www.tracopower.com 6 TMR-6WI Series 6W Highest power density in SIP package Smallest footprint 6W converter Operating temperature -40 to +71 °C without derating Ultra wide 4:1 input range Fully regulated outputs I/O isolation 1500 VDC No minimum load required Models DC/DC Converter Order code Input voltage Output voltage Output current max. TMR 6-2410WI 3.3 VDC 1500 mA TMR 6-2411WI 5 VDC 1200 mA TMR 6-2419WI 9 VDC 666 mA TMR 6-2412WI 9-36 VDC 12 VDC 500 mA TMR 6-2413WI 15 VDC 400 mA TMR 6-2415WI 24 VDC 250 mA TMR 6-2421WI ± 5 VDC ± 600 mA TMR 6-2422WI ± 12 VDC ± 250 mA TMR 6-2423WI ± 15 VDC ± 200 mA TMR 6-4810WI 3.3 VDC 1500 mA TMR 6-4811WI 5 VDC 1200 mA TMR 6-4819WI 9 VDC 666 mA TMR 6-4812WI 18-75 VDC 12 VDC 500 mA TMR 6-4813WI 15 VDC 400 mA TMR 6-4815WI 24 VDC 250 mA TMR 6-4821WI ± 5 VDC ± 600 mA TMR 6-4822WI ± 12 VDC ± 250 mA TMR 6-4823WI ± 15 VDC ± 200 mA THM-3WI Series 3W Ultra wide 4:1 input voltage range I/O isolation voltage 5000 VACrms reinforced insulation Rated for working voltage 250 VAC Medical safety to IEC/EN60601-1 3rd edition, 2 x MOPP % Order code Input voltage Output voltage Output current max. THM 3-0510WI 3.3 VDC 1000 mA THM 3-0511WI 5 VDC 600 mA THM 3-0512WI 12 VDC 250 mA THM 3-0513WI 4.5-9 VDC 15 VDC 200 mA THM 3-0515WI 24 VDC 125 mA THM 3-0521WI ± 5 VDC ± 300 mA THM 3-0522WI ± 12 VDC ± 125 mA THM 3-0523WI ± 15 VDC ± 100 mA THM 3-2410WI 3.3 VDC 1000 mA THM 3-2411WI 5 VDC 600 mA THM 3-2412WI 12 VDC 250 mA THM 3-2413WI 9-36 VDC 15 VDC 200 mA THM 3-2415WI 24 VDC 125 mA THM 3-2421WI ± 5 VDC ± 300 mA THM 3-2422WI ± 12 VDC ± 125 mA THM 3-2423WI ± 15 VDC ± 100 mA THM 3-4810WI 3.3 VDC 1000 mA THM 3-4811WI 5 VDC 600 mA THM 3-4812WI 12 VDC 250 mA THM 3-4813WI 18-75 VDC 15 VDC 200 mA THM 3-4815WI 24 VDC 125 mA THM 3-4821WI ± 5 VDC ± 300 mA THM 3-4822WI ± 12 VDC ± 125 mA THM 3-4823WI ± 15 VDC ± 100 mA Models DC/DC Converter 5.0 (0.2) 4.5 ±0.5 22.86 (0.9) 20.3 ±0.5 (0.8 ±0.02) 2.54 32 ±0.5 (1.25 ±0.02) 10.2 ±0.5 (0.4 ±0.02) 15.24 (0.6) 11 22 23 2 16 14 Bottom view 15.24 (0.6) 5.08 2.4 ±0.5 (0.8 ±0.02) (0.1 ±0.02) (0.18 ±0.02) (0.1) (0.2) C B Scheme Pin-Out Pin Single Dual 1 -Vin(GND) -Vin(GND) 2 +Vin(Vcc) +Vin(Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 6 +Vout +Vout 7 -Vout Common 8 No con. -Vout Reinforced Insulation C B Scheme Pin-Out Pin Single Dual 2 -Vin(GND) -Vin(GND) 11 No con. -Vout 14 +Vout +Vout 16 -Vout Common 22 +Vin(Vcc) +Vin(Vcc) 23 +Vin(Vcc) +Vin(Vcc) pending bottom view 3.2 (0.13) 0.5 (0.02) 0.25(0.01) 2.0 21.8 5.08 3 x 2.54 0.5 (0.02) 11.2 (0.44) (3 x 0.1) (0.08) (0.2) 4.1 2 x 2.54 (2 x 0.1) (0.86) (0.16) 9.1 (0.36) 1 2 3 5 6 7 8 Line regulation 0.5 % max. Load regulation single output models: 0.2 % max. dual output models: 1 % max. Conducted EMI 85 % typ. Operating temperature –40 ° C to +85 ° C (with derating, tba) Safety standards/ approvals (pending) IEC/EN60601-1 3rd edition, 2 x MOPP, UL 60601-1 I/O isolation voltage 5000VAC (60 sec.), reinforced insulation rated for 250VAC working voltage, clearance/creepage 8mm I/O isolation capacitance 17pF max. Full datasheet www.tracopower.com/products/thm3wi.pdf Line regulation 0.2 % max. Load regulation 0.5 % max. ; 1 % max. for dual output models 83 % typ. Operating temperature –40 ° C to +71 ° C (without derating) I/O isolation voltage 1500VDC (60 sec.) Remote On/Off shutdown input for low input current (2.5mA) in standby operation Full datasheet www.tracopower.com/products/tmr6wi.pdf Full datasheet in progress Full datasheet in progress

Upload: others

Post on 16-Oct-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THM-3WI Series 3W

www.tracopower.com6

TMR-6WI Series 6W Highest power density in SIP package

Smallest footprint 6W converter

Operating temperature -40 to +71 °C without derating

Ultra wide 4:1 input range

Fully regulated outputs

I/O isolation 1500 VDC

No minimum load required

Models

DC/DC Converter

Order code Input voltage Output voltage Output current max.

