on entering air conditions of 85°F (29°C) and 70% RH.
14,4108.7 x 3.2 x 3.4341 x 127 x 13319012,6803,350XZIEX-150-60
9,6256.3 x 2.4 x 2.6249 x 96 x 1021317,7882,055XZIEX-100-60
8,4006.3 x 2.4 x 2.6249 x 96 x 102946,1321,620XZIEX-75-60
5,4005.6 x 2 x 1.8219 x 81 x 72774,9211,300XZIEX-60-60
7,2505.6 x 2.5 x 2.6219 x 96 x 102634,0881,080XZIEX-50-60
6,0005.6 x 2 x 1.8219 x 80 x 70312,008530XZIEX-25-60
Weight +/- 10%
Dimensions LxWxH (m)
Dimensions LxWxH (in.)
Power
kWh
Liters / Day
Gallons / Day
50/60 Hz Models
Products that only produce water.
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
525,60074 / 528,0008,5006.3 x 2.4 x
2.2249 x 96 x
86403,081813XZIEX-HCUc8040
383,40075 / 536,0005,6004.4 x 2.4 x
1.8173 x 96 x
72322,270599XZIEX-HCUc6030
253,62078 / 494,0004,2503.2 x 1.7 x
1.8127 x 66 x
72231,438380XZIEX-HCUc4020
191,34080 / 684,0004,2503.2 x 1.7 x
1.8127 x 66 x
72201,147303XZIEX-HCUc4016
163,08076 / 653,0003,5002.8 x 1.7 x
1.4 112 x 66 x
5719875231XZIEX-HCUc3012
131,58072 / 552,0002,3003 x 1.5 x 1.6109 x55 x 6217757200XZIEX-HCUb2010
110,88075 / 652,0002,3003 x 1.5 x 1.6109 x 55 x
6215602169XZIEX-HCUb2008
56,88075 / 631,0009002 x 1 x 1.280 x 42 x 44731483XZIEX-HCUb1004
2,174,04061 / 80
36,00015,100
14.1 x 2.4 x 2.6
556 x 96 x 102195
13,1343,470XZIEX-150-50-A
1,435,77059 / 74
21,5009,970
7.9 x 2.4 x 2.6
311 x 96 x 1021348,4412,230XZIEX-100-50-A
1,079,15662 / 83
18,7508,400
6.3 x 2.4 x 2.6
249 x 96 x 102966,4351,700XZIEX-75-50-A
719,43861 / 8312,50
07,2505.6 x 2.4 x
2.6219 x 96 x
102654,2961,135XZIEX-50-50-A
359,71960 / 836,2504,0004.8 x 2 x 1.8188 x 80 x
70322,120560XZIEX-25-50-A
Total Btuh
LAT (°F)(gr
/lb)
A/C Air
(SCFM)
Weight +/- 10%
Dimensions LxWxH
(m)
Dimensions LxWxH
(in.)
Power kWh
Liters /
Day
Gallons / Day
50/60 Hz Models
Products that produce water and supply cool, dry air.
An Overview of Our Water Generators:An Overview of Our Water Generators:
XZIEXXZIEX‐‐25 50/60 Hz 25 50/60 Hz With A/CWith A/C Technical SpecificationsTechnical Specifications
560 gallons / 2,120 liters of water per‐day or 204,400 gallons / 773,800 liters per‐year
Energy consumption 32 kilowatts per hour (kWh) at 85°F and 70% RH H x W x L = 70 in/1.8 m x 80 in/2 m x 188 in/4.8m
& Weights 6,000 lbs./2,722 kgs.
Moisture removal rate of 196 lbs/hr at 85°F and 70% RHUtilities: 208 or 230 Volts, Single or Three Phase 50/60 Hz
Cost of water/gallon = 1.37 x electric cost per kWh
Conditioned Air = 6,250 SCFM
Uses 25 tons of compressor cooling
Total BTU = 359,719
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEXXZIEX‐‐25 50/60 Hz 25 50/60 Hz Without A/CWithout A/C Technical SpecificationsTechnical Specifications
530 gallons / 2,006 liters of water per‐day or 193,450 gallons / 732,190 liters per‐year
Energy consumption 32 kilowatts per hour (kWh) at 85°F and 70% RH H x W x L = 70 in/1.8 m x 80 in/2 m x 219 in/5.6m
& Weights 6,000 lbs./2,722 kgs.
