Thermal Development of Internal Flows. P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi. Concept for Precise Design ……. Development of Flow. Temperature Profile in Internal Flow. Hot Wall & Cold Fluid. q’’. T s (x). T i. T(x). Cold Wall & Hot Fluid. q’’. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Thermal Development of Internal Flows

Thermal Development of Internal Flows

P M V Subbarao

Associate Professor

Mechanical Engineering Department

IIT Delhi

Concept for Precise Design ……

Page 2: Thermal Development of Internal Flows

Development of Flow

Page 3: Thermal Development of Internal Flows

q’’

Ti

Ts(x)

Ti Ts(x)q’’

Hot Wall & Cold Fluid

Cold Wall & Hot Fluid

Temperature Profile in Internal Flow

T(x)

T(x)

• The local heat transfer rate is: xTTAhq mwallxx

Page 4: Thermal Development of Internal Flows

We also often define a Nusselt number as:

fluid

mwall

x

fluid

xD k

DxTTA

q

k

DhxNu

)(

Page 5: Thermal Development of Internal Flows

Mean Velocity and Bulk Temperature

Two important parameters in internal forced convection are the mean flow velocity u and the bulk or mixed mean fluid temperature Tm(z).

The mass flow rate is defined as:

while the bulk or mixed mean temperature is defined as:

p

A

cp

m Cm

TdAuC

xT c

)(

cA

cc

m uTdAAu

xT1

)(

For Incompressible Flows:

Page 6: Thermal Development of Internal Flows

Mean Temperature (Tm)

• We characterise the fluid temperature by using the mean temperature of the fluid at a given cross-section.

• Heat addition to the fluid leads to increase in mean temperature and vice versa.

• For the existence of convection heat transfer, the mean temperature of the fluid should monotonically vary.

Page 7: Thermal Development of Internal Flows

First Law for A CV : SSSF

Tm,in Tm,exit

dx

qz

inmexitmmeanpz TTCmq ,,,

No work transfer, change in kinetic and potential energies are negligible

CVexit

exitin

inCV WgzVhmgzVhmq

22

exitexitininCV hmhmq~~

inexitz hhmq~~

Page 8: Thermal Development of Internal Flows

THERMALLY FULLY DEVELOPED FLOW

• There should be heat transfer from wall to fluid or vice versa.

• Then What does fully developed flow signify in Thermal view?

0,,, inmexitmmeanpz TTCmq

0 xTTAhq mwallxz

Page 9: Thermal Development of Internal Flows

FULLY DEVELOPED CONDITIONS (THERMALLY)

(what does this signify?)

Use a dimensionless temperature difference to characterise the profile, i.e. use

)()(

),()(

xTxT

xrTxT

ms

s

This ratio is independent of x in the fully developed region, i.e.

0)()(

),()(

,

tfdms

s

xTxT

xrTxTx

Page 10: Thermal Development of Internal Flows

0

)()(),()(

),()()()(

x

xTxTxrTxT

x

xrTxTxTxT ms

ss

ms

0

)()(),()(

),()()()(

x

xTxTxrTxT

x

xrTxTxTxT ms

ss

ms

0)()(

),()(),()(

)()(

x

xT

x

xTxrTxT

x

xrT

x

xTxTxT ms

ss

ms

0),()()(

)()(),(

)(,)(

xrTxTx

xTxTxT

x

xrTxTxrT

x

xTs

mmsm

s

Page 11: Thermal Development of Internal Flows

Uniform Wall Heat flux : Fully Developed Region 

tfd

mtfd dx

dT

x

xrT,,

,

  Temp. profile shape is unchanging.

)()(constant'' xTxThq msx

x

xT

x

xT ms

)()(

0),()()(

)()(),(

)(,)(

xrTxTx

xTxTxT

x

xrTxTxrT

x

xTs

mmsm

s

0),()()(

)()(),(

xrTxTx

xTxTxT

x

xrTms

mms

0)()()(),(

xTxTx

xT

x

xrTms

m

Page 12: Thermal Development of Internal Flows

dx

cm

Ph

TT

TTd

pms

ms

Integrating from x=0 (Tm = T m,i) to x = L (Tm = Tm,o):

dx

cm

Ph

TT

TTd L

pms

ms

T

T

om

im

0

,

,

Constant Surface Heat Flux : Heating of Fluid

Page 13: Thermal Development of Internal Flows

Temperature Profile in Fully Developed Region

 

Uniform Wall Temperature (UWT)  

)(0 xdx

dTs

tfdm

ms

stfd dx

dT

TT

TT

x

T,, )(

)(

axial temp. gradient is not independent of r and shape of temperature profile is changing.

