time switch catalogue - indiamartimghost.indiamart.com/data/b/k/my-683236/timeswitch.pdf · 2020....
TRANSCRIPT
TIME SWITCHES
Time Switches
On 8th August 1958, a young entrepreneur manufactured,
India's first indigenously developed, sheet steel enclosed
rewirable switch at Jalandhar in Punjab, marking the birth of Indo
Asian. Nearly Half a century later, Indo Asian has a proven track
record of manufacturing and marketing a wide range of high
quality electrical control & protection products, which include
electrical safety devices such as Indo Kopp MCBs, Stopshock
RCCBs, HRC Fuselinks, Indo Asian Wires & Cables, Insulated
Industrial Plugs & Sockets, Hausmann Modular Wiring
Accessories and of course ecofriendly energy saving Compact
Fluorescent Lamps.
Indo Asian's product portfolio reflects its philosophy of social
responsibility.At IndoAsian, on one hand we manufacture devices
which make the use of electricity safe & convenient, on the other
hand, ecofriendly energy saving Compact Fluoresent Lamps
conserve scarce electrical power. Indo Asian has installed the
largest integrated and automated CFL manufacturing setup in
south East Asia to produce a wide range of Smart Compact
Fluorescent Lamps which are used in homes, offices, hotels,
entertainment arenas, shopping arcades, public areas, housing
colonies etc. enabling these users to conserve nearly 80%
electrical energy conventionally used for lighting. Thus
addressing a crucial need of the nation.
The group's pursuit of excellence backed by extensive in-
house R&D, technical and commercial collaborations with world's
best renowned companies such as Heinrich Kopp AG, Doepke &
Co. AG., and Theben AG Werke Zeitautamatic GmbH, all from
Germany and ETI Elektorelement d.d. of Slovenia of all have
resulted in bringing world class products from all the 5 modern and
state-of-the art manufacturing units of Sonepat, Jalandhar, Noida
and Parwanoo.
Because we have a Responsibility
The Technology Edge
Time Switches
Theben
The Philosophy
The abilities of Theben AG lies in solutions for time, lighting and
climate control. Within time switching devices, modules or bus-
systems, Theben produces the highest quality products in every
range. Theben offers not only time switches in analog and digital
technology with classical switch tappets or segments, but also
microprocessor-controlled digital devices that offer hours, days,
weeks and years programs and an extensive program of sensors
and actuators for the EIB bus technology. On top of this Theben is
well known for its stair, light and twillight switches and for its clock
thermostats that allow a power saving heating control.
Theben offers its clients a tailored solution for all applications and
situations. Theben AG manufacturing plants in Germany, Great
Britain, France, Italy and Switzerland and is one of the leading
producers of time switching devices and systems.
A worldwide presence in more than 54 countries with market
leading high-quality products form the basis for continual growth.
Theben products are very well-known for their user-firendly
operation, a high product quality and a first rate design.
In India the complete range of Theben products are made
available from "Indoasian Fusegear Ltd.
The company is certified according to the international DIN ISO
9001 standardisation.
We are an autonomous, independent, internationally operation
company with a high potential of innovation and a great many
profitable ideas and concepts for the future.
Our core competency encompasses the control and regulation of
time, light and climate.
We are recognized specialists, especially when it comes to timer
devices and other intelligent systems.
Our goals are innovation, high functionality, best quality,
dependability, continuity and calculability.
We are a dependable and competent partner to our customers,
offering competitive products and services.
The Theben company aims to serve, and continuously supports
the personal as well as the occupational qualification and
development of its staff members.
Analog Time Switches
SUL-189 s Segment Time Switch
Function :
�
�
�
�
�
�
Time switches with or without power reserve.
24 hour dial with segment of 15 min. Switching
time each.
Early ON/OFF over-ride switching without
inf luencing the subsequent program
sequence.
Permanent ON/OFF switching, e.g. for
holidays.
Changeover contact 10A/250V~.
Switching status indication.
Clock hands can be reset for switching over
between summer/winter time.
Technical Data :
Nominal voltage :
Power Consumption :
Permissible ambient temperature :
Time setting :
Contact :
Contact material :
Switching Capacity :
Housing and insulating material :
Electrical Connection :
Protection class :
Quartz time switch with power reserve Drive :
Mains frequency :
Accuracy :
Power reserve :
Full power reserve :
Weight :
Design :
230 V ~±10%
Max. 2.5 VA.
-10ºC..+50ºC
analog with clock hands, also possible anti-clockwise.
Floating, gap less than 3 mm (µ).
Hard silver, gold-plated.
