tpx series: plate & frame heat exchangersheat transfer and tanks taco tpx series plate and frame...

4
Heat Transfer and Tanks Taco TPX Series Plate and Frame Heat Exchangers are ASME designed and constructed. Computerized product selection helps you choose the heat exchanger that's just right for your application. Their compact size and ease of servicing, coupled with Taco dependability, make the TPX Series the perfect choice. TPX Series: Plate & Frame Heat Exchangers ©Taco Catalog # Supersedes: New Effective Date: Printed in USA WATER CIRCULATION,FLOW CONTROL,AIR ELIMINATION,FLOW MEASUREMENT/BALANCING,ELECTRONIC CONTROLS ®

Upload: others

Post on 21-Mar-2020

51 views

Category:

Documents


0 download

TRANSCRIPT

Heat Transfer and Tanks

Taco TPX Series Plate and Frame Heat Exchangers are ASME designed and constructed. Computerizedproduct selection helps you choose the heat exchanger that's just right for your application. Their compact size and ease of servicing, coupled with Taco dependability, make the TPX Series the perfectchoice.

TPX Series: Plate & Frame Heat Exchangers

©Taco Catalog #Supersedes: New

Effective Date:Printed in USA

WATER CIRCULATION, FLOW CONTROL,AIR ELIMINATION, FLOW MEASUREMENT/BALANCING, ELECTRONIC CONTROLS

®

Furnish a TACO plate and frame heatexchanger to meet the operating condi-tions as indicated in the attached schedule.

The exchanger shall be designed,constructed and tested in accordance withSection VIII, Division I of the ASMEPressure Vessel Code, and shall be codestamped. Pressure vessels provided forinstallation in Canada shall be marked withthe appropriate CRN number.

Preference will be given to single passdesigns with all system connections to belocated on the face of the fixed cover plate.

The plate and frame heat exchanger’s fixedand movable covers shall be designed toprovide sufficient uniform thickness towithstand all loading. Stiffeners and welded reinforcements shall not be permitted. Any plate within the exchang-er’s plate pack shall be replaceable withoutthe need to remove other plates.

A roller bearing shall be provided on themovable cover for all units greater than 50inches in height. The frame assembly shall

be of bolted construction. Welding to thepressure retaining components is not permitted.The frame assembly design shallallow the addition of a minimum of 10 percent additional plates.

Each plate shall be pressed from ahomogenous metal sheet in one step. Allplates shall be marked to identify platematerial, heat number, thickness and rawplate supplier. Each plate channel shall bedesigned to allow full design pressure onone side with no pressure on the adjacentplate channel. Contact between adjacentplates is required to optimize structuralintegrity and elimination of vibration.

Gaskets shall be designed to indicateleakage across the sealing gaskets prior tothe intermixing of fluids.

The suspension and guidance method inthe design of the plates, frame, carrying andguide bars shall mechanically align theplates during tightening. Gasket surfacesshall be used for sealing not for platealignment.

The carrying and guide bar surfaces incontact with the plate pack shall be stain-less steel. All other carbon steel surfacesexcept the bolts shall be epoxy painted.

A stainless steel OSHA shroud shall be provided.

A comprehensive operations andmaintenance manual and ASME nameplateshall be attached on the face of the fixedcover.

Connections less than or equal to 2-inchshall be NPT type. Connections largerthan 2-inch shall be of studded port design.Each studded port shall be lined with afluid compatible material to preventprocess fluid from coming in contact withthe painted cover.

The exchanger shall be hydrostaticly testedin accordance with the requirements of theASME Code Section VIII Div 1, para. UG-99.

A computer generated submittal and specifica-tion sheet indicating the criteria used in eachunit’s selection shall be submitted for approval.

Applications Economizer free cooling; ground source heat pumps; ground water cooling; water source heat pump freeze protectionisolation; campus (district) heating and cooling; industrial processes; and pressure zone isolation.

