tore aarsland - norsk standard changes.pdf · tore aarsland . chairman of the ... system...
TRANSCRIPT
![Page 1: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/1.jpg)
Tore Aarsland Chairman of the Editorial Revision Committee / Senior Design Engineer @ C6 Technologies
10-Jan-13
![Page 2: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/2.jpg)
![Page 3: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/3.jpg)
1. The well barrier philosophy of the standard is harmonised to NORSOK D-010. The use of the term tertiary well control is therefore discontinued.
2. The requirements of the final element of the secondary barrier has been expanded to reflect today's expectations and understanding.
![Page 4: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/4.jpg)
3. External references has been updated and the number of them reduced.
4. Test requirements for pressure control equipment is further specified.
5. Requirements for subsea operations, hose management, dropped objects and lifting operations are added.
![Page 5: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/5.jpg)
6. Mandates independent 3rd party verification of new designs, products and solutions related to the final element of the secondary barrier.
7. The structure is revised to increase readability.
![Page 6: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/6.jpg)
8. The inclusion of operational requirements have been reduced as these are not included in the scope of the standard. Some are, however, kept as they are found to be critical for a safe operation. These are never preceded by the verbal form shall.
![Page 7: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/7.jpg)
1. Scope 2. Normative and informative references 3. Terms, definitions and abbreviations 4. General requirements 5. Well control 6. Snubbing 7. Coil tubing 8. Wireline
![Page 8: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/8.jpg)
The scope of this NORSOK standard is to provide common functional requirements for well intervention equipment used on the Norwegian Continental Shelf across the different operators. Tools and equipment intended for deployment inside a well is not covered.
![Page 9: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/9.jpg)
Well intervention is the deployment of tools and equipment in a completed well. An intervention string is normally used to lower and retrieve the tools. Alternatively, the string can constitute the tool itself. Expected well pressure = reservoir pressure - minimum well fluid gradient + kill margin
![Page 10: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/10.jpg)
Wireline is intervention using a continuous string without any internal bore. Coil tubing is intervention using a continuous string with an internal bore. Snubbing is intervention using jointed pipe
![Page 11: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/11.jpg)
Equipment under the scope of this standard will by default fall into at least one of the following categories and shall satisfy the requirements of the corresponding standards: • Topside Pressure Control Equipment: ISO 10423 • Subsea Pressure Control Equipment: ISO 13628-7 • Temporarily Equipment: NORSOK Z-015 • Supporting Structures: NORSOK N-001
![Page 12: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/12.jpg)
This standard is applicable for all well intervention equipment manufactured after the 1st of January 2014. All well intervention equipment shall comply to this revision no later than the 1st of January 2018.
![Page 13: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/13.jpg)
All suppliers that design, manufacture or sell well intervention equipment shall have a quality management system based on ISO 9001 or equivalent. All new designs, products and solutions related to the final element of the secondary barrier, including the control of said device, shall be verified by an independent 3rd party.
![Page 14: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/14.jpg)
Hose assemblies should be managed, inspected and replaced according to Guidelines for the management of flexible hose assemblies. These guidelines are published by Energy Institute in the UK.
![Page 15: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/15.jpg)
Lifting equipment shall be designed according to NORSOK R-002. Lifting operations should be carried out in according to NORSOK R-003. Provisions shall be made for handling of BHAs in compliance with these lifting requirements.
![Page 16: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/16.jpg)
Well intervention equipment shall be designed according to part 2 of Handbook – Best Practice – Dropped Object Management to reduce the risk of dropped objects. These are guidelines published by Samarbeid for Sikkerhet
![Page 17: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/17.jpg)
• The required product specification level (PSL) of pressure control equipment is determined by annex A in ISO 10423.
• Rams and valves under the scope of this standard shall be tested to performance requirement 2 (PR2) according to annex F in ISO 10423.
![Page 18: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/18.jpg)
www.c6technologies.com
![Page 19: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/19.jpg)
• BOPs and safety heads having an vertical through-bore dimension equal or greater than 7 1/16" shall be designed, manufactured and tested according to ISO 13533. This replaces the above requirement to test according to annex F in ISO 10423 for such equipment.
![Page 20: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/20.jpg)
• Be able to shear the intervention string in use with less than 90% of the max hydraulic working pressure, demonstrated by a shear test according to ISO 13533 Annex C.2.3
• Independent HPU (not shared with the primary barrier)
• SIL 2 (same as for a drilling BOP)
![Page 21: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/21.jpg)
• All connections forming the secondary barrier envelope shall have metal-to-metal seals
• Two control panels, one should be located in the control cabin
• HPU located in a non-hazardous area outside the wellhead area
![Page 22: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/22.jpg)
• There shall be at least two independent technical measures to prohibit the accumulation of multiple strands of severed intervention string through the secondary well barrier. This requirement is not applicable for intervention strings without any compressive strength.
![Page 23: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/23.jpg)
A snubbing operation on the Norwegian Continental Shelf will most often be rig assisted due to the requirement for a remotely operated pipe handling system. This standard does not intend to introduce additional requirements for permanently installed drilling equipment which is covered by NORSOK D-001.
![Page 24: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/24.jpg)
The requirement for dual redundant stationary snub slips have been removed. This is not used in recent operations because the safety interlock system implemented on all rigs is sufficient to ensure the retention of the string.
![Page 25: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/25.jpg)
The possibility of using old, conventional tongs has been removed. Tongs shall be remote operated.
10-Jan-13 www.c6technologies.com 25
![Page 26: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/26.jpg)
• Control of the primary well barrier from the cabin added
• Increased required rate of grease injection, from 0.25 l/min to 0.75 l/min.
• Updated requirements for speed and tension
10-Jan-13 www.c6technologies.com 26
![Page 27: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/27.jpg)
Wire size
Creep Speed
(outer diameter)
[m/min]
Full Speed
(inner diameter)
[m/min]
Max pull
(outer diameter)
[kg]
Acceleration
[m/s2]
< 3/16” ≤5 ≥150 ≥1 500 2
≥ 3/16"
≤ 7/32" ≤2 ≥80 ≥3 000 1
> 7/32” ≤0.5 ≥60 ≥5 000 0.5
![Page 28: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/28.jpg)
• 9: Documentation
• Annex A: Data Sheet Snubbing Equipment
• Annex B: Safety Head Requirements
• Annex C: Snubbing and Coil Tubing Rig-Up
• Annex D: Wireline Rig-Up
![Page 29: Tore Aarsland - Norsk Standard changes.pdf · Tore Aarsland . Chairman of the ... system implemented on all rigs is sufficient to ensure the ... Data Sheet Snubbing Equipment •](https://reader033.vdocument.in/reader033/viewer/2022052710/5ab2adda7f8b9a1d168dbb72/html5/thumbnails/29.jpg)
• Provisions shall be made for handling all equipment and BHAs in compliance with lifting requirements
• 3rd party verification of new designs, products and solutions related to the final element of the secondary barrier
• Two control panels for the final element of the secondary barrier, one of the shall be installed in the control cabin