10A/250 V ~, cos =1
2A/250 V ~, cos =0.6.
high temperature-resistant,fireproof thermoplastics.
screw terminal or 4.8 mm tabconnectors.
II in accordance with EN 60730-1 if installed asdirected.
quartz-controlled stepping motor.
45-60 Hz.
± 1 Sec./day at 20ºC.
Approx. 72 hours on fully charge battery at 20ºC
approx. 3 days after connection to operatingvoltage.
Approx. 260g.
Front frame 72 x 72 mm
Switch panel mounting with clip fastening. Connection eitherwith tab connectors (4.8mm) or with screw terminals using theplug-in base.
Surface mounting with plug-in base and terminal cover.
Can also be mounted on a 35 mm top-hat rail with additionalparts or on PC boards with plug connector.
Transparent cover protects against dirt and unintentionaladjustment.
�
�
�
�
�
�
�
�
Type Program Power reserve Switching Programmable Minimum Switching Nominal Order No.dial approx. segments every... switching interval contacts current at 250~
SUL189 s 24 hours 3 days 96 15 min. 15 min. 1Changeover Switch 10 (2)A T1890801
72
104
65 25
7266
10
54
69
Analog Time Switches
54
110
*
65.5
60
45.5
47*
90 45
LN
1 2 3 7 8
M~
Type Program Power reserve Switching Programmable Minimum Switching Nominal Order No.dial approx. segments every... switching interval contacts current at 250~
SUL181 h 24 hours 3 d 48 30 min. 30min. 1 Changeover 16 (4)A T1810008Switch
SUL 181 h Segment Time Switch
Function :
�
�
�
�
�
�
�
�
Time switches with power reserve.
24 hour dial with 30 min. segments or 60 min
dial with 75s segments.
Early manual over-ride switching for on and
off without influencing the subsequent
program sequence.
Permanent ON/OFF switch.
Switching status indication.
Fine adjustment for time setting accurate to the
minute.
Summer/winter time correction ± 1 hour by
the bi-directional fine time adjustment facility.
Operating indication.
TECHNICAL DATA:
Nominal voltage :
Permissible ambient temperature :
Power Consumption :
Contact :
Contact material :
Housing and insulating material:
Enclosure type :
Protection class :
Test Approvals :
Quartz time switches with power reserve :
Drive :
Mains frequency :
Accuracy :
Power reserve :
Weight :
DESIGN :
230V ~ ± 10%
- 20ºC... +50ºC.
Max. 2.5 VA.
Floating, gap less than 3 mm (µ).
Hard silver.
High temperature-resistant,fireproof thermoplastics.
IP 20 in accordance with EN 60529.
II in accordance with EN 60 730-1 if installed asdirected.
national and international depending on devicetype.
quartz-controlled stepping motor.
45-60 Hz.
= ± 1 sec./day at 20ºC.
upto 72hours on fully charged battery.
approx. 150g.
Standard housing 45x54x60(mm).
Snap-on fixing for 35mm top-hat rail (DIN EN 50022).
Surface-mounting with additional terminal cover, tamper proofing.
Tamper proof operating panel protects against undesiredprogramming interventions.
Shock protection in accordance with accident preventionregulation VBG 4.
Captive terminal screws.
�
�
�
�
�
�
Analog Time Switches
SUL 180 a Segment Time Switch
Function :
�
�
�
�
�
�
Time switches with 24 h or 7 day segment dial.
Programming by 15 minutes segments in the
day program.
Programming by 2 hours segments in the week
program.
Permanent ON/OFF switch.
Normally open contact 16A/250V~
Switching status indication
Technical Data :
Nominal voltage :
Frequency :
Power Consumption : ,
Contact :
Contact material :
Switching Capacity :
Accuracy :
Power reserve :
Permissible ambient temperature :
Housing and insulating material : -
Test approvals :
Protection class :
Weight :
Design :
230V ~ ± 10%
45-60 Hz
Approx. 2 5VA
Floating, gap less than 3 mm (µ).
Ag Cd O
16A 250 V ~, cos =1
4A, 250 V ~, cos =0.6.
= ± 1 sec. /day at 20ºC.
approx. 3 days at 20ºC
-10ºC...+50ºC
high temperature resistant,
fireproof thermoplastic.
national and international depending on device
type.
II in accordance with EN60730-1 if installed as
directed.
approx. 120 g.
Standard housing 45 x 17,5 x 60 (mm)
Snap-on fixing for 35 mm top-hat rail (EN 50022)
Tamper proof transparent cover protects against undesired
programming interventions.
