tnb presentation to mpia members-5th june2014.pdf
TRANSCRIPT
![Page 1: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/1.jpg)
PRIMARY DRIVER OF GREEN ENERGY IN MALAYSIA
Presented bySustainable Energy Development Section
Customer Service DepartmentDistribution Division, TNB
![Page 2: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/2.jpg)
![Page 3: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/3.jpg)
GENERAL INFORMATION OF RENEWABLE ENERGY
DEVELOPMENT IN PENINSULAR MALAYSIA
![Page 4: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/4.jpg)
Commercial
Industrial
Residential
Kumpulan Wang Tenaga Boleh Baharu RM 3.39
(Except Resindential< 300kWh)
![Page 5: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/5.jpg)
![Page 6: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/6.jpg)
Technology FiT Duration Range of FiTRates (RM/kWh)
Annual Degression
Biomass (palm oil waste, agro based)
16 0.27 – 0.35 0.5%
Biogas (palm oil waste, agro based,farming)
16 0.28 – 0.35 0.5%
Mini hydro 21 0.23 – 0.24 0%
Solar PV & PP 21 0.85 – 1.78 8%
Solid Waste & Sewage 16 0.37 – 0.45 1.8%
![Page 7: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/7.jpg)
![Page 8: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/8.jpg)
TNB’S BASIC FIT PROCESSES& REQUIREMENTS
![Page 9: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/9.jpg)
9
RE DEVELOPER / FIAH TNBSEDA MALAYSIASTEPS
![Page 10: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/10.jpg)
FiAH downloads REPPA document
from SEDA website
FiAH submits complete REPPA documents with
attachments to TNB
SEDS submits REPPA to Legal Service Department for
signing off
TNB authorized signatory signs
REPPA
TNB returns the signed REPPA to FiAH
for stamping
FiAH submits stamped REPPA
each to TNB & SEDA
REPPA METER NC T&C PAYMENT
![Page 11: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/11.jpg)
REPPA METER NC T&C PAYMENT
![Page 12: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/12.jpg)
REPPA METER NC T&C PAYMENT
Documents required during submission of
REPPA
REPPA form- A contract for
energy purchase
under RE Act 2011
RE Application form
- To create new account for
FiAH
Vendor Master Data Maintenance
Form- To create Vendor No. for payment
Customer Master Data
Form- To create RJO
for meter purchase
Receivable from Monday to Wednesday every week (9.00am till
12.00 noon only)
![Page 13: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/13.jpg)
PREPARATION OF REPPA:1. Download the standard REPPA form from SEDA website.2. Fill in (in typing mode & not hand writing) for page 1, page for Para 18 (Notices) and signatures page only.
The other pages leave as it is and no amendment is allowed at all. Please ensure the information given are checked and correct.
3. FiAH shall put his/her signature on each page of REPPA form except the signing page (last page of form)4. Each document i.e FiT Approval certificate must be certified true copy by Commissioner of Oath.5. FiAH and his/her witness shall put their signatures on the signing page (last page of REPPA form)6. Make three (3) copies of REPPA form and put them in 3 separate Management File.7. Each File should has separator (index divider) for each document . The documents are:-
a) REPPA formb) Appendixes
i) For generation capacity <= 425kW (low voltage connection), use Appendix Aii) For generation > 425kW up to and including 1MW, use Appendix Biii) For generation capacity > 1MW, use Appendix A, B, C, D and E
Reminder:• If FiAH/Service Provider realize any errors occurred on the Feed-in Approval certificate i.e premise address, FiAH’s name, IC, ROC, FiAH/Service Provider shall refers that matter to SEDA Malaysia for correction & approval or gets new certificate.• Please refer to the existing electricity bill for the premise if any to ensure the address is correct and similar. This is crucial for TNB to create new account for FiAH in TNB’s billing system later on. Any inconsistency of address and/or any other info will caused delay in creating new account.