Moisture removal rate of 196 lbs/hr at 85°F and 70% RHUtilities: 208 or 230 Volts, Single or Three Phase 50/60 Hz
Cost of water/gallon = 1.37 x electric cost per kWh
Conditioned Air = 6,250 SCFM
Uses 25 tons of compressor cooling
Total BTU = 359,719
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEXXZIEX‐‐50 50/60 Hz 50 50/60 Hz With A/CWith A/C Technical SpecificationsTechnical Specifications
1,135 gallons / 4,296 liters of water per‐day or 414,275 gallons / 1,568,040 liters per‐year
Energy consumption 65 kilowatts per hour (kWh) at 85°F and 70% RH H x W x L = 102 in/2.6 m x 96 in/2.4 m x 219 in/5.6m
& Weights 9,600 lbs./4,355 kgs.
Moisture removal rate of 397.25 lbs/hr at 85°F and 70% RHUtilities: 460/208 or 230 Volts, 50/60 Hz Three Phase
Cost of water/gallon = 1.37 x electric cost per kWh
Conditioned Air = 12,500 SCFM
Uses 50 tons of compressor cooling
Total BTU = 719,438
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEXXZIEX‐‐50 50/60 Hz 50 50/60 Hz Without A/CWithout A/C Technical SpecificationsTechnical Specifications
1,080 gallons / 4,088 liters of water per‐day or 394,200 gallons / 1,492,120 liters per‐year
Energy consumption 63 kilowatts per hour (kWh) at 85°F and 70% RH H x W x L = 102 in/2.6 m x 96 in/2.4 m x 219 in/5.6m
& Weights 9,600 lbs./4,355 kgs.
Moisture removal rate of 378 lbs/hr at 85°F and 70% RHUtilities: 460/208 or 230 Volts, 50/60 Hz Three Phase
Cost of water/gallon = 1.40 x electric cost per kWh
Conditioned Air = 12,500 SCFM
Uses 50 tons of compressor cooling
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEXXZIEX‐‐75 50/60 Hz 75 50/60 Hz With A/CWith A/C Technical SpecificationsTechnical Specifications
1,700 gallons/6,435 liters of water per‐day or 620,500 gallons/2,348,775 liters per‐year
Energy consumption 96 kilowatt/hour (kWh) at 85°F and 70% RHH x W x L = 102 in/2.6m x 96 in/2.4m x 249 in/6.3 m & Weights 9,600 lbs/4,355 kgs
Supply Fan: Centrifugal with variable speed control
Utilities: 460/208 or 230 Volts, 50/60Hz Three Phase
Cost of water/gallon = 1.36 x electric cost per kWh
Moisture removal rate of 595 lbs/hr at 85°F and 70% RHConditioned Air = 18,750 SCFM
Uses 75 tons of compressor cooling
Total BTU = 1,079,156
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEXXZIEX‐‐75 50/60 Hz 75 50/60 Hz Without A/CWithout A/C Technical SpecificationsTechnical Specifications
1,620 gallons/6,132 liters of water per‐day or 591,300 gallons/2,238,180 liters per‐year
Energy consumption 94 kilowatt/hour (kWh) at 85°F and 70% RHH x W x L = 102 in/2.6m x 96 in/2.4m x 249 in/6.3m & Weights 9,600 lbs/4,355 kgs
Supply Fan: Centrifugal w. variable speed control
Utilities: 460/208 or 230 Volts, 50/60 Hz Three Phase
Cost of water/gallon = 1.39 x electric cost per kWh
Moisture removal rate of 567 lbs/hr at 85°F and 70% RHConditioned Air = 18,750 SCFM
Uses 75 tons of compressor cooling
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEXXZIEX‐‐100 50 Hz 100 50 Hz With A/CWith A/C Technical SpecificationsTechnical Specifications
2,230 gallons/8,441 liters of water per‐day or 813,950 gallons/3,080,965 liters per‐year
Energy consumption 134 kilowatts per hour (kWh) at 85°F and 70% RHH x W x L = 102 in/2.6m x 96 in/2.4m x 280 in/7.1m & Weights 9,300 lbs/4218 kgs
Moisture removal rate of 780.5 lbs/hr at 85°F and 70% RHUtilities: 460/208 or 230 Volts, 50 Hz, Three Phase
Cost of water/gallon = 1.44 x electric cost per kWh
Conditioned Air = 21,500 SCFM
Uses 100 tons of compressor cooling
Total BTU = 1,435,770
XZIEXXZIEX‐‐100 50/60 Hz 100 50/60 Hz Without A/CWithout A/C Technical SpecificationsTechnical Specifications
2,055 gallons/7,778 liters of water per‐day or 750,075 gallons/2,838,970 liters per‐year
Energy consumption 131 kilowatts per hour (kWh) at 85°F and 70% RHH x W x L = 102 in/2.6m x 96 in/2.4m x 249 in/7.1m & Weights 9,300 lbs/4218 kgs