Shock protection in accordance with accident prevention
regulation VBG 4.
Captive terminal screws.
�
�
�
�
�
�
�
�
65.5
60
55.5*
90 45
LN
1 2 3 4
M~
128*
34*
17.5
Type Program Power reserve Switching Programmable Minimum Switching Nominal Order No.dial approx. segments every... switching interval contacts currentat250~
SUL180a 24 hours 3 d 96 1/4 hour 1/4 hour 1 Working 16(4)A T1800001Contract
Type Detection Mounting Brightness Time Range Switching contacts Nominal CurrentAngle Height Range
LU 10-180 180º Min 2m 0...1000 lux 5 sec...12 min. 10A, 230 V~Max 14m.
Caution : the detection range and quality depends on ambient temperature and the axis in which the movement takes place in relation to the product. The
range is greater when the movement is across the field of view of the sensor rather than directly towards it.
Motion Detector
LU 101-46 Motion Detector
Function :
�
�
�
�
�
�
�
�
�
�
�
Motion detector for mounting on exterior housewall or corner.
Detector functioning by passive infraredtechnology.
Reacts to the temperature variations resultingfrom moving bodies, cars etc.
For increased safety and convenience aroundthe home.
Automatic switch-on off connected lightingwhen detection area is entered and delayedswitch-off when area is left.
Suitable for controlling lighting in house andgarage entrances, hall, stairs, garden, storagerooms etc.
Energy saving because the lampsautomatically switch off after a predeterminedtime (adjustable timing).
Integral photoelectric cell preventing switchingon during daylight.
Timing is restarted every time a motion isdetected.
Quick installation and adjustment.
White housing.
Technical Data :
Detection angle :
Distance :
Switching capacity :
Incandescent lamps :
Halogen lamps :
Fluorescent lamps :
Dimensions :
180º
14 m max. depending on the adjustment of the sensor,on the surrounding temperature and on the direction of approach.
10A/230 V~.
upto 2400 W.
upto 2400 W.
upto 500 W.
68 x 68 x 122 mm
L N LS
L
N
180º
Digital Time Switches
Digital Timers Switch TR 610 Top / TP 612 Top/TR 611 Top
®TR 622 top TERMINA
By means of text-oriented operator guidance youare escorted step by step through the entireprogramming.
Day/Week Program
Operator guidance by an integrated LCDdisplay
Programming is shown graphically by ameans of a bar chart on the LCD display
Preset ex-works-time (CET) and automaticsummer/winter time changeover
Summer/Winter time changeover can bealternatively switched off or randomlyprogrammed (GB, USA changeover normselectable)
High number of memory locations
Guided copying of the switching times to otherdays of the week (random block formation)
Sorting of the switching times in memory bythe day of the week
Switching preselection
Permanent switching
Lithium battery and EEPROM
2 channels with 42 memory locations
Holiday switching, random function and pulseprogram separate for each channel.
Cycle program for channel 1.
Function :
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Technical specifications :
Rated voltage :
Frequency :
Own consumption :
Contact :
Contact material :
Switching power :
Incandescent lamp load :
Halogen lamp load :
Fluorescent lamps :
Compact fluorescent lamps :
Timing basis :
Working precision :
Shortest switching time :
Switching precision :
Display :
Operating control elements :
Power reserve :
Permissible ambient temperature :
Enclosure and insulating material :
Protection class :
Degree of protection :
Test approval :
Weight : g
230-240V~+6%-10%
50-60Hz
max. 6 VA
zero-potential, break gap less than 3 mm ( )
Ag Sn O
16A, 250V~, cos =1; 10A, 250V~, cos =0.6.
2300W
2300W
non compensated, series comp. 1000W,
parallel comp. 400 W (42 f)
9x7 W, 7x11W, 7x15w, 7x20W, 7x23W
quartz
<± 1 sec./day at 20ºC
1 minute (pulse/cycle 1 sec.)
exact to the second
LCD display with text line
4 touch keys and 1 reset key
approx. 4 years with display with full controllability(temp. 20ºC) by means of an environmentally friendly lithium battery
-10ºC...+50ºC
high-temperature resistant,self-extinguishing thermoplastics
II in compliance with EN60730-1 if installed asdirected
IP 20 in compliance with EN 60 529
appox. 170
�
� �
�
2
Design :
�
�
�
�
�
Standard enclosure 45 x 35 60 (mm)
Quick fastening facility for 35 mm DIN rail (EN 50 022)
Built-on installation with an additional terminal cover which can befitted with a leadable seal
Switch panel installation complete with installation kit No.9070001
Captive hinged cover which can be fitted with a leadable seal.
