Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4. ACCESSORIES 5. MAINTENANCE AND CLEANING & FAULTY RUNNING 6. WARRANTY CAUTION-Before attempting to operate the unit, read this instruction manual carefully CAUTION-HIGH TEMPERATURE "Don't touch the block while it is in operation and until the temperature of the block goes down after turning it off" 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 [email protected] MRC. 9.18

Upload: others

Post on 23-Jun-2020

25 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

Operatin

g M

an

ual

Operatin

g M

an

ual Thermo bath & cool block

DBD-H SERIES

Operating Manual Operating Manual

1. PRODUCTS DESCRIPTION2. USER CONSIDERATION3. USER OPERATION4. ACCESSORIES5. MAINTENANCE AND CLEANING & FAULTY RUNNING6. WARRANTY

CAUTION-Before attempting to operate the unit,

read this instruction manual carefully

CAUTION-HIGH TEMPERATURE

"Don't touch the block while it is in operation and

until the temperature of the block goes down after

turning it off"

3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529

[email protected]

MRC. 9.18

Page 2: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

Difference of bath

P.I.D temperature controller

- Easy to control and check setting temp.

MRC Blocks are much thicker than others

- Prevent current temp. from sudden down when a tube is put into a tube hole. Do not need put water or mineral oil into the gab between

hole and tube. The shape of hole is same with tubes.

Temperature Calibration

- Able to calibrate the different temperature between setting and current temp. Safe device.

A. Electrical fuse

B. If current temp, does not reach the setting temp, for 99hour 59min

ALM Lamp on temperature controller would be blink.

C. This books are used in up to 150˚(DBD-H1,DBD-H2,DBD-H4),

95˚ (DBD-C1). If the current temp. is over 150.5˚(DBD-H1,

DBD-H2,DBD-H4), 95.5˚(DBD-C1). ALM lamp would be blink

D. If the current temp, keep over 150˚C continually, the heater would be turned out automatically.

1

PR

OD

UC

T D

ES

CR

IPT

ION

Introduction

HEAT BLOCK

- One block- Ambient +5 ~150˚C- Dimension - external : W205XD263XH163

DBD-H1

DBD-6400- One block- 0 ~120˚C- Dimension - external : W215XD327XH215

COOL BLOCK

- Two block- Ambient +5 ~150˚C- Dimension - external : W205XD360XH163

DBD-H2

- Four block- Ambient +5 ~150˚C- Dimension - external : W335XD360XH163

DBD-H4

Page 3: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

Description

AC100 - 240V(*220 - 230V : CE cert)

50/60Hz

Ambient +5˚C ~ 150˚C

Model

Temp. Range

Temp. Accuracy

Temp. Timer

Wattage

Power

DBD-H1 DBD-H2

±0.2˚C

99hour 59min

Heating method

Cooling method

DBD-H4

310W 610W 1200W

Frequency

BACK SIDE

MAIN BODY

TEMPERATURE CONTROLLER

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

Current temperature

Setting temperature

MODE key

UP keyDOWN keyMOVE key

RUN/STOP key

RUN Lamp(orange)TIME Lamp(green)

HEAT Lamp(red)ALARM Lamp(red)

Specification

PR

OD

UC

T D

ES

CR

IPT

ION

2

Dimensions(mm)

Weight

Capacity 1 Block2 Block1 Block

11.5kg (without block)6kg (without block)3kg (without block)

W205 x D360 x H163 W335 x D360 x H163W205 x D260 x H163

MaterialEnergy plate an sample block : Aluminuminside and insulating side : Stainless steel

Cartridge heater

- Peltier

0˚C ~ 120˚C

Receptacle Specification

Voltage / Hz

Serial Number

RUN ●TIME ●

HEAT ●ALM ●

PV

SV

˚C

RUNSTOP MODE

Power switch

Inner chamber

Ventilation hole

Bottom foot

Temperaturecontroller

DBD-C1

4 Block

10kg (without block)

W215 x D327 x H215

360W

Page 4: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

V011

110V

220V

Place the unit on a stable, flat and cleansurface and check if the four rubber legs are touched firmly on the surface.

Check if the voltage indicated on appliance corresponds to the local mains voltage before you connect the appliance.

