DU-GEM-0020-02 Rev B 12/9/14 Page 1 of 4 gcx.com | (800) 228-2555 | +1 (707) 773-1100 | Fax +1 (707) 773-1180 GCX European Office |+31(0) 88 627 2600 | Fax +31 (0) 88 627 2609 GCX Taiwan | (886) 2 2298 2842 |Fax (886) 2 8990 3052 Installation Guide Tower Mount Bracket for DINAMAP® Mobility Workstation Use to mount 75x75mm mounting pattern devices Capsule Neuron with Mini Dock Capsule Neuron 2 (1) 1/8” Hex Wrench (1) 4mm Hex Wrench (2) M6 x 20 BHSCS (4) M4 x 14 PHMS (4) M4 x 10 PHMS

Upload: others

Post on 28-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

DU-GEM-0020-02 Rev B 12/9/14 Page 1 of 4 gcx.com | (800) 228-2555 | +1 (707) 773-1100 | Fax +1 (707) 773-1180 GCX European Office |+31(0) 88 627 2600 | Fax +31 (0) 88 627 2609 GCX Taiwan | (886) 2 2298 2842 |Fax (886) 2 8990 3052

Installation Guide

Tower Mount Bracket for DINAMAP® Mobility Workstation Use to mount 75x75mm mounting pattern devices Capsule Neuron with Mini Dock Capsule Neuron 2

(1) 1/8” Hex Wrench (1) 4mm Hex Wrench (2) M6 x 20 BHSCS

(4) M4 x 14 PHMS

(4) M4 x 10 PHMS

DU-GEM-0020-02 Rev B 12/9/14 Page 2 of 4 gcx.com | (800) 228-2555 | +1 (707) 773-1100 | Fax +1 (707) 773-1180 GCX European Office |+31(0) 88 627 2600 | Fax +31 (0) 88 627 2609 GCX Taiwan | (886) 2 2298 2842 |Fax (886) 2 8990 3052

3

(4) M4 x 14 PHMS

(4) M4 x 10 PHMS

Capsule Neuron with Mini Dock

Capsule Neuron 2

( (2) M6 x 12 )

1

4mm

2X

(2) M6 x 20

4mm

2

2X

DU-GEM-0020-02 Rev B 12/9/14 Page 3 of 4 gcx.com | (800) 228-2555 | +1 (707) 773-1100 | Fax +1 (707) 773-1180 GCX European Office |+31(0) 88 627 2600 | Fax +31 (0) 88 627 2609 GCX Taiwan | (886) 2 2298 2842 |Fax (886) 2 8990 3052

6

1/8”

8

4 5

4mm

3X

7

4mm

3X

DU-GEM-0020-02 Rev B 12/9/14 Page 4 of 4 gcx.com | (800) 228-2555 | +1 (707) 773-1100 | Fax +1 (707) 773-1180 GCX European Office |+31(0) 88 627 2600 | Fax +31 (0) 88 627 2609 GCX Taiwan | (886) 2 2298 2842 |Fax (886) 2 8990 3052

This roll stand and its accessories may be cleaned with most mild, non-abrasive solutions commonly used in the hospital environment. The below listed agents are known to be compatible with this product. This list is not exhaustive and other non-listed agents may also be found compatible for use. Water Mild Soap Solutions Hydrogen Peroxide Solution, 3% Iodine Solutions Bleach Solutions, 10% Isopropyl Alcohol Solutions, 70%, 91% QUAT Disinfectants Cavicide® Cidex OPA® Cidex Plus® Formula 409® Kleenaseptic® Lysol® Disinfectant Sagrotan® Sani-Cloth® HB Sporicidin® Surfanios Vesphene® Virex® II 256

The surface finish of this roll stand and its accessories may be permanently damaged by strong chemicals, solvents or abrasives. These listed materials are known to cause probable damage to this product and should not be used. This list is not exhaustive and other non-listed agents may also be found non-suitable for use. Acetone Trichloroethylene Steel wool or other abrasive material Ethanol 100% Oxivir® TB Never submerge the product. Damage caused by the use of unapproved substances or processes will not be warranted.