TR 610 Top
TR 608 Top
Digital Time Switches
Type Program Memory Power reserve Programmable LCD Switch Rated Current Ordering No.Location (Lithium) every... backlit Contacts at 259V~
TR 610 top
TR 612 top
TR 611 top
TR 622 top
TR 608 top 24h 28 3 years 1 min - 1 changeover 16(6)A T60800021 channel 7d
24h 28 10 years 1min. - 1 changeover 16(10)A T61000021 channel 7 days Switch
24h 42 years 1 min. - 2 changeover 16(10)A 61200022 channel 7 days switches
42 years 1 min. yes 1 changeover 16(10)A 61100021 channel switch
42 years 1 min. yes 2 changeover 16(10)A 62200022 channels switches
Terminal cover for built-on installation, can be fitted with a leaded seal. 9070064
switch
10 T
10 T
10 T
24h/7 days
random
switching,
holiday
program,
pulse and
cycle
program
Overview of the menu levels
TR 611/622 top
TR 610/612 top
* only TR 611/622 top
* only TR 622 top
Analog Time Switches
Technical data :
Nominal voltage :
Frequency :
Power consumption :
Power reserve :
Contact :
Gap :
Contact material :
Resistive switching capacity :
Inductive switching capacity :
Incandescent lamp load :
Halogen lamp load :
Uncorrected fluorescent lamp :
Series corrected fluorescent lamps :
Parallel-corrected fluorescent lamps :
Lead-lag (duo) fluorescent lamps :
Uncorrected mercury discharge lamp :
Uncorrected sodium discharge lamp :
Compact fluorescent lamps :
Time based on :
Time accuracy :
Shortest switching time :
Switching accuracy :
Display :
Control elements :
Permitted ambient temperature :
Protection rating :
Protection class :
Weight :
230-240V, +10%/-15%
50-60Hz
max, 6VA
approx. 10 years at full operability (temp. 20ºC)through pro-environmental lithium cell
Floating changeover contact
less than 3 mm ( )
Ag Sn O2
16A, 250V, cos =1
10A, 250V, cos =0.6
2300 W
2300 W
1000VA
1000VA
400VA(42 f)
1000VA
4 x 125W, 2x250W, 1 x400W, 1x700W
2x250W, 1 x 400 W
(Capacitive ballast) 1000 VA,(Electronic ballast) 9 x 7W, 7X11W, 7x15W, 7x20W, 7x23W
Quartz
<± 1s/day at 20ºC
1 minute
to the second
LCD with text line
4 touch control key s and 1 reset key
-10ºC...+50ºC
IP 20 to En 60529
II to EN 60730-1 for designated installation
approx. 170g
�
�
�
�
Parallel-corrected mercury discharge lamp :
Parallel compensated sodium discharge lamp :
6x50W (7 f),
4x125W (10 f), 2x 250W (18 f), 1x400W (25 f), 1x700 W (40 f).
2x250W
(20 f), 1x250W (32 f), 1x400W (45 f)
�
� � � �
� � �
SEL 170 top Selekta
Function :
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Solar 1-channel weekly clock with “top”operating philosophy, i.e. simplest possibleoperation through text-oriented programming
Precise calculation of sunrise and sunset timesthrough inputting date, time and locationcoordinates (longitude and latitude)
Alternatively, the location coordinates can bespecified via a country-specific and pre-programmed list of cities.
The switching on and off of the connectedconsumer depends on the sunrise and sunsettimes and can be offset forwards or backwardsfor fine adjustment by up to 120 minutes
Factory-set date and time
Text-based programming in 4 easy steps,supported by self-explanatory symbols.
Energy-saving night switch-off with simpleprogrammable weekly program
Semi-automatic function (e.g. light on duringevenings, night switch-off at 2300 hrs)
Guided copying of switching times to otherweekdays (block formation).
