tom acker, ph.d. cherise john, ms candidate department of mechanical engineering mehrdad khatibi...

Download Tom Acker, Ph.D. Cherise John, MS Candidate Department of Mechanical Engineering Mehrdad Khatibi Tribal Clean Energy Resource Center Institute for Tribal

If you can't read please download the document

Upload: merry-underwood

Post on 17-Dec-2015

222 views

Category:

Documents


4 download

TRANSCRIPT

  • Slide 1
  • Tom Acker, Ph.D. Cherise John, MS Candidate Department of Mechanical Engineering Mehrdad Khatibi Tribal Clean Energy Resource Center Institute for Tribal Environmental Professionals November 18, 2014 Flagstaff, AZ 1 JEMEZ PUEBLO SOLAR POWER PRE-FEASIBILTY STUDY
  • Slide 2
  • Sustainable Energy Solutions Project Funding US Department of Energys American Indian Research and Education Initiative (DOE- AIREI). American Indian Science and Engineering Society (AISES) American Indian Higher Education Consortium (AIHEC) 2
  • Slide 3
  • Sustainable Energy Solutions Project Partners Project partners: Pueblo of Jemez, New Mexico Northern Arizona University Southwest Indian Polytechnic Institute Advising: Sandia National Laboratory 3
  • Slide 4
  • Sustainable Energy Solutions Outline Purpose Site overview and system configurations System Advisor Model (SAM) Model inputs Results Summary 4 Fixed PV horizontal axis wn.com http://www.bluepacificsolar.com/ Fixed PV titled at latitude
  • Slide 5
  • Sustainable Energy Solutions Purpose Involve Native American students in relevant R&D-type project that could benefit a tribe Investigate potential for a utility-scale solar project on the Jemez Pueblo reservation with the intent to sell to out-of-state buyers 40 MW project size on the Holy Ghost site 5 Holy Ghost site on Jemez Reservation
  • Slide 6
  • Sustainable Energy Solutions Four Systems Considered NAU: Fixed, horizontal PV NAU: 1-axis tracking, horizontal PV NAU & SIPI: Fixed, tilted at latitude PV NAU & SIPI : CSP Solar Power Tower 6 http://rredc.nrel.gov/solar/calc ulators/pvwatts/system.html http://www.solarchoice.net.au/blog/solar-trackers/ Horizontal PV 1-axis tracker Sandia National Laboratories / PIX 00036 Solar Power Tower
  • Slide 7
  • Sustainable Energy Solutions Site with New Mexico Jemez Pueblo is located within Sandoval County, New Mexico: Elevation: 5,600 ft Climate: Dry-hot Population: 3,600 7 Google Maps, 2014.
  • Slide 8
  • Sustainable Energy Solutions High Solar Energy Potential Annual latitude tilt irradiance level of 6.4 kWh/m 2 /day 8 Source: NREL Solar Prospector, 2014 New Mexico State
  • Slide 9
  • Sustainable Energy Solutions 9 Google Maps, 2014 Credit: Mehrdad Khatibi, 2014 Looking NW at Holy Ghost Site High Solar Energy Potential
  • Slide 10
  • Sustainable Energy Solutions Transmission Grid Connection 10 5 miles to nearest grid interconnection Credit: Mehrdad Khatibi, 2014 Google Maps, 2014
  • Slide 11
  • Sustainable Energy Solutions Solar Resource: DNI, GHI, Diffuse 11
  • Slide 12
  • Sustainable Energy Solutions System Advisor Model (SAM) 12 Energy and performance model based on location, technology, system design parameters, costs, etc. SAM uses a library of cost, financial, performance, and resource models developed at NREL, Sandia, Univ. of Wisconsin, and other places. NREL SAM, Jan 2014
  • Slide 13
  • Sustainable Energy Solutions SAM PV Inputs System size: 40 MW DC PV panels: Prism Technologies 245 B (245 W panel) Inverter: Satcon Technologies 1.25 MW System location: lat 35.71 long -106.95 Holy Ghost site 13 Size of the PV array system: Strings in parallel: 7420 Number of inverters:30 PV modules in one string: 22
  • Slide 14
  • Sustainable Energy Solutions SAM Solar PV Module 14
  • Slide 15
  • Sustainable Energy Solutions SAM Solar Array Info 15
  • Slide 16
  • Sustainable Energy Solutions SAM Solar Configuration 16
  • Slide 17
  • Sustainable Energy Solutions SAM System Costs 17
  • Slide 18
  • Sustainable Energy Solutions Power Tower Specs Molten salt with 10 hours of storage Tower height 203 meters; Receiver height 20 meters 8,929 heliostats (mirrors) height, width 12.2 meters Field size 1,953 acres Installed cost: $580M ($16.7k/kW) Source: NREL
  • Slide 19
  • Sustainable Energy Solutions SAM Financial Inputs 19 PPA Price $ 0.12/kWh 20 yr loan at 7% Real discount rate 8.2% Fed Income Tax 35% Fed Investment Tax Credit 30%
  • Slide 20
  • Sustainable Energy Solutions SAM Performance Outputs 20
  • Slide 21
  • Sustainable Energy Solutions PV Monthly Energy Output 21