REPPA METER NC T&C PAYMENT
![Page 14: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/14.jpg)
< FiAH initial >
< FiAH initial >
Keep blank for TNB
Name of Service ProviderI/C No:
Name of FiAHI/C No:
![Page 15: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/15.jpg)
REPPA form
FiA certificate (certified true copy)
Appendix
Management File (with separator)
SAMPLE ONLY
![Page 16: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/16.jpg)
Individual Non-individual
• FiA certificate• A copy of IC• A copy of Q form (EC)• A copy of electricity bill• A copy of CCC approval• A copy of undertaking or
approval letter by SEDA Malaysia for case of error in FiA certificate
Note:All this documents do not require certified true copy
• FiA certificate• A copy of Borang 44• A copy of Borang 24• A copy of Borang 49• A copy of Q form (EC)• A copy of electricity bill• A copy of CCC approval report
(12kW up to & including 425kW)• A copy of PSS approval and its
report (> 425kW)• A copy of undertaking or approval
letter by SEDA Malaysia for case of error in FiA certificate
Note:All this documents do not require certified true copy except for Borang24 and Borang 49.
NEW ACCOUNT FORM:Complete the RE Application Form and submit to TNB with all supported documents as shown below:-
REPPA METER NC T&C PAYMENT
![Page 17: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/17.jpg)
VENDOR REGISTRATION FORM:Complete the Vendor Master Data Maintenance Form and submit to TNB with all supported documents as shown below:-
REPPA METER NC T&C PAYMENT
Individual Non-Individual
• A copy of IC• A copy of Bank
statement
Note:Bank statement shall clearly state the owner name and IC.
• A copy of Borang 9 (SSM)
• A copy of Borang 13 (for case of company name changed)
• A copy of Bank statement
Note:Bank statement shall clearly state the company name and ROC.
All documents are to be submitted in two (2) copies
![Page 18: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/18.jpg)
REPPA METER NC T&C PAYMENT
METER PURCHASE FORMS:1. Customer Master
Data Form2. Meter Purchase
Form3. Attached a copy of
FiA certificate (first page only)
4. Borang MaklumatAwal (BMA) –Large Power Metering
![Page 19: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/19.jpg)
REPPA METER NC T&C PAYMENT
![Page 20: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/20.jpg)
REPPA METER NC T&C PAYMENT
![Page 21: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/21.jpg)
REPPA METER NC T&C PAYMENT
![Page 22: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/22.jpg)
![Page 23: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/23.jpg)
Conditions For Connection to Grid TNB-
1. FiAH & TNB have entered into a RE Power Purchase Agreement (REPPA)
2. REPPA has been registered by SEDA
3. FiAH submit written application for connection to TNB
4. The connection has been made at the location approved
5. Method of connection approved.
6. The connection is carried out by the distribution licensee
REPPA METER NC T&C PAYMENT
![Page 24: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/24.jpg)
Time Frame For Connection by TNB- Subject to the compliance and completeness of installation at site by Competent Person
Low Voltage:
Ø Within 30 days from the application received for T&C by Sustainable Energy Section
Medium Voltage:
Ø Within 60 days from the application received (Initial Operation Date) by Sustainable Energy Section
Testing & Commissioning (T&C)REPPA METER NC T&C PAYMENT
![Page 25: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/25.jpg)
• Cut-out fuse – existing at site, old model where there are two cable slots
• Junction box – typically for new connection at 5 foot mains• Black box – for overhead system or transition between
overhead and underground systems. • Feeder pillar – for underground system. Either existing or
new installation.• FiAH to provide Information Signage at Connection Point
and Grid source (substation)
25
Testing & Commissioning (T&C)
Available Low Voltage Connection Points at TNB Grid SystemREPPA METER NC T&C PAYMENT
![Page 26: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/26.jpg)
26
Testing & Commissioning (T&C)
Available Low Voltage Connection Points at TNB Grid SystemREPPA METER NC T&C PAYMENT
FiAH
RE PLANT
Solar PV panels
Inverter
Export Meter
0.4 kV
0.4 kVCapacity <=60kWp
=~
Meter Panel
Substation0.4 kV
AB
TNB Load
Connection Point
Existing service cable
FiAH
RE PLANT
Solar PV panels
Inverter
Export Meter
0.4 kV
0.4 kVCapacity >60kWp
=~
Load
Meter KioskAB
TNB Load
Connection point
Existing service cable
Substation0.4 kV
![Page 27: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/27.jpg)
27
REPPA METER NC T&C PAYMENT
![Page 28: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/28.jpg)
28
REPPA METER NC T&C PAYMENT
Action by FiAH:1. Ensure all requirements stated in the T&C
checklist are fulfilled for meter purchase and T&C.