Unplug the appliance : - If problems occur during the heating and rotating process.- Before you start cleaning the unit.- Never use the appliance if the plug, the cord or the appliance it self is damaged

Do not place this instruments beside sunnyplace or heater. If the main body is higherthan room temperature, It could affects theinside setting temperature.

Be careful not to drop any chemical liquid or water into the hole for blocks, because it could be reason of causing unstable setting temperature.

User consideration

US

ER

CO

NS

IDE

RA

TIO

N

Environmental conditions- Indoor use.- Environment temperature 5˚C to 40˚C.- Maximum relative humidity 80% for temperatures up to 31˚C decreasing linearly to 50% relative humidity at 40˚C.- Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage.- Other supply voltage fluctuations as stated by the manufacturer. - Transient overvoltages according to installation categories.- Installation category : CATⅡ - Pollution degree 2- IPXO (ordinary)

3

Power switch is in the "on" position and operate it after 3 seconds for stable using of product.

RUN ●TIME ●

HEAT ●ALM ●

PV

SV

˚C

RUNSTOP MODE

RUN ●TIME ●

HEAT ●ALM ●

PV

SV

˚C

RUNSTOP MODE

During use this instrument, Please do not touch the block. Hand could be burnt.

RUN ●TIME ●

HEAT ●ALM ●

PV

SV

˚C

RUNMODE

Do not need put water or mineral oil into the gab between holes and tubes. Because the shape ofhole and tube is same.* Never use PEG withthis instrument, PEG could peel off the paint of main body.

RUN ●TIME ●

HEAT ●ALM ●

PV

SV

˚C

RUNSTOP MODE

For stable temperature, the heating plate and the bottom of block should be clean before using the instrument.

Heating plate

RUN ●TIME ●

HEAT ●ALM ●

PV

SV

˚C

RUNMODE

For precise test, Do not fill upreagent in the tube, keep theline inside the hole.

When you move this instruments, Please be careful not to drop.Because it is designed by very sensitive parts. Some impact couldbe cause fatal defects.

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNSTOP

MODE

Page 5: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

43

21

2

V022

1

This section summarizes operation procedures for MRC`s thermo bath controlling the temperature and the rotate.

Check the name rating plate for the correct voltage, then plug the power cord into thereceptacle on back of the instrument.

Plug the power cordinto the wall receptacle.

User operation

US

ER

OP

ER

AT

ION

* Temp. setting

Turn the power ON/OFF control button to position'ON'

When switch turn on, (the type of sensor)is displayed on PV and (software vision)isdisplayed on SV for1second.

After 1second,the current insidetemperature isdisplayed on PV andthe setting temperatureis displayed on SV.(This is NORMAL MODE)

In order to set thedesired TEMPERATURE,press MODE key for1.5seconds thenis displayed on PV and the rightmost number blinkon SV then stop pressingMODE key. Unless stop pressing MODE key, the setting return to NORMALMODE

p

When press MOVE Key, the rightmost number blink to moves in left. temperature range can be set per 0.1˚C. for example to set 45˚C, press MOVE key till the rightmost number blink to moves in the second placeof right.

※ Never touch an electrical socket or the power cord with wet hands.

4

3 4Put a block to the hole

Before place a block, check the bottom of block and insideheating plate clean.

RUN ●TIME ●

HEAT ●ALM ● PV

SV

˚C

RUNSTOP MODE

RUN ●TIME ●

HEAT ●ALM ● PV

SV

˚C

RUNSTOP MODE

RUN ●TIME ●

HEAT ●ALM ● PV

SV

˚C

RUNMODE

Page 6: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

3

2

5

US

ER

OP

ER

AT

ION

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

pWhen press UP key,the displayed figureincreases one by onethen press UP keycontinuously till thedisplayed figure reachesat 5.

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

The figure shouldbe displayed at 45.0 to use MOVE,UP and DOWN key, press MODE keyto complete the set.

* Timer & BEEP setting

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

0000

Press MODE key onceagain after the settingof the TEMPERATURE then is displayed on PVand is displayed on SV. TIME range canbe set to 99 Hours59minutes. Two positionsof the front are hour and next two positionsare minute. The method of TIMER setting is thesame as the method ofTEMPERATURE setting.