  • Slide 22
  • Sustainable Energy Solutions Net Present Value Results 22
  • Slide 23
  • Sustainable Energy Solutions Net Present Value Sensitivity 23 1-axis tracker
  • Slide 24
  • Sustainable Energy Solutions Summary NAU and SIPI students conducted studies Financial results look promising: PV systems NPA ranged from $16M to $34M with a PPA price of $0.12 / kWh Power tower NPV is $79M with PPA of $0.20 / kWH NPV is most sensitive to PPA price and the real discount rate Future analysis: transmission interconnect cost; optimize plant size, technology, and configuration; tune SAM inputs to Jemez project and customers 24
  • Slide 25
  • Sustainable Energy Solutions THANK YOU! Nader Vadiee, Ph.D. Jonathan West, Matthew Collins, Tomzak Billie Engineering and Engr Technology Programs Southwestern Indian Polytechnic Institute 25 Thomas L. Acker, Ph.D., Mehrdad Khatibi Cherise John, Kaelyn DeVore, Steven Tallas [email protected] [email protected] Stan Atcitty, Ph.D. [email protected] (Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin company, for the U.S. Department of Energys National Nuclear Security administration under contract DE-AC04-94AL85000.) Joshual Madalena, Governor John Galvin, Greg Kaufman, Division of Natural Resources Pueblo of Jemez
  • Slide 26
  • Appendix 26
  • Slide 27
  • Sustainable Energy Solutions References (1) National Renewable Energy Laboratory, Alliance for Sustainable Energy, LLC. Dynamic Maps, GIS Data & Analysis Tools. 3 Sept. 2013. Web. Accessed 16 Apr. 2014. (2) National Renewable Energy Laboratory, Alliance for Sustainable Energy, LLC. Solar Prospector. 16 Apr 2014. Web. Accessed 16 Apr. 2014. (3) National Renewable Energy Laboratory, Alliance for Sustainable Energy, LLC. System Advisor Model (SAM). Published by samadmin on Mon, 4 May 2010. Web. Accessed 16 Apr. 2014. (4) Turchi, C.S., and G.A. Heath, Molten Salt Power Tower Cost Model for the System Advisor Model (SAM). NREL/TP-5500-57625, Feb 2013 27
  • Slide 28
  • Sustainable Energy Solutions Definitions 28 Calculated ppa escalation (%)The PPA escalation rate is an annual escalation rate that SAM uses to calculate the PPA price in Years Two and later. LCOEThe LCOE is the total cost of installing and operating a project expressed in dollars per kilowatt-hour of electricity generated by the system over its life LCOE Nominal @ 10.9%The nominal LCOE is a current dollar value and depends on the nominal discount rate and does not depend on inflation rate. The nominal (current) dollars may be more appropriate for short-term analyses. LCOE Real @ 8.2%The real LCOE is a constant dollar, inflation-adjusted value and depends on the real discount rate. Real (constant) dollars may be appropriate for long-term analyses to account for many years of inflation over the project life Net present valueA project's net present value (NPV) is a measure of a project's economic feasibility that includes both revenue (or savings for residential and commercial projects) and cost. In general, a positive net present value indicates an economically feasible project, while a negative net present value indicates an economically infeasible project, although this may not be true for all analyses. Internal Rate of Return (%)The internal rate of return is the nominal discount rate that corresponds to a net present value of zero for projects with commercial PPA or utility financing Minimum DSCRThe minimum DSCR is the minimum debt-service coverage ratio that SAM calculates for projects with the Commercial PPA or Utility IPP financing option that you choose Capacity FactorThe capacity factor is the ratio of the system's predicted electrical output in the first year of operation to the nameplate output, which is equivalent to the quantity of energy the system would generate if it operated at its nameplate capacity for every hour of the year. For PV systems, the capacity factor is an AC-to-DC value. First year kWhac/kWdcFor PV systems, SAM reports the ratio of the system's annual AC electric output in Year one to it's nameplate DC capacity: First year kWhac/kWdc = Net Annual Energy Nameplate Capacity System performance factor (%)The system performance factor is a measure of a photovoltaic system's annual electric generation output in AC kWh compared to its nameplate rated capacity in DC kW, taking into account the solar resource at the system's location.
  • Slide 29
  • Sustainable Energy Solutions Power Tower Layout Source: NREL