SupportColumn

SupportFoot

Guide Bar

Tightening Nut

Tightening BoltLock Washer

Bearing BoxShroud

Frame Foot

Fixed Cover

Plate Pack

Carry BarGasket

InspectionCover

Roller Assembly Movable Cover

Stud Bolt

TACO Plate and Frame Heat Exchanger Specification

Gasketed Plate Heat Exchangers

TPX34L 50 30 1' 9" 0' 8" 2' 0" 200 1"

TPX161H 250 400 3' 1" 1' 1" 3' 8" 1,000 2"

TPX151L 250 400 3' 1" 1' 1" 3' 8" 1,000 2"

TPX237L 1,000 750 3' 6" 1' 6" 7' 9" 2,000 4"

TPX258H 1,000 1,000 3' 6" 1' 6" 7' 9" 2,000 4"

TPX667H 2,000 4,500 6' 7" 2' 2" 11' 6" 10,000 6"

TPX807 H 2,000 5,000 6' 10" 2' 4" 15' 8" 10,000 6"

TPX915L 4,000 5,500 7' 4" 2' 6" 16' 2" 14,000 8"

TPX1152H 4,000 7,000 7' 6" 2' 10" 13' 5" 17,000 8"

TPX1615H 6,000 11,000 10' 5" 3' 1" 13' 5" 27,000 10"

TPX1981H 12,000 15,000 10' 5" 3' 10" 17' 6" 31,000 14" (D)

(D) Double Wall

TPX34LD 50 30 1' 9" 0' 8" 2' 0" 200 1"

TPX151LD 250 300 3' 1" 1' 1" 3' 8" 1,000 2"

TPX258HD 1,000 1,000 3' 6" 1' 6" 7' 9" 3,000 4"

Glue-Free GasketsGlue-free clip on gaskets offer fastand easy gasket replacement on site.

Glued GasketsGlued gaskets offer increased reliability,especially for repeated openings..

Maximum MaximumFlowrate Surface Area Maximum Maximum Dry Weight Conn.

Unit Type (GPM) (Sq. Ft.) Height Width Length (Lbs.) Size

Frame designs and operating pressuresfor the above products.

L2 100 PSI H1 300 PSIM2 150 PSI H3 400 PSI

MaterialsPlates:304 SS316 SSTitanium

GasketsNitrile EPDM• Standard • Standard• High Temperature • High Performance• Hydrogenated • High TemperatureVitonPTFE

Other Plate Designs and Gasket Materials are Available Upon Request

Taco Incorporated, 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 / (905) 564-9422 / Fax (905) 564-9436

Internet: taco-hvac.com

WATER CIRCULATION, FLOW CONTROL,AIR ELIMINATION, FLOW MEASUREMENT/BALANCING, ELECTRONIC CONTROLS

Bold areas should be completed to provide design calculations.

TACO Plate Heat Exchanger Specification Sheet

1. Customer Your Job No.

2. Address Your Reference No.

Our Inquiry No.

3. Plant Location Date

4. Service of Unit Item No.

5. Type No. of Exch. Rq’d Connected In

6. Total Surface ft.2 Surface/Exch. ft.2

Guaranteed Performance Hot Side Cold Side

7. Fluid Circulated

8. Total Fluid Entering

9. Vapor

10. Liquid

11. Steam

12. Non-Condensables

13. Fluid Vaporized or Condensed*

14. Steam Condensed

15. Physical Property Data Temp. ºF

16. Specific Heat BTU/lb. ºF

17. Specific Gravity

18. Thermal Conductivity BTU/lb. ft.ºF

19. Viscosity Cp

20. Latent Heat Vapors BTU/lb.

21. Non-Newtonian k/n

22. Molecular Weight

23. Temperature In ºF

24. Temperature Out ºF

25. Operating Pressure Psig

26. Max.Allow. Pressure Drop Psig

27. Thermal Margin %

28. Heat Exchanged: BTU/Hr. LMTD: ºF*For two-phase duties, also provide either condensing curve or vapor pressure data.

Construction

29. Design Pressure Psig Test Pressure: Psig

30. Design Temperature ºF Connection Material:

31. Material - Gaskets: Covers Material – Carbon Steel: SA-

32. Material - Plates: Tightening Bolt Material:

33. Carrying Bar Material: Guide Bar Material:

Remarks:

/ / / /