TMR 6-2410WI 3.3 VDC 1500 mA

TMR 6-2411WI 5 VDC 1200 mA

TMR 6-2419WI 9 VDC 666 mA

TMR 6-2412WI 9-36 VDC 12 VDC 500 mA

TMR 6-2413WI 15 VDC 400 mA

TMR 6-2415WI 24 VDC 250 mA

TMR 6-2421WI ± 5 VDC ± 600 mA

TMR 6-2422WI ± 12 VDC ± 250 mA

TMR 6-2423WI ± 15 VDC ± 200 mA

TMR 6-4810WI 3.3 VDC 1500 mA

TMR 6-4811WI 5 VDC 1200 mA

TMR 6-4819WI 9 VDC 666 mA

TMR 6-4812WI 18-75 VDC 12 VDC 500 mA

TMR 6-4813WI 15 VDC 400 mA

TMR 6-4815WI 24 VDC 250 mA

TMR 6-4821WI ± 5 VDC ± 600 mA

TMR 6-4822WI ± 12 VDC ± 250 mA

TMR 6-4823WI ± 15 VDC ± 200 mA

THM-3WI Series 3W Ultra wide 4:1 input voltage range

I/O isolation voltage 5000 VACrms reinforced insulation

Rated for working voltage 250 VAC

Medical safety to IEC/EN60601-1 3rd edition, 2 x MOPP

%

Order code Input voltage Output voltage Output current max.

THM 3-0510WI 3.3 VDC 1000 mA

THM 3-0511WI 5 VDC 600 mA

THM 3-0512WI 12 VDC 250 mA

THM 3-0513WI 4.5-9 VDC 15 VDC 200 mA

THM 3-0515WI 24 VDC 125 mA

THM 3-0521WI ± 5 VDC ± 300 mA

THM 3-0522WI ± 12 VDC ± 125 mA

THM 3-0523WI ± 15 VDC ± 100 mA

THM 3-2410WI 3.3 VDC 1000 mA

THM 3-2411WI 5 VDC 600 mA

THM 3-2412WI 12 VDC 250 mA

THM 3-2413WI 9-36 VDC 15 VDC 200 mA

THM 3-2415WI 24 VDC 125 mA

THM 3-2421WI ± 5 VDC ± 300 mA

THM 3-2422WI ± 12 VDC ± 125 mA

THM 3-2423WI ± 15 VDC ± 100 mA

THM 3-4810WI 3.3 VDC 1000 mA

THM 3-4811WI 5 VDC 600 mA

THM 3-4812WI 12 VDC 250 mA

THM 3-4813WI 18-75 VDC 15 VDC 200 mA

THM 3-4815WI 24 VDC 125 mA

THM 3-4821WI ± 5 VDC ± 300 mA

THM 3-4822WI ± 12 VDC ± 125 mA

THM 3-4823WI ± 15 VDC ± 100 mA

Models

DC/DC Converter

5.0

(0.2)

4.5 ±0.522.86 (0.9)

20.3 ±0.5 (0.8 ±0.02)

2.54

32 ±0.5 (1.25 ±0.02)

10.2 ±0.5

(0.4 ±0.02)

15.24 (0.6)

11

2223 2

1614

Bottom view

15.24 (0.6)5.08

2.4 ±0.5

(0.8 ±0.02)

(0.1 ±0.02)

(0.18 ±0.02 )

(0.1)(0.2)

C BScheme

Pin-OutPin Single Dual

1 -Vin(GND) -Vin(GND)

2 +Vin(Vcc) +Vin(Vcc)

3 Remote On/Off Remote On/Off

5 No con. No con.

6 +Vout +Vout

7 -Vout Common

8 No con. -Vout

Reinforced Insulation

CBScheme

Pin-OutPin Single Dual

2 -Vin(GND) -Vin(GND)

11 No con. -Vout

14 +Vout +Vout

16 -Vout Common

22 +Vin(Vcc) +Vin(Vcc)

23 +Vin(Vcc) +Vin(Vcc)

pending

bottom view

3.2

(0.1

3)

0.5 (0.02)

0.25

(0.0

1)

2.0

21.8

5.08 3 x 2.54

0.5

(0.0

2)

11.2

(0.4

4)

(3 x 0.1)(0.08) (0.2)

4.1

2 x 2.54

(2 x 0.1)

(0.86)

(0.1

6)

9.1

(0

.36)

1 2 3 5 6 7 8

Line regulation 0.5 % max.

Load regulation single output models: 0.2 % max.dual output models: 1 % max.

Conducted EMI

85 % typ.

Operating temperature –40 ° C to +85 ° C (with derating, tba)

Safety standards/approvals (pending)

IEC/EN60601-1 3rd edition, 2 x MOPP, UL 60601-1

I/O isolation voltage 5000VAC (60 sec.), reinforced insulation rated for250VAC working voltage, clearance/creepage 8mm

I/O isolation capacitance 17pF max.

Full datasheet www.tracopower.com/products/thm3wi.pdf

Line regulation 0.2 % max.

Load regulation 0.5 % max. ; 1 % max. for dual output models

83 % typ.

Operating temperature –40 ° C to +71 ° C (without derating)

I/O isolation voltage 1500VDC (60 sec.)

Remote On/Off shutdown input for low input current (2.5mA)in standby operation

Full datasheet www.tracopower.com/products/tmr6wi.pdf