Page 14: Thermal Development of Internal Flows

The shape of the temperature profile is changing, but the relative shape is unchanged (for UWT conditions).

Both the shape and the relative shape are independent of x for UWF conditions.

At the tube surface:

)( ][

but

)(

"

00"

0

0

xfTTk

q

r

Tk

y

Tkq

xfTT

r

T

TT

TTr

ms

s

rrys

ms

rr

rrms

s

)(xfkh

Page 15: Thermal Development of Internal Flows

i.e. the Nusselt number is independent of x in the thermally fully developed region.

Assuming const. fluid properties:-

tfdxxxfh,

)(

This is the real significance of thermally fully developed

Page 16: Thermal Development of Internal Flows

Evolution of Macro Flow Parameters

Page 17: Thermal Development of Internal Flows

Thermal Considerations – Internal FlowT fluid Tsurface

a thermal boundary layer develops

The growth of th depends on whether the flow is laminar or turbulent

Extent of Thermal Entrance Region:

Laminar Flow: PrRe05.0 ,

D

x tfd

Turbulent Flow:

10 ,

D

x tfd

Page 18: Thermal Development of Internal Flows

Energy Balance : Heating or Cooling of fluid

• Rate of energy inflow

Tm Tm + dTm

dx

QmpTcm

• Rate of energy outflow mmp dTTcm

Rate of heatflow through wall:

ms TTdAhQ Conservation of energy:

mpmmpms TcmdTTcmTTdAhQ

Page 19: Thermal Development of Internal Flows

mpms dTcmTTdxPh

msp

m TTcm

Ph

dx

dT

This expression is an extremely useful result, from which axialVariation of Tm may be determined.The solution to above equation depends on the surface thermal

condition.

Two special cases of interest are:

1. Constant surface heat flux.2. Constant surface temperature

Page 20: Thermal Development of Internal Flows

Constant Surface Heat flux heating or cooling

• For constant surface heat flux:

imomps TTcmLPqQ ,,''

For entire pipe:

For small control volume:

mps dTcmqdxPh ''

)(''

xfcm

Pq

dx

dT

p

sm

Page 21: Thermal Development of Internal Flows

Integrating form x = 0

xcm

PqTxT

p

simm

''

,)(

The mean temperature varies linearly with x along the tube.

mpms dTcmTTdxPh

For a small control volume:

dx

dT

Ph

cmTT mp

ms

The mean temperature variation depends on variation of h.

Page 22: Thermal Development of Internal Flows

dx

cm

Ph

TT

TTd

pms

ms

Integrating from x=0 (Tm = T m,i) to x = L (Tm = Tm,o):

dx

cm

Ph

TT

TTd L

pms

ms

T

T

om

im

0

,

,

Constant Surface Heat Flux : Heating of Fluid

Page 23: Thermal Development of Internal Flows

mpms dTcmTTdxPh

dxcm

Ph

TT

dT

pms

m

dx

cm

Ph

TT

TTd

pms

ms

Integrating from x=0 (Tm = T m,i) to x = L (Tm = Tm,o):

dx

cm

Ph

TT

TTd L

pms

ms

T

T

om

im

0

,

,

For a small control volume:

Constant Surface Heat flux heating or cooling

Page 24: Thermal Development of Internal Flows

pims

oms

cm

LPh

TT

TT

,

,ln

p

surface

ims

oms

cm

Ah

TT

TT

,

,ln

ims

oms

surface

p

TT

TT

A

cmh

,

,ln

h : Average Convective heat transfer coefficient.

Page 25: Thermal Development of Internal Flows

The above result illustrates the exponential behavior of the bulk fluid for constant wall temperature.

It may also be written as:

to get the local variation in bulk temperature.

It important to relate the wall temperature, the inlet and exit temperatures, and the heat transfer in one single expression.

p

surfaceavg

ims

oms

cm

Ah

TT

TT

exp

,

,

p

avg

ims

ms

cm

xPh

TT

xTT

exp,

Page 26: Thermal Development of Internal Flows

Constant Surface Heat flux heating or cooling

mT

sT

T

x

mT

sT

T

x

is TT if is TT if

Page 27: Thermal Development of Internal Flows

To get this we write:

iopimsomspimomp TTcmTTTTcmTTcmQ

,,,,

Page 28: Thermal Development of Internal Flows

which is the Log Mean Temperature Difference.

The above expression requires knowledge of the exit temperature, which is only known if the heat transfer rate is known.