I e I e

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

0000Eep

PPress MODE key onceagain after TIME settingthen is displayed on PV and 0000 is displayed on SV. sound time can be set to9999times.The method of BEEPsound time setting is the same as the method ofTEMPERATURE setting and TIMER setting.

EepP

EepP

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

Press MODE key onceagain after the settingof BEEP sound timethen the screen returnto the NORMAL MODE.

5

User operation

6

1

Page 7: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

5

43

21

US

ER

OP

ER

AT

ION

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

After finishing the setting,press RUN key for 1.5seconds. Then RUN lamp is on and temperature rises in beginning. If the TIMER has been set, TIME lamp will be on till to reach the setting TEMPERATURE. TIMERwill start when the temperature has reached the setting TEMPERATURE.※ Unless the TIMER is sets, TIME lamp is not on.

* RUN & Check

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

HEAT lamp let you know that heater normallywhile the unit is running.

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

If the TIMER is set andyou want to see theset value while the unitis running, press UP key once then SV will be changedsetting TEMPERATUREto TIMER.

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

45.0

After the setting TIMERhas passed, is displayed on SV andthe setting BEEP soundbeeps for the settingBEEP sound time.Then press stop key BEEPsound will be stoppedand will be return toNORMAL MODE.

STOP

RUN ●

TIME ●

HEAT ●

ALM ●

PV

SV

˚C

RUNMODE

STOP

The existing setting TEMPERATURE, TIMER and BEEP sound time are kept in memory. Therefore,Pressing the RUN key 1.5 seconds before the unitwill operate the same way as.If you want to change thesetting TEMPERATURE, TIMER and BEEP sound time,please start to reset all of thesetting value.

6

User operation

Page 8: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

Accessories

AC

CE

SS

OR

IES

7

NON-STANDARDS CAN BE MADE BY ORDER

- DIMENSION (mm) : W129 X D100 X H55

0.5ml centrifuge tube : 63holesAB100-0563

1.5ml centrifuge tube : 48holesAB100-1548

96PCR plate : 1ea or8strip tube : 12ea

AB100-961.5ml centrifuge tube : 24holesAB100-1524 (with Rack)

50ml conical tube : 8holesAB100-508

15ml conical tube : 16holesAB100-1516

TM

JD-90

Cover

CVH4-80 CVH2-80 CVH1-80 CVC1-80

CVH4-F CVH2-F CVH1-F CVC1-F

- DIMENSION (mm) : W129 X D100 X H78

Page 9: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

Faulty running

Always unplug the instrument before you start cleaning it.

Never immerse the appliance in water.

This equipment is maintenance-freeClean the surfaces of the heated bath at regular interval- water containing a surfactant detergent additive.- Isopropyl alcohol

.

Never use the instrument if the plug, the cord or the instrument itself is damaged.

Maintenance and Cleaning

MA

INT

EN

AN

CE

AN

D C

LE

AN

ING

& F

AU

LT

Y R

UN

NIN

G

1. The thermometer and setting temperature is different - Thermometer may not correspond each certification authorities.

2. When you turn on the power switch, the lights don’t work. - You can find the fuse box for spare one in the power module as the below drawings.

If the equipment have other defects, It should be informed to an authorized servicing agent.

Pull the fuse case using a small driver or other tool Push the fuse case

Find the fuse case on the power socket Take the new fuseRemove used fuse

Spare fuse

8

Page 10: Thermo bath & cool block DBD-H SERIES Operating Manual Operating Manual · 2018-09-25 · Operating Manual Operating Manual Thermo bath & cool block DBD-H SERIES Operating Manual

Warranty

1 YEAR WARRANTY

Limited Warranty :

This equipment has been tested all the functions and parts for proper operationbefore shipment.Please read this manual carefully. If youhave any questions or problems, checkwith your dealer or write us direct.This equipment is warranted for a period of 1year from date of purchase againstdefects in workmanship and material only.If a system component should ever fail to work perfectly. It can be repaired or replaced by our after-sales service withoutdifficulty.

Model#:

Serial# :

Date Purchased :

Dealer Name :

City and Country :

WA

RR

AN

TY