three stage pulse tube cryocoolers

19
Three stage pulse tube cryocooler Guided by: Prof. S. M. Mehta Prepared by: Vivek P. Sarvaiya

Upload: viky4640

Post on 16-Jan-2016

11 views

Category:

Documents


0 download

DESCRIPTION

this is presentation of the report i have uploaded earlier

TRANSCRIPT

Page 1: three stage pulse tube cryocoolers

Three stage pulse tube cryocooler

Guided by:

Prof. S. M. Mehta

Prepared by:Vivek P. Sarvaiya

Page 2: three stage pulse tube cryocoolers

cryocoolers• What is cryocoolers?

• Cryocoolers are small refrigerators that can reach cryogenic temperatures and provide refrigeration in the temperature below 120 K.

• Why cryocoolers are required?

• long lifetime

• reliable and maintenance free operation

• minimum vibration and noise

• Compactness

• Lightweight

• adequate refrigeration at specified temperature with low power input

Page 3: three stage pulse tube cryocoolers

Applications

• Liquefaction of gases such as nitrogen, oxygen, hydrogen, helium, natural gas

• Cooling of super-conducting magnets

• Cooling of infra-red sensors for missile guidance

• Cryo vacuum pumps

• SQUID magnetometers

• Gamma ray sensors for monitoring nuclear activity

• Cooling of high temperature superconductors and semiconductors

Page 4: three stage pulse tube cryocoolers

Classification•Recuperative cryocoolers

• Joule-Thomson

• Bryton

• Claude

•Regenerative cryocoolers

• Stirling

• Pulse tube

• Gifford-McMahon

Page 5: three stage pulse tube cryocoolers

Pulse tube Cryocoolers

• W. E. Gifford and R. C. Longsworth, in 1960's, invented the so-called Basic Pulse Tube.

• The modern PTR was invented by Mikulin by introducing orifice in Basic pulse tube in 1984. He reached a temperature of 105 K.

Page 6: three stage pulse tube cryocoolers

Progress of pulse tube

Page 7: three stage pulse tube cryocoolers

Single-stage Stirling-PTR

AC

Regenerator

Cold Heat Exchanger

Pulse Tube

Hot Heat Exchanger

Orifice

ReservoirCompressor

• Regenerator: A matrix as a porous media having high heat capacity and low conductivity to exchange the heat with the gas (heart of the system).

• Hot heat exchangers: Release the heat created in the compression cycle to the environment.

• Cold heat exchangers: Absorbs the heat of the environment because of cooling down in the expansion cycle.

Page 8: three stage pulse tube cryocoolers

• After cooler (AC): Remove the heat of the compression in the compressor.

• Buffer: A reservoir having much more volume in compare with the rest of the system.

• Orifice: An inlet for the flow resistance.

• Compressor: Creating a harmonic oscillation for the gas inside the system.

AC

Regenerator

Cold Heat Exchanger

Pulse Tube

Hot Heat Exchanger

Orifice

ReservoirCompressor

Page 9: three stage pulse tube cryocoolers

Pulse tube coolers(WHY??)

• Reliable and Maintenance free operation

• No rubbing seals and rubbing forces due to replacement of displacer.

• Least Vibration at the cold tip due Elimination of cold moving parts.

Page 10: three stage pulse tube cryocoolers

How to achieve lower and lower temperature????

Page 11: three stage pulse tube cryocoolers

RESEARCHER

UNIT TYPE Pressure (bar)

Frequency (Hz)

Lowest temperature

Power Input

1st stage

2nd stage

Yang andThummes

‘U’ typeGas-Coupled

20.6 35 72 K 20.02 K 200 W

Radebaughet al

‘U’ typeThermally-Coupled

24.1 32.3 60 K 20 K 600 W

Chen et al ‘U’ typeThermally-Coupled

12 32 93.3 K 14.2 K 400 W

Page 12: three stage pulse tube cryocoolers

Three-Stage Stirling -PTR Reservoir 1 Reservoir 2 Reservoir 3

Orifice 1

Pulse-Tube 1

Reg. 1

Reg. 2

Reg. 3

Aftercooler

Compressor

Orifice 3

Pulse-Tube 3

Orifice 2

Pulse-Tube 2

Stage 1

30-100 K

15 k

4 k

Page 13: three stage pulse tube cryocoolers

Three stage pulse tube cryocooler

Operating condition of three stage pulse tube refrigerator

Y. Matsubara and J.L. Gao , cryogenics 34

Page 14: three stage pulse tube cryocoolers
Page 15: three stage pulse tube cryocoolers

Three stage pulse tube cryocooler1st stage: 37 W @ 45 K

2nd stage:15W @ 15 K

3rd stage:0.3 W @ 3.96 K

C.Wang, Cryocooler 14

Page 16: three stage pulse tube cryocoolers

Three stage pulse tube cryocoolerParameter 1st stage 2nd stage 3rd stage

Frequency (Hz) 40 30 30

Mean Pressure

(MPa)

2.0 1.0 1.0

PV Input Power

(W)

250 170 60

Bottom

Temperature (K)

37 11 4.9

Cooling power 15W@80K 1.4W@20K 60mW@6

K

Relative Carnot 16.5% 11.5% 4.9%

Required

Precooling

None 8W@90K 4.5W@90

K

1.2W@20

K

Q. Cao et al, Cryocoolers 16

Page 17: three stage pulse tube cryocoolers

Application of pulse tube cryocooler

• Military – Night vision Infrared Camera

• Space and Satellite – Infrared detector cooling

• Cryopumps

• Gas Cooling and Gas Liquefaction

• MRI and NMR SC Magnet cooling

• SC Transformer Motor and Generator

Page 18: three stage pulse tube cryocoolers

conclusion

• Staging in pulse-tube reduces the cooling power in subsequent stages.

• Staging in pulse tube cryocoolers decreases the temperature as stages increases

• Cooling power keep on reducing as stages keep on increasing.

Page 19: three stage pulse tube cryocoolers

Thank you

• Presented by

• Vivek Sarvaiya