THREEPHASERELAYS
NFC
PHASE/
NEUTRAL LOSS
PHASE REVERSAL
PHASE ASYMMETRY
UNDER VOLTAGE
OVER VOLTAGE
TIME DELAY
UL LISTED
LPMRN/2Programmable using Smartphone with NFC
Dims: to DIN 43880W. 17.5mm
LPRC/2Under & Over Voltage, Phase Loss + Sequence
LPRT/2Under Voltage, Phase Loss + Sequence
LPRD/2Under Voltage, Phase Loss, Sequence + Restart Delay
Dims: to DIN 43880W. 17.5mm
Dims: to DIN 43880W. 17.5mm
Dims: to DIN 43880W. 17.5mm
Key Features:Ÿ True R.M.S. monitoringŸ Selectable nominal voltages to suit most popular 3-wire/4-wire supply voltagesŸ Monitors own supply and measures phase to phase (3-wire monitoring) or
phase to neutral (4-wire monitoring) voltagesŸ Detects an Under voltage condition on one or more phasesŸ 1 Detects incorrect phase sequence, phase and neutral loss Ÿ Delay to relay re-energising adjustable Ÿ DPDT relay output - 5AŸ Green LED indication for supply status and Red LED indication for relay status
1 when 4-wire mode selected
THREE PHASE RELAYS
Key Features:Ÿ True R.M.S. monitoringŸ Selectable nominal voltages to suit most popular 3-wire/4-wire supply voltagesŸ Monitors own supply and measures phase to phase (3-wire monitoring) or
phase to neutral (4-wire monitoring) voltagesŸ Detects an Under voltage condition on one or more phasesŸ 1 Detects incorrect phase sequence, phase and neutral loss Ÿ DPDT relay output - 5AŸ Green LED indication for supply statusŸ Red LED indication for relay status
1 when 4-wire mode selected
Key Features:Ÿ True R.M.S. monitoringŸ Selectable nominal voltages to suit most popular 3-wire/4-wire supply voltagesŸ Monitors own supply and measures phase to phase (3-wire monitoring) or
phase to neutral (4-wire monitoring) voltagesŸ Detects if one or more phases exceed the set Under or Over voltage trip levelsŸ 1 Detects incorrect phase sequence, phase and neutral loss Ÿ Independent relay outputs - Under voltage and Over voltage monitoringŸ 2 x SPDT relay output - 5AŸ Green LED indication for supply status and individual Red LED indication for both relay statuses
1 when 4-wire mode selected
Key Features:Ÿ Programmable functions for total flexibilityŸ CustomisableŸ Monitors own supply (3 and 4-wire)Ÿ Configurable trip and time settingsŸ Multi-voltage supply optionsŸ 2 x SPDT independent relays outputs assignable to various functionsŸ Intelligent LED indication
Benefits:ü User profiles for quick/convenient setting up using appü Real time monitoring of supply ü Compact size (only 17.5mm wide)ü Clone settings on further unitsü Accuracy - 100% digital settingü Tamperproofü Program power appliedwithout
LPMP/2 & LPRA/2Phase Asymmetry, Under & Over Voltage, Phase Loss+ Restart Delay
PUVR44Phase Under Voltage (High Immunity)
LXPRC/S & LXPRC/S-4WUnder & Over Voltage, Phase Loss + Sequence
LXPRC & LXPRC-4WUnder & Over Voltage + Phase Loss
Dims: to DIN 43880W. 17.5mm
Dims: to DIN 43880W. 44mm
Dims: to DIN 43880W. 17.5mm
Dims: to DIN 43880W. 17.5mm
Key Features:Ÿ True R.M.S. monitoringŸ Selectable nominal voltages to suit popular 3-wire/4-wire supply voltagesŸ Monitors own supply Ÿ Detects phase asymmetry/unbalance and if one or more phases exceed the fixed Under or Over voltage trip levels (LPRA/2 Under voltage trip level only)Ÿ 1 Detects incorrect phase sequence, phase and neutral loss Ÿ Delay to relay re-energising adjustable (LPMP/2 only)Ÿ DPDT relay output - 5AŸ Green LED indication for supply status and Red LED for relay status
Key Features:Ÿ Designed to withstand voltage overloads up to 125% (cont.), 150% (10s)Ÿ Selectable nominal voltages (220, 230, 240, 254, 265, 277V (L>N))Ÿ Monitors own supply and measures phase to neutral voltagesŸ Detects an Under voltage condition on one or more phasesŸ Adjustable Differential and Under voltage trip levelŸ Adjustable time delayŸ DPDT relay output - 8AŸ Green LED indication for supply statusŸ Red LED indication for relay status