The daily switching times are graphicallyillustrated by a segment bar in the LCD
Date-controlled holiday program
Continuous Switching (continuous on orcontinuous off)
switching pre selection
An external input “S” enables the output to beswitched via a control signal (e.g. manualswitch)
In code, 10 year power reserve
Automatic summer/winter time correction, canbe disabled or freely selected (Europe, GB,USA/CAN changeover rule also selectable)
Flexible alternative to twilight switch(brightness sensor does not need to be wired)
Switching time guaranteed through EEPROM
SEL 170 Top
Sunset Sunrise
Lighting control system with SELEKTA 170 top
Lux (brightness)
Calculated time for
sunrise and/or sunset
(Astro Time)
Individually programmed
times for night switching
12.00 24.00 12.00
Night switch-off
Analog Time Switches
Design
�
�
�
�
�
�
Standard housing 45x35x60 mm to DIN 43 880
Quick fastening for 35mm profile rail (DIN EN 50 022)
Contact protection to comply with accident preventionregulation BVGA2 (VBG 4)
Top mounting with additional terminal box cover plate,sealable (No. 907 0 064)
Control panel installation with assembly kit (No. 9070001)
Captive cover flap, sealable
52.5
128
35
86
45
55
60
65.5
SELEKTA170 top-Solar Timer
The SELEKTA 170 top, Theben's 35mm wideastronomic timer is an ingeniously simple tooperate control unit based on the establishedTERMINA top operating concept. The specialfeatures of an astronomic timer are the preciselycalculated sunrise and sunset imes.
This ability to calculate switching times so preciselymakes the SELEKTA 170 top the ideal solution forilluminating roads, squares, courtyard approahces,display windows and corporate logos.
Type Program Power reserve Programmable Special Switching Nominal Order No.(Lithium) every... Function Contacts Voltage
at 250 V~
SEL170 top Astro program 10 Years 1 minute Local 1 changeover 16(10)A T1700002Weekly program database switch
Terminal box cover plate for top mounting, sealable
SEL173 DCF Astronomical year 1.5 years 1 minute Holiday or weekend 2 changeover 16(10)A T173001programm, 24h/7 days/years switching channel switch (without antenna
and power unit)
Antenna for DCF77 radio signal, makes DCF77 time synchronisation possible. Power supply is integrated in the device. T9070243
Programming set OBELISK (chip card, intermediate plug for PC interface, Software) T9070230
OBELISK memory board (separately) T9070165
change
Twilight Switches LUNA
®LU Star Series LUNA
Functions :
�
�
�
�
�
�
�
Twilight switch in a modern, innovative design
Integral light sensor with a very large light-entry
angle (approx. 180º) and specially formed lens
Immediate LED display of switching status
Test button for checking the installation,
independent of brightness setting (except
LUNA 126 star)
High quality relay ensures safe, secure
switching of lamp loads.
Variable ON/OFF delay settings of approx. 2-
100s, LUNA 129 star-time: 0-180s, LUNA
126 star: 40s fixed setting
Infinitely variable brightness range of approx 2-
2000 lux (model dependent). Preset
brightness value of approx. 15 lux as delivered
(LUNA 127 star and LUNA 129 star-time)
® ®
®
® ®
Technical Data :
Nominal voltage :
Frequency :
Power consumption :
Contact :
Contact material :
Switching capacity :
230~, ±10%
50Hz
Approx. 3.5 VA, 2 VA(LUNA 129)
not floating, gap less than 3 mm ( )
Ag Sn O2
16A/230V~, cos =1,
LUNA 126 star :
®
�
�
10A/230V~, cos =0.6
10A/230V~, cos =1
6A/230V~, cos =0.6
2300W (LUNA 126 star : 1000W)
2300W (LUNA 126 star : 1000W)
Uncorrected/series-corrected : 2300VA
(LUNA 126 star: 1000VA)
Parallel-corrected : 400 VA(42 f)
(LUNA 126 star; 120 VA(18 f)
Lead-lag circuit (duo) : 1200VA
(LUNA 126 star: 400VA)
Uncorrected/series-corrected : 1000VA
Parallel-corrected : 250VA(40 f)
(LUNA 126 star: use contactor)
Uncorrected/series-corrected: 1000VA
Parallel-corected : 250VA(37 f)
(LUNA 126 star: use contactor)
(Capacitive ballast) 1500 VA
(Electronic ballast) 9 x 7 w, 7x11w, 7x15w, 7x20w, 7x23w
(LUNA 126 star: (capacitive ballast) 400 VA
(Electronic ballast) 4x7W, 3x11W, 3x15W, 3x20W, 3x23W)
depends on model, see table
depends on model, see table
-35ºC to +55ºC
II, when installed in accordance with EN
60669-2-1 and EN 60669-2-2
IP 55 (in accordance with EN 60529), with
bottom connection
�
�
�
�
�
�
�
®
®
®
®
®
®
®
®
®
Glow lamp load :
Halogen lamp load :
Fluorescent lamps :
Mercury vapor lamps :
Sodium vapor lamps :
Compact flourescent lamps :
Light intensity setting :
Switch delay time :
Permissible ambient temperature :
Protection class:
Degree of protection :
Twilight Switches LUNA
85
11
8.4
49.4