Moisture removal rate of 719.25 lbs/hr at 85°F and 70% RHUtilities: 460/208 or 230 Volts, 50/60 Hz, Three Phase
Cost of water/gallon = 1.53 x electric cost per kWh
Conditioned Air = 21,500 SCFM
Uses 100 tons of compressor cooling
Total BTU = 1,435,770
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEX‐25 50/60 Hz Without A/C Technical Specifications
XZIEXXZIEX‐‐150 50/60 Hz 150 50/60 Hz With A/CWith A/C Technical SpecificationsTechnical Specifications
3,470 gallons/13,134 liters of water per‐day or 1,266,550 gallons/4,793,910 liters per‐year
Energy consumption 195 kilowatts per hour (kWh) at 85°F and 70% RHH x W x L = 133 in/3.4m x 127 in/3.2m x 403 in/10.2 m & Weights 9,300 lbs/4,218 kgs
Moisture removal rate of 1,214.50 lbs/hr at 85°F and 70% RHUtilities: 460/208 or 230 Volts, 50/60 Hz Three Phase
Cost of water/gallon = 1.35 x electricity cost per kWh
Conditioned Air = 39,750 SCFM
Uses 150 tons of compressor cooling
Total BTU = 2,174,040
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEX‐25 50/60 Hz Without A/C Technical Specifications
XZIEXXZIEX‐‐100 50/60 Hz 100 50/60 Hz Without A/CWithout A/C Technical SpecificationsTechnical Specifications
3,350 gallons/12,680 liters of water per‐day or 1,222,750 gallons/4,628,200 liters per‐year
Energy consumption 190 kilowatts per hour (kWh) at 85°F and 70% RHH x W x L = 133 in/3.4m x 127 in/3.2m x 403 & Weights 9,300 lbs/4,218 kgs
Moisture removal rate of 1,172.50 lbs/hr at 85°F and 70% RHUtilities: 460/208 or 230 Volts, 50/60 Hz Three Phase
Cost of water/gallon = 1.36 x electricity cost per kWh
Conditioned Air = 39,750 SCFM
Uses 150 tons of compressor cooling
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
@ 60Hz = 83 gallons/313 liters of water per‐day or 30,295 gallons/114,515 liters/yr@ 50Hz = 69 gallons/261 liters of water per‐day or 25,185 gallons/95.200 liters/yrEnergy consumption 7 kilowatts per hour (kWh) at 85°F and 70% RHH x W x L = 44 in/1m x 50 in/1.2m x 99 in/2.3m & Weights 900 lbs/408 kgsMoisture removal rate of 29.05 lbs/hr at 85°F and 70% RHUtilities: 208 or 230 Volts, Single or Three Phase 50 HzCost of water/gallon = 1.47 x electric cost per kWhConditioned Air = 1000 SCFM@ 60Hz = 4 tons of refrigeration/@ 50Hz = 3 tons of refrigerationTotal BTU = 56,880Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only)
HCU‐1004 60/50 Hz Technical Specifications
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
XZIEXXZIEX‐‐HCU 2008 60/50 Hz Technical SpecificationsHCU 2008 60/50 Hz Technical Specifications@ 60 Hz =169 gallons/641 liters of water per‐day or 61,685 gallons/233,965
liters per‐yr@ 50 Hz = 133 gallons/503 liters per‐day or 48,545 gallons/183,500 liters per‐yrEnergy consumption 15 kilowatts/hour (kWh) at 85°F and 70%RHH x W x L = 54 in/1.4m x 60 in/1.5m x 118 in/3m & Weights 1,550 lbs/703 kgsSupply Fan: Centrifugal w. variable speed controlsUtilities: 230 Volts, Three Phase 50/60 HzCost of water per‐gallon = 1.69 x cost of electricity per KwHMoisture removal rate of 55.65 lbs/hr at 85°F and 70%RHConditioned Air = 2000 SCFM@ 60 Hz = 8 tons of refrigeration/@ 50 Hz = 7 tons of refrigerationTotal BTU = 110,880Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only)
XZIEX HCUXZIEX HCU‐‐3012 60/50 Hz Technical Specifications3012 60/50 Hz Technical Specifications@ 60 Hz =231 gallons/873 liters of water per‐day or 84,315 gallons/318,711 liters per‐yr@ 50 Hz = 193 gallons/730 liters of water per‐day or 70,445 gallons/266,282 liters per‐yrEnergy consumption 19 kilowatts/hour (kWh) at 85°F and 70%RHH x W x L = 54 in/1.4m x 60 in/1.5m x 118 in/3m & Weights 1,500 lbs/680 kgsSupply Fan: Centrifugal w. variable speed controlsUtilities: 230 Volts, Three Phase 50/60 HzCost of water per‐gallon = 1.63 x cost of electricity per KwHMoisture removal rate of 55.65 lbs/hr at 85°F and 70%RHConditioned Air = 3000 SCFM@ 60 Hz = 12 tons of refrigeration/@ 50 Hz = 10 tons of refrigerationTotal Btuh = 163,080Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only)