2. Make a copy of each document for T&C (hardcopy) except the REPPA.
3. Burn all the documents in a compact disc (CD) as pdf file inclusive of stamped REPPA.
4. Submit the documents and a CD to SEDS TNB.
5. Bring along the T&C form during T&C, get the signature of TNB local station after T&C successfully done.
6. Forward the T&C form either by hand or email to [email protected] for SEDS TNB acknowledgement.
7. Received complete T&C form and upload to eFiT SEDA Malaysia.
![Page 29: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/29.jpg)
29
REPPA METER NC T&C PAYMENT
![Page 30: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/30.jpg)
30
Solar PV
REPPA METER NC T&C PAYMENT
![Page 31: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/31.jpg)
31
REPPA METER NC T&C PAYMENT
Solar PV
![Page 32: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/32.jpg)
32TO MSB Consumer
REPPA METER NC T&C PAYMENT
Solar PV
![Page 33: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/33.jpg)
33
REPPA METER NC T&C PAYMENT
![Page 34: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/34.jpg)
34
REPPA METER NC T&C PAYMENT
![Page 35: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/35.jpg)
VERIFICATION PROCESS
582kWh/(5.5kW*28 days)= 3.78 hour/day (ok)
REPPA METER NC T&C PAYMENT
![Page 36: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/36.jpg)
36
REPPA METER NC T&C PAYMENT
Available
![Page 37: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/37.jpg)
Nos Officer in-charge Email / Contact No 1 Dafit Duli Hera [email protected]
019-664 34562 Shyamini A/P Kanagaratnam [email protected] 012-
925 4090Selventhiran A/L Jai Komar [email protected]
03-7967 9000 ext 1349
Nos Officer in-charge Accounts Email / Contact No 1 Norhazila bt Mohammad Hussin All RE accounts [email protected]
019-357 7421 • Azrin Hakimi bin Jaafar Kedah & Penang [email protected]
03-7967 9000 ext 1802• Norlinda bt Faisal Rizal Selangor (except PJ & Klang) [email protected]
03-7967 9000 ext 1802• Muhamad Faidhi bin Ibrahim Perlis, Perak, Kelantan, Terengganu,
[email protected] 9000
• Natasha bt Mohamad Jumli PJ & Klang [email protected] 9000 ext 1349
2 Noraina bt Tahir Kuala Lumpur & Putrajaya [email protected] 9738
• Suhaida bt Mohamed Supian Negeri Sembilan, Melaka & Johor [email protected] 9088
Nos Officer in-charge Email / Contact No 1 Siti Rohayu Md Ali [email protected]
019-330 32792 Maisarah Che Ros [email protected]
03-7967 90003 Vellasamy Karupiah [email protected]
03-7967 9000 ext 13494 Norhazila Mohd Yunus [email protected]
03-7967 9000
![Page 38: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/38.jpg)
![Page 39: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/39.jpg)
www.e-Services.tnb.com.my-View & print the payment advice
- Notification to FiAH when the payment advice is verified
Guidelines for renewable energy processes & procedures practiced by TNB
![Page 40: TNB Presentation to MPIA Members-5th June2014.pdf](https://reader033.vdocument.in/reader033/viewer/2022052206/586a1bdc1a28abb7788b6694/html5/thumbnails/40.jpg)
THANK YOU