Type Brightness Installation Switching delay Switching Nominal
at230 v~
LUNA® 126 star 5-200 Lux infinitely Wall mount or approx. 40 s (fixed) 1 Working contact 10 (6)A T126 0 700adjustable (linear) mast mount
LUNA 127 star 2-200 Lux infinitely Wall mount or 2-100 s 1 Working contact 16 (10) A 127 0 700adjustable (linear) mast mount infinitely adjustable
Order No.range ON/OFF contacts Current
® T
LUNA® 128 star 2-2000 Lux infinitely Wall mount or 2-100 s 1 Working contact 16 (10) A T128 0 700adjustable (logarithmisch) mast mount infinitely adjustable
LUNA® 129 star 2-200 Lux infinitely Wall mount or 0-10 min Working contact 16 (10) A T129 0 700star-time digital adjustable mast mount digital adjustable
Design
�
�
�
�
�
�
�
�
�
Generous terminal space for connecting and extending
wiring as needed
5 connecting terminals including an extra (PE) terminal
(except LUNA® 126 star)
Compact and unobtrusive housing for exterior installation
Splash-proof housing (IP 55)
Mast installation possible with standard tubing clamp (no
included)
Cables can be connected at the bottom or back of device
housing (2cables possible)
Quick-clamping screws for securing the hinged housing
cover
4mm2 connection cross section
Housing colour: white
Twilight Switches LUNA
Type Brightness Adjustment Sensor Switching delay Switching Nominal Order No.range ON/OFF contacts current
at 250V~
LUNA 110 2-200 Lux 1 brightness Surface-mounted 40/40s 1 changeover 10 (6) Arange light sensor (IP 54) switch
with screw terminals
LUNA 110 2-200 Lux 1 brightness Built-in light sensor 40/40s 1 changeover 10 (6) Arange (IP 65) with 1.5 m cable switch
Terminal cover for surface mounting LUNA 110, tamper proofing
LUNA 112 2-2000 Lux 2 brightness Surface-mounted 80/80s 1 changeover 10 (6) Aranges light sensor (IP-54) switch
with screw terminals
LUNA 112 2-2000 Lux 2 brightness Built-in light sensor 80/80s 1 changeover 10 (6) Aranges with 1.5m cable switch
Terminal cover for surface mounting LUNA 112, plombierbar
LUNA 113 2-7500 Lux 2 brightness Surface-mounted 40/40s 2 changeover 10 (6) Aranges (IP-54) switch2 channels with screw terminals max.
10 devices attachable
Terminal cover for surface mounting LUNA 113.Built-in light sensor, connection cable 1.5m, Degree of protection IP 65 (spare part), (except LUNA 113)Surface-mounted light sensor with fastening square and screw terminals, (except LUNA 113)Surface-mounted light sensor with fastening square and screw terminals, (only for LUNA 113)
(IP 54)
light sensor
®
®
LU 110 Luna
LU 112 Luna
Twilight switch for distribution panel installation
with separate surface-mounted or built-in light
sensor. Switching brightness can be adjusted
continuously between approx. 2-200 lux with the
adjusting screw immediate indication of the
switching status by LED Approx.40 s switch-
ON/swiitch-OFFdelay in order to avoid switching
errors owing to lightning flashes or car headlamps
etc.
Twilight switch for distribution panel
installation with separate light sensor as
above, but:
Control unit with range selector switch for 2
brightness
ranges:
Range 1: approx. 2-35 lux
Range 2: approx. 35-2000 lux
Approx. 40/80s switch-ON/switch-OFF delay
in order to avoid switching errors owing to
lightning flashes or car headlamps etc.
�
�
Technical data:
Nominal voltage:
Mains frequency:
Power consumption:
Contact:
Contact:
Switching capacity :
incandescent lamp load:
Halogen lamps:
Fluorescent lamp:
High-pressure discharge lamps :
Brightness range :
Switching delay (ON/OFF) :
Switching status indication :
Connection cable for light sensor :
Permissible ambient temperature :
Protection class :
Degree of protection :
Test approvals :
230 V~, ±10 %
45-60 Hz
approx. 2.2 VA
LU 113 approx. 2.7 VA
floating, gap less than 3 mm ( )
material:Ag Sn O2
10A/250 v~, cos = 1
6A/250 v~, cos = 0.6
1000 w
1000 W (230 V~)
uncompensated/series compensated 800 W
parallel compensated 200 W
lead-lag circuit (duo) 800 W
use power contactor
2...7500 lux on LU 113
2...2000 lux, 2...200 lux on LU 110
Approx. 80s, Approx. 40s on LU 110
and LU 113
LED (no delay)
2-core cable max. 100m
control unit : -10ºC...+50ºClight sensor : -40ºC...+70ºC
II in accordance with EN 60335-1 if installed as
directed
in accordance with EN 60 529
Control unit : IP 20
Surface-mounted light sensor : IP 54 with cable connection at
bottom built-in light sensor : IP 65
national and international depending on devicetype
�
�
�
Communication in all directions
Din Rail Programable Logic Controller
PHARAO-II 14 (AC)
Common Functions
�
�
�
�
�
�
�
�
�
�
�
Programmable controller for commercial andindustrial use.
