tpr€281, 80€°c, dn€16€iso-kf - hakuto-vacuum.jp · technical data tpr€281, 80€°c,...
TRANSCRIPT
TPR 281, 80 °C, DN 16 ISO-KF
Flange size: DN 16 ISO-KF
Compact and rugged
Maximum pressure refers to inert gases
Similar Image
Dimensions
Technical Data TPR 281, 80 °C, DN 16 ISO-KF
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature For corrosive mediaFeedthrough GlassFilament NickelFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 ISO-KFOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of reading
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 281, 80 °C, DN 16 ISO-KF
Response time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 1.3 cm³Weight 80 g
Order number
TPR 281 PT R21 950
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -TVacuum accessoriesCentering ring with metal mesh-fine filter,pore size 4 m, FPM/stainless steel PT 120 132 -TCentering ring with protection filter,pore size 20 m, FPM/stainless steel PF 117 216 -T
www.pfeiffer-vacuum.com Page 3
TPR 281, 80 °C, DN 16 CF-R
Flange size: DN 16 CF-R
Compact and rugged
Maximum pressure refers to inert gases
Similar Image
Dimensions
Technical Data TPR 281, 80 °C, DN 16 CF-R
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature For corrosive mediaFeedthrough GlassFilament NickelFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 CF-ROutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of reading
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 281, 80 °C, DN 16 CF-R
Response time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 1.5 cm³Weight 100 g
Order number
TPR 281 PT R21 951
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T
www.pfeiffer-vacuum.com Page 3
TPR 281, 250 °C, DN 16 ISO-KF
Flange size: DN 16 ISO-KF
With extra-long case
Compact and rugged
Maximum pressure refers to inert gases
Similar Image
Dimensions
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 281, 250 °C, DN 16 ISO-KF
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 250 °CFeature For corrosive mediaFeedthrough GlassFilament NickelFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 ISO-KFOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 10 cm³Weight 130 g
Order number
TPR 281 PT R21 960
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -TVacuum accessoriesCentering ring with metal mesh-fine filter,pore size 4 m, FPM/stainless steel PT 120 132 -TCentering ring with protection filter,pore size 20 m, FPM/stainless steel PF 117 216 -T
www.pfeiffer-vacuum.com Page 3
TPR 281, 250 °C, DN 16 CF-R
Flange size: DN 16 CF-R
Measurement range from 5 · 10-4 to 1000 hPa
With extra-long case
Compact and rugged
Fast, stable measurement
For corrosive media
Maximum pressure refers to inert gases
Similar Image
Dimensions
www.pfeiffer-vacuum.com Page 2
Technical Data TPR 281, 250 °C, DN 16 CF-R
Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 250 °CFeature For corrosive mediaFeedthrough GlassFilament NickelFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar
Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Method of measurement PiraniNominal diameter DN 16 CF-ROutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 10 cm³Weight 140 g
Order number
TPR 281 PT R21 961
Accessories
AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T
www.pfeiffer-vacuum.com Page 3