Key Features:Ÿ True R.M.S. monitoringŸ Can be specified for supplies110, 208, 220, 380, 400 or 415VŸ Monitors own supply and measures phase to phase voltages (phase to neutral on LXPRC/S-4W)Ÿ Detects if one or more phases exceed the set Under or Over voltage trip levelsŸ Detects incorrect phase sequence and phase loss (plus neutral loss on LXPRC/S-4W)Ÿ Adjustable Under and Over voltage trip levelsŸ Adjustable time delay to prevent nuisance trippingŸ 1 x SPDT relay output - 8AŸ Green LED indication for supply and Red LED for relay status
Key Features:Ÿ True R.M.S. monitoringŸ Can be specified for supplies110, 208, 220, 380, 400 or 415V Ÿ Monitors own supply and measures phase to phase voltages (phase to neutral on LXPRC-4W)Ÿ Detects if one or more phases exceed the set Under or Over voltage trip levelsŸ Detects phase loss (and neutral loss on LXPRC-4W) and operates irrespective of phase sequenceŸ Adjustable Under and Over voltage trip levelsŸ Adjustable time delay to prevent nuisance trippingŸ 1 x SPDT relay output - 8AŸ Green LED indication for supply and Red LED for relay status
1 when 4-wire mode selected
THREE PHASE RELAYS
19
63
- 2
01
3
LXPRF & LXPRF-4WPhase Loss + Sequence
Key Features:
Ÿ True R.M.S. monitoring
Ÿ Suits key global supply voltages
Ÿ Monitors own supply and measures phase to phase voltages (phase to neutral on LXPRF-4W)
Ÿ Detects an Under voltage condition on one or more phases
Detects incorrect phase sequence and Ÿ phase loss (plus neutral loss on LXPRF-4W)
Fixed Under voltage trip levelŸ Fixed time delayŸ 1 x SPDT relay output - 8AŸ Green LED indication for supply statusŸ Red LED indication for relay statusŸ
LXPRT & LXPRT-4WUnder Voltage, Phase Loss + Sequence
LXPRC/S/FUnder & Over Voltage, PhaseLoss + SequenceKey Features:
Ÿ True R.M.S. monitoring
Ÿ Designed primarily for supplies400/415V
Ÿ Monitors own supply and measures phase to phase voltages
Ÿ Detects if one or more phases exceed the fixed Under or Over voltage trip levels
Ÿ Detects incorrect phase sequence and phase loss
Fixed Under/Over voltage trip levelsŸ Adjustable time delay to prevent nuisance Ÿ
tripping
1 x SPDT relay output - 8AŸ Green LED indication for supply status/faultŸ
condition
Ÿ Red LED indication for relay status
LXPRC/S/RDUnder & Over Voltage, Loss, Sequence + Restart DelayKey Features:
Ÿ True R.M.S. monitoring
Ÿ Selectable nominal voltages
Ÿ Two ranges available:Ÿ 208/220VŸ 380/400/415/440/460V
Ÿ Monitors own supply and measures phase to phase voltages
Ÿ Detects if one or more phases exceed the fixed Under or Over voltage trip levels
Detects incorrect phase sequence and loss Ÿ Fixed Under/Over voltage trip levels (+/-10% of Ÿ
selected nominal)
Adjustable Restart time delayŸ (1 - 500s)
1 x SPDT relay output - 8AŸ Green LED indication for supply statusŸ Red LED indication for relay statusŸ
Dims: to DIN 43880
W. 17.5mm
Dims: to DIN 43880
W. 17.5mm
Dims: to DIN 43880
W. 17.5mm
Dims:to DIN 43880
W. 17.5mm
NOTE: Many other versions and options available which can be customised to suit your requirements!
Broyce Control Ltd. Pool Street, Wolverhampton, West Midlands, WV2 4HN. U.K.Tel: +44 (0) 1902 773746 Fax: +44 (0) 1902 420639Email: [email protected] Web: www.broycecontrol.com
3-P
has
e Sh
ort
form
20
19
Key Features:
Ÿ True R.M.S. monitoring
Ÿ Suits key global supply voltages
Ÿ Monitors own supply and measures phase to phase voltages (phase to neutral on LXPRT-4W)
Ÿ Detects an Under voltage condition on one or more phases
Detects incorrect phase sequence and Ÿ phase loss (plus neutral loss on LXPRT-4W)
Adjustable Under voltage trip levelŸ Adjustable time delay to prevent nuisance Ÿ
tripping
1 x SPDT relay output - 8AŸ Green LED indication for supply statusŸ Red LED indication for relay statusŸ