An alternate equation can be derived which eliminates the outlet temperature.We Know

Page 29: Thermal Development of Internal Flows

Thermal Resistance:

Page 30: Thermal Development of Internal Flows

Dimensionless Parameters for Convection

Forced Convection Flow Inside a Circular Tube

All properties at fluid bulk mean temperature (arithmetic mean of inlet and outlet temperature).

Page 31: Thermal Development of Internal Flows

Internal Flow Heat Transfer

• Convection correlations– Laminar flow– Turbulent flow

• Other topics– Non-circular flow channels– Concentric tube annulus

Page 32: Thermal Development of Internal Flows

Convection correlations: laminar flow in circular tubes

• 1. The fully developed regionfrom the energy equation,we can obtain the exact solution. for constant surface heat fluid

36.4k

hDNuD

Cqs

66.3k

hDNuD

for constant surface temperature

Note: the thermal conductivity k should be evaluated at average Tm

Page 33: Thermal Development of Internal Flows

Convection correlations: laminar flow in circular tubes

• The entry region : for the constant surface temperature condition

3/2

PrReL

D04.01

PrReL

D0.0668

3.66

D

D

DNu

thermal entry length

Page 34: Thermal Development of Internal Flows

Convection correlations: laminar flow in circular tubes

for the combined entry length

14.03/1

/

PrRe86.1

s

DD DL

Nu

2/)/Pr/(Re 14.03/1 sD DL

All fluid properties evaluated at the mean T

2/,, omimm TTT

CTs

700,16Pr48.0

75.9/0044.0 s

Valid for

Page 35: Thermal Development of Internal Flows
Page 36: Thermal Development of Internal Flows

Thermally developing, hydrodynamically developed laminar flow (Re < 2300)

Constant wall temperature:

Constant wall heat flux:

Page 37: Thermal Development of Internal Flows

Simultaneously developing laminar flow (Re < 2300)

Constant wall temperature:

Constant wall heat flux:

which is valid over the range 0.7 < Pr < 7 or if Re Pr D/L < 33 also for Pr > 7.

Page 38: Thermal Development of Internal Flows

Convection correlations: turbulent flow in circular tubes

• A lot of empirical correlations are available.

• For smooth tubes and fully developed flow.

heatingFor PrRe023.0 4.05/4DDNu

coolingfor PrRe023.0 3.05/4DDNu

)1(Pr)8/(7.121

Pr)1000)(Re8/(3/22/1

f

fNu D

d

•For rough tubes, coefficient increases with wall roughness. For fully developed flows

Page 39: Thermal Development of Internal Flows

Fully developed turbulent and transition flow (Re > 2300)

Constant wall Temperature:

Where

Constant wall temperature: For fluids with Pr > 0.7 correlation for constant wall heat flux can be used with negligible error.

Page 40: Thermal Development of Internal Flows

Effects of property variation with temperature

Liquids, laminar and turbulent flow:

Subscript w: at wall temperature, without subscript: at mean fluid temperature

Gases, laminar flow Nu = Nu0

Gases, turbulent flow

Page 41: Thermal Development of Internal Flows

Noncircular Tubes: Correlations

For noncircular cross-sections, define an effective diameter, known as the hydraulic diameter:

Use the correlations for circular cross-sections.

Page 42: Thermal Development of Internal Flows
Page 43: Thermal Development of Internal Flows

Selecting the right correlation

• Calculate Re and check the flow regime (laminar or turbulent)• Calculate hydrodynamic entrance length (xfd,h or Lhe) to see

whether the flow is hydrodynamically fully developed. (fully developed flow vs. developing)

• Calculate thermal entrance length (xfd,t or Lte) to determine whether the flow is thermally fully developed.

• We need to find average heat transfer coefficient to use in U calculation in place of hi or ho.

• Average Nusselt number can be obtained from an appropriate correlation.

• Nu = f(Re, Pr)• We need to determine some properties and plug them into the

correlation. • These properties are generally either evaluated at mean (bulk)

fluid temperature or at wall temperature. Each correlation should also specify this.

Page 44: Thermal Development of Internal Flows

Heat transfer enhancement

• Enhancement

• Increase the convection coefficient

Introduce surface roughness to enhance turbulence.

Induce swirl.

• Increase the convection surface area

Longitudinal fins, spiral fins or ribs.

Page 45: Thermal Development of Internal Flows

Heat transfer enhancement

• Helically coiled tube

• Without inducing turbulence or additional heat transfer surface area.

• Secondary flow