Please do not hesitate to contact us for more details on the specifications
The HCU models utilize Desiccant Wheel
@ 60 Hz = 303 gallons/1,145 liters per‐day or 110,595 gallons/418,049 liters per‐year@ 50 Hz = 253 gallons/956.34 liters per‐day or 92,345 gallons/ 349,064 liters per‐yearEnergy consumption 20 kilowatts/ hour (kWh) at 85°F and 70% RHH x W x L = 70 in/1.8m x 66 in/1.7m x 127 in/3.2 m & Weights 4,250 lbs/1,928 kgsSupply Fan: Centrifugal with variable speed control Utilities: 460/208 or 230 Volts, Three Phase 50/60 HzCost of water/gallon = 1.57 x electric cost per kWhMoisture removal rate of 106.50 lbs/hr at 85°F and 70% RHConditioned Air = 4000 SCFM@ 60 Hz = 16 tons of refrigeration/ @ 50 Hz = 13 tons of refrigerationTotal BTU = 191,340Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only)
XZIEX HCUXZIEX HCU‐‐4016 50/60 Hz Technical Specifications4016 50/60 Hz Technical Specifications
@ 60 Hz = 599 gallons/2,264 liters per‐day or 218,635 gallons/826,440 liters per‐year@ 50 Hz = 499 gallons/1,886 liters per‐day or 182,135 gallons/688,470 liters per‐yearEnergy consumption 32 kilowatts per hour (kWh) at 85°F and 70% RHH x W x L = 70 in/1.8m x 66 in/1.7m x 127 in/3.2 m & Weights 4,850 lbs/2,200 kgsMoisture removal rate of 209.65 lbs/hr at 85°F and 70% RHUtilities: 220 Volts, Single or Three Phase 50/60 HzCost of water/gallon = 1.65 x electric cost per kWhConditioned Air = 6000 SCFM@ 60 Hz = 30 tons of refrigeration/ @ 50 Hz = 25 tons of refrigerationTotal BTU = 383,400 Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (in the United States only)
XZIEX HCUXZIEX HCU‐‐6030 50/60 Hz Technical Specifications6030 50/60 Hz Technical Specifications
@ 60 Hz = 813 gallons/3,073 liters per‐day or 296,745 gallons/1,121,696 liters per‐year@ 50 Hz = 678 gallons/2,563 liters per‐day or 247,470 gallons/935,437 liters per‐yearEnergy consumption: 40 kilowatts per hour (kWh) at 85°F and 70% RHH x W x L = 86 in/2.2m x 81 in/2m x 187 in/4.5m & Weights 5,850 lbs/2,654 kgsMoisture removal rate is 284.55 lbs/hr at 85°F and 70% RHUtilities: 460/208 or 230 Volts, 50/60 Hz Three PhaseCost of water/gallon = 1.18 x electric cost per kWhConditioned Air = 8000 SCFM@ 60 Hz = 40 tons of refrigeration/ @ 50 Hz = 33 tons of refrigerationTotal BTU = 525,600Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only)
XZIEX HCUXZIEX HCU‐‐8040 50/60 Hz Technical Specifications8040 50/60 Hz Technical Specifications
1. Recirculation and delivery pump ‐ constantly re‐circulates water in storage tank and delivers water to point of use (POU). Has built‐in controls that protect pump from running in zero‐flow condition
2. Sediment filter ‐ five micron string wound filter the removes suspended solids from water
3. Carbon filter ‐ removes organics and oxidants from the water
4. Pressure gauges ‐ show the inlet and outlet pressures of the filter cartridges. Change the filters when there is a 10 psi increase in the difference between these two gauges.
5. Germicidal Ultraviolet Unit.‐ the UV chamber allows filtered water to be exposed to high levels of ultraviolet (UV) light. UV treatment disinfects water and prevents buildup of bacteria.
6. Ozone injection.‐ ozone gas is drawn into the tank recirculation stream. Ozone is a very strong oxidant and provides a residual disinfectant that keeps water in the tank free of any biologicalgrowth
STANDARD FILTRATION SYSTEM Technical SpecificationsSTANDARD FILTRATION SYSTEM Technical Specifications
ATMOSPHERIC WATER GENERATORSATMOSPHERIC WATER GENERATORS
ON THE CUTTING EDGE OF A WATER REVOLUTIONON THE CUTTING EDGE OF A WATER REVOLUTION
Thank you!