34 pre-programmed function blocks withspecial control functions that can be used upto 200 times
Direct programming of even complexBoolean functions in one function module
Programming, editing and modifying on theunit itself via 8 keys without interface cable
Backlit LCD with operator guidance in 4x12character text
Input and output switching status display
Process variable display (MMI function)
Assignment of programmed functions on frontkey
Internal EEPROM memory for max. 200function blocks (5,000 bytes)
Optional plug-in EEPROM for programt rans fe r o r dua l p rog ramming o finternal/plugged-in EEPROM
3-level password protection
Din Rail ProgramProgrammableLogic Controller
Type Outputs Rated Voltage Range Inputs Input Frequency Order No.
PARAO 6 (AC) 2 relays (NO Contact) 100-240 VAC, +10%/-15%, 4 digital inputs max. 5 Hz T 5750006a 8A/250V~ 50-60 Hz 100-240 VAC (0.24 mA/240 VAC)
PHARAO 10 (AC) 4 relay (NO contact) 100-240VAC, +10%/-15%, 6 digital inputs max. 5 Hz T5750010a 8/A250V~ 50-60Hz 100-240 VAC (0.24 mA/240VAC)
PHARAO 11 (DC) 4 relays (NO contact) 24 V DC, +20%/-15% 6 analogue/digital eligible inputs max. 20Hz T5759011a 8A/250 V~ 0-10 V DC or 24V DC, sink/source
PHARAO 12 (DC) 4 transistor outputs 24 V DC, +20%/-15% 6 analogue eligible inputs max. 20 HZ T 5759012a 1A/24 DC 0-10 V DC order 24 V DC, sink/source
PHARAO 20 (AC) 8 relays (NO Contact) 100-240VAD, +10%/-15% 12 digital inputs max. 5 Hz T 5750020a 8A/250V~ 50-60Hz 100V-240VAC (0.24mA/240VAC)
PHARAO 21 (DC) 8 relays ( Contact) 24V DC, +20%/-15% 12 inputs : 4 digital inputs, 20 1a 8A/250V~
PHARAO 22 (DC) 8 transistor outputs 12 20 2
PHARAO-II 14 (AC) 6 relays (NO contact) 100-240 VAC, + 10%/-15%, 8 digital inputs 14a 8A/250V~ 50-60 Hz
PHARAO-II 15 (DC) 6 relays (NO contact) 8 analogue/digital eligible inputs 15a 8A/250V~
PHARAO-II 24 (AC) 4 relays a 8A/250V~ 100-240 VAC, +10%/-15% 15 digital inputs 245 relays a 2A/250V~ 50-60Hz
PHARAO-II 25 (DC) 4 relays a 8A/250V~ 24 V DC, +20%/-15% 15 inputs, 8 of them 55 relays a 2A/250V~ analogue/digital eligible inputs
PHARAO-II 220-240VAC 4 digital inputs 100Upgrade 4 ED (AC) 50-60Hz
PHARAO-II 4 digital inputs 5 101Upgrade 4EDA(DC)
PHARAO-II 220-240VAC 4 digital outputs 2x1 kHz 102Upgrade 4AR (AC) 50-60Hz
Power unit 24VDC, 36W, 4 TE
Luna 131 DDC combination sensor, temperature and brightness sensor for analogue inputs on PHARAO units, 0-10 VDC
Pharao programing software, CD for windows 95/98/NT/2000/ME/XP, software for Pharao and Pharao-II generation
Programming cable, PC/PHARAO
PharaO-II GSM cable T9070329
Plug-in EEPROM, memory module T9070253
Plugs-in PHARAO-II EEPROM T9070328
Front panel installation kit T9070001
NO max. Hz T 5750028 inputs alternatively
analogue/digital,0-10V DC or 24V DC, sink/source
24V DC, +20%/-15% inputs : 4 digital inputs, max. Hz T 575002a 1A/24 DC 8 inputs alternatively
analogue/digital,0-10V DC or 24V DC, sink/source
max. 20 Hz T 57500
24V DC, +20%/-15% max. 20 Hz T 57500
max. 20 Hz T 57500
max. 20 Hz T 575002
max. 20 Hz T 5750
24V DC, +20%/-15% max. Hz T 57500
T 5750
T9079330
T1319700
T9070251
T9070252
�
�
�
�
�
�
Realtime year clock with 1,000 switching times
Graphical programming software for windows95/98/NT/2000/ME/XP with detailed online helpdocumentation
Programming of the function blocks via "drag and drop"
Online/offline program simulation on screen
Remote control/remote monitoring possible via modem orGSM modem
Transmission of SMS, email or fax
Communication in all directions
Cost efficient remote control and monitoring.
Because PHARAO software 2.0 contains the
entire set of communication tools, the PC
requires only a modem to enable remote
configuration, monitoring and
programming.
Error messages or threshold values
in the text can be sent by SMS from
controller to mobile telephone.
Error messages or
threshold values
in te text can be sent
from controller to
Fax Machine.
Analogue modem
GSM
Modem
Time Switch & DevicesSelection Table for Digital and Analog time switches
DIG
ITA
LProgram Contacts Contacts Minimum Nominal Power Distributor Wall Switch Flush Type
distance trippable switching current at reserve panel mounting panel mounting
< 3mm ( ) every.. time 250V~ approx. installation install�
1s 1s 16A 10 years – – TR 611 top DCF
1s 1s 16A 8 years – – TR651 S
1min 1min 16A 3 years – – TR 608 top
1min 1min 16A 10 years – – TR 610 top
1min 1min 16A 10 years – – TR 635 top
1s 1s 16A 10 years – – TR 622 top
1s 1s 16A 8 years – – TR 652 S
1min 1min 16A 10 years – – TR 612 top
1min 1min 6A 10 years – – TR 636 top
1 min 1min 6A 10 years – – TR 685/2 top
1s 1s 10A 8 years _ _ TR 653 S
1s 1s 10A 10 years – – – TR030 Top
1s 1s 16A 10 years – – TR 611 top
1s 1s 16A 1.5 years – – TR 641 S
1s 1s 16A 1.5 years – – TR 641 S DCF
1s 1s 16A 1.5 years – – TR 642 S
1s 1s 16A 1.5 years – – TR 642 S DCF
1s 1s 16A 1.5 years – – TR 644 S
1s 1s 16A 1.5 years – – TR 644 S DCF
�
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
Program Contacts Contacts Minimum Nominal Power Distributor Wall Switch Typedistance trippable switching current at reserve panel mounting panel
< 3mm ( ) every.. time 250V~ approx. installation install�
18.5 s 1.25 min 10 A – TM 179 h
37.5 s 2 min 10 A – TM 178 h
75 s 75 s 10 A – TM 171 h
15 min 15 min 16 A 3 days – SYN 160 a
15 min 15 min 16 A – SUL 180 a
15 min 15 min 10 A – SYN 169 s
15 min 15 min 10 A 3 days – SUL 189 s
15 min 30 min 16 A – SYN 168 h
5 min 20 min 6 A 150 h – SUL 285/1 T
15 min 30 min 10 A – SYN 168 g
15 min 30 min 10 A 3 days – SUl 188 g
5 min 20 min 6 A 150h – SUl 285/2 T
5/30 min 20 min/2h 10 A – SYN 269 h
5/30 min 20 min/2h 10 A 3 days – SUL 289 h
5 min 20 min 6 A 150h – – SUL 285 /1 TW
5/30 min 20 min/2h 6 A – SYN 269 g
5/30 min 20 min/2h 6 A 150h – – SUL 285/2 TW
15 min 30 min 10 A 3 days – SUL 189 hw
15 min 45 min 10 A – SYN 168 hw
–
15 min 30 min 16 A 3 days – SUL 188 h
30 min 30 min 16 A – SYN 161 h
30 min 30 min 16 A 3 days – SUL 181 h
2 h 2 h 16 A 3 days – MEM 190 a
1 h 3 h 16 A 3 days – MEM 198 h
5/30 min 20 min/2h 6 A 3 days – SUL 289 g
15 min 45 min 10 A 3 days – SUL 188 hw
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
�
� �
� �
�
� �
� �
� �
24h+7 days
YearProgram
60 min
24h
7 days
24hor7 daysadjustment
24 h + 2 dayssame dailyprogram oncertainweekend
� especially suitable –suitable to a limited extent
AN
AL
OG